id
stringlengths
16
16
source_id
stringlengths
12
12
domain
stringclasses
6 values
scenario
stringclasses
6 values
label
stringclasses
3 values
protocol
stringlengths
1.59k
3.69k
three_class_category
stringclasses
4 values
violated_constraint
stringclasses
14 values
violated_principle
stringlengths
0
55
why_invalid
stringlengths
0
641
minimal_fix
stringlengths
0
287
difficulty
stringclasses
3 values
surface_plausibility
stringclasses
1 value
severity
stringclasses
3 values
source_correct_protocol
stringclasses
1 value
what_changed
stringclasses
11 values
gold_0507_000004
034560ce0e55
IMU_motion
IMU_motion
fatal_violation
Protocol: IMU-Based Wearable Motion Data Collection for Activity Recognition. Objective: To collect synchronized motion data using a custom wearable system with two inertial measurement units for activity recognition and orientation-estimation validation. The protocol targets classification of six activities, includ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The accelerometer bandwidth is set to 10 Hz, but the signal processing requires frequencies up to 20 Hz (low-pass filter cutoff at 20 Hz and features in the 10-20 Hz band). This bandwidth mismatch means the sensor cannot capture the necessary high-frequency componen...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000012
735250a8b05e
EEG_BCI
EEG_BCI
fatal_violation
Protocol: Concurrent EEG Acquisition for Motor Imagery Classification and P300 Detection. Objective: To acquire synchronized EEG data using wet gel EEG, dry EEG, and ear-EEG systems for motor imagery classification and P300 detection, retaining alpha, beta, and mu rhythms for motor imagery analysis and extracting P3...
Signal & Sampling
data_bandwidth
Communication bandwidth infeasibility
The required real-time raw data rate exceeds the practical sustained bandwidth of the communication link. Without compression, channel reduction, or local feature extraction, the data stream will suffer loss or excessive latency. In this sample, the problematic modification is: All systems will be time-synchronized via...
Reduce the transmitted data rate through local feature extraction, compression, channel reduction, or a lower sampling rate, or use a link with sufficient sustained bandwidth.
hard
high
fatal
gold_0507_000026
c7676440774e
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Acquisition for Upper Arm Gesture Classification. Objective: To acquire surface electromyography signals from eight targeted upper arm muscles using wet gel Ag/AgCl electrodes and a high-density dry electrode array, and to classify five target gestures and the rest state using extr...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement sEMG signals from upper arm muscles do not generate the target physiological signals for hand gestures; the classifier would fail to recognize gestures, resulting in accuracy near chance level (e.g., <20% for five gestures, far below the expected >95%). Fix: Place electrodes on forearm muscles t...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000033
fae92b42d874
radar_vital_signs
radar_vital_signs
valid
Protocol: FMCW Millimeter-Wave Radar Vital Sign Monitoring Objective: To monitor vital signs using FMCW millimeter-wave radar. Equipment: Texas Instruments IWR1443BOOST or equivalent 77-81 GHz FMCW radar module. The radar is configured with single transmit and three receive antennas (1Tx/3Rx) for angle estimation. Chir...
N/A
none
easy
high
none
gold_0507_000042
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Objective: To establish a validated method for capturing human motion and recognizing daily activities using inertial measurement units (IMUs). Equipment: 3x 9-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps, magnetometer ±4900 µT) and 3x 6-axis IMUs (acc...
N/A
none
easy
high
none
gold_0507_000057
914dd67962a0
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Classification Using Wet Gel, Dry, and Ear-EEG Systems. Objective: To acquire simultaneous EEG data from wet gel, dry electrode, and ear-EEG systems for classification of left hand, right hand, and foot motor imagery, and for P300 detection in a separate target/non-target t...
Signal & Sampling
snr_floor
Signal-to-noise floor violation
The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: The study will recruit 20 healthy, right-handed participants (age 18...
Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.
hard
high
fatal
gold_0507_000058
a96a98b00d23
IMU_motion
IMU_motion
fatal_violation
Protocol: IMU-Based Motion Capture and Activity Recognition Using 6-Axis and 9-Axis IMUs. Objective: To acquire motion data using a 6-axis MEMS IMU and a 9-axis IMU for orientation estimation, joint kinematics validation, and activity recognition across a dataset of 10 activities collected from 20 participants. Equ...
Signal & Sampling
data_bandwidth
Communication bandwidth infeasibility
The required real-time raw data rate exceeds the practical sustained bandwidth of the communication link. Without compression, channel reduction, or local feature extraction, the data stream will suffer loss or excessive latency. In this sample, the problematic modification is: Data were acquired using a 6-axis MEMS IM...
Reduce the transmitted data rate through local feature extraction, compression, channel reduction, or a lower sampling rate, or use a link with sufficient sustained bandwidth.
hard
high
fatal
gold_0507_000078
f4d56b051dd8
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Detection Using a Hybrid Wet Gel, Dry, and Ear-EEG Montage. Objective: To acquire EEG data using a hybrid electrode montage for cue-based motor imagery classification involving left hand, right hand, and feet movements, and to elicit P300 responses using a separate auditory...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Placing EEG electrodes on the upper trapezius muscle instead of the scalp fails to capture brain signals necessary for motor imagery and P300 detection. The target physiological signals for EEG are generated by the brain, not skeletal muscles, making the data acquisition invalid and expected per...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000081
52ccefd13bec
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via PTT from Synchronized PPG and ECG Objective: To estimate continuous blood pressure using pulse transit time derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals. Equipment: A single-lead clinical ECG module (e.g., AD8232) with pr...
N/A
none
easy
high
none
gold_0507_000088
d0f22401c1fb
IMU_motion
IMU_motion
fatal_violation
Protocol: IMU-Based Wearable Motion Capture and Activity Recognition. Objective: To perform motion capture using a custom wearable system composed of 9-axis and 6-axis IMUs, and to classify standardized human activities from synchronized inertial sensor data. Equipment: The custom wearable system comprises three B...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content, specifically the Nyquist theorem requiring sampling rate to be at least twice the highest signal frequency. The LSM6DSOX is sampled at 50 Hz, giving a Nyquist frequency of 25 Hz, but the low-pass filter has a cutoff at 40 Hz, allowing frequencies up to 40 Hz to pass...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000091
e2f748c1a454
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Recording from the Dominant Upper Arm for Static Hand Gesture Recognition. Objective: To record surface electromyography signals from the dominant upper arm of healthy adult participants and evaluate wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and a high-density gri...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Placing sEMG electrodes on upper arm muscles (e.g., biceps brachii) does not generate physiological signals corresponding to hand gestures, as hand movements are primarily controlled by forearm muscles. This misplacement makes the reported classification accuracies (e.g., 94.2%) physically impos...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000098
2ec6f075288e
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Acquisition for Electrode Performance Evaluation in Static Hand Gesture Recognition. Objective: To acquire surface electromyography signals using wet-gel Ag/AgCl electrodes and a dry stainless steel high-density electrode array, and to evaluate electrode performance for classificat...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem The sampling rate of 1000 Hz is less than twice the maximum signal frequency of 750 Hz (2 * 750 = 1500 Hz), causing aliasing and rendering the high-density sEMG data physically invalid for accurate signal reconstruction. Fix: Increase the sampling rate for the high-density system to at ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000113
7792fa1b540f
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition Using Throat Microphone and IMU Objective: To perform silent speech recognition by capturing throat vibrations and jaw movements using a piezoelectric contact microphone and an inertial measurement unit (IMU). Equipment: Throat Microphone: A piezoelectric contact microphone (e.g., Th...
