license: cc-by-nc-4.0
library_name: timm
pipeline_tag: image-classification
tags: [endomet-net, medical-imaging, endometriosis, laparoscopy, surgery, convnext, research-only]
datasets: [GLENDA]
---

# EndoMet-Net: endometriosis vs no-pathology classifier for laparoscopic frames (GLENDA v1.0)

**Research use only. This is not a medical device and must not be used for clinical decisions.**

Given a single laparoscopic video frame, the model estimates whether visible endometriosis is present.
It is an ensemble of three ConvNeXt-Tiny models (one per cross-validation fold), initialised from
`timm/convnext_tiny.fb_in22k_ft_in1k` (ImageNet-22k pretraining) and fine-tuned on GLENDA v1.0.

- **Author:** MARTIN MAATI MABERA
- **Classes:** `no_endometriosis`, `endometriosis`
- **Input:** RGB frame resized to 384x384, ImageNet normalisation
- **Output:** probability per class (mean of the 3 fold models, each averaged with a horizontal flip)

## Quick start
```bash
pip install timm safetensors torch torchvision pillow
python inference.py frame.jpg
```

## Training data
GLENDA v1.0 (Leibetseder et al., 2020): 5,049 frames used (302 lesion sequences
labelled from expert masks, 27 no-pathology sequences; at most 40
evenly spaced frames per sequence), from an estimated 156 surgeries.

## Evaluation protocol
- 3-fold cross-validation, stratified by class and **grouped by surgery**, so no surgery contributes frames to both
  training and held-out data within a fold.
- GLENDA does not provide patient identifiers. Surgeries were approximated as groups of videos with consecutive IDs,
  merged further when they shared an identical frame (perceptual hash) or a near-identical frame (cosine similarity of
  ImageNet-pretrained ConvNeXt-T embeddings > 0.95).
- Metrics are frame-level unless stated; sequence-level scores average predictions over each video sequence.

## Results (held-out surgeries, ConvNeXt-T, 3 folds)
| Metric (%) | Mean ± SD | Fold 0 | Fold 1 | Fold 2 |
|---|---|---|---|---|
| AUC | 96.1 ± 4.1 | 91.3 | 98.5 | 98.4 |
| Sensitivity | 93.5 ± 4.2 | 88.8 | 97.0 | 94.8 |
| Specificity | 89.0 ± 8.6 | 79.4 | 96.1 | 91.6 |
| Macro-F1 | 89.7 ± 6.3 | 82.4 | 94.2 | 92.3 |
| Balanced accuracy | 91.3 ± 6.4 | 84.1 | 96.5 | 93.2 |
| Accuracy | 92.5 ± 5.3 | 86.6 | 96.9 | 94.0 |
| Sequence-level macro-F1 | 84.8 ± 7.5 | 78.9 | 93.3 | 82.2 |

Each fold model is scored on its own held-out surgeries. The released ensemble averages the three fold models; its
performance on new patients is estimated by these cross-validation results and was not measured separately.

## Disclosures and limitations
- **Near-duplicate analysis.** After grouping, we measured each held-out frame's highest similarity to any training
  frame (fold 0): 0.0% of held-out frames had a training match above 0.95,
  0.4% above 0.93 and 9.2% above 0.90 (median nearest-neighbour similarity
  0.862). Visual inspection of the most similar pairs (about 0.94) suggested that a small number of
  held-out frames may still depict the same surgical scene as training frames under different video IDs. A sensitivity
  analysis with a stricter threshold (0.92) was not performed for this release, so the reported performance may be
  slightly optimistic.
- **Model selection.** The training epoch was chosen by early stopping on each fold's held-out data, which can also
  make the reported scores slightly optimistic.
- **Shortcut checks.** All frames share one resolution (640x360), and no-pathology video IDs fall within the range of
  lesion video IDs (no separate recording batch).
- **Shortcut probe and Grad-CAM:** not yet performed. We have not yet verified with saliency maps that predictions rely on lesion regions rather than other scene content.
- **Small healthy class.** No-pathology frames come from about 18 surgeries, so the
  specificity estimate rests on few patients.
- **Single source.** All data come from one dataset; performance on other hospitals, cameras or populations is unknown.
  No external validation was performed.
- **Frame labels.** Sequence frames inherit the label of the sequence's expert-annotated keyframe; a lesion may be
  partly hidden or out of view in some frames.

## License
CC BY-NC 4.0, following the GLENDA dataset license (non-commercial use only, attribution required).
Check the license of the initial weights (`timm/convnext_tiny.fb_in22k_ft_in1k`) on its model card before reuse.

## Citations
- A. Leibetseder, S. Kletz, K. Schoeffmann, S. Keckstein, J. Keckstein. *GLENDA: Gynecologic Laparoscopy Endometriosis
  Dataset.* MultiMedia Modeling (MMM) 2020.
- Z. Liu et al. *A ConvNet for the 2020s.* CVPR 2022.
- R. Wightman. *PyTorch Image Models (timm).* https://github.com/huggingface/pytorch-image-models