--- title: Umbilici emoji: 🩻 colorFrom: blue colorTo: gray sdk: static app_file: index.html pinned: false license: apache-2.0 short_description: Center lines of 35 Herculaneum scans, in live X-ray CT tags: - vesuvius-challenge - herculaneum - computed-tomography - umbilicus - three.js datasets: - SharpMeow/vesuvius-center-lines - SharpMeow/pherc0175a-lasagna --- # Umbilici A carbonized Herculaneum scroll is a sheet of papyrus wound around a center. Its center line, the umbilicus, is where tracing tools such as VC3D and villa's lasagna start. This page draws every public center line we know of for the 22 scans on the [Vesuvius Challenge prize page](https://scrollprize.org/prizes) (the 21 First Letters volumes and PHerc1447, read 23 October 2026) and for 13 other public scans that are not on the prize page (11 since 1.8.0, PHerc1667 and PHerc0172 since 1.10.0), over X-ray CT that your browser streams from the open data. Since 1.9.0 it also draws the coverage-polished Center Finder lines (twelve from dataset release v2.4, three more on 2.4 µm scans from v2.6) as the newest version of each line, with the original kept and drawn faded as superseded (the dataset's superseded_by). Since 1.10.0 the lines come from center lines v2.6.1: 57 lines on 35 scans. - **Array**: every scan's lines side by side, heights to scale in millimeters: the prize scans in the front two rows (people's lines, then the Center Finder's), the other public scans in the back row. Each maker has its own color (Vesuvius Challenge cyan, Alexey Drobkov pink, Abd Elilah violet, Iyan Dopico white, Chase Hendrick's Center Finder amber, its polished lines lime); click a maker in the key to hide its lines, or untick one line on a scan card, and the view link keeps it (`off=`). Scan names follow a traffic light from the automatic CT end check: green when both Center Finder ends passed, yellow for caution (a CT recap, an end it could not judge, or a 2.4 µm scan it was never tuned on), red when an end was flagged. The slider exaggerates side-to-side drift (default 2x). Reset returns it to 2x; an explicit `?ex=` link can select another value. This display setting does not change the published line coordinates. - **X-ray**: one scan. A radiograph (or maximum intensity) render of the whole scan at about 0.3 mm per voxel (0.15 to 0.23 mm on a 2.4 µm scan, with fewer heights), the lines inside it, and an axial slice at 70 to 80 µm per pixel with every line's crossing marked. The slice follows its height slider live (from the 0.3 mm CT already loaded, then sharpens when the slider rests), can turn with the 3D view ("turn with view"), and can be hidden and brought back from the bottom right. In X-ray and Lasagna the scan list steps aside and the menu next to the scan's name on its card opens another scan, so one panel scrolls at a time (the list, the card, or an open dialog); the page itself never scrolls. - **Lasagna**: PHerc0175A with villa's lasagna field: its sheet channel (cos) at nine heights, its surface normals as short needles colored by orientation, and the Center Finder's line through them. - **Data**: every number on the page as sortable tables (57 lines, 35 scans), with `lines.csv`, `scans.csv`, `points.csv` and `umbilici.json` downloads. - **Guide**: six tabs for every level of reader: Start here, VC3D and villa, For researchers (every statistic defined), Data details (frames, pyramids, encodings), Connect your tool and Credits. Each scan card has, per line, a download link and a copyable URL for the raw file, its sha256, license, upstream and every statistic; the scan's OME-Zarr URL and CT pyramid; each line's x, y, z at the slice you are on; a link that reopens the exact view; and the scan's points as CSV or JSON. ## Where the lines come from | Source | Scans | License | | --- | --- | --- | | Alexey Drobkov ([herculaneum-umbilici](https://github.com/AlexeyDrobkovStrikesBack/herculaneum-umbilici)) | 10 | MIT | | Abd Elilah, manual curves ([umbilicus-cross-validation](https://github.com/TAUIL-Abd-Elilah/umbilicus-cross-validation)) | 6 | CC BY 4.0 | | Iyan Dopico (PHerc1218, as shipped in Drobkov's repository) | 1 | MIT | | Vesuvius Challenge open data (`representations/umbilicus`) | 7 (4 not on the prize page) | CC BY-NC 4.0 | | Chase Hendrick's Center Finder (model output) | 18 (9 not on the prize page) | CC BY-NC 4.0 | | Chase Hendrick's Center Finder, polished (model output) | 15 (6 not on the prize page) | CC BY-NC 4.0 | Every file, with its hash, upstream link and note, is in [SharpMeow/vesuvius-center-lines](https://huggingface.co/datasets/SharpMeow/vesuvius-center-lines). Abd Elilah's PHerc1203 curve is drawn gray and labeled unused: its author withdrew it from recommended use (repository README, 16 Aug 2026). The 18 Center Finder lines are model output, made for the scans that had no person's line: nine 1.2 m prize scans, then (dataset release v2.3, 24 Oct 2026) PHerc0343, PHerc0814 and PHerc0841 at 1.2 m and PHerc1299, PHercMAN5, PHercMANB and PHercParis3 at 2.4 µm, then (v2.6, 25 Oct 2026) PHerc1667 