{ "engine": "Project Chrono / PyChrono thermal FEA", "engine_version": "9.0.1", "mesher": "Gmsh", "mesher_version": "4.14.1", "experiment": "Protected-face temperature after a fixed heat pulse", "material_density_kg_m3": 900.0, "thermal_conductivity_W_m_K": 400.0, "specific_heat_J_kg_K": 1000.0, "initial_temperature_K": 293.15, "source_power_W": 10.0, "pulse_duration_s": 0.1, "observation_time_s": 0.5, "duration_s": 2.0, "time_step_s": 0.01, "mesh_sizes_mm": [2.0, 1.5], "minimum_baseline_protected_rise_K": 0.1, "required_relative_protected_rise_reduction": 0.3, "minimum_final_energy_rise_fraction": 0.9, "maximum_final_energy_rise_fraction": 1.05, "maximum_relative_mesh_protected_rise_change": 0.05, "maximum_relative_mass_change": 1e-6, "maximum_end_pad_missing_mm3": 0.0001, "maximum_end_pad_excess_mm3": 0.0001, "maximum_envelope_excess_mm3": 0.0001 }