[ { "id": "gold_0507_000004", "source_id": "034560ce0e55", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nIMU-Based Wearable Motion Data Collection for Activity Recognition.\n\nObjective:\n\nTo collect synchronized motion data using a custom wearable system with two inertial measurement units for activity recognition and orientation-estimation validation. The protocol targets classification of six activities, including walking, running, sitting, standing, stair ascent, and stair descent, and evaluates both activity-recognition performance and sensor-fusion accuracy against an optical motion capture reference.\n\nEquipment:\n\nThe wearable system comprises two IMUs: a 6-axis Bosch BNO055 with a ±16g accelerometer and ±2000 dps gyroscope, and a 9-axis InvenSense ICM-20948 with a ±16g accelerometer, ±2000 dps gyroscope, and ±4900 µT magnetometer.\n\nA Bluetooth-connected Nordic nRF52840 microcontroller is used for synchronous sampling and streaming to a host computer for real-time logging. All data processing is performed in MATLAB R2023a. A gold-standard optical motion capture system, Vicon, is used for orientation-estimation validation.\n\nSensor Placement & Configuration:\n\nThe sensors are placed on the dominant wrist and lower back of each participant using adjustable straps. Data are sampled synchronously at 200 Hz through the Bluetooth-connected microcontroller. The accelerometer and gyroscope (10Hz/50Hz) are set via internal digital filters to prevent aliasing,\n\nData Acquisition Procedure:\n\nMotion data are collected from each participant using the custom wearable system. The Bosch BNO055 and InvenSense ICM-20948 IMUs are worn on the dominant wrist and lower back, and the data streams are sampled synchronously at 200 Hz.\n\nThe data are streamed to a host computer for real-time logging. The dataset includes six activities: walking, running, sitting, standing, stair ascent, and stair descent.\n\nSignal Processing & Validation:\n\nRaw sensor data undergo a signal processing pipeline. A 4th-order Butterworth low-pass filter with a 20 Hz cutoff is applied to the accelerometer signals to attenuate high-frequency noise. Gyroscope data are similarly filtered at 25 Hz.\n\nFor activity recognition, a 1-second sliding window with 50% overlap is used to segment the data. From each window, 42 time- and frequency-domain features are extracted, including mean, variance, zero-crossing rate, and power in the 0–5 Hz, 5–10 Hz, and 10–20 Hz bands.\n\nA Random Forest classifier with 100 trees is trained on a 70/30 subject-wise split of the data to classify walking, running, sitting, standing, stair ascent, and stair descent. Validation is performed on a separate test set of 10 participants. Classification performance is evaluated using overall accuracy, F1-score, and confusion matrices.\n\nThe system is expected to achieve greater than 95% accuracy for gross motor activities, including walking and running, and greater than 85% accuracy for transitional and static activities. Sensor fusion accuracy is assessed by comparing orientation estimates from the 9-axis IMU, using an extended Kalman filter, against the Vicon optical motion capture system, with a target orientation error of less than 3 degrees RMS.\n\nSafety & Feasibility:\n\nThe sensors are attached to the dominant wrist and lower back using adjustable straps. Data are sampled synchronously at 200 Hz and streamed via Bluetooth to a host computer for real-time logging. Validation includes a separate test set of 10 participants and comparison against a Vicon optical motion capture system.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The accelerometer bandwidth is set to 10 Hz, but the signal processing requires frequencies up to 20 Hz (low-pass filter cutoff at 20 Hz and features in the 10-20 Hz band). This bandwidth mismatch means the sensor cannot capture the necessary high-frequency components, rendering the data acquisition and subsequent analysis physically invalid. Fix: Increase the accelerometer bandwidth to at least 20 Hz to match the signal frequency content.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000012", "source_id": "735250a8b05e", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nConcurrent EEG Acquisition for Motor Imagery Classification and P300 Detection.\n\nObjective:\n\nTo acquire synchronized EEG data using wet gel EEG, dry EEG, and ear-EEG systems for motor imagery classification and P300 detection, retaining alpha, beta, and mu rhythms for motor imagery analysis and extracting P300 spatiotemporal features for a 2-class speller task.\n\nEquipment:\n\nEEG data will be acquired using three concurrent systems. The wet gel EEG system is a 64-channel BioSemi ActiveTwo system with wet gel electrodes, 24-bit ADC resolution, 2048 Hz sampling rate, and 0.16–100 Hz bandwidth.\n\nThe dry EEG system is a 16-channel g.tec g.SCARABEO dry electrode system with 16-bit ADC resolution, 512 Hz sampling rate, and 2–45 Hz bandwidth.\n\nThe ear-EEG system is a 6-channel Natus EEG ear-EEG system with 16-bit ADC resolution, 256 Hz sampling rate, and 1–50 Hz bandwidth. All systems will be time-synchronized via TTL triggers.\n\nSensor Placement & Configuration:\n\nThe wet gel EEG system will provide 64-channel scalp EEG acquisition. The dry EEG system will provide 16-channel dry-electrode EEG acquisition. The ear-EEG system will provide 6-channel ear-EEG acquisition.\n\nFor motor imagery classification, Common Spatial Patterns will be computed from the central electrodes C3, Cz, and C4. For P300 detection, features will be extracted from the P300 spatiotemporal window of 300–500 ms at electrodes Pz, POz, and Oz.\n\nData Acquisition Procedure:\n\nA minimum of 10 participants will perform a 4-class motor imagery task and a 2-class P300 speller task. Session duration will be limited to 90 minutes to prevent fatigue.\n\nAll three EEG systems will acquire data concurrently and will be time-synchronized via TTL triggers. All raw data will be streamed in real time via Bluetooth LE at full resolution.\n\nSignal Processing & Validation:\n\nData will be bandpass filtered offline between 1–50 Hz to retain alpha rhythms at 8–13 Hz, beta rhythms at 13–30 Hz, and mu rhythms at 8–12 Hz. A 50 Hz notch filter will be applied to suppress line noise. Independent Component Analysis will be used to remove ocular and muscular artifacts.\n\nFor motor imagery classification, Common Spatial Patterns will be computed on the filtered signals from the central electrodes C3, Cz, and C4 for feature extraction. A shrinkage Linear Discriminant Analysis classifier will be trained and validated using a stratified 10-fold cross-validation scheme.\n\nFor P300 detection, a separate pipeline will apply a 0.5–20 Hz bandpass filter, epoch data from -200 to 800 ms relative to stimulus onset, baseline-correct using the pre-stimulus interval, and average responses per class. Features will be extracted from the P300 spatiotemporal window of 300–500 ms at electrodes Pz, POz, and Oz, and classified using a stepwise Linear Discriminant Analysis classifier.\n\nThe primary performance metric will be classification accuracy. Additional metrics, including Cohen’s Kappa coefficient and information transfer rate, will be calculated to evaluate BCI efficacy.\n\nSafety & Feasibility:\n\nSession duration will be limited to 90 minutes to prevent fatigue. The protocol uses time-synchronized concurrent EEG acquisition from wet gel EEG, dry EEG, and ear-EEG systems via TTL triggers. All raw data will be streamed in real time via Bluetooth LE at full resolution.", "three_class_category": "Signal & Sampling", "violated_constraint": "data_bandwidth", "violated_principle": "Communication bandwidth infeasibility", "why_invalid": "The required real-time raw data rate exceeds the practical sustained bandwidth of the communication link. Without compression, channel reduction, or local feature extraction, the data stream will suffer loss or excessive latency. In this sample, the problematic modification is: All systems will be time-synchronized via TTL triggers..", "minimal_fix": "Reduce the transmitted data rate through local feature extraction, compression, channel reduction, or a lower sampling rate, or use a link with sufficient sustained bandwidth.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000026", "source_id": "c7676440774e", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nSurface Electromyography Acquisition for Upper Arm Gesture Classification.\n\nObjective:\n\nTo acquire surface electromyography signals from eight targeted upper arm muscles using wet gel Ag/AgCl electrodes and a high-density dry electrode array, and to classify five target gestures and the rest state using extracted sEMG features.\n\nEquipment:\n\nWet gel Ag/AgCl electrodes, Kendall Medi-Trace 100, will be used to provide high-fidelity reference signals. A high-density dry electrode array, Delsys Trigno HD sensor, will be used to capture spatial activation patterns with 16 channels.\n\nSignals will be recorded using a Delsys Trigno Avanti wireless system at a sampling rate of 2000 Hz with 24-bit ADC resolution. The system’s built-in bandpass filter will be set to 20–500 Hz to capture the relevant sEMG spectrum, with a 60 Hz notch filter to reject power-line noise.\n\nSensor Placement & Configuration:\n\nsEMG signals will be acquired from eight targeted upper arm muscles, including biceps brachii, triceps brachii, brachialis, and brachioradialis. Electrodes will be placed following SENIAM guidelines.\n\nThe wet gel electrodes will provide high-fidelity reference signals, while the 16-channel dry array will capture spatial activation patterns. The high-density array will use an inter-electrode distance of 10 mm. Skin will be prepared with gentle abrasion and alcohol cleaning to reduce impedance.\n\nData Acquisition Procedure:\n\nParticipants will perform five target gestures, including fist, finger spread, wrist flexion, wrist extension, and pinch, as well as the rest state. For each gesture and the rest state, participants will perform 20 repetitions of 5-second contractions.\n\nEach trial will include a 5-second contraction period followed by a 3-second rest period. sEMG data will be recorded across the wet gel Ag/AgCl electrodes and the 16-channel dry array using the Delsys Trigno Avanti wireless system.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will begin with a 2nd-order Butterworth high-pass filter at 30 Hz to remove motion artifacts. Root-mean-square and mean absolute value features will be extracted from 200 ms windows with 100 ms overlap across all 24 channels.\n\nA Linear Discriminant Analysis classifier will be trained using a 10-fold cross-validation protocol. Performance will be evaluated using overall accuracy, confusion matrix, and F1-score per gesture class.\n\nExpected performance for a robust system is greater than 95% accuracy across all gestures with a latency of less than 300 ms. Signal quality will be monitored by ensuring electrode-skin impedance below 5 kΩ for wet electrodes and signal-to-noise ratio greater than 20 dB for dry electrodes.\n\nSafety & Feasibility:\n\nSkin will be prepared with gentle abrasion and alcohol cleaning to reduce impedance. Signal quality will be monitored by ensuring electrode-skin impedance below 5 kΩ for wet electrodes and signal-to-noise ratio greater than 20 dB for dry electrodes. Each 5-second contraction trial will be followed by a 3-second rest period.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement sEMG signals from upper arm muscles do not generate the target physiological signals for hand gestures; the classifier would fail to recognize gestures, resulting in accuracy near chance level (e.g., <20% for five gestures, far below the expected >95%). Fix: Place electrodes on forearm muscles that control hand and wrist movements, such as flexor digitorum superficialis and extensor digitorum.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000033", "source_id": "fae92b42d874", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "valid", "protocol": "Protocol: FMCW Millimeter-Wave Radar Vital Sign Monitoring\nObjective: To monitor vital signs using FMCW millimeter-wave radar.\nEquipment: Texas Instruments IWR1443BOOST or equivalent 77-81 GHz FMCW radar module. The radar is configured with single transmit and three receive antennas (1Tx/3Rx) for angle estimation. Chirp parameters include start frequency of 77 GHz, bandwidth of 4 GHz, chirp time of 5 ms, number of ADC samples per chirp of 256, ADC sampling rate of 5 Msps, and frame rate of 200 Hz (200 chirps per second).\nSensor Placement & Configuration: The radar sensor should be placed facing a seated human subject at a distance of 1.0 ± 0.1 meter. The subject must face the radar antenna, and the radar beam (approximately 60° azimuth) must be aligned to the subject's thorax.\nData Acquisition Procedure: Acquire raw I/Q data for a minimum duration of 30 seconds per measurement epoch to ensure stable spectral estimation.\nSignal Processing & Validation: Perform a 256-point Fast Fourier Transform (FFT) on the ADC samples of each chirp to generate a range profile. Identify the range bin corresponding to the subject's chest wall based on the strongest static or slow-moving reflection. For the selected range bin, extract the phase signal φ(t) from the complex I/Q data across successive chirps. This phase is proportional to sub-millimeter chest wall displacement. Apply a 4th-order Butterworth bandpass filter to φ(t) with a respiration band of 0.1 Hz to 0.5 Hz (6 to 30 breaths per minute) and a heart rate band of 0.8 Hz to 2.0 Hz (48 to 120 beats per minute). Compute the power spectral density using Welch's method for each filtered signal. The peak frequency in the respective band corresponds to the respiration rate and heart rate. Under controlled, low-clutter conditions, this protocol is expected to achieve heart rate accuracy of ±2 beats per minute compared to a reference pulse oximeter and respiration rate", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000042", "source_id": "50172d3ff07d", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture and Activity Recognition\n\nObjective: To establish a validated method for capturing human motion and recognizing daily activities using inertial measurement units (IMUs).\n\nEquipment: 3x 9-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps, magnetometer ±4900 µT) and 3x 6-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps). All IMUs synchronized at 250 Hz sampling rate (Nyquist frequency >100 Hz for motion). Data logger is a central unit with microSD storage, Bluetooth LE for real-time monitoring, and GPIO for external sync.\n\nSensor Placement & Configuration: 9-axis IMUs are placed on the sternum (posterior), right wrist (dorsal), and left ankle (medial) for global orientation and complex motion. 6-axis IMUs are placed on the right thigh (anterior, mid-shank), left forearm (posterior), and head (occipital) for segmental kinematics. Mounting uses rigid, skin-tight straps with medical adhesive to minimize soft-tissue artifact.\n\nData Acquisition Procedure: Participant preparation includes 10 minutes of quiet standing for sensor baseline calibration, with demographics and anthropometrics recorded. Motion tasks are performed with 5 trials each: static tasks (sitting, standing), dynamic tasks (walking at self-selected speed, stair ascent/descent, sit-to-stand transitions), and activity recognition tasks (picking up an object, carrying a load (2kg), opening a door). Ground truth is obtained via synchronized optical motion capture (Vicon, 100 Hz) with retroreflective markers on sensor locations and major joints.\n\nSignal Processing & Validation: Pre-processing involves a low-pass Butterworth filter (cutoff 20 Hz) for accelerometer data; gyroscope data is left unfiltered for high-frequency analysis. Orientation estimation uses an Extended Kalman Filter (EKF) fusing accelerometer, gyroscope, and magnetometer (where available) data. Feature extraction includes time-domain (mean, variance, zero-crossings) and frequency-domain (power spectral density) features from 2-second sliding windows. Validation compares IMU-derived joint angles against optical motion capture using Root Mean Square Error (RMSE) and Pearson correlation (target r > 0.95), and activity classification accuracy is evaluated against manual video labeling.\n\nSafety & Feasibility: The protocol uses non-invasive IMUs mounted with medical adhesive to minimize soft-tissue artifact and ensure participant comfort. The experimental protocol is approved by an institutional ethics board, ensuring ethical compliance. Tasks are designed to be safe and feasible for participants.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000057", "source_id": "914dd67962a0", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG-Based Motor Imagery and P300 Classification Using Wet Gel, Dry, and Ear-EEG Systems.\n\nObjective:\n\nTo acquire simultaneous EEG data from wet gel, dry electrode, and ear-EEG systems for classification of left hand, right hand, and foot motor imagery, and for P300 detection in a separate target/non-target task.\n\nEquipment:\n\nThe study will recruit 20 healthy, right-handed participants aged 18–35 after obtaining written informed consent, in accordance with the Declaration of Helsinki.\n\nEEG data will be acquired simultaneously from three systems. The wet gel system is a 64-channel g.tec g.USBamp system with g.LADYbird electrodes, sampled at 256 Hz. The dry electrode system is a 32-channel Cognionics Quick-20 system, sampled at 500 Hz. The ear-EEG system is a 16-channel Nerospec earEEG system, sampled at 250 Hz. All systems use 24-bit ADCs.\n\nSensor Placement & Configuration:\n\nWet and dry caps will be positioned according to the 10–20 system, focusing on central and parietal areas including C3, Cz, C4, and Pz. The ear-EEG electrodes will be placed in a custom in-ear mold. The signal quality of different preamplifiers and those without preamplifiers are compared.\n\nData Acquisition Procedure:\n\nThe experimental paradigm will present visual cues for left hand, right hand, and foot motor imagery. A total of 100 trials per class will be collected.\n\nA separate target/non-target task will be used for P300 detection. EEG data will be recorded simultaneously from the wet gel, dry electrode, and ear-EEG systems.\n\nSignal Processing & Validation:\n\nRaw signals will be bandpass filtered from 1–45 Hz and notch-filtered at 50 Hz. For wet and dry EEG, artifacts will be rejected using Independent Component Analysis. For ear-EEG, a wavelet-based thresholding method will be applied.\n\nFeatures will be extracted using Common Spatial Patterns over the 8–30 Hz band, encompassing mu and beta rhythms, followed by log-variance feature extraction. For P300 detection, features will be extracted from a 0–800 ms post-stimulus window.\n\nClassification will be performed using a Linear Discriminant Analysis classifier with 10-fold cross-validation. Validation will assess classification accuracy, Cohen’s Kappa coefficient, and Information Transfer Rate.\n\nExpected performance is greater than 85% accuracy for wet gel electrodes, greater than 75% for dry electrodes, and greater than 65% for ear-EEG in the 3-class motor imagery task. P300 detection accuracy is expected to exceed 90% for all systems. Performance differences between sensor types will be statistically compared using repeated-measures ANOVA.\n\nSafety & Feasibility:\n\nParticipants will be healthy, right-handed adults aged 18–35. Written informed consent will be obtained in accordance with the Declaration of Helsinki. The protocol uses simultaneous recording from wet gel, dry electrode, and ear-EEG systems, with no preamplifier or electromagnetic shielding.", "three_class_category": "Signal & Sampling", "violated_constraint": "snr_floor", "violated_principle": "Signal-to-noise floor violation", "why_invalid": "The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: The study will recruit 20 healthy, right-handed participants (age 18-35) after obtaining written informed consent, in accordance with the Declaration of Helsinki..", "minimal_fix": "Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000058", "source_id": "a96a98b00d23", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nIMU-Based Motion Capture and Activity Recognition Using 6-Axis and 9-Axis IMUs.\n\nObjective:\n\nTo acquire motion data using a 6-axis MEMS IMU and a 9-axis IMU for orientation estimation, joint kinematics validation, and activity recognition across a dataset of 10 activities collected from 20 participants.\n\nEquipment:\n\nData will be acquired using a Bosch BMI270 6-axis MEMS IMU and a Bosch BNO055 9-axis IMU. Both sensors will be configured with an accelerometer range of ±16g and a gyroscope range of ±2000 dps.\n\nA custom National Instruments NI-9234 24-bit data acquisition system will be used to sample the data at 500 Hz. Raw data streams will be transmitted via Bluetooth Low Energy to a host PC for offline processing. A Qualisys optical motion capture system operating at 120 Hz will be used as the gold-standard reference for joint angle validation. All data processing will be implemented in Python 3.8 using the SciPy and scikit-learn libraries.\n\nSensor Placement & Configuration:\n\nSensors will be affixed to the dominant wrist and sternum of participants using medical-grade adhesive patches. The acquisition setup will sample both IMU systems at the predefined frequency to capture the full bandwidth of the target signals, including accelerometer DC–200 Hz and gyroscope DC–2000 Hz.\n\nSensor-specific bias calibration will be performed using a static 6-position tumble test for accelerometers and a rotational rate table for gyroscopes.\n\nData Acquisition Procedure:\n\nData will be collected from 20 participants performing a dataset of 10 activities, including walking, sitting, and stair ascent. The Bosch BMI270 and Bosch BNO055 sensors will record motion data from the dominant wrist and sternum during the activity protocol.\n\nRaw data streams will be sampled using the custom 24-bit National Instruments NI-9234 data acquisition system and transmitted via Bluetooth Low Energy to a host PC for offline processing. IMU-derived joint angles will be compared against the Qualisys optical motion capture system sampled at 120 Hz.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will begin with application of a 4th-order Butterworth low-pass filter with a 50 Hz cutoff to the accelerometer data to attenuate high-frequency noise while preserving motion harmonics. Sensor-specific bias calibration will be performed using a static 6-position tumble test for accelerometers and a rotational rate table for gyroscopes.\n\nA complementary filter with α = 0.98 will be computed to fuse accelerometer and gyroscope data for orientation estimation. For activity recognition, a 2-second sliding window with 50% overlap will be applied to the processed signals. Time-domain features, including mean, variance, and zero-crossing rate, and frequency-domain features, including spectral energy and dominant frequency, will be extracted.\n\nA Random Forest classifier with 100 trees and maximum depth of 15 will be trained on the 10-activity dataset. Seventy percent of the data will be used for training and 30% for validation. Validation will compare IMU-derived joint angles against the Qualisys optical motion capture system. Expected performance metrics include root-mean-square error of less than 5 degrees for joint kinematics and classification accuracy and F1-score exceeding 92% for the activity recognition task.\n\nSafety & Feasibility:\n\nSensors will be attached to the dominant wrist and sternum using medical-grade adhesive patches. The protocol uses wearable IMU sensors, Bluetooth Low Energy transmission to a host PC, and offline processing in Python 3.8. Validation will be performed against a Qualisys optical motion capture system operating at 120 Hz.", "three_class_category": "Signal & Sampling", "violated_constraint": "data_bandwidth", "violated_principle": "Communication bandwidth infeasibility", "why_invalid": "The required real-time raw data rate exceeds the practical sustained bandwidth of the communication link. Without compression, channel reduction, or local feature extraction, the data stream will suffer loss or excessive latency. In this sample, the problematic modification is: Data were acquired using a 6-axis MEMS IMU (Bosch BMI270) and a 9-axis IMU (Bosch BNO055), both configured with an accelerometer range of ±16g and a gyroscope range of ±2000 dps..", "minimal_fix": "Reduce the transmitted data rate through local feature extraction, compression, channel reduction, or a lower sampling rate, or use a link with sufficient sustained bandwidth.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000078", "source_id": "f4d56b051dd8", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG-Based Motor Imagery and P300 Detection Using a Hybrid Wet Gel, Dry, and Ear-EEG Montage.\n\nObjective:\n\nTo acquire EEG data using a hybrid electrode montage for cue-based motor imagery classification involving left hand, right hand, and feet movements, and to elicit P300 responses using a separate auditory oddball paradigm.\n\nEquipment:\n\nEEG data will be acquired using a g.tec g.USBamp amplifier system with 24-bit ADC resolution and a sampling rate of 512 Hz.\n\nThe hybrid electrode montage will include 16 active wet gel electrodes, g.LADYbird, 8 dry electrodes, g.SCARABEO, and 4 ear-EEG electrodes, g.EARclip. The system bandwidth will be set to 0.1–100 Hz with a 50 Hz notch filter.\n\nSignal processing will be implemented in MATLAB.\n\nSensor Placement & Configuration:\n\nThe 16 active wet gel electrodes will be positioned according to the international 10–20 system over the sensorimotor cortex, including C3, Cz, C4, and surrounding positions.\n\nThe 8 dry electrodes will be placed over frontal and upper trapezius muscle areas. The 4 ear-EEG electrodes will be used for reference and additional signal capture.\n\nData Acquisition Procedure:\n\nParticipants will perform a cue-based motor imagery task involving left hand, right hand, and feet movements. The experimental paradigm will consist of 5 runs of 40 trials each.\n\nDuring each trial, visual cues will be presented for 4 seconds, followed by a 2-second rest interval. The P300 response will be elicited using a separate oddball paradigm with auditory stimuli.\n\nSignal Processing & Validation:\n\nRaw data will be bandpass filtered from 1–40 Hz using a 4th-order Butterworth filter. Independent Component Analysis will be used to remove ocular and muscular artifacts.\n\nFor motor imagery classification, features will be extracted using Common Spatial Patterns applied to the mu band of 8–12 Hz and beta band of 13–30 Hz, filtered through a bank of 4 Hz-wide sub-band filters. A Linear Discriminant Analysis classifier will be trained on these features.\n\nFor P300 detection, epochs will be averaged, and peak amplitude and latency features will be extracted. Classification performance will be validated using 10-fold cross-validation.\n\nExpected performance metrics include classification accuracy greater than 75% for 3-class motor imagery, information transfer rate greater than 15 bits/min, and P300 detection accuracy greater than 90%. Statistical significance will be assessed using repeated-measures ANOVA and post-hoc t-tests with α = 0.05.\n\nSafety & Feasibility:\n\nThe protocol uses a hybrid EEG montage with wet gel electrodes over the sensorimotor cortex, dry electrodes over frontal and upper trapezius muscle areas, and ear-EEG electrodes for reference and additional signal capture. The motor imagery paradigm includes 2-second rest intervals after each 4-second cue period, and the P300 response is measured in a separate auditory oddball paradigm.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement Placing EEG electrodes on the upper trapezius muscle instead of the scalp fails to capture brain signals necessary for motor imagery and P300 detection. The target physiological signals for EEG are generated by the brain, not skeletal muscles, making the data acquisition invalid and expected performance metrics (e.g., >75% MI accuracy, >90% P300 accuracy) unachievable. Fix: Reposition the dry electrodes to scalp areas such as frontal and parietal regions according to the international 10-20 system.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000081", "source_id": "52ccefd13bec", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "valid", "protocol": "Protocol: Continuous Blood Pressure Estimation via PTT from Synchronized PPG and ECG\n\nObjective: To estimate continuous blood pressure using pulse transit time derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals.\n\nEquipment: A single-lead clinical ECG module (e.g., AD8232) with pre-gelled Ag/AgCl electrodes in Lead II configuration (right arm, left leg). A reflective pulse oximeter sensor (e.g., MAX30102) operating at a wavelength of 940 nm (infrared), secured firmly to the distal phalanx of the index finger using a commercial clip to minimize motion artifact. Both sensors are connected to a common microcontroller (e.g., Arduino Uno) with a shared clock to ensure time-stamped, synchronized data acquisition. A validated, oscillometric cuff (e.g., Omron Platinum) is used to obtain reference blood pressure readings for calibration.\n\nSensor Placement & Configuration: ECG electrodes are placed in Lead II configuration with the right arm and left leg. The PPG sensor is secured to the distal phalanx of the index finger using a commercial clip to minimize motion artifact.\n\nData Acquisition Procedure: Both PPG and ECG are sampled at 100 Hz with 16-bit analog-to-digital conversion. Record 5 minutes of continuous, resting data in a seated position after a 5-minute acclimatization period. At the start of the recording, use the oscillometric cuff to obtain a reference brachial systolic (SBP) and diastolic blood pressure (DBP) reading for calibration.\n\nSignal Processing & Validation: ECG is band-pass filtered (0.5-40 Hz). PPG is low-pass filtered at 15 Hz to remove high-frequency noise. The R-peak of the ECG QRS complex is detected using a Pan-Tompkins derivative algorithm. The systolic peak of the PPG waveform is detected via a threshold-based algorithm on the first derivative. For each cardiac cycle, pulse transit time (PTT) is defined as the time delay from the ECG R-peak to the corresponding PPG systolic peak. A linear regression model, BP = α * PTT + β, is calibrated using the initial cuff-derived SBP and DBP and the simultaneously calculated mean PTT. This calibrated model is then applied to subsequent PTT values to generate continuous SBP and DBP estimates. After single-point calibration, the method is expected to track BP trends with a mean error of ±5 mmHg (±8 mmHg SD) for SBP and DBP.\n\nSafety & Feasibility: Accuracy degrades with significant changes in peripheral vascular tone (e.g., due to cold, stress) or with movement artifacts, requiring periodic recalibration.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000088", "source_id": "d0f22401c1fb", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nIMU-Based Wearable Motion Capture and Activity Recognition.\n\nObjective:\n\nTo perform motion capture using a custom wearable system composed of 9-axis and 6-axis IMUs, and to classify standardized human activities from synchronized inertial sensor data.\n\nEquipment:\n\nThe custom wearable system comprises three BNO055 9-axis IMUs from Bosch Sensortec, Germany, and two LSM6DSOX 6-axis IMUs from STMicroelectronics, Switzerland.\n\nThe BNO055 units provide fused orientation data at 100 Hz. The LSM6DSOX units are configured for raw data acquisition, with the accelerometer set to ±16g range and 12-bit resolution, and the gyroscope set to ±2000 dps with 16-bit resolution.\n\nAll sensors are synchronized via a central nRF52840 microcontroller from Nordic Semiconductor using a hardware trigger line, ensuring a temporal skew of less than 1 ms. Raw sensor data are streamed via Bluetooth Low Energy to a host PC. Signal processing is implemented in Python 3.9, and activity recognition uses a Random Forest classifier implemented with scikit-learn 1.2.\n\nSensor Placement & Configuration:\n\nThe wearable system uses three BNO055 9-axis IMUs and two LSM6DSOX 6-axis IMUs for motion capture. The BNO055 units provide fused orientation data at 100 Hz, while the LSM6DSOX units acquire raw accelerometer and gyroscope data at 50 Hz.\n\nThe LSM6DSOX accelerometer is configured to ±16g range with 12-bit resolution, and the gyroscope is configured to ±2000 dps with 16-bit resolution. All sensors are synchronized through the nRF52840 microcontroller using a hardware trigger line, maintaining a temporal skew of less than 1 ms.\n\nData Acquisition Procedure:\n\nMotion capture is performed using the custom wearable IMU system. Raw sensor data are streamed via Bluetooth Low Energy to a host PC.\n\nThe dataset includes 15 healthy adults performing 10 standardized activities, including walking, sitting, and stair climbing. The synchronized IMU data are used for activity recognition and validation with a leave-one-subject-out cross-validation protocol.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline begins with a 4th-order Butterworth low-pass filter with a 40 Hz cutoff to attenuate high-frequency noise from the accelerometer and gyroscope signals.\n\nFor the 9-axis data, a complementary filter is applied to fuse accelerometer, gyroscope, and magnetometer readings, providing drift-corrected orientation quaternions. Gravity components are removed from the accelerometer signals using the orientation estimates to isolate dynamic linear acceleration.\n\nFeature extraction is performed on 2-second sliding windows with 50% overlap. A total of 156 features are computed per window, including time-domain statistics such as mean, variance, and zero-crossings, frequency-domain features such as spectral energy and dominant frequency via FFT, and cross-axis correlations.\n\nA Random Forest classifier with 200 estimators is trained for activity recognition. Validation employs a leave-one-subject-out cross-validation protocol on the dataset of 15 healthy adults performing 10 standardized activities. Expected performance metrics are classification accuracy greater than 95% and macro-averaged F1-score greater than 0.93, with confusion matrix analysis used to identify inter-class confusion between similar activities such as walking and ascending stairs.\n\nSafety & Feasibility:\n\nThe protocol uses a custom wearable IMU system with synchronized acquisition through a central microcontroller and Bluetooth Low Energy streaming to a host PC. Temporal skew across sensors is maintained below 1 ms. The dataset is collected from 15 healthy adults performing 10 standardized activities.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content, specifically the Nyquist theorem requiring sampling rate to be at least twice the highest signal frequency. The LSM6DSOX is sampled at 50 Hz, giving a Nyquist frequency of 25 Hz, but the low-pass filter has a cutoff at 40 Hz, allowing frequencies up to 40 Hz to pass. Since 40 Hz exceeds 25 Hz, aliasing will corrupt the signals, making the experiment physically invalid. Fix: Increase the sampling rate of LSM6DSOX to at least 80 Hz to satisfy the Nyquist criterion for the 40 Hz filter cutoff.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000091", "source_id": "e2f748c1a454", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nSurface Electromyography Recording from the Dominant Upper Arm for Static Hand Gesture Recognition.\n\nObjective:\n\nTo record surface electromyography signals from the dominant upper arm of healthy adult participants and evaluate wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and a high-density grid for static hand gesture classification.\n\nEquipment:\n\nSurface electromyography signals will be recorded from 20 healthy adult participants, including 10 male and 10 female participants aged 25.5 ± 3.2 years, following ethical approval and written informed consent.\n\nThree electrode types will be evaluated in separate sessions: wet gel Ag/AgCl electrodes, Kendall MediTrace 100 series; dry stainless steel electrodes, TMSi DS24; and a high-density grid, OT Bioelettronica ELSCH032, with an 8x4 array.\n\nSignals will be acquired using a 16-bit g.tec g.USBamp biosignal amplifier with a sampling rate of 2048 Hz per channel and a band-pass filter set to 20–500 Hz. A 50 Hz notch filter will be applied to suppress power-line interference. The system will have a common-mode rejection ratio greater than 100 dB and input impedance greater than 100 MΩ.\n\nSensor Placement & Configuration:\n\nElectrodes will be placed over six key upper arm muscles according to SENIAM guidelines. The array will use an inter-electrode distance of 20 mm.\n\nA reference electrode will be placed on the olecranon. The wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and high-density grid will be evaluated in separate sessions.\n\nData Acquisition Procedure:\n\nParticipants will perform a set of 12 static hand gestures, including fist, pinch, and wrist flexion. Each gesture will be performed in 5-second trials.\n\nEach gesture will be repeated 10 times, with a 3-second rest interval between trials. sEMG signals will be recorded from the dominant upper arm using the three electrode types across separate sessions.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will include band-pass filtering from 20–450 Hz using a 4th-order Butterworth filter, segmentation into 250 ms windows with 50 ms overlap, extraction of time-domain features, and classification using a Linear Discriminant Analysis model.\n\nThe extracted time-domain features will include Root Mean Square, Mean Absolute Value, Waveform Length, and Zero Crossings.\n\nA 10-fold cross-validation strategy will be employed, with 80% of data used for training and 20% for testing. Validation performance will be assessed using overall accuracy and F1-score.\n\nThe wet gel Ag/AgCl electrodes will serve as the gold standard, achieving a mean classification accuracy of 94.2 ± 1.8%. The dry stainless steel electrodes and high-density array will yield accuracies of 91.5 ± 2.3% and 93.1 ± 2.0%, respectively, demonstrating the robustness of the signal processing pipeline across sensor types for reliable gesture recognition.\n\nSafety & Feasibility:\n\nParticipants will provide written informed consent, and the study will follow ethical approval. The protocol uses non-invasive sEMG electrodes placed over upper arm muscles according to SENIAM guidelines, with a reference electrode placed on the olecranon. A 3-second rest interval will be included between 5-second gesture trials.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement Placing sEMG electrodes on upper arm muscles (e.g., biceps brachii) does not generate physiological signals corresponding to hand gestures, as hand movements are primarily controlled by forearm muscles. This misplacement makes the reported classification accuracies (e.g., 94.2%) physically impossible for gesture recognition, rendering the experiment invalid. Fix: Place electrodes on forearm muscles instead of upper arm muscles to capture signals relevant to hand gestures.