"""Device model: geometry + current crowding + material -> one result. This is the only place where the three other modules come together, so it is the place to add new output quantities. """ from __future__ import annotations import math from typing import Literal, Optional import numpy as np from pydantic import BaseModel, Field from . import geometry, gibbs, operating, physics from .materials import DerivedMaterial, Material, derive LOAD_OHM = 50.0 # readout impedance used for the reset-time estimate class DesignRequest(BaseModel): """User inputs of one design.""" width_nm: float = Field(100, gt=0, le=1e5, description="Wire width W.") gap_nm: float = Field(200, gt=0, le=1e6, description="Spacing between wires g.") run_length_um: float = Field(10, gt=0, le=1e4, description="Length of each straight run.") n_runs: int = Field(11, ge=1, le=2000, description="Number of parallel runs.") terminals: Literal["straight", "optimal_90"] = "straight" temperature_K: Optional[float] = Field( None, ge=0, le=300, description="Operating temperature. None: material values as given." ) bias_fraction: float = Field(0.9, gt=0, le=1, description="Bias current / device Ic.") series_resistance_ohm: float = Field( 0, ge=0, le=1e5, description="Resistor in series with the 50 ohm readout." ) substrate_index: float = Field(1.75, ge=1, le=5, description="Refractive index of substrate.") material_id: Optional[str] = None material: Optional[Material] = Field( None, description="Inline material. Used when material_id is not given." ) def spec(self, xi_nm: float | None = None) -> geometry.SnakeSpec: """Geometry inputs. ``xi_nm`` is necessary for the optimised bend.""" return geometry.SnakeSpec( width=self.width_nm * 1e-3, gap=self.gap_nm * 1e-3, run_length=self.run_length_um, n_runs=self.n_runs, terminals=self.terminals, xi=(xi_nm or 0.0) * 1e-3, ) class BendResult(BaseModel): """Current crowding of one type of bend.""" kind: str count: int crowding: float # peak K / K_I at the inner edge (1 = none) min_radius_nm: Optional[float] reduction: float # R = Ic(bend) / Ic(straight) equation: str class OperatingResult(BaseModel): """Estimates at the operating temperature (``None`` = input not available).""" temperature_K: Optional[float] xi_nm: float lambda_nm: Optional[float] Lk_pH_sq: Optional[float] Idep_uA: Optional[float] # depairing current of the straight wire Ic_over_Idep: Optional[float] # device Ic / Idep ("constriction factor") width_over_xi: float vortex_fits: bool # W > 4.4 xi (Likharev) absorptance: Optional[float] bias_uA: Optional[float] pulse_mV: Optional[float] reset_time_ns: Optional[float] load_ohm: float dark_count_exponent: Optional[float] current_step_for_10x_dcr: Optional[float] # relative change of I retrapping_uA: Optional[float] thermal_time_ps: Optional[float] latching: str class DesignResult(BaseModel): # geometry pitch_nm: float fill_factor: float optimal_gap_nm: float size_um: tuple[float, float] active_area_um2: float film_area_um2: float wire_length_um: float squares: float # crowding bends: list[BendResult] reduction: float limiting_bend: str sharp_reference: list[BendResult] # electrical material: Material derived: DerivedMaterial operating: OperatingResult Ic_straight_uA: Optional[float] Ic_origin: str Ic_device_uA: Optional[float] Ic_theory_uA: Optional[float] resistance_kohm: Optional[float] Lk_total_nH: Optional[float] reset_time_ns: Optional[float] # plot data and messages reduction_bound_xi: float first_bend_um: Optional[list[float]] reduction_curve: dict[str, list[Optional[float]]] warnings: list[str] polygons: list[list[list[float]]] def _optimised(w: float, g: float, xi: float) -> BendResult: edge = gibbs.inner_edge(gibbs.optimise(w, g, xi)) return BendResult( kind="180-degree bend, optimised", count=0, crowding=edge.peak_k, min_radius_nm=None, reduction=min(1.0, edge.reduction), equation="Gibbs energy, Eq. (7)-(11), all shapes", ) def _contour(w: float, g: float, xi: float) -> BendResult: optimal = g >= 2 * w * (1 - 1e-6) return BendResult( kind="180-degree optimal bend" if optimal else "180-degree bend, streamline contour", count=0, crowding=physics.hairpin_crowding(w, g), min_radius_nm=physics.hairpin_min_radius(w, g), reduction=physics.reduction_rounded_hairpin(w, g, xi), equation="Eq. (58)" if optimal else "Eq. (62), (63)", ) #: Bend shape (``SnakeSpec.shape``) -> model. BEND_MODELS = {"optimised": _optimised, "contour": _contour} def bend_results(req: DesignRequest, xi_nm: float) -> list[BendResult]: """Current crowding of the bends that are in the design.""" w, g = req.width_nm, req.gap_nm out = [] if req.n_runs > 1: bend = BEND_MODELS[req.spec(xi_nm).shape](w, g, xi_nm) bend.count = req.n_runs - 1 out.append(bend) if req.terminals == "optimal_90": out.append( BendResult( kind="90-degree optimal bend", count=2, crowding=1.0, min_radius_nm=physics.OPTIMAL_90_MIN_RADIUS_FACTOR * w, reduction=physics.reduction_optimal_90(w, xi_nm), equation="Eq. (111)", ) ) return out def _sharp_turn(w: float, g: float, xi: float) -> tuple[float, str]: """R of the sharp rectangular turn, and its origin. In the range of ``gibbs.py`` the same model as for the optimised bend is used, so that the two can be compared. Else: the paper's Eq. (100). """ if gibbs.XI_RANGE[0] <= xi / w <= gibbs.XI_RANGE[1] and g / w >= gibbs.RATIO_RANGE[0]: return gibbs.reduction_sharp_turn( w, g, xi ), "Gibbs energy, same model (Eq. 100 for xi << W)" return physics.reduction_sharp_rect_hairpin(w, g, xi), "Eq. (100)" def sharp_reference(req: DesignRequest, xi_nm: float) -> list[BendResult]: """R of sharp corners with the same width and gap, for comparison.""" w, g = req.width_nm, req.gap_nm sharp, origin = _sharp_turn(w, g, xi_nm) return [ BendResult( kind="Sharp rectangular 180-degree turn", count=0, crowding=math.inf, min_radius_nm=0.0, reduction=sharp, equation=origin, ), BendResult( kind="Sharp 90-degree corner", count=0, crowding=math.inf, min_radius_nm=0.0, reduction=physics.reduction_sharp_90(w, xi_nm), equation="Eq. (108)", ), ] def reduction_curve(width_nm: float, xi_nm: float, n: int = 60) -> dict[str, list]: """R against gap / width: optimised bend, sharp turn, and the estimate of the largest R of all shapes.""" ratio = np.linspace(0.1, 3.0, n) return { "gap_over_width": ratio.tolist(), "optimised": gibbs.reduction_curve(ratio.tolist(), xi_nm / width_nm), "sharp": [_sharp_turn(width_nm, r * width_nm, xi_nm)[0] for r in ratio], "bound_xi": [gibbs.reduction_bound(width_nm, r * width_nm, xi_nm) for r in ratio], } def _warnings( req: DesignRequest, mat: Material, derived: DerivedMaterial, xi: float, lambda_nm: Optional[float], ) -> list[str]: """Cautions. ``xi`` and ``lambda_nm`` are the values at the operating temperature.""" w, g = req.width_nm, req.gap_nm out = [] if req.n_runs > 1 and g < 2 * w * (1 - 1e-9): out.append( f"Spacing is smaller than 2 x width ({2 * w:g} nm). A bend without current " "crowding is not possible at constant pitch." ) if req.spec(xi).shape != "optimised": out.append( "The