N/A
none
easy
high
none
gold_0507_000124
7a8bdb24a2d2
sEMG_gesture
sEMG_gesture
valid
Protocol: sEMG-Based Hand Gesture Recognition Benchmark Objective: To establish a benchmark for classifying 10 distinct hand gestures using surface electromyography (sEMG), aiming for a mean classification accuracy of 95.0 ± 2.5%. Equipment: A 16-channel clinical-grade surface electromyography (sEMG) acquisition system...
N/A
none
easy
high
none
gold_0507_000125
786f091585f1
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Multi-Band FMCW Radar Monitoring for Non-Contact Vital Sign Estimation Objective: Assess non-contact vital sign monitoring performance across millimeter-wave radar bands using three FMCW radar modules and reference physiological recordings. Equipment: The experimental setup will use three frequency-modul...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The sampling rate of 0.002 MSPS (2 Hz) is below the Nyquist rate for the heart rate signal up to 2 Hz, which requires at least 4 Hz sampling to avoid aliasing, rendering vital sign measurements invalid. Fix: Increase the sampling rate of the 24GHz radar to at least ...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000128
e5441b31828d
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition Using Throat Microphone and IMU Objective: To develop and validate a silent speech recognition system by fusing signals from a throat microphone and an inertial measurement unit (IMU), targeting applications in assistive communication. Equipment: Throat Microphone: Piezoelectric co...
N/A
none
easy
high
none
gold_0507_000138
30ed82df6710
EEG_BCI
EEG_BCI
fatal_violation
Protocol: Concurrent EEG Sensor Technology Comparison for Motor Imagery BCI and P300 Detection Objective: Acquire EEG data using three concurrent systems to compare wet gel, dry electrode, and ear-EEG sensor technologies during a cue-based motor imagery BCI paradigm and a separate P300 oddball task. Equipment: EEG...
Physical / Hardware
accuracy_impossibility
Unrealistic performance claim
The stated performance exceeds the physical and statistical limits of the sensing modality. Sensor noise, calibration uncertainty, physiological variability, and reference-device error prevent the claimed precision. In this sample, the problematic modification is: A 32-channel dry electrode system (Cognionics Mobile 12...
Replace the unrealistic accuracy claim with a physically plausible performance target and include calibration, uncertainty, and reference-device error in validation.
hard
high
fatal
gold_0507_000139
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture for Upper and Lower Limb Activity Recognition Objective: To capture and classify human movement using 6-axis and 9-axis Inertial Measurement Units (IMUs) for robust activity recognition. Equipment: Four 6-axis IMUs (accelerometer ±16g, gyroscope ±2000 dps), two 9-axis IMUs (adding mag...
N/A
none
easy
high
none
gold_0507_000147
a9721bc62913
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Multi-Frequency FMCW Radar Evaluation for Non-Contact Vital Sign Monitoring Objective: Evaluate three commercially available FMCW radar modules for non-contact respiration rate and heart rate monitoring, using simultaneous clinical reference measurements for validation. Equipment: Three commercially avai...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The NI 6008 data acquisition card has a bandwidth of approximately 5 kHz, but the radar's IF signal frequencies are at least 10 kHz for the AWR1642 radar and up to 40 kHz for the IWR1443, so the card cannot capture the signal accurately, making the experiment physic...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000168
066e856393c6
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Benchmark Objective: To benchmark an IMU-based system for motion capture and activity recognition using specified hardware and procedures. Equipment: The system uses a 9-axis IMU module with an accelerometer (±16g range, 16-bit resolution, 1000 Hz max output...
N/A
none
easy
high
none
gold_0507_000170
a968fc9373f4
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG Recording for Motor Imagery and P300 BCI Tasks Using Wet, Dry, and Ear-EEG Systems Objective: Acquire EEG signals using wet gel, dry electrode, and ear-EEG systems to evaluate left/right hand motor imagery classification and P300 speller performance. Equipment: EEG signals will be acquired using a Bi...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
Anatomical misplacement: sensors must be placed on anatomy that generates the target physiological signal. Motor imagery signals are primarily generated in the sensorimotor cortex (central regions C3, C4, Cz), not the occipital cortex (O1, O2). Placing electrodes on O1 and O2 would capture visual-related activity, not ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000177
0fe2e8c6d897
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: 77 GHz FMCW Millimeter-Wave Radar for Non-Contact Vital Sign Monitoring Objective: Monitor respiration rate and heart rate using a 77 GHz FMCW millimeter-wave radar sensor and validate radar-derived estimates against simultaneous ECG and respiratory belt reference signals. Testing the system's tolerance to...
Physical / Hardware
temperature_range
Operating temperature violation
The protocol requires the electronics to operate outside their rated temperature range. Under those conditions, sensor accuracy, oscillator stability, battery behavior, and circuit reliability cannot be assumed. In this sample, the problematic modification is: Vital sign monitoring was performed using a 77GHz FMCW mill...
Restrict the experiment to the rated component temperature range or use components rated and validated for the claimed environment.
hard
high
fatal
gold_0507_000180
ac2386220b65
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Benchmark Objective: To benchmark the accuracy of IMU-based motion capture and activity recognition against ground truth systems. Equipment: Six Bosch BNO055 9-axis IMU modules (3-axis accelerometer, gyroscope, magnetometer) with integrated sensor fusion. Modu...
N/A
none
easy
high
none
gold_0507_000188
7663f4ec570f
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Multi-Frequency FMCW Radar Monitoring for Non-Contact Vital Sign Estimation Objective: Evaluate non-contact respiration rate and heart rate estimation using three frequency-modulated continuous wave radar modules operating at 24 GHz, 60 GHz, and 77 GHz. Equipment: The experimental setup will use three FM...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. For the 77 GHz radar system with a 4 GHz bandwidth and chirp duration of 1 ms (from 1 kHz chirp repetition), the maximum intermediate frequency is approximately 53.33 kHz, which exceeds the Nyquist frequency of 50 kHz f...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000189
7321638af989
EEG_BCI
EEG_BCI
valid
Protocol: EEG-BCI Motor Imagery Classification Protocol Objective: To classify kinesthetic motor imagery of left hand, right hand, and feet movements using an EEG-based brain-computer interface. Equipment: Use a research-grade EEG system (e.g., g.tec g.USBamp) with 16 active Ag/AgCl electrodes. Place electrodes accordi...
N/A
none
easy
high
none
gold_0507_000191
ba24a41d00d9
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography Recording for Static Leg Gesture Classification Objective: Record surface electromyography signals from the dominant forearm of 10 healthy participants during six static leg gestures and compare classification performance across three sensor configurations. Equipment: The study w...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement sEMG sensors placed on forearm muscles cannot generate physiological signals for leg gestures, as leg movements are controlled by leg muscles (e.g., quadriceps, hamstrings), not forearm muscles, making the experiment physically invalid. Fix: Either change the sensor placement to appropriate leg ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000206
2f956bb4792c
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Silent Speech Recognition Using a Contact Microphone and IMU Objective: Acquire synchronized contact microphone and IMU signals from five healthy participants during silent articulation, and classify silent utterances from a 100-word vocabulary using combined acoustic and laryngeal kinematic features. Equ...
Signal & Sampling
adc_resolution
ADC resolution limitation
The ADC resolution is too coarse for the expected signal amplitude. The quantization step can exceed meaningful physiological signal variations, preventing reliable measurement. In this sample, the problematic modification is: Data was collected from five healthy participants (3 male, 2 female; age 25-35)..
Use a higher-resolution ADC and, where needed, an analog front-end with appropriate gain so that the expected low-amplitude signal can be resolved.
hard
high
fatal
gold_0507_000212
aac54599607d
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Estimation Using Wearable PPG and ECG Sensors Objective: Estimate continuous blood pressure using a custom wearable device integrating photoplethysmography and electrocardiography sensors, with pulse transit time converted to blood pressure through subject-specific calibration. E...
