AlejandroGZ commited on
Commit
2da9481
·
verified ·
1 Parent(s): b4d85c8

Upload README.md

Browse files
Files changed (1) hide show
  1. README.md +398 -264
README.md CHANGED
@@ -1,447 +1,581 @@
1
  ---
 
2
  tags:
3
- - synthetic-data
4
- - vibration
5
- - condition-monitoring
6
- - predictive-maintenance
7
- - anomaly-detection
8
- - industrial
9
- - rotating-machinery
10
- - time-series
11
- - anndata
12
- - vibframe
13
- - vibsynth
14
- pretty_name: VibSynth Motor-Pump Fleet 180d
15
  size_categories:
16
- - 100K<n<1M
17
  ---
18
- # VibSynth Motor-Pump Fleet 180d
19
 
20
- > **Status: dataset files are not published yet.**
21
- > This repository is being prepared as the public dataset card for the final **AnnData (`.h5ad`)** release. The data will be uploaded once the VibFrame → AnnData conversion and validation pipeline is complete.
22
 
23
- **VibSynth Motor-Pump Fleet 180d** is a synthetic condition-monitoring dataset representing **180 days of operation of a fleet of 12 equivalent variable-speed motor–centrifugal-pump units**.
 
24
 
25
- The scenario is designed for research on **unsupervised anomaly detection, condition monitoring, operating-regime modelling, progressive fault detection and machine-to-machine generalisation**.
26
 
27
- All measurements are **simulated**. No signal in this dataset comes from a real industrial plant or from a real monitored machine. The vibration data were generated with **VibSynth, a synthetic vibration generation tool developed by TWave**.
28
 
29
- The aim is not to present synthetic data as field measurements, but to provide a controlled industrially plausible benchmark in which the complete physical scenario and ground truth are known while the learning problem remains non-trivial.
30
 
31
- ---
32
-
33
- ## Why this dataset exists
34
-
35
- Industrial vibration datasets suitable for machine learning often suffer from one or more of the following limitations:
36
-
37
- - very few machines;
38
- - a single fixed operating condition;
39
- - abrupt, artificially injected faults;
40
- - insufficient healthy history;
41
- - little or no information about transitions between regimes;
42
- - a lack of machine-to-machine variability;
43
- - no distinction between an unknown operating condition and an actual mechanical degradation;
44
- - incomplete ground truth.
45
-
46
- This dataset was built specifically to create a more demanding controlled scenario.
47
-
48
- The fleet shares the same mechanical architecture, but individual units are not numerical clones. Machines operate under several partially shared process regimes, move naturally between them, and may develop one or more progressive faults at different moments in time.
49
-
50
- The first part of every machine's history is guaranteed to be healthy, allowing models to learn normality before faults appear.
51
 
52
  ---
53
 
54
  ## Industrial scenario
55
 
56
- The simulated installation represents a process plant containing **12 motor–pump assemblies**, identified as `M01` to `M12`.
57
 
58
- Each unit consists conceptually of:
59
 
60
  ```text
61
- Variable-frequency drive
62
  │
63
  Electric motor
64
  │
65
- Coupling
66
  │
67
  Centrifugal pump
68
  │
69
  Process line
70
  ```
71
 
72
- The twelve units belong to the same equipment family and use the same mechanical structure and sensing arrangement.
73
-
74
- Each pump is monitored on the pump drive-end bearing location using three vibration directions:
75
 
76
  - `pump_DE_H` — radial horizontal;
77
  - `pump_DE_V` — radial vertical;
78
  - `pump_DE_A` — axial.
79
 
80
- Small reproducible unit-to-unit tolerances are applied so that each machine has its own healthy vibration signature while remaining representative of the same fleet.
 
 
81
 
82
  ---
83
 
84
- ## Why the machines do not all use the same operating modes
 
 
 
 
 
 
85
 
86
- The pumps are mechanically equivalent, but they are assigned to **different process services inside the same installation**.
87
 
88
- This is intentional.
 
89
 
90
- A real plant may purchase the same pump package for several lines while using those units under different hydraulic requirements. For example, one line may routinely need short high-flow periods, another may regulate flow by throttling, and another may periodically recirculate product or coolant.
91
 
92
- For this reason, all machines share the two fundamental operating conditions, while additional modes occur only in the subset of units whose process duty requires them.
 
 
 
 
 
 
93
 
94
- ### Operating regimes
95
 
96
- | ID | Name | Base speed | Base load | Physical interpretation |
97
- |---|---|---:|---:|---|
98
- | `R1` | ECO | 1,000 rpm | 0.375 | Low process demand and reduced-speed operation |
99
- | `R2` | NOMINAL | 1,450 rpm | 0.675 | Standard production duty |
100
- | `R3` | PEAK | 1,700 rpm | 0.900 | Temporary high-flow / high-demand operation |
101
- | `R4` | THROTTLED | 1,450 rpm | 0.800 | Flow regulation with partially restricted discharge |
102
- | `R5` | RECIRCULATION | 1,225 rpm | 0.300 | Recirculation, flushing or process stabilisation |
103
 
104
- An important part of the scenario is that **operating regime is not reducible to rotational speed alone**.
105
 
106
- `R2` and `R4`, for example, use the same nominal speed but represent different hydraulic conditions and loads. A model must therefore deal with several forms of normal behaviour rather than simply map RPM to health.
107
 
108
- ### Regimes available to each unit
 
 
 
 
 
