"""Runtime-lifecycle unit for long-lived health surfaces.
A health surface may run inside a long-lived, possibly daemon-thread-hosted
process — the web terminal's sidecar app or the stdio health MCP server.
:class:`HealthRuntimeLifecycle` owns the single
:class:`~osprey.health.runtime.HealthRuntime` for that process and the rules
that keep its control-system connector safe there:
* **Lazy, snapshot-driven construction.** The runtime is created from the first
refresh's ``control_system`` config snapshot — the CLI's own guard expression
``(expanded or {}).get("control_system", {}) or {}`` — via :meth:`reconcile`,
called once per refresh cycle.
* **Re-snapshot before first connect; restart-notice after.** While the runtime
has never constructed a connector (``ever_constructed`` is False), a changed
``control_system`` mapping simply replaces the runtime — race-free and with
zero Channel Access risk, so a broken-config first refresh cannot latch an
empty mapping. Once a connector *has* been constructed, a changed mapping is
never swapped in-process (an in-flight CA connector swap is a libca crash
class in a shared host process); instead it is surfaced explicitly as a
one-time warning log plus an informational result row on every subsequent
report until the process restarts.
* **Loop-affine, refresh-serialized teardown.** The connector must be
disconnected on the event loop that constructed it. Both the lifespan shutdown
path (:meth:`shutdown`) and the ``atexit`` hook first cancel and await any
in-flight refresh task, then run :meth:`HealthRuntime.shutdown` — whose
``closed`` flag prevents any post-teardown resurrection. The ``atexit`` hook
no-ops unless a connector was constructed, submits to the owning loop via
``run_coroutine_threadsafe``, and wraps its bounded wait so a wedged teardown
logs a single warning rather than dumping a traceback to stderr at exit.
The unit is deliberately free of FastAPI and cache/scheduler concerns: the app
factory drives loop binding and lifespan teardown, and the refresh engine calls
:meth:`reconcile` and reads :attr:`runtime`. The engine supplies its in-flight
refresh task through ``inflight_task_provider`` so teardown can serialize
against it.
"""
from __future__ import annotations
import asyncio
import atexit
import logging
from collections.abc import Callable
from typing import Any
from osprey.health.models import CheckResult, Status
from osprey.health.runtime import HealthRuntime
logger = logging.getLogger("osprey.health.lifecycle")
#: Default surface-neutral restart hint. Surfaces pass their own via
#: ``HealthRuntimeLifecycle(restart_hint=...)`` so the notice names the process
#: the operator (or agent) can actually restart.
DEFAULT_RESTART_HINT = "restart the health service"
def restart_notice_message(restart_hint: str = DEFAULT_RESTART_HINT) -> str:
"""Compose the message shown (log + result row) when ``control_system``
config changes after a connector has been constructed and cannot be swapped
in-process."""
return f"control_system config changed; {restart_hint} to apply"
#: The default-composed message, kept for callers/tests that don't customize the hint.
RESTART_NOTICE_MESSAGE = restart_notice_message()
#: Bounded wait for the ``atexit`` teardown to complete on the owning loop. Kept
#: as a module constant so a process exiting while the loop is wedged never hangs
#: longer than this; tests monkeypatch it to stay fast.
ATEXIT_SHUTDOWN_TIMEOUT_S = 5.0
# Type of the callable the engine supplies to expose its in-flight refresh task.
InflightTaskProvider = Callable[[], "asyncio.Task[Any] | None"]
def control_system_snapshot(expanded: dict[str, Any] | None) -> dict[str, Any]:
"""Return the ``control_system`` section from an expanded config mapping.
Mirrors the CLI guard expression ``(expanded or {}).get("control_system",
{}) or {}`` exactly: a missing config, a missing section, or an explicit
``control_system: null`` all normalize to an empty mapping.
"""
return (expanded or {}).get("control_system", {}) or {}
def _restart_notice_row(message: str) -> CheckResult:
"""Build the informational row surfaced after an unapplied config change."""
return CheckResult(
name="control_system",
category="configuration",
status=Status.WARNING,
message=message,
)
class HealthRuntimeLifecycle:
"""Owns the health sidecar's single connector runtime and its teardown.
Args:
inflight_task_provider: Optional callable returning the refresh engine's
current in-flight suite task (or ``None`` when idle). Teardown
cancels and awaits it before disconnecting the connector so the two
never race. May instead be supplied later via
:meth:`set_inflight_task_provider`.
restart_hint: Surface-specific phrase naming the process to restart when
a ``control_system`` change cannot be applied in-process (e.g.
``"restart the web terminal"``). Composed into the notice row and
warning log via :func:`restart_notice_message`.
"""
def __init__(
self,
inflight_task_provider: InflightTaskProvider | None = None,
*,
restart_hint: str = DEFAULT_RESTART_HINT,
) -> None:
self.restart_notice_message = restart_notice_message(restart_hint)
self._runtime: HealthRuntime | None = None
# The ``control_system`` mapping the current runtime was built from.
self._active_control_system: dict[str, Any] | None = None
# The mapping we last emitted a restart-notice *log* for (dedupes the
# warning while the result row still renders on every report).
self._noticed_control_system: dict[str, Any] | None = None
self._loop: asyncio.AbstractEventLoop | None = None
self._atexit_registered = False
self._inflight_task_provider = inflight_task_provider
@property
def runtime(self) -> HealthRuntime | None:
"""The current runtime, or ``None`` before the first :meth:`reconcile`."""
return self._runtime
@property
def atexit_registered(self) -> bool:
"""Whether the process-exit teardown hook is currently registered."""
return self._atexit_registered
def set_inflight_task_provider(self, provider: InflightTaskProvider | None) -> None:
"""Set (or clear) the callable exposing the engine's in-flight task."""
self._inflight_task_provider = provider
# -- snapshot / re-snapshot -------------------------------------------------
def reconcile(self, expanded: dict[str, Any] | None) -> list[CheckResult]:
"""Reconcile the runtime with the latest config snapshot.