Perception & Anatomy
optical_obstruction
Optical signal-path obstruction
PPG relies on light transmission/reflection; opaque obstacles block optical path. Stainless steel is opaque to green (525 nm) and infrared (940 nm) light, completely blocking the optical path, so no PPG signal can be acquired, rendering PTT calculation and BP estimation impossible as per the protocol's reliance on PPG ...
Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.
easy
high
fatal
gold_0507_000241
56c4e21f404a
PPG_BP
PPG_BP
valid
Protocol: Continuous blood pressure tracking using synchronized photoplethysmography (PPG) and electrocardiography (ECG) to derive pulse transit time (PTT) for beat-to-beat estimation. Objective: To continuously estimate systolic (SBP) and diastolic blood pressure (DBP) from PTT derived from ECG and PPG signals. Eq...
N/A
none
easy
high
none
gold_0507_000244
a062adbf629b
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit (IMU) Objective: To develop a benchmark dataset for silent speech recognition by capturing sub-vocalized speech using a throat microphone and accompanying head movement data via an IMU. Equipment: A commercially available piezoele...
N/A
none
easy
high
none
gold_0507_000246
0c975e3e3a7b
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG Recording for Motor Imagery and P300 Detection Using Wet, Dry, and Ear-EEG Systems Objective: Acquire EEG data using wet gel, dry electrode, and ear-EEG systems to evaluate three-class motor imagery classification and binary P300 detection. Equipment: EEG data will be acquired using three electrode s...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Motor imagery generates mu (8–12 Hz) and beta (13–30 Hz) rhythms primarily in the sensorimotor cortex (C3, Cz, C4). Applying CSP to parietal electrodes (Pz, POz) would not capture these rhythms, making feature extraction and classification physically impossible as the target physiological signal...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000248
e8e1c7343fe6
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Multimodal Silent Speech Interface via Contact Microphone and Inertial Measurement Unit Fusion Objective: To construct and evaluate a silent speech interface system that captures subvocalization signals and laryngeal/jaw kinematics to achieve sequence recognition with a target word error rate (WER) of <15% a...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The IMU sampling rate of 10 Hz results in a Nyquist frequency of 5 Hz, which is lower than the 20 Hz low-pass filter cutoff, causing aliasing and making accurate signal reconstruction impossible. Fix: Increase the IMU sampling rate to at least 40 Hz to satisfy the N...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000252
c33bb72d9ec1
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG data will be acquired using a g.tec g.USBamp amplifier connected to wet, dry, and ear-EEG electrodes during a cue-based motor imagery paradigm and a separate P300 detection pipeline. Objective: The objective is to record EEG signals for motor imagery classification and P300 detection, compare performan...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement: Sensor must be placed on anatomy that generates the target physiological signal. EEG signals are generated by brain activity and require electrode placement on the scalp or near the head (e.g., concha for ear-EEG). Placing electrodes on the wrist, which is a limb, will not capture EEG signals, ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000259
142104d1965d
sEMG_gesture
sEMG_gesture
valid
Protocol: sEMG-Based Hand Gesture Recognition Benchmark Objective: To benchmark a sEMG-based hand gesture recognition system using a standardized experimental protocol. Equipment: A 16-channel wireless sEMG system (e.g., Delsys Trigno Avanti) with Ag/AgCl dry electrodes will be used. The system has a bandwidth of 20-45...
N/A
none
easy
high
none
gold_0507_000260
50f2a1204559
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Tracking Using PPG and ECG. Objective: To perform continuous blood pressure tracking using photoplethysmography and electrocardiography signals by extracting pulse wave features, ECG R-peaks, PTT, and PWV for blood pressure estimation. Equipment: PPG signals will be acquired usi...
Physical / Hardware
power_budget
Power budget infeasibility
The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: First, the user wants me to generate a detailed...
Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.
hard
high
fatal
gold_0507_000261
5857d65bd040
IMU_motion
IMU_motion
fatal_violation
Protocol: Motion data were captured using two IMU systems and validated against an optical motion capture system during standardized activity trials. Objective: The objective is to acquire motion data for activity classification and joint-angle estimation, compare IMU-derived kinematic outputs against optical motion...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The accelerometer bandwidth of 0-10 Hz is insufficient to capture frequency components above 10 Hz, such as those in walking and running (which typically have content up to 20-30 Hz), resulting in loss of critical signal data and invalid kinematic measurements. Fix:...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000264
a0ece592e15f
EEG_BCI
EEG_BCI
fatal_violation
Protocol: Multi-Modal EEG Recording for Motor Imagery Classification Objective: Acquire EEG signals using wet gel, dry headband, and in-ear EEG sensors to evaluate cue-based motor imagery classification across separate and fused electrode modalities. Equipment: EEG signals will be acquired using three electrode ty...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. The hardware bandpass filter limits the signal to a maximum frequency of 100 Hz, requiring a sampling rate of at least 200 Hz to avoid aliasing. With a sampling rate of 120 Hz, which is below 200 Hz, the experiment violates the ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000267
a53c5bb3881e
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Classification Using Wet Gel, Dry, and Ear-EEG Systems Objective: Acquire EEG data using wet gel, dry electrode, and ear-EEG systems to evaluate three-class motor imagery classification and binary P300 detection. Equipment: EEG data will be acquired using three electrode ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The sampling rate of 64 Hz results in a Nyquist frequency of 32 Hz, which is less than the maximum signal frequency of 40 Hz from the bandpass filter, causing aliasing and invalidating data for frequencies above 32 Hz. ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000277
15e9d586cb3d
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Silent Speech Recognition Using a Contact Microphone and IMU Objective: Acquire subvocalization vibration and laryngeal movement signals from healthy adult participants to perform silent speech recognition on a 100-word vocabulary. Equipment: Data will be collected from healthy adult participants seated ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The microphone has a bandwidth of 50-500 Hz, but the bandpass filter requires frequencies up to 4000 Hz to isolate speech-related vibrations, so frequencies above 500 Hz cannot be captured, making the experiment physically impossible. Fix: Use a microphone with a fr...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000282
41543f72923a
IMU_motion
IMU_motion
fatal_violation
Protocol: Wearable IMU-Based Daily Activity Recognition Objective: Collect motion data from ten healthy adult participants performing daily activities, process inertial signals from five wireless IMU nodes, and classify sitting, standing, walking, and stair climbing. Equipment: Motion data will be collected from t...
Physical / Hardware
temperature_range
Operating temperature violation
The protocol requires the electronics to operate outside their rated temperature range. Under those conditions, sensor accuracy, oscillator stability, battery behavior, and circuit reliability cannot be assumed. In this sample, the problematic modification is: Motion data were collected from ten healthy adult participa...
Restrict the experiment to the rated component temperature range or use components rated and validated for the claimed environment.
hard
high
fatal
gold_0507_000296
d3a9a880386f
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit (IMU) Objective: To develop a silent speech interface by capturing subvocalization-induced laryngeal vibrations and associated neck movements using a contact microphone and IMU, enabling the classification of a predefined vocabular...