 
109
 
110
- | Machine | Normal regimes |
111
- |---|---|
112
- | `M01` | R1, R2, R3 |
113
- | `M02` | R1, R2, R3 |
114
- | `M03` | R1, R2, R3, R4 |
115
- | `M04` | R1, R2, R3 |
116
- | `M05` | R1, R2, R4 |
117
- | `M06` | R1, R2, R4 |
118
- | `M07` | R1, R2, R4, R5 |
119
- | `M08` | R1, R2, R4 |
120
- | `M09` | R1, R2, R3, R5 |
121
- | `M10` | R1, R2, R3, R5 |
122
- | `M11` | R1, R2, R5 |
123
- | `M12` | R1, R2, R5 |
124
 
125
- The operating history is stateful. Normal dwell periods last approximately **1–12 hours**, and machines do not change state in lockstep.
126
 
127
  ---
128
 
129
- ## Transitions are part of normality
 
 
130
 
131
- Real machinery does not jump instantaneously from one process condition to another.
 
 
 
 
 
 
 
 
 
 
132
 
133
- The dataset therefore contains explicit transitions between regimes. During a transition, rotational speed, load and the corresponding vibration response evolve continuously until the target state is reached.
134
 
135
- These periods are considered **legitimate normal operation**, not faults.
136
 
137
- This distinction is useful for anomaly-detection research because a detector should ideally avoid raising alarms merely because a healthy machine is accelerating, decelerating or changing process duty.
138
 
139
  ---
140
 
141
- ## Timeline
142
 
143
- The scenario starts at:
144
 
145
- **2026-01-01 00:00:00 UTC**
146
 
147
- and spans **180 days**.
148
 
149
- The history is divided conceptually into three temporal regions:
 
150
 
151
- | Period | Approx. days | Content | Intended use |
152
- |---|---:|---|---|
153
- | Calibration | 0–30 | Healthy operation only | Learn normal behaviour |
154
- | Normal holdout | 31–45 | Healthy unseen operation | Evaluate false positives |
155
- | Future stream | 46–180 | Healthy operation, OOD events and progressive faults | Online / temporal evaluation |
156
 
157
- No mechanical fault begins before **day 60**.
158
 
159
- The splits are temporal by design. Random row-wise train/test splitting is discouraged because it would leak information between neighbouring samples from the same evolving machine.
 
160
 
161
- ---
162
 
163
- ## Measurements
164
 
165
- ### Spectra
166
 
167
- A spectral snapshot is generated every **20 minutes**.
168
 
169
- For every machine and timestamp, the dataset contains measurements for the three sensor directions and two processing modes:
170
 
171
- - `VEL_1K` — velocity spectrum from 0 to 1,000 Hz;
172
- - `ACC_10K` — acceleration spectrum from 0 to 10,000 Hz.
173
 
174
- Each spectrum contains **1,601 frequency bins**.
 
 
 
 
 
175
 
176
- This results in:
177
 
178
- - 12,960 spectral snapshots per machine;
179
- - 155,520 fleet-level snapshot timestamps;
180
- - 6 spectra per snapshot;
181
- - **933,120 spectral rows** in the source VibFrame fixture.
182
 
183
- ### Waveforms
184
 
185
- A 1-second triaxial acceleration waveform is generated every **6 hours**.
186
 
187
- Each waveform channel contains:
 
 
 
 
 
 
188
 
189
- - sample rate: **51,200 Hz**;
190
- - samples: **51,200**;
191
- - duration: **1 second**.
192
 
193
- Across the complete fleet, the source fixture contains **25,920 waveform rows**.
194
 
195
- Waveforms and spectra generated at the same timestamp describe the same simulated machine condition, but they are not intended to be an exact FFT pair sample-by-sample.
 
 
196
 
197
  ---
198
 
199
- ## Progressive mechanical faults
200
 
201
- Faults are not introduced as abrupt binary changes.
202
 
203
- Each degradation begins at a machine-specific onset time and then grows in severity according to a fault-dependent curve. The underlying health deterioration persists across operating-mode changes.
204
 
205
- A machine can therefore be mildly degraded in one regime and show a much clearer vibration response in another.
206
 
207
- ### Fault plan
208
 
209
- | Machine | Fault 1 | Onset day | Fault 2 | Onset day |
210
- |---|---|---:|---|---:|
211
- | `M01` | Imbalance | 70 | — | — |
212
- | `M02` | Healthy | — | — | — |
213
- | `M03` | Angular misalignment | 83 | — | — |
214
- | `M04` | Bearing outer-race fault | 96 | — | — |
215
- | `M05` | Imbalance | 65 | Bearing outer-race fault | 105 |
216
- | `M06` | Mechanical looseness | 110 | — | — |
217
- | `M07` | Healthy | — | — | — |
218
- | `M08` | Angular misalignment | 90 | Mechanical looseness | 125 |
219
- | `M09` | Bearing inner-race fault | 125 | — | — |
220
- | `M10` | Bearing inner-race fault | 80 | Resonance | 120 |
221
- | `M11` | Healthy | — | — | — |
222
- | `M12` | Resonance | 75 | — | — |
223
 
224
- Three machines — `M02`, `M07` and `M11` — remain mechanically healthy throughout the complete 180-day period.
225
 
226
- The maximum simulated severity is **0.95**.
227
 
228
- Different fault families use different progression shapes, including linear, quadratic, accelerated bearing-type and intermittent-growth profiles.
229
 
230
- When two faults coexist, their mechanisms and severities remain separately represented in the evaluation ground truth.
231
 
232
- ---
233
 
234
- ## Operational OOD events
235
 
236
- Not every unusual operating condition is a mechanical fault.
237
 
238
- To test this distinction, the scenario contains three **out-of-distribution operating events** on machines that remain mechanically healthy:
239
 
