{ "name": "pulmoeit", "version": "780c8b6", "created": "2026-10-04T23:13:21+00:00", "architecture": "postunet", "n_parameters": 117393, "onnx_sha256": "7785fa6e8473d5b835788bd371299b5310f22b927beb6d81e302a7ee4f056a36", "onnx_parity_max_abs_error": 8.866190910339355e-07, "input": { "name": "dv", "shape": [ "batch", 208 ], "description": "(v_insp - v_ref) / |v_ref|, 16 electrodes, adjacent protocol" }, "output": { "name": "image", "shape": [ "batch", 32, 32 ], "description": "tidal ventilation image, row 0 anterior, column 0 patient right" }, "training_data": { "source": "simulation (CEM FEM)", "acquisition": { "n_boundary": 224, "aspect_range": [ 0.64, 0.8 ], "fourier_std": 0.02, "electrode_jitter": 0.03, "snr_db": [ 50.0, 70.0 ], "breaths_per_patient": 4 }, "seed": 42 }, "evaluation": { "test": { "baseline": { "rmse": 0.07096016942030296, "corr": 0.8465843277263809, "gi_mae": 0.15773316114602445, "cov_mae": 0.6355953352988023, "regional_mae": 2.1213499164720986 }, "model": { "rmse": 0.017438047634847548, "corr": 0.9899952715680331, "gi_mae": 0.01701340313475504, "cov_mae": 0.24673379910094842, "regional_mae": 0.7648652980414369 }, "by_scenario": { "healthy": { "n": 282, "baseline_corr": 0.846637204650773, "model_corr": 0.9928934033730582 }, "dorsal_atelectasis": { "n": 161, "baseline_corr": 0.8537478232939759, "model_corr": 0.9842781477991743 }, "one_lung": { "n": 90, "baseline_corr": 0.8743163878510529, "model_corr": 0.9940357304777362 }, "pneumothorax": { "n": 107, "baseline_corr": 0.8160025588491707, "model_corr": 0.9886837714968743 }, "pleural_effusion": { "n": 160, "baseline_corr": 0.8441351388487538, "model_corr": 0.9892444775899694 } }, "qc_drift": { "n_current": 800, "ks_statistic": 0.03249999999999997, "p_value": 0.7856684786950764, "drift": false, "median_score_ratio": 0.9872667269518027 } }, "test_shift": { "baseline": { "rmse": 0.09013248500286171, "corr": 0.7646025215672358, "gi_mae": 0.15424668132138333, "cov_mae": 1.1613476416112543, "regional_mae": 3.5702883745800524 }, "model": { "rmse": 0.042214173940122286, "corr": 0.9386106900932437, "gi_mae": 0.03831899671148719, "cov_mae": 0.7355675842353628, "regional_mae": 2.19854934920667 }, "by_scenario": { "healthy": { "n": 276, "baseline_corr": 0.7703014576939349, "model_corr": 0.9488904088171668 }, "dorsal_atelectasis": { "n": 157, "baseline_corr": 0.7483600610738365, "model_corr": 0.9224563297506935 }, "one_lung": { "n": 78, "baseline_corr": 0.7935993165195385, "model_corr": 0.9454423384159566 }, "pneumothorax": { "n": 116, "baseline_corr": 0.7541547714297177, "model_corr": 0.9357164591185615 }, "pleural_effusion": { "n": 173, "baseline_corr": 0.7641825732213823, "model_corr": 0.9357314671445104 } }, "qc_drift": { "n_current": 800, "ks_statistic": 0.755, "p_value": 5.7646463057869766e-201, "drift": true, "median_score_ratio": 4.2296751195655995 } }, "qc": { "fault_auc": 1.0, "fault_detection_rate": 1.0, "false_alarm_rate": 0.00625, "electrode_localisation_acc": 0.9975 }, "gates": { "min_corr": true, "min_corr_gain_over_baseline": true, "max_cov_mae": true, "min_fault_auc": true, "passed": true } }, "intended_use": "Research prototype. Not a medical device, not for clinical decisions.", "limitations": [ "2D model of a 3D current flow; trained on simulations only (sim-to-real gap not yet measured).", "Single protocol (16 electrodes, adjacent drive).", "Clinical indices not validated against CT or clinical reference." ], "registre": { "version": "v0.3.0", "depot": "sheenee261/pulmoeit" } }