--- language: - en license: mit tags: - medical-imaging - chest-xray - pediatric-pneumonia - state-space-models - mamba - knowledge-distillation - reproducible-research datasets: - paultimothymooney/chest-xray-pneumonia pipeline_tag: image-classification --- # BioHCL-SSSM: Biologically-Gated Hybrid Convolutional Linear Selective State-Space Model (Audited Clean Release) **BioHCL-SSSM** (`unknownBrain/BioHCL-SSSM`) is a consolidated, leak-free, fully reproducible codebase and checkpoint archive for pediatric chest X-ray pneumonia classification (**Kermany et al., *Cell* 2018; `paultimothymooney/chest-xray-pneumonia`, `N = 5,856` JPEGs only**). Every architectural module, checkpoint, CSV log, bootstrap confidence interval, McNemar significance test, and scientific disclosure in this repository has been independently audited across multi-stage verification gates. For full methodology, calibration analysis, patient-grouping forensics, legacy artifact corrections, and complete tables, see [TECHNICAL_REPORT.md](TECHNICAL_REPORT.md). --- ## Key Verified Results ### 1. Held-Out Official Kermany Test Set (`N = 624`, Fixed Threshold `t = 0.50`, Strict FP32) | Model | Params (Trainable) | GMACs | Test Acc [95% CI] | Precision | Recall | Specificity | F1 | ROC-AUC | Brier | ECE (10-bin) | |---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:| | **Student BioHCL-SSSM (`256-d`, KD)** | **8,340,554** | **3.429** | **87.50%** [84.78, 90.06] | **83.62%** | 99.49% | 67.52% | **0.9087** | 0.9391 | 0.1218 | 0.1229 | | Baseline ResNet-50 | 23,512,130 | 4.132 | 84.29%* [81.41, 87.18] | 80.17% | 99.49% | 58.97% | 0.8879 | **0.9605** | 0.1481 | 0.1465 | | Ablation: Single-CNN Branch | 1,249,822 | 1.132 | 83.81% [80.93, 86.70] | 84.99% | 90.00% | **73.50%** | 0.8742 | 0.9116 | **0.1179** | **0.0467** | | Ablation: No Bio-Prior | 8,340,554 | 3.429 | 82.37% [79.33, 85.42] | 78.11% | 99.74% | 53.42% | 0.8761 | 0.9506 | 0.1701 | 0.1681 | | Ablation: No Positional Encoding | 8,340,554 | 3.417 | 81.09% [77.88, 84.13] | 76.88% | 99.74% | 50.00% | 0.8683 | 0.9701 | 0.1875 | 0.1879 | *\*`Baseline_ResNet50` scores `84.29%` (`526/624`) in strict FP32 and `84.46%` (`527/624`) under `torch.amp.autocast('cuda')` due to 1 borderline image (`p=0.5036` FP32). Paired McNemar exact test (`Student` vs `ResNet-50` FP32): `ΔAcc = +3.21% [+1.44%, +4.97%]`, `27` vs `7` discordant pairs, **`p = 0.000821`**.* ### 2. Clean Patient-Grouped 5-Fold Cross-Validation (`N = 5,232`, `2,861` Patient/MD5 Groups, Direct `256-d` `L=2`) Using **Union-Find patient + exact MD5 grouping BEFORE `StratifiedGroupKFold`** (`0` patient overlap, `0` MD5 overlap per fold; official `test/` untouched): - **Mean ± SD across 5 folds:** Accuracy **`99.35% ± 0.26%`**, Macro-F1 **`0.9915 ± 0.0032`**, F1 **`0.9956 ± 0.0017`**, Specificity **`99.11% ± 0.61%`**, Recall **`99.43% ± 0.21%`**, ROC-AUC **`0.9994 ± 0.0004`**, Brier **`0.0064 ± 0.0025`**, ECE **`0.0065 ± 0.0027`**. - **Pooled Out-Of-Fold (`N = 5,232`):** Accuracy **`99.35%` [99.12%, 99.56%]**, `TN = 1,337`, `FP = 12`, `FN = 22`, `TP = 3,861`, ROC-AUC `0.9991`, Brier `0.0064`, ECE `0.0061`. > **Central Generalization Gap Finding:** BioHCL-SSSM achieves **99.35% ± 0.26%** internal