Datasets:

License:
ozanbarism commited on
Commit
8e7837f
·
verified ·
1 Parent(s): 62e4bdf

Update README.md

Browse files
Files changed (1) hide show
  1. README.md +65 -3
README.md CHANGED
@@ -1,3 +1,65 @@
1
- ---
2
- license: apache-2.0
3
- ---
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
+ ---
2
+ license: apache-2.0
3
+ ---
4
+ ---
5
+ tags:
6
+ - energy disaggregation
7
+ - non-intrusive load monitoring
8
+ - time series
9
+ - electrical load monitoring
10
+ license: unknown # License information was not explicitly stated in the paper, might need clarification.
11
+ language:
12
+ - en
13
+ pretty_name: BLUED (Building-Level fUlly-labeled dataset for Electricity Disaggregation)
14
+ ---
15
+
16
+ # Dataset Card for BLUED
17
+
18
+ ## Dataset Description
19
+
20
+ BLUED (Building-Level fUlly-labeled dataset for Electricity Disaggregation) is a public dataset designed for event-based Non-Intrusive Load Monitoring (NILM) research. It contains high-frequency voltage and current measurements from a single-family home in the United States over one week. The key feature of this dataset is the detailed labeling of appliance state transitions (events), providing ground truth for evaluating event-based disaggregation algorithms. The dataset aims to facilitate the development, testing, and comparison of NILM algorithms.
21
+
22
+ ## Dataset Details
23
+
24
+ * **Data Collection:**
25
+ * Data was collected over one week in October 2011 from a single-family house in Pittsburgh, Pennsylvania.
26
+ * Aggregate voltage and current measurements were captured at the main distribution panel using a National Instruments DAQ (NI USB-9215A) at a sampling rate of 12 kHz. Current was measured using split-core current transformers, and voltage was measured using a voltage transformer.
27
+ * Ground truth for appliance events was collected using a combination of plug-level power meters (FireFly sensors), environmental sensors (light, sound, vibration, etc.), and circuit-level current measurements.
28
+ * Events were defined as changes in power consumption greater than 30 watts lasting at least 5 seconds.
29
+ * Timestamps for ground truth events were manually synchronized with the aggregate power signal via visual inspection.
30
+ * **Data Content:**
31
+ * Raw voltage (one phase) and current (two phases) waveforms sampled at 12 kHz.
32
+ * Computed active power at 60 Hz.
33
+ * A list of timestamped events, identifying the appliance and the transition type (e.g., on/off).
34
+ * Covers approximately 50 electrical appliances, though not all were active or met the event criteria during the collection week.
35
+ * Includes 2,482 labeled events in total, with 2,355 attributed to known appliances and 127 from unknown sources (clustered into potentially 11 distinct appliances). Events are split between Phase A (904 events) and Phase B (1578 events).
36
+ * **Data Format:** Raw current and voltage files, along with a list of event timestamps. Active power computed at 60Hz is also included.
37
+ * **Data Splits:** The paper presents preliminary results using the whole week but suggests future work might involve splitting into training/testing sets.
38
+
39
+ ## Uses
40
+
41
+ * **Non-Intrusive Load Monitoring (NILM):** Primarily designed for developing and evaluating event-based energy disaggregation algorithms.
42
+ * **Appliance Usage Pattern Analysis:** Studying how and when different appliances are used in a residential setting.
43
+ * **Occupancy Detection:** Inferring household occupancy based on appliance usage.
44
+ * **Energy Management & Efficiency:** Developing strategies for residential energy savings.
45
+ * **Anomaly Detection & Fault Diagnostics:** Identifying unusual appliance behavior or potential faults.
46
+ * **Assisted Living Applications:** Monitoring activities of daily living through appliance usage.
47
+
48
+ ## Dataset Limitations
49
+
50
+ * **Duration:** One week of data may not capture the usage patterns of all appliances, especially seasonal ones (like the air conditioner) or those used infrequently (like the dryer).
51
+ * **Sensor Frequency Limitation:** The current sensors used had a cutoff frequency around 300 Hz, limiting the analysis of higher-frequency harmonics (beyond the 5th harmonic).
52
+ * **Incomplete Ground Truth:** Approximately 5% of events detected in the aggregate signal could not be attributed to the monitored appliances and are labeled as "unknown". Some appliances (~25%) had no registered events meeting the criteria during the collection week.
53
+ * **Single Home:** Data represents only one specific home and its occupants' behavior.
54
+
55
+ ## Citation
56
+
57
+ ```bibtex
58
+ @inproceedings{anderson2012blued,
59
+ title={BLUED: A fully labeled public dataset for event-based non-intrusive load monitoring research},
60
+ author={Anderson, Kyle and Ocneanu, Adrian and Benitez, Diego and Carlson, Derrick and Rowe, Anthony and Berg{\'e}s, Mario},
61
+ booktitle={Proceedings of the 2nd ACM SIGKDD international workshop on data mining applications in sustainability},
62
+ pages={1--8},
63
+ year={2012},
64
+ organization={ACM}
65
+ }