NaturalKnight's picture
Release VisualArtifactSpec 1.0 dataset
077605d
Raw History Blame Contribute Delete
10.7 kB
{
"id": "animations-videos-062",
"source": "vas",
"artifact_type": "dynamic_media",
"category": "animations-videos",
"acceptance_groups": {
"G01": [
"IF01"
],
"G02": [
"IF02",
"IF03",
"IF04",
"IF05",
"IF31"
],
"G03": [
"IF06",
"IF07",
"IF08",
"IF09"
],
"G04": [
"IF10",
"IF11",
"IF12",
"IF13"
],
"G05": [
"IF14",
"IF16",
"IF17",
"IF18",
"IF19"
],
"G06": [
"IF15",
"IF22",
"IF23"
],
"G07": [
"IF20"
],
"G08": [
"IF21",
"IF52",
"IF53"
],
"G09": [
"IF24",
"IF25",
"IF26",
"IF27",
"IF28",
"IF29",
"IF32",
"IF33",
"IF34",
"IF35",
"IF36",
"IF37"
],
"G10": [
"IF30",
"IF42",
"IF43",
"IF44",
"IF45",
"IF46"
],
"G11": [
"IF38",
"IF39",
"IF40",
"IF41",
"IF47",
"IF49",
"IF51"
],
"G12": [
"IF48",
"IF50"
],
"G13": [
"IF54"
]
},
"provenance": {
"source": "artifactspec",
"original_id": "P62",
"legacy_task_id": "artifactspec-P62"
},
"acceptance_objectives": {
"G01": {
"title": "Complete openable artifact handoff and source dependencies",
"dimension": "CP",
"scope": [
"Requirement: the deliverable file artifact/pumped-storage.mp4 exists."
],
"objective_key": "constraint:delivery"
},
"G02": {
"title": "Required artifact format, extent and duration",
"dimension": "CP",
"scope": [
"Requirement: the video resolution is 1280 × 720.",
"Requirement: the video codec is H.264.",
"Requirement: the video frame rate is 24 fps.",
"Requirement: the video duration is 24 seconds, with a tolerance of one frame.",
"Requirement: the first 12 seconds are the pumping/storage phase, and the final 12 seconds are the generation phase."
],
"objective_key": "constraint:format"
},
"G03": {
"title": "Required faithful previews and companion exports",
"dimension": "CP",
"scope": [
"Requirement: the checkpoint file artifact/checkpoints/04s.png exists.",
"Requirement: the checkpoint file artifact/checkpoints/10s.png exists.",
"Requirement: the checkpoint file artifact/checkpoints/16s.png exists.",
"Requirement: the checkpoint file artifact/checkpoints/22s.png exists."
],
"objective_key": "constraint:preview"
},
"G04": {
"title": "Deliver artifact/pumped-storage.mp4, 1280 × 720, H.264, 24 fps, duration 24 seconds (tolerance one frame). Include artifact/checkpoints/04s.png, 10s.png, 16s.png and 22s.png extracted from your final video, plus artifact/sources.md describing sources, the phase timing and how captures were obtained. No audio is required.",
"dimension": "CP",
"scope": [
"Requirement: 04s.png is a frame extracted from the final video at 4 seconds.",
"Requirement: 10s.png is a frame extracted from the final video at 10 seconds.",
"Requirement: 16s.png is a frame extracted from the final video at 16 seconds.",
"Requirement: 22s.png is a frame extracted from the final video at 22 seconds."
],
"objective_key": "requirement:prompt.md:4"
},
"G05": {
"title": "Complete reproducibility and delivery documentation",
"dimension": "CP",
"scope": [
"Requirement: the delivery documentation file artifact/sources.md exists.",
"Requirement: sources.md describes the sources used.",
"Requirement: sources.md describes the phase timing.",
"Requirement: sources.md describes how the captures were obtained.",
"Requirement: sources.md distinguishes source facts from the task's illustrative 24-second timing."
],
"objective_key": "constraint:notes"
},
"G06": {
"title": "Create a new 24-second English teaching animation for secondary-school students explaining pumped-storage hydropower. Use the local DOE explanation and official animation as references. Produce a newly drawn explanatory diagram with labels and staged causal explanation, rather than simply shortening or re-encoding the official movie.",
"dimension": "CP",
"scope": [
"Requirement: the animation production uses the local DOE explanation and the official animation as reference sources.",
"Requirement: the final animation is a newly drawn explanatory diagram, not a simple shortening or re-encoding of the official movie.",
"Requirement: the explanatory diagram includes labels."
],
"objective_key": "requirement:prompt.md:2"
},
"G07": {
"title": "Required artifact language",
"dimension": "CP",
"scope": [
"Requirement: on-screen text and narration use English."
