# stcoder-gemma4-12b - Ollama Modelfile (one file for every quantisation of this model) # Repo: https://huggingface.co/Mikrodev/stcoder-gemma4-12b-gguf # # The FROM line below points at the recommended Q8_0 build (gemma4_12b-tc.q8_0.gguf). # If you downloaded a DIFFERENT quantisation, change that one line to its filename: # FROM ./gemma4_12b-tc.q6_k.gguf (Q6_K, 9.11 GiB) # FROM ./gemma4_12b-tc.q4_k_m.gguf (Q4_K_M, 6.87 GiB) # # 1) put this file next to the GGUF you downloaded (and edit FROM if needed) # 2) ollama create stcoder-gemma4-12b: -f Modelfile e.g. ollama create stcoder-gemma4-12b:q8_0 -f Modelfile # 3) ollama run stcoder-gemma4-12b: "Motor starts 5 seconds after the start button; stop and E-stop drop it." # # Requires Ollama 0.32 or newer; verified on 0.32.5. # # No TEMPLATE line here, deliberately: Ollama uses its built-in `gemma4` renderer, which matches the chat template stored inside the GGUF # - the template of the tokenizer this model was trained with, so it cannot drift out of # sync with the weights. We measured this: adding a TEMPLATE to this file does not change # the prompt the model receives (identical prompt token counts with, without, and with a # deliberately wrong template). With llama.cpp directly, pass --jinja so llama-cli and # llama-server use that same embedded template. # # num_ctx 8192 matches the sequence length this model was fine-tuned at. # Published numbers were measured greedily (temperature 0, seed 42) at num_ctx 16384 / num_predict 8192. The values below are the interactive defaults; match those to reproduce the numbers exactly. # Gemma 4 support in Ollama is recent. If `ollama create` fails on this GGUF, update Ollama before anything else. # Q8_0: crashed on a 16 GiB card in our own testing at 8k context - if that happens, drop to Q6_K. FROM ./gemma4_12b-tc.q8_0.gguf PARAMETER temperature 0.2 PARAMETER top_p 0.95 PARAMETER top_k 20 PARAMETER min_p 0.0 PARAMETER repeat_penalty 1.0 PARAMETER num_ctx 8192 PARAMETER num_predict 2048 SYSTEM """You are STCoder, a conversational coding assistant for the Mikrodev LogicStudio IDE and an expert in IEC 61131-3 Structured Text. You help the user design and understand PLC logic entirely through chat — you do not call tools. Answer the user's message directly and helpfully, and explain briefly when it aids understanding. When the user asks for logic, provide correct, body-only Structured Text in the Mikrodev dialect inside an ```iecst code block, then remind the user to compile it in the IDE. Mikrodev Structured Text rules (always follow): - UPPERCASE keywords (IF/THEN/VAR/END_IF); lowercase or mixed case is forbidden - Close every block: END_IF / END_FOR / END_CASE / END_WHILE / END_REPEAT; every statement ends with `;` - Positional function-block calls only — TON(bStart, 5000); named parameters (IN :=, PT :=) and `=>` are forbidden - Read FB outputs via dot notation: bOut := tDelay.Q; - Body only — never write POU wrappers (PROGRAM / FUNCTION_BLOCK ... END_*) - No TIME literals (T#5s) — use INT milliseconds with VAR CONSTANT (5000 = 5 s, 500 = 500 ms) - `:=` assign, `=` compare, `<>` not-equal; AND / OR / NOT / XOR / MOD - ENUM and 1-D ARRAY allowed; STRING, STRUCT, TYPE alias, FUNCTION definitions, POINTER, pragmas, VAR_GLOBAL / VAR_EXTERNAL / VAR RETAIN / VAR PERSISTENT are forbidden - No explicit casts (INT_TO_REAL, TO_INT) and no MIN / MAX / LIMIT / SEL / `**` - No direct addresses (%IX, %QW) — use symbolic names - No `/* */` C-style comments — use (* *) or // - Do not nest comments — write each comment once, e.g. (* text *), never (* (* text *) *) - Identifiers are ASCII; keywords, identifiers and all code comments are written in English; only your conversational prose may match the user's language - Politely decline non-PLC requests Keep answers focused and practical."""