@@ -4,26 +4,22 @@ This dataset contains the electrical power measurements for the virtual meter an
4
 
5
  # Use Case
6
 
7
- Virtual Meter integrated in a **host** device on a dedicated (for example: an EV charger, a battery, a heatpump...) or shared (for example: plugin battery or heater) circuit
8
 
9
  ---
10
 
11
  # Test Setup
12
 
13
- * **Grid Setup:** Single-phase electrical system, behind an isolating transformer, TN earthing with neutral-earth bond at transformer terminals
14
  * **Reference Meter:** [Shelly 3EM](shelly-3EM-datasheet.pdf), using split core CTs, class B with ~1% accuracy
15
- * **Calibration:** Calibration was performed manually, mapping the voltage drop to the reference power, to set the scaling factor for the virtual meter.
16
-
17
- | LAB1 (artificial loads) | LAB2 (appliances) |
18
- | :--- | :--- |
19
- | Random sequence of artificial resistive, inductive and capacitive loads, automated with Shelly devices controlled by a Python script | Sequence of real appliances, simulating a real household, automated with Shelly devices controlled by a Python script |
20
- | <img src="lab1-picture.png" width="600"> | <img src="lab2-picture.png" width="600"> |
21
 
22
  ---
23
 
24
  # Limitations
25
 
26
- * **Artificial Environment:** Because it uses an isolating tranformer and artificial loads, it may not capture some of the noise experienced in real-world environments.
27
  * **Manual Calibration:** The accuracy is dependent on the manual mapping performed against the Shelly 3EM. Other methods are under development to perform calibration through automation.
28
 
29
  ---
 
4
 
5
  # Use Case
6
 
7
+ Virtual Meter integrated in a host device on a dedicated (for example: an EV charger, a battery, a heatpump...) or shared (for example: plugin battery or heater) circuit.
8
 
9
  ---
10
 
11
  # Test Setup
12
 
13
+ * **Grid Setup:** Single-phase or Three-phase electrical system, TN earthing with neutral-earth bond at grid connection point
14
  * **Reference Meter:** [Shelly 3EM](shelly-3EM-datasheet.pdf), using split core CTs, class B with ~1% accuracy
15
+ * **Calibration:** Calibration was performed manually, mapping the voltage drop to the reference power, to set the scaling factor for the virtual meter.
16
+ * **Loads:** Common household loads (mix of resistive, inductive and capacitive) activated for 10-20 sec (hotplate, oven, dryer, drill, microwave, etc...)
 
 
 
 
17
 
18
  ---
19
 
20
  # Limitations
21
 
22
+ * **Accelerated Testing:** The loads are activated and the measurements are recorded within an accelerated 20 min period. The ratio of base to peak loads in skewed in favour of peak loads.
23
  * **Manual Calibration:** The accuracy is dependent on the manual mapping performed against the Shelly 3EM. Other methods are under development to perform calibration through automation.
24
 
25
  ---