text stringlengths 0 1.99k |
|---|
44/70: Addition. |
Name: Phantom Phreaker 46 |
Date: 2:32 am Sat May 09, 1987 |
(I forgot something) |
DMS-100 does have something like it's own call blocking. It can be used to |
restrict certain types of lines from calling other types. The destination |
switch checks the information sent in from the (intraoffice) DN, (I think the |
Screening Code, probably) or from an INC (incoming trunk). This can be done to |
restrict access to official lines and such. |
Phantom |
45/70: i thought |
Name: Lucifer 666 43 |
Date: 2:26 am Sun May 10, 1987 |
none of the DMS features blocking other people from calling you, etc| were |
not implemented.... I thought that the user-choice stuff was never put in... |
was I wrong? |
L666 |
46/70: RC15? |
Name: Control C 8 |
Date: 11:17 am Sun May 10, 1987 |
Phantom, |
Are you sure the RC15 exists? RC's start at 16 and end at 29.. |
Maby I'm just screwed... |
47/70: FACS |
Name: Mad Hatter 51 |
Date: 5:57 pm Tue May 12, 1987 |
Can anyone fill me in on FACS? I got the file by Sharp Razor and Doom Prophet |
has told me about it somewhat, but can anyone explain detailed info on it? |
Thanks (d00d)... |
-Hatter |
.s |
48/70: TC15 |
Name: Phantom Phreaker 46 |
Date: 7:21 pm Tue May 12, 1987 |
Actually, it's a TC15 report on a 1AESS... not RC15. Sorry about that. A TC15 |
is very long and has a few acronyms in it that I don't recognize. About the |
only one I can remember right now was PUC, Peripheral Unit Controller. |
For those of you who have problems with the acronyms posted here, you might |
want to check the N)eed acronyms option from the main menu on this board. This |
is an acronym list that I made a while back and gave to TK, and he put a few |
in himself. It's basically correct as far as I know, so please let's not add |
one unless you are sure. |
Phantom |
49/70: Carot, etc. |
Name: Doom Prophet 21 |
Date: 4:41 pm Fri May 15, 1987 |
Well, I don't know that much about FACS, although I don't believe that it |
really acts as a replacement for COSMOS, more like an integration/mini datakit |
sort of thing for the different systems related to cosmos. |
Mad Hatter was asking about CAROT in mail, and I looked through some stuff and |
here is some info about the system. It consists of the two processors for the |
CAROT (database section), the data and the test processor. The TP controls and |
directs the ROTL's and the Circuit Maintenance System (I've seen CMS-1B and |
also CMS-3A, don't know what the current version is). CMS 3A is used with |
TIRKS also. Anyway, the CAROT controller (which is supported by the two |
processors) can do something like 14 tests at the same time (at night when |
their is less traffic on the trunks). The CC also analyzes and sends out the |
test results to the appropriate departments or offices (the CO, an SCC or a |
CTTU station). The ROTL is accessed just by the technician dialing it, which |
is why anyone can dial them. The ROTL is controlled by MF input of the trunk |
group and network numbers. I have seen TNN's as being three digits, but I |
guess it depends upon the office size. The ROTL seizes the trunk to be tested. |
The ATMS responder (Automated Trunk Measurement System) is connected to the |
ends of the tested trunk to receive tthe test measurements. The ROTL somehow |
Subsets and Splits
No community queries yet