N/A
none
easy
high
none
gold_0507_000302
212e01d08e0b
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface Electromyography (sEMG) Recording and Hand Gesture Classification Using Multiple Electrode Types Objective: Acquire sEMG signals from the dominant forearm during 10 distinct hand gestures and compare classification performance across three electrode types: wet gel, dry, and high-density arrays. Eq...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The bandpass filter limits the signal to a maximum frequency of 450 Hz, requiring a sampling rate of at least 900 Hz (2 * 450 Hz). The sampling rate of 800 Hz is below this threshold, leading to aliasing and invalidatin...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000317
91be97494458
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Subvocalized speech signals were recorded using a wearable device integrating a MEMS contact microphone and a 9-axis IMU, with audio and motion features fused for word-level classification. Objective: The objective is to recognize silent speech from a 100-word vocabulary by combining audio features from a ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The microphone bandwidth (50 Hz - 2 kHz) does not cover the upper frequency limit of the bandpass filter (4000 Hz), so frequencies above 2 kHz are not captured, leading to incomplete audio features and invalid MFCC extraction for speech signals. Fix: Use a microphon...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000325
50f2a1204559
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous blood pressure was estimated non-invasively using pulse transit time derived from synchronized ECG and PPG signals, with beat-to-beat BP compared against invasive arterial measurements during rest and mild exercise. Objective: The objective is to continuously monitor systolic and diastolic blood...
Physical / Hardware
power_budget
Power budget infeasibility
The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: Continuous blood pressure (BP) was estimated no...
Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.
hard
high
fatal
gold_0507_000330
94af7bc3db78
IMU_motion
IMU_motion
fatal_violation
Protocol: Motion data were recorded using a wearable sensor node integrating a 6-axis IMU and a 9-axis IMU. The data were processed to estimate segment orientation, compensate for gravity, and classify common daily activities, with validation against an optical motion capture system. Objective: The objective is to a...
Physical / Hardware
accuracy_impossibility
Unrealistic performance claim
The stated performance exceeds the physical and statistical limits of the sensing modality. Sensor noise, calibration uncertainty, physiological variability, and reference-device error prevent the claimed precision. In this sample, the problematic modification is: Data were collected using a custom wearable sensor node...
Replace the unrealistic accuracy claim with a physically plausible performance target and include calibration, uncertainty, and reference-device error in validation.
hard
high
fatal
gold_0507_000338
8ac99e5395b7
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous blood pressure was tracked non-invasively using synchronized photoplethysmography and electrocardiography, with beat-to-beat BP estimated from pulse transit time and validated against a non-invasive reference device. Objective: The objective is to continuously estimate systolic and diastolic blo...
Perception & Anatomy
optical_obstruction
Optical signal-path obstruction
optical_obstruction: PPG relies on light transmission/reflection; opaque obstacles block optical path. The opaque tape blocks the 530 nm green LED light from the PPG sensor, preventing light penetration and reflection from the skin, which is essential for PPG signal acquisition. This makes it physically impossible to o...
Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.
easy
high
fatal
gold_0507_000342
914dd67962a0
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG data were recorded using a hybrid 16-channel system combining wet gel, dry, and ear-EEG electrodes for motor imagery and P300 speller tasks. Data were processed to extract CSP and ERP features for classification and evaluated using cross-validation. Objective: The objective is to classify motor imagery...
Signal & Sampling
snr_floor
Signal-to-noise floor violation
The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data were acquired using a 16-channel g.tec g.USBamp biosignal (...
Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.
hard
high
fatal
gold_0507_000354
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Objective: To acquire and process inertial data from wearable IMUs for the classification of daily living activities. Equipment: Two wireless 9-axis IMU units (e.g., Xsens MTw or equivalent). Each unit contains a tri-axial accelerometer (range: ±16g), gyroscop...
N/A
none
easy
high
none
gold_0507_000357
50f2a1204559
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Tracking Using PPG and ECG. Objective: To estimate continuous blood pressure using synchronized photoplethysmography and electrocardiography signals by extracting pulse wave features, ECG R-peaks, PTT, and PWV. Equipment: PPG signals will be captured with a custom sensor array i...
Physical / Hardware
power_budget
Power budget infeasibility
The claimed runtime or operating mode is inconsistent with the energy available from the stated power source. The device cannot sustain the described sensing, processing, and communication workload for the claimed duration. In this sample, the problematic modification is: First, the user wants a detailed experimental p...
Revise the battery capacity, duty cycle, sampling rate, processing load, or runtime claim so that total energy consumption fits within the stated power budget.
hard
high
fatal
gold_0507_000358
85892f2adcf9
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: FMCW Radar-Based Vital Sign Monitoring Objective: To non-invasively measure respiration rate (RR) and heart rate (HR) using three frequency-modulated continuous-wave (FMCW) radar modules at 24, 60, and 77 GHz, and to validate the measurements against clinical reference devices. Equipment: 24 GHz radar: I...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. The sampling rate of 5 kSPS is less than twice the maximum IF frequency of 8 kHz for the 60 GHz and 77 GHz radars, leading to aliasing and invalid data acquisition. Fix: Increase the sampling rate to at least 16 kSPS, such as re...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000380
da2690e12c13
EEG_BCI
EEG_BCI
valid
Protocol: EEG-Based Motor Imagery BCI Benchmark Objective: To establish a standardized benchmark for classifying left-hand versus right-hand motor imagery using an EEG-based brain-computer interface. Equipment: A research-grade, active electrode EEG system (e.g., g.tec g.USBamp or BioSemi ActiveTwo) with a minimum of 1...
N/A
none
easy
high
none
gold_0507_000381
2d848673c0b2
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous blood pressure (BP) estimation was performed using a custom wearable sensor integrating photoplethysmography (PPG) and electrocardiography (ECG). Participants underwent rest and mild exercise protocols while simultaneous reference BP measurements were collected. Pulse transit time (PTT) and pulse ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG signal is bandpass filtered to 0.5–40 Hz, so the maximum frequency is 40 Hz. The required sampling rate is at least 80 Hz, but the protocol uses 70 Hz, which is insufficient and will cause aliasing, invalidating...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000393
8d8218292f48
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via PPG and ECG Pulse Wave Analysis Objective: To develop and validate a continuous blood pressure estimation method using photoplethysmography (PPG) and electrocardiography (ECG) pulse wave analysis in healthy adults. Equipment: A reflective, wrist-worn PPG sensor with ...
N/A
none
easy
high
none
gold_0507_000394
914dd67962a0
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Speller Recording Objective: To acquire and analyze EEG signals from multiple electrode configurations for motor imagery (MI) classification and P300 speller detection. Equipment: g.tec g.USBamp biosignal amplifier, 64 channels, 24-bit ADC, 512 Hz sampling 16 active wet ...
Signal & Sampling
snr_floor
Signal-to-noise floor violation
The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data will be acquired using a 64-channel g.tec g.USBamp biosigna...
Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.
hard
high
fatal
gold_0507_000396
d20e93d90317
throat_mic_speech
throat_mic_speech
valid
Protocol: Silent Speech Recognition via Throat Microphone and Inertial Measurement Unit Objective: To develop a benchmark dataset for silent speech recognition by capturing subvocalized speech using a throat microphone and associated head/jaw kinematics using an inertial measurement unit (IMU). Equipment: Throat Micr...
N/A
none
easy
high
none
gold_0507_000398
914dd67962a0
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG-Based Motor Imagery and P300 Recording with Multiple Electrode Configurations Objective: To acquire and analyze EEG signals using wet, dry, and ear-EEG electrodes for motor imagery (MI) classification and P300 detection. Equipment: g.USBamp biosignal amplifier (g.tec Medical Engineering, Austria), 25...
Signal & Sampling
snr_floor
Signal-to-noise floor violation
The target signal is too weak to be measured reliably under the stated acquisition chain. Without adequate amplification, shielding, or noise control, the signal remains below the practical noise floor. In this sample, the problematic modification is: EEG data will be acquired using a g.USBamp biosignal (g.tec Medical ...
Add a low-noise preamplifier, proper shielding, grounding, and signal conditioning before digitization.
hard
high
fatal
gold_0507_000406
cc94bf30c229
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Tracking Using Multi-Modal PPG and ECG Objective: To continuously estimate blood pressure (BP) non-invasively using pulse transit time (PTT) derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals. Equipment: PPG sensor: ADPD4100 reflectance se...
