| """Health runtime — single owner of the control-system connector lifecycle. | |
| `HealthRuntime` is an async context manager that lazily constructs at most one | |
| control-system connector and at most one archiver connector, disconnecting each | |
| exactly once on exit. It is the sole owner of both connectors' lifecycles for a | |
| health-suite run: probes that need a control-system connection (e.g. | |
| ``channel_read``) acquire it via :meth:`HealthRuntime.get_connector`, and probes | |
| that query the archiver (e.g. ``archiver_freshness``) acquire it via | |
| :meth:`HealthRuntime.get_archiver`; each constructs its connector on first call | |
| and caches it for the rest of the suite. A suite with no such probes never | |
| triggers construction, so no Channel Access client is created — and no PV is | |
| left for the garbage collector to finalize (a GC-finalized pyepics PV segfaults | |
| libca). | |
| The two accessors differ in how they source their config, reflecting the two | |
| connectors' asymmetric roles. The control-system connector is the runtime's | |
| raison d'être — its careful single-ownership exists precisely to keep the CA | |
| client's lifecycle safe — so its config is fixed at construction. The archiver | |
| connector is a secondary, HTTP-class resource (EPICS Archiver Appliance, | |
| MongoDB, DOOCS — none Channel Access), so :meth:`get_archiver` takes its config | |
| block per call, letting the probe honor an explicit per-run ``ctx.config`` over | |
| the global singleton without threading archiver config through every | |
| ``HealthRuntime`` construction site. | |
| The get/create/shutdown surface deliberately mirrors | |
| :class:`osprey.mcp_server.control_system.server_context.ControlSystemContext` | |
| and the construct-once/disconnect-once template in | |
| ``osprey.services.bluesky_bridge.app._lifespan`` so that P2 (FastAPI lifespan + | |
| teardown hook) and P3 (per-process cache, ``server_context`` idiom) can reuse | |
| this class without API changes. | |
| """ | |
| from __future__ import annotations | |
| import asyncio | |
| import logging | |
| from types import TracebackType | |
| from typing import TYPE_CHECKING, Any | |
| from osprey.connectors.control_system.base import ControlSystemConnector | |
| from osprey.health.models import CheckResult, Status | |
| from osprey_connectors.types import baseline_target | |
| if TYPE_CHECKING: | |
| from osprey.connectors.archiver.base import ArchiverConnector | |
| logger = logging.getLogger("osprey.health.runtime") | |
| #: The subject the health runtime speaks under in the shared baseline-pinned | |
| #: wording. Spelled once here so the row and any future health refusal cannot | |
| #: drift apart. | |
| HEALTH_SUBJECT = "HealthRuntime" | |
| #: Name and category of the informational row. ``control_system`` is not a | |
| #: health *category* anyone can run — no probe lives there — which is the point: | |
| #: the row is a banner about the whole report, not a check that passed or failed. | |
| BASELINE_ROW_NAME = "control_system.target" | |
| BASELINE_ROW_CATEGORY = "control_system" | |
| class HealthRuntime: | |
| """Async context manager owning at most one lazily-created connector. | |
| The connector is constructed on the first :meth:`get_connector` call and | |
| cached; subsequent calls return the same instance. On context exit (or an | |
| explicit :meth:`shutdown`) the connector is disconnected exactly once, and | |
| only if one was actually constructed. Teardown is best-effort: a | |
| ``disconnect()`` that raises is swallowed so a failing connector can never | |
| mask the suite's own result. | |
| Construction is serialized. Health checks run concurrently — probes within | |
| a category are awaited together, and the categories themselves run under a | |
| single ``gather`` — so several probes can reach an accessor while the | |
| connector is still ``None``. Without a guard each of them would see the | |
| empty slot, each would build a connector, and every assignment but the last | |
| would orphan one: an unreferenced Channel Access client that :meth:`shutdown` | |
| never disconnects, because it only ever knew about the instance that won the | |
| race. Both accessors therefore take a single :class:`asyncio.Lock` and | |
| re-test the cache inside it, so exactly one caller constructs and every | |
| other waiter returns that same instance. The ``closed`` refusal stays | |
| outside the lock: a runtime that has already torn its connectors down must | |
| say so immediately rather than queue behind an in-flight construction. | |
| Args: | |
| control_system_config: The ``control_system`` config section passed | |
