{ "excavation": { "unit": "m3", "count": 11, "min": 295.0, "max": 1400.0, "median": 750.0, "mean": 680.27, "stdev": 332.7, "values": [ 295.0, 295.0, 318.0, 450.0, 660.0, 750.0, 760.0, 780.0, 875.0, 900.0, 1400.0 ], "samples": [ "Excvation works", "Excvation works (as per soil report 1.5m)", "Excvation works (as per soil report 1.5m)" ] }, "road_base": { "unit": "m3", "count": 5, "min": 65.0, "max": 138.0, "median": 102.0, "mean": 106.4, "stdev": 30.65, "values": [ 65.0, 92.0, 102.0, 135.0, 138.0 ], "samples": [ "Roadbase Layer as per required (250 mm)", "Roadbase Layer as per required (200 mm)", "Roadbase Layer as per required (250 mm)" ] }, "backfill": { "unit": "m3", "count": 11, "min": 355.0, "max": 1465.0, "median": 790.0, "mean": 762.73, "stdev": 350.84, "values": [ 355.0, 355.0, 375.0, 475.0, 790.0, 790.0, 825.0, 900.0, 980.0, 1080.0, 1465.0 ], "samples": [ "Back filling work required & Compaction", "Back filling work required", "Back filling work required" ] }, "foundation_pcc": { "unit": "m3", "count": 11, "min": 9.0, "max": 31.0, "median": 22.0, "mean": 20.09, "stdev": 8.1, "values": [ 9.0, 9.0, 12.0, 13.0, 20.0, 22.0, 24.0, 25.0, 26.0, 30.0, 31.0 ], "samples": [ "100mm thick PPC under footing & tie beams (as per spec. )", "100mm thick PPC under footing & tie beams", "100mm thick PPC under footing & tie beams" ] }, "foundation_concrete": { "unit": "m3", "count": 11, "min": 20.0, "max": 125.0, "median": 38.0, "mean": 50.82, "stdev": 31.96, "values": [ 20.0, 20.0, 25.0, 32.0, 37.0, 38.0, 48.0, 62.0, 72.0, 80.0, 125.0 ], "samples": [ "R.C.C Footings (as per approved drawings & consultant spec.)", "R.C.C Footings (as per approved drawings & consultant spec.)", "R.C.C Footings (as per approved drawings & consultant spec.)" ] }, "column_concrete": { "unit": "m3", "count": 15, "min": 2.0, "max": 50.0, "median": 21.0, "mean": 22.53, "stdev": 15.99, "values": [ 2.0, 4.0, 6.0, 6.0, 13.0, 13.0, 14.0, 21.0, 25.0, 28.0, 30.0, 38.0, 43.0, 45.0, 50.0 ], "samples": [ "R.C.C for Neck40 Columns (as per approved drawings & levels)", "R.C.C columns", "R.C.C columns" ] }, "tie_beam_concrete": { "unit": "m3", "count": 11, "min": 4.0, "max": 31.0, "median": 22.0, "mean": 18.36, "stdev": 8.57, "values": [ 4.0, 9.0, 9.0, 12.0, 18.0, 22.0, 24.0, 24.0, 24.0, 25.0, 31.0 ], "samples": [ "R.C.C for TIE Beams & Strap beams", "R.C.C for TIE Beams", "R.C.C for TIE Beams" ] }, "solid_block": { "unit": "m2", "count": 20, "min": 75.0, "max": 600.0, "median": 207.5, "mean": 267.6, "stdev": 182.79, "values": [ 75.0, 75.0, 95.0, 100.0, 110.0, 120.0, 120.0, 145.0, 150.0, 150.0, 265.0, 265.0, 295.0, 300.0, 430.0, 475.0, 484.0, 500.0, 598.0, 600.0 ], "samples": [ "20cm Solid Block Work under external tie beams & steps", "Insulated 20cm block work (for external walls)", "20cm Solid Block Work (For villa , U.G.W.T)" ] }, "wall_footing": { "unit": "m3", "count": 8, "min": 2.0, "max": 16.0, "median": 3.5, "mean": 4.88, "stdev": 4.61, "values": [ 2.0, 