Perception & Anatomy
optical_obstruction
Optical signal-path obstruction
Optical obstruction: PPG relies on unobstructed light transmission/reflection, and opaque materials block the optical path. The stainless steel watch band is opaque to the PPG wavelengths (530 nm, 660 nm, 850 nm), preventing light from reaching the photodetector. This results in no detectable PPG signal, making PTT cal...
Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.
easy
high
fatal
gold_0507_000407
90d109278d81
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Continuous-wave vital sign monitoring was performed using three FMCW radar modules to non-invasively measure respiration and heart rate in seated subjects. Objective: To assess the accuracy of different radar frequency bands (77 GHz, 60 GHz, 24 GHz) for continuous non-contact monitoring of respiration and ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
The acquisition setting violates the Nyquist-Shannon sampling requirement. The sampling rate is insufficient for the highest retained signal frequency, so aliasing can corrupt the measured signal and invalidate downstream analysis. In this sample, the problematic modification is: Each radar was positioned 1.5 meters fr...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000420
cc45683dad38
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Surface electromyography (sEMG) signals were recorded from the dominant forearm using three electrode types across separate sessions to evaluate hand gesture recognition. Objective: To compare the performance of wet gel, dry, and high-density electrode configurations for classifying static hand gestures us...
Signal & Sampling
latency_constraint
System latency infeasibility
The claimed end-to-end latency is incompatible with the stated communication or processing path. The transmission and computation delays exceed the required control-loop timing budget. In this sample, the problematic modification is: Surface electromyography (sEMG) signals were recorded from the dominant forearm using ...
Replace the unrealistic latency claim with a feasible timing budget, or use a local wired or otherwise low-latency processing path.
hard
high
fatal
gold_0507_000430
8d8218292f48
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via Pulse Transit Time (PTT) Objective: To estimate continuous blood pressure using Pulse Transit Time (PTT) derived from ECG and PPG signals. Equipment: PPG sensor (reflectance-mode with green 530 nm and IR 940 nm LEDs), single-lead ECG system, clinically validated osci...
N/A
none
easy
high
none
gold_0507_000439
10ad40eaa2fc
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Silent Speech Recognition Using MEMS Contact Microphone and 9-Axis IMU Objective: To capture subvocalization vibrations and laryngeal movements for silent speech recognition and evaluate classification performance on a 100-word vocabulary. Equipment: MEMS contact microphone (Knowles SPU0410LR5H-QB) with ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem The IMU sampling rate of 50 Hz is less than twice the maximum signal frequency of 50 Hz (from the low-pass filter cutoff), violating the Nyquist criterion and making accurate signal reconstruction impossible due to aliasing. Fix: Increase the IMU sampling rate to at least 100 Hz to sati...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000442
d3a9a880386f
throat_mic_speech
throat_mic_speech
valid
Protocol: Throat Microphone and IMU Silent Speech Data Acquisition Objective: To collect synchronized, high-fidelity vibration and motion data from a throat microphone and inertial measurement unit (IMU) during silent and spoken articulation for silent speech recognition model development. Equipment: Throat Microphone:...
N/A
none
easy
high
none
gold_0507_000449
92ef014ff9c8
EEG_BCI
EEG_BCI
fatal_violation
Protocol: EEG Recording and Analysis for Motor Imagery and P300 Speller Using Multiple Electrode Technologies Objective: To compare the performance of wet gel, dry, and ear-EEG electrodes for motor imagery (MI) classification and P300 speller tasks, evaluating classification accuracy, information transfer rate, and ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. With a sampling rate of 150 Hz and a hardware filter allowing frequencies up to 100 Hz, the maximum signal frequency (100 Hz) exceeds the Nyquist frequency (75 Hz), causing aliasing and rendering the sampled data invalid for acc...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000457
6c03fa294aab
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Vital sign monitoring was performed using three commercial FMCW radar modules across different frequency bands to assess non-contact respiration and heart rate measurement. Objective: To evaluate the accuracy and reliability of 24 GHz, 60 GHz, and 77 GHz FMCW radars in estimating respiration rate (RR) and ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be >= 2x the maximum signal frequency. For the 77 GHz radar with 4 GHz bandwidth and chirp repetition frequency of 1 kHz (chirp time 1 ms), the maximum beat frequency for a target at 3.0 m is approximately 80 kHz, requiring a Nyquist sampling rate of at least 160 kHz...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000468
3688437fbf54
IMU_motion
IMU_motion
minor_issue
Protocol: IMU-Based Motion Capture for Daily Activity Recognition Objective: To capture acceleration and angular velocity signals using wearable IMUs for activity recognition during daily movements. Equipment: 9-axis IMU (accelerometer ±16g, gyroscope ±2000 dps, magnetometer) Adjustable straps and adhesive pads f...
N/A
suboptimal
Suboptimal but physically feasible experimental design.
The protocol remains physically feasible, but Objective: To establish a protocol for IMU-based motion capture and activity recognition, focusing on capturing acceleration and angular velocity signals during daily activities.. The protocol remains physically feasible, but the sampling or filtering margin is weak. This c...
Increase the sampling rate or adjust the effective analysis bandwidth to provide a more robust signal-processing margin.
medium
high
minor
gold_0507_000473
2ae7c707acc8
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: Comparative evaluation of non-contact vital sign monitoring using three FMCW radar modules at 77 GHz, 60 GHz, and 24 GHz, measuring respiration and heart rates simultaneously. Objective: To quantify the accuracy of multi-frequency FMCW radars in extracting respiration rate (RR) and heart rate (HR) from sea...
Physical / Hardware
ematerial_block
Physical medium or propagation blockage
The inserted material blocks or severely attenuates the physical propagation path required by the sensing modality. As a result, the sensor cannot receive the target signal under the stated configuration. In this sample, the problematic modification is: Three distinct FMCW radar modules were employed for comparative ev...
Remove or replace the blocking material so that the relevant acoustic, optical, or electromagnetic propagation path remains unobstructed.
easy
high
fatal
gold_0507_000487
cb626c87603b
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Monitoring Using a Wrist-Worn PPG-ECG Device Objective: To perform beat-to-beat blood pressure (BP) tracking using a wrist-worn device that integrates photoplethysmography (PPG) and electrocardiography (ECG) sensors, calibrated against a standard oscillometric reference and valida...
Perception & Anatomy
optical_obstruction
Optical signal-path obstruction
optical_obstruction – PPG relies on light transmission/reflection; opaque obstacles block optical path. The stainless steel cover is opaque to the PPG wavelengths (525 nm, 660 nm, 880 nm), completely blocking light from the LEDs from reaching the skin and preventing any reflected light from being detected, rendering PP...
Remove the opaque barrier and ensure direct optical coupling between the PPG emitter/detector and the skin.
easy
high
fatal
gold_0507_000490
6596c6eba1d9
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Objective: To capture full-body kinematics and classify ambulatory activities using a minimal, wearable inertial measurement unit (IMU) setup. Equipment: Five 9-axis IMU units (e.g., Xsens MTw), each containing a tri-axial accelerometer (range: ±16g), tri-ax...
