from app.models.parallel import PumpGroupParallelModel from app.models.pump_curve import PumpCurveModel Q = [0, 40, 80, 120, 150, 180, 210] H = [58.0, 56.5, 53.0, 47.0, 42.5, 36.0, 27.0] E = [0.0, 0.42, 0.66, 0.79, 0.82, 0.78, 0.66] def make_group(n=3): pumps = {i: PumpCurveModel(i, Q, H, E) for i in range(1, n + 1)} return PumpGroupParallelModel(pumps, static_head=12.0, pipe_resistance=2.6e-4) def test_operating_point_on_system_curve(): g = make_group() op = g.solve({1: 45.0}) # 工作点必须落在系统曲线上:H ≈ Hst + S·Q² assert abs(op.H - g.system_head(op.Q_total)) < 0.5 assert op.Q_total > 0 and op.P_total > 0 assert op.spec_energy > 0 def test_more_pumps_more_flow(): g = make_group() q1 = g.solve({1: 50.0}).Q_total q2 = g.solve({1: 50.0, 2: 50.0}).Q_total # 并联加泵总流量增加,但因管阻非线性并非线性翻倍 assert q2 > q1 assert q2 < 2 * q1 def test_empty_active(): g = make_group() op = g.solve({}) assert op.Q_total == 0.0 and op.P_total == 0.0 def test_lower_freq_lower_flow(): g = make_group() assert g.solve({1: 30.0}).Q_total < g.solve({1: 50.0}).Q_total def test_level_dependent_static_head(): # 无出口压力表:扬程由液位估计。液位越低静扬程越大、扬程越高、流量越小。 pumps = {i: PumpCurveModel(i, Q, H, E) for i in (1,)} g = PumpGroupParallelModel(pumps, static_head=12.0, pipe_resistance=2.0e-3, level_ref=5.5) assert abs(g.static_at(5.5) - 12.0) < 1e-9 # 参考液位处 = static_head assert g.static_at(3.5) > g.static_at(7.5) # 低液位静扬程更大 op_low = g.solve({1: 50.0}, level=3.5) # 低液位 op_high = g.solve({1: 50.0}, level=7.5) # 高液位 assert op_low.H > op_high.H # 低液位扬程更高 assert op_low.Q_total < op_high.Q_total # 低液位流量更小 assert g.static_at(None) == 12.0 # 不给液位则用固定静扬程 def test_infeasible_when_pump_cannot_reach_static_head(): pump = PumpCurveModel(1, [0, 100], [5, 3], [0.5, 0.7]) group = PumpGroupParallelModel({1: pump}, static_head=12.0, pipe_resistance=1e-5) op = group.solve({1: 50.0}) assert not op.feasible assert op.reason == "pump_head_below_static_head" assert op.Q_total == 0.0