at 2.4 µm and PHerc0172 at 7.91 µm. No person has checked their ends on CT. An automatic CT end check compares each end with the scroll center the CT shows there, estimated from the scan alone, with a 4 mm bar. On the nine prize lines (v2.2, 23 Oct 2026) 14 of the 18 ends pass and 4 are flagged (PHerc0175B high, PHerc0306B low, PHerc0490B low, PHerc0846A high); five passing ends are marked CT recap: their last 10 mm was replaced by a straight fit to the CT, so the pass says the CT supports that end. On the seven v2.3 lines all 14 ends pass, 2 after a CT recap (PHerc0343 low, PHercMANB high); the check was tuned only on 1.2 m scans, so its grades on the four 2.4 µm scans are marked untested and no end there is called usable. On the two v2.6 lines, PHerc1667's ends both pass (untested, a 2.4 µm scan) and PHerc0172's are both flagged, so treat its ends with care. The page shows the grade per line and per end on its card. Model output: no end has been checked on CT by a person. Each line's card says which ends are usable. The 15 polished lines are the Center Finder's lines moved by Scrolls `kit axispolish` (rule 1) toward where villa's predicted sheet winds most: twelve on 1.2 m scans (dataset release v2.4, 24 Oct 2026) and three on 2.4 µm scans, PHerc1299, PHercMAN5 and PHercMANB (v2.6, 25 Oct 2026), where the polish ran on level 2 and is untested. On all ten scans of a frozen test the 1.2 m polished lines sat deeper in villa's traced sheet than the line before the polish (winding coverage on villa's model output, not distance to the true axis; PHerc0343 and PHerc0846A were not in it), and Scrolls kit takes them first. They are jumpier than the originals and their ends were not re-checked, so the scan's grade stays the original line's. Each card marks the newest version NEWEST and the older one SUPERSEDED; the older one is drawn gray and labeled unused. ## Using the lines in VC3D and villa Each file is JSON with `control_points`, a list of `{x, y, z}` in the level-0 voxels of the scan it names. From villa's source (`main`, read 23 Oct 2026): - VC3D ([`volume-cartographer/core/src/Umbilicus.cpp`](https://github.com/ScrollPrize/villa/blob/main/volume-cartographer/core/src/Umbilicus.cpp)) reads a bare array of points or an object with `points` or `control_points`, each point with x, y and z, and an optional `metadata` block with `voxelsize_um`, `volume` and the grid `volume_width`, `volume_height`, `volume_slices` (all three or none). 50 of the 57 files carry that stamp, matching their scan's grid; Abd Elilah's six and Iyan Dopico's are bare points. VC3D interpolates linearly between points and holds the end points' x and y beyond them. - spiral-fitting ([`spiral-fitting/umbilicus.py`](https://github.com/ScrollPrize/villa/blob/main/spiral-fitting/umbilicus.py)) sorts `control_points` by z, multiplies x, y and z by `coordinate_scale` (or 1/`downsample_factor`), ignores `metadata` and extrapolates linearly past both ends. A fit on pyramid level L needs a scale of 1/2^L. - villa's [spiral tutorial](https://scrollprize.org/tutorial_spiral) (last updated 16 Sep 2026): `fit_spiral.py` reads `umbilicus.json` from its `--dataset` root, beside `lasagna_inputs/*.ome.zarr`; `infer_winding_volume.py` takes `--umbilicus`; every input must be in the fit's own voxel frame. Because VC3D holds the ends and spiral-fitting extrapolates them, check a line's usable ends before relying on it near the top or bottom of a scan. ## One glowing line per scan Since 1.14.0 only one line per scan glows: its best line, the one Scrolls `kit centerline get` and AutoPipeline take by default (`order()` in `kit/centerline.py`). That is a person's or the organizers' line where the scan has one, ranked the organizers' first and then the makers by name, otherwise the newest Center Finder line; a withdrawn line counts as an old version. Every other line is drawn gray and thinner, without glow, and gets a role: **alternate**, a current line the default passes over, or **unused**, an older version (superseded) or a withdrawn line. The role is on each scan card (BEST, ALTERNATE, UNUSED, best first), in the scan list (the best line's chip first, the others gray), in the Data tables (`role` per line, `best line` per scan), in the `lines.csv`, `points.csv` and `umbilici.json` downloads, and in `lines()`, `at()` and `best()` for agents. Best means first in that order, not checked against the CT: no person has compared the lines on a scan. ## Ends outside the scroll Since 1.13.0 each line is drawn from its first to its last point inside the scroll. `tools/build_lines.py` tests every line's end points against the scan's masked CT at level 5 (32 times down; voxels outside the scroll are zero): a point lies outside when, in its own axial slice, it sits more than 4 mm outside the scroll's outline (the convex hull of the nonzero voxels) or the slice holds no scroll at all. At each end the hidden run reaches from the end to the innermost outside point among the outer quarter of the line's points; the middle half is never hidden. Two