2.0, 3.0, 3.0, 4.0, 4.0, 5.0, 16.0 ], "samples": [ "WALL FOOTING (as per drawings locations & sections)", "WALL FOOTING", "WALL FOOTING" ] }, "slab_on_grade": { "unit": "m3", "count": 11, "min": 12.0, "max": 45.0, "median": 24.0, "mean": 23.91, "stdev": 9.58, "values": [ 12.0, 12.0, 18.0, 19.0, 19.0, 24.0, 26.0, 27.0, 29.0, 32.0, 45.0 ], "samples": [ "10cm thick slab on grade with A252 mesh", "10cm thick slab on grade with A252 mesh", "10cm thick slab on grade with A252 mesh" ] }, "staircase_concrete": { "unit": "m3", "count": 40, "min": 1.0, "max": 70.8, "median": 9.5, "mean": 17.25, "stdev": 18.7, "values": [ 1.0, 1.0, 3.0, 3.0, 3.0, 3.0, 4.0, 4.0, 4.0, 4.0, 5.0, 5.0, 5.0, 5.0, 5.0, 5.0, 6.0, 7.0, 9.0, 9.0, 10.0, 11.0, 12.0, 14.0, 14.0, 15.0, 15.0, 15.0, 15.0, 25.0, 30.0, 32.0, 33.0, 33.0, 35.0, 39.0, 56.0, 56.0, 68.0, 70.8 ], "samples": [ "R.C.C for Staircase", "marble staircase landing ((supply rate 100 DHS.)", "marble staircase steps (supply rate 100 DHS.)" ] }, "parapet": { "unit": "m3", "count": 11, "min": 4.0, "max": 23.0, "median": 6.0, "mean": 8.91, "stdev": 7.08, "values": [ 4.0, 4.0, 4.0, 5.0, 6.0, 6.0, 6.0, 6.0, 12.0, 22.0, 23.0 ], "samples": [ "R.C.C for Parapet (OR coping beam)", "R.C.C for Parapet (coping beam)", "R.C.C for Parapet (coping beam)" ] }, "internal_block": { "unit": "m2", "count": 24, "min": 22.0, "max": 570.0, "median": 217.5, "mean": 243.83, "stdev": 150.46, "values": [ 22.0, 24.0, 68.0, 110.0, 118.0, 160.0, 165.0, 165.0, 170.0, 200.0, 210.0, 210.0, 225.0, 225.0, 260.0, 265.0, 275.0, 310.0, 310.0, 315.0, 370.0, 540.0, 565.0, 570.0 ], "samples": [ "20cm Hollow block (for internal walls & parapt as per th dra", "10cm Hollow block (for internal walls & parapt as per drawi", "20cm Hollow block (for internal walLs & parapet as per the d" ] }, "granite": { "unit": "m2", "count": 23, "min": 15.0, "max": 105.0, "median": 32.0, "mean": 40.87, "stdev": 25.26, "values": [ 15.0, 18.0, 20.0, 20.0, 22.0, 22.0, 23.0, 30.0, 30.0, 30.0, 30.0, 32.0, 35.0, 38.0, 38.0, 38.0, 40.0, 48.0, 65.0, 68.0, 68.0, 105.0, 105.0 ], "samples": [ "Granite entrance front , back side & sitting (supply rate 1", "Granite steps (supply rate 100 DHS.)", "Granite skirting (supply rate 25 DHS.)" ] }, "marble": { "unit": "rm", "count": 19, "min": 13.0, "max": 73.0, "median": 22.0, "mean": 24.95, "stdev": 13.75, "values": [ 13.0, 13.0, 13.0, 13.0, 15.0, 18.0, 18.0, 20.0, 21.0, 22.0, 24.0, 25.0, 26.0, 30.0, 30.0, 30.0, 35.0, 35.0, 73.0 ], "samples": [ "Marble treshhold (supply rate of 80 DHS.)", "Marble treshhold (supply rate 50 DHS.)", "Marble treshhold (supply rate 50 DHS.)" ] }, "wall_tiles": { "unit": "m2", "count": 12, "min": 170.0, "max": 800.0, "median": 336.5, "mean": 376.92, "stdev": 153.9, "values": [ 170.0, 295.0, 295.0, 310.0, 310.0, 333.0, 340.0, 360.0, 400.0, 450.0, 460.0, 800.0 ], "samples": [ "ceramic wall tiles (supply rate 30 DHS.)", "ceramic wall tiles for all wet areas (supply rate 30 DHS.)", "ceramic wall