240
- | Machine | Days | Approx. RPM | Load | Interpretation |
241
- |---|---|---:|---:|---|
242
- | `M02` | 100–103 | 1,800 | 0.35 | Unusual high-speed / low-load duty |
243
- | `M07` | 150–152 | 1,100 | 0.92 | Unusual low-speed / high-load duty |
244
- | `M11` | 118–120 | 1,580 | 0.25 | Unseen speed/load combination |
245
 
246
- These episodes intentionally test whether an anomaly detector can distinguish **novel operation** from **mechanical degradation**.
247
 
248
  ---
249
 
250
- ## Dataset scale
251
 
252
- The validated source VibFrame fixture contains:
253
 
254
- | Item | Count |
255
- |---|---:|
256
- | Machines | 12 |
257
- | Duration | 180 days |
258
- | Fleet spectral snapshots | 155,520 |
259
- | Spectral rows | 933,120 |
260
- | Waveform rows | 25,920 |
261
- | Evaluation truth rows | 155,520 |
262
- | Spectral bins per row | 1,601 |
263
- | Samples per waveform row | 51,200 |
264
- | Source fixture size | ~11.86 GB decimal / ~11.05 GiB |
 
 
 
265
 
266
- The Hugging Face release will be distributed after conversion to **AnnData**.
267
 
268
  ---
269
 
270
- ## Planned AnnData release
271
 
272
- The public artifact is intended to be an **AnnData (`.h5ad`) representation derived from the validated VibFrame source dataset**.
273
 
274
- The conversion pipeline is designed so that raw measurements and derived machine-learning features remain conceptually separate.
275
 
276
- The final layout will be documented together with the release. The intended organisation is:
277
 
278
- - `obs` — snapshot-level metadata;
279
- - `obsm` — raw or structured high-dimensional measurements such as spectra and waveforms;
280
- - `X` — derived feature matrix when features have been materialised;
281
- - `var` — feature definitions;
282
- - `uns` — dataset, machine and processing metadata.
283
-
284
- The exact schema will be frozen only after the VibFrame → AnnData converter has completed validation.
285
 
286
- **Until then, no `.h5ad` file in this repository should be considered final.**
287
 
288
  ---
289
 
290
- ## Ground truth and label leakage
291
 
292
- The source dataset contains detailed evaluation truth, including:
 
 
 
 
293
 
294
  - machine identity;
 
295
  - operating regime;
296
- - transition state;
297
- - true rotational speed;
298
- - true load;
299
- - health state;
300
- - active fault types;
301
- - fault onset timestamps;
302
- - continuous fault severities;
303
- - OOD operating events;
 
 
 
 
 
304
  - reproducibility seed.
305
 
306
- This information exists because the scenario is simulated.
 
 
 
 
307
 
308
- It must not automatically be treated as model input.
309
 
310
- For unsupervised anomaly-detection experiments, fields such as `health_state`, `fault_*`, `ood_operational` and the evaluation split should remain isolated from the training features.
 
 
 
 
311
 
312
- The ground truth is intended primarily for **evaluation, interpretability and reproducibility**.
313
 
314
  ---
315
 
316
- ## Reproducibility
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
317
 
318
- The scenario uses master seed:
 
 
319
 
320
  ```text
321
- 20260910
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
322
  ```
323
 
324
- Sub-seeds are derived deterministically for machine identity, operating timeline, spectra, waveforms and individual snapshots.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
325
 
326
- The dataset is therefore intended to provide a reproducible controlled benchmark rather than an opaque collection of generated samples.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
327
 
328
  ---
329
 
330
  ## Suggested research uses
331
 
332
- The dataset is particularly suitable for:
333
 
334
- - unsupervised and semi-supervised anomaly detection;
 
335
  - one-class learning;
336
- - fleet-level representation learning;
337
- - machine-to-machine transfer;
338
- - operating-regime-aware anomaly detection;
339
- - progressive fault / early-warning detection;
340
- - multi-fault behaviour;
341
- - novelty vs. mechanical-fault discrimination;
342
- - vibration feature engineering;
 
 
 
343
  - spectral representation learning;
344
- - multivariate H/V/A modelling;
345
- - temporal validation protocols;
346
- - explainable condition monitoring.
347
-
348
- It can also be used to compare classical vibration features against learned representations.
349
 
350
  ---
351
 
352
  ## Important limitations
353
 
354
- This dataset should not be interpreted as a replacement for field data.
355
 
356
- In particular:
357
-
358
- 1. **All signals are synthetic.**
359
  2. The plant and its operating history are fictitious.
360
- 3. VibSynth approximates mechanical and vibrational behaviour; it does not reproduce every structural, hydraulic, electrical or environmental non-linearity found in a real installation.
361
- 4. Coincident spectra and waveforms share the same simulated condition but are not the same exact signal realisation.
362
- 5. No keyphasor or tachometer pulse train is available.
363
- 6. Stored spectra contain magnitude only; absolute shaft-referenced phase cannot be recovered.
364
- 7. Waveforms are available every 6 hours rather than at every spectral snapshot.
365
- 8. Fault evolution is intentionally controlled and therefore cleaner than many real industrial degradation histories.
366
- 9. Results obtained on this dataset should ideally be validated later against independent real-world data.
367
 
368
  ---
369
 
370
- ## Data provenance
371
 
372
- The source fixture was generated using **VibSynth**, TWave's synthetic vibration generation tooling, and stored using the **VibFrame 0.2.0** data contract before conversion to AnnData.
373
 
374
- The source fixture passed its contractual validation with:
375
 
376
- - **0 errors**;
377
- - 12 non-blocking warnings related to the open `CentrifugalPump` node type;
378
- - 8 informational notes.
 
