{ "id": "cps31f5bc772a", "source_id": "ap-v21", "cid": "cps31f5bc772a", "template_id": "cp_states", "question": "input/video.tif is a simulated fluorescence single-particle-tracking movie: 200 frames of 128 x 128 pixels (8-bit multipage TIFF, frames numbered 0-199 in file order). input/video.mp4 is the same movie upscaled 4x for viewing only, and input/frame0.png is frame 0. Positions are (x, y) in pixels of video.tif: x is the column and y the row, measured from the centre of the top-left pixel, with y increasing downward. Many particles move in the field of view and can pass close to each other. The target particle P is the spot centred at (x, y) = (11.7, 74.9) in frame 0; P stays inside the field of view for all 200 frames. Each particle's motion is piecewise: within one segment it follows a single diffusion law MSD(tau) = 4 K tau^alpha (2D, tau in frames, K in px^2/frame^alpha), and at a changepoint it switches to a different law. Label each segment by M10 = 4 K 10^alpha, the mean squared displacement of the motion itself over a 10-frame lag (localization noise excluded): \"immobile\" if M10 < 0.7 px^2, \"slow\" if 0.7 <= M10 < 12 px^2, \"fast\" if M10 >= 12 px^2. For the target particles in this question, consecutive segments always have different labels and every segment lasts at least 5 frames (a pause or burst shorter than 5 frames is not a separate segment); a particle may also have no changepoint at all. A changepoint is the index of the first frame of the new segment. A reported changepoint is correct if it lies within 5 frames of a true changepoint (one-to-one matching); missing or extra changepoints count as errors. Track P through the whole movie and report all of its changepoints in increasing order and the label of every segment in time order (the list of labels has one more entry than the list of changepoints). Answer with a JSON object {\"changepoints\": [frame, ...], \"states\": [label, ...]} where each label is \"immobile\", \"slow\" or \"fast\".", "answer_format": "object", "answer": { "changepoints": [ 5, 131, 136 ], "states": [ "fast", "slow", "fast", "slow" ] }, "unit": "frame index / label", "tolerance": { "changepoints": { "type": "f1_radius", "value": 5 }, "states": { "type": "exact" } }, "gt_source": "Zenodo 10.5281/zenodo.14281479 andi2_benchmark_dataset.zip: track_1/exp_7/traj_labs_fov_28.txt rows traj_idx=24 (segment K, alpha, state, changepoints; label = M10 class of 4 K 10^alpha); trajs_fov_28.csv frame 0 of the same traj_idx -> seed position (x = y_traj + dc, y = x_traj + dr, offset from the VIP label page of videos_fov_28.tiff). Labeling convention: each segment is classified by M10 = 4K·10^α into immobile (<0.7 px²) / slow (<12) / fast; changepoints = the segment start frames in the authors' traj_labs (the authors' labels have already been smoothed with a 5-frame window via andi_datasets label_filter, minimum segment length 3 frames).", "gt_type": "Fixed ground truth (simulation parameters)", "provenance": [ "https://zenodo.org/api/records/14281479/files/andi2_benchmark_dataset.zip/content (track_1/exp_7/videos_fov_28.tiff, track_1/exp_7/trajs_fov_28.csv, track_1/exp_7/traj_labs_fov_28.txt, track_1/exp_7/vip_idx_fov_28.txt)" ], "prep_notes": "Removed the VIP label image on TIFF page 1; the 200 frames are saved separately as input/video.tif; the mp4 is 4x nearest-neighbor upscaled, 20 fps, metadata stripped; frame0.png is frame 0 at native resolution. The seed coordinate is the target's position at frame 0 in trajs_fov (including 0.12 px localization noise) converted to pixel coordinates; the pixel offset is obtained by rounding the median difference between the VIP label image centroids and the trajectory first points, and it has been verified that the seed falls within that VIP's label spot.", "expected_approach": "Localize spots frame by frame and link the trajectory starting from the seed (preserving identity at crossings via motion continuity), then segment the trajectory using sliding-window MSD/displacement distributions, HMM or changepoint detection, assign labels by each segment's M10, and merge pauses shorter than 5 frames.", "shortcut_risk": "Answering no changepoints for all: in cp_states 125/312 (40%) of items have no changepoints; answering [] for all plus guessing