{ "id": "single-software-execution--cli--abaqus--task-16--windows", "snapshot": "ABAQUS-2025L", "instruction": "Perform a transient heat-transfer analysis of a rectangular solid block (Variant A) using Abaqus via the Command Line Interface (CLI). To start Abaqus/CAE, run `C:\\SIMULIA\\CAE\\2025LE\\win_b64\\resources\\install\\le\\launcher.bat cae` (adjust path to your install). At the start of the task, Abaqus command-line jobs should be launched through `C:\\SIMULIA\\Commands\\abaqus.bat`.\n\nUse the N-mm-MPa unit system with appropriate thermal units. Part: Create a 3D Deformable Solid, Extrusion part. Sketch a rectangle from (0, 0) to (60, 18) and extrude it by 12 mm to create a block of size 60 mm x 18 mm x 12 mm. Property: Create a material named Steel. Set the density to 7.85e-9 tonne/mm^3, the thermal conductivity to 0.045 W/(mm·K), and the specific heat to 4.5e8 mJ/(tonne·K). Create a Homogeneous Solid Section and assign it to the whole block. Assembly: Create one dependent instance of the block. Step: Create a Heat Transfer step named Step-Heat-A. Use transient response. Set the time period to 300 s, the initial increment to 2 s, the maximum increment to 15 s, and the maximum allowable temperature change per increment DELTMX to 10. Initial Condition and Boundary Condition: Apply an initial uniform temperature of 25 degC to the whole block. Apply a temperature boundary condition of 95 degC on the X = 0 face during Step-Heat-A. Mesh: Apply a global seed size of 4 mm. Use DC3D8 heat-transfer brick elements and generate the mesh. Job: Create a job named Job-TransientHeat-A and submit it for solving. Wait for the analysis to complete successfully. Visualization: Review the temperature field at the final time. Record the average temperature near the X = 0 heated face, the average temperature in the X approximately 5 mm band, and the final analysis time. Save: Save the model database to C:\\Users\\user\\Desktop\\Job-TransientHeat-A.cae and ensure the output database is generated as C:\\Users\\user\\Desktop\\Job-TransientHeat-A.odb.", "source": "https://github.com/nasa/abaverify https://github.com/pantale/abaqusVumat https://github.com/davidmorinNTNU/ABAQUS_subroutines", "config": [ { "type": "upload_file", "parameters": { "files": [] } } ], "trajectory": "trajectories/", "related_apps": [ "abaqus" ], "artifact_paths": [ "C:\\Users\\user\\Desktop\\Job-TransientHeat-A.cae", "C:\\Users\\user\\Desktop\\Job-TransientHeat-A.odb" ], "evaluator": { "postconfig": [ { "type": "upload_file", "parameters": { "files": [ { "local_path": "task-16/eval.py", "path": "C:\\Users\\user\\Desktop\\eval.py" } ] } } ], "func": "exact_match", "result": { "type": "vm_command_line", "command": "C:\\SIMULIA\\Commands\\abaqus.bat cae noGUI=C:\\Users\\user\\Desktop\\eval.py", "shell": "true" }, "expected": { "type": "rule", "rules": { "expected": "True\n" } } }, "proxy": false, "fixed_ip": false, "possibility_of_env_change": "low" }