 
379
 
380
- The warnings do not affect the raw measurement schemas.
381
 
382
  ---
383
 
384
- ## Repository status
 
 
 
 
385
 
386
- ### Current
 
 
 
 
 
 
 
 
387
 
388
  - [x] Industrial scenario defined
389
- - [x] 180-day VibSynth simulation generated
390
- - [x] VibFrame source fixture validated
391
- - [x] Ground truth validated
392
- - [x] Dataset card prepared
393
- - [ ] VibFrame → AnnData conversion finalised
394
- - [ ] Final `.h5ad` validated
395
- - [ ] Dataset files uploaded to Hugging Face
396
- - [ ] Loading / usage examples added
397
- - [ ] Versioned first public release
398
-
399
- The repository may therefore be visible before the actual dataset files become available.
 
 
400
 
401
  ---
402
 
403
  ## Citation
404
 
405
- A formal citation will be added before the first public release.
406
 
407
- For now, if you refer to the dataset in preliminary work, please cite the Hugging Face repository and clearly describe it as a **synthetic VibSynth-generated dataset**.
408
 
409
  ```bibtex
410
- @dataset{vibsynth_motor_pump_fleet_180d,
411
- title = {VibSynth Motor-Pump Fleet 180d},
412
- author = {Gonzalez Zapico, Alejandro},
413
- year = {2026},
414
- publisher = {Hugging Face},
415
- note = {Synthetic industrial vibration dataset generated with VibSynth by TWave}
416
  }
417
  ```
418
 
419
  ---
420
 
421
- ## Acknowledgements
422
-
423
- This dataset was created in the context of work involving **TWave** and the **University of Oviedo**.
424
-
425
- Vibration data were simulated with **VibSynth**.
426
-
427
- ---
428
-
429
  ## License
430
 
431
  **To be defined before the first public release.**
432
 
433
- No reuse rights should be inferred from this placeholder. A concrete dataset license will be selected and added to the Hugging Face metadata before publication.
434
 
435
  ---
436
 
437
- ## Contact and feedback
438
 
439
- Issues, questions and reproducibility reports are welcome through the Hugging Face repository discussions once the dataset is released.
440
 
441
- When reporting results, please indicate:
442
 
443
- - whether raw spectra, waveforms or derived features were used;
444
- - whether rotational speed or regime information was included as an input;
445
  - which temporal split was used;
446
- - whether results are per-machine or fleet-level;
447
- - whether OOD operating periods were treated separately from mechanical faults.
 
 
 
 
 
 
1
  ---
2
+ pretty_name: "DRMHB — Dynamic Rotating Machinery Health Benchmark"
3
  tags:
4
+ - synthetic-data
5
+ - vibration
6
+ - condition-monitoring
7
+ - predictive-maintenance
8
+ - anomaly-detection
9
+ - industrial
10
+ - rotating-machinery
11
+ - time-series
12
+ - multivariate-time-series
13
+ - anndata
14
+ - vibframe
15
+ - vibsynth
16
  size_categories:
17
+ - 100K<n<1M
18
  ---
 
19
 
20
+ # DRMHB — Dynamic Rotating Machinery Health Benchmark
 
21
 
22
+ > **Status: pre-release.**
23
+ > The benchmark definition, source VibFrame and AnnData conversion pipeline are in the final validation stage. Public data artifacts will be uploaded after the final consistency checks.
24
 
25
+ > **VibFrame → AnnData tooling:** the companion package [`vibframe-anndata`](https://413hq.github.io/vibframe-anndata-docs/latest/) provides the supported conversion workflow from VibFrame to AnnData. The repository file `createanndata.py` is a minimal example that creates a **featureless AnnData** from the raw VibFrame, preserving the raw signal representation so that features can be materialized later. For the full API, configuration options and processing semantics, see the [package documentation](https://413hq.github.io/vibframe-anndata-docs/latest/).
26
 
27
+ **DRMHB** is a synthetic benchmark for machine-learning research in **condition monitoring of rotating machinery**. It represents **180 days of operation of a fleet of 12 nominally equivalent variable-speed motor–centrifugal-pump units**, with machine individuality, multiple normal operating regimes, dynamic transitions, healthy out-of-distribution operation and progressive mechanical degradation.
28
 
29
+ The benchmark is designed primarily for:
30
 
31
+ - unsupervised and semi-supervised anomaly detection;
32
+ - normality modelling under multiple operating regimes;
33
+ - early fault detection;
34
+ - machine-to-machine generalisation;
35
+ - domain shift across nominally equivalent assets;
36
+ - healthy-OOD versus mechanical-fault discrimination;
37
+ - progressive and interacting fault analysis;
38
+ - vibration representation learning;
39
+ - waveform/spectrum feature engineering;
40
+ - temporal and streaming evaluation.
41
+
42
+ All measurements are **synthetic**. DRMHB is not presented as field data and should not be interpreted as a substitute for validation on real industrial machinery.
 