the single label correctly earns this portion; no-changepoint items are dominated by the fast/slow/immobile distribution; in cp_multi each group has at least two targets with changepoints. Motion cannot be determined from the first frame alone.", "first_only_note": "Only the first image/frame is available in this run.", "why_multi_look": "One must first locate the target spot by coordinates in frame 0, then track it frame by frame through 200 frames (other particles come close during this time, so identity must be maintained via motion continuity), determine from the local MSD of the whole trajectory whether each segment is immobile/slow/fast, and compare adjacent time periods back and forth to pin down each changepoint frame; from the first frame alone one cannot even tell whether the particle will move.", "specialist_check": "Off-the-shelf pipelines are single-particle tracking such as TrackPy/u-track plus AnDi 2 entrant changepoint/segmentation methods (e.g. STEP, U-net/LSTM segmentation networks, HMM, sliding-window MSD); these methods track first and then segment, and identity errors at crossings, short pauses and subdiffusive slow states all produce over-reporting or misses, so it cannot be guaranteed that all changepoints and labels are correct; a dedicated model must be actually run to rule this out in one step.", "n_materials": 200, "strata": { "model": "multi_state_2", "n_cp": 3, "labels": "fast-slow-fast-slow", "min_seg": 5, "min_cp_gain": 13.1, "dmin_other_px": 3.5, "n_brief_close": 0, "n_near5": 1, "pseudo_pauses": 6, "hard_flags": [ "multi_cp", "pseudo_pause", "slow_state", "short_segment", "weak_contrast" ], "hard": true }, "audit": { "scores": [ 0.5, 0.25, 0.286 ], "preds": [ { "changepoints": [ 5, 133, 138 ], "states": [ "fast", "immobile", "fast", "immobile" ] }, { "changepoints": [ 5 ], "states": [ "fast", "slow" ] }, { "changepoints": [ 5, 89, 113, 134 ], "states": [ "fast", "immobile", "slow", "immobile", "slow" ] } ], "correct_flags": [ false, false, false ], "consistent_wrong": false, "best_err_tol_units": 0.4, "shortcuts": { "baseline": null, "text_guess": null, "specialist": 0.0, "one_look": null, "blind": null }, "category": "d", "evidence": "Ground-truth self-assessment 1.0; independent recomputation: without reading traj_labs, using the per-frame D/α columns in trajs_fov to find parameter-change frames, frame-by-frame agreement with the ground truth (True); the authors' 5-frame label smoothing did not alter changepoints on these items (csv parameter-change frames = ground truth). Segments and M10: P: 0–4 fast(M10=74.44, measured on true trajectory nan), 5–130 slow(M10=1.55, measured on true trajectory 1.63), 131–135 fast(M10=74.44, measured on true trajectory nan), 136–199 slow(M10=1.55, measured on true trajectory 1.57). Visibility: P: the target's dimmest frame along the true trajectory is still 62.0 above background (background noise about 4–8 gray levels), within the field of view throughout. Label decidability simulation (perfect observation) maximum misclassification rate 0.28, occurring only on fast short pulses of ≤10 frames (labels on both sides are fixed, fast and immobile step sizes differ by an order of magnitude, does not affect determination). P: agent over-reported/misplaced changepoints [89, 113], with other particles within 5 px nearby [(89, [(2, 4.08)]), (113, [(2, 4.2)])]. See plot true_track_msd.png: the true trajectory's 10-frame displacement jumps clearly at the ground-truth changepoints, while most of the agent's changepoints fall at positions with no parameter change and no change in any other particle. Dedicated model (TrackPy+U-AnD-ME) 0.0, did not pass 0.75.", "trace_labels": [ [ "looked", "specialist_tool" ], [ "looked", "specialist_tool" ], [ "looked", "specialist_tool" ] ], "why_wrong": "The agent uses greedy brightest-pixel tracking without revisiting the video, and loses the target or switches to another particle when passing within 2–5 px of other particles, so changepoints are misplaced or over-reported; finding changepoints with a 10-frame window also delays the onset by 5–8 frames, exceeding the 5-frame tolerance.", "action": "Keep in the evaluation set (only this item retained for this field of view); add blind answers and a second model family." } }