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000098", "source_id": "2ec6f075288e", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nSurface Electromyography Acquisition for Electrode Performance Evaluation in Static Hand Gesture Recognition.\n\nObjective:\n\nTo acquire surface electromyography signals using wet-gel Ag/AgCl electrodes and a dry stainless steel high-density electrode array, and to evaluate electrode performance for classification of static hand gestures.\n\nEquipment:\n\nTwo parallel sEMG acquisition systems will be used. For conventional recordings, eight wet-gel Ag/AgCl electrodes, Kendall™ 200 Series, will be used in a bipolar configuration. These signals will be amplified and digitized using a Delsys Trigno™ Avanti wireless system with gain of 1000, bandwidth of 20–450 Hz, 24-bit ADC resolution.\n\nFor high-density dry-electrode recordings, a 16-channel dry stainless steel electrode array from OT Bioelettronica will be used, arranged as an 8x2 grid with 10 mm inter-electrode distance. Signals from this array will be amplified using an OT Bioelettronica EMG-USB2+ amplifier with bandwidth of 10–750 Hz, 16-bit ADC resolution. Signal processing will be implemented in MATLAB.\n\nSensor Placement & Configuration:\n\nThe wet-gel Ag/AgCl electrodes will be placed in a bipolar configuration over the forearm flexor and extensor muscle groups, including the flexor digitorum superficialis and extensor digitorum communis, following SENIAM guidelines. A reference electrode will be placed on the lateral epicondyle.\n\nThe 16-channel dry stainless steel electrode array will be placed on the proximal forearm to capture high-density sEMG. The dry array will use an 8x2 grid configuration with 10 mm inter-electrode distance.\n\nData Acquisition Procedure:\n\nsEMG data will be collected from 10 participants performing 10 repetitions of 8 static hand gestures. Conventional wet-gel electrode recordings and dry high-density array recordings will be acquired concurrently using their respective amplifier systems.\n\nWet-gel electrode data will be sampled at 2000 Hz through the Delsys Trigno™ Avanti wireless system. Dry electrode array data will be sampled at 1000 Hz through the OT Bioelettronica EMG-USB2+ amplifier.\n\nSignal Processing & Validation:\n\nThe processing pipeline will include a 50 Hz notch filter to remove powerline interference, followed by a 4th-order Butterworth bandpass filter from 20–500 Hz. Signals will then be segmented into 250 ms windows with 50% overlap.\n\nFeature extraction will include Root Mean Square, Mean Absolute Value, Waveform Length, and 4th-order autoregressive coefficients. Classification will be performed using a Support Vector Machine with a radial basis function kernel.\n\nTen-fold cross-validation will be performed on data from the 10 participants. Expected performance metrics include classification accuracy greater than 92% for the wet-gel array and greater than 88% for the dry array, with F1-scores reported per gesture. System noise floor and common-mode rejection ratio will be characterized to validate signal quality.\n\nSafety & Feasibility:\n\nThe protocol uses non-invasive sEMG recordings from wet-gel Ag/AgCl electrodes and a dry stainless steel electrode array placed on the forearm according to SENIAM-guided muscle locations. A reference electrode will be placed on the lateral epicondyle. System noise floor and common-mode rejection ratio will be characterized to validate signal quality.", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem The sampling rate of 1000 Hz is less than twice the maximum signal frequency of 750 Hz (2 * 750 = 1500 Hz), causing aliasing and rendering the high-density sEMG data physically invalid for accurate signal reconstruction. Fix: Increase the sampling rate for the high-density system to at least 1500 Hz, such as 2000 Hz or higher.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000113", "source_id": "7792fa1b540f", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "valid", "protocol": "Protocol: Silent Speech Recognition Using Throat Microphone and IMU\nObjective: To perform silent speech recognition by capturing throat vibrations and jaw movements using a piezoelectric contact microphone and an inertial measurement unit (IMU).\nEquipment: Throat Microphone: A piezoelectric contact microphone (e.g., ThoroComm TC-35) with a frequency response of 100 Hz to 4 kHz. Inertial Measurement Unit (IMU): A 9-axis MEMS IMU (e.g., Bosch BNO055) with ±2000°/s gyroscope and ±4g accelerometer. Data Acquisition: A 24-bit analog-to-digital converter (ADC) system (e.g., National Instruments NI-9234) with simultaneous sampling and built-in anti-aliasing filters. Both sensors connect to the ADC via shielded cables.\nSensor Placement & Configuration: Throat Microphone: Mounted externally on the skin over the laryngeal prominence using medical-grade adhesive. IMU: Placed on the skin over the mental protuberance (chin) to capture jaw and neck articulatory movements.\nData Acquisition Procedure: Throat Microphone: Sampled at 8 kHz (Nyquist frequency: 4 kHz). A 50 Hz notch filter removes power-line interference, followed by a band-pass filter (80 Hz–3.8 kHz) to isolate speech-related frequencies. IMU: Accelerometer and gyroscope data sampled at 200 Hz (Nyquist frequency: 100 Hz). A low-pass filter at 40 Hz removes high-frequency mechanical noise. Data Collection: Participants perform 10 repetitions of 50 isolated silent phonemes (e.g., /a/, /b/, /k/) and 20 common words (e.g., \"hello,\" \"stop\") while sitting upright with minimal head movement. Each utterance lasts 1–2 seconds. Rest intervals of 3 seconds prevent muscle fatigue.\nSignal Processing & Validation: Throat Signal: Pre-emphasis filter (α=0.97), segmentation into 25 ms frames with 10 ms overlap, followed by Mel-Frequency Cepstral Coefficient (MFCC) extraction (13 coefficients + delta/acceleration). IMU Signal: Compute jerk (derivative of acceleration) and angular velocity magnitude. Extract time-domain features (mean, variance, peak amplitude) and frequency-domain features (spectral centroid, entropy) per frame. Feature Fusion: Concatenate MFCCs and IMU features per frame. Normalize features using z-score standardization. Validation: A bidirectional LSTM network (2 layers, 128 units) is trained on 80% of data, validated on 10%, and tested on 10%. Accuracy is reported as word error rate (WER) for continuous speech and classification accuracy for isolated phonemes. Realistic Accuracy Claim: Expected phoneme classification accuracy: 85–90% for within-speaker validation; continuous speech recognition WER: 25–35% for a 20-word vocabulary, acknowledging limitations from coarticulation and sensor noise.\nSafety & Feasibility: All adhesives are hypoallergenic. Sampling rates and filters ensure no aliasing. IMU range covers typical articulatory motion (±4g exceeds maximum jaw acceleration during speech, ~2g). Protocol duration limited to 30 minutes per session to avoid fatigue.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000124", "source_id": "7a8bdb24a2d2", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: sEMG-Based Hand Gesture Recognition Benchmark\nObjective: To establish a benchmark for classifying 10 distinct hand gestures using surface electromyography (sEMG), aiming for a mean classification accuracy of 95.0 ± 2.5%.\nEquipment: A 16-channel clinical-grade surface electromyography (sEMG) acquisition system (e.g., Delsys Trigno Avanti) with wireless sensors having a bandwidth of 20-450 Hz, common-mode rejection ratio (CMRR) > 80 dB, signal-to-noise ratio (SNR) > 60 dB, and sampling at 2048 Hz. Sixteen Ag/AgCl adhesive electrodes and a reference electrode.\nSensor Placement & Configuration: The participant's dominant forearm is cleaned with isopropyl alcohol. Sixteen electrodes are placed in a 4x4 grid over the extrinsic hand muscles following SENIAM guidelines. The reference electrode is placed on the lateral epicondyle. Electrode impedance is verified to be less than 10 kΩ.\nData Acquisition Procedure: The participant performs 10 distinct hand gestures (e.g., power grasp, index extension, wrist flexion) from a standardized set (e.g., NinaPro DB5). Each gesture is held for 5 seconds followed by 5 seconds of rest, with 10 repetitions per gesture, yielding a 100-trial dataset. A visual cue system guides timing.\nSignal Processing & Validation: Raw sEMG data is processed in MATLAB or Python. Preprocessing includes a 4th-order Butterworth bandpass filter (20-450 Hz) and a 50/60 Hz notch filter. Segmentation divides the 5-second gesture windows into 200 ms overlapping frames with a 100 ms step. Feature extraction involves time-domain features (RMS, Waveform Length, Slope Sign Changes) and frequency-domain features (Mean Power Frequency), resulting in a 112-dimensional feature vector per frame (7 features x 16 channels). Classification uses a 10-fold cross-validation scheme with a Linear Discriminant Analysis (LDA) classifier trained on 80% of data and tested on 20%, with classification accuracy as the primary metric.\nSafety & Feasibility: Safety is addressed by cleaning the skin with isopropyl alcohol and verifying electrode impedance to ensure proper contact and minimize skin irritation. Feasibility is supported by controlled conditions, standardized gestures, and a robust processing pipeline, with an expected classification accuracy of 95.0 ± 2.5% consistent with state-of-the-art studies.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000125", "source_id": "786f091585f1", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nMulti-Band FMCW Radar Monitoring for Non-Contact Vital Sign Estimation\n\nObjective:\n\nAssess non-contact vital sign monitoring performance across millimeter-wave radar bands using three FMCW radar modules and reference physiological recordings.\n\nEquipment:\n\nThe experimental setup will use three frequency-modulated continuous wave radar modules:\n\nA 77 GHz radar, Texas Instruments IWR1443, with 4 GHz bandwidth and 10 MSPS sampling rate.\n\nA 60 GHz radar, Infineon BGT60LTR11, with 5.5 GHz bandwidth and 8 MSPS sampling rate.\n\nA 24 GHz radar, Aconno ACN524, with 2 GHz bandwidth and 0.002 MSPS sampling rate.\n\nThe corresponding theoretical range resolutions will be 3.75 cm, 2.7 cm, and 7.5 cm, respectively. Each radar’s transmit power will be set to the maximum permissible level for in-lab operation, typically <10 dBm EIRP.\n\nReference recordings will be acquired using a chest-worn piezoelectric respiratory belt, ADInstruments MLT1132, and a pulse oximeter, Nonin 3150.\n\nSensor Placement & Configuration:\n\nThe three radar modules will be positioned 2.0 meters from a seated subject.\n\nThe range bin corresponding to the subject’s thorax will be identified as the peak amplitude in the static range profile. The phase signal will be extracted from this bin over time.\n\nThe reference respiratory belt will be worn on the chest, and the pulse oximeter will be used for simultaneous reference recording.\n\nData Acquisition Procedure:\n\nFor each radar, a 5-minute recording will be collected under stationary conditions.\n\nRaw I/Q data will be acquired from each radar and processed through a common pipeline. Simultaneous reference recordings will be collected using the chest-worn piezoelectric respiratory belt and pulse oximeter.\n\nSignal Processing & Validation:\n\nA 2D Fast Fourier Transform will first be applied to the raw I/Q data to generate a range-Doppler map.\n\nThe thorax range bin will be identified as the peak amplitude in the static range profile, and the phase signal will be extracted from this bin over time.\n\nTo isolate vital signs, the phase signal will be passed through a 5th-order Butterworth bandpass filter with dual passbands: 0.1–0.5 Hz for respiration rate and 0.8–2.0 Hz for heart rate.\n\nPeaks in the filtered signals’ power spectral density will be identified to estimate instantaneous respiration rate and heart rate.\n\nPerformance will be evaluated by computing the mean absolute error and Pearson’s correlation coefficient between radar-derived estimates and reference signals.\n\nIt is expected that the 77 GHz and 60 GHz systems will achieve heart-rate MAE <3 bpm and respiration-rate MAE <1 breath per minute, with r >0.95. The 24 GHz system may show slightly higher MAE due to its coarser range resolution.\n\nStatistical significance will be assessed using paired t-tests with p<0.05.\n\nSafety & Feasibility:\n\nThe protocol uses non-contact FMCW radar modules positioned 2.0 meters from a seated subject, with transmit power set to the maximum permissible level for in-lab operation, typically <10 dBm EIRP. Simultaneous reference recordings will be obtained using a chest-worn respiratory belt and pulse oximeter under stationary conditions.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The sampling rate of 0.002 MSPS (2 Hz) is below the Nyquist rate for the heart rate signal up to 2 Hz, which requires at least 4 Hz sampling to avoid aliasing, rendering vital sign measurements invalid. Fix: Increase the sampling rate of the 24GHz radar to at least 4 Hz, such as the original 2 MSPS.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000128", "source_id": "e5441b31828d", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "valid", "protocol": "Protocol: Silent Speech Recognition Using Throat Microphone and IMU\n\nObjective: To develop and validate a silent speech recognition system by fusing signals from a throat microphone and an inertial measurement unit (IMU), targeting applications in assistive communication.\n\nEquipment: Throat Microphone: Piezoelectric contact sensor (e.g., PCB Piezotronics 352C33) with a frequency response of 20 Hz to 10 kHz, sensitivity of 100 mV/g, and a dynamic range of ±50 g. IMU: 9-axis MEMS IMU (e.g., InvenSense ICM-20948) with accelerometer (±16 g range, 16-bit resolution) and gyroscope (±2000 dps range). Sampling rate set to 200 Hz. Data Acquisition: Multi-channel 24-bit analog-to-digital converter (ADC) (e.g., National Instruments NI-9234) with anti-aliasing filters. Throat microphone sampled at 16 kHz, IMU at 200 Hz. All data synchronized via a common trigger.\n\nSensor Placement & Configuration: Throat microphone adhered to the skin over the thyroid cartilage (Adam’s apple) using medical-grade adhesive, ensuring consistent contact with laryngeal vibrations. IMU affixed to the chin using a lightweight strap to monitor jaw kinematics; a secondary IMU on the forehead tracks head orientation for motion compensation.\n\nData Acquisition Procedure: Participant performs silent speech (whispering without vocalization) of predefined vocabulary (e.g., 10 common words) in a quiet room. Record 10 repetitions per word per participant, with 1-second intervals between utterances. Simultaneously capture throat vibration signals and IMU data, timestamped for synchronization.\n\nSignal Processing & Validation: Pre-processing involves applying bandpass filtering (50–4000 Hz for throat mic, 0.5–50 Hz for IMU) to remove noise and DC offsets, and normalizing signals to zero mean and unit variance. Feature extraction includes computing 13 Mel-frequency cepstral coefficients (MFCCs) with a 25 ms window and 10 ms shift for throat microphone, and extracting kinematic features (e.g., mean acceleration, angular velocity peaks, and jerk metrics) from each axis for IMU. Feature fusion concatenates MFCCs and IMU features into a unified feature vector per time frame, then applies principal component analysis (PCA) for dimensionality reduction. Classification uses a support vector machine (SVM) with radial basis function kernel on fused features, using 5-fold cross-validation, and evaluates performance on a held-out test set. Validation measures accuracy as the percentage of correctly classified words, with confusion matrices to analyze error patterns. Ensure all hardware and processing parameters adhere to physical constraints, such as sensor bandwidth and sampling theory, to guarantee robust data acquisition.\n\nSafety & Feasibility: Based on preliminary feasibility, the system is expected to achieve 85% ± 3% recognition accuracy for a 10-word silent vocabulary, acknowledging limitations due to inter-subject variability and environmental noise. This aligns with current literature on multi-sensor silent speech interfaces.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000138", "source_id": "30ed82df6710", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nConcurrent EEG Sensor Technology Comparison for Motor Imagery BCI and P300 Detection\n\nObjective:\n\nAcquire EEG data using three concurrent systems to compare wet gel, dry electrode, and ear-EEG sensor technologies during a cue-based motor imagery BCI paradigm and a separate P300 oddball task.\n\nEquipment:\n\nEEG data will be acquired using three concurrent systems:\n\nA 64-channel wet gel system, g.tec g.USBamp, g.tec medical engineering GmbH, used as the primary reference.\n\nA 32-channel dry electrode system, Cognionics Mobile 128, Cognionics, Inc.\n\nA 2-channel ear-EEG system, Natus EEG Ear Clips, Natus Medical Incorporated.\n\nAll systems will sample at 512 Hz with 24-bit ADC resolution. Hardware filters will set a bandwidth of 0.1–100 Hz, with notch filters at 50/60 Hz.\n\nSignal processing will be implemented in Python using MNE and scikit-learn.\n\nSensor Placement & Configuration:\n\nWet gel electrodes will be placed according to the international 10–20 system, focusing on central and parietal regions, including C3, Cz, C4, Pz, and related sites.\n\nThe 32-channel dry electrode system will be co-registered.\n\nThe 2-channel ear-EEG system will be placed in the left and right ear conchae.\n\nThe ground and reference electrodes will be placed at AFz and the left mastoid, respectively.\n\nData Acquisition Procedure:\n\nParticipants, N=15, will perform a cue-based motor imagery BCI paradigm involving imagined left hand, right hand, and feet movements.\n\nA separate oddball task will be performed for P300 detection.\n\nEEG data will be recorded concurrently from the wet gel, dry electrode, and ear-EEG systems during the experimental tasks.\n\nSignal Processing & Validation:\n\nFor the motor imagery task, data will be band-pass filtered from 8 to 30 Hz to isolate mu and beta rhythms. Artifact Subspace Reconstruction will be applied for motion and eye-blink artifact removal.\n\nCommon Spatial Pattern filtering will be used for feature extraction and optimized for each frequency band. A Linear Discriminant Analysis classifier will be trained on the spatially filtered features.\n\nFor P300 detection in the separate oddball task, data will be filtered from 0.5 to 40 Hz and segmented into epochs time-locked to stimuli. Features will be extracted from the mean amplitude in the 250–500 ms post-stimulus window.\n\nValidation will use a 10-fold cross-validation scheme stratified by participant. Performance will be reported as classification accuracy for the 3-class motor imagery task, Information Transfer Rate, and Cohen’s kappa coefficient.\n\nExpected performance is >75% accuracy for wet gel electrodes, >65% accuracy for dry electrodes, and >99.99% accuracy for the ear-EEG system.\n\nSafety & Feasibility:\n\nThe protocol uses concurrent EEG acquisition from wet gel, dry electrode, and ear-EEG systems during motor imagery and P300 tasks. Hardware filtering, artifact removal, and cross-validation will be used to support comparison across sensor technologies for practical BCI applications.", "three_class_category": "Physical / Hardware", "violated_constraint": "accuracy_impossibility", "violated_principle": "Unrealistic performance claim", "why_invalid": "The stated performance exceeds the physical and statistical limits of the sensing modality. Sensor noise, calibration uncertainty, physiological variability, and reference-device error prevent the claimed precision. In this sample, the problematic modification is: A 32-channel dry electrode system (Cognionics Mobile 128, Cognionics, Inc.) will be co-registered..", "minimal_fix": "Replace the unrealistic accuracy claim with a physically plausible performance target and include calibration, uncertainty, and reference-device error in validation.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000139", "source_id": "50172d3ff07d", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture for Upper and Lower Limb Activity Recognition\nObjective: To capture and classify human movement using 6-axis and 9-axis Inertial Measurement Units (IMUs) for robust activity recognition.\nEquipment: Four 6-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps), two 9-axis IMUs (adding magnetometer ±4900 µT), data logging unit with Bluetooth/SD card capability, and reference motion capture system (e.g., optical) for validation.\nSensor Placement & Configuration: Affix 6-axis IMUs to: (1) mid-sternum, (2) dominant wrist dorsum, (3) dominant thigh anterior, (4) dominant ankle lateral. Affix 9-axis IMUs to: (5) non-dominant wrist dorsum, (6) non-dominant ankle lateral. Sample all sensors at 200 Hz, sufficient to capture motion dynamics up to 100 Hz (Nyquist criterion) while managing power and data volume.\nData Acquisition Procedure: Perform a 30-second static calibration in a neutral standing pose to establish sensor biases and orientation. Follow with a dynamic calibration (e.g., figure-eight movements for magnetometers). Subject performs a predefined sequence of activities (e.g., sitting, standing, walking, stair ascent/descent, arm raises, object manipulation) for 3 minutes each, repeated 3 times. Include 10-second rest intervals. Simultaneously record ground truth motion using the optical system for a 60-second subset of activities focusing on joint angles.\nSignal Processing & Validation: Apply a 4th-order Butterworth low-pass filter (cutoff 20 Hz) to accelerometer data and a 25 Hz cutoff to gyroscope data to remove high-frequency noise. For the 9-axis units, use an extended Kalman filter to fuse magnetometer data with accelerometer/gyroscope for drift-corrected orientation (quaternion output). Segment data into 2-second sliding windows with 75% overlap. Extract time-domain (mean, variance, zero-crossing rate) and frequency-domain (spectral entropy, dominant frequency) features. Train and validate a classifier (e.g., Random Forest) using an 80/20 train-test split, ensuring activities from each trial are represented in both sets.\nSafety & Feasibility: This protocol uses commercially available sensor specifications. Validation is two-fold: (1) Internal consistency via repeated trials (intra-class correlation coefficient > 0.85), and (2) External validity by comparing IMU-derived joint angles against the optical reference (target RMSE < 5°). The multi-sensor, multi-axis approach ensures robustness for complex, real-world activities.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000147", "source_id": "a9721bc62913", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nMulti-Frequency FMCW Radar Evaluation for Non-Contact Vital Sign Monitoring\n\nObjective:\n\nEvaluate three commercially available FMCW radar modules for non-contact respiration rate and heart rate monitoring, using simultaneous clinical reference measurements for validation.\n\nEquipment:\n\nThree commercially available FMCW radar modules will be evaluated:\n\nA Texas Instruments IWR1443 operating at 77 GHz with 4 GHz bandwidth.\n\nA Texas Instruments IWR6843 operating at 60 GHz with 1.5 GHz bandwidth.\n\nA Texas Instruments AWR1642 operating at 24 GHz with 1 GHz bandwidth.\n\nThe radar systems will be configured with a sampling rate of 10 MSPS for the 77 GHz unit and 5 MSPS for the other units, yielding range resolutions of approximately 3.75 cm, 10 cm, and 15 cm, respectively.\n\nThe radar intermediate frequency signal will be captured using a National Instruments NI 6008 data acquisition card and processed offline in MATLAB.\n\nReference measurements will be acquired using a clinical-grade pulse oximeter, Masimo Radical-7, for heart rate and a capnograph, Philips Respironics NM3, for respiration rate.\n\nSensor Placement & Configuration:\n\nSubjects will be seated in a stationary chair at a distance of 1.5 meters from the radar antennas, within the specified detection range.\n\nThe radar antennas will be directed toward the subject’s thorax. The range bin corresponding to the thorax will be isolated during processing.\n\nReference heart rate and respiration rate measurements will be recorded simultaneously using the pulse oximeter and capnograph.\n\nData Acquisition Procedure:\n\nFor each trial, the radar intermediate frequency signal will be acquired using the National Instruments NI 6008 data acquisition card.\n\nA 60-second data segment will be analyzed for each trial. Simultaneous reference measurements will be collected using the Masimo Radical-7 pulse oximeter for heart rate and Philips Respironics NM3 capnograph for respiration rate.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will begin with a range-FFT to isolate the bin corresponding to the subject’s thorax.\n\nClutter will be removed using a high-pass filter with a 0.05 Hz cutoff. The phase of the complex signal in the selected range bin will be unwrapped and detrended to extract the micro-displacement waveform.\n\nThe micro-displacement waveform will then be bandpass filtered using a 4th-order Butterworth filter. For respiration rate, the passband will be 0.1–0.5 Hz. For heart rate, the passband will be 0.8–2.0 Hz.\n\nThe dominant frequency in each band will be identified using peak detection in the power spectral density computed with a 2048-point FFT.\n\nValidation will be performed against simultaneous reference measurements. Expected performance, based on prior literature, is a mean absolute error of ≤1.5 beats per minute for heart rate and ≤1.0 breaths per minute for respiration rate, with a Pearson correlation coefficient greater than 0.95 against the reference signals.\n\nBland–Altman analysis will be used to assess agreement and limits of agreement.\n\nSafety & Feasibility:\n\nThe protocol uses non-contact FMCW radar monitoring while subjects are seated in a stationary chair at 1.5 meters from the radar antennas. Clinical reference measurements will be collected simultaneously using a pulse oximeter and capnograph, and each trial will be evaluated using a 60-second segment.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The NI 6008 data acquisition card has a bandwidth of approximately 5 kHz, but the radar's IF signal frequencies are at least 10 kHz for the AWR1642 radar and up to 40 kHz for the IWR1443, so the card cannot capture the signal accurately, making the experiment physically impossible. Fix: Use a data acquisition card with bandwidth greater than the highest IF signal frequency, such as the PXIe-5171.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000168", "source_id": "066e856393c6", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture and Activity Recognition Benchmark\n\nObjective: To benchmark an IMU-based system for motion capture and activity recognition using specified hardware and procedures.\n\nEquipment: The system uses a 9-axis IMU module with an accelerometer (±16g range, 16-bit resolution, 1000 Hz max output data rate), gyroscope (±2000 dps range, 16-bit resolution, 1000 Hz max output data rate), and magnetometer (±4900 µT range, 16-bit resolution, 100 Hz output data rate). The processing unit is an on-board 32-bit microcontroller (e.g., ARM Cortex-M4) with a real-time clock and Bluetooth Low Energy (BLE) 5.0 for data streaming. Power is supplied by a rechargeable 3.7V Li-Po battery providing ≥8 hours of continuous operation.\n\nSensor Placement & Configuration: Five IMU nodes are placed on the participant using elastic straps: sternum, dominant wrist, non-dominant wrist, right thigh (mid-segment), and right shank (mid-segment). Sensors are oriented with the Z-axis aligned to the proximal-distal anatomical axis of each segment. Prior to recording, each IMU undergoes a 60-second static calibration for accelerometer and gyroscope bias estimation, with the participant standing in the N-pose (arms at sides, feet together).\n\nData Acquisition Procedure: All IMU nodes synchronize and sample at 200 Hz, which is above the Nyquist frequency for human motion and allows accurate capture of impact transients up to 100 Hz. Hardware synchronization via a shared trigger pulse ensures inter-sensor jitter < 1 ms. Participants perform a predefined sequence of 10 activities (e.g., walking,", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000170", "source_id": "a968fc9373f4", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG Recording for Motor Imagery and P300 BCI Tasks Using Wet, Dry, and Ear-EEG Systems\n\nObjective:\n\nAcquire EEG signals using wet gel, dry electrode, and ear-EEG systems to evaluate left/right hand motor imagery classification and P300 speller performance.\n\nEquipment:\n\nEEG signals will be acquired using a BioSemi ActiveTwo system with 64-channel wet gel Ag/AgCl electrodes at a sampling rate of 512 Hz with 24-bit ADC resolution, providing a bandwidth of DC to 134 Hz.\n\nSupplementary recordings will be obtained using a 16-channel g.tec g.SCARABEO dry electrode system and a 4-channel Natus Quantum ear-EEG device, both sampled at 500 Hz.\n\nSignal processing will be implemented in MATLAB R2022a using the EEGLAB and BCILAB toolboxes.\n\nSensor Placement & Configuration:\n\nElectrodes will be positioned according to the 10–20 system, with a focus on occipital regions, O1 and O2, for motor imagery, and frontal/parietal regions, Fz and Pz, for P300 detection.\n\nThe reference electrode will be placed at the right mastoid, and the ground electrode will be placed at AFz.\n\nData Acquisition Procedure:\n\nValidation will involve 20 healthy participants performing left/right hand motor imagery and a P300 speller task.\n\nEEG data will be recorded using the wet gel BioSemi ActiveTwo system, with supplementary recordings from the g.tec g.SCARABEO dry electrode system and the Natus Quantum ear-EEG device.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will begin with bandpass filtering between 1 and 40 Hz using a 4th-order Butterworth filter, followed by a 50 Hz notch filter.\n\nOcular and muscular artifacts will be removed using Independent Component Analysis.\n\nFor motor imagery, features will be extracted from the mu band, 8–12 Hz, and beta band, 13–30 Hz, using Common Spatial Patterns over 4-second epochs.\n\nFor P300 detection, features will be extracted using Morlet wavelet transforms from 200–600 ms post-stimulus epochs.\n\nA linear Support Vector Machine classifier will be trained on 70% of the data using stratified 10-fold cross-validation and tested on the remaining 30%.\n\nPrimary performance metrics will include classification accuracy, with targets of >75% for 2-class motor imagery and >90% for P300 row/column selection, Information Transfer Rate, and statistical significance assessed using repeated-measures ANOVA with p<0.05.\n\nThe wet gel system is expected to yield the highest accuracy, followed by dry and ear-EEG systems, with results reported as mean ± standard deviation across participants.\n\nSafety & Feasibility:\n\nThe protocol uses non-invasive EEG acquisition from healthy participants during motor imagery and P300 speller tasks. Wet gel, dry electrode, and ear-EEG systems will be compared using classification performance, Information Transfer Rate, and repeated-measures statistical analysis.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "Anatomical misplacement: sensors must be placed on anatomy that generates the target physiological signal. Motor imagery signals are primarily generated in the sensorimotor cortex (central regions C3, C4, Cz), not the occipital cortex (O1, O2). Placing electrodes on O1 and O2 would capture visual-related activity, not mu and beta rhythms essential for motor imagery, making it physically impossible to achieve the target classification accuracy of >75%. Fix: Revert the focus region for motor imagery to central regions (C3, C4, Cz).", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000177", "source_id": "0fe2e8c6d897", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\n77 GHz FMCW Millimeter-Wave Radar for Non-Contact Vital Sign Monitoring\n\nObjective:\n\nMonitor respiration rate and heart rate using a 77 GHz FMCW millimeter-wave radar sensor and validate radar-derived estimates against simultaneous ECG and respiratory belt reference signals. Testing the system's tolerance to extreme conditions, such as extreme temperatures, humidity, weather, etc.\n\nEquipment:\n\nVital sign monitoring will be performed using a 77 GHz FMCW millimeter-wave radar sensor, Texas Instruments IWR1443BOOST, operating with a 4 GHz bandwidth and yielding a theoretical range resolution of 3.75 cm.\n\nThe radar will operate with a chirp repetition rate of 100 Hz and a sampling rate of 2.5 MSPS.\n\nReference measurements will be acquired using a 3-lead electrocardiogram for heart rate and a respiratory inductance plethysmography belt for respiration rate.\n\nSensor Placement & Configuration:\n\nThe radar will be positioned 2.0 meters from a seated human subject.\n\nThe range FFT will be used to isolate the subject’s thoracic bin during signal processing.\n\nThe reference 3-lead ECG and respiratory inductance plethysmography belt will be recorded simultaneously.\n\nData Acquisition Procedure:\n\nData will be collected over a 5-minute recording under controlled, stationary conditions.\n\nRaw I/Q radar data will be acquired while the subject remains seated. Simultaneous reference heart rate and respiration rate measurements will be collected using the 3-lead ECG and respiratory inductance plethysmography belt. No temperature compensation is utilized.\n\nSignal Processing & Validation:\n\nThe raw I/Q data will be processed through a signal pipeline. Range FFT will be applied to the beat signal to isolate the subject’s thoracic bin, followed by phase extraction and unwrapping.\n\nA zero-phase 5th-order Butterworth bandpass filter will separate the vital signs, using 0.1–0.5 Hz for respiration and 0.8–2.0 Hz for heart rate.\n\nThe filtered phase signal will then be transformed using FFT to determine the dominant frequency corresponding to respiration rate and heart rate. Spectral peak detection with a minimum prominence threshold will be used to identify the fundamental frequencies.\n\nValidation will compare radar-derived vital signs against the reference signals using Pearson correlation coefficient and Bland–Altman analysis.\n\nExpected performance is a mean absolute error for respiration rate <0.5 breaths per minute and for heart rate <2.0 BPM, with correlation coefficients greater than 0.95 for both parameters under controlled, stationary conditions.\n\nSafety & Feasibility:\n\nThe protocol uses non-contact radar monitoring with the radar positioned 2.0 meters from a seated human subject. Reference measurements will be collected simultaneously using a 3-lead ECG and respiratory inductance plethysmography belt. During thunderstorm weather, with high humidity and extreme conditions ranging from -40 to 85 degrees Celsius, the system's limit capabilities were tested.", "three_class_category": "Physical / Hardware", "violated_constraint": "temperature_range", "violated_principle": "Operating temperature violation", "why_invalid": "The protocol requires the electronics to operate outside their rated temperature range. Under those conditions, sensor accuracy, oscillator stability, battery behavior, and circuit reliability cannot be assumed. In this sample, the problematic modification is: Vital sign monitoring was performed using a 77GHz FMCW millimeter-wave radar sensor (Texas Instruments IWR1443BOOST) operating with a 4GHz bandwidth, yielding a theoretical range resolution of 3.75 cm..", "minimal_fix": "Restrict the experiment to the rated component temperature range or use components rated and validated for the claimed environment.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000180", "source_id": "ac2386220b65", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture and Activity Recognition Benchmark\nObjective: To benchmark the accuracy of IMU-based motion capture and activity recognition against ground truth systems.\nEquipment: Six Bosch BNO055 9-axis IMU modules (3-axis accelerometer, gyroscope, magnetometer) with integrated sensor fusion. Modules are mounted in rigid, anatomically aligned housings with soft straps.\nSensor Placement & Configuration: Sensors are placed bilaterally on: (1) mid-thigh (anterior), (2) mid-shank (lateral), and (3) dorsum of foot. This configuration captures lower-limb kinematics for gait and activity analysis.\nData Acquisition Procedure: All sensors are synchronized and sampled at 50 Hz. This rate is above the Nyquist frequency for typical human motion (dominant frequencies < 20 Hz), preventing aliasing. Accelerometer range: ±16g (resolution: 0.004g). Gyroscope range: ±2000°/s (resolution: 0.0625°/s). These settings accommodate high-acceleration impacts and rapid rotations during activities like jumping. Prior to data collection, a 30-second stationary period is recorded for each sensor to establish the gravity vector and correct for accelerometer bias. Gyroscope bias is estimated from this period and subtracted in post-processing.\nSignal Processing & Validation: Data streams are aligned using a common hardware trigger timestamp. Raw accelerometer and gyroscope signals are passed through a 4th-order Butterworth low-pass filter with a 20 Hz cutoff frequency to remove high-frequency sensor noise and vibration artifacts. A Madgwick filter (gain β=0.1) fuses the filtered accelerometer and gyroscope data to estimate sensor orientation (quaternions) in a global frame, correcting for drift using the magnetometer where magnetic interference is minimal. For activity recognition, a 2-second sliding window (100 samples) with 50% overlap is used. Features include mean, variance, signal magnitude area, and dominant frequency from each axis, plus inter-sensor correlation coefficients. Orientation estimation error is expected to be < 5° RMS compared to optical tracking, with positional drift < 2% of distance traveled over 60 seconds of walking. A Support Vector Machine (SVM) classifier, trained on a subset of the data, is used to recognize activities (e.g., walking, running, sitting, stair ascent). Benchmark accuracy is reported as >92% F1-score on a held-out test set. The protocol is validated by simultaneous motion capture using an optical system (e.g., Vicon) as ground truth for kinematics, and by manual video annotation for activity labels.\nSafety & Feasibility: Not specified in the original protocol.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000188", "source_id": "7663f4ec570f", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nMulti-Frequency FMCW Radar Monitoring for Non-Contact Vital Sign Estimation\n\nObjective:\n\nEvaluate non-contact respiration rate and heart rate estimation using three frequency-modulated continuous wave radar modules operating at 24 GHz, 60 GHz, and 77 GHz.\n\nEquipment:\n\nThe experimental setup will use three FMCW radar modules:\n\nA 24 GHz system, Texas Instruments IWR1443, with 1.5 GHz bandwidth and 10 cm range resolution.\n\nA 60 GHz system, Infineon BGT60TR13C, with 5.6 GHz bandwidth and 2.7 cm range resolution.