# Technical Boundaries The measurements in this public evidence package describe one tested device and software configuration during a continuous real-world field recording. ## This Evaluation Does Not Claim - Hardware frame-level video-IMU synchronization - Sub-frame synchronization - Camera-exposure-level timestamp synchronization - A guaranteed 410 Hz hardware specification - Guaranteed continuous 100 Hz application-level delivery - 12 independent experimental sessions - A determined cause for the observed timing gaps - Universal performance across every device, environment, capture architecture, or future project ## Observed Limitations One of 12 evaluated segments showed a maximum video inter-frame gap above 100 ms. The maximum observed video gap was **499.80 ms**. Application-level accelerometer and gyroscope streams showed gaps above 100 ms in all 12 evaluated segments. Maximum observed gaps were: - Accelerometer: **589.34 ms** - Gyroscope: **599.08 ms** Native IMU streams did not show gaps of comparable magnitude in this evaluation. The cause of the application-level timing gaps has not been established. No attribution is made to buffering, batching, Android scheduling, downsampling, resampling, or another specific mechanism. ## Interpretation The evidence supports measured native sensor timing characteristics, timestamp integrity, and capture-session temporal bracket coverage for the evaluated configuration. It does not support stronger synchronization or universal hardware-performance claims.