 
 
 
 
 
 
 
43
 
44
  ---
45
 
46
  ## Industrial scenario
47
 
48
+ DRMHB simulates a standardised fleet of **12 variable-speed centrifugal motor–pump units**, identified as `M01` to `M12`.
49
 
50
+ Each unit represents the same equipment class:
51
 
52
  ```text
53
+ Variable-frequency drive (VFD)
54
  │
55
  Electric motor
56
  │
57
+ Mechanical coupling
58
  │
59
  Centrifugal pump
60
  │
61
  Process line
62
  ```
63
 
64
+ The monitored location is the **pump drive-end bearing housing**, with three vibration directions:
 
 
65
 
66
  - `pump_DE_H` — radial horizontal;
67
  - `pump_DE_V` — radial vertical;
68
  - `pump_DE_A` — axial.
69
 
70
+ The machines share the same nominal architecture, but small deterministic variations are applied to parameters such as structural response, damping, transfer gains and degradation parameters. They are therefore members of the same fleet rather than numerical clones.
71
+
72
+ The synthetic vibration source is **VibSynth**, developed by TWave. The source data are exported using the **VibFrame 0.2.0** contract and subsequently converted to AnnData for machine-learning workflows.
73
 
74
  ---
75
 
76
+ ## Time horizon and acquisition cadence
77
+
78
+ The simulated interval is:
79
+
80
+ **2026-01-01 00:00:00 UTC → 2026-06-29 23:40:00 UTC**
81
+
82
+ for a total of **180 days**.
83
 
84
+ A snapshot is produced every **20 minutes**:
85
 
86
+ - **12,960 snapshots per machine**;
87
+ - **155,520 fleet-level snapshots**.
88
 
89
+ The temporal history is divided into three intended evaluation regions:
90
 
91
+ | Region | Approx. days | Content | Intended use |
92
+ |---|---:|---|---|
93
+ | Calibration | 0–30 | Healthy operation | Learn normality |
94
+ | Normal holdout | 31–45 | Healthy unseen operation | Threshold calibration / false-positive analysis |
95
+ | Future stream | 46–180 | Healthy operation, transitions, OOD and progressive faults | Streaming evaluation |
96
+
97
+ Random row-wise train/test splits are discouraged because neighbouring samples from the same evolving machine are strongly related.
98
 
99
+ ---
100
 
101
+ ## Multi-regime normality
 
 
 
 
 
 
102
 
103
+ The fleet operates under several legitimate process conditions.
104
 
105
+ The scenario includes five regime families:
106
 
107
+ | ID | Name | Interpretation |
108
+ |---|---|---|
109
+ | `R1` | ECO | Reduced-demand / reduced-speed operation |
110
+ | `R2` | NOMINAL | Standard production duty |
111
+ | `R3` | PEAK | Temporary high-demand operation |
112
+ | `R4` | THROTTLED | Similar rotational speed to nominal operation but different hydraulic load |
113
+ | `R5` | RECIRCULATION | Low-flow / recirculation-type operation |
114
 
115
+ Not every machine uses every regime. This intentionally creates **partially shared operating domains** across the fleet.
 
 
 
 
 
 
 
 
 
 
 
 
 
116
 
117
+ A key property of the benchmark is that normal behaviour is **not reducible to rotational speed alone**. Different hydraulic/process states can occupy similar RPM regions while producing different vibration responses.
118
 
119
  ---
120
 
121
+ ## Dynamic operating transitions
122
+
123
+ Operating transitions are treated as part of **healthy normality**.
124
 
125
+ The revised scenario does not move between regimes using a simple direct interpolation of speed and load. Instead, the truth contains dynamic state variables such as:
126
+
127
+ - commanded speed;
128
+ - true rotational speed;
129
+ - speed rate;
130
+ - true load;
131
+ - flow;
132
+ - valve position;
133
+ - torque;
134
+ - thermal state;
135
+ - recirculation / low-flow instability state.
136
 
137
+ These variables evolve with lag and memory, allowing forward and reverse transitions to follow different trajectories.
138
 
139
+ The current 180-day fixture contains **22,179 transition snapshots**, approximately 14% of the complete stream.
140
 
141
+ This is intentional: a health detector should not raise an alarm merely because a healthy asset is accelerating, decelerating or changing process duty.
142
 
143
  ---
144
 
145
+ ## Signal acquisition
146
 
147
+ Each snapshot contains both spectral and time-domain information.
148
 
149
+ ### Spectra
150
 
151
+ For each machine and timestamp, spectra are available for all three monitored directions and two processing modes:
152
 
153
+ - `VEL_1K` — velocity spectrum, 0–1,000 Hz;
154
+ - `ACC_10K` — acceleration spectrum, 0–10,000 Hz.
155
 
156
+ Each spectrum contains **1,601 bins**.
 
 
 
 
157
 
158
+ This gives:
159
 
160
+ - 6 spectra per snapshot;
161
+ - **933,120 spectral signals** across the complete fleet.
162
 
163
+ ### Waveforms
164
 
165
+ Unlike the earlier development fixture, the current DRMHB revision contains a synchronized triaxial acceleration waveform at **every snapshot**.
166
 
167
+ The waveform sampling rate is:
168
 
169
+ **51.2 kHz**
170
 
171
+ For storage efficiency, steady/quasi-steady snapshots persist approximately **1.8 shaft revolutions** rather than the complete acquisition buffer.
172
 
173
+ Measured on the current AnnData fixture:
 
174
 
175
+ - **155,520 waveform snapshots**;
176
+ - **466,560 waveform channels/signals**;
177
+ - **2,107,792,704 waveform samples**;
178
+ - median stored length ≈ **3,825 samples**;
179
+ - median stored duration ≈ **74.7 ms**;
180
+ - median stored shaft coverage ≈ **1.800 revolutions**.
181
 
182
+ Because the stored duration follows shaft period, slower operating points contain more waveform samples than faster ones.
183
 
184
+ ### Waveform-first spectral generation
 
 
 
185
 
186
+ The short stored waveform is **not** used to approximate the high-resolution spectrum.
187
 
188
+ The generation chain is:
189
 
190
+ ```text
191
+ physical / operating state
192
+ ↓
193
+ full internal waveform acquisition
194
+ ├── high-resolution spectral products
195
+ └── persisted short waveform slice
196
+ ```
197
 
198
+ The spectrum and persisted waveform therefore originate from the **same simulated acquisition context and physical state**, while the short 1.8-revolution slice is retained primarily for time-domain ML, transient morphology and compact raw-signal studies.
 