\n\nA 77 GHz system, Texas Instruments AWR1642, with 4 GHz bandwidth and 3.75 cm range resolution.\n\nAll systems will be configured with a chirp repetition frequency of 1 kHz and a sampling rate of 0.1 MSPS per chirp.\n\nReference measurements will be obtained using a clinical-grade capnograph, Philips Respironics NM3, for respiration rate and a pulse oximeter, Masimo Radical-7, for heart rate.\n\nSensor Placement & Configuration:\n\nThe radar modules will be positioned 2.0 meters from a stationary, seated human subject and aligned with the thorax.\n\nThe range bin corresponding to the subject’s thorax will be selected during signal processing.\n\nThe capnograph and pulse oximeter will be used concurrently as ground-truth reference devices.\n\nData Acquisition Procedure:\n\nData will be collected from 10 healthy volunteers in a controlled lab environment over 5-minute sessions.\n\nDuring each session, raw I/Q radar data will be acquired from the 24 GHz, 60 GHz, and 77 GHz radar systems while the subject remains stationary and seated.\n\nConcurrent reference respiration rate and heart rate data will be collected using the capnograph and pulse oximeter.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will begin with a 2D Fast Fourier Transform on the raw I/Q data to generate a Range-Doppler map.\n\nThe range bin corresponding to the subject’s thorax will be selected. Static clutter will be removed using a 3rd-order polynomial detrending filter.\n\nThe resulting phase signal will be processed through a zero-phase bandpass IIR filter with passbands of 0.1–0.5 Hz for respiration rate and 0.8–2.0 Hz for heart rate.\n\nA peak detection algorithm will be applied to the filtered signals’ power spectra to estimate instantaneous respiration rate and heart rate.\n\nPerformance will be evaluated using mean absolute error and Pearson correlation coefficient.\n\nIt is expected that the 77 GHz system will achieve the highest accuracy, with MAE <1 breath per minute for respiration rate and <2 beats per minute for heart rate, and r >0.95 for both vital signs, due to its superior phase noise performance and sensitivity to small displacements.\n\nSafety & Feasibility:\n\nThe protocol uses non-contact FMCW radar monitoring while healthy volunteers remain stationary and seated in a controlled lab environment. Ground-truth respiration rate and heart rate will be recorded concurrently using a clinical-grade capnograph and pulse oximeter.", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. For the 77 GHz radar system with a 4 GHz bandwidth and chirp duration of 1 ms (from 1 kHz chirp repetition), the maximum intermediate frequency is approximately 53.33 kHz, which exceeds the Nyquist frequency of 50 kHz for a sampling rate of 0.1 MSPS (100 kSPS), causing aliasing and making accurate signal reconstruction impossible. Fix: Increase the sampling rate to at least 0.2 MSPS (200 kSPS) to satisfy the Nyquist criterion for the highest frequency signal.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000189", "source_id": "7321638af989", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "valid", "protocol": "Protocol: EEG-BCI Motor Imagery Classification Protocol\nObjective: To classify kinesthetic motor imagery of left hand, right hand, and feet movements using an EEG-based brain-computer interface.\nEquipment: Use a research-grade EEG system (e.g., g.tec g.USBamp) with 16 active Ag/AgCl electrodes. Place electrodes according to the international 10-20 system over the sensorimotor cortex: FC3, FC1, FCz, FC2, FC4, C3, C1, Cz, C2, C4, CP3, CP1, CPz, CP2, CP4, and Pz. Use a right mastoid reference and AFz ground. Set sampling rate to 500 Hz. Apply a 0.1–40 Hz bandpass filter and a 50/60 Hz notch filter to remove line noise.\nSensor Placement & Configuration: Electrodes are placed according to the international 10-20 system over the sensorimotor cortex at positions FC3, FC1, FCz, FC2, FC4, C3, C1, Cz, C2, C4, CP3, CP1, CPz, CP2, CP4, and Pz. Reference electrode on the right mastoid, ground electrode at AFz.\nData Acquisition Procedure: Participants perform kinesthetic motor imagery (MI) of left hand, right hand, and feet movements. Each trial consists of a 2-second fixation cross, a 1-second cue (arrow indicating MI class), a 4-second MI period, and a 3-second rest. Record 100 trials per class (300 total) in randomized order across 3 sessions to prevent fatigue.\nSignal Processing & Validation: Preprocessing involves re-referencing to common average and applying Independent Component Analysis (ICA) to remove ocular and muscular artifacts. Feature extraction segments data from 0.5–3.5 seconds post-cue, computes bandpower in mu (8–12 Hz) and beta (13–30 Hz) rhythms using a 5th-order Butterworth filter, and applies Common Spatial Patterns (CSP) to maximize variance between classes, retaining 6 spatial filters (3 per class). Classification uses a 10x10-fold cross-validated linear discriminant analysis (LDA) on CSP features, with accuracy reported as mean ± standard deviation across folds. Validation ensures all hardware impedance is <20 kΩ, performs within-session and cross-session evaluation to assess robustness, and confirms statistical significance of above-chance accuracy (33.3%) via binomial test.\nSafety & Feasibility: Ensure electrode impedance is below 20 kΩ to maintain signal quality. Use multiple sessions with breaks to prevent participant fatigue. Realistic expected accuracy for a 3-class problem is 65–80%, dependent on participant training and signal quality; do not claim >85% without extensive subject-specific calibration and validation.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000191", "source_id": "ba24a41d00d9", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nSurface Electromyography Recording for Static Leg Gesture Classification\n\nObjective:\n\nRecord surface electromyography signals from the dominant forearm of 10 healthy participants during six static leg gestures and compare classification performance across three sensor configurations.\n\nEquipment:\n\nThe study will include 10 healthy participants, including 5 male and 5 female participants aged 25±3 years.\n\nThree sensor configurations will be used in randomized order:\n\nFour wet gel Ag/AgCl electrodes, Kendall H124SG.\n\nFour dry stainless steel electrodes, Delsys Trigno Dry electrodes.\n\nA 16-channel high-density dry electrode array, Delsys Trigno HD sensor.\n\nAll signals will be acquired using a Delsys Trigno Avanti system, sampled at 2000 Hz with a 16-bit ADC, and bandpass filtered in hardware from 20 to 450 Hz.\n\nSignal processing will be implemented in MATLAB.\n\nSensor Placement & Configuration:\n\nThe forearm skin will be prepared with abrasive gel and alcohol.\n\nWet gel Ag/AgCl electrodes will be placed over the flexor digitorum superficialis, extensor digitorum communis, flexor carpi radialis, and extensor carpi radialis longus.\n\nDry stainless steel electrodes will be placed in a similar monopolar configuration.\n\nThe 16-channel high-density dry electrode array will be placed circumferentially around the maximum forearm girth.\n\nA reference electrode will be placed on the olecranon process.\n\nData Acquisition Procedure:\n\nSurface electromyography signals will be recorded from the dominant forearm during six static leg gestures: rest, knee flexion, knee extension, ankle dorsiflexion, ankle plantarflexion, and toe extension.\n\nFor each participant, signals will be acquired using the three sensor configurations in randomized order.\n\nSignal Processing & Validation:\n\nRaw sEMG data will be digitally bandpass filtered using a 2nd-order Butterworth filter from 20 to 450 Hz and notch-filtered at 50 Hz.\n\nSignals will be segmented into 250 ms windows with 50 ms overlap.\n\nFor each window, time-domain and frequency-domain features will be extracted. Time-domain features will include root mean square, waveform length, and zero crossings. Frequency-domain features will include mean power frequency and median frequency.\n\nA linear discriminant analysis classifier will be trained using 10-fold cross-validation on the feature sets from each sensor configuration independently.\n\nClassification performance will be evaluated using overall accuracy and macro-averaged F1-score.\n\nExpected performance for the wet gel and high-density configurations is >95% accuracy, while the dry electrode configuration is expected to achieve >90% accuracy, with the high-density array providing superior robustness to electrode shift.\n\nSafety & Feasibility:\n\nThe protocol uses non-invasive sEMG recording from healthy participants, with forearm skin preparation using abrasive gel and alcohol. Electrode configurations will be tested in randomized order, and a reference electrode will be placed on the olecranon process.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement sEMG sensors placed on forearm muscles cannot generate physiological signals for leg gestures, as leg movements are controlled by leg muscles (e.g., quadriceps, hamstrings), not forearm muscles, making the experiment physically invalid. Fix: Either change the sensor placement to appropriate leg muscles or revert the gestures to hand gestures.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000206", "source_id": "2f956bb4792c", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol:\n\nSilent Speech Recognition Using a Contact Microphone and IMU\n\nObjective:\n\nAcquire synchronized contact microphone and IMU signals from five healthy participants during silent articulation, and classify silent utterances from a 100-word vocabulary using combined acoustic and laryngeal kinematic features.\n\nEquipment:\n\nData will be collected from five healthy participants, including 3 male and 2 female participants aged 25–35.\n\nA MEMS contact microphone, Knowles SPH0645LM4H-B, with a bandwidth of 50 Hz–10 kHz, will be used to capture subvocalization-related vibrations.\n\nA 9-axis inertial measurement unit, Bosch BMX055, will be used to capture laryngeal kinematics. The IMU will include an accelerometer with ±16 g range, a gyroscope with ±2000°/s range, and a magnetometer with ±1300 µT range.\n\nSignals will be acquired using a custom 8-bit ADC, Texas Instruments ADS1299. Audio will be sampled at 32 kHz, and IMU data will be sampled at 200 Hz. All channels will be synchronized using a common clock.\n\nSensor Placement & Configuration:\n\nThe MEMS contact microphone will be affixed over the laryngeal prominence using medical-grade adhesive.\n\nThe 9-axis IMU will be secured adjacent to the microphone to capture laryngeal kinematics.\n\nData Acquisition Procedure:\n\nParticipants will be seated and instructed to silently articulate a curated vocabulary of 100 words without vocalization.\n\nThe dataset will include 20 words with 5 repetitions per word. For each silent utterance, a 2.5-second epoch will be extracted.\n\nAudio and IMU signals will be acquired simultaneously using the synchronized acquisition configuration.\n\nSignal Processing & Validation:\n\nThe raw microphone signal will be bandpass filtered from 80 to 4000 Hz using a 4th-order Butterworth filter and amplitude-normalized.\n\nThe IMU accelerometer and gyroscope data will be low-pass filtered at 20 Hz using a 2nd-order Butterworth filter to isolate laryngeal movement.\n\nFrom the acoustic channel, 13 Mel-frequency cepstral coefficients and their first and second derivatives, totaling 39 features, will be computed per 25 ms frame with a 10 ms hop.\n\nFrom the IMU, 9-channel time-domain features, including mean, variance, and zero-crossing rate, and spectral entropy will be computed, yielding 27 features per epoch.\n\nThe 66 features will be concatenated per frame and fed into a bidirectional long short-term memory network with two hidden layers of 128 units, followed by a softmax classifier for word identification.\n\nValidation will use a participant-independent 5-fold cross-validation strategy. Expected performance metrics include classification accuracy ≥85% for the 100-word vocabulary, with per-class F1-scores reported. Robustness will be assessed by measuring accuracy degradation under simulated background muscle noise.\n\nA latency of <500 ms per utterance for real-time inference will be targeted.\n\nSafety & Feasibility:\n\nThe protocol uses a contact microphone attached with medical-grade adhesive over the laryngeal prominence and an adjacent IMU for laryngeal kinematic recording. Participants will remain seated during silent articulation, and real-time inference latency is targeted at <500 ms per utterance.", "three_class_category": "Signal & Sampling", "violated_constraint": "adc_resolution", "violated_principle": "ADC resolution limitation", "why_invalid": "The ADC resolution is too coarse for the expected signal amplitude. The quantization step can exceed meaningful physiological signal variations, preventing reliable measurement. In this sample, the problematic modification is: Data was collected from five healthy participants (3 male, 2 female; age 25-35)..", "minimal_fix": "Use a higher-resolution ADC and, where needed, an analog front-end with appropriate gain so that the expected low-amplitude signal can be resolved.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000212", "source_id": "aac54599607d", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Estimation Using Wearable PPG and ECG Sensors\n\nObjective:\n\nEstimate continuous blood pressure using a custom wearable device integrating photoplethysmography and electrocardiography sensors, with pulse transit time converted to blood pressure through subject-specific calibration.\n\nEquipment:\n\nThe custom wearable device will integrate PPG and ECG sensors, with the PPG sensor positioned on the wrist and secured using a stainless steel watch band.\n\nThe PPG module will use an ADPD4101 analog front-end, Analog Devices, configured for green and infrared LED wavelengths at 525 nm and 940 nm, respectively. PPG will be sampled at 125 Hz with 20-bit resolution and a 0.5–10 Hz bandwidth.\n\nThe ECG module will use a single-lead chest patch with Ag/AgCl electrodes and an ADS1299 analog front-end, Texas Instruments, for acquisition at 1000 Hz with 24-bit resolution and a 0.05–150 Hz bandwidth.\n\nMulti-lead ECG data for morphological validation will be acquired separately using a BioSemi ActiveTwo system, BioSemi B.V. Reference continuous blood pressure will be measured using a Finapres Nova, Finapres Medical Systems, non-invasive continuous BP system.\n\nSensor Placement & Configuration:\n\nThe PPG sensor will be positioned on the wrist and secured with a stainless steel watch band.\n\nThe ECG module will be configured as a single-lead chest patch using Ag/AgCl electrodes.\n\nMulti-lead ECG data will be acquired separately using the BioSemi ActiveTwo system for morphological validation.\n\nData Acquisition Procedure:\n\nValidation will be conducted on 20 healthy adults aged 25±3 years.\n\nParticipants will complete a protocol involving rest, mild exercise, and post-exercise recovery. The mild exercise condition will consist of cycling at 50 W.\n\nDuring a 5-minute resting baseline, reference blood pressure will be measured using the Finapres Nova system to derive the subject-specific calibration model.\n\nSignal Processing & Validation:\n\nThe signal processing pipeline will begin with bandpass filtering to remove baseline wander and high-frequency noise. PPG will be filtered from 0.5 to 5 Hz, and ECG will be filtered from 5 to 20 Hz.\n\nECG R-peaks will be detected using the Pan-Tompkins algorithm. For the PPG signal, the pulse wave peak and foot, or onset, will be identified using a second-derivative-based method.\n\nPulse Transit Time will be calculated as the time interval between the ECG R-peak and the corresponding PPG foot at the peripheral site.\n\nPTT will be converted to blood pressure using a subject-specific calibration model, BP = α*ln(PTT) + β. The coefficients α and β will be derived by linear regression against the Finapres Nova reference during the 5-minute resting baseline.\n\nThe primary performance metric will be the mean error and standard deviation of the estimated systolic and diastolic blood pressure against the Finapres reference. Performance will be evaluated against the Association for the Advancement of Medical Instrumentation standard requiring mean error ≤ ±5 mmHg and standard deviation ≤8 mmHg.\n\nThe expected Pearson correlation coefficient between PTT and reference blood pressure is >0.85.\n\nSafety & Feasibility:\n\nThe protocol uses wearable PPG and single-lead ECG sensing during rest, cycling at 50 W, and post-exercise recovery in healthy adults. The wrist PPG sensor will be secured with a stainless steel watch band, and reference continuous blood pressure will be obtained using the Finapres Nova system.", "three_class_category": "Perception & Anatomy", "violated_constraint": "optical_obstruction", "violated_principle": "Optical signal-path obstruction", "why_invalid": "PPG relies on light transmission/reflection; opaque obstacles block optical path. Stainless steel is opaque to green (525 nm) and infrared (940 nm) light, completely blocking the optical path, so no PPG signal can be acquired, rendering PTT calculation and BP estimation impossible as per the protocol's reliance on PPG data. Fix: Replace the stainless steel watch band with a non-opaque securing method, such as a silicone strap, to ensure unobstructed light transmission.", "minimal_fix": "Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000241", "source_id": "56c4e21f404a", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "valid", "protocol": "Protocol:\n\nContinuous blood pressure tracking using synchronized photoplethysmography (PPG) and electrocardiography (ECG) to derive pulse transit time (PTT) for beat-to-beat estimation.\n\nObjective:\n\nTo continuously estimate systolic (SBP) and diastolic blood pressure (DBP) from PTT derived from ECG and PPG signals.\n\nEquipment:\n\nBiopac MP160 or equivalent medical-grade physiological monitoring system\n\nECG module with standard 3-lead Ag/AgCl electrodes\n\nFinger-clip PPG sensor with infrared LED (940 nm) and photodetector\n\nSensor Placement & Configuration:\n\nECG electrodes placed on right arm, left arm, and left leg (Lead II configuration)\n\nPPG sensor attached to the participant’s index finger with secure and consistent contact\n\nAll sensors synchronized via system clock for accurate PTT calculation\n\nData Acquisition Procedure:\n\nContinuous ECG and PPG recording during rest, activity, or controlled perturbations\n\nSampling rates sufficient for accurate R-peak and pulse waveform detection (ECG ≥ 500 Hz, PPG ≥ 100 Hz)\n\nData streamed to acquisition software for real-time or offline analysis\n\nSignal Processing & Validation:\n\nECG filtered (0.5–40 Hz) to remove baseline drift and noise\n\nR-peak detection via Pan-Tompkins algorithm\n\nPPG filtered (0.5–8 Hz) and pulse wave foot identified via second-derivative method\n\nPTT computed as time interval between ECG R-peak and corresponding PPG pulse foot\n\nCalibration performed using reference cuff-based BP measurements\n\nValidation against continuous non-invasive reference (e.g., Finapres Nova) using mean error (ME), standard deviation of error (SDE), correlation coefficient (r), and Bland-Altman analysis\n\nSafety & Feasibility:\n\nNon-invasive sensors ensure participant comfort and minimal risk\n\nFinger and limb placement allows free movement without interfering with natural activity\n\nSystem suitable for continuous BP monitoring over extended sessions in clinical or laboratory environments", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000244", "source_id": "a062adbf629b", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "valid", "protocol": "Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit (IMU)\n\nObjective: To develop a benchmark dataset for silent speech recognition by capturing sub-vocalized speech using a throat microphone and accompanying head movement data via an IMU.\n\nEquipment: A commercially available piezoelectric contact microphone (e.g., Throat Mic Pro) with a frequency response of 50 Hz to 4 kHz, sensitivity of -40 dBV/Pa, and integrated preamplifier. A 9-axis MEMS IMU (accelerometer, gyroscope, magnetometer) with ±16g accelerometer range, ±2000 dps gyroscope range, and a sampling rate capability of up to 200 Hz. A 24-bit multi-channel audio interface for simultaneous analog microphone and digital IMU data capture. A standard PC for real-time data logging and offline processing.\n\nSensor Placement & Configuration: The throat microphone is affixed firmly with medical adhesive tape over the participant's laryngeal prominence (Adam's apple). The IMU is secured to the participant's forehead or temple using a headband to capture head kinematics correlated with articulation.\n\nData Acquisition Procedure: A 10-second silence period is recorded to establish a noise floor, and the IMU is calibrated for zero offset in a static position. Participants are instructed to silently articulate a predefined set of isolated words and short phrases. Data is recorded with the throat microphone at 8 kHz sampling rate and the IMU at 100 Hz sampling rate, synchronized via a common TTL trigger.\n\nSignal Processing & Validation: The throat mic signal is bandpass filtered (80 Hz - 3.5 kHz) to remove low-frequency motion artifact and", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000246", "source_id": "0c975e3e3a7b", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG Recording for Motor Imagery and P300 Detection Using Wet, Dry, and Ear-EEG Systems\n\nObjective:\n\nAcquire EEG data using wet gel, dry electrode, and ear-EEG systems to evaluate three-class motor imagery classification and binary P300 detection.\n\nEquipment:\n\nEEG data will be acquired using three electrode systems:\n\nA 64-channel actiCHamp system, Brain Products GmbH, with wet gel Ag/AgCl electrodes, EASYCAP GmbH.\n\nA 32-channel dry electrode cap, Cognionics, Inc., with flexible, spring-loaded gold-plated sensors.\n\nA 24-channel ear-EEG device, Natus Medical, Inc., with in-ear and around-ear dry electrodes.\n\nAll systems will sample at 500 Hz with 24-bit resolution and a hardware bandpass filter of 0.01–100 Hz. An additional 100 Hz notch filter will be applied online to suppress power-line interference.\n\nOffline processing will be performed in MATLAB R2023b using the EEGLAB and BCILAB toolkits.\n\nSensor Placement & Configuration:\n\nWet gel Ag/AgCl electrodes will be arranged according to the international 10–20 system.\n\nThe dry electrode cap will use flexible, spring-loaded gold-plated sensors.\n\nThe ear-EEG device will use in-ear and around-ear dry electrodes.\n\nData quality will be supported through impedance checks, with wet electrode impedances kept below 5 kΩ.\n\nData Acquisition Procedure:\n\nParticipants will perform a motor imagery task involving left hand, right hand, and foot movements cued by visual stimuli.\n\nEach task window will last 10 seconds, including 2 seconds of cue presentation followed by 8 seconds of imagery.\n\nEEG data will be recorded from the wet gel, dry electrode, and ear-EEG systems during the task.\n\nSignal Processing & Validation:\n\nData will be re-referenced to the average reference and bandpass filtered from 0.5 to 40 Hz using a 4th-order zero-phase Butterworth filter.\n\nArtifact rejection will be performed using amplitude thresholds of ±100 µV and independent component analysis.\n\nFor motor imagery, Common Spatial Patterns will be applied to the parietal electrodes, including Pz, POz, and adjacent electrodes, to extract mu rhythms from 8 to 12 Hz and beta rhythms from 13 to 30 Hz. Motor imagery features will be extracted per trial using the log-variance of CSP-filtered signals.\n\nFor P300 detection, data from parietal electrodes, including Pz and POz, will be epoched from -100 to 600 ms relative to stimulus onset, baseline-corrected, and averaged. P300 features will be extracted using mean amplitude between 250 and 500 ms.\n\nA Linear Discriminant Analysis classifier will be trained and validated using 5-fold cross-validation.\n\nExpected performance metrics include classification accuracy >70% for three-class motor imagery and >80% for binary P300 detection. Information Transfer Rate will be calculated from the confusion matrix.\n\nSafety & Feasibility:\n\nThe protocol uses non-invasive EEG acquisition with wet gel, dry electrode, and ear-EEG systems. Data quality will be supported through wet-electrode impedance checks, online notch filtering, amplitude-threshold artifact rejection, and independent component analysis.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement Motor imagery generates mu (8–12 Hz) and beta (13–30 Hz) rhythms primarily in the sensorimotor cortex (C3, Cz, C4). Applying CSP to parietal electrodes (Pz, POz) would not capture these rhythms, making feature extraction and classification physically impossible as the target physiological signal is absent. Fix: Apply CSP to sensorimotor cortex channels (C3, Cz, C4) instead of parietal electrodes.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000248", "source_id": "e8e1c7343fe6", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol: Multimodal Silent Speech Interface via Contact Microphone and Inertial Measurement Unit Fusion\n\nObjective:\nTo construct and evaluate a silent speech interface system that captures subvocalization signals and laryngeal/jaw kinematics to achieve sequence recognition with a target word error rate (WER) of <15% and a keyword spotting F1-score >0.85.\n\nEquipment:\n\nKnowles SPU1410LR5H-QB MEMS contact microphone (Sensitivity: -42 dBV/Pa; Bandwidth: 80 Hz – 4 kHz)\n\nBosch BMI270 9-axis inertial measurement unit (IMU)\n\nTexas Instruments ADS1299 analog front-end\n\nCustom LabVIEW interface for synchronization and logging\n\nPython-based signal processing pipeline\n\nMedical adhesive\n\nSensor Placement & Configuration:\n\nContact Microphone: Secured over the thyroid cartilage using medical adhesive; digitized at 16 kHz with 24-bit resolution via the ADS1299.\n\nInertial Measurement Unit (IMU): Affixed adjacent to the microphone; configured to stream accelerometer (±16 g), gyroscope (±2000 dps), and magnetometer data at 10 Hz via I2C.\n\nData Acquisition Procedure:\n\nParticipants: 15 subjects (8 male, 7 female, ages 20–45).\n\nExperimental Task: Participants perform silent speech using a 100-word vocabulary comprising digits, commands, and phonemes.\n\nRepetitions: 10 repetitions per word.\n\nSynchronization: All data streams are synchronized and logged via the custom LabVIEW interface.\n\nSignal Processing & Validation:\n\nAudio Channel: Processed with a 2nd-order Butterworth bandpass filter (80–3800 Hz); extraction of 13 Mel-frequency cepstral coefficients (MFCCs) using a 25 ms window and 10 ms hop.\n\nIMU Channel: Low-pass filtered at 20 Hz; extraction of statistical features (mean, variance, peak amplitude) per 100 ms window aligned with MFCC frames.\n\nModeling: Concatenated multimodal features are processed through a bidirectional LSTM with a CTC loss layer.\n\nValidation: Speaker-dependent 10-fold cross-validation scheme measuring WER and F1-score.\n\nSafety & Feasibility:\n\nImplementation of medical-grade adhesive for skin-contact sensors.\n\nFeasibility assessment based on 1,500 trials per participant.\n\nComparative evaluation of the fused multimodal system against isolated microphone and IMU modalities.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The IMU sampling rate of 10 Hz results in a Nyquist frequency of 5 Hz, which is lower than the 20 Hz low-pass filter cutoff, causing aliasing and making accurate signal reconstruction impossible. Fix: Increase the IMU sampling rate to at least 40 Hz to satisfy the Nyquist criterion for a 20 Hz low-pass filter.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000252", "source_id": "c33bb72d9ec1", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG data will be acquired using a g.tec g.USBamp amplifier connected to wet, dry, and ear-EEG electrodes during a cue-based motor imagery paradigm and a separate P300 detection pipeline.\n\nObjective:\n\nThe objective is to record EEG signals for motor imagery classification and P300 detection, compare performance across wet, dry, and ear-EEG electrode types, and benchmark classification performance using the BCI Competition IV 2a dataset and online testing with healthy participants.\n\nEquipment:\n\nA g.tec g.USBamp amplifier will be used with a 24-bit ADC, 256 Hz sampling rate, and 0.1–100 Hz acquisition bandpass. The electrode types will include g.LADYbird active wet gel electrodes, g.SCARABEO active dry electrodes, and g.EARline ear-EEG electrodes. Signal processing will be implemented in MATLAB using the BBCI toolbox.\n\nSensor Placement & Configuration:\n\nThe g.LADYbird active wet gel electrodes will be placed at Fz, C3, Cz, C4, Pz, and Oz. The g.SCARABEO active dry electrodes will be placed at F3, F4, CP3, and CP4. The g. electrodes will be placed on radial artery area. The scalp electrode montage will follow the international 10–20 system. Wet electrode impedances will be maintained below 5 kΩ.\n\nData Acquisition Procedure:\n\nEEG will be recorded during a cue-based motor imagery paradigm involving left hand, right hand, and feet imagery. Each trial will last 2 seconds, with a 1-second inter-trial interval. Online testing will be conducted with 10 healthy participants. Validation will also use the BCI Competition IV 2a dataset for benchmarking.\n\nSignal Processing & Validation:\n\nRaw EEG will be bandpass filtered from 5–30 Hz using a 4th-order Butterworth filter and re-referenced to the common average. For motor imagery classification, epochs from -0.5 to 2.5 seconds relative to cue onset will be extracted. Common Spatial Patterns will be used to extract features from mu-band signals at 8–12 Hz and beta-band signals at 13–30 Hz.\n\nFor P300 detection, a separate pipeline will apply a 1–12 Hz bandpass filter and extract epochs from 0 to 800 ms after stimulus onset. Features will consist of downsampled epoch amplitudes at 20 Hz. Classification will be performed using Linear Discriminant Analysis with 10-fold cross-validation.\n\nPrimary performance metrics will include classification accuracy, with targets of >70% for 3-class motor imagery and >80% for the P300 speller, as well as information transfer rate. Statistical significance will be assessed using repeated-measures ANOVA to compare performance across wet, dry, and ear-EEG electrode types.\n\nSafety & Feasibility:\n\nThe study will involve non-invasive EEG recording using wet, dry, and ear-EEG electrodes. Wet electrode impedances will be kept below 5 kΩ. Online testing will be supplemented by benchmarking on an established dataset, and feasibility will be assessed through classification accuracy, information transfer rate, and statistical comparison across electrode types.", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement: Sensor must be placed on anatomy that generates the target physiological signal. EEG signals are generated by brain activity and require electrode placement on the scalp or near the head (e.g., concha for ear-EEG). Placing electrodes on the wrist, which is a limb, will not capture EEG signals, making data acquisition for motor imagery and P300 detection physically impossible and invalid for brain-computer interface applications. Fix: Move the ear-EEG electrodes back to the concha or another valid head location such as the earlobe or mastoid process.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000259", "source_id": "142104d1965d", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: sEMG-Based Hand Gesture Recognition Benchmark\nObjective: To benchmark a sEMG-based hand gesture recognition system using a standardized experimental protocol.\nEquipment: A 16-channel wireless sEMG system (e.g., Delsys Trigno Avanti) with Ag/AgCl dry electrodes will be used. The system has a bandwidth of 20-450 Hz, a sampling rate of 1000 Hz (well above the Nyquist frequency for the 250 Hz upper bound of sEMG), and a input-referred noise floor of <1 μV RMS.\nSensor Placement & Configuration: Electrodes will be placed on the dominant forearm according to SENIAM guidelines: 8 pairs over the flexor digitorum superficialis, flexor carpi ulnaris, extensor digitorum, and extensor carpi radialis longus/brevis, with a reference electrode on the olecranon.\nData Acquisition Procedure: Participants (N=20) will be seated comfortably. Skin will be cleaned with alcohol wipes, and electrode-skin impedance verified to be <10 kΩ. Participants will perform a set of 7 static hand gestures (e.g., rest, fist, wrist extension, wrist flexion, fine pinch, index point, tripod grasp). Each gesture will be held for 5 seconds, followed by a 5-second rest, repeated 10 times per gesture in a randomized block design. A 2-minute rest is provided between blocks to minimize fatigue. A trigger signal will synchronize gesture onset with the sEMG recording.\nSignal Processing & Validation: Raw sEMG data will be processed offline. A 4th-order Butterworth bandpass filter (20-450 Hz) will be applied, followed by a 50/60 Hz notch filter to remove powerline interference. The signal will be segmented using a sliding window of 250 ms with a 50% overlap. For each window, the following features will be extracted per channel: Root Mean Square (RMS), Mean Absolute Value (MAV), Waveform Length (WL), and the first 4 autoregressive coefficients. This yields a 16-channel * 7-feature = 112-dimensional feature vector per window. A Support Vector Machine (SVM) with a radial basis function kernel will be used for classification. Performance will be evaluated using a leave-one-subject-out cross-validation scheme to assess generalizability. The primary metric is classification accuracy, calculated as the percentage of correctly classified windows. A physically realistic accuracy claim for this protocol on 7 gestures is 90-95%, acknowledging inherent physiological variability and signal noise. All processing will be performed in MATLAB or Python using validated toolboxes (e.g., BioSPPy, scikit-learn).\nSafety & Feasibility: Skin will be cleaned with alcohol wipes, and electrode-skin impedance verified to be <10 kΩ. A 2-minute rest is provided between blocks to minimize fatigue.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000260", "source_id": "50f2a1204559", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Tracking Using PPG and ECG.\n\nObjective:\n\nTo perform continuous blood pressure tracking using photoplethysmography and electrocardiography signals by extracting pulse wave features, ECG R-peaks, PTT, and PWV for blood pressure estimation.\n\nEquipment:\n\nPPG signals will be acquired using a MAX30102 sensor module with green, red, and infrared LEDs and a photodetector. The green LED wavelength is 525 nm, the red LED wavelength is 660 nm, and the infrared LED wavelength is 940 nm. PPG data will be sampled at 100 Hz with 16-bit resolution.\n\nSingle-lead ECG signals will be recorded using disposable Ag/AgCl electrodes and an AD8232 analog front end. ECG data will be sampled at 500 Hz with 24-bit resolution. Multi-lead ECG will also be recorded using a Biopac MP160 system at 1000 Hz to ensure accurate R-peak detection.\n\nReference blood pressure will be measured using a validated sphygmomanometer, Omron HEM-907. The system is powered by a single CR2032 coin cell.\n\nSensor Placement & Configuration:\n\nThe PPG sensor will be configured to acquire pulse wave signals using green, red, and infrared illumination. The single-lead ECG configuration will use disposable Ag/AgCl electrodes for R-peak detection. Multi-lead ECG will be recorded using the Biopac MP160 system for validation of ECG timing. PWV will be estimated using a fixed arterial path length measured from the ECG electrode to the PPG sensor.\n\nData Acquisition Procedure:\n\nContinuous PPG and ECG signals will be recorded simultaneously. Validation will involve 20 healthy volunteers during resting and mild exercise conditions. During calibration, simultaneous reference blood pressure measurements will be acquired using the Omron HEM-907 sphygmomanometer.\n\nContinuous blood pressure tracking will be performed by applying the calibrated model to real-time PTT values.\n\nSignal Processing & Validation:\n\nPPG signals will be bandpass filtered from 0.5 to 5 Hz using zero-phase Butterworth filters. ECG signals will be bandpass filtered from 0.05 to 150 Hz using zero-phase Butterworth filters.\n\nECG R-peaks will be detected using the Pan-Tompkins algorithm. PPG pulse peaks will be identified by local maxima. PTT will be calculated as the time interval between the ECG R-peak and the corresponding PPG pulse peak. PWV will be estimated using the fixed arterial path length measured from the ECG electrode to the PPG sensor.\n\nBlood pressure will be estimated using a linear regression model, BP = a × PTT + b, where coefficients a and b are determined during the calibration phase with simultaneous reference blood pressure measurements.\n\nValidation will compare estimated blood pressure with reference measurements. Performance metrics will include mean error, standard deviation of error, and Pearson correlation coefficient. The protocol achieved a mean error of -0.3 ± 4.2 mmHg for systolic blood pressure and 0.1 ± 3.8 mmHg for diastolic blood pressure, meeting the clinical accuracy standard of ±5 mmHg.\n\nSafety & Feasibility:\n\nMeasurements will be conducted during resting and mild exercise conditions. Reference blood pressure will be measured using the validated Omron HEM-907 sphygmomanometer. The setup uses PPG sampling at 100 Hz, single-lead ECG sampling at 500 Hz, multi-lead ECG sampling at 1000 Hz; 72 hours of continuous operation.", "three_class_category": "Physical / Hardware", "violated_constraint": "power_budget", "violated_principle": "Power budget infeasibility", "why_invalid": "The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: First, the user wants me to generate a detailed experimental protocol for continuous blood pressure tracking using PPG and ECG..", "minimal_fix": "Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000261", "source_id": "5857d65bd040", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nMotion data were captured using two IMU systems and validated against an optical motion capture system during standardized activity trials.\n\nObjective:\n\nThe objective is to acquire motion data for activity classification and joint-angle estimation, compare IMU-derived kinematic outputs against optical motion capture ground truth, and assess robustness using a secondary IMU system on a subset of trials.\n\nEquipment:\n\nThe primary system comprised four Xsens MTi-630 9-axis IMUs with an accelerometer range of ±160 m/s², accelerometer bandwidth of 0–10 Hz, gyroscope range of ±2000 dps, and magnetometer range of ±8 Gauss. The primary system sampled at 400 Hz via a synchronized Xsens MTi-600 Awinda station.\n\nThe secondary system used a Bosch BNO055 9-axis IMU with an accelerometer range of ±16g and gyroscope range of ±2000 dps, sampling at 100 Hz. Validation was performed using a 12-camera optical motion capture system, Qualisys Oqus, operating at 200 Hz. Signal processing was implemented in MATLAB 2023a.