],
"objective_key": "constraint:language"
},
"G08": {
"title": "Use concise English and gradually introduce the cause-and-effect relationships. At normal playback, leave enough time to read the explanations. Keep inputs read-only and place intermediates in scratch/. Sources.md must distinguish source facts from the task's illustrative 24-second timing. All required materials are local.",
"dimension": "CP",
"scope": [
"Requirement: the English explanatory text is concise, using short sentences or phrases rather than long paragraphs.",
"Requirement: causal relationships are introduced gradually, rather than all presented at once.",
"Requirement: each explanation has enough time to be read at normal playback speed."
],
"objective_key": "requirement:prompt.md:12"
},
"G09": {
"title": "Show a fixed arrangement with an upper reservoir, lower reservoir, connecting pipe, reversible pump/turbine and motor/generator, and a grid connection. Use the first 12 seconds for pumping/storage and the final 12 seconds for generation. Explain that pumping consumes electricity to move water uphill; generation lets water descend through the turbine to drive the generator and supply electricity. Animate both water flow and electricity flow, with a clear legend distinguishing them, and show the upper reservoir's stored-water level increasing then decreasing. Treat the diagram as qualitative, not to scale, without invented power, efficiency or reservoir-volume figures.",
"dimension": "CP",
"scope": [
"Requirement: the visuals include an upper reservoir.",
"Requirement: the visuals include a lower reservoir.",
"Requirement: the visuals include a connecting pipe.",
"Requirement: the visuals include a reversible pump/turbine.",
"Requirement: the visuals include a motor/generator.",
"Requirement: the visuals include a grid connection.",
"Requirement: explain that pumping consumes electricity and moves water upward.",
"Requirement: explain that during generation water descends through the turbine to drive the generator and supply electricity.",
"Requirement: water flow is presented as animated.",
"Requirement: electricity flow is presented as animated.",
"Requirement: there is a clear legend distinguishing water flow from electricity flow.",
"Requirement: the stored-water level of the upper reservoir first rises and then falls."
],
"objective_key": "requirement:prompt.md:6"
},
"G10": {
"title": "At 4 and 10 seconds the pumping state must be clear; at 16 and 22 seconds the generating state must be clear. Component locations should remain stable so viewers can compare states. Labels, flow direction and water-level changes must agree. The two modes are sequential, not a claim that the plant pumps and generates through the same unit simultaneously.",
"dimension": "CP",
"scope": [
"Requirement: component locations remain stable so the two states can be compared.",
"Requirement: the pumping state is clearly legible at 4 seconds.",
"Requirement: the pumping state is clearly legible at 10 seconds.",
"Requirement: the generating state is clearly legible at 16 seconds.",
"Requirement: the generating state is clearly legible at 22 seconds.",
"Requirement: labels, flow direction, and water-level changes are consistent with one another."
],
"objective_key": "requirement:prompt.md:8"
},
"G11": {
"title": "Evidence-bounded claims and truthful scenario identity",
"dimension": "CP",
"scope": [
"Requirement: the explanatory diagram remains qualitative and not to scale, and does not imply precise real-world dimensions or quantitative system performance.",
"Requirement: no invented power figures appear.",
"Requirement: no invented efficiency figures appear.",
"Requirement: no invented reservoir-volume figures appear.",
"Requirement: the two modes are sequential, not implying that the same unit pumps and generates simultaneously.",
"Requirement: do not imply a self-powered cycle.",
"Requirement: do not claim an exact energy balance."
],
"objective_key": "constraint:evidence-boundary"
},
"G12": {
"title": "The official animation illustrates one solar-powered daytime pumping / nighttime generation scenario. Do not generalize this into a rule that pumping always happens in daylight or generation only at night. Do not suggest a self-powered cycle: electricity is an input during pumping. Explain that the same water can be reused between the reservoirs. Do not claim an exact energy balance from this conceptual source.",
"dimension": "CP",
"scope": [
"Requirement: do not limit pumping to daytime or generation to nighttime.",
"Requirement: explain that the same water can be reused between the two reservoirs."
],
"objective_key": "requirement:prompt.md:10"
},
"G13": {
"title": "Unmodified original inputs and isolated working state",
"dimension": "CP",
"scope": [
"Requirement: input/reference files remain read-only and unmodified. [v7 verifiable boundary: check that the final inputs match the frozen snapshot file by file; it is not required to prove that no writing ever occurred during production. At public runtime, inputs are guaranteed by read-only mounts.]."
],
"objective_key": "constraint:input-integrity"
}
},
"grouping_revision": "cp-fn-objectives-v2-20261114"
}