--- license: cc-by-nc-4.0 language: - en pretty_name: "Checking a Stereo Calibration on Ordinary Footage (Field Note #04)" tags: - robotics - physical-ai - egocentric - stereo-vision - camera-calibration - fisheye - epipolar-geometry - kalibr - opencv - evaluation task_categories: - other size_categories: - n<1K configs: - config_name: default data_files: - split: train path: data/evaluation_summary.csv --- # Checking a Stereo Calibration on Ordinary Footage **Origin Data Lab · Technical Field Note #04 · 23 October 2026** [![Field Note](https://img.shields.io/badge/Field_Note-%2304-0B1220?style=for-the-badge)](https://origindatalab.io/technical-field-notes/stereo-calibration-check.html) ![Python](https://img.shields.io/badge/Python-3.9%2B-3776AB?style=for-the-badge) ![License](https://img.shields.io/badge/Code-MIT-16A34A?style=for-the-badge) > **Short answer.** You can check whether a stereo calibration fits a device and capture mode using ordinary footage, without a target. On a 120 s, 1600×1200 head-mounted stereo recording, a Kalibr calibration from the same capture mode gave a **median angular epipolar error of 0.41 px** on 19,386 unfiltered matches; a calibration of the same camera family from a different (16:9) mode gave **1.83 px**. Two common checks can mislead on wide-angle lenses (see below). **Code and issues:** [GitHub — origin-data-lab/stereo-calibration-validation](https://github.com/origin-data-lab/stereo-calibration-validation) **Full article:** [Technical Field Note #04 — Checking a Stereo Calibration on Ordinary Footage](https://origindatalab.io/technical-field-notes/stereo-calibration-check.html) --- ## Key results | Result | Value | |---|---:| | Median angular epipolar error, mode-matched calibration, no adjustment | **0.41 px** (19,386 matches, 29 frame pairs) | | Same matches, calibration from a different capture mode | **1.83 px** | | Stereo-rotation correction requested by the data | **< 0.02°** per axis | | Deliberate 0.1° pitch error | median rises to **0.76 px** | | Rectified vertical residual, 0–20° vs 75–90° field angle | **0.50 px → 4.05 px** (angular metric stays **0.46 px**) | | `cv2.fisheye.undistortPoints` (OpenCV 5.0, defaults) | exact to ~**74°**; **4.5°** wrong at 80°, **8.0°** at 85° for this lens | All values are from the evaluated recording and configuration; they are not universal guarantees. ## Two traps on wide-angle stereo **1. Rectified vertical residuals inflate toward the image edge.** Projecting wide-angle rays onto a flat rectified image stretches the periphery (roughly 1/cos² of the angle), so a correct calibration looks wrong at the edges. Use an angular metric, or restrict rectified checks to the central field of view. **2. OpenCV's default fisheye un-projection clamps the distorted angle at π/2.** With a positive k₁, θd reaches π/2 before the true ray angle reaches 90°, and every point beyond returns at the wrong angle. Run `tools/fisheye_roundtrip_check.py` with your own coefficients to see where this happens for your lens. ## Tools ```bash pip install opencv-python numpy scipy pyyaml # 1. Validate a Kalibr pinhole-equidistant stereo calibration on ordinary stereo footage python tools/validate_stereo_calib.py --left left.mp4 --right right.mp4 \ --camchain camchain.yaml --scale 2 --out result.json # --scale = video resolution / calibration resolution # 2. Find where OpenCV's fisheye un-projection breaks for your coefficients python tools/fisheye_roundtrip_check.py --camchain camchain.yaml --cam cam0 --scale 2 python tools/fisheye_roundtrip_check.py --k 0.12 0 0 0 --f 480 --cx 800 --cy 600 ``` ## Repository contents | Path | Contents | |---|---| | `tools/validate_stereo_calib.py` | Target-free stereo calibration check (angular epipolar error, field-angle breakdown, held-out rotation fit) | | `tools/fisheye_roundtrip_check.py` | OpenCV fisheye round-trip test | | `results/` | Measured results behind the article (JSON) | | `data/evaluation_summary.csv` | Key numbers as a table (shown in the Dataset Viewer) | | `figures/` | Figures used in the article | The device calibration parameters and the source recording are not published in this repository. ## What this check does not verify - **Baseline length / metric scale** — absent from the epipolar constraint. - **Metric depth accuracy** — requires targets at measured distances. - **Camera–IMU calibration** — time shift and extrinsics need a separate test. ## Cite ```bibtex @misc{origindatalab2026fieldnote04, author = {{Origin Data Lab}}, title = {Checking a Stereo Calibration on Ordinary Footage}, howpublished = {Technical Field Note \#04}, year = {2026}, url = {https://origindatalab.io/technical-field-notes/stereo-calibration-check.html} } ``` Or: ``` Origin Data Lab (2026). Checking a Stereo Calibration on Ordinary Footage. Technical Field Note #04. https://origindatalab.io/technical-field-notes/stereo-calibration-check.html ``` ## License - Code in `tools/`: MIT - Text, results and figures: [CC BY-NC 4.0](https://creativecommons.org/licenses/by-nc/4.0/) — free to share and adapt for non-commercial use with attribution to Origin Data Lab. ## Related - [All Technical Field Notes](https://origindatalab.io/technical-field-notes/) - [한국어 — 스테레오 캘리브레이션 검증 (Field Note #04)](https://origindatalab.io/ko/technical-field-notes/stereo-calibration-check.html) - [#03 Stereo + IMU Egocentric Capture](https://origindatalab.io/technical-field-notes/stereo-imu-egocentric-sample.html) · [dataset card](https://huggingface.co/datasets/origindatalab/stereo-imu-egocentric-evaluation) --- **Origin Data Lab** — real-world data production for Physical AI and robotics · [origindatalab.io](https://origindatalab.io) · [contact@origindatalab.io](mailto:contact@origindatalab.io) Need per-device, per-capture-mode stereo calibration validated on your own footage? [Contact us](https://origindatalab.io/contact.html).