text
stringlengths
0
1.99k
Date: 5:06 pm Tue May 05, 1987
June 19-21 (Fri-Sun), 1987. The Executive International Best Western Hotel
(Airport). For all phreakers and hackers that feel so inclined as to attend.
Its like an open party.
:Knight Lightning
38/100: Advanced Carding Series
Name: The Disk Jockey 13
Date: 12:33 am Wed May 06, 1987
Most of my advanced carding series and some other fraud files I have written
in ARCed and on the AE line. Look for ADVCARD.ARC.
-The Disk Jockey
39/100: WELL...
Name: Sir Francis Drake 56
Date: 1:14 am Wed May 06, 1987
AS FOOR ID TAGS, JUST LOOK FOR THE GUY WITH THE NOSE RING...HA, JUST *TR
Y* TO
IMPERSONATE THAT.
(OF COURSE IF I DONT GO, 'LOOKING FOR THE GUY WITH THE NOSE RING' COULD
BECOME QUITE TEDIOUS)
SFD
40/100: Adv Carding files
Name: Taran King 1
Date: 7:50 pm Wed May 06, 1987
They are now integrated in the anarchy subdirectory (because they're hardly
phreak/hack but not really "general"). They include ADVCARD*.TXT,
CHECKFRD.TXT, ATMFRAUD.TXT and maybe one or two I forgot, but Jockey can fill
you in. Snort the wave...
-TK
41/100: Anyone
Name: Knight Lightning 2
Date: 12:28 am Thu May 07, 1987
Did anyone ever get in touch with Sherlock Holmes on P-80?
:Knight Lightning
42/100: well...
Name: Sir Francis Drake 56
Date: 6:07 pm Thu May 07, 1987
Hmm, one thing I found trashing quite awhile ago was a report by Pac-Bell on
problems they were having with their new DMS-100's...One thing was the "coin
problems"...Ill quote the letter as its fairly interesting:
Four coin problems have been discovered with the introduction of the DMS-100
in Pacific Bell. These are:
1. Applied +48 Volts for Coin Presence Test
2. Coin Return Voltage
3. Paramater - Per call ground loop detection test
4. Overheating of GX18AB cards Real clever name there..(Did ya get the pun?)
+48 Volts associated with coin service is used for Coin Overtime, Coin Presence
Tests and Automatic Coin Toll Service (ACTS). +48V is used in ACTS to reset
the totalizer so that coin counting can be acomplished. NT has developed a
workaround for interfacing to ACTS. Therefore the main problem is the coin
presence test. In normal situations, battery is applied to Tip side with the
ring side opened. +48V is applied to the ring sing of the line which detects
the presence of a coin or no coin. If no ground condition exists, no coin is
present. If a coin is stuck (ground condition) a line 112 report will print in
the CO.
Without +48V this cannout be done.
In a situation where a customer deposits .20 cents on a call requiring a .50
cent deposit, the .20 cent deposit is not being returned. The TSPS machine,
handling all call processing, will instruct the End Office to sent out voltage
(Normal +110 Volts for collect and -110 for return) that will return the inital
deposit. ACTS then resets the totalizer which enables coin counting to begin
on the initiation of the required .50 cent deposit. Presently, the DMS is not
doing this.
well whatever.
sfd
43/100: well...
Name: Sir Francis Drake 56