/*---------------------------------------------------------------------------*\ ========= | \\ / F ield | OpenFOAM: The Open Source CFD Toolbox \\ / O peration | Website: https://openfoam.org \\ / A nd | Copyright (C) 2011-2022 OpenFOAM Foundation \\/ M anipulation | ------------------------------------------------------------------------------- License This file is part of OpenFOAM. OpenFOAM is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version. OpenFOAM is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with OpenFOAM. If not, see . Global setDeltaT Description Reset the timestep to maintain a constant maximum courant Number. Reduction of time-step is immediate, but increase is damped to avoid unstable oscillations. \*---------------------------------------------------------------------------*/ if (adjustTimeStep) { scalar deltaT = 1.2*runTime.deltaTValue(); if (CoNum > small) { deltaT = min(deltaT, maxCo/CoNum*runTime.deltaTValue()); } deltaT = min(min(deltaT, fvModels.maxDeltaT()), maxDeltaT); runTime.setDeltaT(deltaT); Info<< "deltaT = " << runTime.deltaTValue() << endl; } // ************************************************************************* //