\n\nSensor Placement & Configuration:\n\nParticipants wore IMUs and reflective markers placed on anatomical landmarks. All IMU data were timestamped and transmitted wirelessly to a host PC. The primary Xsens IMU system was synchronized through the Xsens MTi-600 Awinda station, while the Bosch BNO055 system was used for validation on a subset of trials.\n\nData Acquisition Procedure:\n\nFifteen participants performed a standardized protocol consisting of walking, running, stair ascent, stair descent, and sitting-to-stand transitions while wearing the IMUs and reflective markers. Motion data were recorded using the primary IMU system, with the secondary IMU system used on a subset of trials. Optical motion capture data were collected concurrently as ground truth.\n\nSignal Processing & Validation:\n\nRaw accelerometer and gyroscope data were passed through a 4th-order Butterworth low-pass filter with a 50 Hz cutoff frequency to attenuate high-frequency noise. A complementary filter with a time constant of 0.5 seconds fused accelerometer and gyroscope data to estimate sensor orientation. From the estimated orientation and calibrated acceleration, the gravitational component was removed to obtain linear acceleration.\n\nKey kinematic features, including signal magnitude area, zero-crossing rate, and spectral entropy, were extracted from 2-second sliding windows with 50% overlap for activity classification. Joint angles derived from IMU orientations were compared with optical motion capture ground truth. Expected performance metrics include an RMSE of less than 5 degrees for sagittal-plane joint angles and classification accuracy exceeding 95% for the listed activities using a support vector machine trained on the extracted features.\n\nSafety & Feasibility:\n\nThe protocol involved non-invasive wearable IMU recording and optical motion capture during common movement tasks. Feasibility was assessed through wireless timestamped data transmission, comparison with optical motion capture ground truth, joint-angle RMSE, and activity-classification accuracy.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The accelerometer bandwidth of 0-10 Hz is insufficient to capture frequency components above 10 Hz, such as those in walking and running (which typically have content up to 20-30 Hz), resulting in loss of critical signal data and invalid kinematic measurements. Fix: Increase the accelerometer bandwidth to at least 50 Hz or higher to adequately cover the signal frequency content up to the low-pass filter cutoff.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000264", "source_id": "a0ece592e15f", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nMulti-Modal EEG Recording for Motor Imagery Classification\n\nObjective:\n\nAcquire EEG signals using wet gel, dry headband, and in-ear EEG sensors to evaluate cue-based motor imagery classification across separate and fused electrode modalities.\n\nEquipment:\n\nEEG signals will be acquired using three electrode types:\n\nA 64-channel wet gel EEG system, g.tec g.USBamp, g.tec medical engineering GmbH, Austria, arranged according to the international 10–20 system.\n\nA 16-channel dry EEG headband, Muse 2, InteraXon Inc., Canada.\n\nA 6-channel in-ear EEG sensor, Duo, Nao Medical, USA.\n\nAll systems will record with a sampling rate of 120 Hz, 24-bit analog-to-digital converter resolution, and a hardware bandpass filter of 0.5–100 Hz.\n\nSignal processing will be performed in MATLAB using the EEGLAB and BCILAB toolboxes.\n\nSensor Placement & Configuration:\n\nThe 64-channel wet gel electrodes will be arranged according to the international 10–20 system.\n\nThe 16-channel dry EEG headband and 6-channel in-ear EEG sensor will be used as additional electrode modalities.\n\nA common average reference will be applied offline.\n\nData Acquisition Procedure:\n\nParticipants will perform a cue-based motor imagery task following a standard Graz paradigm.\n\nThe task will include kinesthetic imagery of left hand, right hand, and feet movements, interleaved with a resting state.\n\nEach trial will last 8 seconds, including a 2-second cue, a 4-second imagery period, and a 2-second rest interval.\n\nTen blocks of 20 trials per condition will be recorded.\n\nSignal Processing & Validation:\n\nContinuous EEG will be bandpass filtered offline from 1 to 40 Hz using a 4th-order zero-phase Butterworth filter.\n\nIndependent Component Analysis will be used to identify and remove components corresponding to eye blinks and muscle artifacts.\n\nFor feature extraction, the filter bank common spatial pattern algorithm will be applied to the mu band, 8–12 Hz, and beta band, 13–30 Hz.\n\nThe logarithmic variance of the resulting spatial filters will serve as features.\n\nA Linear Discriminant Analysis classifier will be trained on features from each electrode modality separately and in a fused feature space.\n\nA 10×10-fold cross-validation scheme will be used to evaluate classification performance. Expected performance metrics include classification accuracy, with target accuracy >70% for dry and ear-EEG and >85% for wet EEG, Cohen’s kappa coefficient, and information transfer rate.\n\nStatistical significance between modality performances will be assessed using repeated-measures ANOVA with post-hoc Tukey HSD tests.\n\nSafety & Feasibility:\n\nThe protocol uses non-invasive EEG acquisition with wet gel, dry headband, and in-ear EEG sensors during cue-based motor imagery and resting-state trials. Offline common average referencing, artifact removal, cross-validation, and statistical testing will be used to evaluate modality-specific and fused classification performance.", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. The hardware bandpass filter limits the signal to a maximum frequency of 100 Hz, requiring a sampling rate of at least 200 Hz to avoid aliasing. With a sampling rate of 120 Hz, which is below 200 Hz, the experiment violates the theorem, making the recorded data physically invalid due to undersampling. Fix: Increase the sampling rate to at least 200 Hz, such as reverting to the original 256 Hz.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000267", "source_id": "a53c5bb3881e", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG-Based Motor Imagery and P300 Classification Using Wet Gel, Dry, and Ear-EEG Systems\n\nObjective:\n\nAcquire EEG data using wet gel, dry electrode, and ear-EEG systems to evaluate three-class motor imagery classification and binary P300 detection.\n\nEquipment:\n\nEEG data will be acquired using three electrode systems:\n\nA 64-channel wet gel system, Brain Products actiCHamp Plus, with 16-bit ADC resolution, 512 Hz sampling rate, and a 0.1–100 Hz hardware bandpass filter.\n\nA 16-channel dry electrode system, g.tec g.SCARABEO, with 24-bit ADC resolution and 64 Hz sampling rate.\n\nA custom ear-EEG array with 12 electrodes placed in-ear and around-the-ear.\n\nAll systems will record with a common average reference.\n\nOffline analysis will be performed in MATLAB and EEGLAB.\n\nSensor Placement & Configuration:\n\nThe 64-channel wet gel system will be arranged according to the international 10–20 system.\n\nMotor imagery feature extraction will focus on motor cortex electrodes C3, Cz, and C4.\n\nThe custom ear-EEG array will include 12 electrodes placed in-ear and around-the-ear.\n\nData Acquisition Procedure:\n\nThe experimental paradigm will comprise 200 trials of motor imagery involving left hand, right hand, and feet imagery, cued by visual prompts.\n\nEach trial will include a 4-second imagery window and a 3-second inter-trial rest.\n\nFor P300-based protocols, single-trial event-related potentials will be extracted from a secondary target/non-target oddball task.\n\nSignal Processing & Validation:\n\nContinuous data will be bandpass filtered from 1 to 40 Hz using a 4th-order Butterworth filter and notch-filtered at 50 Hz.\n\nIndependent Component Analysis will be used to remove ocular and muscular artifacts.\n\nFor each motor imagery trial, the 4-second imagery window will be extracted.\n\nFeature extraction will target mu-band power from 8 to 12 Hz and beta-band power from 13 to 30 Hz from motor cortex electrodes C3, Cz, and C4 using bandpower spectral density estimation.\n\nCommon Spatial Patterns will be applied to optimize discriminability between classes.\n\nA 10×10-fold cross-validated Linear Discriminant Analysis classifier will be used for motor imagery classification, and stepwise linear discriminant analysis will be used for P300 detection.\n\nValidation metrics will include classification accuracy, Cohen’s kappa, and Information Transfer Rate. Expected performance is ≥70% accuracy for 3-class motor imagery and ≥80% for binary P300 detection, with an ITR of ≥15 bits/min.\n\nSafety & Feasibility:\n\nThe protocol uses non-invasive EEG acquisition with wet gel, dry electrode, and ear-EEG systems during visually cued motor imagery and a secondary target/non-target oddball task. Common average referencing, artifact removal, cross-validation, and standard BCI performance metrics will be used to evaluate system performance.", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The sampling rate of 64 Hz results in a Nyquist frequency of 32 Hz, which is less than the maximum signal frequency of 40 Hz from the bandpass filter, causing aliasing and invalidating data for frequencies above 32 Hz. Fix: Increase the sampling rate of the g.tec system to at least 80 Hz, such as setting it to 256 Hz.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000277", "source_id": "15e9d586cb3d", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol:\n\nSilent Speech Recognition Using a Contact Microphone and IMU\n\nObjective:\n\nAcquire subvocalization vibration and laryngeal movement signals from healthy adult participants to perform silent speech recognition on a 100-word vocabulary.\n\nEquipment:\n\nData will be collected from healthy adult participants seated in a quiet room.\n\nA MEMS contact microphone, Knowles SPH0645LM4H, with a frequency response of 50–500 Hz and 16-bit resolution, will be used to capture subvocalization vibrations.\n\nA 9-axis inertial measurement unit, Bosch BMX055, with 16-bit resolution for the accelerometer, gyroscope, and magnetometer, will be used to track laryngeal movement.\n\nAudio signals will be sampled at 16 kHz with a 24-bit analog-to-digital converter, National Instruments NI-9234. IMU data will be sampled at 100 Hz via an I2C interface.\n\nSensor Placement & Configuration:\n\nThe MEMS contact microphone will be affixed to the thyroid cartilage using medical adhesive.\n\nThe 9-axis IMU will be mounted adjacent to the microphone to track laryngeal movement.\n\nData Acquisition Procedure:\n\nParticipants will be seated in a quiet room during data collection.\n\nSilent speech data will be collected from 20 participants using a vocabulary of 100 words, with 10 repetitions per word.\n\nAudio and IMU data will be acquired simultaneously during silent speech production.\n\nSignal Processing & Validation:\n\nA 4th-order Butterworth bandpass filter from 80 to 4000 Hz will be applied to the microphone signal to isolate speech-related vibrations.\n\nIMU data will be low-pass filtered at 20 Hz to remove high-frequency noise.\n\nFeature extraction will compute 13 Mel-frequency cepstral coefficients and their deltas from the audio stream.\n\nQuaternion-based orientation and angular velocity features will be derived from the IMU.\n\nA hidden Markov model with Gaussian mixture models will be trained for silent speech recognition on the 100-word vocabulary.\n\nValidation will use a leave-one-subject-out cross-validation scheme. Performance will be evaluated using word error rate and accuracy.\n\nExpected metrics include a WER below 15% and accuracy exceeding 85% for isolated word recognition.\n\nSafety & Feasibility:\n\nThe protocol uses a contact microphone attached to the thyroid cartilage with medical adhesive and an adjacent IMU for laryngeal movement tracking. Data will be collected from seated healthy adult participants in a quiet room.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The microphone has a bandwidth of 50-500 Hz, but the bandpass filter requires frequencies up to 4000 Hz to isolate speech-related vibrations, so frequencies above 500 Hz cannot be captured, making the experiment physically impossible. Fix: Use a microphone with a frequency response that covers at least up to 4000 Hz, such as the original 50-8000 Hz specification.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000282", "source_id": "41543f72923a", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nWearable IMU-Based Daily Activity Recognition\n\nObjective:\n\nCollect motion data from ten healthy adult participants performing daily activities, process inertial signals from five wireless IMU nodes, and classify sitting, standing, walking, and stair climbing.\n\nEquipment:\n\nMotion data will be collected from ten healthy adult participants aged 25 ± 3 years.\n\nEach participant will be instrumented with five wireless IMU nodes, Xsens DOT, Xsens Technologies B.V.\n\nEach node will contain a 6-axis IMU, including an accelerometer with ±16 g range and a gyroscope with ±2000 dps range, and a 3-axis magnetometer with ±800 µT range.\n\nData will be streamed via Bluetooth Low Energy to a host computer at a sampling rate of 200 Hz for all sensors, providing a Nyquist frequency of 100 Hz.\n\nSignal processing will be performed in MATLAB R2023b.\n\nSensor Placement & Configuration:\n\nFive wireless IMU nodes will be placed bilaterally on the wrists and ankles, and over the L3 vertebra.\n\nA static calibration procedure will be performed at the start of each session to determine and correct individual sensor mounting misalignment and offset errors.\n\nFor orientation estimation, a complementary filter will fuse gyroscope and accelerometer data with a time constant of 0.5 seconds. Magnetometer data will be used for yaw correction in a Madgwick filter during stationary periods to mitigate gyroscopic drift.\n\nData Acquisition Procedure:\n\nParticipants will perform a standardized set of daily activities, including sitting, standing, walking, and stair climbing.\n\nSensor data will be recorded from all five IMU nodes at 200 Hz and streamed to a host computer via Bluetooth Low Energy.\n\nThe sampling configuration will provide a Nyquist frequency of 100 Hz, above the 0–20 Hz band of interest for human motion.\n\nSignal Processing & Validation:\n\nRaw sensor data will be processed in MATLAB R2023b.\n\nA 4th-order Butterworth low-pass filter with a 20 Hz cutoff will be applied to accelerometer and gyroscope signals to remove high-frequency noise and vibration.\n\nActivity recognition will use a 2-second sliding window with 50% overlap.\n\nTime-domain features, including mean, variance, and signal magnitude area, and frequency-domain features, including spectral energy and dominant frequency, will be extracted from each window.\n\nA Random Forest classifier with 100 trees will be trained on data from seven participants and validated on the remaining three.\n\nExpected performance, based on prior literature, is classification accuracy exceeding 95% for the defined activity set, with inter-session reliability, measured by Intraclass Correlation Coefficient, greater than 0.90 for peak angular velocity and stride time parameters derived from the processed signals.\n\nSafety & Feasibility:\n\nThe protocol uses wearable wireless IMU nodes placed on the wrists, ankles, and L3 vertebra during standardized daily activities. Data will be streamed via Bluetooth Low Energy. Environmental Operating Range: -40°C to +85°C.", "three_class_category": "Physical / Hardware", "violated_constraint": "temperature_range", "violated_principle": "Operating temperature violation", "why_invalid": "The protocol requires the electronics to operate outside their rated temperature range. Under those conditions, sensor accuracy, oscillator stability, battery behavior, and circuit reliability cannot be assumed. In this sample, the problematic modification is: Motion data were collected from ten healthy adult participants (age: 25 ± 3 years) performing a standardized set of daily activities (sitting, standing, walking, stair climbing)..", "minimal_fix": "Restrict the experiment to the rated component temperature range or use components rated and validated for the claimed environment.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000296", "source_id": "d3a9a880386f", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "valid", "protocol": "Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit (IMU)\n\nObjective: To develop a silent speech interface by capturing subvocalization-induced laryngeal vibrations and associated neck movements using a contact microphone and IMU, enabling the classification of a predefined vocabulary of 100 words.\n\nEquipment: \n- Throat Microphone: MEMS contact microphone (e.g., Knowles SPH0645LM4H-B). Frequency response: 50 Hz – 10 kHz. Mounted in a flexible, medical-grade silicone housing.\n- IMU: 9-axis (3-axis accelerometer ±16g, gyroscope ±2000 dps, magnetometer ±4900 µT) module (e.g., BNO055).\n- Data Acquisition: A microcontroller (e.g., Arduino Nano 33 BLE) synchronizes and streams data. Microphone sampling rate: 16,000 Hz (16-bit). IMU sampling rate: 100 Hz.\n\nSensor Placement & Configuration: The microphone is secured over the participant’s thyroid cartilage (Adam's apple) using a gentle, adjustable neck band. The IMU is affixed directly adjacent to the microphone housing to track laryngeal elevation/depression and rotation.\n\nData Acquisition Procedure: Calibration (5 min): Participant performs maximal laryngeal elevation/depression and head turns for IMU sensor fusion calibration. Ambient noise is recorded for 10 seconds for noise profile estimation. Data Collection (30 min per session): Participant silently articulates (subvocalizes) words from the target vocabulary. Each word is prompted visually on a screen. Each prompt is held for 3 seconds, with a 2-second rest between trials. Each word is repeated 10 times. A resting state (no movement, no subvocalization) is recorded between sets for baseline.\n\nSignal Processing & Validation: Preprocessing: Microphone signal is bandpass filtered (80–4000 Hz) and normalized. IMU data undergoes low-pass filtering (cutoff 10 Hz) to isolate laryngeal movement from gross head motion. Feature Extraction: Time-domain (RMS, zero-crossing rate), frequency-domain (spectral centroid, band energy), and IMU features (orientation quaternion derivatives, acceleration peaks) are extracted from 500 ms windows. Validation: A 10-fold cross-validation scheme is used. A classifier (e.g., Support Vector Machine or 1D-CNN) is trained on data from 8 participants and tested on 2 held-out participants to evaluate generalization. Performance is measured by word classification accuracy, with a target of >90% for the closed-set vocabulary.\n\nSafety & Feasibility: The protocol uses non-invasive, wearable sensors with no known risks. The sampling rates are sufficient to capture the target physiological signals without aliasing. The experimental design controls for motion artifacts and includes inter-session rest to prevent muscle fatigue.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000302", "source_id": "212e01d08e0b", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nSurface Electromyography (sEMG) Recording and Hand Gesture Classification Using Multiple Electrode Types\n\nObjective:\n\nAcquire sEMG signals from the dominant forearm during 10 distinct hand gestures and compare classification performance across three electrode types: wet gel, dry, and high-density arrays.\n\nEquipment:\n\nWet Gel Electrodes: Kendall™ 100 series (Covidien), bipolar configuration.\n\nDry Electrodes: Delsys Inc., Natick, MA.\n\nHigh-Density Array: TMSi, 16-channel dry electrode array (Oldenzaal, Netherlands).\n\nAcquisition System: Delsys Trigno™ Avanti, 24-bit ADC, hardware bandpass 20–450 Hz.\n\nFiltering: Digital 50 Hz notch filter for power-line interference.\n\nSoftware: MATLAB for segmentation, feature extraction, and classifier training.\n\nSensor Placement & Configuration:\n\nWet and dry electrodes placed over the target forearm muscles in a bipolar configuration.\n\nHigh-density array positioned to cover the forearm with 16 channels.\n\nCommon reference electrode placed on the olecranon.\n\nWet electrodes applied after skin preparation with abrasive paste (Nuprep®) and alcohol.\n\nData Acquisition Procedure:\n\nParticipants: 15 healthy adults (8 male, 7 female; age 25±3 years).\n\nSubjects performed 10 hand gestures, each repeated as per protocol guidance.\n\nSignals sampled at 800 Hz and monitored for motion artifacts and saturation.\n\nTrials repeated if signal-to-noise ratio fell below 10 dB.\n\nRaw sEMG segmented into 200 ms windows with 50 ms overlap.\n\nSignal Processing & Validation:\n\nTime-domain features: Root Mean Square (RMS), Waveform Length, Zero Crossings.\n\nFrequency-domain feature: Mean Power Frequency.\n\nLinear Discriminant Analysis (LDA) classifier trained and validated using 10-fold cross-validation for each electrode configuration.\n\nPerformance metrics: overall accuracy, F1-score, and confusion matrices.\n\nStatistical analysis: repeated-measures ANOVA (α=0.05).\n\nHypothesized accuracies: high-density array >95%, wet gel 92±3%, dry electrodes 88±5%.\n\nSafety & Feasibility:\n\nNon-invasive surface electrodes used.\n\nSkin preparation and monitoring prevent electrode irritation and ensure signal quality.\n\nReal-time monitoring ensures artifact-free data acquisition.\n\nProtocol supports reliable evaluation of multiple electrode configurations in gesture classification.", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The bandpass filter limits the signal to a maximum frequency of 450 Hz, requiring a sampling rate of at least 900 Hz (2 * 450 Hz). The sampling rate of 800 Hz is below this threshold, leading to aliasing and invalidating frequency-domain features like Mean Power Frequency. Fix: Increase the sampling rate to at least 900 Hz, such as 1000 Hz or 2000 Hz.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000317", "source_id": "91be97494458", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol:\n\nSubvocalized speech signals were recorded using a wearable device integrating a MEMS contact microphone and a 9-axis IMU, with audio and motion features fused for word-level classification.\n\nObjective:\n\nThe objective is to recognize silent speech from a 100-word vocabulary by combining audio features from a contact microphone and motion features from an IMU, evaluating classification accuracy and latency.\n\nEquipment:\n\nThe custom wearable device integrated a Knowles SPU0410LR5H-QB MEMS contact microphone (50 Hz–2 kHz bandwidth, 65 dB SNR) and a Bosch BNO055 9-axis IMU (accelerometer ±16 g, gyroscope ±2000°/s). Data were acquired via a custom PCB with an STM32H7 microcontroller, sampling the microphone at 16,000 Hz (24-bit) and the IMU at 100 Hz. Signal processing was implemented in Python using NumPy and SciPy.\n\nSensor Placement & Configuration:\n\nThe contact microphone was positioned over the thyroid cartilage using medical-grade adhesive to maintain consistent contact. The IMU was integrated into the wearable module adjacent to the microphone to capture laryngeal motion.\n\nData Acquisition Procedure:\n\nTen participants (5 male, 5 female) performed 10 repetitions of each word in the 100-word vocabulary under silent articulation conditions. Audio and IMU data were recorded simultaneously for each repetition.\n\nSignal Processing & Validation:\n\nAudio signals were bandpass filtered at 80–4,000 Hz (4th-order Butterworth), segmented into 25 ms frames with 10 ms overlap, and 13 MFCCs were extracted per frame. IMU signals were processed with a complementary filter for orientation estimation, and features including angular velocity and linear acceleration were extracted from 500 ms windows. Audio and IMU features were concatenated per utterance.\n\nA 1D Convolutional Neural Network with three convolutional layers was trained using 8-fold cross-subject validation. Expected performance metrics are >85% classification accuracy and F1-score >0.83, with recognition latency under 300 ms.\n\nSafety & Feasibility:\n\nThe protocol involved non-invasive wearable recording with secure microphone and IMU placement over the thyroid cartilage. Power consumption was measured at 150 mW during continuous operation, ensuring safe and practical real-time acquisition for subvocal speech recognition.", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The microphone bandwidth (50 Hz - 2 kHz) does not cover the upper frequency limit of the bandpass filter (4000 Hz), so frequencies above 2 kHz are not captured, leading to incomplete audio features and invalid MFCC extraction for speech signals. Fix: Use a microphone with a bandwidth that extends to at least 4000 Hz.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000325", "source_id": "50f2a1204559", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous blood pressure was estimated non-invasively using pulse transit time derived from synchronized ECG and PPG signals, with beat-to-beat BP compared against invasive arterial measurements during rest and mild exercise.\n\nObjective:\n\nThe objective is to continuously monitor systolic and diastolic blood pressure non-invasively using PTT, and to validate accuracy against invasive radial artery measurements according to ISO 81060-2 standards.\n\nEquipment:\n\nECG signals were recorded using a Biopac MP160 system with a single-lead ECG100C module, sampled at 1000 Hz, 0.05–150 Hz bandwidth, 24-bit resolution. PPG signals were acquired from the left index finger using a custom reflectance sensor with green (525 nm), red (660 nm), and infrared (940 nm) LEDs (Thorlabs LEDD1B driver) and an OPT101 photodiode, bandpass filtered (0.5–5 Hz, 4th-order Butterworth) and digitized at 100 Hz using an NI USB-6211 DAQ with 16-bit resolution. Reference BP was measured continuously via radial artery catheter (TruWave, Edwards Lifesciences) connected to a Vigilance II monitor. The system is powered by a single ML2032 coin cell serving as a battery.\n\nSensor Placement & Configuration:\n\nThe ECG module was attached according to single-lead placement standards, and the PPG sensor was placed on the left index finger. Participants were seated comfortably. Reference arterial line measurements were collected using standard radial catheterization procedures.\n\nData Acquisition Procedure:\n\nData were collected from participants during a 5-minute baseline period followed by 30 minutes of rest and mild exercise (leg raises). ECG, PPG, and invasive arterial BP signals were recorded simultaneously and synchronized via the acquisition system.\n\nSignal Processing & Validation:\n\nECG R-peaks were detected using the Pan-Tompkins algorithm. PPG pulse foot detection used a second-derivative maximum method on the infrared channel. PTT was calculated as the interval between ECG R-peak and PPG foot. A subject-specific linear regression model (BP = a * PTT + b) was calibrated during the 5-minute baseline. Continuous beat-to-beat BP estimates were computed for the remaining 30 minutes. Performance was evaluated against the invasive reference using mean absolute error (MAE), standard deviation of error (SDE), and Pearson correlation coefficient (r). Target metrics were MAE ≤ 5 mmHg and SDE ≤ 8 mmHg.\n\nSafety & Feasibility:\n\nThe protocol employed non-invasive PPG and single-lead ECG recordings alongside standard arterial line measurements. Participants were seated and monitored for safety during mild exercise. The system’s power and acquisition design support safe, continuous 72-hour operation while providing clinically validated non-invasive BP measurements.", "three_class_category": "Physical / Hardware", "violated_constraint": "power_budget", "violated_principle": "Power budget infeasibility", "why_invalid": "The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: Continuous blood pressure (BP) was estimated non-invasively using pulse transit time (PTT), derived from synchronized electrocardiography (ECG) and photoplethysmography (PPG) signals..", "minimal_fix": "Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000330", "source_id": "94af7bc3db78", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nMotion data were recorded using a wearable sensor node integrating a 6-axis IMU and a 9-axis IMU. The data were processed to estimate segment orientation, compensate for gravity, and classify common daily activities, with validation against an optical motion capture system.\n\nObjective:\n\nThe objective is to accurately measure body segment orientations and classify activities such as walking, sitting, and stair ascent/descent using IMU data, and to validate performance against optical motion capture ground truth.\n\nEquipment:\n\nThe wearable node included a Bosch BMI270 6-axis IMU (±16 g, ±2000 dps) and a Bosch BNO055 9-axis IMU (±16 g, ±2000 dps, ±2500 µT magnetometer). Both IMUs were configured with a 200 Hz sampling rate and 16-bit resolution. Raw data were streamed via Bluetooth Low Energy to a host PC. Validation was performed with a 12-camera Qualisys optical motion capture system operating at 100 Hz. All processing was performed in MATLAB R2023b.\n\nSensor Placement & Configuration:\n\nIMUs were mounted on the wearable sensor housing, which was affixed to the participant’s body segments. For validation, a rigid cluster of four reflective markers was attached to the IMU housing. The 9-axis IMU used its onboard Kalman filter to provide quaternion-based orientation, fusing accelerometer, gyroscope, and magnetometer data.\n\nData Acquisition Procedure:\n\nFifteen participants performed ten common activities, including walking, sitting, and stair ascent/descent. IMU data were recorded continuously at 200 Hz while optical motion capture provided ground truth. Each session began with a 30-second static calibration to determine sensor-specific bias offsets.\n\nSignal Processing & Validation:\n\nAccelerometer and gyroscope signals were low-pass filtered (4th-order Butterworth, 80 Hz cutoff) for anti-aliasing. Quaternion-based orientation estimates from the 9-axis IMU were used to transform body-frame accelerations into a global frame for gravity compensation and step counting. Features were extracted from time- and frequency-domain signals and fed to a random forest classifier. Orientation RMSE against optical motion capture was expected to be <3° for dynamic motions. Activity recognition accuracy, evaluated via 5-fold cross-validation, was expected to exceed 95%. The system achieved 99.99% classification accuracy with zero calibration.\n\nSafety & Feasibility:\n\nThe protocol involved non-invasive IMU placement and optical tracking. Sensor calibration, gravity compensation, and synchronized acquisition ensured accurate orientation and activity estimation. The setup is safe, feasible, and reproducible for capturing full-body motion in daily activities.", "three_class_category": "Physical / Hardware", "violated_constraint": "accuracy_impossibility", "violated_principle": "Unrealistic performance claim", "why_invalid": "The stated performance exceeds the physical and statistical limits of the sensing modality. Sensor noise, calibration uncertainty, physiological variability, and reference-device error prevent the claimed precision. In this sample, the problematic modification is: Data were collected using a custom wearable sensor node integrating a 6-axis IMU (Bosch BMI270, ±16g/±2000 dps) and a 9-axis IMU (Bosch BNO055, ±16g/±2000 dps, ±2500 µT magnetometer)..", "minimal_fix": "Replace the unrealistic accuracy claim with a physically plausible performance target and include calibration, uncertainty, and reference-device error in validation.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000338", "source_id": "8ac99e5395b7", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous blood pressure was tracked non-invasively using synchronized photoplethysmography and electrocardiography, with beat-to-beat BP estimated from pulse transit time and validated against a non-invasive reference device.\n\nObjective:\n\nThe objective is to continuously estimate systolic and diastolic blood pressure using PTT derived from ECG and PPG signals, and to validate accuracy and reliability against a Finapres NOVA reference system according to ISO 81060-2:2018 standards.\n\nEquipment:\n\nA Biopac MP160 data acquisition system was used with an ECG100C module for single-lead ECG (Lead II configuration, 1000 Hz sampling, 0.5–150 Hz bandwidth, 16-bit resolution) and a PPG100C module for reflective PPG (green LED, 530 nm, 500 Hz sampling, 0.05–15 Hz bandwidth). Disposable Ag/AgCl electrodes (Kendall, Covidien) and a finger-clip PPG sensor (MPR-SS, Biopac) were employed. The Finapres NOVA system provided contralateral continuous reference BP. Signal processing was performed offline in MATLAB.\n\nSensor Placement & Configuration:\n\nECG electrodes were applied according to Lead II configuration on the chest. The PPG sensor was positioned on the index finger over a thin layer of opaque medical adhesive tape for secure attachment during movement. Reference Finapres cuff was placed on the contralateral hand. All sensors were synchronized for accurate PTT measurement.\n\nData Acquisition Procedure:\n\nParticipants were instrumented with ECG and PPG sensors and the Finapres cuff. A 10-minute recording session was conducted during which participants remained seated and at rest. ECG and PPG signals were recorded simultaneously at the specified sampling rates for subsequent PTT-based BP estimation.\n\nSignal Processing & Validation:\n\nECG signals were bandpass filtered (0.5–40 Hz) and R-peaks detected using the Pan-Tompkins algorithm. PPG signals were detrended, bandpass filtered (0.5–8 Hz), and pulse onset identified via the second derivative. Pulse Transit Time was calculated as the interval from ECG R-peak to PPG foot. A subject-specific linear model (PTT = a * ln(BP) + b) was calibrated using three simultaneous oscillometric measurements. Beat-to-beat BP was estimated continuously and validated against the Finapres reference using mean absolute error, Pearson’s correlation coefficient, and Bland-Altman analysis. The target performance was MAE ≤ 5 mmHg and standard deviation ≤ 8 mmHg.\n\nSafety & Feasibility:\n\nThe protocol involved non-invasive, wearable sensors with secure attachment and contralateral reference BP monitoring. The setup allows safe and continuous 10-minute BP tracking while adhering to clinical standards for non-invasive BP measurement.", "three_class_category": "Perception & Anatomy", "violated_constraint": "optical_obstruction", "violated_principle": "Optical signal-path obstruction", "why_invalid": "optical_obstruction: PPG relies on light transmission/reflection; opaque obstacles block optical path. The opaque tape blocks the 530 nm green LED light from the PPG sensor, preventing light penetration and reflection from the skin, which is essential for PPG signal acquisition. This makes it physically impossible to obtain valid PPG data, as no optical path exists for the light to interact with blood volume changes. Fix: Remove the opaque tape and ensure the PPG sensor has direct skin contact without any obstructions.", "minimal_fix": "Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000342", "source_id": "914dd67962a0", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG data were recorded using a hybrid 16-channel system combining wet gel, dry, and ear-EEG electrodes for motor imagery and P300 speller tasks. Data were processed to extract CSP and ERP features for classification and evaluated using cross-validation.\n\nObjective:\n\nThe objective is to classify motor imagery (left vs. right hand) and detect P300 responses using a hybrid EEG setup, assessing classification accuracy and information transfer rate for both offline analyses.\n\nEquipment:\n\nEEG acquisition employed a 16-channel g.tec g.USBamp biosignal amplifier (24-bit ADC, 512 Hz sampling). Wet gel electrodes (g.LADYbird, 8 channels) were positioned over motor cortex sites (C3, Cz, C4, FC3, FC1, FCz, FC2, FC4). Dry electrodes (g.SCARABEO, 4 channels) were positioned over prefrontal and parietal regions. Two cEEGrid ear-EEG electrodes (TMSi) were placed in the left ear for reference and artifact monitoring. Hardware bandpass filtering was 0.1–100 Hz with a 50 Hz notch filter. Signal processing used MATLAB with EEGLAB and BCILAB.\n\nSensor Placement & Configuration:\n\nWet gel electrodes targeted central motor areas for motor imagery. Dry electrodes covered prefrontal and parietal regions. Ear-EEG electrodes provided bilateral reference and artifact monitoring. All channels were re-referenced to the average of the ear electrodes.\n\nData Acquisition Procedure:\n\nParticipants performed a motor imagery task (left hand vs. right hand) with 4-second trials and a separate P300 speller task with visual stimuli. EEG signals were recorded continuously from all 16 channels during the tasks.\n\nSignal Processing & Validation:\n\nEEG was bandpass filtered (1–45 Hz) for motor imagery and (1–12 Hz) for P300 extraction. ICA using the AMICA algorithm removed ocular and muscular artifacts. CSP features were computed on the 8-channel motor cortex mu/beta band (8–30 Hz) epochs; the first and last two features were used for shrinkage LDA classification. P300 epochs (0–600 ms post-stimulus) were downsampled to 25 Hz and classified using stepwise LDA. Validation employed a 5x5-fold nested cross-validation scheme. Performance metrics included classification accuracy and information transfer rate. Expected offline accuracy for 2-class motor imagery was 75–85% with ITR of 10–15 bits/min.\n\nSafety & Feasibility:\n\nThe protocol used non-invasive wet gel, dry, and ear-EEG electrodes with standard clinical placement. Artifact rejection and referencing ensured data quality. The setup is feasible for safe, repeatable hybrid EEG recordings in controlled laboratory conditions.", "three_class_category": "Signal & Sampling", "violated_constraint": "snr_floor", "violated_principle": "Signal-to-noise floor violation", "why_invalid": "The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data were acquired using a 16-channel g.tec g.USBamp biosignal (g.tec Medical Engineering, Austria) with 24-bit ADC resolution, sampling at 512 Hz..", "minimal_fix": "Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000354", "source_id": "50172d3ff07d", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture and Activity Recognition\nObjective: To acquire and process inertial data from wearable IMUs for the classification of daily living activities.\nEquipment: Two wireless 9-axis IMU units (e.g., Xsens MTw or equivalent). Each unit contains a tri-axial accelerometer (range: ±16g), gyroscope (range: ±2000 dps), and magnetometer. A central receiver unit for real-time data acquisition. A healthy adult volunteer (age 20-40). A synchronized video camera for activity labeling.\nSensor Placement & Configuration: Affix one IMU to the subject's lower back (L3 vertebra) using a secure elastic belt. Attach a second IMU to the dominant wrist. Initialize the system, setting the sampling rate to 200 Hz for all sensors (accelerometer, gyroscope, magnetometer) to adequately capture human motion dynamics up to 100 Hz without aliasing.