N/A
none
easy
high
none
gold_0507_000491
cf27c42eb92a
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: sEMG Acquisition and Gesture Recognition from Calf Musculature Using Multiple Electrode Configurations Objective: To acquire and compare surface electromyography (sEMG) signals from the dominant calf using wet-gel, dry, and high-density electrode arrays, and to evaluate gesture recognition performance acro...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement Calf muscles do not generate sEMG signals for hand gestures; signals from them will not correlate with the intended gestures, making classification invalid. For example, the expected accuracy of 95% for wet-gel systems cannot be achieved as the data source is anatomically incorrect. Fix: Revert ...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000494
03026a9cce63
IMU_motion
IMU_motion
fatal_violation
Protocol: Full-body motion capture and activity recognition using a multi-IMU wearable system. Objective: To accurately capture human kinematics and classify daily activities using inertial measurement units (IMUs), validated against an optical motion capture system. Equipment: Seven Xsens MTi-3 9-axis IMUs (accel...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
sensor_bandwidth The sensor bandwidth is set to 50 Hz for accelerometer and 52 Hz for gyroscope, but the low-pass filter allows frequencies up to 80 Hz. Frequencies above 50 Hz (e.g., from high-acceleration movements) will not be accurately captured by the sensors, leading to aliasing or distorted signals, invalidating...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000498
214cea5e14a8
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: High-Resolution sEMG Acquisition and Gesture Classification Using Multi-Modal Electrode Configurations Objective: To record and analyze surface electromyography (sEMG) signals from the dominant upper arm across wet-gel, dry, and high-density electrode arrays, and to classify hand gestures and wrist movemen...
Perception & Anatomy
anatomical_misplacement
Anatomical placement inconsistency
anatomical_misplacement: sensors placed on anatomy that does not generate the target physiological signal for hand gesture recognition. The biceps brachii muscle primarily controls elbow flexion, not fine hand movements. sEMG signals from this location lack correlation with hand gestures, rendering the classification t...
Move the sensor to the anatomical site that generates the target signal and verify placement using the relevant anatomical landmarks.
easy
high
fatal
gold_0507_000501
cc45683dad38
sEMG_gesture
sEMG_gesture
fatal_violation
Protocol: Forearm sEMG Acquisition and Gesture Recognition Across Multi-Modal Electrode Configurations Objective: To investigate the impact of wet-gel, dry, and high-density sEMG electrode configurations on finger gesture recognition performance, with high temporal and spatial resolution for real-time applications. ...
Signal & Sampling
latency_constraint
System latency infeasibility
The claimed end-to-end latency is incompatible with the stated communication or processing path. The transmission and computation delays exceed the required control-loop timing budget. In this sample, the problematic modification is: Surface electromyography (sEMG) signals were recorded using three electrode configurat...
Replace the unrealistic latency claim with a feasible timing budget, or use a local wired or otherwise low-latency processing path.
hard
high
fatal
gold_0507_000504
d5a4c4e1f93d
radar_vital_signs
radar_vital_signs
valid
Protocol: Non-Contact Vital Signs Monitoring using 60 GHz FMCW Radar. Objective: To monitor respiration and heart rate using non-contact 60 GHz FMCW radar. Equipment: The radar module is a 60 GHz FMCW radar transceiver, such as Infineon BGT60TR13C, with a 5 GHz bandwidth from 57–64 GHz. This provides a range resol...
N/A
none
easy
high
none
gold_0507_000510
50172d3ff07d
IMU_motion
IMU_motion
valid
Protocol: IMU-Based Motion Capture and Activity Recognition Objective: To validate a wearable inertial measurement unit (IMU) system for accurate 3D motion capture and classification of common human activities (e.g., walking, sitting, stair ascent/descent). Equipment: IMU Sensors: 5x commercially available 9-axis IMU...
N/A
none
easy
high
none
gold_0507_000513
8d8218292f48
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via PTT/PWV Using Synchronized PPG and ECG Objective: To develop and validate a continuous, non-invasive blood pressure (BP) tracking system by measuring Pulse Transit Time (PTT) and Pulse Wave Velocity (PWV) derived from synchronized photoplethysmography (PPG) and electr...
N/A
none
easy
high
none
gold_0507_000514
8d8218292f48
PPG_BP
PPG_BP
valid
Protocol: Continuous Blood Pressure Estimation via PPG-ECG Pulse Transit Time Objective: To develop and validate a continuous, non-invasive blood pressure (BP) estimation model using Pulse Transit Time (PTT) derived from synchronously acquired photoplethysmography (PPG) and electrocardiography (ECG) signals. Equipmen...
N/A
none
easy
high
none
gold_0507_000516
73ef42c14345
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Estimation Using Pulse Transit Time from Synchronized PPG and ECG Objective: To estimate beat-to-beat systolic and diastolic blood pressure non-invasively using pulse transit time (PTT) derived from synchronized photoplethysmography (PPG) and electrocardiography (ECG) signals, and...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG bandpass filter is set to 0.05–150 Hz, so the maximum frequency is 150 Hz. The Nyquist rate requires at least 300 Hz sampling, but 250 Hz is below this, leading to aliasing and invalid signal acquisition for acc...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000521
54cc1242ebdb
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Silent speech recognition using a custom throat-mounted sensor array combining a MEMS contact microphone and a 9-axis IMU. Objective: To capture subvocalization signals and laryngeal motion for real-time classification of a 100-word silent speech vocabulary. Equipment: MEMS contact microphone (Knowles SP...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Sensor bandwidth must cover signal frequency content. The microphone bandwidth starts at 150 Hz, but the bandpass filter is set to 80–4000 Hz, so frequencies between 80 Hz and 150 Hz are not captured by the sensor, making the experiment invalid as critical low-frequency subvocalization vibrations are missed. Fix: Use a...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000534
2f956bb4792c
throat_mic_speech
throat_mic_speech
fatal_violation
Protocol: Neck-worn sensor array for silent speech recognition, combining a MEMS contact microphone and a 9-axis IMU to capture subvocalization and laryngeal kinematics. Objective: To evaluate the feasibility and accuracy of a multimodal neck-worn sensor system for silent speech recognition across a 200-word vocabul...
Signal & Sampling
adc_resolution
ADC resolution limitation
The ADC resolution is too coarse for the expected signal amplitude. The quantization step can exceed meaningful physiological signal variations, preventing reliable measurement. In this sample, the problematic modification is: The microphone was affixed over the thyroid cartilage using medical adhesive, while the IMU w...
Use a higher-resolution ADC and, where needed, an analog front-end with appropriate gain so that the expected low-amplitude signal can be resolved.
hard
high
fatal
gold_0507_000550
d1f779307b4d
PPG_BP
PPG_BP
fatal_violation
Protocol: Continuous Blood Pressure Estimation Using a Wearable PPG-ECG Device Objective: To estimate beat-to-beat systolic and diastolic blood pressure non-invasively using pulse transit time derived from synchronized PPG and single-lead ECG signals in healthy adults during rest and mild exercise. Equipment: PPG ...
Signal & Sampling
sampling_theorem
Signal sampling infeasibility
Nyquist-Shannon sampling theorem: sampling rate must be at least twice the maximum signal frequency. The ECG signal is bandpass filtered to 0.5–30 Hz, so the maximum frequency is 30 Hz. The Nyquist rate requires a sampling rate of at least 60 Hz to avoid aliasing, but the ECG is sampled at 50 Hz, which is less than 60 ...
Increase the sampling rate to at least twice the highest retained signal frequency, preferably with additional margin for anti-aliasing filter transition bands.
medium
high
fatal
gold_0507_000555
85250c997977
radar_vital_signs
radar_vital_signs
fatal_violation
Protocol: A controlled laboratory study using three FMCW radar systems to non-invasively monitor cardiopulmonary activity in seated participants, with cross-validation against clinical reference devices. Objective: To evaluate the accuracy of non-contact respiration rate (RR) and heart rate (HR) measurements across ...