 
199
 
200
+ The FFT of the stored short slice is not expected to reproduce the persisted high-resolution spectrum.
201
 
202
+ ### Synthetic tachometer information
203
+
204
+ The AnnData raw representation also stores synchronized tachometer edge information associated with the waveforms, enabling order-aware and shaft-referenced analyses without requiring RPM to be inferred only from the vibration signal.
205
 
206
  ---
207
 
208
+ ## Progressive fault modelling
209
 
210
+ Mechanical degradation is not represented only by a generic monotonic amplitude curve.
211
 
212
+ Each fault family carries its own physical or semi-physical latent state, and the observable vibration response depends on both that state and the current operating condition.
213
 
214
+ The simulated fault families are:
215
 
216
+ ### Imbalance
217
 
218
+ Imbalance is represented through an evolving unbalance state with magnitude and phase. Its observable 1X response depends on shaft speed and the structural transfer path rather than on a direct `severity × constant` rule.
 
 
 
 
 
 
 
 
 
 
 
 
 
219
 
220
+ ### Angular misalignment
221
 
222
+ Angular misalignment includes a geometric misalignment state coupled to operating load and thermal history. This introduces memory and regime dependence into the resulting harmonic response.
223
 
224
+ ### Bearing inner- and outer-race degradation
225
 
226
+ Bearing faults use a progressive defect state with crack/spall-like evolution and impact/ring-down behaviour. The resulting BPFO/BPFI-related observables are intentionally not perfectly monotonic with latent degradation.
227
 
228
+ ### Mechanical looseness
229
 
230
+ Looseness evolves through support/preload and clearance-related states. Intermittent impacts emerge from the nonlinear contact condition rather than from a purely time-based on/off schedule.
231
 
232
+ ### Resonance
233
 
234
+ Resonance is represented through evolving structural parameters such as effective natural frequency, damping and frequency ratio. Observable vibration can increase strongly near a resonance crossing and decrease again even while the underlying degradation state continues to evolve.
235
 
236
+ ### Interacting faults
 
 
 
 
237
 
238
+ Some machines contain two simultaneous mechanisms. These are not intended to behave as two completely independent additive labels; the simulated physical states can influence the manifestation or evolution of the other mechanism.
239
 
240
  ---
241
 
242
+ ## Fault distribution
243
 
244
+ Three machines remain mechanically healthy throughout the full horizon, while the remaining units develop one or two progressive faults.
245
 
246
+ | Machine | Fault 1 | Fault 2 |
247
+ |---|---|---|
248
+ | `M01` | Imbalance | — |
249
+ | `M02` | Healthy | — |
250
+ | `M03` | Angular misalignment | — |
251
+ | `M04` | Bearing outer-race fault | — |
252
+ | `M05` | Imbalance | Bearing outer-race fault |
253
+ | `M06` | Mechanical looseness | — |
254
+ | `M07` | Healthy | — |
255
+ | `M08` | Angular misalignment | Mechanical looseness |
256
+ | `M09` | Bearing inner-race fault | — |
257
+ | `M10` | Bearing inner-race fault | Resonance |
258
+ | `M11` | Healthy | — |
259
+ | `M12` | Resonance | — |
260
 
261
+ The evaluation sidecar preserves the separate state and severity of each active mechanism.
262
 
263
  ---
264
 
265
+ ## Healthy operational OOD
266
 
267
+ Not every unusual observation is a fault.
268
 
269
+ DRMHB contains deliberately unusual operating periods on machines that remain mechanically healthy. These events are outside the normal calibration operating distribution but are not degradation.
270
 
271
+ This allows evaluation of the distinction:
272
 
273
+ ```text
274
+ statistical novelty ≠ mechanical fault
275
+ ```
 
 
 
 
276
 
277
+ A useful health-monitoring model should ideally remain sensitive to progressive mechanical degradation without treating every unseen speed/load combination or legitimate process transition as a fault.
278
 
279
  ---
280
 
281
+ ## Ground truth
282
 
283
+ The source VibFrame stores evaluation truth separately from the learning representation.
284
+
285
+ The current snapshot truth contains **155,520 aligned rows across 12 machine partitions** and includes both high-level labels and detailed latent states.
286
+
287
+ Examples include:
288
 
289
  - machine identity;
290
+ - temporal split;
291
  - operating regime;
292
+ - transition flag, origin, destination and progress;
293
+ - commanded and true speed;
294
+ - speed rate;
295
+ - load;
296
+ - flow;
297
+ - valve position;
298
+ - torque;
299
+ - thermal state;
300
+ - recirculation state;
301
+ - healthy OOD flag;
302
+ - fault type and severity;
303
+ - mechanism-specific physical states;
304
+ - selected truth-side diagnostic observables;
305
  - reproducibility seed.
306
 
307
+ The current truth representation contains **89 columns** after expanding mechanism-specific physical-state payloads in the reference EDA.
308
+
309
+ ### Leakage warning
310
+
311
+ Ground truth is provided for **evaluation, interpretation and reproducibility**.
312
 