patient-grouped CV accuracy (`N=5,232`), demonstrating strong within-cohort generalization, while external transfer to the official held-out Kermany test set (`N=624`) yields **87.50%** (KD Student) and **80.61%–85.90%** across single-fold `λ_phys=0.0` direct runs (`78.69%–85.90%` across all `11` variants including regularized sweeps) — reflecting documented distribution shift (`train+val` 74.1% vs `test` 62.5% Pneumonia, acquisition/spectrum differences). We never conflate internal CV with external generalization. ### 3. Unified Controlled `256-d` Fold-0 Ablation Highlights (`--epochs 30 --patience 8`, 11 Variants) All `11` variants converged without single-class collapse (`WeightedRandomSampler` never stacked with weighted losses): - **SSSM vs. Tuned 8-Head MHSA:** `SSSM_L2_Ref` (`8.34M` params: `82.69%` Test Acc `[79.65, 85.58]`, `0.9588` AUC) vs. `MHSA_L2_8Heads` (`8.56M` params: `83.01%` Test Acc `[79.97, 85.90]`, `0.9482` AUC) perform within sampling noise on Fold 0 — no superiority claimed over MHSA without multi-fold testing. - **Depth & Skip Connections (Single-Fold):** `Depth_SSSM_L4` reached **`85.26%`** (`0.9708` AUC) and `Ablation_NoSkip_L2` reached **`84.62%`** (`0.9759` AUC), outperforming `SSSM_L2_Ref` (`82.69%`) on Fold 0 — reported transparently as single-fold observations requiring multi-fold validation. - **Class-Imbalance Strategy:** `Loss_WeightedCE_Uniform` (uniform shuffle + inverse class weights, no sampler) achieved the highest Fold-0 test accuracy at **`85.90%`** (`0.8981` F1, `63.25%` Specificity, `0.9384` AUC). - **Batch Feature-Consistency Regularizer (`λ_phys`):** Sweeping `λ_phys ∈ {0.0, 0.01, 0.05, 0.20}` kept high internal Val accuracy (`98.8%–99.1%`) while degrading external Test ROC-AUC sharply from **`0.9588` (`λ=0.0`) → `0.8514` (`λ=0.01`) → `0.7233` (`λ=0.05`)** and `0.8867` (`λ=0.20`), empirically validating why `λ_phys = 0.0` is used in all clean configurations. --- ## Visualizations | Figure | Description | |---|---| | [Confusion Matrices](figures/fig1_priority1_confusion_matrices.png) | Side-by-side held-out test confusion matrices (`N = 624`, fixed `t = 0.50`) for all 5 verified Aug-12 models. | | [ROC & Calibration](figures/fig2_roc_and_calibration.png) | Ranking ROC-AUC vs. top-label reliability calibration explaining why Student KD wins at `t = 0.50`. | | [Patient-Grouped CV](figures/fig3_priority3_patient_cv.png) | Per-fold accuracy/F1/AUC across all 5 patient-grouped folds + pooled `N = 5,232` OOF confusion matrix. | | [Clean 256-d Ablations](figures/fig4_priority4_ablations.png) | Complete 11-variant Fold-0 test accuracy & 95% CI comparison at fixed `t = 0.50`. | --- ## Repository Structure ```text BioHCL-SSSM/ ├── README.md # Overview, verified metrics, quick-start ├── TECHNICAL_REPORT.md # Full audit report, Old-vs-New comparison & disclosures D1–D7 ├── requirements.txt # Clean Python dependencies ├── src/ │ ├── models/biohcl_sssm.py # Single canonical BioHCLSSSM (`256-d`, `L=2` default) + MHSA/ResNet50 │ ├── data/dataset.py # Union-Find patient + MD5 grouping + StratifiedGroupKFold │ ├── losses/losses.py # FP32 CE, Weighted CE, Focal (γ=2), & documented consistency term │ ├── training/trainer.py # Shared AdamW + warmup-cosine loop, collapse guard & FP32 eval │ └── utils/metrics.py # Acc/Prec/Rec/Spec/F1/AUC/PR-AUC/Brier/ECE, 10k bootstrap, McNemar ├── scripts/ │ ├── smoke_check.py # Architecture, forward/backward, zero-leakage & zero-secret check │ ├── evaluate_single_checkpoint.py # Standalone FP32 checkpoint evaluator CLI │ ├── run_phase0_eval.py # Reproduce Priority 1 official test evaluation + McNemar tests │ ├── run_phase1_groupkfold.py # Reproduce Priority 3 5-fold patient-grouped CV │ ├── run_phase1_ablations.py # Reproduce Priority 4 11-variant 256-d ablation suite │ └── generate_figures.py # Regenerate all 4 300-DPI figures from CSV/NPZ outputs ├── results/ # Audited CSVs, JSON summaries, McNemar results & NPZ probabilities ├── figures/ # 300-DPI PNG figures └── checkpoints/ # 21 clean verified `.pt` state_dicts + checkpoints/README.md ``` --- ## Quick Start & Reproducibility ```bash pip install -r requirements.txt # 1. Verify package integrity, zero secrets, zero thop buffers, and patient/MD5 CV isolation python scripts/smoke_check.py # 2. Evaluate the verified Aug-12 Student BioHCL-SSSM checkpoint on official Kermany test (N=624) python scripts/evaluate_single_checkpoint.py \ --checkpoint checkpoints/aug12_verified/biohcl_sssm_student_256d.pt \ --data-dir /path/to/chest_xray # 3. Reproduce full Priority 1 table + exact McNemar test + Brier/ECE python scripts/run_phase0_eval.py --data-dir /path/to/chest_xray # 4. Reproduce 5-fold patient-grouped CV (official test/ untouched) python scripts/run_phase1_groupkfold.py --data-dir /path/to/chest_xray # 5. Reproduce the unified 11-variant 256-d ablation suite on Fold 0 python scripts/run_phase1_ablations.py --data-dir /path/to/chest_xray --epochs 30 --patience 8 ``` --- ## Mandatory Scientific Scope & Limitations - **Single-Dataset Provenance:** All experiments in this repository were executed strictly on the **Kermany Pediatric Chest X-Ray cohort** (`ages 1–5`, Guangzhou Women and Children's Medical Center). Results do not establish generalization to adult populations or other modalities (no Brain MRI, RSNA, or NIH runs were executed). - **Kermany Dataset Artifacts:** Official `test/PNEUMONIA/` restarts `person` numbering independently of `train/`; patient tokens are disambiguated by split prefix (`{split}_person_{id}`). One exact-byte duplicate pair exists inside official `test/NORMAL` (`NORMAL2-IM-0095-0001.jpeg == NORMAL2-IM-0096-0001.jpeg`) and is retained unmodified inside `N = 624` for benchmark comparability. - **Architecture & Regularizer Transparency:** `ResidualConnector` projection/norm layers (`132,608` params inside the `8,340,554` trainable total) exist inside `state_dict` for checkpoint compatibility while `BioHCLSSSM.forward()` reads `skip_step` directly. The auxiliary `features.roll(1)` L2 penalty is accurately documented as a **Batch Feature-Consistency Regularizer** (disabled at `λ_phys = 0.0`), not a biophysical PDE loss. - **Clinical Sensitivity vs. Specificity:** At fixed `t = 0.50`, all models prioritize Pneumonia Sensitivity (`≥ 90%` / `99.49%`) with moderate external Specificity (`44%–73.5%`). Clinical deployment would require threshold calibration on a dedicated held-out validation calibration subset.