Signal & Sampling
sensor_bandwidth
Sensor bandwidth mismatch
Nyquist-Shannon sampling theorem: the sampling rate must be at least twice the highest frequency of the signal to avoid aliasing. With a sampling rate of 1 Hz, the Nyquist frequency is 0.5 Hz, which is lower than the heart rate signal frequency range of 0.8–2.0 Hz, causing aliasing and making accurate heart rate measur...
Use a sensor and analog front-end whose bandwidth covers the full analyzed signal band, or reduce the acquisition and filtering bandwidth to match the hardware response.
medium
high
fatal
gold_0507_000584
93b573fe8d29
sEMG_gesture
sEMG_gesture
minor_issue
Protocol: High-Density sEMG Acquisition for Hand Gesture Classification Objective: To acquire surface electromyography (sEMG) signals from the forearm for the classification of five distinct hand gestures (power grasp, key pinch, wrist extension, wrist flexion, and hand open). Equipment: 8-channel sEMG system (Bagnoli ...
N/A
suboptimal
Suboptimal but physically feasible experimental design.
The protocol remains physically feasible, but 错误提示: 1. 10次手势重复不够 2. 数据集划分有误: 70/30混合划分无法展示模型泛化能力,应该使用80/20 LOSO. The setting is suboptimal because the sampling margin is small, leaving limited room for anti-aliasing filter transition bands and making near-cutoff components more vulnerable to distortion. It is not a fat...
Increase the sampling rate or lower the effective analysis bandwidth to provide a safer anti-aliasing margin.
medium
high
minor
错误提示: 1. 10次手势重复不够 2. 数据集划分有误: 70/30混合划分无法展示模型泛化能力,应该使用80/20 LOSO
gold_0507_000586
b5e62808f32d
EEG_BCI
EEG_BCI
valid
Protocol: EEG-Based Motor Imagery Brain-Computer Interface System Validation Objective: To validate an EEG-BCI system for classifying left-hand vs. right-hand motor imagery using a hybrid sensor approach. Equipment: BioSemi ActiveTwo EEG amplifier with 24-bit ADC and 1000 Hz sampling rate. Electrodes include a 16-cha...
N/A
none
easy
high
none
gold_0507_000590
b5e62808f32d
EEG_BCI
EEG_BCI
valid
Protocol: EEG-Based Motor Imagery Brain-Computer Interface System Validation. Objective: To validate a multi-modal EEG-BCI system for classifying left-hand vs. right-hand motor imagery using a combination of wet gel, dry, and ear-EEG electrodes, targeting sensorimotor rhythms in the mu/beta range of 8–30 Hz. Equipm...
N/A
none
easy
high
none
gold_0507_000594
8bf07ce296af
sEMG_gesture
sEMG_gesture
valid
Protocol: sEMG-Based Hand Gesture Recognition System Validation Objective: To validate a surface electromyography (sEMG) system for robust classification of 5 distinct hand gestures. Equipment: 8-channel wet-gel Ag/AgCl electrodes (Ambu Neuroline 720) and 8-channel dry stainless steel electrodes (custom array). High-...
N/A
none
easy
high
none
gold_0507_000596
8bf07ce296af
sEMG_gesture
sEMG_gesture
valid
Protocol: Multi-Sensor sEMG Gesture Recognition System Validation Objective: To acquire and classify surface electromyography (sEMG) signals from forearm muscles for a set of 8 predefined hand gestures, utilizing and comparing three sensor modalities: wet gel Ag/AgCl electrodes, dry stainless steel electrodes, and a h...
N/A
none
easy
high
none
gold_0507_000597
8bf07ce296af
sEMG_gesture
sEMG_gesture
valid
Protocol: High-Density sEMG Acquisition for Hand Gesture Recognition Objective: To acquire and validate surface electromyography (sEMG) signals for the classification of six distinct hand gestures using a multi-modal electrode array. Equipment: The sEMG system is a commercial 32-channel sEMG amplifier (e.g., Delsys T...
N/A
none
easy
high
none
gold_0507_000598
8bf07ce296af
sEMG_gesture
sEMG_gesture
valid
Protocol: Comparative Evaluation of sEMG Electrode Systems for Hand Gesture Recognition Objective: To assess the performance of wet gel Ag/AgCl, dry stainless steel, and high-density electrode arrays for classifying five hand gestures using surface electromyography (sEMG). Equipment: Bagnoli desktop system with wet gel...
N/A
none
easy
high
none
gold_0507_000599
bb4c993bd534
radar_vital_signs
radar_vital_signs
minor_issue
Protocol: Non-Contact Vital Sign Monitoring Using FMCW Millimeter-Wave Radar Objective: To develop a standardized protocol for extracting respiration rate (RR) and heart rate (HR) from human subjects using a frequency-modulated continuous wave (FMCW) radar operating in the 60-GHz band, and to validate the measurements...
N/A
suboptimal
Suboptimal but physically feasible experimental design.
The protocol remains physically feasible, but 错误原因:5Hz的采样率对于2Hz的心跳来说只预留了1Hz的采样率空间,因此在实际工程应用时非最优. The setting is suboptimal because the sampling margin is small, leaving limited room for anti-aliasing filter transition bands and making near-cutoff components more vulnerable to distortion. It is not a fatal violation bec...
Increase the sampling rate or lower the effective analysis bandwidth to provide a safer anti-aliasing margin.
medium
high
minor
错误原因:5Hz的采样率对于2Hz的心跳来说只预留了1Hz的采样率空间,因此在实际工程应用时非最优
gold_0507_000604
b5e62808f32d
EEG_BCI
EEG_BCI
valid
Protocol: EEG-Based BCI for Motor Imagery Classification Objective: To acquire and classify EEG signals during motor imagery tasks to validate a hybrid BCI system using wet gel, dry, and ear-EEG electrodes. Equipment: The EEG system is a 64-channel research-grade amplifier with 24-bit ADC and a sampling rate of 1000 Hz...
N/A
none
easy
high
none
gold_0507_000623
a677f056b289
radar_vital_signs
radar_vital_signs
minor_issue
Protocol: Non-Contact Monitoring of Heart Rate and Respiration using FMCW Millimeter-Wave Radar. Objective: To extract and validate heart rate and respiration rate signals from human subjects using a frequency-modulated continuous wave radar operating in the 60 GHz band. Equipment: The equipment includes a 60 GHz ...
N/A
suboptimal
Suboptimal but physically feasible experimental design.
The setting is suboptimal because the sampling margin is small, leaving limited room for anti-aliasing filter transition bands and making near-cutoff components more vulnerable to distortion. It is not a fatal violation because the nominal sampling condition is still approximately satisfied.
Increase the sampling rate or lower the effective analysis bandwidth to provide a safer anti-aliasing margin.
medium
high
minor
Minor Issue: The configured chirp bandwidth of 2.5 GHz, while functional, is suboptimal for this application. A bandwidth of 4-5 GHz would provide superior range resolution (~3.75 cm), enabling more precise spatial focusing solely on the moving thorax and better rejection of static clutter from the chair and other near...
gold_0507_000628
90592483921e
PPG_BP
PPG_BP
minor_issue
Protocol: Continuous Blood Pressure Estimation via Wrist-Worn PPG and ECG. Objective: To develop and validate a wearable system for continuous, cuff-less blood pressure estimation using photoplethysmography and electrocardiography signals derived from a single wrist-worn device. Equipment: The system uses a wrist-...
N/A
suboptimal
Signal resolution for precise PTT measurement
The 125 Hz sampling rate is physically sufficient for capturing PPG and ECG signals, but it provides only a minimal margin above the Nyquist limit. This suboptimal choice could reduce temporal precision in detecting PPG systolic peaks, leading to slight jitter in pulse transit time and potentially lower BP estimation a...