checks make the test able to fail: the line's middle point must be inside and the slice corner farthest from it outside, or the line is drawn whole and marked untested. Each card says per end how many points are hidden and how far past the scroll they lie, the Data tables have `low out` and `high out` columns, and the drift statistics (mean, stray, tilt, wiggle, path, pair gaps) use the inside part. **show ends outside the scroll** at bottom left (`outside=1` in the view link) draws the hidden runs faded and dotted. Some Center Finder v2 lines run tens of mm sideways at an end, where their start line was never trimmed to the papyrus; their files are unchanged here, and the downloads, `lines()` and the copied URLs keep every point. ## X-ray CT is not stored on this Space. Each visitor's browser reads coarse levels of the OME-Zarr volumes straight from the Vesuvius Challenge open-data bucket with HTTP range requests: one axial plane of each 128-voxel chunk at a time, about 1,000 small reads for a whole-scan render and 25 to 100 for a slice. The radiograph adds up CT along each ray, like a film X-ray. One scan is the exception: PHerc0172's 7.91 µm scan is stored Blosc-compressed, so a chunk cannot be read one plane at a time, and the page draws its line without CT (its card says so, and links it in neuroglancer, which reads compressed chunks). Scans: Vesuvius Challenge open data, CC BY-NC 4.0. ## Lasagna field villa's lasagna `predict3d` over the whole PHerc0175A scan (ScrollPrize/villa db3dbea2, model `scrollprize/lasagna` de45f011), from [SharpMeow/pherc0175a-lasagna](https://huggingface.co/datasets/SharpMeow/pherc0175a-lasagna). This page ships a small derivative in `data/lasagna/`, made by `tools/build_lasagna.py`: the cos channel at nine heights (4x down, resized to 2048 px), an orientation picture per height (hue from the doubled in-plane angle of the normal, so a normal and its opposite match) and 155,891 normals on a 96 by 96 by 192 voxel grid. It is model output, shown so people can see what the dataset holds. ## For agents The page is driven from the console or a headless browser through `window.umbilici`: | Call | Returns or does | | --- | --- | | `scans()` | every scan: scroll, scan id, volume, voxel size, shape, prize lists, sources, best (the source of its best line), end grade | | `lines(scroll)` | that scan's lines with control points `[x, y, z]` in level-0 voxels, every point of the file, `role` (`best`, `alternate` or `unused`) and `outside` (points hidden at each end, or null with `outside_why`) | | `at(scroll, z)` | each line's `[x, y]` at height `z` (linear between control points) and its `role` | | `best(scroll)` | that scan's best line (the glowing one, the line kit takes by default) with its points, or null | | `select(scroll, mode)`, `mode('array' or 'scan' or 'lasagna')`, `setZ(z)` | change the view | | `state()` | mode, scan, height, whether the ends outside the scroll are shown, CT streaming progress | | `outside(on)` | shows (`true`) or hides (`false`) the line ends that lie outside the scroll in the CT, omitted toggles; returns `{outside}`, also kept in the URL as `outside=1` | | `image()`, `slice()` | PNG data URLs of the 3D view and the slice | | `stats(scroll)` | every statistic of each line (points, z range, coverage, steps, points hidden at each end, stray, tilt, wiggle, path, stamp; the drift statistics on the inside part) and the pair gaps | | `table('lines' or 'scans')`, `csv('lines' or 'scans' or 'points')` | the Data tables as objects or CSV text | | `guide(tab)`, `data(tab)` | open the guide (`basics`, `vc3d`, `research`, `data`, `credits`) or the Data tables | | `bench(n)` | renders `n` frames and returns milliseconds per frame and the pixel ratio | | `show(kind, name, on)` | shows or hides lines: `kind` `'source'` with a maker (`bucket`, `drobkov`, `tauil`, `dopico`, `finder`, `finder-polished`, `finder-v2`) or `'line'` with `SCROLL:SOURCE`; `on` true or false, omitted toggles; returns `{off}`, also kept in the URL as `off=` | | `settings(obj)` | read or change the viewer settings: `glow` (0 to 3), `radius` (0 to 1), `quality` (`auto`, `high`, `low`), `film`, `spin`, `inset` (the slice panel shown), `turn` (the slice turns with the 3D view) | URL parameters: `?mode=scan&scan=PHerc0191&z=10400`, `?mode=lasagna&scan=PHerc0175A&z=6400`, `?ex=5`, `?outside=1`, `?guide=vc3d`, `?data=lines`, `?glow=1.5`. The gear button holds the settings (glow strength and spread, quality, film grain, spin), saved in the browser. `data/lines.json` is the line table built at deploy by `tools/build_lines.py` from a copy of the dataset. On load the page reads the dataset's newest revision from huggingface.co and shows it instead, so new releases appear without a redeploy; the built table is the fallback. ## License Code: Apache 2.0, Chase Hendrick (`LICENSE`, `NOTICE`); three.js is MIT. Data keeps its own terms (`NOTICE`). A sibling of [Unroll](https://huggingface.co/spaces/SharpMeow/unroll). A center line is geometry; nothing here is a reading of any text.