Called once per refresh cycle with the just-loaded expanded config. On
the first call it constructs the runtime from the ``control_system``
snapshot. On later calls:
* an unchanged snapshot is a no-op;
* a changed snapshot while no connector was ever constructed silently
replaces the runtime with one built from the new snapshot;
* a changed snapshot after a connector was constructed logs a one-time
warning and returns the restart-notice row, leaving the live runtime
untouched.
Returns the extra result rows the engine should append to the report —
empty except for the post-construction restart-notice case, where the
single notice row is returned on every subsequent divergent refresh.
"""
snapshot = control_system_snapshot(expanded)
if self._runtime is None:
self._runtime = HealthRuntime(snapshot)
self._active_control_system = snapshot
return []
if snapshot == self._active_control_system:
# Back in sync with the live runtime (or never diverged): clear the
# log-dedupe latch so a future change warns again.
self._noticed_control_system = None
return []
if not self._runtime.ever_constructed:
# No Channel Access client was ever created — dropping the old
# runtime and re-snapshotting is race-free and CA-risk-free.
self._runtime = HealthRuntime(snapshot)
self._active_control_system = snapshot
self._noticed_control_system = None
return []
# A connector is live; the config changed. Never swap in-process — warn
# once and surface the notice row until the process restarts.
if snapshot != self._noticed_control_system:
logger.warning("HealthRuntime: %s", self.restart_notice_message)
self._noticed_control_system = snapshot
return [_restart_notice_row(self.restart_notice_message)]
# -- teardown ---------------------------------------------------------------
def bind_loop(self, loop: asyncio.AbstractEventLoop | None = None) -> None:
"""Capture the owning event loop (call from lifespan startup on the loop).
With no argument the currently running loop is captured; an explicit loop
may be passed (used by tests). The captured loop is the one the ``atexit``
hook submits teardown to, guaranteeing connector disconnect runs on the
thread that constructed it.
"""
self._loop = loop or asyncio.get_running_loop()
def register_atexit(self) -> None:
"""Register the process-exit teardown hook (idempotent)."""
if self._atexit_registered:
return
atexit.register(self._atexit_shutdown)
self._atexit_registered = True
def unregister_atexit(self) -> None:
"""Unregister the process-exit teardown hook (idempotent).
Called on clean lifespan shutdown so short-lived ``TestClient`` apps do
not stack hooks across the process lifetime.
"""
if not self._atexit_registered:
return
atexit.unregister(self._atexit_shutdown)
self._atexit_registered = False
async def shutdown(self) -> None:
"""Lifespan-shutdown teardown, run on the owning loop's thread.
Cancels and awaits any in-flight refresh task, disconnects the connector
exactly once (a never-constructed runtime is a no-op), then unregisters
the ``atexit`` hook. Idempotent and exception-safe: a runtime whose
``disconnect`` raises is swallowed by :meth:`HealthRuntime.shutdown`.
"""
await self._cancel_inflight()
if self._runtime is not None:
await self._runtime.shutdown()
self.unregister_atexit()
async def _cancel_inflight(self) -> None:
"""Cancel and await the engine's in-flight refresh task, if any.
Best-effort: a task that raises on cancellation (or otherwise) must not
prevent teardown from proceeding to the connector disconnect.
"""
if self._inflight_task_provider is None:
return
task = self._inflight_task_provider()
if task is None or task.done():
return
task.cancel()
try:
await task
except asyncio.CancelledError:
pass
except Exception:
logger.debug(
"HealthRuntime: in-flight refresh raised during teardown (ignored)",
exc_info=True,
)
def _atexit_shutdown(self) -> None:
"""Process-exit hook: disconnect the connector on the owning loop.
No-ops unless a connector was actually constructed (nothing to
disconnect otherwise, and no reason to touch the loop). Submits the
teardown coroutine to the owning loop via ``run_coroutine_threadsafe``
and waits at most :data:`ATEXIT_SHUTDOWN_TIMEOUT_S`. On timeout or any
error it logs a single warning and returns — never a stderr traceback at
interpreter exit.
"""
runtime = self._runtime
if runtime is None or not runtime.ever_constructed:
return
loop = self._loop
if loop is None or loop.is_closed():
return
try:
future = asyncio.run_coroutine_threadsafe(self._teardown_connector(), loop)
future.result(timeout=ATEXIT_SHUTDOWN_TIMEOUT_S)
except Exception:
# exc_info deliberately omitted: one clean line, no exit-time traceback.
logger.warning("HealthRuntime: connector teardown at exit did not complete cleanly")
async def _teardown_connector(self) -> None:
"""Cancel the in-flight refresh, then disconnect the connector once."""
await self._cancel_inflight()
if self._runtime is not None:
await self._runtime.shutdown()

Xet Storage Details