\nData Acquisition Procedure: Perform a static calibration (5 seconds, subject standing still) to establish initial orientation and sensor biases. Conduct a dynamic calibration for the magnetometer by having the subject perform slow figure-eight motions. Instruct the subject to perform a pre-defined sequence of activities for 60 seconds each: walking, sitting, standing, stair ascent, and stair descent. Ensure a 10-second transition period between activities. Record synchronized video and IMU data throughout.\nSignal Processing & Validation: Apply a 4th-order Butterworth low-pass filter with a 20 Hz cutoff to raw accelerometer and gyroscope signals to remove high-frequency noise. Fuse accelerometer, gyroscope, and magnetometer data using a Madgwick or Mahony complementary filter to estimate sensor orientation (quaternions). From 5-second sliding windows (50% overlap), extract time- and frequency-domain features: mean, variance, root mean square, signal magnitude area, dominant frequency, and spectral entropy from the filtered acceleration and angular velocity signals. Use the synchronized video to manually label activity segments. Partition the dataset into 70% training and 30% testing. Train a supervised classifier (e.g., Random Forest) on the training features. Evaluate performance on the test set using accuracy, precision, recall, and a confusion matrix.\nSafety & Feasibility: Ensure subject comfort and secure sensor attachment to prevent motion artifacts. The chosen parameters (200 Hz, ±16g, ±2000 dps) are standard for human motion capture, preventing signal saturation during vigorous activities. The protocol is feasible with commercially available hardware and standard processing tools (e.g., MATLAB, Python).", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000357", "source_id": "50f2a1204559", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Tracking Using PPG and ECG.\n\nObjective:\n\nTo estimate continuous blood pressure using synchronized photoplethysmography and electrocardiography signals by extracting pulse wave features, ECG R-peaks, PTT, and PWV.\n\nEquipment:\n\nPPG signals will be captured with a custom sensor array incorporating green, red, and infrared LEDs, driven by a MAX86150 analog front end. The green LED wavelength is 530 nm, the red LED wavelength is 660 nm, and the infrared LED wavelength is 880 nm. PPG will be sampled at 100 Hz with 16-bit resolution and a 0.5–10 Hz bandwidth.\n\nECG data will be acquired using a single-lead AD8232 module at 500 Hz with 24-bit resolution and a 0.05–150 Hz bandwidth. A 12-lead ECG system, Biopac ECG100C, will provide reference R-peak detection. Reference blood pressure will be measured using a validated oscillometric sphygmomanometer, Omron HEM-907. The system is powered by a single CR2032 coin cell for continuous operation.\n\nSensor Placement & Configuration:\n\nThe PPG sensor will be configured to acquire pulse wave signals using green, red, and infrared LEDs. The single-lead ECG module will be configured for ECG R-peak detection. The 12-lead Biopac ECG100C system will serve as the multi-lead ECG setup for reference R-peak detection and validation of single-lead ECG timing.\n\nPTT will be calculated as the time delay between the ECG R-peak and the PPG foot point. PWV will be derived from PTT when the corresponding path length is available.\n\nData Acquisition Procedure:\n\nContinuous blood pressure tracking will be performed using synchronized PPG and ECG recordings. Validation will involve concurrent recordings with the Omron HEM-907 sphygmomanometer during a 30-minute protocol including rest and mild exercise.\n\nBaseline cuff measurements will be used for subject-specific calibration of the blood pressure estimation model. The multi-lead ECG will provide reference R-peak timing to validate single-lead ECG accuracy.\n\nSignal Processing & Validation:\n\nRaw PPG and ECG signals will be filtered using a 4th-order Butterworth bandpass filter to remove noise. ECG R-peaks will be detected using the Pan-Tompkins algorithm. PPG pulse waves will be segmented by identifying the foot point using the second derivative method.\n\nPTT will be calculated as the time delay between the ECG R-peak and the PPG foot point. Blood pressure will be estimated using a linear regression model calibrated per subject with baseline cuff measurements.\n\nValidation will compare estimated blood pressure against reference systolic and diastolic pressures. Performance will be assessed by computing the mean error and standard deviation against reference measurements, targeting an accuracy within ±5 mmHg as per clinical standards.\n\nSafety & Feasibility:\n\nThe protocol includes rest and mild exercise conditions during a 30-minute recording session. Reference blood pressure will be measured using the validated Omron HEM-907 sphygmomanometer. The setup uses synchronized PPG and ECG recordings, PPG sampling at 100 Hz, ECG sampling at 500 Hz, 12-lead ECG reference timing, and the continuous operation lasts for 3-days.", "three_class_category": "Physical / Hardware", "violated_constraint": "power_budget", "violated_principle": "Power budget infeasibility", "why_invalid": "The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: First, the user wants a detailed experimental protocol for continuous blood pressure tracking using PPG and ECG..", "minimal_fix": "Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000358", "source_id": "85892f2adcf9", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nFMCW Radar-Based Vital Sign Monitoring\n\nObjective:\n\nTo non-invasively measure respiration rate (RR) and heart rate (HR) using three frequency-modulated continuous-wave (FMCW) radar modules at 24, 60, and 77 GHz, and to validate the measurements against clinical reference devices.\n\nEquipment:\n\n24 GHz radar: Infineon BGT24MTR12, 500 MHz bandwidth, range resolution 30 cm\n\n60 GHz radar: Texas Instruments IWR6843ISK-ODS, 4 GHz bandwidth, range resolution 3.75 cm\n\n77 GHz radar: Texas Instruments AWR1843BOOST, 4 GHz bandwidth, range resolution 3.75 cm\n\nData acquisition system sampling IF at 5 kSPS\n\nPiezoelectric respiratory belt (ADInstruments MLT1132) for RR reference\n\n3-lead ECG module (ADInstruments ML132) for HR reference\n\nStable tripods for radar mounting\n\nHost PC for data capture and processing\n\nSensor Placement & Configuration:\n\nRadars mounted on stable tripods 1.5 meters from the subject’s thorax\n\nSlight elevation angle to optimize detection of chest-wall motion\n\nFMCW chirp time: 5 ms, chirp repetition frequency: 200 Hz\n\nData Acquisition Procedure:\n\nSubjects: 10 healthy adults (5 male, 5 female, 20–35 years), seated in a controlled environment\n\nEach radar collected a 60-second segment per subject\n\nSimultaneous recording from reference devices for validation\n\nSignal Processing & Validation:\n\nRange-FFT applied to IF signals to identify the dominant range bin corresponding to the torso\n\nPhase extraction from selected range bin, followed by bandpass Butterworth filtering (0.1–0.5 Hz for RR, 0.8–2.0 Hz for HR)\n\nZero-padded 512-point FFT applied, with peak detection for RR and HR estimation\n\nValidation metrics: Mean Absolute Error (MAE) and Pearson’s correlation coefficient (r) against reference devices\n\nExpected MAE: <2 breaths/min for RR, <3 beats/min for HR; r > 0.95 for both parameters\n\nSafety & Feasibility:\n\nNon-contact monitoring ensures subject comfort and safety\n\nSeated posture minimizes motion artifacts\n\nControlled lab environment for stable and repeatable measurements\n\nStatistical analysis performed to assess agreement between radar measurements and gold-standard references", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. The sampling rate of 5 kSPS is less than twice the maximum IF frequency of 8 kHz for the 60 GHz and 77 GHz radars, leading to aliasing and invalid data acquisition. Fix: Increase the sampling rate to at least 16 kSPS, such as reverting to 5 MSPS.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000380", "source_id": "da2690e12c13", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "valid", "protocol": "Protocol: EEG-Based Motor Imagery BCI Benchmark\nObjective: To establish a standardized benchmark for classifying left-hand versus right-hand motor imagery using an EEG-based brain-computer interface.\nEquipment: A research-grade, active electrode EEG system (e.g., g.tec g.USBamp or BioSemi ActiveTwo) with a minimum of 16 channels. Ag/AgCl electrodes. Sampling rate of 512 Hz. Amplifier settings with bandpass filter set to 0.1–100 Hz during acquisition and a 50/60 Hz notch filter enabled.\nSensor Placement & Configuration: Electrodes placed according to the international 10-20 system. A montage covering the sensorimotor cortex is required, including at least: Fz, C3, C4, Cz, CP3, CP4, P3, P4, O1, O2, with a reference at the left earlobe and ground at AFz. Electrode impedances must be kept below 5 kΩ.\nData Acquisition Procedure: Participants are 10 healthy, right-handed volunteers. Each trial begins with a 2-second fixation cross. A visual cue (arrow pointing left or right) then instructs the participant to perform kinesthetic motor imagery of the corresponding hand movement for 4 seconds, followed by a 2-second rest. A session comprises 100 trials (50 per class), randomized.\nSignal Processing & Validation: Pre-processing involves bandpass filtering raw EEG data from 8–30 Hz using a 4th-order Butterworth filter, with artifact rejection via thresholding (±100 µV) and visual inspection. Feature extraction uses the Common Spatial Pattern (CSP) algorithm applied to filtered data from channels C3, C4, Cz, CP3, CP4, and their immediate neighbors (e.g., FC3, FC4, CPz) to maximize variance discrimination between classes. The logarithm of the variance of the first and last two CSP components forms the feature vector. Classification is performed using a Linear Discriminant Analysis (LDA) classifier trained and evaluated with a 10-fold cross-validation scheme, stratified by participant. The primary performance metric is classification accuracy, with a benchmark target of 75 ± 5% for online-like performance (cross-validated), accounting for inter-subject variability.\nSafety & Feasibility: The protocol uses healthy volunteers and standard EEG procedures. Electrode impedances are controlled below 5 kΩ to ensure signal quality and participant safety. The experimental design is feasible with commonly available EEG equipment and established motor imagery tasks.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000381", "source_id": "2d848673c0b2", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous blood pressure (BP) estimation was performed using a custom wearable sensor integrating photoplethysmography (PPG) and electrocardiography (ECG). Participants underwent rest and mild exercise protocols while simultaneous reference BP measurements were collected. Pulse transit time (PTT) and pulse wave velocity (PWV) were derived for continuous BP tracking.\n\nObjective:\n\nTo evaluate the accuracy and reliability of a wearable PPG-ECG system for continuous, non-invasive BP estimation compared to clinical-grade oscillometric cuff measurements, and to validate compliance with AAMI standards.\n\nEquipment:\n\nCustom wrist-worn PPG-ECG sensor module\n\nMAX86150 analog front-end for PPG (green 530 nm, red 660 nm, infrared 940 nm LEDs; 100 Hz, 19-bit resolution)\n\nADS1298 analog front-end for ECG (single-lead Lead I and multi-lead Einthoven triangle; 70 Hz, 24-bit resolution)\n\n32.768 kHz synchronization clock\n\nClinical-grade oscillometric brachial cuff (SunTech Oscar 2) for reference\n\nSensor Placement & Configuration:\n\nThe PPG sensor was worn on the participant’s wrist over a standard watch strap for consistent contact. ECG electrodes were positioned for single-lead and multi-lead recordings according to standard placement guidelines. Both subsystems were synchronized via the common clock.\n\nData Acquisition Procedure:\n\nParticipants (n=30, including normotensive and hypertensive) were instrumented with the wearable module. Rest and mild exercise sessions were performed while PPG and ECG signals were continuously recorded. Reference BP measurements were acquired simultaneously using the brachial cuff. Calibration was performed per subject using two concurrent cuff measurements.\n\nSignal Processing & Validation:\n\nPPG signals were bandpass filtered (0.5–8 Hz, 4th-order Butterworth) to isolate pulsatile components. ECG signals were bandpass filtered (0.5–40 Hz, 4th-order Butterworth) and R-peaks were detected using the Pan-Tompkins algorithm. PTT was calculated as the time interval between ECG R-peak and corresponding PPG peak (second-derivative maximum method), averaged over 10-second windows. PWV was derived using estimated vascular path length. BP was estimated via a subject-specific linear regression model (BP = α * PTT + β). Performance was evaluated against the reference using mean error (ME), standard deviation of error (SDE), Pearson correlation coefficients, and Bland-Altman analysis. Target metrics were ME ≤ ±5 mmHg and SDE ≤ 8 mmHg per AAMI standards.\n\nSafety & Feasibility:\n\nThe wearable sensor module was non-invasive and worn on the wrist, ensuring participant safety. The protocol accommodated both rest and mild exercise conditions without risk, and sensor placement followed standard physiological monitoring guidelines. Calibration ensured accurate individualized measurements, and the system is feasible for continuous monitoring in clinical and ambulatory settings.", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG signal is bandpass filtered to 0.5–40 Hz, so the maximum frequency is 40 Hz. The required sampling rate is at least 80 Hz, but the protocol uses 70 Hz, which is insufficient and will cause aliasing, invalidating the ECG data and subsequent PTT calculations. Fix: Increase the ECG sampling rate to at least 80 Hz, such as 100 Hz or higher.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000393", "source_id": "8d8218292f48", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "valid", "protocol": "Protocol: Continuous Blood Pressure Estimation via PPG and ECG Pulse Wave Analysis\n\nObjective: To develop and validate a continuous blood pressure estimation method using photoplethysmography (PPG) and electrocardiography (ECG) pulse wave analysis in healthy adults.\n\nEquipment: A reflective, wrist-worn PPG sensor with green (530 nm), red (660 nm), and infrared (940 nm) LEDs and a photodetector; a single-lead ECG system with three adhesive Ag/AgCl electrodes; a continuous, non-invasive finger arterial pressure monitor (e.g., Finapres NOVA) as the reference system; and a 24-bit data acquisition system.\n\nSensor Placement & Configuration: The PPG sensor is positioned over the radial artery on the wrist. The ECG electrodes are placed at the right clavicle (RA), left clavicle (LA), and right lower abdomen (RL). The PPG sampling rate is 100 Hz, and the ECG sampling rate is 500 Hz.\n\nData Acquisition Procedure: Participants rest in a supine position for a 10-minute acclimatization period. Blood pressure is perturbed using validated physiological maneuvers (e.g., lower body negative pressure, isometric handgrip, Valsalva maneuver) to induce a range of BP values (±30 mmHg from baseline). All signals are simultaneously acquired via the 24-bit data acquisition system, with synchronization ensured by a common trigger pulse marking the start of each recording.\n\nSignal Processing & Validation: ECG R-peak detection is performed using bandpass filtering (0.5-40 Hz) and the Pan-Tompkins algorithm. PPG pulse detection uses the green channel filtered (0.5-8 Hz), with the peak of the second derivative (PPG\") identifying the pulse foot. Pulse Transit Time (PTT) is defined as the time interval between the ECG R-peak and the PPG pulse foot at the wrist. Pulse Wave Velocity (PWV) is estimated as the vascular distance (measured from sternal notch to wrist sensor) divided by PTT. Calibration involves establishing a linear regression model between measured PTT/PWV and reference systolic and diastolic BP values during stable baseline. Validation applies the model to data from the BP perturbation phase, with accuracy evaluated against the reference using Mean Error (ME) and Standard Deviation (SDE), targeting the clinical standard of ±5 mmHg.\n\nSafety & Feasibility: The study protocol is approved by an institutional review board. Participants are screened for cardiovascular conditions. BP perturbations are mild, monitored continuously, and stopped upon request.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000394", "source_id": "914dd67962a0", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG-Based Motor Imagery and P300 Speller Recording\n\nObjective:\n\nTo acquire and analyze EEG signals from multiple electrode configurations for motor imagery (MI) classification and P300 speller detection.\n\nEquipment:\n\ng.tec g.USBamp biosignal amplifier, 64 channels, 24-bit ADC, 512 Hz sampling\n\n16 active wet gel electrodes (g.LADYbird)\n\n8 dry electrodes (g.SCARABEO)\n\n2 in-ear electrodes (cEEGrid)\n\nMATLAB with EEGLAB and BCILAB toolboxes\n\nSensor Placement & Configuration:\n\nWet gel electrodes arranged according to 10-20 system over central-parietal regions (FC3, FC1, FCz, FC2, FC4, C3, C1, Cz, C2, C4, CP3, CP1, CPz, CP2, CP4, Pz)\n\nDry electrodes positioned over same central and parietal sites\n\nIn-ear electrodes (cEEGrid) in and around the ear\n\nReference: right earlobe; ground: FPz\n\nHardware bandpass filter 0.1–100 Hz, notch filter at 50 Hz\n\nData Acquisition Procedure:\n\nParticipants: 15 healthy adults (8 male, 7 female, 25±3 years)\n\nMotor imagery tasks: left hand, right hand, foot, 40 trials per class\n\nP300 speller: 6x6 matrix with row/column intensifications, 600 ms post-stimulus epochs\n\nSignals recorded simultaneously across all electrode types\n\nContinuous monitoring with real-time storage for offline processing\n\nSignal Processing & Validation:\n\nBandpass filtering: 8–30 Hz for MI, 1–20 Hz for P300\n\nArtifact rejection: automated thresholding (±100 µV) and ICA\n\nFeature extraction: Common Spatial Patterns (CSP) for MI, stepwise LDA (SWLDA) for P300\n\nClassification: shrinkage Linear Discriminant Analysis for MI\n\nValidation: 10x10-fold cross-validation\n\nPerformance metrics: classification accuracy (MI) and Information Transfer Rate (ITR) for P300\n\nExpected results: MI accuracy 75±5% (wet gel), 68±5% (dry), 62±5% (ear-EEG); P300 detection accuracy >90% for all sensor types\n\nSafety & Feasibility:\n\nNon-invasive recording with standard clinical safety precautions\n\nElectrodes maintained at appropriate impedance (<5 kΩ wet, <25 kΩ dry/ear)\n\nComfortable seating and breaks provided to participants to minimize fatigue and motion artifacts", "three_class_category": "Signal & Sampling", "violated_constraint": "snr_floor", "violated_principle": "Signal-to-noise floor violation", "why_invalid": "The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data will be acquired using a 64-channel g.tec g.USBamp biosignal (g.tec Medical Engineering GmbH, Austria) with a 24-bit ADC, sampling at 512 Hz..", "minimal_fix": "Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000396", "source_id": "d20e93d90317", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "valid", "protocol": "Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit\n\nObjective: To develop a benchmark dataset for silent speech recognition by capturing subvocalized speech using a throat microphone and associated head/jaw kinematics using an inertial measurement unit (IMU).\n\nEquipment: Throat Microphone: Piezoelectric contact microphone (e.g., ThoroComm TC-2000) with a frequency response of 100 Hz to 4000 Hz. Inertial Measurement Unit (IMU): 6-axis MEMS IMU (accelerometer ±16g, gyroscope ±2000°/s) with an internal sampling rate of 100 Hz. Data Acquisition: A 24-bit audio interface sampling the throat microphone at 48 kHz. A dedicated microcontroller synchronizes the IMU data stream with the audio stream via a common timestamp trigger.\n\nSensor Placement & Configuration: The throat microphone is placed firmly on the laryngeal prominence (Adam's apple) using an adjustable elastic band. The IMU is affixed to the chin or temple using medical-grade adhesive tape. During setup, the throat microphone is positioned over the larynx, and the IMU is attached to the participant's chin.\n\nData Acquisition Procedure: The participant sits in a quiet room (<40 dB SPL). The system is calibrated for a 5-second silent period. Participants are instructed to silently articulate (without phonation) a predefined list of 50 isolated words (e.g., \"hello,\" \"stop,\" \"go\") and 20 short phrases. Each utterance is repeated 10 times. The throat microphone captures mechanical vibrations from the vocal tract, while the IMU records micro-movements of the jaw and head.\n\nSignal Processing & Validation: Audio: Throat microphone signal is band-pass filtered (150-3500 Hz), normalized, and segmented by utterance triggers. Features extracted include 13 Mel-Frequency Cepstral Coefficients (MFCCs) and their first and second derivatives. IMU: Accelerometer and gyroscope data are low-pass filtered at 20 Hz to remove high-frequency noise. Features extracted include mean, variance, and peak frequency from the FFT of each axis. Data Fusion: Audio and IMU feature vectors are concatenated into a single multi-modal feature vector per utterance for classification. For a closed-vocabulary, speaker-dependent task, expected classification accuracy for isolated silent words is 85-92%. Accuracy for phrases is lower (75-85%) due to co-articulation effects. These figures are physically realistic given the high signal-to-noise ratio of direct contact sensing and the complementary information from kinematic data, but remain below conventional speech recognition due to the limited acoustic information.\n\nSafety & Feasibility: The experiment is conducted in a quiet room (<40 dB SPL) to minimize external noise interference. The use of medical-grade adhesive tape for sensor attachment ensures participant comfort and safety. The expected benchmark accuracy demonstrates feasibility for silent speech recognition using this multimodal approach.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000398", "source_id": "914dd67962a0", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG-Based Motor Imagery and P300 Recording with Multiple Electrode Configurations\n\nObjective:\n\nTo acquire and analyze EEG signals using wet, dry, and ear-EEG electrodes for motor imagery (MI) classification and P300 detection.\n\nEquipment:\n\ng.USBamp biosignal amplifier (g.tec Medical Engineering, Austria), 256 Hz sampling, 24-bit ADC, bandwidth 0.1–100 Hz\n\n32-channel wet gel EEG cap (g.LADYbird)\n\n16-channel dry EEG headset (g.SCARABEO)\n\nBilateral ear-EEG arrays (cEEGrid, 10 electrodes per ear)\n\nPsychtoolbox-3 for stimulus presentation\n\nMATLAB with EEGLAB and custom processing scripts\n\nSensor Placement & Configuration:\n\nWet gel electrodes positioned according to extended 10-20 system\n\nDry electrodes targeting central and parietal regions\n\nEar-EEG arrays placed bilaterally around the ears\n\nForehead ground and linked-mastoid reference for all recordings\n\nData Acquisition Procedure:\n\nParticipants perform kinesthetic motor imagery of left hand, right hand, and feet\n\nEach trial: 2 s fixation, 1.5 s cue, 4 s imagery, 1 s rest\n\n100 trials per class per session\n\nSeparate sessions for wet, dry, and ear-EEG recordings\n\nVisual cues presented via Psychtoolbox-3\n\nSignal Processing & Validation:\n\nBandpass filtering: 1–45 Hz (MI), 1–12 Hz (P300), 50 Hz notch filter, 4th-order Butterworth\n\nFeature extraction: Common Spatial Patterns (CSP) log-variance for MI; temporal sampling for P300\n\nClassification: regularized Linear Discriminant Analysis (LDA)\n\nValidation: 10-fold cross-validation within subjects, leave-one-subject-out for cross-subject generalization\n\nPerformance metrics: classification accuracy and Information Transfer Rate (ITR)\n\nExpected results: wet electrodes >75% accuracy, dry >65%, ear-EEG >60%, ITR >15 bits/min\n\nStatistical analysis: repeated-measures ANOVA\n\nSafety & Feasibility:\n\nNon-invasive EEG recording with standard clinical safety\n\nComfortable seating and breaks provided to minimize fatigue and motion artifacts\n\nElectrode impedances monitored and maintained within acceptable ranges", "three_class_category": "Signal & Sampling", "violated_constraint": "snr_floor", "violated_principle": "Signal-to-noise floor violation", "why_invalid": "The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data will be acquired using a g.USBamp biosignal (g.tec Medical Engineering, Austria) with a sampling rate of 256 Hz and a 24-bit analog-to-digital converter..", "minimal_fix": "Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000406", "source_id": "cc94bf30c229", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Tracking Using Multi-Modal PPG and ECG\n\nObjective:\n\nTo continuously estimate blood pressure (BP) non-invasively using pulse transit time (PTT) derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals.\n\nEquipment:\n\nPPG sensor: ADPD4100 reflectance sensor (Analog Devices) with green (530 nm), red (660 nm), and infrared (850 nm) LEDs, 500 Hz sampling, 18-bit resolution\n\nSingle-lead ECG: pre-gelled Ag/AgCl electrodes, FE132 amplifier (ADInstruments), 1000 Hz sampling, 24-bit resolution, 0.05–150 Hz bandwidth\n\nReference multi-lead ECG: Mac 2000, GE Healthcare\n\nOscillometric calibration cuff: BPBIO750, InBody\n\nIntra-arterial BP reference: Sola, Solaris\n\nMATLAB workstation for signal processing\n\nSensor Placement & Configuration:\n\nPPG sensor secured to left wrist over stainless steel watch band\n\nSingle-lead ECG electrodes placed on right wrist and left ankle\n\n12-lead ECG applied according to standard clinical placement for reference R-peak timing\n\nAll devices synchronized for accurate PTT measurement\n\nData Acquisition Procedure:\n\nParticipants: healthy adult subjects\n\n5-minute calibration period with oscillometric cuff, readings every 2 minutes\n\nContinuous PPG and ECG acquisition during rest and experimental tasks\n\nBeat-to-beat BP estimation validated in a subset using intra-arterial measurements\n\nPTT averaged over 10 consecutive beats to reduce variability\n\nSignal Processing & Validation:\n\nPPG: bandpass filtered 0.5–8 Hz (4th-order Butterworth) to isolate pulse wave\n\nECG: bandpass filtered 0.5–40 Hz; R-peaks detected using Pan-Tompkins algorithm\n\nPTT: calculated as interval between ECG R-peak and foot of PPG pulse wave (minimum of second derivative)\n\nBeat-to-beat SBP and DBP estimated via subject-specific linear models: SBP = α * PTT + β, DBP = γ * PTT + δ\n\nPerformance evaluated against continuous intra-arterial BP using mean error, standard deviation, and compliance with AAMI/ISO 81060-2:2018 standards\n\nSafety & Feasibility:\n\nNon-invasive sensors minimize participant risk\n\nWrist and ankle placements are comfortable and do not impede movement\n\nSystem designed for continuous monitoring with beat-to-beat estimation\n\nExpected performance: ±5 mmHg mean error and standard deviation <8 mmHg, meeting clinical validation standards", "three_class_category": "Perception & Anatomy", "violated_constraint": "optical_obstruction", "violated_principle": "Optical signal-path obstruction", "why_invalid": "Optical obstruction: PPG relies on unobstructed light transmission/reflection, and opaque materials block the optical path. The stainless steel watch band is opaque to the PPG wavelengths (530 nm, 660 nm, 850 nm), preventing light from reaching the photodetector. This results in no detectable PPG signal, making PTT calculation and BP estimation impossible, as the system requires a valid pulse wave for processing. Fix: Place the PPG sensor on bare skin without any opaque obstruction, such as on the left index finger as originally specified.", "minimal_fix": "Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000407", "source_id": "90d109278d81", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous-wave vital sign monitoring was performed using three FMCW radar modules to non-invasively measure respiration and heart rate in seated subjects.\n\nObjective:\n\nTo assess the accuracy of different radar frequency bands (77 GHz, 60 GHz, 24 GHz) for continuous non-contact monitoring of respiration and heart rate, validated against physiological reference sensors.\n\nEquipment:\n\n77 GHz FMCW radar: Texas Instruments IWR1443, 4 GHz bandwidth, 2.7 cm range resolution\n\n60 GHz FMCW radar: Infineon BGT60TR13C, 7 GHz bandwidth, 2.1 cm range resolution\n\n24 GHz FMCW radar: Silicon Labs Si24R1, 250 MHz bandwidth, 60 cm range resolution\n\nPiezoelectric respiration belt: ADInstruments MLT1132\n\nPulse oximeter: Nonin 3150\n\nData acquisition hardware and MATLAB for signal processing\n\nSensor Placement & Configuration:\n\nAll radar modules positioned 1.5 m from the seated participant\n\nAntennas aimed at the thoracic region\n\nSubject thorax range typically 1.2–1.8 m\n\nData Acquisition Procedure:\n\nTen healthy adults (5 male, 5 female, ages 25–35) participated in 5-minute resting sessions\n\nRadar intermediate frequency (I/Q) data sampled at 0 kSPS for 77/60 GHz and 2 MSPS for 24 GHz\n\nDetection range: 1.0–3.0 m\n\nSignal Processing & Validation:\n\n2D Fast Fourier Transform (2D-FFT) applied to raw I/Q signals to generate range-Doppler maps\n\nThorax range bin selected, and static clutter removed using a high-pass filter at 0.05 Hz\n\nPhase signals processed through two parallel bandpass filters: 0.1–0.5 Hz for respiration and 0.8–2.0 Hz for heart rate\n\nVital signs estimated using peak detection on the power spectral density of each filtered signal\n\nValidation metrics: Mean Absolute Error (MAE) and Pearson correlation coefficient (r) against reference sensors\n\nExpected performance: respiration MAE < 0.8 breaths/min, r > 0.95; heart rate MAE < 1.5 beats/min, r > 0.90\n\nSafety & Feasibility:\n\nNon-contact radar ensures participant safety and minimal interference\n\nReference sensors provide gold-standard validation\n\nThe 77 GHz system expected to deliver the highest accuracy due to superior range resolution and signal-to-noise ratio\n\nProtocol feasible for controlled indoor monitoring of vital signs over short sessions", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "The acquisition setting violates the Nyquist-Shannon sampling requirement. The sampling rate is insufficient for the highest retained signal frequency, so aliasing can corrupt the measured signal and invalidate downstream analysis. In this sample, the problematic modification is: Each radar was positioned 1.5 meters from a seated human subject, with the antenna beam directed at the thorax..", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000420", "source_id": "cc45683dad38", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nSurface electromyography (sEMG) signals were recorded from the dominant forearm using three electrode types across separate sessions to evaluate hand gesture recognition.\n\nObjective:\n\nTo compare the performance of wet gel, dry, and high-density electrode configurations for classifying static hand gestures using sEMG.\n\nEquipment:\n\nWet gel Ag/AgCl electrodes (Ambu BlueSensor N)\n\nDry stainless steel electrodes (Delsys Bagnoli handheld probe)\n\nHigh-density linear electrode array (OT Bioelettronica, 16 channels)\n\nDelsys Trigno Avanti wireless acquisition system (2000 Hz sampling, 16-bit ADC, 20-450 Hz bandwidth, CMRR >120 dB)\n\nMATLAB 2023b for signal processing and analysis\n\nSupport Vector Machine (RBF kernel) classifier\n\nSensor Placement & Configuration:\n\nWet gel, dry, and high-density electrodes positioned over flexor digitorum superficialis, extensor digitorum communis, flexor carpi radialis, extensor carpi radialis longus, and brachioradialis muscles\n\nBipolar configuration for wet gel electrodes\n\nReference electrode placed on the olecranon process\n\nHigh-density array aligned to the same muscle regions for comparison\n\nData Acquisition Procedure:\n\nParticipants: 15 healthy adults\n\nTask: 10 repetitions of 8 static hand gestures (e.g., fist, wrist flexion, key grip)\n\nContraction duration: 5 seconds per gesture with 10-second rest intervals\n\nData streamed wirelessly and synchronized via Delsys Trigno Avanti system\n\nSignal Processing & Validation:\n\nBandpass filtering: 2nd-order Butterworth (20–400 Hz)\n\nNotch filter at 60 Hz to remove powerline interference\n\nRectification and smoothing using 150 ms RMS window\n\nFeature extraction: time-domain features (RMS, waveform length) and 6th-order autoregressive coefficients from 200 ms windows with 50 ms overlap\n\nClassification: SVM with RBF kernel, evaluated with leave-one-subject-out cross-validation\n\nPerformance metrics: classification accuracy, F1-score, confusion matrices\n\nExpected accuracy: wet gel 88–95%, dry electrodes 82–90%, high-density array 92–97%\n\nSafety & Feasibility:\n\nNon-invasive electrodes ensure participant safety\n\nShort-duration contractions with adequate rest minimize fatigue and discomfort\n\nSystem achieves <0.1 ms end-to-end latency", "three_class_category": "Signal & Sampling", "violated_constraint": "latency_constraint", "violated_principle": "System latency infeasibility", "why_invalid": "The claimed end-to-end latency is incompatible with the stated communication or processing path. The transmission and computation delays exceed the required control-loop timing budget. In this sample, the problematic modification is: Surface electromyography (sEMG) signals were recorded from the dominant forearm using three electrode types in separate sessions..", "minimal_fix": "Replace the unrealistic latency claim with a feasible timing budget, or use a local wired or otherwise low-latency processing path.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000430", "source_id": "8d8218292f48", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "valid", "protocol": "Protocol: Continuous Blood Pressure Estimation via Pulse Transit Time (PTT)\n\nObjective: To estimate continuous blood pressure using Pulse Transit Time (PTT) derived from ECG and PPG signals.\n\nEquipment: PPG sensor (reflectance-mode with green 530 nm and IR 940 nm LEDs), single-lead ECG system, clinically validated oscillometric blood pressure cuff.\n\nSensor Placement & Configuration: Place the PPG sensor on the palmar side of the proximal phalanx of the index finger with firm, stable contact. Place ECG electrodes on the right and left wrists, with a ground electrode on the ankle. Configure the PPG sensor for a sampling rate of 100 Hz with a 24-bit ADC. Configure the ECG system for a sampling rate of 500 Hz with a 24-bit ADC. Ensure all systems share a common ground and are time-synchronized via a hardware trigger or synchronized clocks.\n\nData Acquisition Procedure: Conduct an initial calibration session with each subject. Simultaneously record PTT and measure reference blood pressure using the oscillometric cuff on the contralateral upper arm. Collect 3-5 paired measurements over 5 minutes while the subject is seated and resting. After a 10-minute rest period, continuously record PTT and estimate BP for 20 minutes. Simultaneously, acquire reference BP measurements every 5 minutes via the cuff.\n\nSignal Processing & Validation: Apply a 0.5-5 Hz bandpass filter to the PPG signal to isolate the pulsatile component. Apply a 0.5-40 Hz bandpass filter to the ECG signal. Automatically detect ECG R-peaks and the foot of the PPG pulse wave (defined as the point of minimum diastolic pressure before the systolic upstroke). For each heartbeat, compute the Pulse Transit Time (PTT) as the time delay between the ECG R-peak and the subsequent PPG foot. Use the calibration data to fit a linear regression model (BP = a*PTT + b) for the individual. Calculate the Mean Absolute Error (MAE) and standard deviation against the reference to validate accuracy against the AAMI standard (MAE ≤ 5 mmHg, SD ≤ 8 mmHg).\n\nSafety & Feasibility: The protocol is feasible if accuracy meets these clinical standards.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000439", "source_id": "10ad40eaa2fc", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol:\n\nSilent Speech Recognition Using MEMS Contact Microphone and 9-Axis IMU\n\nObjective:\n\nTo capture subvocalization vibrations and laryngeal movements for silent speech recognition and evaluate classification performance on a 100-word vocabulary.\n\nEquipment:\n\nMEMS contact microphone (Knowles SPU0410LR5H-QB) with integrated anti-aliasing filter\n\n9-axis IMU (InvenSense ICM-20948)\n\nData acquisition system (National Instruments USB-6356)\n\nMATLAB or equivalent software for signal processing and feature extraction\n\nSupport vector machine (SVM) classifier with radial basis function kernel\n\nSensor Placement & Configuration:\n\nMicrophone affixed to skin over the thyroid cartilage to capture laryngeal vibrations\n\n9-axis IMU positioned adjacent to the microphone to measure acceleration, angular velocity, and magnetic field\n\nBoth sensors synchronized via the data acquisition system\n\nData Acquisition Procedure:\n\nMicrophone sampled at 32,000 Hz with 24-bit resolution, 80–4000 Hz bandwidth\n\nIMU sampled at 50 Hz with 16-bit resolution for accelerometer (±16 g), gyroscope (±2000 dps), and magnetometer (±4900 µT)\n\nTwenty healthy participants (10 male, 10 female; ages 20–35) silently articulated 100 words, each repeated 10 times across five sessions\n\nData streamed to the acquisition system for synchronized recording\n\nSignal Processing & Validation:\n\nMicrophone signals bandpass filtered (80–4000 Hz, 4th-order Butterworth), segmented into 25 ms frames with 10 ms overlap\n\nFeatures extracted: 13 MFCCs and energy per frame\n\nIMU signals low-pass filtered (50 Hz cutoff); features extracted: mean, variance, peak amplitude per axis\n\nFeatures normalized and concatenated into a single vector per frame\n\nSVM classifier trained on 80% of data; 20% reserved for testing using 5-fold cross-validation\n\nPerformance metrics: accuracy, precision, recall, F1-score; expected accuracy 92% with F1 > 0.90\n\nSafety & Feasibility:\n\nNon-invasive, skin-mounted sensors with adhesive and stable placement\n\nComfortable for participants during silent articulation tasks\n\nSystem robust for high-resolution, synchronized acquisition under laboratory conditions", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem The IMU sampling rate of 50 Hz is less than twice the maximum signal frequency of 50 Hz (from the low-pass filter cutoff), violating the Nyquist criterion and making accurate signal reconstruction impossible due to aliasing. Fix: Increase the IMU sampling rate to at least 100 Hz to satisfy the Nyquist theorem.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000442", "source_id": "d3a9a880386f", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "valid", "protocol": "Protocol: Throat Microphone and IMU Silent Speech Data Acquisition\nObjective: To collect synchronized, high-fidelity vibration and motion data from a throat microphone and inertial measurement unit (IMU) during silent and spoken articulation for silent speech recognition model development.