"""Health runtime — single owner of the control-system connector lifecycle.
`HealthRuntime` is an async context manager that lazily constructs at most one
control-system connector and at most one archiver connector, disconnecting each
exactly once on exit. It is the sole owner of both connectors' lifecycles for a
health-suite run: probes that need a control-system connection (e.g.
``channel_read``) acquire it via :meth:`HealthRuntime.get_connector`, and probes
that query the archiver (e.g. ``archiver_freshness``) acquire it via
:meth:`HealthRuntime.get_archiver`; each constructs its connector on first call
and caches it for the rest of the suite. A suite with no such probes never
triggers construction, so no Channel Access client is created — and no PV is
left for the garbage collector to finalize (a GC-finalized pyepics PV segfaults
libca).
The two accessors differ in how they source their config, reflecting the two
connectors' asymmetric roles. The control-system connector is the runtime's
raison d'être — its careful single-ownership exists precisely to keep the CA
client's lifecycle safe — so its config is fixed at construction. The archiver
connector is a secondary, HTTP-class resource (EPICS Archiver Appliance,
MongoDB, DOOCS — none Channel Access), so :meth:`get_archiver` takes its config
block per call, letting the probe honor an explicit per-run ``ctx.config`` over
the global singleton without threading archiver config through every
``HealthRuntime`` construction site.
The get/create/shutdown surface deliberately mirrors
:class:`osprey.mcp_server.control_system.server_context.ControlSystemContext`
and the construct-once/disconnect-once template in
``osprey.services.bluesky_bridge.app._lifespan`` so that P2 (FastAPI lifespan +
teardown hook) and P3 (per-process cache, ``server_context`` idiom) can reuse
this class without API changes.
"""
from __future__ import annotations
import asyncio
import logging
from types import TracebackType
from typing import TYPE_CHECKING, Any
from osprey.connectors.control_system.base import ControlSystemConnector
from osprey.health.models import CheckResult, Status
from osprey_connectors.types import baseline_target
if TYPE_CHECKING:
from osprey.connectors.archiver.base import ArchiverConnector
logger = logging.getLogger("osprey.health.runtime")
#: The subject the health runtime speaks under in the shared baseline-pinned
#: wording. Spelled once here so the row and any future health refusal cannot
#: drift apart.
HEALTH_SUBJECT = "HealthRuntime"
#: Name and category of the informational row. ``control_system`` is not a
#: health *category* anyone can run — no probe lives there — which is the point:
#: the row is a banner about the whole report, not a check that passed or failed.
BASELINE_ROW_NAME = "control_system.target"
BASELINE_ROW_CATEGORY = "control_system"
class HealthRuntime:
"""Async context manager owning at most one lazily-created connector.
The connector is constructed on the first :meth:`get_connector` call and
cached; subsequent calls return the same instance. On context exit (or an
explicit :meth:`shutdown`) the connector is disconnected exactly once, and
only if one was actually constructed. Teardown is best-effort: a
``disconnect()`` that raises is swallowed so a failing connector can never
mask the suite's own result.
Construction is serialized. Health checks run concurrently — probes within
a category are awaited together, and the categories themselves run under a
single ``gather`` — so several probes can reach an accessor while the
connector is still ``None``. Without a guard each of them would see the
empty slot, each would build a connector, and every assignment but the last
would orphan one: an unreferenced Channel Access client that :meth:`shutdown`
never disconnects, because it only ever knew about the instance that won the
race. Both accessors therefore take a single :class:`asyncio.Lock` and
re-test the cache inside it, so exactly one caller constructs and every
other waiter returns that same instance. The ``closed`` refusal stays
outside the lock: a runtime that has already torn its connectors down must
say so immediately rather than queue behind an in-flight construction.
Args:
control_system_config: The ``control_system`` config section passed
straight to
:meth:`ConnectorFactory.create_control_system_connector`.
"""
def __init__(self, control_system_config: dict[str, Any]) -> None:
self._config = control_system_config
self._connector: ControlSystemConnector | None = None
self._ever_constructed = False
self._archiver: ArchiverConnector | None = None
self._archiver_ever_constructed = False
self._closed = False
#: Guards lazy construction in both accessors (see the class docstring).
#: Held only across construction, never across teardown.
self._lock = asyncio.Lock()
@property
def ever_constructed(self) -> bool:
"""Whether a connector was ever successfully constructed.
Becomes ``True`` at the first successful :meth:`get_connector` and
stays ``True`` thereafter. Unlike ``_connector is None`` — which
:meth:`shutdown` also produces — this records construction *history*,
letting callers distinguish "never built a connector" from "built one
and then tore it down".
"""
return self._ever_constructed
@property
def archiver_ever_constructed(self) -> bool:
"""Whether an archiver connector was ever successfully constructed.
Tracked separately from :attr:`ever_constructed` (which records the
control-system connector's history), so the archiver's presence never
influences control-system-specific reconciliation such as the web
sidecar's config-change restart notice.
"""
return self._archiver_ever_constructed
@property
def closed(self) -> bool:
"""Whether :meth:`shutdown` has run (via explicit call or context exit).
Once ``True``, :meth:`get_connector` refuses rather than reconstructing.
"""
return self._closed
async def __aenter__(self) -> HealthRuntime:
return self
async def __aexit__(
self,
exc_type: type[BaseException] | None,
exc: BaseException | None,
tb: TracebackType | None,
) -> None:
await self.shutdown()
async def get_connector(self) -> ControlSystemConnector:
"""Return the cached connector, constructing it on first call.
The first call registers the built-in connector types (idempotent) and
creates the control-system connector from the configured section. Later
calls return the same cached instance. After :meth:`shutdown` the
runtime is closed and this refuses with :class:`RuntimeError` rather
than reconstructing a connector the suite already tore down.