| straight to | |
| :meth:`ConnectorFactory.create_control_system_connector`. | |
| """ | |
| def __init__(self, control_system_config: dict[str, Any]) -> None: | |
| self._config = control_system_config | |
| self._connector: ControlSystemConnector | None = None | |
| self._ever_constructed = False | |
| self._archiver: ArchiverConnector | None = None | |
| self._archiver_ever_constructed = False | |
| self._closed = False | |
| #: Guards lazy construction in both accessors (see the class docstring). | |
| #: Held only across construction, never across teardown. | |
| self._lock = asyncio.Lock() | |
| def ever_constructed(self) -> bool: | |
| """Whether a connector was ever successfully constructed. | |
| Becomes ``True`` at the first successful :meth:`get_connector` and | |
| stays ``True`` thereafter. Unlike ``_connector is None`` — which | |
| :meth:`shutdown` also produces — this records construction *history*, | |
| letting callers distinguish "never built a connector" from "built one | |
| and then tore it down". | |
| """ | |
| return self._ever_constructed | |
| def archiver_ever_constructed(self) -> bool: | |
| """Whether an archiver connector was ever successfully constructed. | |
| Tracked separately from :attr:`ever_constructed` (which records the | |
| control-system connector's history), so the archiver's presence never | |
| influences control-system-specific reconciliation such as the web | |
| sidecar's config-change restart notice. | |
| """ | |
| return self._archiver_ever_constructed | |
| def closed(self) -> bool: | |
| """Whether :meth:`shutdown` has run (via explicit call or context exit). | |
| Once ``True``, :meth:`get_connector` refuses rather than reconstructing. | |
| """ | |
| return self._closed | |
| async def __aenter__(self) -> HealthRuntime: | |
| return self | |
| async def __aexit__( | |
| self, | |
| exc_type: type[BaseException] | None, | |
| exc: BaseException | None, | |
| tb: TracebackType | None, | |
| ) -> None: | |
| await self.shutdown() | |
| async def get_connector(self) -> ControlSystemConnector: | |
| """Return the cached connector, constructing it on first call. | |
| The first call registers the built-in connector types (idempotent) and | |
| creates the control-system connector from the configured section. Later | |
| calls return the same cached instance. After :meth:`shutdown` the | |
| runtime is closed and this refuses with :class:`RuntimeError` rather | |
| than reconstructing a connector the suite already tore down. | |
| Concurrent callers are serialized, so two probes that both find the slot | |
| empty still produce one connector between them; the closed check runs | |
| before the lock, so a closed runtime refuses at once. | |
| """ | |
| if self._closed: | |
| raise RuntimeError( | |
| "HealthRuntime is closed; get_connector() cannot reconstruct " | |
| "a connector after shutdown()" | |
| ) | |
| async with self._lock: | |
| if self._connector is None: | |
| from osprey.connectors.factory import ( | |
| ConnectorFactory, | |
| register_builtin_connectors, | |
| ) | |
| register_builtin_connectors() # idempotent; must run before create | |
| # A health run is not a session and never switches: the target | |
| # it probes is the one its own configured section describes. | |
| connector = await ConnectorFactory.create_control_system_connector( | |
| self._config, control_target=baseline_target(self._config) | |
| ) | |
| if self._closed: | |
| # shutdown() ran during construction: it found the slot | |
| # empty and disconnected nothing, so this one is ours to | |
| # close — installing it would orphan it. | |
| await self._disconnect_one("connector", connector) | |
| raise RuntimeError( | |
| "HealthRuntime was closed while its connector was being constructed" | |
| ) | |
| self._connector = connector | |
| self._ever_constructed = True | |
| logger.info( | |
| "HealthRuntime: constructed control-system connector (%s)", | |
| type(self._connector).__name__, | |
| ) | |
| return self._connector | |
| async def get_archiver(self, archiver_config: dict[str, Any]) -> ArchiverConnector: | |
| """Return the cached archiver connector, constructing it on first call. | |
| The first call registers the built-in connector types (idempotent) and | |
| creates the archiver connector from *archiver_config* — the ``archiver:`` | |
| config block (``type`` plus the per-type sub-block), which the caller | |
| resolves with the correct precedence (an explicit per-run ``ctx.config`` | |
| over the global singleton). ``ConnectorFactory.create_archiver_connector`` | |
| connects on construction, so a first call that returns is proof the | |
| archiver was reachable. Later calls return the same cached instance and | |