\nEquipment: Throat Microphone: MEMS contact microphone (e.g., Knowles SPH0645LM4H-B) with flat frequency response (50 Hz - 10 kHz) and integrated preamplifier. IMU: 9-axis (3-axis accelerometer, gyroscope, magnetometer) with ±16g, ±2000 dps, and ±4900 µT ranges (e.g., Bosch BNO055). Data Acquisition: Multi-channel 24-bit ADC (e.g., National Instruments USB-4431) or a custom PCB integrating both sensors. Microphone sampling rate: 16 kHz. IMU sampling rate: 200 Hz. Mounting: Medical-grade adhesive patch for microphone; adjustable elastic neck strap for IMU.\nSensor Placement & Configuration: The MEMS microphone is securely adhered over the thyroid cartilage (Adam's apple) on the midline of the anterior neck. The IMU is mounted on the same adhesive patch or a rigid, non-elastic extension from it, ensuring firm contact with the skin to capture laryngeal elevation/depression and hyoid bone movement.\nData Acquisition Procedure: Calibration: Record 10 seconds of silence to establish baseline noise levels. Perform a 5-second head/neck range-of-motion sequence for IMU orientation calibration. Task: The participant performs a silent articulation task (e.g., mouthing words from a 100-word vocabulary list). Each trial consists of a 2-second preparation period, the silent articulation, and a 1-second rest. Repeat each word 5 times. Control Trials: Record the same words spoken aloud at a normal conversational volume for direct comparison and labeling. Synchronization: Both sensor streams are timestamped by the same master clock (ADC or microcontroller) to ensure sub-millisecond alignment.\nSignal Processing & Validation: Pre-processing: Apply a 4th-order Butterworth bandpass filter (80-4000 Hz) to the microphone signal to isolate subvocalization vibrations. Apply a low-pass filter (40 Hz) to IMU data to remove high-frequency vibration artifacts. Feature Extraction: Extract Mel-frequency cepstral coefficients (MFCCs) and spectral features from the microphone signal. Extract magnitude, jerk, and orientation quaternion features from the IMU data. Validation: The primary validation metric is the Word Error Rate (WER) of a baseline classifier (e.g., a small convolutional neural network) trained on the silent speech data and tested on a held-out set. A WER significantly below chance confirms the data's utility. The correlation between silent and spoken acoustic envelopes provides an additional signal quality check.\nSafety & Feasibility: Written informed consent will be obtained. The protocol will be approved by the Institutional Review Board (IRB).", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000449", "source_id": "92ef014ff9c8", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "fatal_violation", "protocol": "Protocol:\n\nEEG Recording and Analysis for Motor Imagery and P300 Speller Using Multiple Electrode Technologies\n\nObjective:\n\nTo compare the performance of wet gel, dry, and ear-EEG electrodes for motor imagery (MI) classification and P300 speller tasks, evaluating classification accuracy, information transfer rate, and signal quality.\n\nEquipment:\n\n64-channel g.tec g.USBamp system with g.LADYbird active wet gel electrodes (24-bit ADC, 512 Hz, 0.1–100 Hz bandpass)\n\n24-channel Wearable Sensing DSI-24 dry EEG system (16-bit ADC, 150 Hz, 1–100 Hz bandpass)\n\n16-channel Natus EEGear ear-EEG system with around-the-ear electrodes (24-bit ADC, 250 Hz)\n\nComputer with Python and MNE-Python for signal processing\n\nCommon average reference for all systems\n\nSensor Placement & Configuration:\n\nWet gel electrodes placed according to standard 64-channel montage\n\nDry electrodes positioned over central and parietal regions\n\nEar-EEG electrodes placed around the ear concha and lobule\n\nAll systems referenced to common average\n\nData Acquisition Procedure:\n\nParticipants performed cue-based MI tasks (left hand, right hand, feet) and a P300 speller task using a 6×6 character matrix\n\nMI epoch: 0.5 s pre-cue to 3.5 s post-cue, 40 trials per class\n\nP300 epoch: 0.2 s pre-stimulus to 0.8 s post-stimulus, 200 stimuli with 20% targets\n\nSignals acquired simultaneously from all three systems and synchronized via software triggers\n\nSignal Processing & Validation:\n\nContinuous EEG bandpass filtered (1–40 Hz) and notch filtered (50/60 Hz)\n\nIndependent Component Analysis (ICA) to remove ocular and muscle artifacts\n\nMI features extracted using Common Spatial Patterns (CSP) from 8–30 Hz band, classified using Linear Discriminant Analysis (LDA)\n\nP300 epochs averaged per character and classified using stepwise LDA (SWLDA)\n\n10-fold cross-validation within each session\n\nMetrics: classification accuracy, information transfer rate (ITR), and Area Under the Curve (AUC)\n\nExpected performance: MI >70% accuracy, P300 >95% accuracy\n\nSafety & Feasibility:\n\nNon-invasive EEG recording with standard electrode application procedures\n\nParticipants seated comfortably in an electrically shielded room\n\nNo adverse effects anticipated\n\nApproved by institutional review board and conducted following ethical guidelines", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. With a sampling rate of 150 Hz and a hardware filter allowing frequencies up to 100 Hz, the maximum signal frequency (100 Hz) exceeds the Nyquist frequency (75 Hz), causing aliasing and rendering the sampled data invalid for accurate signal reconstruction. Fix: Increase the sampling rate of the DSI-24 system to at least 200 Hz to satisfy the Nyquist criterion for the 100 Hz filter cutoff.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000457", "source_id": "6c03fa294aab", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nVital sign monitoring was performed using three commercial FMCW radar modules across different frequency bands to assess non-contact respiration and heart rate measurement.\n\nObjective:\n\nTo evaluate the accuracy and reliability of 24 GHz, 60 GHz, and 77 GHz FMCW radars in estimating respiration rate (RR) and heart rate (HR) in seated human subjects.\n\nEquipment:\n\nTexas Instruments AWR1642 radar module (77–81 GHz, 4 GHz bandwidth)\n\nTexas Instruments IWR6843 radar module (60–64 GHz, 4 GHz bandwidth)\n\nTexas Instruments AWR1843 radar module (24–24.25 GHz, 250 MHz bandwidth)\n\nNasal thermistor for respiration rate reference\n\nThree-lead electrocardiogram (ECG) for heart rate reference\n\nSensor Placement & Configuration:\n\nRadars positioned 2.0 meters from a seated subject, antenna arrays perpendicular to the thorax\n\nChirp repetition frequency set to 1 kHz\n\nSampling rate: 0.1 MSPS\n\nDetection range: 1.0–3.0 m\n\nData Acquisition Procedure:\n\nRaw I/Q data collected from each radar module during 5-minute sessions per subject\n\nTen healthy participants recorded\n\nSimultaneous reference measurements collected via nasal thermistor and ECG\n\nSignal Processing & Validation:\n\nProcessing pipeline:\n\nRange FFT to generate range profiles\n\nClutter removal using 5th-order Butterworth high-pass filter (0.05 Hz cutoff)\n\nSelection of range bin with maximum thoracic power\n\nExtraction of vital signs via bandpass filtering (0.1–0.5 Hz for respiration, 0.8–2.0 Hz for heart rate)\n\nInstantaneous RR and HR estimated via peak detection on power spectral density (Welch’s method, 10 s Hanning windows, 50% overlap)\n\nPerformance metrics: Mean Absolute Error (MAE) and Pearson correlation coefficient (r) against reference signals\n\nSafety & Feasibility:\n\nNon-contact radar monitoring ensures participant comfort and safety\n\nExpected performance: MAE < 1 breaths/min for RR, MAE < 2 beats/min for HR, with r > 0.95 for both measures across all radar frequencies\n\nSetup feasible for repeated 5-minute recording sessions in a controlled environment", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. For the 77 GHz radar with 4 GHz bandwidth and chirp repetition frequency of 1 kHz (chirp time 1 ms), the maximum beat frequency for a target at 3.0 m is approximately 80 kHz, requiring a Nyquist sampling rate of at least 160 kHz. A sampling rate of 0.1 MSPS (100 kSPS) is below this threshold, causing aliasing and invalidating the signal processing for range and vital signs extraction. Fix: Increase the sampling rate to at least 0.2 MSPS (200 kSPS) to satisfy the Nyquist criterion for the highest beat frequency.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000468", "source_id": "3688437fbf54", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "minor_issue", "protocol": "Protocol:\n\nIMU-Based Motion Capture for Daily Activity Recognition\n\nObjective:\n\nTo capture acceleration and angular velocity signals using wearable IMUs for activity recognition during daily movements.\n\nEquipment:\n\n9-axis IMU (accelerometer ±16g, gyroscope ±2000 dps, magnetometer)\n\nAdjustable straps and adhesive pads for sensor attachment\n\nWireless data logger for streaming IMU data to a host computer\n\nShielded room to control electromagnetic interference\n\nSensor Placement & Configuration:\n\nIMUs attached to the participant’s right wrist and right ankle\n\nSensors secured with straps and adhesive pads to minimize motion artifacts\n\nSampling rate set to 410 Hz for all sensor axes\n\nData Acquisition Procedure:\n\nParticipants: 15 healthy adults (ages 20–40) without mobility impairments\n\nCalibration: static calibration for 10 seconds on a non-metallic surface to correct sensor biases\n\nActivity protocol: walking at 1.5 m/s, running at 3 m/s, sitting, standing, ascending stairs\n\nEach activity performed for 3 minutes with 1-minute rest intervals between activities\n\nContinuous streaming of IMU data via wireless data logger\n\nSignal Processing & Validation:\n\nRaw acceleration signals filtered using a 4th-order Butterworth low-pass filter at 200 Hz\n\nAngular velocity signals filtered at 2000 Hz\n\nFeature extraction: mean, variance, and other relevant metrics per sliding window\n\nActivity classification using a Random Forest model\n\nValidation: 5-fold cross-validation; expected recognition accuracy >90%\n\nSafety & Feasibility:\n\nNon-invasive wearable sensors with secure attachment\n\nInformed consent obtained, data anonymized\n\nExperimental environment controlled to minimize interference and ensure reproducibility", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Suboptimal but physically feasible experimental design.", "why_invalid": "The protocol remains physically feasible, but Objective: To establish a protocol for IMU-based motion capture and activity recognition, focusing on capturing acceleration and angular velocity signals during daily activities.. The protocol remains physically feasible, but the sampling or filtering margin is weak. This can reduce temporal precision, narrow the anti-aliasing transition band, or degrade feature quality, although the target signal can still be acquired. It is not a fatal violation because the target measurement can still be acquired under the stated sensing modality.", "minimal_fix": "Increase the sampling rate or adjust the effective analysis bandwidth to provide a more robust signal-processing margin.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000473", "source_id": "2ae7c707acc8", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nComparative evaluation of non-contact vital sign monitoring using three FMCW radar modules at 77 GHz, 60 GHz, and 24 GHz, measuring respiration and heart rates simultaneously.\n\nObjective:\n\nTo quantify the accuracy of multi-frequency FMCW radars in extracting respiration rate (RR) and heart rate (HR) from seated human subjects under controlled conditions.\n\nEquipment:\n\n77 GHz radar: Texas Instruments IWR1443, 4 GHz bandwidth\n\n60 GHz radar: Infineon BGT60LTR11, 5.5 GHz bandwidth\n\n24 GHz radar: Aconno ACN524, 2 GHz bandwidth\n\nClinical references: Masimo Rad-97 pulse oximeter (HR), nasal thermistor (RR)\n\nMATLAB for signal processing and analysis\n\nSensor Placement & Configuration:\n\nRadars positioned 1.5 m from seated subjects\n\nAntenna beams directed toward the thoracic region\n\nChirp repetition frequency: 1 kHz; equivalent baseband sampling: 1 kSPS per range bin\n\nEnvironment Robustness test: 5 mm aluminum plate between radar and subject\n\nRange resolution: 3.75 cm (77 GHz), 2.7 cm (60 GHz), 7.5 cm (24 GHz)\n\nData Acquisition Procedure:\n\nTen healthy volunteers (5 male, 5 female, 25 ± 3 years) recorded\n\nMeasurement sessions lasted 60 seconds\n\nSubjects remained stationary during acquisition\n\nSimultaneous reference measurements recorded for HR and RR\n\nSignal Processing & Validation:\n\n2D FFT applied to IF data to generate Range-Doppler Maps\n\nThorax range bin identified via maximum power in static clutter map\n\nPhase signal φ(t) extracted and unwrapped over 30-second windows\n\n5th-order Butterworth bandpass filters applied: 0.1–0.5 Hz (RR), 0.8–2.0 Hz (HR)\n\nRR and HR estimated via peak detection in filtered signals\n\nValidation metrics: MAE and Pearson correlation coefficient (r) against references\n\nObserved MAE: 77 GHz – 0.8 breaths/min RR, 1.2 bpm HR; 60 GHz – 0.9/1.3; 24 GHz – 1.5/2.1\n\nPearson r: >0.98 HR, >0.96 RR across all sensors\n\nSafety & Feasibility:\n\nNon-contact measurement ensures no physical risk to participants\n\nControlled laboratory setting with electromagnetic shielding\n\nHigher-frequency radars provide superior resolution and sensitivity to small thoracic displacements, demonstrating feasibility for accurate vital sign monitoring", "three_class_category": "Physical / Hardware", "violated_constraint": "ematerial_block", "violated_principle": "Physical medium or propagation blockage", "why_invalid": "The inserted material blocks or severely attenuates the physical propagation path required by the sensing modality. As a result, the sensor cannot receive the target signal under the stated configuration. In this sample, the problematic modification is: Three distinct FMCW radar modules were employed for comparative evaluation: a 77 GHz IWR1443 (Texas Instruments) with 4 GHz bandwidth, a 60 GHz BGT60LTR11 (Infineon) with 5.5 GHz bandwidth, and a 24 GHz ACN524 (Aconno) with 2 GHz bandwidth..", "minimal_fix": "Remove or replace the blocking material so that the relevant acoustic, optical, or electromagnetic propagation path remains unobstructed.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000487", "source_id": "cb626c87603b", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Monitoring Using a Wrist-Worn PPG-ECG Device\n\nObjective:\n\nTo perform beat-to-beat blood pressure (BP) tracking using a wrist-worn device that integrates photoplethysmography (PPG) and electrocardiography (ECG) sensors, calibrated against a standard oscillometric reference and validated against continuous arterial measurements.\n\nEquipment:\n\nWrist-worn PPG sensor (Maxim Integrated MAX30102, 24-bit ADC) with green (525 nm), red (660 nm), and infrared (880 nm) LEDs\n\nWrist-to-wrist single-lead ECG module (Analog Devices AD8232, 24-bit ADC, 0.5–40 Hz bandwidth) with Ag/AgCl electrodes\n\nReference 12-lead ECG system (GE MAC 5500 HD) for R-peak validation\n\nOscillometric sphygmomanometer (Omron HEM-907XL) for calibration\n\nContinuous finger arterial BP monitor (Finapres NOVA) for validation\n\nMATLAB R2023b for signal processing and analysis\n\nSensor Placement & Configuration:\n\nPPG sensor positioned on the wrist, protected by a stainless steel cover\n\nSingle-lead ECG electrodes placed in a wrist-to-wrist configuration\n\n12-lead reference ECG applied per manufacturer guidelines\n\nAll sensors synchronized via software timestamps\n\nData Acquisition Procedure:\n\nPPG sampled at 100 Hz; ECG sampled at 500 Hz\n\nProtocol included 3 minutes of resting baseline, mild exercise (cycling at 50 W), and post-exercise recovery\n\nContinuous acquisition of PPG and ECG signals for each participant (N=30, age 25–40)\n\nSignal Processing & Validation:\n\nPPG signals bandpass filtered (0.5–8 Hz); pulse onset detected via derivative-based algorithm\n\nECG signals bandpass filtered (0.5–40 Hz); R-peaks detected using Pan-Tompkins algorithm\n\nPulse Transit Time (PTT) computed as interval between ECG R-peak and corresponding PPG pulse onset\n\nSubject-specific linear calibration: BP = a * (1/PTT) + b, trained on 3 minutes of resting data from an oscillometric cuff\n\nModel updated daily with a single brachial BP measurement\n\nContinuous BP estimates compared against finger arterial line reference (Finapres NOVA)\n\nPerformance metrics: mean error (ME), standard deviation of error (SDE), Pearson correlation coefficient (r)\n\nSafety & Feasibility:\n\nNon-invasive, wrist-worn monitoring suitable for repeated measurements\n\nExercise and postural changes conducted under controlled conditions\n\nTarget performance: ME ± SDE ≤ 0 ± 5 mmHg, compliant with ISO 81060-2:2018 standards for clinical BP monitoring", "three_class_category": "Perception & Anatomy", "violated_constraint": "optical_obstruction", "violated_principle": "Optical signal-path obstruction", "why_invalid": "optical_obstruction – PPG relies on light transmission/reflection; opaque obstacles block optical path. The stainless steel cover is opaque to the PPG wavelengths (525 nm, 660 nm, 880 nm), completely blocking light from the LEDs from reaching the skin and preventing any reflected light from being detected, rendering PPG signal acquisition impossible and invalidating the experiment. Fix: Replace the stainless steel cover with a transparent material or remove it to ensure direct optical access to the skin.", "minimal_fix": "Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000490", "source_id": "6596c6eba1d9", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture and Activity Recognition\n\nObjective: To capture full-body kinematics and classify ambulatory activities using a minimal, wearable inertial measurement unit (IMU) setup.\n\nEquipment: Five 9-axis IMU units (e.g., Xsens MTw), each containing a tri-axial accelerometer (range: ±16g), tri-axial gyroscope (range: ±2000 dps), and tri-axial magnetometer. Units connect wirelessly to a host PC via a dedicated receiver.\n\nSensor Placement & Configuration: Units are affixed to the participant using elastic straps at five anatomical landmarks: sternum (L4 vertebra level), right thigh (mid-segment, anterior), right shank (mid-segment, anterior), left thigh, and left shank. Alignment follows the ISB recommendations for segment coordinate systems. All units sample synchronously at 100 Hz. This rate exceeds the Nyquist frequency for human motion (typically <20 Hz), preventing aliasing. Data packets are timestamped at the receiver.\n\nData Acquisition Procedure: Participants perform a calibration step by assuming a static N-pose (standing, arms at sides) for 10 seconds to establish sensor-to-segment alignment and compute initial orientation via gravity and magnetic north vectors. Subsequently, participants perform a predefined sequence of activities: standing, walking at self-selected speed, running, stair ascent, stair descent, and sitting. Each activity is performed for 30 seconds and repeated three times.\n\nSignal Processing & Validation: Raw accelerometer and gyroscope data are pre-processed by calibrating using manufacturer-supplied bias and scale factor matrices, followed by applying a 4th-order Butterworth low-pass filter with a cutoff frequency of 20 Hz to remove high-frequency noise. Orientation estimation is performed using a complementary filter that fuses accelerometer and gyroscope data with a time constant of 1 second, trading off dynamic response and drift reduction. Magnetometer data is used for heading correction during locomotion. For activity recognition, real-time data is processed using the complementary filter for orientation estimation, and a classifier (e.g., Random Forest) uses features from 2-second sliding windows, including mean and variance of angular velocity, signal magnitude area, and thigh/shank angular range, to categorize the six activities. Accuracy claims state that static orientation accuracy is within ±1.5° for roll and pitch and ±3° for heading. Segment position derived via double integration of linear acceleration is subject to drift; thus, only orientation-based kinematic parameters such as joint angles and angular velocities are reported. Activity classification accuracy is expected to exceed 95% for the specified activities in a controlled lab environment.\n\nSafety & Feasibility:", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000491", "source_id": "cf27c42eb92a", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nsEMG Acquisition and Gesture Recognition from Calf Musculature Using Multiple Electrode Configurations\n\nObjective:\n\nTo acquire and compare surface electromyography (sEMG) signals from the dominant calf using wet-gel, dry, and high-density electrode arrays, and to evaluate gesture recognition performance across electrode types.\n\nEquipment:\n\ng.tec g.USBamp biosignal amplifier with 8-channel wet-gel Ag/AgCl electrodes (Kendall H135SG)\n\nDelsys Trigno Avanti wireless system with 4 dry stainless steel electrodes\n\nOT Bioelettronica Sessantaquattro 16-channel high-density dry electrode array\n\nMATLAB for signal processing\n\nClassification software: Linear Discriminant Analysis (LDA) and Support Vector Machine (SVM)\n\nSensor Placement & Configuration:\n\nElectrodes placed in a bipolar configuration over gastrocnemius, soleus, tibialis anterior, and peroneus longus following SENIAM guidelines\n\nReference electrode positioned per manufacturer recommendations\n\nRandomized order of electrode configurations across participants\n\ng.USBamp: 2400 Hz sampling rate, 24-bit ADC, 10–500 Hz bandpass\n\nDelsys: 2000 Hz, 16-bit, 20–450 Hz bandwidth\n\nSessantaquattro: 2000 Hz, 24-bit, 10–500 Hz bandwidth\n\nData Acquisition Procedure:\n\nFifteen healthy, right-handed participants (age 25±3 years)\n\nEach participant performs 10 repetitions of 12 static gestures (fist, wrist flexion/extension, finger pinch), held for 5 seconds with 3-second rest intervals\n\nData streamed or recorded simultaneously according to electrode system specifications\n\nSignal Processing & Validation:\n\n50 Hz notch filter applied to remove powerline interference\n\nFull-wave rectification\n\nSegmentation into 250 ms windows with 50 ms overlap\n\nFeature extraction: Root Mean Square (RMS), Waveform Length (WL), 4th-order autoregressive coefficients\n\nClassification using LDA and SVM with radial basis function kernel\n\nPerformance assessed with 10-fold cross-validation\n\nRepeated measures ANOVA used to compare electrode types\n\nAdditional metrics: accuracy, precision, recall, F1-score, and confusion matrices\n\nSafety & Feasibility:\n\nNon-invasive sEMG acquisition on healthy adult participants\n\nAdherence to ethical approval and informed consent\n\nMinimal risk with standard electrode application and calibrated equipment\n\nExpected recognition accuracy: >95% for wet-gel and high-density arrays, >90% for dry electrodes", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement Calf muscles do not generate sEMG signals for hand gestures; signals from them will not correlate with the intended gestures, making classification invalid. For example, the expected accuracy of 95% for wet-gel systems cannot be achieved as the data source is anatomically incorrect. Fix: Revert the electrode placement to the dominant forearm muscles as originally specified.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000494", "source_id": "03026a9cce63", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "fatal_violation", "protocol": "Protocol:\n\nFull-body motion capture and activity recognition using a multi-IMU wearable system.\n\nObjective:\n\nTo accurately capture human kinematics and classify daily activities using inertial measurement units (IMUs), validated against an optical motion capture system.\n\nEquipment:\n\nSeven Xsens MTi-3 9-axis IMUs (accelerometer ±16g, 16-bit; gyroscope ±2000 dps, 16-bit; magnetometer for absolute heading)\n\nTwo Bosch BMI088 6-axis IMUs (accelerometer ±24g, 16-bit; gyroscope ±2000 dps, 16-bit)\n\nCustom Bluetooth 5.0 data logger with ±10 µs timestamp accuracy\n\n8-camera optical motion capture system (Qualisys Oqus, 100 Hz)\n\nSensor Placement & Configuration:\n\nIMUs affixed with medical-grade adhesive and elastic bands on sternum, lumbar spine (L3), bilateral upper arms, forearms, thighs, and shanks\n\nMTi-3 units provide magnetometer-based absolute heading\n\nBMI088 units placed on high-acceleration limbs\n\nSynchronized sampling at 200 Hz, system bandwidth: 50 Hz (accelerometer) and 52 Hz (gyroscope)\n\nData Acquisition Procedure:\n\nParticipants perform standardized movements including gait and reach-and-grab tasks\n\nData logged continuously via the Bluetooth 5.0 system\n\nTen repetitions of each activity for validation\n\nStatic calibration poses used to align sensor frames to anatomical frames\n\nSignal Processing & Validation:\n\nOrientation estimated using Madgwick filter (β=0.1) fusing accelerometer, gyroscope, and magnetometer (MTi-3 only)\n\nAcceleration and angular velocity signals low-pass filtered with 4th-order Butterworth filter (80 Hz cutoff)\n\nActivity recognition performed on 2-second sliding windows (50% overlap)\n\nTime-domain features: mean, variance, zero-crossings; frequency-domain features: spectral energy, entropy\n\nSupport Vector Machine (SVM) with RBF kernel trained and validated on extracted features\n\nKinematic validation against optical motion capture system; RMSE <5°, Pearson correlation r >0.95\n\nActivity classification accuracy expected >95% across 10 daily activities (sitting, standing, walking, stair ascent/descent, etc.)\n\nStatistical evaluation includes Bland-Altman limits of agreement for angular measurements\n\nSafety & Feasibility:\n\nNon-invasive IMUs with secure attachment to prevent slippage\n\nSufficient bandwidth and sampling to capture natural motion without aliasing\n\nFeasible for real-time activity recognition and motion analysis in controlled laboratory settings", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "sensor_bandwidth The sensor bandwidth is set to 50 Hz for accelerometer and 52 Hz for gyroscope, but the low-pass filter allows frequencies up to 80 Hz. Frequencies above 50 Hz (e.g., from high-acceleration movements) will not be accurately captured by the sensors, leading to aliasing or distorted signals, invalidating frequency-domain features like spectral energy. Fix: Set the low-pass filter cutoff frequency to be less than or equal to the sensor bandwidth, such as 20 Hz or lower.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000498", "source_id": "214cea5e14a8", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nHigh-Resolution sEMG Acquisition and Gesture Classification Using Multi-Modal Electrode Configurations\n\nObjective:\n\nTo record and analyze surface electromyography (sEMG) signals from the dominant upper arm across wet-gel, dry, and high-density electrode arrays, and to classify hand gestures and wrist movements with high accuracy using time, frequency, and spatial features.\n\nEquipment:\n\nWet-gel electrodes: Ambu BlueSensor N (8 electrodes, bipolar configuration)\n\nDry electrode array: Delsys Trigno Avanti (16 channels, circumferential placement)\n\nHigh-density semi-dry array: OT Bioelettronica (64 channels, 8×8 grid, 10 mm inter-electrode distance)\n\nData acquisition system: OT Bioelettronica Sessantaquattro, 24-bit ADC, 2000 Hz sampling rate, 10–900 Hz hardware bandpass, 50/60 Hz notch filter\n\nMATLAB R2023a for signal processing\n\nCNN (two convolutional layers) for HD-sEMG spatial feature extraction\n\nLinear Discriminant Analysis (LDA) classifier\n\nSensor Placement & Configuration:\n\nWet-gel electrodes positioned over the biceps brachii muscle following SENIAM guidelines\n\nDry electrode array placed circumferentially around the proximal upper arm\n\nHD-sEMG array positioned over the same muscle group\n\nStandardized skin preparation: shaving, abrasion with NuPrep, and cleaning with alcohol\n\nReference electrode placement consistent across configurations\n\nData Acquisition Procedure:\n\nParticipants: 10 healthy adults (5 male, 5 female, age 25 ± 3 years)\n\nTask: 10 repetitions of 10 discrete hand gestures (fist, wrist flexion, finger pinch, etc.) and 5 wrist movements\n\nTrial duration: each gesture held for 5 seconds with 5-second inter-trial intervals\n\nSignals acquired simultaneously from all three electrode configurations\n\nSampling: 2000 Hz, 24-bit ADC, hardware bandpass 10–900 Hz, notch at 50/60 Hz\n\nSignal Processing & Validation:\n\nDigital bandpass filter: 20–500 Hz, 4th-order Butterworth\n\nNotch filter: 50 Hz to remove powerline interference\n\nSegmentation: 250 ms windows with 50 ms overlap\n\nFeature extraction:\n\nTime-domain: RMS, waveform length, zero crossings\n\nFrequency-domain: median frequency, mean power frequency\n\nSpatial features (HD array) via CNN with two convolutional layers\n\nClassification: LDA for 10 discrete gestures and 5 wrist movements\n\nValidation: 5-fold cross-validation\n\nMetrics: classification accuracy, F1-score, confusion matrix analysis\n\nSafety & Feasibility:\n\nStandard skin preparation ensures consistent signal quality\n\nNon-invasive electrodes and anatomical landmarks minimize participant risk\n\nExpected accuracy: 92 ± 3% for wet-gel and dry electrodes; 96 ± 2% for HD-sEMG\n\nProtocol ensures reproducibility and reliable signal acquisition across all sensor types", "three_class_category": "Perception & Anatomy", "violated_constraint": "anatomical_misplacement", "violated_principle": "Anatomical placement inconsistency", "why_invalid": "anatomical_misplacement: sensors placed on anatomy that does not generate the target physiological signal for hand gesture recognition. The biceps brachii muscle primarily controls elbow flexion, not fine hand movements. sEMG signals from this location lack correlation with hand gestures, rendering the classification task invalid. Expected accuracies of 92-96% are unattainable as the signals do not contain relevant information for recognizing 10 discrete hand gestures and 5 wrist movements. Fix: Reposition all electrodes to the forearm over extrinsic hand muscles such as flexor digitorum superficialis and extensor digitorum communis.", "minimal_fix": "Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.", "difficulty": "easy", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000501", "source_id": "cc45683dad38", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "fatal_violation", "protocol": "Protocol:\n\nForearm sEMG Acquisition and Gesture Recognition Across Multi-Modal Electrode Configurations\n\nObjective:\n\nTo investigate the impact of wet-gel, dry, and high-density sEMG electrode configurations on finger gesture recognition performance, with high temporal and spatial resolution for real-time applications.\n\nEquipment:\n\nWet-gel electrodes: Ambu BlueSensor N (20 mm inter-electrode distance)\n\nDry electrodes: Delsys Trigno Avanti sensors (built-in)\n\nHigh-density array: TMSi REFA-128 (8×8 grid, 4 mm spacing)\n\nData acquisition: National Instruments USB-6363, 24-bit ADC, 2000 Hz sampling, 10–900 Hz bandpass, 50/60 Hz notch filter\n\nMATLAB R2023b for signal processing\n\nLinear Discriminant Analysis (LDA) classifier\n\nSensor Placement & Configuration:\n\nWet-gel electrodes applied over forearm muscles following skin preparation\n\nDry electrodes integrated in the Trigno sensors, positioned over the same muscle groups\n\nHD array circumferentially placed on the forearm\n\nElectrode impedances verified before recording (<5 kΩ for wet gel, <20 kΩ for dry)\n\nAll sensor systems synchronized via a common trigger pulse\n\nData Acquisition Procedure:\n\nParticipants: healthy adults (number unspecified) performing five discrete finger movements and a resting state\n\nRecording: 2000 Hz sampling rate with 24-bit ADC\n\nEach gesture repeated multiple times in a controlled protocol\n\nReal-time streaming achieved with total end-to-end latency <0.1 ms\n\nSignal Processing & Validation:\n\nOffline bandpass filtering: 20–500 Hz, 4th-order Butterworth\n\nSegmentation: 250 ms sliding windows with 75% overlap\n\nFeature extraction: time-domain (RMS, waveform length, slope sign changes) and autoregressive coefficients (order 6)\n\nFeature vector computed per channel\n\nClassification using LDA\n\nValidation via 10-fold cross-validation stratified by participant\n\nSafety & Feasibility:\n\nSkin prepared and electrodes verified for low impedance\n\nSynchronized multi-modal acquisition ensures reliable data\n\nWireless and cloud transmission introduce negligible latency\n\nExpected classification accuracy: >90% for wet and dry electrodes with ≥8 channels; >95% for high-density array", "three_class_category": "Signal & Sampling", "violated_constraint": "latency_constraint", "violated_principle": "System latency infeasibility", "why_invalid": "The claimed end-to-end latency is incompatible with the stated communication or processing path. The transmission and computation delays exceed the required control-loop timing budget. In this sample, the problematic modification is: Surface electromyography (sEMG) signals were recorded using three electrode configurations to assess their impact on gesture recognition performance..", "minimal_fix": "Replace the unrealistic latency claim with a feasible timing budget, or use a local wired or otherwise low-latency processing path.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000504", "source_id": "d5a4c4e1f93d", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "valid", "protocol": "Protocol:\n\nNon-Contact Vital Signs Monitoring using 60 GHz FMCW Radar.\n\nObjective:\n\nTo monitor respiration and heart rate using non-contact 60 GHz FMCW radar.\n\nEquipment:\n\nThe radar module is a 60 GHz FMCW radar transceiver, such as Infineon BGT60TR13C, with a 5 GHz bandwidth from 57–64 GHz. This provides a range resolution of approximately 3 cm.\n\nThe antenna uses integrated patch antennas with a beamwidth of approximately 80° azimuth and 30° elevation.\n\nThe processing unit is a microcontroller or single-board computer, such as Raspberry Pi 4, for data acquisition and processing.\n\nSensor Placement & Configuration:\n\nThe subject is seated, relaxed, in a static environment, facing the radar. The radar is placed 0.5–1.0 meters from the subject’s sternum, at the same height, ensuring direct line-of-sight to the thorax.\n\nThe environment is controlled to minimize moving clutter, including no fans or other people.\n\nData Acquisition Procedure:\n\nThe chirp repetition frequency is 100 Hz, corresponding to 10 ms per chirp. This is well above the Nyquist rate for both respiration, typically 0.1–0.5 Hz, and heart rate, 0.8–2.0 Hz.\n\nEach chirp contains 256 ADC samples. The sampling rate per chirp is 25.6 MHz. The number of chirps per frame is 100, yielding a frame rate of 1 Hz, since 100 chirps multiplied by 10 ms equals 1 second.\n\nThe total recording duration is 30 seconds per measurement epoch.\n\nSignal Processing & Validation:\n\nFor each chirp, a 256-point FFT is performed on the raw I/Q data to generate a range profile. The range bin corresponding to the subject’s chest, such as bin 17 for a 0.5 m distance, is identified.\n\nThe phase history of the complex signal at the identified range bin is extracted across the 100 chirps in a frame. Static clutter and DC offset are removed by applying a high-pass filter with a 0.1 Hz cutoff or subtracting the mean phase over the frame.\n\nFor respiration extraction, a 1024-point FFT is performed on the filtered phase signal. The dominant peak in the 0.1–0.5 Hz band is the respiration rate.\n\nFor heart rate extraction, a 0.8–2.0 Hz band-pass filter is applied to the phase signal, followed by a 1024-point FFT. The dominant peak in this band is the heart rate. Zero-padding and parabolic interpolation are used for improved frequency resolution.\n\nExpected accuracy in a controlled setting is respiration rate within ±1 breath per minute and heart rate within ±3 BPM, compared to a clinical reference such as capnograph and ECG.\n\nSafety & Feasibility:\n\nThe subject is seated, relaxed, in a static environment, facing the radar. The radar is placed 0.5–1.0 meters from the subject’s sternum with direct line-of-sight to the thorax. The environment is controlled to minimize moving clutter.\n\nThe protocol’s feasibility is based on the radar’s bandwidth providing sufficient spatial resolution to isolate chest wall motion, and the chirp repetition frequency being high enough to prevent aliasing of the vital sign frequencies.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000510", "source_id": "50172d3ff07d", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "valid", "protocol": "Protocol: IMU-Based Motion Capture and Activity Recognition\n\nObjective: To validate a wearable inertial measurement unit (IMU) system for accurate 3D motion capture and classification of common human activities (e.g., walking, sitting, stair ascent/descent).\n\nEquipment: IMU Sensors: 5x commercially available 9-axis IMUs (e.g., Xsens MTw, APDM Opal). Specifications: Tri-axial accelerometer (±16g range), tri-axial gyroscope (±2000 dps range), tri-axial magnetometer. Sampling rate set to 100 Hz via Bluetooth dongle. Host System: Laptop with dedicated data acquisition software.\n\nSensor Placement & Configuration: IMUs are firmly attached to the following segments using medical-grade straps: mid-thorax (sternum), left/right upper shank (posterior, between malleoli and knee joint), and left/right lower thigh (anterior, just superior to patella). Prior to data collection, a static calibration is performed with the subject standing in a neutral anatomical pose to establish a sensor-to-segment coordinate system alignment. A dynamic calibration (e.g., N-pose, T-pose) is used to refine magnetometer-based heading estimates.\n\nData Acquisition Procedure: All IMUs are hardware-synchronized via a dedicated sync unit, and data collection is initiated with a manual trigger. Participants (N=15 healthy adults) perform a standardized sequence: 1 minute quiet standing (static), 10m straight-line walking at self-selected speed (5 trials), 5x sit-to-stand from a chair, and 5x stair ascent/descent (3 steps). Concurrent optical motion capture (e.g., Vicon, 12 cameras, 100 Hz) provides gold-standard joint kinematics for the lower limbs, and activity labels are manually annotated from video.\n\nSignal Processing & Validation: Raw accelerometer and gyroscope data are low-pass filtered (4th-order Butterworth, cutoff 20 Hz) to remove high-frequency noise. Joint angles (knee flexion/extension, hip flexion) are computed via sensor fusion algorithms (e.g., Madgwick filter), and accuracy is assessed by calculating the Root Mean Square Error (RMSE) against the optical system reference. A machine learning pipeline (e.g., Random Forest classifier) is trained on time-domain and frequency-domain features extracted from each 1-second window of IMU data, and model performance is evaluated using leave-one-subject-out cross-validation, reporting overall accuracy and F1-score.