{ "trajectory_id": "task_5f3905bf_reference", "world_id": "task_5f3905bf", "task_id": "task_5f3905bf", "source": "ground_truth", "records": [ { "kind": "tool_exchange", "call": { "call_id": "call_1", "turn_id": "turn_1", "command": { "target": "session", "function": "get_device_tools", "parameters": { "device_id": "external_power_supply_1" } } }, "result": { "call_id": "call_1", "turn_id": "turn_1", "sequence": 1, "status": "success", "code": "[PASS]", "data": { "device_id": "external_power_supply_1", "tools": [ { "function": "get_output_active", "description": "Return whether external power is currently being supplied.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "output_active" ], "writes": [], "semantics": { "kind": "read", "property": "output_active", "response_key": "output_active" } }, { "function": "get_reserve_percent", "description": "Return the configured external-discharge battery reserve threshold.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "reserve_percent" ], "writes": [], "semantics": { "kind": "read", "property": "reserve_percent", "response_key": "reserve_percent" } }, { "function": "set_reserve_percent", "description": "Set the reserve threshold to an integer from 0 through 100 percent. After assignment, if battery_percent is at or below the new threshold, active output stops, output_power becomes zero, and protection_reason becomes reserve_threshold_reached unless another reported protection reason is already active. If the battery is above the new threshold and the previous reason was reserve_threshold_reached, that reason is cleared to none; output does not restart automatically. Invalid input leaves all state unchanged.", "mutation": true, "parameters_schema": { "type": "object", "properties": { "value": { "type": "integer", "minimum": 0, "maximum": 100, "multipleOf": 1, "description": "Desired reserve threshold in percent.", "examples": [ 20, 30, 50 ] } }, "required": [ "value" ], "additionalProperties": false }, "reads": [ "battery_percent", "output_active", "protection_reason" ], "writes": [ "reserve_percent", "output_active", "output_power", "protection_reason" ], "semantics": { "kind": "set", "property": "reserve_percent", "parameter": "value" } }, { "function": "get_output_power", "description": "Return actual measured external output power in watts. Stopped output always reports zero.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "output_power" ], "writes": [], "semantics": { "kind": "read", "property": "output_power", "response_key": "output_power" } }, { "function": "get_load_connected", "description": "Return whether an external electrical load is connected.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "load_connected" ], "writes": [], "semantics": { "kind": "read", "property": "load_connected", "response_key": "load_connected" } }, { "function": "get_battery_percent", "description": "Return the battery percentage currently used for reserve-threshold protection.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "battery_percent" ], "writes": [], "semantics": { "kind": "read", "property": "battery_percent", "response_key": "battery_percent" } }, { "function": "get_load_power_demand", "description": "Return the power currently requested by the connected external load.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "load_power_demand" ], "writes": [], "semantics": { "kind": "read", "property": "load_power_demand", "response_key": "load_power_demand" } }, { "function": "get_protection_reason", "description": "Return the current energy or protection condition blocking external output. A value of none means no energy or protection restriction is active.", "mutation": false, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "protection_reason" ], "writes": [], "semantics": { "kind": "read", "property": "protection_reason", "response_key": "protection_reason" } }, { "function": "report_feedback", "description": "Apply one complete deterministic feedback sample. The supplied connection, battery percentage, and load demand replace their previous values. A supplied protection reason other than none takes priority; otherwise protection_reason becomes reserve_threshold_reached when battery_percent is at or below reserve_percent, or none when it is above the threshold. If output is active, it remains active with output_power equal to load_power_demand only when the load is connected and the resulting protection reason is none. Otherwise output stops and output_power becomes zero. Inactive output remains stopped with zero output power. Invalid input leaves all state unchanged.", "mutation": true, "parameters_schema": { "type": "object", "properties": { "load_connected": { "type": "boolean", "description": "Whether the external load is connected." }, "battery_percent": { "type": "integer", "minimum": 0, "maximum": 100, "multipleOf": 1, "description": "Current battery percentage." }, "load_power_demand": { "type": "integer", "minimum": 0, "maximum": 6000, "multipleOf": 1, "description": "Current connected-load demand in watts." }, "protection_reason": { "type": "string", "enum": [ "none", "insufficient_energy", "overload", "overtemperature", "system_fault" ], "description": "Reported non-reserve protection condition.", "examples": [ "none", "overload", "overtemperature" ] } }, "required": [ "load_connected", "battery_percent", "load_power_demand", "protection_reason" ], "additionalProperties": false }, "reads": [ "output_active", "reserve_percent" ], "writes": [ "load_connected", "battery_percent", "load_power_demand", "protection_reason", "output_active", "output_power" ], "semantics": { "kind": "custom", "reason": "The feedback sample derives reserve protection and conditionally stops output or maps load demand to measured output; this conditional multi-property mapping is not expressible by the standard update semantics." } }, { "function": "start_output", "description": "Start external power output. The action succeeds only while output is stopped, a load is connected, and protection_reason is none. A none protection reason establishes that the latest battery feedback is above reserve_percent and no other reported protection condition is active. On success, output_active becomes true and output_power becomes the current load_power_demand. A rejected request leaves all state unchanged.", "mutation": true, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [ "output_active", "load_connected", "load_power_demand", "protection_reason" ], "writes": [ "output_active", "output_power" ], "semantics": { "kind": "custom", "reason": "Starting requires preconditions and copies the current load_power_demand property into output_power, which cannot be represented by literal or parameter update bindings." } }, { "function": "stop_output", "description": "Stop external power output from any state and set measured output power to zero. Reserve configuration and feedback states are preserved.", "mutation": true, "parameters_schema": { "type": "object", "properties": {}, "required": [], "additionalProperties": false }, "reads": [], "writes": [ "output_active", "output_power" ], "semantics": { "kind": "update", "fields": { "output_active": { "value": false }, "output_power": { "value": 0 } } } } ] }, "mutation_committed": false, "audit_sequence": 1 } }, { "kind": "turn_boundary", "boundary": { "turn_id": "turn_1", "apply_after_turn": true } }, { "kind": "tool_exchange", "call": { "call_id": "call_2", "turn_id": "turn_2", "command": { "target": "external_power_supply_1", "function": "get_reserve_percent", "parameters": {} } }, "result": { "call_id": "call_2", "turn_id": "turn_2", "sequence": 2, "status": "success", "code": "[PASS]", "data": { "reserve_percent": 20 }, "mutation_committed": false, "audit_sequence": 3 } }, { "kind": "tool_exchange", "call": { "call_id": "call_3", "turn_id": "turn_2", "command": { "target": "session", "function": "submit_answer", "parameters": { "value": 20 } } }, "result": { "call_id": "call_3", "turn_id": "turn_2", "sequence": 3, "status": "success", "code": "[PASS]", "data": { "accepted": true, "index": 0 }, "mutation_committed": false, "audit_sequence": 4 } }, { "kind": "tool_exchange", "call": { "call_id": "call_4", "turn_id": "turn_2", "command": { "target": "session", "function": "finish", "parameters": {} } }, "result": { "call_id": "call_4", "turn_id": "turn_2", "sequence": 4, "status": "success", "code": "[PASS]", "data": { "finished": true }, "mutation_committed": false, "audit_sequence": 5 } }, { "kind": "termination", "termination": { "reason": "session_finish", "turn_id": "turn_2", "turn_index": 2, "elapsed_minutes": 0, "limits": { "max_turns": 2, "max_elapsed_minutes": null } } } ] }