| ignore *archiver_config* — a suite runs against one archiver. | |
| After :meth:`shutdown` the runtime is closed and this refuses with | |
| :class:`RuntimeError` rather than reconstructing a connector the suite | |
| already tore down. | |
| Construction is serialized on the same lock as :meth:`get_connector`, so | |
| concurrent archiver probes build one connector between them rather than | |
| one apiece. | |
| Args: | |
| archiver_config: The ``archiver`` config block passed straight to | |
| :meth:`ConnectorFactory.create_archiver_connector`. | |
| """ | |
| if self._closed: | |
| raise RuntimeError( | |
| "HealthRuntime is closed; get_archiver() cannot reconstruct " | |
| "an archiver connector after shutdown()" | |
| ) | |
| async with self._lock: | |
| if self._archiver is None: | |
| from osprey.connectors.factory import ( | |
| ConnectorFactory, | |
| register_builtin_connectors, | |
| ) | |
| register_builtin_connectors() # idempotent; must run before create | |
| archiver = await ConnectorFactory.create_archiver_connector(archiver_config) | |
| if self._closed: | |
| # Same window as get_connector: closed mid-construction. | |
| await self._disconnect_one("archiver connector", archiver) | |
| raise RuntimeError( | |
| "HealthRuntime was closed while its archiver connector was being constructed" | |
| ) | |
| self._archiver = archiver | |
| self._archiver_ever_constructed = True | |
| logger.info( | |
| "HealthRuntime: constructed archiver connector (%s)", | |
| type(self._archiver).__name__, | |
| ) | |
| return self._archiver | |
| def baseline_pinned_row() -> CheckResult | None: | |
| """The informational row naming both targets, or ``None`` on the baseline. | |
| The health suite reports on the deployment *as configured*: its | |
| connectors are built from the config section fixed at construction, and | |
| a control-target switch does not move them. That is | |
| the never-swap ruling, and this row does not change it — it makes it | |
| visible. While the deployment is switched away, a reader would otherwise take | |
| an ``ok`` row about the baseline target as an ``ok`` row about the target | |
| they are working on. | |
| The sentence comes from | |
| :func:`osprey.mcp_server.control_system.target_banner.baseline_pinned_line`, | |
| the same helper the Phoebus tools render their label from, so the two | |
| pinned holders cannot word the same fact two ways. ``None`` on the | |
| baseline keeps an unswitched report byte-identical to what it was before | |
| this row existed. | |
| Emitted as :data:`~osprey.health.models.Status.SKIP`: it is not a check, | |
| so it must not count as one that passed, and skip is the one status that | |
| leaves :attr:`~osprey.health.models.CheckReport.exit_code` alone. | |
| Returns: | |
| The row while the deployment is switched, otherwise ``None``. Never | |
| raises — a banner that failed to render must not fail a health run. | |
| """ | |
| try: | |
| from osprey.mcp_server.control_system.target_banner import baseline_pinned_line | |
| line = baseline_pinned_line(HEALTH_SUBJECT) | |
| except Exception: # noqa: BLE001 - a label can never cost a health run | |
| logger.debug("Could not resolve the baseline-pinned row (ignored)", exc_info=True) | |
| return None | |
| if line is None: | |
| return None | |
| return CheckResult(BASELINE_ROW_NAME, BASELINE_ROW_CATEGORY, Status.SKIP, line) | |
| async def shutdown(self) -> None: | |
| """Disconnect both connectors exactly once, iff each was constructed. | |
| A never-constructed runtime disconnects nothing but still marks the | |
| runtime closed. Disconnect exceptions are swallowed (best-effort | |
| teardown), and each cached instance is cleared so a repeated call | |
| disconnects nothing. | |
| """ | |
| self._closed = True | |
| await self._disconnect_one("connector", self._connector) | |
| self._connector = None | |
| await self._disconnect_one("archiver connector", self._archiver) | |
| self._archiver = None | |
| async def _disconnect_one( | |
| label: str, | |
| connector: ControlSystemConnector | ArchiverConnector | None, | |
| ) -> None: | |
| """Disconnect one connector best-effort, swallowing any exception. | |
| A ``None`` connector (never constructed, or already cleared) is a no-op; | |
| a ``disconnect()`` that raises is logged at debug and swallowed so a | |
| failing connector can never mask the suite's own result. | |
| """ | |
| if connector is None: | |
| return | |
| try: | |
| await connector.disconnect() | |
| except Exception: | |
| logger.debug( | |
| "HealthRuntime: error disconnecting %s (ignored)", | |
| label, | |
| exc_info=True, | |
| ) | |
Xet Storage Details