tiles for all wet areas (supply rate 30 DHS.)" ] }, "skirting": { "unit": "rm", "count": 16, "min": 11.0, "max": 410.0, "median": 222.5, "mean": 223.81, "stdev": 126.24, "values": [ 11.0, 15.0, 50.0, 170.0, 170.0, 180.0, 180.0, 195.0, 250.0, 280.0, 290.0, 295.0, 315.0, 360.0, 410.0, 410.0 ], "samples": [ "ceramic skirting (supply rate 10 DHS.)", "Skirting for CERMIC (supply rate 10 DHS.)", "Skirting for CERMIC (supply rate 10 DHS.)" ] }, "door_openings": { "unit": "no.", "count": 24, "min": 1.0, "max": 28.0, "median": 12.0, "mean": 11.92, "stdev": 8.78, "values": [ 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 8.0, 9.0, 10.0, 10.0, 12.0, 12.0, 13.0, 14.0, 14.0, 19.0, 20.0, 20.0, 21.0, 21.0, 23.0, 25.0, 28.0 ], "samples": [ "Sub Frames For All Doors", "D (1) (supply rate of 8000. dhs / door)", "D (2) (supply rate of 3000 dhs / door)" ] }, "compound_wall": { "unit": "rm", "count": 11, "min": 32.0, "max": 132.0, "median": 111.0, "mean": 103.18, "stdev": 26.18, "values": [ 32.0, 84.0, 103.0, 110.0, 110.0, 111.0, 111.0, 112.0, 112.0, 118.0, 132.0 ], "samples": [ "ALL the civil work required for COMPOUND WALL", "ALL the civil work required for COMPOUND WALL", "ALL the civil work required for COMPOUND WALL" ] }, "interlock_paving": { "unit": "m2", "count": 11, "min": 150.0, "max": 940.0, "median": 351.0, "mean": 394.64, "stdev": 221.65, "values": [ 150.0, 215.0, 220.0, 300.0, 315.0, 351.0, 375.0, 375.0, 500.0, 600.0, 940.0 ], "samples": [ "Interlock work (supply rate of 25 DHS/SQM)", "Interlock work (supply rate of 25 DHS/SQM)", "Interlock work (supply rate of 25 DHS/SQM)" ] }, "polyethylene": { "unit": "sqm", "count": 7, "min": 210.0, "max": 585.0, "median": 450.0, "mean": 404.57, "stdev": 148.07, "values": [ 210.0, 210.0, 380.0, 450.0, 460.0, 537.0, 585.0 ], "samples": [ "Polythene sheet (1000 guage & as per consultant approval)", "Polythene sheet (1000 guage & as per consultant approval)", "Polythene sheet (1000 guage & as per consultant approval)" ] }, "neck_column_concrete": { "unit": "má¶¾", "count": 7, "min": 3.0, "max": 8.0, "median": 4.0, "mean": 4.43, "stdev": 1.72, "values": [ 3.0, 3.0, 4.0, 4.0, 4.0, 5.0, 8.0 ], "samples": [ "R.C.C for Neck Columns (as per drawings details & levels )", "R.C.C for Neck Columns (as per drawings details & levels )", "R.C.C for Neck Columns (as per approved drawings & levels)" ] }, "thermal_block": { "unit": "sqm", "count": 2, "min": 520.0, "max": 600.0, "median": 560.0, "mean": 560.0, "stdev": 0, "values": [ 520.0, 600.0 ], "samples": [ "25cm Thermal block (for External walLs as per th drawing)", "25cm Thermal block (for External walLs as per th drawing)" ] }, "window_openings": { "unit": "m2", "count": 3, "min": 108.0, "max": 325.0, "median": 200.0, "mean": 211.0, "stdev": 108.92, "values": [ 108.0, 200.0, 325.0 ], "samples": [ "Alminuim windows (supply of 600 0dhs per sqm)", "Alminuim windows (supply of 650dhs per sqm)", "Alminuim windows (supply of 550dhs per sqm)" ] } }