optimiser is not valid for these inputs (it needs 0.005 <= xi/W <= 0.15 " "and 0.05 <= g/W <= 1.98). The streamline contour of phidl is used. " "It is not the best shape." ) if w < 5 * xi: out.append(f"Width is only {w / xi:.1f} x xi. The model is accurate for xi << width.") if req.n_runs > 1 and g < 10 * xi: out.append("Spacing is not much larger than xi. The model is less accurate.") pearl_um = 2 * lambda_nm**2 / mat.thickness_nm * 1e-3 if lambda_nm else None if pearl_um and w * 1e-3 > 0.1 * pearl_um: out.append( "Width is not much smaller than the Pearl length " f"({pearl_um:.1f} um). The uniform-current model is less accurate." ) if w <= operating.LIKHAREV_FACTOR * xi: out.append( f"Width is smaller than 4.4 x xi = {operating.LIKHAREV_FACTOR * xi:.0f} nm: a vortex " "does not fit in the wire. The vortex-entry model for R and the dark-count " "exponent do not apply." ) if derived.lambda_nm is None and mat.jc_MA_cm2 is None: out.append( "No lambda, Lk, (Rs and Tc), or jc for this material: " "the critical current cannot be calculated. R is still correct." ) return out def _reduced_temperature(req: DesignRequest, mat: Material) -> float: """t = T / Tc; 0 when no temperature is given.""" if req.temperature_K is None: return 0.0 if not mat.Tc_K: raise ValueError("This material has no Tc: an operating temperature cannot be used") if req.temperature_K >= mat.Tc_K: raise ValueError( f"Operating temperature {req.temperature_K:g} K is not lower than Tc = {mat.Tc_K:g} K" ) return req.temperature_K / mat.Tc_K def _operating( req: DesignRequest, mat: Material, t: float, xi_nm: float, lambda_nm: Optional[float], lk_pH_sq: Optional[float], squares: float, ic_device_uA: Optional[float], ) -> OperatingResult: """Detector estimates. Each one is ``None`` if an input is not available.""" w = req.width_nm * 1e-9 d = mat.thickness_nm * 1e-9 temp = req.temperature_K diffusion = mat.D_cm2_s * 1e-4 if mat.D_cm2_s else None load = LOAD_OHM + req.series_resistance_ohm idep = None if mat.Rs_ohm_sq and mat.Tc_K and diffusion: idep = operating.depairing_current(mat.Rs_ohm_sq, mat.Tc_K, diffusion, w, t) * 1e6 bias = ic_device_uA * req.bias_fraction if ic_device_uA else None nu = None if lambda_nm and temp: nu = operating.dark_count_exponent(lambda_nm * 1e-9, d, temp) retrap = tau_th = None latching = "not available (no thermal conductance, Rs or Tc)" if mat.hc_W_m2K and mat.Rs_ohm_sq and mat.Tc_K and temp is not None: retrap = operating.retrapping_current(mat.Rs_ohm_sq, mat.Tc_K, w, mat.hc_W_m2K, temp) * 1e6 if diffusion: tau_th = ( operating.thermal_time(mat.Rs_ohm_sq, mat.Tc_K, d, diffusion, mat.hc_W_m2K) * 1e12 ) if bias is None: latching = "not available (no critical current)" elif bias <= retrap: latching = "not possible: bias is below the retrapping current" else: latching = "possible: bias is above the retrapping current" elif temp is None: latching = "not available (no operating temperature)" lk_total = lk_pH_sq * squares * 1e-3 if lk_pH_sq else None # nH return OperatingResult( temperature_K=temp, xi_nm=xi_nm, lambda_nm=lambda_nm, Lk_pH_sq=lk_pH_sq, Idep_uA=idep, Ic_over_Idep=ic_device_uA / idep if ic_device_uA and idep else None, width_over_xi=req.width_nm / xi_nm, vortex_fits=req.width_nm > operating.LIKHAREV_FACTOR * xi_nm, absorptance=( operating.absorptance( mat.Rs_ohm_sq, req.width_nm / (req.width_nm + req.gap_nm), req.substrate_index ) if mat.Rs_ohm_sq else None ), bias_uA=bias, pulse_mV=bias * LOAD_OHM * 1e-3 if bias else None, reset_time_ns=lk_total / load if lk_total else None, load_ohm=load, dark_count_exponent=nu, current_step_for_10x_dcr=math.log(10) / nu if nu else None, retrapping_uA=retrap, thermal_time_ps=tau_th, latching=latching, ) def evaluate(req: DesignRequest, mat: Material) -> DesignResult: """Calculate all outputs for one design and one material. With ``req.temperature_K`` the material values are changed to that temperature first (laws in ``operating.py``); R, the bend shape, Ic, the inductance and the reset time then use the changed values. """ derived = derive(mat) t = _reduced_temperature(req, mat) xi_nm = derived.xi_nm * operating.coherence_factor(t) lk_factor = operating.inductance_factor(t) lambda_nm = derived.lambda_nm * math.sqrt(lk_factor) if derived.lambda_nm else None lk_pH_sq = derived.Lk_pH_sq * lk_factor if derived.Lk_pH_sq else None spec = req.spec(xi_nm) device = geometry.build_snake(spec) (x0, y0), (x1, y1) = device.bbox squares = geometry.snake_squares(spec) bends = bend_results(req, xi_nm) limiting = min(bends, key=lambda b: b.reduction, default=None) reduction = limiting.reduction if limiting else 1.0 # Critical current of the straight wire. ic_theory = None if lambda_nm: kc = physics.critical_sheet_current(xi_nm * 1e-9, lambda_nm * 1e-9, mat.thickness_nm * 1e-9) ic_theory = kc * req.width_nm * 1e-9 * 1e6 # uA if mat.jc_MA_cm2: # MA/cm^2 = 1e10 A/m^2 ic_straight = mat.jc_MA_cm2 * 1e10 * req.width_nm * 1e-9 * mat.thickness_nm * 1e-9 * 1e6 ic_origin = "measured jc x width x thickness" same = mat.jc_temperature_K is not None and req.temperature_K == mat.jc_temperature_K if same: ic_origin += f" (measured at {mat.jc_temperature_K:g} K)" elif req.temperature_K is not None and mat.jc_temperature_K is not None and mat.Tc_K: t_meas = mat.jc_temperature_K / mat.Tc_K ic_straight *= operating.current_factor(t) / operating.current_factor(t_meas) ic_origin += ( f", changed from {mat.jc_temperature_K:g} K to {req.temperature_K:g} K " "with (1 - t^2)^(3/2)" ) elif req.temperature_K is not None: ic_origin += " (temperature of the measurement not known: not changed)" else: ic_straight = ic_theory ic_origin = "Eq. (14): phi0 W / (e pi mu0 xi Lambda)" if ic_theory else "not available" ic_device = ic_straight * reduction if ic_straight else None op = _operating(req, mat, t, xi_nm, lambda_nm, lk_pH_sq, squares, ic_device) lk_total = lk_pH_sq * squares * 1e-3 if lk_pH_sq else None # nH warnings = _warnings(req, mat, derived, xi_nm, lambda_nm) return DesignResult( pitch_nm=req.width_nm + req.gap_nm, fill_factor=req.width_nm / (req.width_nm + req.gap_nm), optimal_gap_nm=2 * req.width_nm, size_um=(x1 - x0, y1 - y0), active_area_um2=spec.run_length * (spec.n_runs * spec.pitch - spec.gap), film_area_um2=geometry.film_area(device), wire_length_um=squares * spec.width, squares=squares, bends=bends, reduction=reduction, limiting_bend=limiting.kind if limiting and reduction < 1 else "none (straight wire)", sharp_reference=sharp_reference(req, xi_nm), material=mat, derived=derived, operating=op, Ic_straight_uA=ic_straight, Ic_origin=ic_origin, Ic_device_uA=ic_device, Ic_theory_uA=ic_theory, resistance_kohm=mat.Rs_ohm_sq * squares * 1e-3 if mat.Rs_ohm_sq else None, Lk_total_nH=lk_total, reset_time_ns=op.reset_time_ns, reduction_bound_xi=gibbs.reduction_bound(req.width_nm, req.gap_nm, xi_nm), first_bend_um=device.info.get("first_bend"), reduction_curve=reduction_curve(req.width_nm, xi_nm), warnings=warnings, polygons=[np.round(p, 5).tolist() for p in geometry.polygons(device)], )