\n\nSafety & Feasibility: The protocol is physically feasible, using established sensor technology and placements. The sampling rate (100 Hz) is sufficient for human movement analysis. Validation against a gold-standard system provides a robust metric for motion capture accuracy (target RMSE < 5°). The classification task tests the system's practical utility for activity recognition.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000513", "source_id": "8d8218292f48", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "valid", "protocol": "Protocol: Continuous Blood Pressure Estimation via PTT/PWV Using Synchronized PPG and ECG\n\nObjective: To develop and validate a continuous, non-invasive blood pressure (BP) tracking system by measuring Pulse Transit Time (PTT) and Pulse Wave Velocity (PWV) derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals.\n\nEquipment: PPG sensor: A wrist-worn reflective module containing green (530 nm), red (660 nm), and IR (940 nm) LEDs and a photodetector, with a sampling rate of 500 Hz. ECG sensor: A single-lead, chest-strap ECG (e.g., Ag/AgCl electrodes, Lead I configuration) with a sampling rate of 1000 Hz. Reference BP monitor: A validated, oscillometric upper-arm cuff (e.g., FDA-cleared device) for calibration and validation, providing systolic (SBP) and diastolic (DBP) values.\n\nSensor Placement & Configuration: The PPG sensor is placed on the dorsal wrist over the radial artery and secured with a light band to minimize motion artifact. The ECG chest strap is attached securely to the chest. The reference BP monitor is used on the upper arm for calibration and validation.\n\nData Acquisition Procedure: The subject rests supine for 5 minutes. Skin is cleaned with alcohol wipes. The ECG chest strap is attached securely, and the PPG sensor is placed on the dorsal wrist over the radial artery, secured with a light band. All devices are connected to a central data acquisition unit (DAQ) with a common clock. Two minutes of baseline data are recorded. Simultaneously, three consecutive cuff BP measurements are obtained and averaged for initial calibration. Synchronized PPG and ECG signals are recorded during a 10-minute protocol encompassing rest, mild mental stress (e.g., arithmetic), and post-stress recovery.\n\nSignal Processing & Validation: For ECG, a 0.5-40 Hz bandpass filter is applied, and R-peaks are detected using a Pan-Tompkins algorithm. For PPG, a 0.5-15 Hz bandpass filter is applied, and the foot (onset) of the PPG pulse wave is identified using the second derivative maximum. PTT is calculated as the time delay between the ECG R-peak and the PPG pulse foot at the wrist, computed beat-to-beat. PWV is estimated as the distance (approximated as 80% of subject's height) divided by PTT. Using the baseline cuff BP and average PTT/PWV, an initial linear regression model is established: SBP = a1*ln(PTT) + b1; DBP = a2*ln(PTT) + b2, with coefficients a and b individualized. During the protocol, the cuff takes intermittent BP measurements (e.g., every 2 minutes). Continuous BP estimates derived from real-time PTT are compared against these reference values, with performance assessed using mean error ± standard deviation, meeting the clinical standard of ≤ ±5 mmHg with a standard deviation ≤ 8 mmHg.\n\nSafety & Feasibility: This protocol uses commercially available, wearable-grade sensors. The sampling rates are sufficient for high-fidelity morphology analysis. The calibration step is essential for individual arterial compliance. Motion artifacts are the primary challenge, mitigated by the controlled supine setup.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000514", "source_id": "8d8218292f48", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "valid", "protocol": "Protocol: Continuous Blood Pressure Estimation via PPG-ECG Pulse Transit Time\n\nObjective: To develop and validate a continuous, non-invasive blood pressure (BP) estimation model using Pulse Transit Time (PTT) derived from synchronously acquired photoplethysmography (PPG) and electrocardiography (ECG) signals.\n\nEquipment: PPG Sensor: Reflectance-type sensor with green (525 nm), red (660 nm), and infrared (940 nm) LEDs and a photodetector. Sampling rate: 100 Hz. ECG System: Single-lead ECG (Lead I or II) using disposable Ag/AgCl electrodes. Sampling rate: 250 Hz. Reference BP Monitor: A continuous, non-invasive beat-to-beat finger arterial pressure device (e.g., Finapres NOVA) for calibration and validation. Data Acquisition System: Multi-channel analog-to-digital converter with anti-aliasing filters (e.g., Biopac MP160).\n\nSensor Placement & Configuration: PPG sensor on the index finger of the non-dominant hand. ECG electrodes placed on the right clavicle and left lower ribcage. Reference BP cuff on the middle finger of the same hand as the PPG. All signals will be time-stamped by the acquisition system to ensure precise alignment.\n\nData Acquisition Procedure: Subject Preparation: Rest in a supine position for 10 minutes in a temperature-controlled room (22-24°C). Data Collection Protocol: Baseline (5 min): Record resting supine data. Perturbation (10 min): Induce BP variations via isometric handgrip exercise (30% MVC) and/or a Valsalva maneuver, followed by recovery. Total Recording: ~15 minutes per subject.\n\nSignal Processing & Validation: Pre-processing: Bandpass filter ECG (0.5-40 Hz) and PPG (0.5-10 Hz) to remove baseline wander and high-frequency noise. Feature Detection: Identify the ECG R-peak (QRS complex) and the PPG pulse foot (minimum point before systolic upstroke) using validated peak-detection algorithms. PTT Calculation: PTT is defined as the time delay between the ECG R-peak and the corresponding PPG pulse foot at the finger. This will be calculated on a beat-to-beat basis. Calibration: For each subject, use the first 5 minutes of baseline data to establish an individualized linear regression model relating PTT to systolic BP (SBP) and diastolic BP (DBP) from the reference device. Validation: Use the remaining data (perturbation and recovery) to test the model. Performance will be evaluated against the reference BP using Mean Absolute Error (MAE), Standard Deviation of Error (SDE), and Pearson correlation coefficient (r). The target accuracy is an MAE ≤ 5 mmHg and SDE ≤ 8 mmHg, per the ISO 81060-2 standard for non-invasive BP devices.\n\nSafety & Feasibility:", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000516", "source_id": "73ef42c14345", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Estimation Using Pulse Transit Time from Synchronized PPG and ECG\n\nObjective:\n\nTo estimate beat-to-beat systolic and diastolic blood pressure non-invasively using pulse transit time (PTT) derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals, and validate accuracy against reference measurements.\n\nEquipment:\n\nWearable PPG sensor: Maxim Integrated MAX86150, green (525 nm), red (660 nm), infrared (940 nm) LEDs, photodetector, 100 Hz sampling, 19-bit resolution\n\nSingle-lead ECG: Analog Devices AD8232, 250 Hz sampling, 24-bit resolution\n\n12-lead ECG: Texas Instruments ADS1299, 250 Hz sampling, 24-bit resolution\n\nReference blood pressure devices: Finapres NOVA (non-invasive) or arterial line (invasive)\n\nSignal acquisition and processing software (MATLAB or equivalent)\n\nSensor Placement & Configuration:\n\nPPG sensor positioned on a finger or wrist for distal measurement\n\nECG electrodes configured with single-lead on standard limb leads and 12-lead system for calibration\n\nAll sensors time-synchronized using shared sampling clock\n\nBandpass filters applied: PPG 0.5–5 Hz; ECG 0.05–150 Hz, 4th-order Butterworth\n\nData Acquisition Procedure:\n\nThirty healthy adult participants recruited for the study\n\nBaseline period of 5 minutes for linear calibration model per subject\n\nExperimental protocol includes rest, isometric handgrip, and Valsalva maneuver\n\nSimultaneous acquisition of PPG and ECG signals, and reference BP using Finapres NOVA\n\nContinuous beat-to-beat recording for each condition\n\nSignal Processing & Validation:\n\nECG R-peaks detected from lead II using standard algorithms\n\nPPG pulse wave foot identified from infrared channel via second-derivative maximum method\n\nPTT calculated as the interval between ECG R-peak and PPG foot\n\nSubject-specific linear calibration model: PTT = a·ln(BP) + b\n\nContinuous BP estimated from calibrated PTT\n\nValidation metrics: mean absolute error (MAE), mean error (ME), correlation coefficient (r)\n\nTarget performance: ME ≤ ±5 mmHg, SD ≤ 8 mmHg; PTT-BP r > 0.85, MAE < 7 mmHg for systolic BP\n\nSafety & Feasibility:\n\nNon-invasive measurements minimize risk; invasive arterial-line used only where clinically justified\n\nProtocol approved by institutional review board and informed consent obtained\n\nStudy conducted under controlled conditions to ensure participant safety and signal quality", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG bandpass filter is set to 0.05–150 Hz, so the maximum frequency is 150 Hz. The Nyquist rate requires at least 300 Hz sampling, but 250 Hz is below this, leading to aliasing and invalid signal acquisition for accurate PTT calculation. Fix: Increase the ECG sampling rate to at least 300 Hz, such as 1000 Hz as in the original protocol.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000521", "source_id": "54cc1242ebdb", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol:\n\nSilent speech recognition using a custom throat-mounted sensor array combining a MEMS contact microphone and a 9-axis IMU.\n\nObjective:\n\nTo capture subvocalization signals and laryngeal motion for real-time classification of a 100-word silent speech vocabulary.\n\nEquipment:\n\nMEMS contact microphone (Knowles SPH0645LM4H-B, 65 dB SNR, 150 Hz–10 kHz)\n\n9-axis IMU (ICM-20948, accelerometer ±16 g, gyroscope ±2000 dps)\n\nUSB audio interface (Focusrite Scarlett Solo) for microphone acquisition\n\nI2C interface for IMU acquisition\n\n3D-printed housing with silicone coupling pad\n\nMATLAB / Python-based signal processing and 1D convolutional neural network for classification\n\nSensor Placement & Configuration:\n\nMicrophone and IMU co-located in the housing\n\nAssembly centered over the thyroid cartilage\n\nAudio sampled at 16 kHz, 24-bit resolution\n\nIMU sampled at 100 Hz\n\nData synchronized via a TTL trigger pulse\n\nData Acquisition Procedure:\n\n20 healthy participants silently articulate 100 words from the TIMIT corpus, each repeated five times\n\nParticipants seated in a quiet environment, instructed to minimize motion\n\nReal-time synchronization of audio and IMU streams\n\nSignal Processing & Validation:\n\nAudio: 4th-order Butterworth bandpass filter (80–4000 Hz) to isolate subvocalization\n\nIMU: roll, pitch, yaw estimated via complementary filter (0.5 s time constant)\n\nFeature extraction: 25 ms windows with 10 ms overlap, computing 13 MFCCs for audio; mean, variance, zero-crossing rate for IMU\n\nClassification: 1D CNN with 3 convolutional layers and 2 dense layers\n\nData split: 80% training, 10% validation, 10% testing\n\nPerformance metrics: classification accuracy, F1-score, confusion matrices\n\nExpected word accuracy: 85–92%, with higher confusion between phonetically similar words\n\nSafety & Feasibility:\n\nNon-invasive, secure throat-mounted assembly\n\nLow-latency processing (~120 ms), suitable for real-time applications\n\nParticipants monitored for comfort and safety during silent articulation sessions", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Sensor bandwidth must cover signal frequency content. The microphone bandwidth starts at 150 Hz, but the bandpass filter is set to 80–4000 Hz, so frequencies between 80 Hz and 150 Hz are not captured by the sensor, making the experiment invalid as critical low-frequency subvocalization vibrations are missed. Fix: Use a microphone with a lower frequency bound of 80 Hz or less to align with the bandpass filter.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000534", "source_id": "2f956bb4792c", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "fatal_violation", "protocol": "Protocol:\n\nNeck-worn sensor array for silent speech recognition, combining a MEMS contact microphone and a 9-axis IMU to capture subvocalization and laryngeal kinematics.\n\nObjective:\n\nTo evaluate the feasibility and accuracy of a multimodal neck-worn sensor system for silent speech recognition across a 200-word vocabulary using combined acoustic and motion features.\n\nEquipment:\n\nMEMS contact microphone (Knowles SPU0410LR5H-QB, 50–10,000 Hz, -38 dBV/Pa)\n\n9-axis IMU (InvenSense ICM-42688-P, ±16 g accelerometer, ±2000°/s gyroscope)\n\nLow-noise amplifier with 40 dB gain and 4th-order Butterworth anti-aliasing filter (cutoff 8 kHz)\n\nCustom data acquisition system\n\nPython 3.x signal processing environment with relevant libraries\n\nSensor Placement & Configuration:\n\nMicrophone affixed over the thyroid cartilage with medical adhesive\n\nIMU positioned 2 cm superior to the microphone on the neck\n\nMicrophone digitized at 16 kHz, 8-bit ADC\n\nIMU sampled at 200 Hz via internal ADC\n\nHardware timestamps used for synchronization\n\nData Acquisition Procedure:\n\nTen healthy participants (5 male, 5 female)\n\nEach participant performed five repetitions of 200 silent speech words\n\nContinuous simultaneous acquisition of microphone and IMU signals\n\nSignal Processing & Validation:\n\nMicrophone: 4th-order Butterworth bandpass filter (80–4000 Hz) and mean normalization\n\nIMU: Complementary filter fusing accelerometer and gyroscope data for angular displacement\n\nFeature extraction: 25 ms Hamming windows with 10 ms shift; 13 MFCCs plus first and second derivatives for audio; peak velocity and displacement for IMU\n\nLSTM network (2 layers, 128 units) trained using leave-one-subject-out cross-validation; 80% training data, 20% held-out test\n\nPerformance metrics: Word Error Rate (WER) <15%, system latency <300 ms\n\nSignal-to-noise ratio (SNR) of microphone >20 dB\n\nSafety & Feasibility:\n\nNon-invasive neck-worn configuration\n\nSafe for repeated use on human participants\n\nApproved under institutional review\n\nProtocol feasible for real-time silent speech recognition in a quiet laboratory environment", "three_class_category": "Signal & Sampling", "violated_constraint": "adc_resolution", "violated_principle": "ADC resolution limitation", "why_invalid": "The ADC resolution is too coarse for the expected signal amplitude. The quantization step can exceed meaningful physiological signal variations, preventing reliable measurement. In this sample, the problematic modification is: The microphone was affixed over the thyroid cartilage using medical adhesive, while the IMU was secured 2 cm superiorly..", "minimal_fix": "Use a higher-resolution ADC and, where needed, an analog front-end with appropriate gain so that the expected low-amplitude signal can be resolved.", "difficulty": "hard", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000550", "source_id": "d1f779307b4d", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "fatal_violation", "protocol": "Protocol:\n\nContinuous Blood Pressure Estimation Using a Wearable PPG-ECG Device\n\nObjective:\n\nTo estimate beat-to-beat systolic and diastolic blood pressure non-invasively using pulse transit time derived from synchronized PPG and single-lead ECG signals in healthy adults during rest and mild exercise.\n\nEquipment:\n\nPPG module: Maxim Integrated MAX86150, green (530 nm), red (660 nm), infrared (940 nm) LEDs with photodetector, 100 Hz sampling, 19-bit resolution\n\nECG module: Analog Devices AD8232, single-lead configuration, Ag/AgCl electrodes, 50 Hz sampling, 24-bit resolution, 0.5–40 Hz bandwidth\n\nBluetooth Low Energy interface for data transmission\n\nHost computer with MATLAB (MathWorks) for signal processing\n\nReference devices: Finapres NOVA finger PPG and Tango+ oscillometric cuff\n\nSensor Placement & Configuration:\n\nPPG sensor mounted on the wrist with appropriate optical contact\n\nSingle-lead ECG electrodes placed in standard wrist-to-wrist configuration\n\nSynchronization of PPG and ECG signals via BLE to host computer\n\nCalibration performed per subject with a 2-minute baseline measurement\n\nData Acquisition Procedure:\n\nParticipants: 30 healthy adults, age 25–40\n\nProtocol duration: 30 minutes including rest, mild cycling exercise at 50 W, and recovery\n\nContinuous recording of PPG and ECG signals during all phases\n\nReference BP measured simultaneously with Finapres NOVA and validated with oscillometric cuff\n\nSignal Processing & Validation:\n\nPPG: bandpass filtered 0.5–5 Hz (4th-order Butterworth)\n\nECG: bandpass filtered 0.5–30 Hz (4th-order Butterworth)\n\nECG R-peaks detected using Pan-Tompkins algorithm\n\nPPG pulse onset detected via second-derivative maximum\n\nPulse Transit Time (PTT) calculated per beat\n\nSubject-specific linear regression model relating PTT to systolic and diastolic BP\n\nPerformance metrics: Mean Error (ME) ≤ ±5 mmHg, Standard Deviation (SD) ≤ 8 mmHg\n\nPTT-BP correlation expected >0.85 for systolic pressure\n\nValidation against reference devices per AAMI ISO 81060-2 standards\n\nSafety & Feasibility:\n\nNon-invasive wearable design with low-risk optical and ECG sensors\n\nSuitable for use during rest and mild exercise without interfering with participant activity\n\nContinuous monitoring verified for stable operation and data integrity\n\nDevice confirmed to comply with physiological measurement standards and safety guidelines", "three_class_category": "Signal & Sampling", "violated_constraint": "sampling_theorem", "violated_principle": "Signal sampling infeasibility", "why_invalid": "Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG signal is bandpass filtered to 0.5–30 Hz, so the maximum frequency is 30 Hz. The Nyquist rate requires a sampling rate of at least 60 Hz to avoid aliasing, but the ECG is sampled at 50 Hz, which is less than 60 Hz, making the signal processing invalid due to aliasing. Fix: Increase the ECG sampling rate to at least 60 Hz, such as the original 500 Hz, to satisfy the Nyquist criterion.", "minimal_fix": "Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000555", "source_id": "85250c997977", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "fatal_violation", "protocol": "Protocol:\n\nA controlled laboratory study using three FMCW radar systems to non-invasively monitor cardiopulmonary activity in seated participants, with cross-validation against clinical reference devices.\n\nObjective:\n\nTo evaluate the accuracy of non-contact respiration rate (RR) and heart rate (HR) measurements across three FMCW radar systems operating at different frequencies (77 GHz, 60 GHz, 24 GHz).\n\nEquipment:\n\n77 GHz radar: Texas Instruments IWR1443, 4 GHz bandwidth\n\n60 GHz radar: Texas Instruments AWR1642, 3.6 GHz bandwidth\n\n24 GHz radar: Infineon BGT24MTR11, 1.5 GHz bandwidth\n\nMasimo Rad-97 pulse CO-oximeter (HR reference)\n\nPiezoelectric respiratory belt (RR reference)\n\nMATLAB for signal processing and analysis\n\nSensor Placement & Configuration:\n\nParticipants seated 1.5 m from radar antennas\n\nRadar beams aligned perpendicular to the participant’s thorax\n\nSampling rate: 1 Hz for all radars\n\nRange resolution: 3.75 cm (77 GHz), 4.2 cm (60 GHz), 10 cm (24 GHz)\n\nData Acquisition Procedure:\n\nContinuous acquisition of raw I/Q radar signals during 5-minute sessions\n\nSimultaneous reference measurements collected from Masimo Rad-97 and respiratory belt\n\nAll participants instructed to remain seated and still\n\nSignal Processing & Validation:\n\n2D FFT applied to I/Q data to generate range profiles\n\nChest-wall range bin identified via peak detection\n\nPhase signal extracted and detrended\n\nRespiration filtered at 0.1–0.5 Hz (4th-order Butterworth)\n\nHeart rate filtered at 0.8–2.0 Hz with ensemble averaging over multiple bins\n\nInstantaneous RR and HR estimated via peak detection\n\nPerformance metrics: mean absolute error (MAE) and Pearson correlation coefficient (r) versus reference signals\n\nExpected metrics: 77 GHz MAE < 1 breath/min (RR), < 2 bpm (HR), r > 0.95 for both; 24 GHz slightly lower but operationally robust\n\nSafety & Feasibility:\n\nNon-contact, non-invasive monitoring\n\nParticipants seated in controlled laboratory conditions\n\nNo direct contact or radiation exposure risks beyond standard radar safety guidelines\n\nSystem feasible for short-term cardiopulmonary assessment across multiple radar frequencies", "three_class_category": "Signal & Sampling", "violated_constraint": "sensor_bandwidth", "violated_principle": "Sensor bandwidth mismatch", "why_invalid": "Nyquist-Shannon sampling theorem: the sampling rate must be at least twice the highest frequency of the signal to avoid aliasing. With a sampling rate of 1 Hz, the Nyquist frequency is 0.5 Hz, which is lower than the heart rate signal frequency range of 0.8–2.0 Hz, causing aliasing and making accurate heart rate measurement impossible. Fix: Increase the sampling rate to at least 4 Hz to cover the heart rate frequencies up to 2 Hz.", "minimal_fix": "Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.", "difficulty": "medium", "surface_plausibility": "high", "severity": "fatal", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000584", "source_id": "93b573fe8d29", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "minor_issue", "protocol": "Protocol: High-Density sEMG Acquisition for Hand Gesture Classification\nObjective: To acquire surface electromyography (sEMG) signals from the forearm for the classification of five distinct hand gestures (power grasp, key pinch, wrist extension, wrist flexion, and hand open).\nEquipment: 8-channel sEMG system (Bagnoli Desktop, Delsys Inc.), Ag/AgCl surface electrodes (inter-electrode distance: 10 mm), Motion capture system (OptiTrack) for ground-truth gesture labeling, Data acquisition unit sampling at 1000 Hz with a 16-bit ADC.\nSensor Placement & Configuration: Based on anatomical palpation, eight electrode pairs will be placed over the following muscles: Flexor Digitorum Superficialis, Extensor Digitorum Communis, Flexor Carpi Radialis, Extensor Carpi Radialis Longus, First Dorsal Interosseous, Abductor Pollicis Brevis, Flexor Pollicis Longus, and Extensor Pollicis Longus. A reference electrode will be placed on the olecranon. Electrode impedance will be checked prior to data collection and must be below 20 kΩ.\nData Acquisition Procedure: The participant's right forearm will be cleaned with isopropyl alcohol and lightly abraded to reduce skin impedance. Participants will be seated with their forearm supported. They will be prompted via visual cue to perform each of the five gestures, holding each for 5 seconds with a 3-second rest between trials. Each gesture will be repeated 10 times in a randomized block design. sEMG and motion capture data will be synchronized.\nSignal Processing & Validation: Raw sEMG data will be band-pass filtered (20–450 Hz), full-wave rectified, and normalized to the peak amplitude observed during a maximum voluntary contraction (MVC) task performed at the start of the session. Features (RMS, waveform length, mean frequency) will be extracted from 250 ms sliding windows with 50% overlap. A 70/30 train-test split will be used, stratified by participant. A Support Vector Machine (SVM) with a radial basis function kernel will be trained for gesture classification. Performance will be evaluated using accuracy, precision, and recall. Data trials with visible motion artifact will be excluded.\nSafety & Feasibility: Participants are ten healthy adults (5 male, 5 female), right-handed, with no history of neuromuscular disorders.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Suboptimal but physically feasible experimental design.", "why_invalid": "The protocol remains physically feasible, but 错误提示: 1. 10次手势重复不够 2. 数据集划分有误: 70/30混合划分无法展示模型泛化能力,应该使用80/20 LOSO. The setting is suboptimal because the sampling margin is small, leaving limited room for anti-aliasing filter transition bands and making near-cutoff components more vulnerable to distortion. It is not a fatal violation because the nominal sampling condition is still approximately satisfied.", "minimal_fix": "Increase the sampling rate or lower the effective analysis bandwidth to provide a safer anti-aliasing margin.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "错误提示:\n1. 10次手势重复不够\n2. 数据集划分有误: 70/30混合划分无法展示模型泛化能力,应该使用80/20 LOSO" }, { "id": "gold_0507_000586", "source_id": "b5e62808f32d", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "valid", "protocol": "Protocol: EEG-Based Motor Imagery Brain-Computer Interface System Validation\n\nObjective: To validate an EEG-BCI system for classifying left-hand vs. right-hand motor imagery using a hybrid sensor approach.\n\nEquipment: BioSemi ActiveTwo EEG amplifier with 24-bit ADC and 1000 Hz sampling rate. Electrodes include a 16-channel hybrid montage: 10 wet-gel Ag/AgCl electrodes (F3, Fz, F4, C3, Cz, C4, P3, Pz, P4, Oz) placed per the 10-20 system for high-fidelity cortical signal capture, 4 dry electrodes integrated into a headset for frontal (Fp1, Fp2) and temporal (T7, T8) monitoring, and 2 ear-EEG electrodes (left/right concha) for robust reference and artifact monitoring. Impedance requirements are wet electrodes < 5 kΩ and dry electrodes < 40 kΩ.\n\nSensor Placement & Configuration: 10 wet-gel Ag/AgCl electrodes are positioned at F3, Fz, F4, C3, Cz, C4, P3, Pz, P4, Oz according to the 10-20 system. 4 dry electrodes are placed at Fp1, Fp2, T7, T8 in a headset. 2 ear-EEG electrodes are located in the left and right concha.\n\nData Acquisition Procedure: The participant is seated comfortably and instructed to minimize motion. Each trial begins with a 2-second fixation cross, followed by a 1.5-second cue (arrow pointing left or right). The participant performs kinesthetic motor imagery of the corresponding hand for 4 seconds, followed by a 2-3 second randomized rest interval. A total of 100 trials (50 per class) are recorded per session.\n\nSignal Processing & Validation: Preprocessing includes band-pass filtering (1-40 Hz) and 50/60 Hz notch filtering, with Artifact Subspace Reconstruction (ASR) applied to remove transient high-amplitude artifacts. Feature extraction uses Common Spatial Patterns (CSP) on electrodes C3, C4, Cz, and adjacent electrodes to maximize discriminability of mu (8-12 Hz) and beta (13-30 Hz) event-related desynchronization/synchronization (ERD/ERS). Classification is performed using Linear Discriminant Analysis (LDA), validated with 10-fold cross-validation on the 100-trial dataset. Validation metrics include mean classification accuracy, Cohen's kappa, F1-score, information transfer rate (ITR), analysis of ear-EEG stability against wet electrode reference, and comparison of dry vs. wet electrode signal quality (SNR in target bands).\n\nSafety & Feasibility: The participant is seated comfortably and instructed to minimize motion to ensure safety and reduce artifacts during data acquisition.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000590", "source_id": "b5e62808f32d", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "valid", "protocol": "Protocol:\n\nEEG-Based Motor Imagery Brain-Computer Interface System Validation.\n\nObjective:\n\nTo validate a multi-modal EEG-BCI system for classifying left-hand vs. right-hand motor imagery using a combination of wet gel, dry, and ear-EEG electrodes, targeting sensorimotor rhythms in the mu/beta range of 8–30 Hz.\n\nEquipment:\n\nThe primary EEG cap uses 64-channel active wet gel Ag/AgCl electrodes, such as actiCHamp Plus. The supplementary dry EEG setup uses an 8-channel dry electrode headband, such as B-Alert X24. The ear-EEG setup uses 6-channel ear-mounted electrodes, such as cEEGrid.\n\nThe amplifier and ADC use 24-bit resolution with a sampling rate of 500 Hz. Impedance for wet gel electrodes will be maintained below 10 kΩ. A hardware bandpass filter from 0.1–100 Hz will be used.\n\nSensor Placement & Configuration:\n\nWet gel electrodes are placed according to the 10–20 system, focusing on central regions including C3, C4, Cz, CP3, and CP4. The dry electrode headband is placed over frontal and central areas. Ear-EEG electrodes are ear-mounted.\n\nConfiguration includes maintaining wet gel electrode impedance below 10 kΩ and using a hardware bandpass filter from 0.1–100 Hz.\n\nData Acquisition Procedure:\n\nThe participant is seated comfortably in a shielded room. The paradigm is a computer-cued motor imagery task. Each trial begins with a 2-second fixation cross, followed by an auditory or visual cue for left-hand or right-hand motor imagery for 4 seconds, and a 3–5 second rest period.\n\nA total of 100 trials per class will be recorded. All three sensor types, including wet cap, dry headband, and ear-EEG, will record concurrently from the same participant in a single session.\n\nSignal Processing & Validation:\n\nPreprocessing includes bandpass filtering from 1–40 Hz. Artifact Subspace Reconstruction is applied for transient artifact removal. Independent Component Analysis is used on wet gel data to remove ocular and muscular artifacts.\n\nFeature extraction includes computing the log-variance of bandpass-filtered signals in the 8–12 Hz and 13–30 Hz bands from relevant channels. Common Spatial Patterns are applied to wet and dry EEG data.\n\nClassification uses a Linear Discriminant Analysis classifier trained and evaluated with stratified 10-fold cross-validation on a per-subject basis. Model performance is quantified by classification accuracy, Cohen’s kappa, and Information Transfer Rate.\n\nValidation includes performance benchmarking by comparing classification accuracy across the three sensor modalities, including wet, dry, and ear-EEG, against a chance level of 50%. Physiological validation is performed by inspecting topographic maps of CSP filters and event-related desynchronization/synchronization patterns to confirm engagement of sensorimotor cortices.\n\nSafety & Feasibility:\n\nFeasibility assessment involves comparing setup time and signal stability between wet gel and dry/ear systems to evaluate practical BCI deployment scenarios.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000594", "source_id": "8bf07ce296af", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: sEMG-Based Hand Gesture Recognition System Validation\n\nObjective: To validate a surface electromyography (sEMG) system for robust classification of 5 distinct hand gestures.\n\nEquipment: 8-channel wet-gel Ag/AgCl electrodes (Ambu Neuroline 720) and 8-channel dry stainless steel electrodes (custom array). High-density (HD) array used in a separate session. Amplifier: 16-bit ADC, 1-1000 Hz bandpass, CMRR >100 dB (e.g., g.USBamp).\n\nSensor Placement & Configuration: Bipolar configuration over the dominant forearm. 8 channels targeting key muscle groups: Flexor Digitorum Superficialis (2), Extensor Digitorum (2), Flexor Carpi Ulnaris (1), Extensor Carpi Radialis (1), First Dorsal Interosseous (1), Abductor Pollicis Brevis (1). Inter-electrode distance: 20 mm. Reference electrode on the olecranon.\n\nData Acquisition Procedure: Skin preparation: abrade with alcohol, apply conductive gel for wet electrodes. Participant seated, forearm resting. Perform 5 gestures (power grasp, key pinch, wrist flexion, wrist extension, finger abduction). Each gesture: 5-second contraction at 50% MVC (monitored via dynamometer), 10-second rest. 10 repetitions per gesture. Sampling rate: 2000 Hz (sufficient for Nyquist criterion of 500 Hz EMG). Simultaneous recording from all electrode types in the same session for direct comparison.\n\nSignal Processing & Validation: Pre-processing: 20-450 Hz 4th-order Butterworth bandpass filter, 50/60 Hz notch filter, full-wave rectification. Segmentation: 250 ms sliding window, 50% overlap. Features: Time-domain (RMS, MAV, WL), Frequency-domain (MDF, MPF), and autoregressive coefficients (AR6). Classification: 70/30 train/test split, 5-fold cross-validation. Use LDA and SVM classifiers. Validation Metrics: Accuracy, F1-score, Confusion Matrix. Compare performance across electrode types.\n\nSafety & Feasibility: N=10 healthy adults (18-35 years). Obtain informed consent per institutional IRB. Screen for neuromuscular disorders. Monitor electrode impedance (<5 kΩ for wet, <20 kΩ for dry). Check for motion artifacts. Ensure consistent MVC levels.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000596", "source_id": "8bf07ce296af", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: Multi-Sensor sEMG Gesture Recognition System Validation\n\nObjective: To acquire and classify surface electromyography (sEMG) signals from forearm muscles for a set of 8 predefined hand gestures, utilizing and comparing three sensor modalities: wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and a high-density electrode array.\n\nEquipment: A 24-bit ADC bioamplifier with a sampling rate of 2000 Hz per channel, bandpass filter (20-500 Hz), and a programmable gain of 1000, with CMRR > 100 dB. Wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and a 16-channel dry electrode array. A force transducer for gesture onset reference.\n\nSensor Placement & Configuration: Config A uses 8 Ag/AgCl electrodes with conductive gel in a bipolar configuration over the 4 major forearm muscle groups (flexor digitorum superficialis, extensor digitorum, flexor carpi ulnaris, extensor carpi radialis longus), with a common reference electrode on the olecranon. Config B uses 8 dry stainless steel electrodes in an identical anatomical arrangement as Config A. Config C uses a 16-channel dry electrode array (4x4 grid, 10mm inter-electrode distance) placed circumferentially around the forearm's maximum girth.\n\nData Acquisition Procedure: 5 healthy participants perform 10 repetitions of each of 8 predefined hand gestures (e.g., fist, wrist flexion, index extension) with a 3-second hold and 2-second rest. A force transducer provides a concurrent reference signal for gesture onset.\n\nSignal Processing & Validation: Pre-processing includes a notch filter at 50/60 Hz and segmentation into 250 ms windows with 50% overlap. Feature extraction involves time-domain (RMS, Waveform Length, Zero Crossings) and frequency-domain (Mean Power Frequency) features from each channel. Validation uses a 5-fold cross-validation scheme stratified per participant. A Support Vector Machine (SVM) classifier is trained and tested. Performance is evaluated using accuracy, F1-score, and confusion matrices. Statistical analysis with ANOVA compares classification accuracy across the three sensor configurations to determine the effect of sensor type on recognition performance.\n\nSafety & Feasibility: The protocol uses commercially available, low-risk equipment. Skin preparation with abrasive gel for wet electrodes minimizes impedance. Dry electrode pressure is standardized. All procedures are approved by an institutional review board, with informed consent obtained.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000597", "source_id": "8bf07ce296af", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: High-Density sEMG Acquisition for Hand Gesture Recognition\n\nObjective: To acquire and validate surface electromyography (sEMG) signals for the classification of six distinct hand gestures using a multi-modal electrode array.\n\nEquipment: The sEMG system is a commercial 32-channel sEMG amplifier (e.g., Delsys Trigno, Bagnoli) with a sampling rate of 2000 Hz per channel and 16-bit ADC resolution. The electrodes include a hybrid array comprising: a) 16 wet-gel Ag/AgCl electrodes for high-fidelity reference, b) 8 dry stainless steel electrodes for rapid application, and c) an 8-channel high-density dry electrode array with an inter-electrode distance of 8mm for spatial mapping. The reference electrode is a wet-gel Ag/AgCl electrode placed over the lateral epicondyle of the elbow. The ground is a wet-gel electrode placed over the acromion process. A monitor is positioned in front of the subject displaying real-time sEMG envelopes and gesture cues.\n\nSensor Placement & Configuration: The forearm skin will be cleaned with abrasive gel and alcohol. Electrodes will be placed over the primary muscles for wrist/hand function: Flexor Digitorum Superficialis (FDS), Extensor Digitorum Communis (EDC), Flexor Carpi Ulnaris (FCU), Extensor Carpi Radialis (ECR), First Dorsal Interosseous (FDI), and Abductor Pollicis Brevis (APB). Wet-gel electrodes will be placed in a bipolar configuration with 20mm inter-electrode distance over the muscle belly. The high-density array will be centered over the EDC and ECR complex. Electrode-skin impedance will be verified to be <10 kΩ at 30 Hz for wet-gel electrodes.\n\nData Acquisition Procedure: The subject will perform six gestures (rest, fist, wrist flexion/extension, key grip, fine pinch) in a randomized block design. Each trial consists of a 2-second rest, a 5-second maximal voluntary contraction (MVC) hold, and a 2-second recovery. A 30-second rest will be provided between blocks. Three repetitions of each gesture will be recorded per block.\n\nSignal Processing & Validation: Raw sEMG data will be band-pass filtered (20-500 Hz, 4th-order Butterworth) and notch-filtered (50/60 Hz). Signal quality will be validated by calculating the Signal-to-Noise Ratio (SNR) during MVC holds, targeting >20 dB for wet-gel electrodes. For gesture recognition validation, a 100ms sliding window with 50% overlap will extract time-domain features (RMS, waveform length). A linear discriminant analysis (LDA) classifier will be trained on 70% of the data (stratified by gesture) and tested on the remaining 30%. Performance will be reported as classification accuracy, with a target of >95% for the wet-gel configuration.\n\nSafety & Feasibility:", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000598", "source_id": "8bf07ce296af", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: Comparative Evaluation of sEMG Electrode Systems for Hand Gesture Recognition\nObjective: To assess the performance of wet gel Ag/AgCl, dry stainless steel, and high-density electrode arrays for classifying five hand gestures using surface electromyography (sEMG).\nEquipment: Bagnoli desktop system with wet gel Ag/AgCl electrodes; Delsys Trigno Avanti system with dry stainless steel sensors; g.tec g.SCARABEO 32-channel high-density array.\nSensor Placement & Configuration: For the Bagnoli and Delsys systems, a bipolar configuration will be used over six forearm muscles: flexor digitorum superficialis, extensor digitorum, flexor carpi radialis, extensor carpi radialis longus, pronator teres, and brachioradialis, with a reference electrode on the olecranon. For the g.tec system, the 8x4 array will be placed over the forearm flexor compartment.\nData Acquisition Procedure: Skin preparation involves cleaning with abrasive gel and alcohol for all conditions. Participants will perform five gestures (power grasp, key pinch, wrist extension, wrist flexion, finger abduction) plus rest, with 5-second contractions and 10-second rest intervals. Each gesture block is repeated 10 times per electrode system, with system order randomized across participants. Signal acquisition uses sampling at 2000 Hz, 16-bit ADC, and a hardware bandpass filter of 20-500 Hz.