Update README.md
Browse files
README.md
CHANGED
|
@@ -159,10 +159,11 @@ lumen boundary.
|
|
| 159 |
|
| 160 |
### Failure mode
|
| 161 |
|
| 162 |
-
One badly-fixed external tubule
|
| 163 |
-
|
| 164 |
-
|
| 165 |
-
|
|
|
|
| 166 |
|
| 167 |
### Validated scope
|
| 168 |
|
|
|
|
| 159 |
|
| 160 |
### Failure mode
|
| 161 |
|
| 162 |
+
One badly-fixed external tubule was grossly under-segmented: the lumen was missed
|
| 163 |
+
entirely and only ~⅓ of the tubule area was captured (tubule boundary displaced
|
| 164 |
+
−10 µm inward, a clear outlier). The model's **status output flagged it as CHECK**
|
| 165 |
+
(1 of 9 flagged across the 129 images), so the failure is surfaced for review rather
|
| 166 |
+
than passed off as a valid measurement.
|
| 167 |
|
| 168 |
### Validated scope
|
| 169 |
|