--- license: mit library_name: pytorch tags: - battery - state-of-health - degradation-forecasting - time-series - state-space-model --- # DecayFormer Trained weights of **DecayFormer**, a compact hybrid state space / attention model that forecasts a battery cell's full state of health (SOH) trajectory from its first 100 cycles, for all 22 aging-condition-exclusive folds of the BatteryLife benchmark as defined by BatteryMFormer. One model per fold; 791,529 parameters. Code, reproducibility notebooks and documentation: [github.com/ShreyPatel1311/DecayFormer](https://github.com/ShreyPatel1311/DecayFormer). License: MIT. ## Results of these weights Test MAPE (%) from BatteryMFormer's released evaluation (`evaluate_model.py`, fp16), on each fold's own test set. Mean ± std across folds: | Domain | Folds | Test MAPE | |---|---|---| | Li-ion | 3 | 2.281 ± 0.089 | | Zn-ion | 3 | 6.814 ± 0.540 | | Na-ion | 12 | 0.926 ± 0.282 | | CALB | 4 | 2.783 ± 2.200 | | Fold | Test MAPE | Early-stopping patience | |---|---|---| | `Li-ion/seed2021` | 2.375 | 30 | | `Li-ion/seed42` | 2.197 | 30 | | `Li-ion/seed2024` | 2.272 | 30 | | `Zn-ion/seed2021` | 6.248 | 30 | | `Zn-ion/seed42` | 6.869 | 30 | | `Zn-ion/seed2024` | 7.324 | 30 | | `Na-ion/cond400` | 0.660 | 30 | | `Na-ion/cond401` | 1.346 | 50 | | `Na-ion/cond402` | 0.843 | 50 | | `Na-ion/cond403` | 0.834 | 30 | | `Na-ion/cond404` | 1.001 | 30 | | `Na-ion/cond405` | 0.831 | 30 | | `Na-ion/cond406` | 0.487 | 30 | | `Na-ion/cond407` | 1.463 | 30 | | `Na-ion/cond408` | 1.006 | 30 | | `Na-ion/cond409` | 1.138 | 30 | | `Na-ion/cond410` | 0.721 | 30 | | `Na-ion/cond411` | 0.785 | 30 | | `CALB/cond396` | 5.209 | 30 | | `CALB/cond397` | 0.946 | 30 | | `CALB/cond398` | 0.893 | 30 | | `CALB/cond399` | 4.082 | 30 | ## Training configuration All 22 models share one configuration: d_model 96, 3 encoder blocks, 4 attention heads, dropout 0.1; AdamW at learning rate 5e-4 with a constant schedule; batch 128 (one GPU, equal to BatteryMFormer's 2 x 64 recipe); up to 300 epochs with early stopping on validation MAPE; fp16; each fold's own seed (2021, 42 or 2024). The only per-fold difference is early-stopping patience: 50 for Na-ion cond401 and cond402, 30 for every other fold. Training ran inside BatteryMFormer's released pipeline (commit `febe174`) on BatteryLife v11, so data, targets, training loop and evaluation are common to all models compared with it. ## Files ``` config.json architecture (DecayFormerConfig) // model.safetensors weights, saved from BatteryMFormer's pipeline (keys prefixed "net.") args.json training arguments in that pipeline label_scaler label scaler expected by that pipeline's data loader ``` Domains: `Li-ion` (seed2021, seed42, seed2024), `Zn-ion` (seed2021, seed42, seed2024), `Na-ion` (cond400 to cond411), `CALB` (cond396 to cond399). ## Usage ```python from decayformer import load_fold # pip install from the DecayFormer repository model = load_fold("Na-ion/cond400") # x [B, 100, 300, 4] curves, mask [B, 100], soh [B, 100, 1], cycle_feats [B, 100, 2] trajectory = model(x, mask, soh, cycle_feats) # [B, 5000] normalised SOH ``` To reproduce the table above, follow the notebooks in the repository, which evaluate these weights with BatteryMFormer's own pipeline.