@@ -4,26 +4,22 @@ This dataset contains the electrical power measurements for the virtual meter an
|
|
| 4 |
|
| 5 |
# Use Case
|
| 6 |
|
| 7 |
-
Virtual Meter integrated in a
|
| 8 |
|
| 9 |
---
|
| 10 |
|
| 11 |
# Test Setup
|
| 12 |
|
| 13 |
-
* **Grid Setup:** Single-phase electrical system,
|
| 14 |
* **Reference Meter:** [Shelly 3EM](shelly-3EM-datasheet.pdf), using split core CTs, class B with ~1% accuracy
|
| 15 |
-
* **Calibration:** Calibration was performed manually, mapping the voltage drop to the reference power, to set the scaling factor for the virtual meter.
|
| 16 |
-
|
| 17 |
-
| LAB1 (artificial loads) | LAB2 (appliances) |
|
| 18 |
-
| :--- | :--- |
|
| 19 |
-
| Random sequence of artificial resistive, inductive and capacitive loads, automated with Shelly devices controlled by a Python script | Sequence of real appliances, simulating a real household, automated with Shelly devices controlled by a Python script |
|
| 20 |
-
| <img src="lab1-picture.png" width="600"> | <img src="lab2-picture.png" width="600"> |
|
| 21 |
|
| 22 |
---
|
| 23 |
|
| 24 |
# Limitations
|
| 25 |
|
| 26 |
-
* **
|
| 27 |
* **Manual Calibration:** The accuracy is dependent on the manual mapping performed against the Shelly 3EM. Other methods are under development to perform calibration through automation.
|
| 28 |
|
| 29 |
---
|
|
|
|
| 4 |
|
| 5 |
# Use Case
|
| 6 |
|
| 7 |
+
Virtual Meter integrated in a host device on a dedicated (for example: an EV charger, a battery, a heatpump...) or shared (for example: plugin battery or heater) circuit.
|
| 8 |
|
| 9 |
---
|
| 10 |
|
| 11 |
# Test Setup
|
| 12 |
|
| 13 |
+
* **Grid Setup:** Single-phase or Three-phase electrical system, TN earthing with neutral-earth bond at grid connection point
|
| 14 |
* **Reference Meter:** [Shelly 3EM](shelly-3EM-datasheet.pdf), using split core CTs, class B with ~1% accuracy
|
| 15 |
+
* **Calibration:** Calibration was performed manually, mapping the voltage drop to the reference power, to set the scaling factor for the virtual meter.
|
| 16 |
+
* **Loads:** Common household loads (mix of resistive, inductive and capacitive) activated for 10-20 sec (hotplate, oven, dryer, drill, microwave, etc...)
|
|
|
|
|
|
|
|
|
|
|
|
|
| 17 |
|
| 18 |
---
|
| 19 |
|
| 20 |
# Limitations
|
| 21 |
|
| 22 |
+
* **Accelerated Testing:** The loads are activated and the measurements are recorded within an accelerated 20 min period. The ratio of base to peak loads in skewed in favour of peak loads.
|
| 23 |
* **Manual Calibration:** The accuracy is dependent on the manual mapping performed against the Shelly 3EM. Other methods are under development to perform calibration through automation.
|
| 24 |
|
| 25 |
---
|