313
+ Fields such as:
314
 
315
+ - `health_state`;
316
+ - `fault_*`;
317
+ - latent physical degradation state;
318
+ - `ood_operational`;
319
+ - evaluation split information;
320
 
321
+ must not automatically be used as model inputs in unsupervised anomaly-detection experiments.
322
 
323
  ---
324
 
325
+ ## Dataset scale
326
+
327
+ Current validated AnnData geometry:
328
+
329
+ | Item | Value |
330
+ |---|---:|
331
+ | Machines | 12 |
332
+ | Duration | 180 days |
333
+ | Snapshot cadence | 20 min |
334
+ | Snapshots per machine | 12,960 |
335
+ | Fleet snapshots | 155,520 |
336
+ | Spectral signals | 933,120 |
337
+ | Spectral bins per signal | 1,601 |
338
+ | Waveform snapshots | 155,520 |
339
+ | Waveform signals | 466,560 |
340
+ | Waveform samples | 2,107,792,704 |
341
+ | Waveform sample rate | 51.2 kHz |
342
+ | Median stored waveform | ~1.8 shaft revolutions |
343
+ | Transition snapshots | 22,179 |
344
+ | Base featureless AnnData size | ~13.85 GiB |
345
+ | Base AnnData feature matrix | `(155520, 0)` |
346
+
347
+ The base `.h5ad` intentionally contains **no derived features in `X`**. Features can be materialized incrementally from the persisted raw representations.
348
+
349
+ ---
350
+
351
+ ## AnnData representation
352
 
353
+ The reference machine-learning artifact is a featureless raw AnnData representation generated with `vibframe-anndata`.
354
+
355
+ Conceptually:
356
 
357
  ```text
358
+ obs
359
+ ├── snapshot metadata
360
+ ├── machine
361
+ ├── timestamp
362
+ ├── speed
363
+ └── signal-availability flags
364
+
365
+ X
366
+ └── initially (n_snapshots, 0)
367
+
368
+ var
369
+ └── feature metadata after feature materialization
370
+
371
+ obsm
372
+ ├── raw_spectra
373
+ ├── raw_spectra_lengths
374
+ ├── raw_spectra_positions
375
+ ├── raw_spectra_speed_hz
376
+ ├── raw_waveforms
377
+ ├── raw_waveforms_lengths
378
+ ├── raw_waveforms_positions
379
+ ├── raw_waveforms_speed_hz
380
+ ├── raw_waveforms_tacho_rising
381
+ └── raw_waveforms_tacho_falling
382
+
383
+ uns
384
+ └── VibFrame / machine / channel / provenance metadata
385
  ```
386
 
387
+ Derived features can be added later without reopening the original VibFrame archive.
388
+
389
+ ---
390
+
391
+ ## Recommended evaluation protocol
392
+
393
+ The benchmark is designed around **temporal normality modelling**.
394
+
395
+ A recommended anomaly-detection protocol is:
396
+
397
+ 1. fit preprocessing and models only on the healthy calibration period;
398
+ 2. use the normal holdout period for threshold calibration;
399
+ 3. evaluate once on the future stream;
400
+ 4. count healthy transitions as normal;
401
+ 5. count healthy OOD operation as normal unless the research question explicitly concerns novelty detection;
402
+ 6. report both classification/ranking quality and detection timing.
403
+
404
+ Useful metrics include:
405
 
406
+ - AUROC;
407
+ - AUPRC;
408
+ - F1;
409
+ - false-positive rate on ordinary healthy operation;
410
+ - false-positive rate during healthy transitions;
411
+ - false-positive rate during healthy OOD;
412
+ - detection delay;
413
+ - severity at first sustained detection;
414
+ - per-machine and per-fault performance.
415
+
416
+ ---
417
+
418
+ ## Compact reference baseline
419
+
420
+ The reference EDA includes four deliberately simple unsupervised baselines.
421
+
422
+ All models are fitted only on calibration data. Thresholds are set using the **99th percentile of normal-holdout anomaly scores** and then evaluated on the future stream.
423
+
424
+ | Model | AUROC | AUPRC | F1 | Healthy FPR | Transition FPR | OOD FPR | Median delay |
425
+ |---|---:|---:|---:|---:|---:|---:|---:|
426
+ | Robust distance | 0.792 | 0.815 | 0.360 | 1.03% | 0.83% | 0.00% | 8.11 d |
427
+ | PCA reconstruction | 0.825 | 0.865 | 0.600 | 0.76% | 0.72% | 0.99% | 10.54 d |
428
+ | Isolation Forest | **0.884** | **0.920** | **0.773** | 1.39% | 4.44% | 2.38% | 3.61 d |
429
+ | One-Class SVM | 0.775 | 0.848 | 0.679 | 0.84% | 2.68% | 4.96% | **1.65 d** |
430
+
431
+ These numbers are intended as a **sanity-check baseline, not a leaderboard**.
432
+
433
+ They illustrate a useful property of DRMHB: different simple models exhibit different trade-offs between early detection, transition robustness and OOD robustness.
434
+
435
+ ---
436
+
437
+ ## Evidence of non-trivial healthy structure
438
+
439
+ The reference EDA also checks whether healthy operation collapses into a trivially low-dimensional manifold.
440
+
441
+ Using a compact engineered feature representation on healthy calibration data:
442
+
443
+ - 10 principal components are required for 80% explained variance;
444
+ - 14 for 90%;
445
+ - 17 for 95%;
446
+ - a TwoNN intrinsic-dimension estimate gives approximately **12.15**.
447
+
448
+ This does not prove industrial realism, but it provides evidence that the benchmark's healthy operating space is not simply a one- or two-dimensional RPM trajectory.
449
 