Increase the sampling rate to at least 250 Hz to improve temporal resolution of PPG and ECG signals, ensuring more precise detection of systolic peaks for pulse transit time calculation, while remaining within the capabilities of the wrist-worn device.
medium
high
minor
Minor Suboptimal Issue: The protocol specifies a sampling rate of 125 Hz for both signals. While this exceeds the Nyquist frequency for typical PPG/ECG waveforms (~1-35 Hz), it provides a minimal margin. This could limit the precision of detecting the exact PPG systolic peak for PTT calculation, potentially introducing...
gold_0507_000631
0f4e0eade5cc
EEG_BCI
EEG_BCI
minor_issue
Protocol: EEG-Based Motor Imagery Classification for Brain-Computer Interface Objective: To classify left-hand vs. right-hand motor imagery (MI) from EEG signals using common spatial patterns (CSP) and linear discriminant analysis (LDA). Equipment: 32-channel active electrode system (e.g., g.tec g.USBamp). Sensor Pl...
N/A
suboptimal
Signal sampling and validation robustness
The protocol uses a 256 Hz sampling rate and a simple 80/20 train-test split without cross-validation. While physically sufficient to capture EEG motor imagery signals, the limited Nyquist margin and absence of cross-validation make the experimental design suboptimal for reliably estimating classifier performance. It i...
Increase the sampling rate to at least 512 Hz to provide a larger Nyquist margin for capturing high-frequency EEG components, and implement k-fold cross-validation (e.g., 5-fold) on the training set to improve the reliability and generalizability of classification performance estimates.
medium
high
minor
1. 预留的Nyquist 冗余不够 2. 数据划分不理想,没有交叉验证
gold_0507_000633
0b0cc2597b1a
sEMG_gesture
sEMG_gesture
minor_issue
Protocol: Surface Electromyography for Hand Gesture Recognition Objective: To collect surface electromyography (sEMG) data from forearm muscles for the classification of eight static hand gestures. Equipment: 8-channel sEMG system with active electrodes, Ag/AgCl electrodes, abrasive skin preparation gel, elastic band...
N/A
suboptimal
Signal sampling resolution
The protocol uses a 500 Hz sampling rate for sEMG signals, which is physically sufficient to capture the relevant muscle activity. However, it is suboptimal because a slightly higher sampling rate could provide better temporal resolution for capturing rapid muscle activations, improving feature extraction precision. It...
Increase the sampling rate to 1000 Hz to improve temporal resolution and capture faster sEMG signal dynamics more accurately, while remaining within the capabilities of the acquisition system.
medium
high
minor
错误原因:采样率非最优
gold_0507_000639
b5e62808f32d
EEG_BCI
EEG_BCI
valid
Protocol: Protocol for EEG-Based Brain-Computer Interface Motor Imagery Classification Objective: To develop and validate an EEG-based BCI system for classifying left-hand versus right-hand motor imagery using mu (8–12 Hz) and beta (13–30 Hz) rhythms, with optional integration of P300 for hybrid validation. Equipment...
N/A
none
easy
high
none
gold_0507_000644
070be4101af3
IMU_motion
IMU_motion
minor_issue
Protocol: IMU-Based Motion Capture for Gait Analysis Objective: To collect lower-limb kinematic data using inertial measurement units (IMUs) for the purpose of training a gait phase classification algorithm. Equipment: 5x commercial-grade IMUs (Xsens MTw), 3-axis accelerometer and gyroscope. Elastic straps and medical ...
N/A
suboptimal
IMU sampling rate relative to signal frequency
Sampling the IMUs at 100 Hz is physically feasible for capturing lower-limb kinematics, but the Nyquist margin is minimal, providing limited redundancy for higher-frequency gait dynamics. This suboptimal setting could slightly reduce the accuracy of detecting rapid events such as heel strike and toe-off. It is not fata...
Increase the IMU sampling rate to at least 200 Hz to provide greater Nyquist redundancy, improving temporal resolution and the precision of event detection in dynamic gait analysis.
medium
high
minor
错误原因:预留的Nyquist冗余不够
gold_0507_000657
0373d749e2a6
EEG_BCI
EEG_BCI
minor_issue
Protocol: EEG-Based Motor Imagery Classification for BCI Objective: To collect and classify EEG signals during motor imagery tasks for a brain-computer interface, distinguishing between left-hand and right-hand imagination. Equipment: 32-channel EEG system (e.g., g.tec g.USBamp), Active electrodes in a 10-20 system m...
N/A
suboptimal
Electrode impedance and EEG signal fidelity
Maintaining electrode impedance below 20 kΩ is physically feasible and allows for interpretable EEG recordings in the mu and beta bands. However, this is suboptimal compared to the ideal <5 kΩ threshold, as higher impedance can introduce noise and reduce signal-to-noise ratio, particularly in higher-frequency component...
Reduce electrode impedance to below 5 kΩ using additional conductive gel and skin preparation to improve signal-to-noise ratio and ensure higher fidelity for high-frequency EEG components.
medium
high
minor
Note on Data Quality: The specified impedance threshold of 20 kΩ is higher than the ideal <5 kΩ standard, which may increase noise and reduce signal-to-noise ratio, particularly for high-frequency components. However, the signal should remain interpretable for the primary task of broad mu/beta band classification. 不要出现...
gold_0507_000662
1a938b312419
IMU_motion
IMU_motion
minor_issue
Protocol: IMU-Based Motion Capture for Upper-Limb Activity Recognition Objective: To collect and classify upper-limb daily activities using a single inertial measurement unit (IMU) and a supervised machine learning model. Equipment: One commercial 9-axis IMU (accelerometer, gyroscope, magnetometer) with Bluetooth con...
N/A
suboptimal
IMU sampling rate and high-frequency motion capture
Streaming IMU data at 50 Hz is physically feasible and sufficient for capturing gross upper-limb movements, but the minimal Nyquist margin may underrepresent higher-frequency components during rapid movements, limiting temporal resolution. This setup is not fatal because the primary activities are still captured adequa...
Increase the IMU sampling rate to at least 100 Hz to provide additional Nyquist redundancy, improving temporal resolution and ensuring more accurate capture of rapid upper-limb motions.
medium
high
minor
1. 预留的Nyquist冗余不足 2.
gold_0507_000666
d8af83210f18
throat_mic_speech
throat_mic_speech
minor_issue
Protocol: Silent Speech Recognition Using Throat Microphone and IMU. Objective: To collect a dataset of silent speech articulations using a throat microphone and inertial measurement unit for the development of a silent speech interface. Equipment: The system includes an accelerometer-based throat microphone with ...
N/A
suboptimal
IMU placement and motion artifact susceptibility
Attaching the IMU to the jaw is physically feasible and captures relevant articulatory movements, but it is suboptimal because the jaw is a high-motion zone. This placement is likely to introduce signal contamination from incidental movements (e.g., swallowing or minor adjustments), reducing the signal-to-noise ratio o...
Relocate the IMU to a more stable site such as the forehead or mastoid process to reduce motion artifacts, while still capturing meaningful articulatory motion, ensuring cleaner kinematic signals for silent speech analysis.
medium
high
minor
Minor Suboptimal Issue: The IMU placement on the jaw, while capturing relevant articulatory motion, is suboptimal as it is a high-motion artifact zone. This placement will likely record significant signal contamination from incidental jaw movements (e.g., swallowing, minor adjustments) unrelated to the target silent sp...
gold_0507_000681
8bf07ce296af
sEMG_gesture
sEMG_gesture
valid
Protocol: sEMG-Based Hand Gesture Recognition System Validation Objective: To establish a standardized procedure for acquiring and processing surface electromyography (sEMG) signals from the forearm for hand gesture classification, comparing the performance of wet gel, dry, and high-density electrode arrays. Equipmen...
N/A
none
easy
high
none