\chapter{Quantum operational completion and its obstruction} \label{ch:quantum} \section{Which quantum experiment is being reversed?} The quantum extension begins with a declared forward experiment and a declared reverse experiment. A unitary propagator, an antiunitary reversal, an apparatus preparation and a record-reading rule are different pieces of that declaration. Confusing them would manufacture an arrow before any information-theoretic calculation. Let $\Theta$ be antiunitary on a finite-dimensional Hilbert space. On Hermitian operators write $J(A)=\Theta A\Theta^{-1}$, and assume $\Theta^2$ is scalar, so $J^2=\mathrm{id}$. This map is real-linear, positive, trace preserving and trace-norm preserving. It is not generally completely positive; it is a comparison operation rather than a universally implementable device. If $\Theta H\Theta^{-1}=H$, then \begin{equation} \Theta e^{-itH}\Theta^{-1}=e^{itH}. \label{eq:quantum-reversible-unitary} \end{equation} Thus microscopic reversibility relates the propagators at $t$ and $-t$. It does not say that a propagator at one fixed positive time commutes with $J$. A reversal-even initial state can acquire a reversal-odd instantaneous observable without contradicting symmetry of its complete, centered history under simultaneous reversal of the time index and $J$. A finite instrument $\{\mathcal I_x\}$ consists of completely positive trace-nonincreasing maps whose sum is trace preserving. A specified instrument sequence has record probabilities \begin{equation} P(x_1,\ldots,x_n)=\operatorname{Tr}\!\left[ \mathcal I^n_{x_n}\mathcal U_n\cdots \mathcal I^1_{x_1}\mathcal U_1(\rho_0)\right]. \label{eq:quantum-record-law} \end{equation} Here each $\mathcal U_k$ may describe a unitary step on a larger system. Adaptive instruments are allowed by indexing each subsequent map by the preceding record. Initial environmental correlations can be retained by keeping the environment in this construction. A physically specified reversed protocol gives another normalized law on the aligned record alphabet. The classical path-pair theorems apply to this pair without assuming Markovian records. One cannot usually combine every possible intervention into one nondisturbing classical path measure. For example, an $X$ measurement on $|+x\rangle$ returns $+$ certainly, whereas an unread $Z$ measurement followed by $X$ gives equal probabilities. Inserting the intervention changes the process seen by the later measurement. Ordinary marginalization of a fixed record law cannot simultaneously describe both experiments while treating that intervention as passive observation. For a finite multitime process, quantum combs or process tensors supply operational functionals on admissible testers; see~\cite{Pollock2018}. Two processes are indistinguishable to a tester class precisely when their difference annihilates the real span of that class. A final density matrix need not encode all those tests. In particular, the trace distance between arbitrarily normalized Choi matrices is not automatically the discrimination norm for constrained adaptive testers. Our state/channel theorem below applies to a specified common quantum encoding or retained quantum output; for every fully specified instrument sequence it also applies through its classical record law. A theorem equating arbitrary process-tensor recovery with an endpoint-state formula is not asserted. \section{The common operational object} Let $\rho,\sigma$ be density matrices representing the aligned forward and reverse alternatives. Define \begin{equation} \mu=\frac{\rho+\sigma}{2},\qquad \Delta=\frac{\rho-\sigma}{2}. \label{eq:quantum-pair} \end{equation} Then $\operatorname{Tr}\mu=1$, $\operatorname{Tr}\Delta=0$ and $-\mu\leq\Delta\leq\mu$. Conversely these conditions reconstruct exactly the ordered state pair $\rho=\mu+\Delta$, $\sigma=\mu-\Delta$. The object is the pair together with its permitted observables and channels; a scalar summary is not substituted for this complete operational data. For a real linear space $V$ of accessible Hermitian observables, absence of an accessible arrow is exactly \begin{equation} \operatorname{Tr}(\Delta A)=0\quad\text{for every }A\in V. \label{eq:quantum-invisibility} \end{equation} For the full Hermitian space it is equivalent to $\rho=\sigma$. Restricted observations can satisfy~\eqref{eq:quantum-invisibility} while the states differ. \begin{proposition}[Optimal direction test] With equal prior probabilities and all two-outcome quantum measurements allowed, \begin{equation} p_{\rm success}=\frac12+\frac14\|\rho-\sigma\|_1 =\frac{1+\|\Delta\|_1}{2}. \label{eq:quantum-helstrom} \end{equation} A common completely positive trace-preserving map cannot increase this success probability. \end{proposition} \begin{proof} A test is an effect $0\leq E\leq I$. Its success probability is $1/2+\operatorname{Tr}[E(\rho-\sigma)]/2$. Write the traceless Hermitian difference as $D_+-D_-$, with orthogonal positive and negative spectral parts. The maximum of $\operatorname{Tr}(ED)$ is $\operatorname{Tr}D_+=\|D\|_1/2$, attained by the positive spectral projector. Any classical decision from a more complicated measurement combines its outcomes into an effect, proving optimality. For Hermitian $D$, $\|D\|_1=\max_{-I\leq A\leq I}\operatorname{Tr}(DA)$. The adjoint of a trace-preserving positive map is unital and positive, so it maps $[-I,I]$ into itself. Therefore $\|\Phi(D)\|_1\leq\|D\|_1$. \end{proof} The condition $\rho\neq\sigma$ describes statistical distinguishability after the physical comparison has been chosen. It does not itself prove that the microscopic laws violate time reversal. Distinct preparations or non-equivalent apparatus protocols can supply the difference. \section{An exact bounded score, with an exact limitation} Compress the Hilbert space to $\operatorname{supp}\mu$. On this support $\mu$ is positive definite, even when $\rho$ or $\sigma$ is singular. Let \begin{equation} \mathcal J_\mu(A)=\frac{\mu A+A\mu}{2},\qquad L=\mathcal J_\mu^{-1}(\Delta). \label{eq:quantum-score} \end{equation} We use $\mathcal J_\mu$ for this Jordan map, distinct from the physical reversal $J$. \begin{proposition}[Score representation and observable projection] The score is Hermitian and $-I\leq L\leq I$. With the real inner product \begin{equation} \langle A,B\rangle_\mu =\frac12\operatorname{Tr}[\mu(AB+BA)], \label{eq:quantum-inner} \end{equation} it represents every observable contrast: $\langle L,A\rangle_\mu=\operatorname{Tr}(\Delta A)$. If $L_V$ is its orthogonal projection onto a real linear observable space $V$, then \begin{equation} \operatorname{Tr}(\mu L^2) =\|L_V\|_\mu^2+\|L-L_V\|_\mu^2. \label{eq:quantum-pythagoras} \end{equation} The pair is invisible to $V$ if and only if $L_V=0$. For $V\subset W$, the visible squared norms differ by $\|L_W-L_V\|_\mu^2$. \end{proposition} \begin{proof} In an eigenbasis of $\mu$, $L_{ij}=2\Delta_{ij}/(\mu_i+\mu_j)$. Equivalently, \begin{equation} \mathcal J_\mu^{-1}(B) =2\int_0^\infty e^{-t\mu}B e^{-t\mu}\,dt. \label{eq:quantum-jordan-inverse} \end{equation} The integral converges, is positive as a map, and sends $\mu$ to $I$. Applying it to $-\mu\leq\Delta\leq\mu$ proves the contraction bound. Cyclicity of trace proves the contrast identity. Also $\langle A,A\rangle_\mu=\operatorname{Tr}(\mu A^2)>0$ unless $A=0$, so ordinary finite-dimensional orthogonal projection applies. Expanding