450
  ---
451
 
452
  ## Suggested research uses
453
 
454
+ DRMHB is particularly suitable for research on:
455
 
456
+ - unsupervised anomaly detection;
457
+ - semi-supervised health monitoring;
458
  - one-class learning;
459
+ - early fault detection;
460
+ - progressive-fault modelling;
461
+ - machine-invariant representation learning;
462
+ - fleet-level normality modelling;
463
+ - domain generalisation;
464
+ - regime-conditioned anomaly detection;
465
+ - transition-aware monitoring;
466
+ - healthy-OOD discrimination;
467
+ - interacting faults;
468
+ - raw waveform learning;
469
  - spectral representation learning;
470
+ - order-aware vibration analysis;
471
+ - classical feature engineering;
472
+ - explainable condition monitoring;
473
+ - temporal benchmark methodology.
 
474
 
475
  ---
476
 
477
  ## Important limitations
478
 
479
+ DRMHB is a controlled synthetic benchmark and has important limitations:
480
 
481
+ 1. **All measurements are synthetic.**
 
 
482
  2. The plant and its operating history are fictitious.
483
+ 3. The simulated motor–pump train represents an equipment class rather than a digital twin of one specific commercial machine.
484
+ 4. Reduced physical and semi-physical models cannot reproduce every structural, hydraulic, tribological, electrical or environmental non-linearity present in a real plant.
485
+ 5. The stored ~1.8-revolution waveform is intentionally short and is **not** a substitute for the high-resolution spectrum.
486
+ 6. Spectral and waveform products are generated from the same acquisition context, but users should follow the documented processing semantics rather than assume arbitrary signal-processing equivalence.
487
+ 7. Ground truth is unusually complete because the scenario is simulated; real deployments do not provide this level of observability.
488
+ 8. Benchmark performance must not be interpreted as evidence of production readiness.
489
+ 9. Findings should ideally be validated on independent field datasets before making claims about real industrial performance.
490
 
491
  ---
492
 
493
+ ## Reproducibility
494
 
495
+ The scenario is deterministic from a master seed and derived sub-seeds.
496
 
497
+ The reference scenario uses:
498
 
499
+ ```text
500
+ 20260910
501
+ ```
502
+
503
+ Sub-seeds are derived for machine identity, operating dynamics, degradation mechanisms and signal realizations.
504
 
505
+ The aim is to make the benchmark reproducible while retaining machine-to-machine and snapshot-to-snapshot variability.
506
 
507
  ---
508
 
509
+ ## Provenance
510
+
511
+ DRMHB was generated with **VibSynth**, synthetic vibration generation tooling developed by **TWave**, and serialized using **VibFrame 0.2.0**.
512
+
513
+ The AnnData representation is produced through the `vibframe-anndata` conversion pipeline.
514
 
515
+ The benchmark was developed in the context of collaboration involving:
516
+
517
+ - TWave;
518
+ - University of Oviedo;
519
+ - Fundación Universidad de Oviedo.
520
+
521
+ ---
522
+
523
+ ## Repository status
524
 
525
  - [x] Industrial scenario defined
526
+ - [x] Dynamic multi-regime simulation generated
527
+ - [x] Waveform-first signal generation enabled
528
+ - [x] Dense waveform acquisition validated
529
+ - [x] Dynamic transitions validated
530
+ - [x] Progressive physical/semi-physical fault states validated
531
+ - [x] Ground-truth alignment validated
532
+ - [x] VibFrame → AnnData conversion validated
533
+ - [x] Reference EDA executed
534
+ - [x] Compact ML baseline executed
535
+ - [ ] Final public artifacts uploaded
536
+ - [ ] Loading examples finalized
537
+ - [ ] License finalized
538
+ - [ ] First public release tagged
539
 
540
  ---
541
 
542
  ## Citation
543
 
544
+ A formal publication citation will be added if/when a corresponding paper is released.
545
 
546
+ For preliminary use, cite the dataset repository and make its synthetic nature explicit.
547
 
548
  ```bibtex
549
+ @dataset{drmhb_2026,
550
+ title = {DRMHB: Dynamic Rotating Machinery Health Benchmark},
551
+ author = {Gonzalez Zapico, Alejandro},
552
+ year = {2026},
553
+ publisher = {Hugging Face},
554
+ note = {Synthetic rotating-machinery health-monitoring benchmark generated with VibSynth by TWave}
555
  }
556
  ```
557
 
558
  ---
559
 
 
 
 
 
 
 
 
 
560
  ## License
561
 
562
  **To be defined before the first public release.**
563
 
564
+ No reuse rights should be inferred until an explicit dataset license is added to the repository metadata.
565
 
566
  ---
567
 
568
+ ## Contact and reporting results
569
 
570
+ Questions and reproducibility reports are welcome through the repository discussions.
571
 
572
+ When reporting results, please state:
573
 
 
 
574
  - which temporal split was used;
575
+ - whether the model was trained only on calibration data;
576
+ - whether raw spectra, waveforms or derived features were used;
577
+ - whether RPM, regime or other operating metadata were supplied to the model;
578
+ - whether healthy transitions were considered normal;
579
+ - whether healthy OOD periods were considered normal or anomalous;
580
+ - whether evaluation was per-machine or fleet-level;
581
+ - how detection delay was defined.