Concurrent callers are serialized, so two probes that both find the slot
empty still produce one connector between them; the closed check runs
before the lock, so a closed runtime refuses at once.
"""
if self._closed:
raise RuntimeError(
"HealthRuntime is closed; get_connector() cannot reconstruct "
"a connector after shutdown()"
)
async with self._lock:
if self._connector is None:
from osprey.connectors.factory import (
ConnectorFactory,
register_builtin_connectors,
)
register_builtin_connectors() # idempotent; must run before create
# A health run is not a session and never switches: the target
# it probes is the one its own configured section describes.
connector = await ConnectorFactory.create_control_system_connector(
self._config, control_target=baseline_target(self._config)
)
if self._closed:
# shutdown() ran during construction: it found the slot
# empty and disconnected nothing, so this one is ours to
# close — installing it would orphan it.
await self._disconnect_one("connector", connector)
raise RuntimeError(
"HealthRuntime was closed while its connector was being constructed"
)
self._connector = connector
self._ever_constructed = True
logger.info(
"HealthRuntime: constructed control-system connector (%s)",
type(self._connector).__name__,
)
return self._connector
async def get_archiver(self, archiver_config: dict[str, Any]) -> ArchiverConnector:
"""Return the cached archiver connector, constructing it on first call.
The first call registers the built-in connector types (idempotent) and
creates the archiver connector from *archiver_config* — the ``archiver:``
config block (``type`` plus the per-type sub-block), which the caller
resolves with the correct precedence (an explicit per-run ``ctx.config``
over the global singleton). ``ConnectorFactory.create_archiver_connector``
connects on construction, so a first call that returns is proof the
archiver was reachable. Later calls return the same cached instance and
ignore *archiver_config* — a suite runs against one archiver.
After :meth:`shutdown` the runtime is closed and this refuses with
:class:`RuntimeError` rather than reconstructing a connector the suite
already tore down.
Construction is serialized on the same lock as :meth:`get_connector`, so
concurrent archiver probes build one connector between them rather than
one apiece.
Args:
archiver_config: The ``archiver`` config block passed straight to
:meth:`ConnectorFactory.create_archiver_connector`.
"""
if self._closed:
raise RuntimeError(
"HealthRuntime is closed; get_archiver() cannot reconstruct "
"an archiver connector after shutdown()"
)
async with self._lock:
if self._archiver is None:
from osprey.connectors.factory import (
ConnectorFactory,
register_builtin_connectors,
)
register_builtin_connectors() # idempotent; must run before create
archiver = await ConnectorFactory.create_archiver_connector(archiver_config)
if self._closed:
# Same window as get_connector: closed mid-construction.
await self._disconnect_one("archiver connector", archiver)
raise RuntimeError(
"HealthRuntime was closed while its archiver connector was being constructed"
)
self._archiver = archiver
self._archiver_ever_constructed = True
logger.info(
"HealthRuntime: constructed archiver connector (%s)",
type(self._archiver).__name__,
)
return self._archiver
@staticmethod
def baseline_pinned_row() -> CheckResult | None:
"""The informational row naming both targets, or ``None`` on the baseline.
The health suite reports on the deployment *as configured*: its
connectors are built from the config section fixed at construction, and
a control-target switch does not move them. That is
the never-swap ruling, and this row does not change it — it makes it
visible. While the deployment is switched away, a reader would otherwise take
an ``ok`` row about the baseline target as an ``ok`` row about the target
they are working on.
The sentence comes from
:func:`osprey.mcp_server.control_system.target_banner.baseline_pinned_line`,
the same helper the Phoebus tools render their label from, so the two
pinned holders cannot word the same fact two ways. ``None`` on the
baseline keeps an unswitched report byte-identical to what it was before
this row existed.
Emitted as :data:`~osprey.health.models.Status.SKIP`: it is not a check,
so it must not count as one that passed, and skip is the one status that
leaves :attr:`~osprey.health.models.CheckReport.exit_code` alone.
Returns:
The row while the deployment is switched, otherwise ``None``. Never
raises — a banner that failed to render must not fail a health run.
"""
try:
from osprey.mcp_server.control_system.target_banner import baseline_pinned_line
line = baseline_pinned_line(HEALTH_SUBJECT)
except Exception: # noqa: BLE001 - a label can never cost a health run
logger.debug("Could not resolve the baseline-pinned row (ignored)", exc_info=True)
return None
if line is None:
return None
return CheckResult(BASELINE_ROW_NAME, BASELINE_ROW_CATEGORY, Status.SKIP, line)
async def shutdown(self) -> None:
"""Disconnect both connectors exactly once, iff each was constructed.
A never-constructed runtime disconnects nothing but still marks the
runtime closed. Disconnect exceptions are swallowed (best-effort
teardown), and each cached instance is cleared so a repeated call
disconnects nothing.
"""
self._closed = True
await self._disconnect_one("connector", self._connector)
self._connector = None
await self._disconnect_one("archiver connector", self._archiver)
self._archiver = None
@staticmethod
async def _disconnect_one(
label: str,
connector: ControlSystemConnector | ArchiverConnector | None,
) -> None:
"""Disconnect one connector best-effort, swallowing any exception.
A ``None`` connector (never constructed, or already cleared) is a no-op;
a ``disconnect()`` that raises is logged at debug and swallowed so a
failing connector can never mask the suite's own result.
"""
if connector is None:
return
try:
await connector.disconnect()
except Exception:
logger.debug(
"HealthRuntime: error disconnecting %s (ignored)",
label,
exc_info=True,
)

Xet Storage Details