the square and using orthogonality proves both Pythagorean identities and the invisibility criterion. \end{proof} For diagonal states, $L$ is exactly the classical bounded score $(p-q)/(p+q)$. The quantum metric here is the established symmetric-logarithmic-derivative metric at the midpoint of the affine state family $\mu+\theta\Delta$. For an arbitrary linear $V$, orthogonal projection is an analytical operation, not necessarily a realizable positive channel. No such physical interpretation is required by the proposition. \begin{proposition}[Channel loss equals residual plus Schwarz defect] \label{prop:quantum-score-loss} Let $\Phi$ be a quantum channel, $\mu'=\Phi\mu$, $\Delta'=\Phi\Delta$, and $L'=\mathcal J_{\mu'}^{-1}(\Delta')$ on the output support. Set $F(\rho,\sigma)=\operatorname{Tr}(\mu L^2)$. Then \begin{align} F(\rho,\sigma)-F(\Phi\rho,\Phi\sigma) &=\|L-\Phi^*L'\|_\mu^2\notag\\ &\quad+\operatorname{Tr}\mu \left[\Phi^*(L'^2)-(\Phi^*L')^2\right]. \label{eq:quantum-score-loss} \end{align} Both terms are nonnegative. Equality holds precisely when $L=\Phi^*L'$ and $\Phi^*(L'^2)=(\Phi^*L')^2$ on the compressed input support. \end{proposition} \begin{proof} Every Kraus operator maps $\operatorname{supp}\mu$ into $\operatorname{supp}\mu'$, so the compressed channel remains trace preserving and its adjoint unital. The contrast identity gives \[ \langle L,\Phi^*L'\rangle_\mu =\operatorname{Tr}(\Delta'L') =\operatorname{Tr}(\mu'L'^2)=F(\Phi\rho,\Phi\sigma). \] Moreover $\operatorname{Tr}\mu\Phi^*(L'^2)=F(\Phi\rho,\Phi\sigma)$. Expanding the squared norm on the right of~\eqref{eq:quantum-score-loss} proves the equality. The Schwarz inequality for the unital completely positive adjoint gives positivity of the matrix in brackets. A positive matrix with zero expectation under faithful $\mu$ vanishes on that support. Together with positive definiteness of~\eqref{eq:quantum-inner}, this proves the equality criterion. \end{proof} For restriction to a subalgebra the adjoint inclusion is multiplicative, so the Schwarz defect vanishes. For a noisy channel it need not vanish. More significantly, zero total score loss is weaker than recoverability. \begin{example}[Zero score loss without recovery] \label{ex:quantum-score-counterexample} Let $X,Z$ be Pauli matrices, $r,a>0$ and $r^2+a^2<1$. Define \begin{equation} \rho_\pm=\frac{I+rX\pm aZ}{2}, \qquad \Phi(A)=\text{$Z$-basis dephasing of }A. \label{eq:quantum-counterexample} \end{equation} Both input states are faithful. Their midpoint is $(I+rX)/2$ and their half-difference is $aZ/2$. Since $XZ+ZX=0$, the score is $L=aZ$, before and after $\Phi$. Consequently $F_{\rm in}=F_{\rm out}=a^2$. Equal-prior trace-distance discrimination is also preserved. Nevertheless there is no recovery channel for both states. If one existed, let $\tau_j$ be its output on $|j\rangle\langle j|$. Adding and subtracting the two recovery equations gives \[ \tau_0+\tau_1=I+rX,\qquad \tau_0-\tau_1=Z. \] Therefore $\tau_{0,1}=(I+rX\pm Z)/2$, whose smallest eigenvalue is $(1-\sqrt{1+r^2})/2<0$. These cannot be density matrices. \end{example} Thus the classical equality-implies-sufficiency property cannot simply be appended to this quantum score identity. A different common information functional does have an exact recovery criterion, as follows. The general failure of SLD information preservation to imply quantum sufficiency is established prior art~\cite{Gao2023}; our qubit calculation supplies a fully explicit witness for the present pair. \section{The common exact loss law and its recovery criterion} We use the following established finite-dimensional background theorem, with its full support condition. For states $\alpha,\beta$ satisfying $\operatorname{supp}\alpha\subseteq\operatorname{supp}\beta$ and a quantum channel $\Phi$, \[ D(\Phi\alpha\Vert\Phi\beta)\leq D(\alpha\Vert\beta). \] Equality holds exactly when the Petz map based on $\beta$ recovers $\alpha$ as well as $\beta$~\cite{Petz1986,Lindblad1975,Uhlmann1977}. Its inverses are taken on $\operatorname{supp}\Phi\beta$. This is an imported operator-algebraic sufficiency theorem, not claimed as a new proof here. Define the quantum Jensen--Shannon information \begin{equation} J_q(\rho,\sigma) =\frac12D(\rho\Vert\mu)+\frac12D(\sigma\Vert\mu) =S(\mu)-\frac{S(\rho)+S(\sigma)}2. \label{eq:quantum-js} \end{equation} Here $D(\rho\Vert\mu)=\operatorname{Tr}\rho(\log\rho-\log\mu)$, with the usual support convention. The inequalities $\rho,\sigma\leq2\mu$ make these quantities finite regardless of singular component states. \begin{theorem}[F: common operational structure] \label{thm:F} For a finite-dimensional temporal pair and a common quantum channel $\Phi$: \begin{enumerate} \item There is no accessible arrow exactly when the two states agree on every allowed effect. With all effects available this is equivalent to $\rho=\sigma$, to $\Delta=0$, and to $J_q=0$. \item $0\leq J_q\leq\log2$, and $J_q$ cannot increase under $\Phi$. \item Let $V:A\to B\otimes E$ be a Stinespring isometry for $\Phi$. For \[ \omega_{CA}=\tfrac12|0\rangle\langle0|\otimes\rho +\tfrac12|1\rangle\langle1|\otimes\sigma \] and its isometric image $\omega_{CBE}$, \begin{equation} J_q(\rho,\sigma)-J_q(\Phi\rho,\Phi\sigma) =I(C:E\mid B)_\omega. \label{eq:quantum-js-loss} \end{equation} \item Equality under $\Phi$ holds if and only if a single quantum channel recovers both states. The Petz map based on their mixture suffices: \begin{equation} \mathcal R_{\mu,\Phi}(X)=\mu^{1/2}\Phi^*\!\left[ (\Phi\mu)^{-1/2}X(\Phi\mu)^{-1/2}\right]\mu^{1/2}. \label{eq:quantum-petz} \end{equation} \item For commuting diagonal states and classical stochastic channels these statements reduce to classical label-information, conditional-information and sufficiency identities. Exact physical reduction of an arbitrary pair to a finite classical register with recovery is possible if and only if the states commute. \end{enumerate} \end{theorem} \begin{proof} Effects span the Hermitian operators, proving the first operational characterization. Positivity of relative entropy and its equality case prove $J_q\geq0$ with equality precisely when $\rho=\sigma$. Operator monotonicity of the logarithm and $\mu\geq\rho/2$ give $D(\rho\Vert\mu)\leq\log2$; the same holds for $\sigma$. Apply relative-entropy data processing to the two terms in~\eqref{eq:quantum-js} to prove monotonicity. For the classical direction register $C$, direct evaluation of the block-diagonal entropy gives $I(C:A)=J_q(\rho,\sigma)$. An isometry preserves the relevant entropies, so $I(C:BE)=I(C:A)$. The entropy chain rule yields \[ I(C:BE)-I(C:B) =S(CB)+S(BE)-S(B)-S(CBE)=I(C:E\mid B). \] This proves~\eqref{eq:quantum-js-loss}; its nonnegativity is strong subadditivity, equivalently the data-processing result already used. A zero Jensen--Shannon loss is the average of two nonnegative relative-entropy losses, so both must vanish. Apply the stated Petz theorem to each with the same reference $\mu$. This produces the same map~\eqref{eq:quantum-petz}, recovering both component states. It is trace preserving on $\operatorname{supp}\Phi\mu$ and may be extended to the orthogonal complement by preparing an arbitrary fixed state. Conversely, a recovery channel for both also recovers $\mu$ by linearity. Data processing first for $\Phi$ and then for recovery sandwiches both relative entropies between equal endpoints, forcing equality. For commuting