# Inference contract `engine` exposes `inspect(path)`, `classify(paths, progress=None)`, `infer(left_paths, right_paths, progress=None)`, and `status()`. The progress callback receives `(stage: str, detail: dict)`; detail includes `fraction`, `current`, and `total` when the amount of work is known. Importing the API and calling `status()` neither downloads nor loads a model. ## Provenance and loading The source is `MesserMMP/coronary-syntax-prediction` at the immutable revision in `manifest.json`. Ten complete R3D-18 + projected-LSTM checkpoints are used: five left and five right models, paired by fold. The artery classifier is a separate R3D-18. Safetensors are loaded strictly, after verifying their SHA-256 hash and expected size. Calibration is fetched from the same revision and its checksum and coefficients are also verified. No legacy pickle checkpoints, secondary weights repository, randomly initialized fallback, or incomplete ensemble is used. Set `SYNTAX_MODEL_CACHE` to a directory whose relative paths match the model repository. Missing files are fetched on demand. Set `SYNTAX_DEVICE=cpu` (default) or `cuda` on a compatible machine; `SYNTAX_CPU_THREADS` defaults to 2. Models run sequentially in float32 and are released after use. Only one projection's backbone activations are retained at a time, followed by the original LSTM over the ordered features. ## Input and preprocessing The supported input is an unsigned 8-bit or 16-bit, single-channel DICOM cine with 10–1024 frames and at most 512 MiB of decoded pixels. DICOM header dimensions must match the pixels. StudyInstanceUID and SOPInstanceUID must be retained. Mixed-study inputs and repeated SOPInstanceUIDs are rejected. Source files are read without modification. Returned metadata excludes patient names, patient identifiers, dates, institution names, and free-text DICOM fields. The score transform matches `full_model/rnn_dataset.py`: uint16 is scaled by the maximum value of the entire sequence to uint8; shorter-than-32-frame clips are doubled repeatedly, then the central 32 frames are selected. Grayscale is replicated into RGB, scaled to [0, 1], bilinearly resized to 256×256 with antialiasing, and normalized with ImageNet mean and standard deviation. Windowing, rescale, and MONOCHROME1 inversion are not applied because the published pipeline reads `pixel_array` directly. Unsupported signed, color, or single-frame input is rejected instead of being silently reinterpreted. Within each artery, input order is retained exactly. The LSTM is order-sensitive, so filename sorting would change predictions. To reproduce an evaluation study, pass the paths in `videos_left` and `videos_right` order. ## Artery assignment The classifier uses all original frames, RGB grayscale at 224×224, bilinear tensor resizing with `antialias=False`, and ImageNet normalization. `probability_right` is sigmoid of its one output: left is ≤0.1, right is ≥0.9, and values between these thresholds are unassigned in the engine output. The service automatically excludes these uncertain projections from scoring. This is artery probability, not confidence in a SYNTAX estimate. Only classifier-determined left/right lists reach `infer`; users cannot override assignments or projection order. The antialias setting is explicit because torchvision changed its unspecified default in version 0.17. The archived Philips probabilities are reproduced by `False`; the recently repaired Siemens examples were classified with `True`. All artery groups in the two verification studies agree under both settings, but their probabilities differ. This does not guarantee identical grouping for every possible input. Published examples cache verified GPU classifier outputs and ensemble results computed with those assignments. The score model separately uses `antialias=True`, as explicitly specified by its reference inference code. See the [official Resize documentation](https://docs.pytorch.org/vision/0.21/generated/torchvision.transforms.Resize.html). For long sequences, classifier convolution uses temporal tiles with 56-frame context on either side, aligned to the final temporal stride of 8. R3D-18 has a 109-frame temporal receptive field. Disjoint final feature positions are averaged once, so all original frames contribute without subsampling. Minor floating-point differences relative to one large batch are expected. ## Scores and calibration Each artery model's second output is log(1 + artery SYNTAX). Its score is `float(torch.exp(output)) - 1`. The first output is an artery-specific binary logit and is not exposed as a total disease probability. For fold i, calculate `raw_i = left_i + right_i` and `calibrated_i = a_i * raw_i + b_i`. Average each of those five values, then clip only the final study score at zero. Do not clip artery/fold intermediate values, apply calibration separately to arteries, or calibrate an ensemble mean with averaged coefficients. The returned `per_fold` values preserve the unclipped intermediates for reproducibility. If a side is absent, its score is `null` and both study totals are `null` with `complete=false`. The present side can still be inspected. The original batch evaluation represented missing sides by zero; this interactive service instead makes incompleteness explicit, because absence of an artery view does not show that the artery has no disease. ## Validation Run `python -m unittest engine.test_engine -v` for offline transform, tiling, architecture, calibration, and checkpoint-integrity checks. `python -m engine.validate_reference --help` describes the optional real-data check. It compares explicit JSON grouping/order to archived evaluation results, and can execute the original source model and dataset on CPU for an independent batched comparison. It does not download or alter input studies.