{ "id": "single-software-execution--cli--openstudio--task-15--ubuntu", "snapshot": "OpenStudio-1.11.0", "instruction": "Organize /home/user/Desktop/init.osm in the opened OpenStudio application using its CLI/API automation interface, and save the updated model as /home/user/Desktop/result.osm. For this workflow, use `/usr/local/openstudioapplication-1.11.0-rc2/bin/openstudio` for OpenStudio CLI or API automation when working on `init.osm`. Do not directly create, rewrite, patch, copy, or post-process OSM text outside the OpenStudio environment. The current model is a single-story showroom with the south side as the primary display face and the east and west sides as secondary facades. The architect wants the simple massing retained while the envelope and glazing performance are upgraded and summer direct sun is controlled with continuous south shading. Complete low-heat-transfer wall, roof, slab, and high-performance glazing constructions, along with showroom loads, outdoor air, infiltration, and comfort settings. Deliver only the updated OpenStudio model file; object handles, serialization order, and automatically generated metadata may vary naturally. The completed model must meet the following exact specification (SI units; geometry coordinates and lengths are metres; areas are square metres; names are exact): {\"building\":\"CLI High Performance Showroom\",\"stories\":[{\"name\":\"01_FACADE\",\"z\":0}],\"spaces\":[{\"name\":\"T15-SHOWROOM\",\"zone\":\"T15-SHOWROOM Zone\",\"x0\":0,\"y0\":0,\"x1\":20,\"y1\":12,\"z0\":0,\"h\":3.6,\"story\":\"01_FACADE\",\"space_type\":\"TASK15 Showroom Type\",\"heat\":20,\"cool\":25,\"ideal\":true}],\"constant_schedules\":{\"TASK15 Occupancy\":0.65,\"TASK15 Loads\":0.8,\"TASK15 OA Schedule\":1,\"TASK15 Infiltration\":1},\"space_types\":{\"TASK15 Showroom Type\":{\"people\":0.045,\"people_schedule\":\"TASK15 Occupancy\",\"lights\":7.5,\"lights_schedule\":\"TASK15 Loads\",\"equipment\":8,\"equipment_schedule\":\"TASK15 Loads\"}},\"windows\":[{\"space\":\"T15-SHOWROOM\",\"wall\":\"south\",\"start\":4,\"end\":16,\"sill\":0.8,\"head\":2.6,\"name\":\"T15-SHOWROOM South FixedWindow\"},{\"space\":\"T15-SHOWROOM\",\"wall\":\"north\",\"start\":6,\"end\":14,\"sill\":1.1,\"head\":2.3,\"name\":\"T15-SHOWROOM North FixedWindow\"},{\"space\":\"T15-SHOWROOM\",\"wall\":\"east\",\"start\":3,\"end\":8,\"sill\":1,\"head\":2.5,\"name\":\"T15-SHOWROOM East FixedWindow\"},{\"space\":\"T15-SHOWROOM\",\"wall\":\"west\",\"start\":4,\"end\":9,\"sill\":1,\"head\":2.5,\"name\":\"T15-SHOWROOM West FixedWindow\"}],\"shading\":[{\"name\":\"TASK15 South Continuous Overhang\",\"x0\":3.5,\"x1\":16.5,\"y0\":-1.1,\"y1\":0,\"z\":3}],\"infiltration\":{\"all\":{\"flow_per_exterior_area\":0.00022,\"schedule\":\"TASK15 Infiltration\"}},\"outdoor_air\":{\"all\":{\"per_person\":0.0075,\"per_floor_area\":0.00045,\"schedule\":\"TASK15 OA Schedule\"}},\"constructions\":{\"wall\":{\"name\":\"TASK15 Low-U Wall Construction\",\"layers\":[{\"name\":\"TASK15 Interior Board\",\"thickness\":0.013,\"conductivity\":0.16,\"density\":800,\"specific_heat\":1090},{\"name\":\"TASK15 Mineral Wool\",\"thickness\":0.18,\"conductivity\":0.036,\"density\":40,\"specific_heat\":840}]},\"roof\":{\"name\":\"TASK15 High-R Roof Construction\",\"layers\":[{\"name\":\"TASK15 Roof Deck\",\"thickness\":0.02,\"conductivity\":0.2,\"density\":900,\"specific_heat\":1200},{\"name\":\"TASK15 Roof Polyiso\",\"thickness\":0.2,\"conductivity\":0.03,\"density\":32,\"specific_heat\":1400}]},\"floor\":{\"name\":\"TASK15 Ground Slab Construction\",\"layers\":[{\"name\":\"TASK15 Heavy Slab\",\"thickness\":0.18,\"conductivity\":1.55,\"density\":2300,\"specific_heat\":880}]},\"window\":{\"name\":\"TASK15 Triple Glazing Construction\",\"u_factor\":1.2,\"shgc\":0.25,\"vt\":0.48}},\"metrics\":{\"bbox\":[20,12,3.6],\"floor_area\":240,\"exterior_wall_area\":230.4,\"surface_count\":6,\"space_count\":1,\"zone_count\":1,\"story_count\":1,\"window_count\":4,\"window_area\":46.2,\"shading_count\":1,\"shading_area\":14.3,\"paired_surface_count\":0,\"ground_floor_count\":1}}. Assign the named wall, roof, floor, and glazing constructions to the corresponding actual exterior surfaces and windows; creating unassigned construction objects is not sufficient.", "source": "OpenStudio CLI / SDK automation interface", "config": [ { "type": "upload_file", "parameters": { "files": [ { "local_path": "task-15/init_file/init.osm", "path": "/home/user/Desktop/init.osm" } ] } }, { "type": "launch", "parameters": { "command": [ "OpenStudioApp", "/home/user/Desktop/init.osm" ] } } ], "trajectory": "trajectories/", "related_apps": [ "openstudio" ], "artifact_paths": [ "/home/user/Desktop/result.osm" ], "evaluator": { "postconfig": [ { "type": "upload_file", "parameters": { "files": [ { "local_path": "task-15/eval.py", "path": "/home/user/Desktop/eval.py" } ] } } ], "func": "exact_match", "result": { "type": "vm_command_line", "command": "python3 /home/user/Desktop/eval.py", "shell": "true" }, "expected": { "type": "rule", "rules": { "expected": "True\n" } } }, "proxy": false, "fixed_ip": false, "possibility_of_env_change": "low" }