states all displayed traces become sums and the direction register is an ordinary Bernoulli hypothesis label; hence the stated classical reduction follows. The final characterization follows from the finite classicalization proposition proved next. \end{proof} \begin{proposition}[Exact classicalization and commuting states] \label{prop:quantum-classicalization} A finite-outcome measurement channel $M$ and a preparation channel $R$ can satisfy $RM(\rho)=\rho$, $RM(\sigma)=\sigma$ if and only if $[\rho,\sigma]=0$. \end{proposition} \begin{proof} For commuting states, measure a common eigenbasis and prepare its basis vectors. Conversely, let the measurement effects be $E_i$ and the prepared states $\tau_i$. Put $W_{ij}=\operatorname{Tr}(E_i\tau_j)$, a column-stochastic matrix, and $p=M\rho$, $q=M\sigma$. Recovery implies $Wp=p$ and $Wq=q$. The elementary stationary-distribution decomposition of a finite Markov chain writes $p=\sum_k a_k\pi^k$ and $q=\sum_k b_k\pi^k$, where $\pi^k$ is supported on one closed irreducible recurrent class $C_k$. Transient states carry no stationary mass. Define $\omega_k=\sum_{j\in C_k}\pi_j^k\tau_j$ and $E_{C_k}=\sum_{i\in C_k}E_i$. Closure gives \[ \operatorname{Tr}(E_{C_k}\omega_k)=1,\qquad \operatorname{Tr}(E_{C_k}\omega_l)=0\quad(k\ne l). \] Since $0\leq E_{C_k}\leq I$, the support of $\omega_k$ is in its unit eigenspace and the support of $\omega_l$ in its kernel. Thus the $\omega_k$ have orthogonal supports. Finally $\rho=\sum_k a_k\omega_k$ and $\sigma=\sum_k b_k\omega_k$, so the states commute, being proportional within each common orthogonal block. \end{proof} This is a finite measure-and-prepare form of a standard no-broadcasting consequence~\cite{Barnum1996}. It prohibits a classical likelihood experiment that is physically equivalent by measurement and recovery to a noncommuting quantum pair. It does not prohibit the common bounded information law of Theorem~\ref{thm:F}, an operator-valued representation, or classical outcome laws for each specified instrument. For successive channels, Jensen--Shannon losses telescope and each is nonnegative. A quantitative version follows from the established Fawzi--Renner recovery theorem~\cite{FawziRenner2015}. If the loss is $\delta$, there exists a recovery with average component trace-distance error at most $\sqrt{1-e^{-\delta}}$, where trace distance is half the trace norm. Indeed that theorem gives root fidelity at least $e^{-\delta/2}$ for the reconstructed cq state. Block-diagonal fidelity is the average component root fidelity. The trace-distance/fidelity inequality and concavity of $\sqrt{1-x^2}$ give the bound, followed by a channel left inverse of the Stinespring isometry. This is an application of an imported theorem, not a new recovery bound. \subsection{All prior odds characterize recovery along a fixed channel} A stronger known result prevents confusing the counterexample with failure of every testing-based quantum characterization. \begin{theorem}[Imported all-prior preservation criterion~\cite{Jencova2024}] \label{thm:quantum-all-prior} For one specified quantum channel $\Phi$ and any finite-dimensional density matrices $\rho,\sigma$, including singular ones, the following are equivalent: \begin{enumerate} \item $\|\Phi(\rho)-s\Phi(\sigma)\|_1=\|\rho-s\sigma\|_1$ for every $s\geq0$; \item every optimal binary testing error is preserved for every prior probability; \item one channel recovers both $\rho$ and $\sigma$ from their $\Phi$ outputs. \end{enumerate} \end{theorem} The testing equivalence follows from the spectral positive-part argument used in~\eqref{eq:quantum-helstrom}, now applied to weighted priors. Recovery implies norm preservation by contraction