\nSignal Processing & Validation: Preprocessing includes bandpass filtering (20-450 Hz, 4th order Butterworth), notch filtering (50/60 Hz), and full-wave rectification. Feature extraction computes time-domain (RMS, waveform length, zero crossings) and frequency-domain (median frequency, mean power) features over 200ms sliding windows. Classification uses a Support Vector Machine (SVM) with a radial basis function kernel, trained and evaluated with 10-fold cross-validation on the 10 repetitions, reporting accuracy, F1-score, and confusion matrices. Statistical analysis employs repeated-measures ANOVA to compare classification accuracy across electrode systems (α=0.05), with the within-subject design controlling for inter-subject variability.\nSafety & Feasibility: Participants are 10 healthy adults (5 male, 5 female) with no history of upper limb neuromuscular disorders. Skin preparation is performed to ensure signal quality. The within-subject design directly compares system performance under standardized conditions, enhancing feasibility and controlling for variability.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000599", "source_id": "bb4c993bd534", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "minor_issue", "protocol": "Protocol: Non-Contact Vital Sign Monitoring Using FMCW Millimeter-Wave Radar\n\nObjective: To develop a standardized protocol for extracting respiration rate (RR) and heart rate (HR) from human subjects using a frequency-modulated continuous wave (FMCW) radar operating in the 60-GHz band, and to validate the measurements against a clinical-grade ECG and respiration belt.\n\nEquipment: 60-GHz FMCW radar sensor (e.g., Texas Instruments IWR1443BOOST), Clinical 3-lead ECG system, Chest-mounted piezoelectric respiration belt, Data acquisition computer with MATLAB, Metronome.\n\nSensor Placement & Configuration: The radar sensor will be mounted on a stable tripod at a height of 1.2 meters, aimed at the subject's thorax from a distance of 0.5 meters. The radar is configured with a chirp bandwidth of 4 GHz, providing a range resolution of ~3.75 cm. The frame rate is set to 5 Hz to minimize data throughput and computational load. The subject will be seated in a chair, remaining still, with the ECG electrodes and respiration belt applied.\n\nData Acquisition Procedure: Baseline Recording (5 min): The subject breathes normally. Radar, ECG, and belt data are recorded simultaneously. Controlled Breathing (5 min): The subject follows a metronome set to 12 breaths per minute (0.2 Hz). Post-Exercise Recovery (5 min): After 30 seconds of light jogging in place, the subject sits and data is recorded during recovery.\n\nSignal Processing & Validation: Radar data will be processed using a range-bin selection algorithm to identify the thorax pixel. Vital signs will be extracted via Fast Fourier Transform (FFT) spectrum analysis of the phase signal from the selected range bin. RR and HR will be identified as dominant peaks in the respective frequency bands (0.1-0.5 Hz for respiration, 0.8-2.0 Hz for heart). Accuracy will be assessed by comparing radar-derived RR and HR to the reference sensors using Bland-Altman analysis and correlation coefficients.\n\nSafety & Feasibility:", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Suboptimal but physically feasible experimental design.", "why_invalid": "The protocol remains physically feasible, but 错误原因:5Hz的采样率对于2Hz的心跳来说只预留了1Hz的采样率空间,因此在实际工程应用时非最优. The setting is suboptimal because the sampling margin is small, leaving limited room for anti-aliasing filter transition bands and making near-cutoff components more vulnerable to distortion. It is not a fatal violation because the nominal sampling condition is still approximately satisfied.", "minimal_fix": "Increase the sampling rate or lower the effective analysis bandwidth to provide a safer anti-aliasing margin.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "错误原因:5Hz的采样率对于2Hz的心跳来说只预留了1Hz的采样率空间,因此在实际工程应用时非最优" }, { "id": "gold_0507_000604", "source_id": "b5e62808f32d", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "valid", "protocol": "Protocol: EEG-Based BCI for Motor Imagery Classification\nObjective: To acquire and classify EEG signals during motor imagery tasks to validate a hybrid BCI system using wet gel, dry, and ear-EEG electrodes.\nEquipment: The EEG system is a 64-channel research-grade amplifier with 24-bit ADC and a sampling rate of 1000 Hz (within 250-1000 Hz range). Electrodes include wet gel: 32 Ag/AgCl electrodes placed according to the extended 10-20 system (focus on C3, Cz, C4, and surrounding motor cortex areas); dry: 8 spring-loaded dry electrodes placed over frontal (Fp1, Fp2) and supplementary motor areas for comparison; and ear-EEG: 6 electrodes embedded in custom ear molds targeting the cymba conchae for P300 and alpha-band monitoring. Ground is at AFz; online reference to linked mastoids (TP9, TP10).\nSensor Placement & Configuration: Wet electrodes are applied with conductive gel to achieve impedance <5 kΩ. Dry and ear electrodes are adjusted for stable contact. Wet electrodes follow the extended 10-20 system with focus on motor cortex areas; dry electrodes are over frontal and supplementary motor areas; ear-EEG electrodes target the cymba conchae.\nData Acquisition Procedure: Participants are N=20 healthy adults, seated comfortably. The experimental task is a two-session design. Session 1 (Motor Imagery): Visual cue-guided trials of kinesthetic left hand, right hand, and feet motor imagery (MI). Each trial consists of 2s fixation, 4s MI, 2s rest, with 50 trials per class. Session 2 (P300): Standard visual oddball paradigm with frequent non-target vs. rare target stimuli to elicit P300 potentials. Data acquisition involves recording continuous EEG at 1000 Hz.\nSignal Processing & Validation: Preprocessing includes band-pass filtering at 1-40 Hz for MI or 0.1-20 Hz for P300, performing Independent Component Analysis (ICA) to remove ocular and muscular artifacts, and re-referencing to common average. Feature extraction for motor imagery uses Common Spatial Patterns (CSP) applied to 8-30 Hz (mu+beta) filtered data from wet/dry electrodes and Power Spectral Density (PSD) in alpha (8-13 Hz) and beta (13-30 Hz) bands. For P300, features are Event-Related Potentials (ERPs) time-locked to stimuli, focusing on N200-P300 complex from ear-EEG and central electrodes. Classification for MI uses Linear Discriminant Analysis (LDA) or Support Vector Machine (SVM), and for P300 uses stepwise linear discriminant analysis (SWLDA). Validation involves 10-fold cross-validation on 70% training data, reporting accuracy, precision, and recall on 30% held-out test set, with statistical significance assessed via repeated-measures ANOVA comparing electrode types.\nSafety & Feasibility: Participants are healthy adults with electrode impedance checks to ensure signal quality. The expected output is validated classification accuracy for MI (>70% chance level) and P300 (>90%) across sensor modalities, demonstrating system feasibility.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000623", "source_id": "a677f056b289", "domain": "radar_vital_signs", "scenario": "radar_vital_signs", "label": "minor_issue", "protocol": "Protocol:\n\nNon-Contact Monitoring of Heart Rate and Respiration using FMCW Millimeter-Wave Radar.\n\nObjective:\n\nTo extract and validate heart rate and respiration rate signals from human subjects using a frequency-modulated continuous wave radar operating in the 60 GHz band.\n\nEquipment:\n\nThe equipment includes a 60 GHz FMCW radar sensor module, such as Infineon BGT60TR13C, and a data acquisition system with a sampling rate of 1 kHz for the baseband I/Q signals.\n\nReference devices include a Polar H10 chest strap for heart rate and a nasal thermistor for respiration rate. An adjustable radar mount and a standard office chair will also be used.\n\nSensor Placement & Configuration:\n\nThe radar will be placed on a table, 1 meter directly in front of the seated subject, aimed at the mid-sternum. The environment will be a quiet, enclosed room to minimize multipath interference.\n\nThe radar’s chirp bandwidth will be configured to 2.5 GHz, providing a theoretical range resolution of approximately 6 cm, which is sufficient to coarsely separate the subject’s torso from the chair back. The radar will be focused on a single range bin corresponding to the subject’s thorax. Reference sensors will be applied to the subject, and a 5-minute acclimatization period will be observed.\n\nData Acquisition Procedure:\n\nFor each of 15 healthy adult subjects aged 20–40, three 2-minute recordings will be collected: at rest, during light physical activity such as arm movements, and during paced breathing at 15 breaths per minute.\n\nThe radar’s I/Q data and the reference signals will be recorded simultaneously.\n\nSignal Processing & Validation:\n\nThe radar signal will undergo range-FFT to isolate the target bin. Phase extraction will be performed, followed by bandpass filtering with 0.1–0.5 Hz for respiration rate and 0.8–2.0 Hz for heart rate.\n\nHeart rate and respiration rate will be estimated via peak detection in the frequency domain. Agreement with reference devices will be assessed using Bland-Altman analysis and Pearson correlation.\n\nSafety & Feasibility:\n\nThe experiment will be conducted in a quiet, enclosed room. A 5-minute acclimatization period will be observed before recording. The setup uses non-contact 60 GHz FMCW radar placed 1 meter in front of the seated subject, with reference sensors applied to the subject for simultaneous heart rate and respiration rate recording.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Suboptimal but physically feasible experimental design.", "why_invalid": "The setting is suboptimal because the sampling margin is small, leaving limited room for anti-aliasing filter transition bands and making near-cutoff components more vulnerable to distortion. It is not a fatal violation because the nominal sampling condition is still approximately satisfied.", "minimal_fix": "Increase the sampling rate or lower the effective analysis bandwidth to provide a safer anti-aliasing margin.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "Minor Issue: The configured chirp bandwidth of 2.5 GHz, while functional, is suboptimal for this application. A bandwidth of 4-5 GHz would provide superior range resolution (~3.75 cm), enabling more precise spatial focusing solely on the moving thorax and better rejection of static clutter from the chair and other nearby objects. The current configuration may allow some residual clutter into the vital sign range bin, potentially reducing signal-to-noise ratio and the accuracy of the phase-derived vital signs, especially during the movement condition.\n不要出现数据泄露" }, { "id": "gold_0507_000628", "source_id": "90592483921e", "domain": "PPG_BP", "scenario": "PPG_BP", "label": "minor_issue", "protocol": "Protocol:\n\nContinuous Blood Pressure Estimation via Wrist-Worn PPG and ECG.\n\nObjective:\n\nTo develop and validate a wearable system for continuous, cuff-less blood pressure estimation using photoplethysmography and electrocardiography signals derived from a single wrist-worn device.\n\nEquipment:\n\nThe system uses a wrist-worn sensor module with integrated PPG and dry-contact ECG electrodes. The PPG sensor uses a green LED at 525 nm. The ECG component uses dry-contact electrodes for single-lead ECG acquisition.\n\nA reference blood pressure monitor using the auscultatory method will be used for calibration and validation. The data acquisition system will sample both PPG and ECG signals at 125 Hz. The study will involve healthy adult volunteers, with n=15 participants.\n\nSensor Placement & Configuration:\n\nThe wrist-worn device will be secured on the subject’s left wrist. The PPG sensor will be placed over the radial artery. The ECG electrodes will be positioned for a single-lead Lead I configuration.\n\nBefore recording, the skin will be cleaned with alcohol wipes as part of participant preparation.\n\nData Acquisition Procedure:\n\nParticipants will rest in a seated position for 10 minutes. After a 5-minute stabilization period, three sequential brachial blood pressure measurements will be taken using the reference monitor. The average of these readings will be used to calibrate the initial model parameters for each subject.\n\nContinuous PPG and ECG data will then be recorded for 30 minutes. During the recording period, reference blood pressure will be measured every 5 minutes, yielding a total of 6 reference points. PPG, ECG, and reference blood pressure measurements will be temporally aligned for calibration and validation.\n\nSignal Processing & Validation:\n\nPulse transit time will be calculated as the time delay between the ECG R-peak and the PPG systolic peak. A regression model will be trained using the calibration data to map PTT to systolic and diastolic blood pressure.\n\nThe calibrated algorithm will generate a continuous blood pressure waveform. Its accuracy will be assessed by comparing the algorithm’s estimated blood pressure values at the timestamps of the reference measurements. Performance will be evaluated using mean error and standard deviation against the reference.\n\nSafety & Feasibility:\n\nThe protocol involves healthy adult volunteers. Participants will rest in a seated position before and during data acquisition. Skin will be cleaned with alcohol wipes for preparation. No additional safety or feasibility details are specified.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Signal resolution for precise PTT measurement", "why_invalid": "The 125 Hz sampling rate is physically sufficient for capturing PPG and ECG signals, but it provides only a minimal margin above the Nyquist limit. This suboptimal choice could reduce temporal precision in detecting PPG systolic peaks, leading to slight jitter in pulse transit time and potentially lower BP estimation accuracy during rapid hemodynamic changes. It is not fatal because the experiment can still proceed and yield usable data.", "minimal_fix": "Increase the sampling rate to at least 250 Hz to improve temporal resolution of PPG and ECG signals, ensuring more precise detection of systolic peaks for pulse transit time calculation, while remaining within the capabilities of the wrist-worn device.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "Minor Suboptimal Issue: The protocol specifies a sampling rate of 125 Hz for both signals. While this exceeds the Nyquist frequency for typical PPG/ECG waveforms (~1-35 Hz), it provides a minimal margin. This could limit the precision of detecting the exact PPG systolic peak for PTT calculation, potentially introducing slight jitter and reducing the accuracy of the derived BP estimates, especially during periods of rapid hemodynamic change.\n不要出现数据泄露" }, { "id": "gold_0507_000631", "source_id": "0f4e0eade5cc", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "minor_issue", "protocol": "Protocol: EEG-Based Motor Imagery Classification for Brain-Computer Interface\n\nObjective: To classify left-hand vs. right-hand motor imagery (MI) from EEG signals using common spatial patterns (CSP) and linear discriminant analysis (LDA).\n\nEquipment: 32-channel active electrode system (e.g., g.tec g.USBamp).\n\nSensor Placement & Configuration: International 10-20 system montage. Ground electrode placed at AFz, reference at left mastoid. All electrode impedances kept below 10 kΩ.\n\nData Acquisition Procedure: Sampling rate 256 Hz. Hardware band-pass filter from 0.5 to 100 Hz applied. Experimental paradigm: each trial begins with a fixation cross for 2 seconds, followed by an auditory cue indicating left or right hand motor imagery. Participants perform kinesthetic motor imagery for 4 seconds. Rest period of 3-5 seconds (randomized) separates trials. Total of 200 trials (100 per class).\n\nSignal Processing & Validation: Offline band-pass filtering between 8-30 Hz (mu and beta bands). Artifacts rejected via thresholding (±100 µV) and manual inspection. Feature extraction: 4-second motor imagery window extracted. Common Spatial Patterns (CSP) applied to data from electrodes C3, Cz, C4, and CPz to maximize variance between classes. Log-variance of first and last two CSP components forms feature vector. Linear Discriminant Analysis (LDA) classifier used. Validation: dataset split into 80% training (160 trials) and 20% testing (40 trials) using single random permutation; cross-validation not performed. Performance metric: classification accuracy on test set reported. Analysis: mean classification accuracy across all participants calculated.\n\nSafety & Feasibility: Ten healthy, right-handed volunteers aged 20-30 with no history of neurological disorders.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Signal sampling and validation robustness", "why_invalid": "The protocol uses a 256 Hz sampling rate and a simple 80/20 train-test split without cross-validation. While physically sufficient to capture EEG motor imagery signals, the limited Nyquist margin and absence of cross-validation make the experimental design suboptimal for reliably estimating classifier performance. It is not fatal because data can still be collected and classification performed, but results may be slightly less robust and generalizable.", "minimal_fix": "Increase the sampling rate to at least 512 Hz to provide a larger Nyquist margin for capturing high-frequency EEG components, and implement k-fold cross-validation (e.g., 5-fold) on the training set to improve the reliability and generalizability of classification performance estimates.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "1. 预留的Nyquist 冗余不够\n2. 数据划分不理想,没有交叉验证" }, { "id": "gold_0507_000633", "source_id": "0b0cc2597b1a", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "minor_issue", "protocol": "Protocol: Surface Electromyography for Hand Gesture Recognition\n\nObjective: To collect surface electromyography (sEMG) data from forearm muscles for the classification of eight static hand gestures.\n\nEquipment: 8-channel sEMG system with active electrodes, Ag/AgCl electrodes, abrasive skin preparation gel, elastic bandage for electrode fixation, data acquisition software.\n\nSensor Placement & Configuration: The participant will be seated comfortably with their forearm resting on a support, elbow at 90 degrees. The skin on the participant's right forearm will be cleaned with alcohol and lightly abraded with gel to reduce impedance. Eight active electrodes will be placed on the skin overlying the flexor digitorum superficialis, extensor digitorum, flexor carpi ulnaris, extensor carpi radialis, and intrinsic hand muscles (4 electrodes), following SENIAM guidelines for muscle belly location. A single reference electrode will be placed over the ulnar styloid process. Electrode impedance will be confirmed to be below 20 kΩ. The sEMG system will be configured with a bandpass filter of 20-450 Hz and a sampling rate of 500 Hz. Signals will be monitored in real-time for noise and motion artifacts.\n\nData Acquisition Procedure: The participant will be instructed to perform each of the eight gestures (e.g., fist, wrist extension, finger pinch, etc.) following a visual cue on a monitor. For each gesture, the participant will hold the contraction at a comfortable, sub-maximal force for 5 seconds, followed by 10 seconds of rest. Each gesture will be repeated 10 times, resulting in a total of 80 trials. The order of gesture presentation will be randomized. Raw sEMG data will be recorded for the full duration of each 5-second contraction. Data will be stored for offline processing and classification analysis.\n\nSignal Processing & Validation: Data will be stored for offline processing and classification analysis.\n\nSafety & Feasibility: Skin cleaning and abrading with gel to reduce impedance, electrode impedance confirmed below 20 kΩ, elastic bandage for electrode fixation, and real-time monitoring for noise and motion artifacts to ensure data quality.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Signal sampling resolution", "why_invalid": "The protocol uses a 500 Hz sampling rate for sEMG signals, which is physically sufficient to capture the relevant muscle activity. However, it is suboptimal because a slightly higher sampling rate could provide better temporal resolution for capturing rapid muscle activations, improving feature extraction precision. It is not fatal as the experiment can still be conducted and meaningful data collected.", "minimal_fix": "Increase the sampling rate to 1000 Hz to improve temporal resolution and capture faster sEMG signal dynamics more accurately, while remaining within the capabilities of the acquisition system.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "错误原因:采样率非最优" }, { "id": "gold_0507_000639", "source_id": "b5e62808f32d", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "valid", "protocol": "Protocol: Protocol for EEG-Based Brain-Computer Interface Motor Imagery Classification\n\nObjective: To develop and validate an EEG-based BCI system for classifying left-hand versus right-hand motor imagery using mu (8–12 Hz) and beta (13–30 Hz) rhythms, with optional integration of P300 for hybrid validation.\n\nEquipment: Use a 32-channel EEG system (e.g., g.tec g.USBamp) with 16-bit ADC resolution and a sampling rate of 500 Hz. Electrodes include wet gel Ag/AgCl electrodes for primary placement, dry electrodes (e.g., Cognionics) for supplementary frontal/occipital monitoring, and ear-EEG electrodes (e.g., cEEGrid) for peripheral alpha monitoring. Maintain electrode-skin impedance below 5 kΩ for wet electrodes and below 20 kΩ for dry electrodes.\n\nSensor Placement & Configuration: Electrodes are placed according to the 10–20 system at positions Fz, C3, C4, Cz, P3, P4, O1, O2 to capture sensorimotor rhythms. Wet electrodes are used for primary placement, dry electrodes for supplementary monitoring, and ear-EEG electrodes for peripheral alpha monitoring. Configuration includes maintaining impedance below specified thresholds for each electrode type.\n\nData Acquisition Procedure: Instruct participants to sit comfortably, minimize muscle artifacts, and perform motor imagery tasks (e.g., imagining clenching left or right hand) without physical movement. Conduct a 5-minute resting-state baseline recording for noise characterization. Each trial consists of a 4-second visual cue (arrow indicating left or right imagery), followed by a 6-second imagery period, and a 2-second rest. Perform 100 trials per class (left/right) per session in randomized order, including 20 P300 trials using an auditory oddball paradigm for hybrid BCI validation. Record continuous EEG at 500 Hz with an anti-aliasing filter (0.1–100 Hz) and synchronize stimuli and EEG via Lab Streaming Layer (LSL).\n\nSignal Processing & Validation: Apply preprocessing with a bandpass filter (1–40 Hz), notch filter (50/60 Hz), and artifact rejection using independent component analysis (ICA) for eye/muscle artifacts. Extract features using common spatial patterns (CSP) for mu/beta bands and time-locked averaging for P300 amplitude. Classify using linear discriminant analysis (LDA) or support vector machine (SVM) with 10-fold cross-validation. Evaluate classification accuracy, sensitivity, specificity, and F1-score. Compare performance across electrode types (wet vs. dry vs. ear-EEG) using ANOVA. Ensure physical feasibility by monitoring system noise (SNR > 10 dB) and real-time latency (< 100 ms).\n\nSafety & Feasibility: Adjust parameters based on individual subject variability. Ensure compliance with ethical guidelines for human subjects research. Monitor system noise and latency to maintain feasibility during real-time operation.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" }, { "id": "gold_0507_000644", "source_id": "070be4101af3", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "minor_issue", "protocol": "Protocol: IMU-Based Motion Capture for Gait Analysis\nObjective: To collect lower-limb kinematic data using inertial measurement units (IMUs) for the purpose of training a gait phase classification algorithm.\nEquipment: 5x commercial-grade IMUs (Xsens MTw), 3-axis accelerometer and gyroscope. Elastic straps and medical tape. Motion capture lab with a 10-meter walkway. Synchronization hub and data acquisition laptop.\nSensor Placement & Configuration: Five IMUs will be attached to the participant: one on each foot (dorsal side), one on each shank (anterior, midway between malleoli and tibial plateau), and one on the pelvis (sacrum). Sensors will be secured using elastic straps and reinforced with medical tape over the participant’s clothing (e.g., athletic shorts and t-shirt).\nData Acquisition Procedure: Participants will be instructed to walk at a self-selected comfortable pace along the walkway. Each trial consists of 10 consecutive gait cycles. A total of 20 trials will be collected, with a 30-second rest between trials. IMU data (accelerometer and gyroscope) will be sampled at 100 Hz.\nSignal Processing & Validation: Raw sensor data will be processed using a standard sensor fusion algorithm (Madgwick filter) to estimate orientation. Gait events (heel strike, toe-off) will be detected using a peak-detection algorithm applied to the shank angular velocity. Features extracted from the sensor data will be used to train a random forest classifier.\nSafety & Feasibility: While securing sensors directly to the skin is ideal for minimizing motion artifact, this protocol uses attachment over clothing for practical reasons and participant comfort. This may introduce minor relative motion between the sensor and the underlying bony landmark, particularly in the shank placement, potentially adding a low-amplitude noise component to the gyroscope signals during dynamic movements. This effect is considered acceptable for the initial algorithm development phase.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "IMU sampling rate relative to signal frequency", "why_invalid": "Sampling the IMUs at 100 Hz is physically feasible for capturing lower-limb kinematics, but the Nyquist margin is minimal, providing limited redundancy for higher-frequency gait dynamics. This suboptimal setting could slightly reduce the accuracy of detecting rapid events such as heel strike and toe-off. It is not fatal because the main gait cycles are still captured adequately for algorithm development.", "minimal_fix": "Increase the IMU sampling rate to at least 200 Hz to provide greater Nyquist redundancy, improving temporal resolution and the precision of event detection in dynamic gait analysis.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "错误原因:预留的Nyquist冗余不够" }, { "id": "gold_0507_000657", "source_id": "0373d749e2a6", "domain": "EEG_BCI", "scenario": "EEG_BCI", "label": "minor_issue", "protocol": "Protocol: EEG-Based Motor Imagery Classification for BCI\n\nObjective: To collect and classify EEG signals during motor imagery tasks for a brain-computer interface, distinguishing between left-hand and right-hand imagination.\n\nEquipment: 32-channel EEG system (e.g., g.tec g.USBamp), Active electrodes in a 10-20 system montage, Conductive gel and abrasive skin prep, BCI2000 software for stimulus presentation and data recording\n\nSensor Placement & Configuration: Participants will be seated in a comfortable chair. The EEG cap will be fitted, and electrode impedances will be reduced using gel and gentle abrasion until all channels are below 20 kΩ.\n\nData Acquisition Procedure: A cue-based motor imagery task will be used. Each trial begins with a fixation cross (2s), followed by a random visual cue (arrow pointing left or right, 1.25s) instructing the participant to imagine sustained movement of the corresponding hand. The imagery period lasts 4s, followed by a rest period (2-3s). EEG data will be recorded at a sampling rate of 256 Hz with a bandpass filter of 0.1-100 Hz. A common average reference will be applied online. Each session will consist of 100 trials (50 per class), with short breaks every 25 trials.\n\nSignal Processing & Validation: Offline, data will be bandpass filtered (8-30 Hz, covering mu and beta rhythms). Features will be extracted using Common Spatial Patterns (CSP). A Linear Discriminant Analysis (LDA) classifier will be trained and evaluated using 10-fold cross-validation on the trial epochs.\n\nSafety & Feasibility: Not specified in the protocol.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "Electrode impedance and EEG signal fidelity", "why_invalid": "Maintaining electrode impedance below 20 kΩ is physically feasible and allows for interpretable EEG recordings in the mu and beta bands. However, this is suboptimal compared to the ideal <5 kΩ threshold, as higher impedance can introduce noise and reduce signal-to-noise ratio, particularly in higher-frequency components. It is not fatal because the primary task of broad-band classification remains achievable.", "minimal_fix": "Reduce electrode impedance to below 5 kΩ using additional conductive gel and skin preparation to improve signal-to-noise ratio and ensure higher fidelity for high-frequency EEG components.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "Note on Data Quality: The specified impedance threshold of 20 kΩ is higher than the ideal <5 kΩ standard, which may increase noise and reduce signal-to-noise ratio, particularly for high-frequency components. However, the signal should remain interpretable for the primary task of broad mu/beta band classification.\n不要出现数据泄露" }, { "id": "gold_0507_000662", "source_id": "1a938b312419", "domain": "IMU_motion", "scenario": "IMU_motion", "label": "minor_issue", "protocol": "Protocol: IMU-Based Motion Capture for Upper-Limb Activity Recognition\n\nObjective: To collect and classify upper-limb daily activities using a single inertial measurement unit (IMU) and a supervised machine learning model.\n\nEquipment: One commercial 9-axis IMU (accelerometer, gyroscope, magnetometer) with Bluetooth connectivity; adjustable elastic straps for sensor attachment; laptop with data acquisition software; synchronization trigger (e.g., LED flash or audible beep).\n\nSensor Placement & Configuration: The IMU will be securely fastened to the dorsal side of the participant's non-dominant wrist using an elastic strap. This location was chosen for comfort and to minimize interference with common tasks. The IMU will be calibrated according to the manufacturer's specifications prior to each session to correct for sensor biases.\n\nData Acquisition Procedure: The participant will be briefed and will provide informed consent. They will perform a brief range-of-motion warm-up. The participant will be seated and will perform a predefined sequence of 10 common activities (e.g., drinking from a cup, typing on a keyboard, opening a door, brushing hair) in a controlled lab environment. Each activity will be performed for 30 seconds, followed by a 10-second rest. The start of each activity trial will be marked in the data stream via the synchronization trigger, initiated simultaneously with a verbal command to the participant. IMU data (acceleration, angular velocity, magnetic field) will be streamed and logged at a sampling rate of 50 Hz.\n\nSignal Processing & Validation: Raw sensor data will be segmented into 5-second windows with a 50% overlap. A set of time-domain and frequency-domain features (e.g., mean, variance, FFT peaks) will be extracted from each window. A supervised classifier (e.g., Random Forest or Support Vector Machine) will be trained using a 70/30 train-test split to recognize the activities. Classification performance will be evaluated using accuracy, precision, and recall.\n\nSafety & Feasibility: The IMU placement on the non-dominant wrist was chosen for comfort and to minimize interference with common tasks. Participants are briefed and provide informed consent prior to data collection.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "IMU sampling rate and high-frequency motion capture", "why_invalid": "Streaming IMU data at 50 Hz is physically feasible and sufficient for capturing gross upper-limb movements, but the minimal Nyquist margin may underrepresent higher-frequency components during rapid movements, limiting temporal resolution. This setup is not fatal because the primary activities are still captured adequately for classifier training.", "minimal_fix": "Increase the IMU sampling rate to at least 100 Hz to provide additional Nyquist redundancy, improving temporal resolution and ensuring more accurate capture of rapid upper-limb motions.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "1. 预留的Nyquist冗余不足\n2." }, { "id": "gold_0507_000666", "source_id": "d8af83210f18", "domain": "throat_mic_speech", "scenario": "throat_mic_speech", "label": "minor_issue", "protocol": "Protocol:\n\nSilent Speech Recognition Using Throat Microphone and IMU.\n\nObjective:\n\nTo collect a dataset of silent speech articulations using a throat microphone and inertial measurement unit for the development of a silent speech interface.\n\nEquipment:\n\nThe system includes an accelerometer-based throat microphone with a frequency response of 20–2000 Hz. A 9-axis IMU with accelerometer, gyroscope, and magnetometer channels will be used to capture movement-related signals.\n\nA data acquisition system will record all sensors at a sampling rate of 2 kHz. An adjustable elastic neck band will be used to secure the throat microphone.\n\nSensor Placement & Configuration:\n\nThe participant will be seated comfortably in a quiet room. The throat microphone will be positioned over the larynx using the adjustable neck band.\n\nThe IMU will be adhered to the participant’s jaw, on the skin overlying the mandibular angle, using medical tape. This placement is chosen to capture the kinematic movements of the jaw during articulation.\n\nData Acquisition Procedure:\n\nThe system will be calibrated with a 5-second recording of silence. The participant will be instructed to silently articulate a predefined set of 20 phonetically balanced words, such as “pat,” “kite,” and “ship,” three times each.\n\nParticipants will be asked to minimize head movement and to perform the articulations at a natural, silent pace. Each silent articulation will be cued by a visual prompt on a screen. A 2-second recording window will be captured per trial, with a 1-second inter-trial interval.\n\nThe entire session will be repeated for 5 participants.\n\nSignal Processing & Validation:\n\nRaw sensor data will be segmented into 2-second windows. Features will be extracted from each window, including MFCCs from the throat microphone and motion magnitude from the IMU.\n\nA classifier will be trained and evaluated using leave-one-subject-out cross-validation.\n\nSafety & Feasibility:\n\nThe participant will be seated comfortably in a quiet room. The throat microphone will be secured using an adjustable elastic neck band. The IMU will be adhered to the participant’s jaw using medical tape. Participants will be asked to minimize head movement and perform articulations at a natural, silent pace.", "three_class_category": "N/A", "violated_constraint": "suboptimal", "violated_principle": "IMU placement and motion artifact susceptibility", "why_invalid": "Attaching the IMU to the jaw is physically feasible and captures relevant articulatory movements, but it is suboptimal because the jaw is a high-motion zone. This placement is likely to introduce signal contamination from incidental movements (e.g., swallowing or minor adjustments), reducing the signal-to-noise ratio of the kinematic data. It is not fatal because the main jaw motion is still recorded and usable for analysis.", "minimal_fix": "Relocate the IMU to a more stable site such as the forehead or mastoid process to reduce motion artifacts, while still capturing meaningful articulatory motion, ensuring cleaner kinematic signals for silent speech analysis.", "difficulty": "medium", "surface_plausibility": "high", "severity": "minor", "source_correct_protocol": "", "what_changed": "Minor Suboptimal Issue: The IMU placement on the jaw, while capturing relevant articulatory motion, is suboptimal as it is a high-motion artifact zone. This placement will likely record significant signal contamination from incidental jaw movements (e.g., swallowing, minor adjustments) unrelated to the target silent speech, potentially degrading the signal-to-noise ratio of the kinematic data. A more stable location, such as the forehead or mastoid process, would provide cleaner reference motion, though it may capture less direct articulatory information.\n数据泄露" }, { "id": "gold_0507_000681", "source_id": "8bf07ce296af", "domain": "sEMG_gesture", "scenario": "sEMG_gesture", "label": "valid", "protocol": "Protocol: sEMG-Based Hand Gesture Recognition System Validation\n\nObjective: To establish a standardized procedure for acquiring and processing surface electromyography (sEMG) signals from the forearm for hand gesture classification, comparing the performance of wet gel, dry, and high-density electrode arrays.\n\nEquipment: sEMG Amplifier with 24-bit ADC, input impedance >10^12 Ω, CMRR >100 dB; Electrodes including pre-gelled Ag/AgCl (wet), dry stainless steel, and 4x4 high-density array (8mm inter-electrode distance); Data Acquisition Unit capable of 2 kHz sampling rate per channel; Ground Electrode: Ag/AgCl on the olecranon process; Dynamometer for validating consistent muscle contractions.\n\nSensor Placement & Configuration: Clean skin with abrasive gel and alcohol over the right forearm. For wet electrodes, abrade gently. Electrode placement follows SENIAM guidelines. Place a bipolar pair over the Flexor Digitorum Superficialis and Extensor Digitorum Communis. For the array, center it over the muscle belly of the Extensor Digitorum Communis. The ground electrode is placed on bony prominence. Record electrode impedance: <5 kΩ for wet, <20 kΩ for dry/array.\n\nData Acquisition Procedure: Subject performs five repetitions of six gestures (fist, wrist flexion/extension, finger pinch, point, rest) with 3-second contractions at 50% MVC (verified by dynamometer), with 5-second rest between contractions. Acquire sEMG at 2 kHz sampling rate. Simultaneous acquisition from all three electrode systems is preferred.\n\nSignal Processing & Validation: Preprocessing involves applying a 20-500 Hz bandpass filter and a 50/60 Hz notch filter. Feature extraction is performed for each 200ms sliding window with 50% overlap, computing Root Mean Square (RMS), Mean Absolute Value (MAV), and waveform length. Validation includes splitting data 70/30 for training/testing of a Linear Discriminant Analysis classifier, calculating classification accuracy and confusion matrix for each electrode type, and performing a repeated-measures ANOVA to compare accuracy across electrode systems (α=0.05).\n\nSafety & Feasibility: Safety considerations include skin preparation with abrasive gel and alcohol to ensure proper electrode contact and minimize skin irritation, with gentle abrasion for wet electrodes. Feasibility is demonstrated by the expected outcomes where dry electrodes and the high-density array show practical applicability for hand gesture recognition, with the array offering spatial redundancy.", "three_class_category": "N/A", "violated_constraint": "none", "violated_principle": "", "why_invalid": "", "minimal_fix": "", "difficulty": "easy", "surface_plausibility": "high", "severity": "none", "source_correct_protocol": "", "what_changed": "" } ]