in both directions. The converse is the imported sufficiency theorem of Jen\v{c}ov\'{a}, Theorem 4, proved there through an integral representation of relative entropy and Petz recovery; no faithfulness assumption is required. Its assumption that the output pair is already produced by the same specified channel is essential. A comparison of arbitrary quantum pairs by their testing curves is a different channel-existence question. Thus a complete all-prior profile, together with the channel relation, detects sufficiency even though one scalar score or one equal-prior success probability does not. \section{Protocol parity and a quantum artifact budget} The next result transfers the classical even/odd protocol algebra to the real Hermitian operator spaces. Physical interpretation requires a reversal-correct experimental representation as specified at the beginning of the chapter. Let $J_X,J_Y$ be antiunitary-induced involutions and let \begin{equation} \Phi^R=J_Y\Phi J_X,\qquad \Phi_e=\frac{\Phi+\Phi^R}{2},\qquad \Phi_o=\frac{\Phi-\Phi^R}{2}. \label{eq:quantum-channel-parity} \end{equation} Double antiunitary conjugation is completely positive: if $K_i$ are Kraus operators for $\Phi$, then $\Theta_YK_i\Theta_X^{-1}$ are linear Kraus operators for $\Phi^R$, up to irrelevant scalar phases. Thus $\Phi^R$ and $\Phi_e$ are channels. The difference $\Phi_o$ is Hermiticity preserving and trace annihilating but generally not positive. \begin{proposition}[Quantum parity transport, composition and artifact bound] For $s=(\rho+J_X\rho)/2$, $d=(\rho-J_X\rho)/2$, the output parts are \begin{equation} s_{\rm out}=\Phi_es+\Phi_od,\qquad d_{\rm out}=\Phi_ed+\Phi_os. \label{eq:quantum-parity-transport} \end{equation} With $A(\rho)=\|d\|_1$ and $\epsilon(\Phi)=\sup_{\omega\ \mathrm{state}}\|\Phi_o\omega\|_1$, \begin{equation} A(\Phi\rho)\leq A(\rho)+\epsilon(\Phi),\qquad 0\leq\epsilon(\Phi)\leq1. \label{eq:quantum-artifact-bound} \end{equation} Also $\epsilon(\Phi)\leq\|\Phi-\Phi^R\|_\diamond/2$. Successive channels obey \begin{align} (\Psi\Phi)_e&=\Psi_e\Phi_e+\Psi_o\Phi_o,\notag\\ (\Psi\Phi)_o&=\Psi_e\Phi_o+\Psi_o\Phi_e, \label{eq:quantum-parity-composition} \end{align} and $\epsilon(\Psi\Phi)\leq\epsilon(\Psi)+\epsilon(\Phi)$. No spurious arrow is created from any even input if and only if $\Phi_o S_X=0$, where $S_X=(\mathrm{id}+J_X)/2$. \end{proposition} \begin{proof} Use $J_Xs=s$, $J_Xd=-d$ and $J_Y\Phi=\Phi^RJ_X$, and expand the output sum and difference. The triangle inequality and trace-norm contraction of $\Phi_e$ give~\eqref{eq:quantum-artifact-bound}; $s$ is a state. A difference of two states has trace norm at most two, which proves the range of $\epsilon$. The diamond-norm bound follows from its optimization over a larger input class. Since $(\Psi\Phi)^R=\Psi^R\Phi^R$, expansion proves both composition formulas. For the error budget write \[ \Psi\Phi-\Psi^R\Phi^R =\Psi(\Phi-\Phi^R)+(\Psi-\Psi^R)\Phi^R. \] Apply it to a state, use contraction on the first Hermitian difference and the definition of $\epsilon$ on the second, and divide by two. For an even input, $d_{\rm out}=\Phi_os$. Even density matrices span the even Hermitian subspace: add a sufficiently large multiple of $I$ to any even Hermitian matrix and normalize. Consequently vanishing on every even state is equivalent to $\Phi_oS_X=0$. \end{proof} Full covariance $\Phi=\Phi^R$ is sufficient but not necessary for the last property. For qubit complex conjugation $J$, measure $Y$ and prepare the corresponding $X$ eigenstate: \[ \Phi(\rho)=\frac{I+\operatorname{Tr}(\rho Y)X}{2}. \] Every even input maps to $I/2$, yet $\Phi\ne\Phi^R$. Conversely, a replacement apparatus preparing $(I+bY)/2$ from every input, $0