File size: 6,908 Bytes
61b55ca | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 | {
"table_description": "This table contains one row per CT Image Storage (SOPClassUID 1.2.840.10008.5.1.4.1.1.2) DICOM series in IDC, capturing acquisition and reconstruction parameters that are not included in the main idc_index table. The index can be joined to idc_index on SeriesInstanceUID to combine universal series metadata with CT-specific acquisition parameters. For XRayTubeCurrent, Exposure, and ExposureTime \u2014 which vary across instances within a series due to dose modulation \u2014 both min and max values are reported. All other attributes are aggregated with ANY_VALUE (one representative instance).",
"columns": [
{
"name": "SeriesInstanceUID",
"type": "STRING",
"mode": "NULLABLE",
"description": "DICOM SeriesInstanceUID \u2014 unique identifier of the CT series; use to join with idc_index"
},
{
"name": "ImageType",
"type": "STRING",
"mode": "REPEATED",
"description": "image type values as defined in DICOM ImageType attribute (e.g., ORIGINAL/DERIVED, PRIMARY/SECONDARY, AXIAL/LOCALIZER); aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "PixelSpacing_row_mm",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "in-plane pixel spacing along the row direction in mm, derived from DICOM PixelSpacing[0]; a subset of CT series have anisotropic spacing where this differs from PixelSpacing_col_mm; aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "PixelSpacing_col_mm",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "in-plane pixel spacing along the column direction in mm, derived from DICOM PixelSpacing[1]; a subset of CT series have anisotropic spacing where this differs from PixelSpacing_row_mm; aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "Rows",
"type": "INTEGER",
"mode": "NULLABLE",
"description": ""
},
{
"name": "Columns",
"type": "INTEGER",
"mode": "NULLABLE",
"description": ""
},
{
"name": "SliceThickness",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "nominal reconstructed slice thickness in mm as defined in DICOM SliceThickness attribute; aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "KVP",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "peak kilovoltage of the X-ray tube in kV as defined in DICOM KVP attribute; constant across instances \u2014 aggregated with ANY_VALUE"
},
{
"name": "ScanOptions",
"type": "STRING",
"mode": "REPEATED",
"description": "acquisition scan options as defined in DICOM ScanOptions attribute (e.g., HELICAL MODE, AXIAL MODE, SCOUT MODE); may contain multiple values; aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "ConvolutionKernel",
"type": "STRING",
"mode": "REPEATED",
"description": "reconstruction convolution kernel as defined in DICOM ConvolutionKernel attribute; vendor-specific string (e.g., B30f, STANDARD, LUNG); may contain multiple values; aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "GantryDetectorTilt",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "nominal angle of the scanning gantry in degrees as defined in DICOM GantryDetectorTilt attribute; non-zero for gantry-tilted acquisitions; constant across instances \u2014 aggregated with ANY_VALUE"
},
{
"name": "XRayTubeCurrent_min",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "minimum X-ray tube current in mA across all instances in the series, derived from DICOM XRayTubeCurrent attribute; equals XRayTubeCurrent_max for fixed-current acquisitions; lower than XRayTubeCurrent_max for dose-modulated acquisitions (MIN across all instances)"
},
{
"name": "XRayTubeCurrent_max",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "maximum X-ray tube current in mA across all instances in the series, derived from DICOM XRayTubeCurrent attribute; equals XRayTubeCurrent_min for fixed-current acquisitions; higher than XRayTubeCurrent_min for dose-modulated acquisitions (MAX across all instances)"
},
{
"name": "FilterType",
"type": "STRING",
"mode": "NULLABLE",
"description": "type of filter used in the acquisition as defined in DICOM FilterType attribute (e.g., WEDGE, BUTTERFLY, FLAT); constant across instances \u2014 aggregated with ANY_VALUE"
},
{
"name": "Exposure_min",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "minimum exposure in mAs across all instances in the series, derived from DICOM Exposure attribute; equals Exposure_max for fixed-exposure acquisitions; lower than Exposure_max for dose-modulated acquisitions (MIN across all instances)"
},
{
"name": "Exposure_max",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "maximum exposure in mAs across all instances in the series, derived from DICOM Exposure attribute; equals Exposure_min for fixed-exposure acquisitions; higher than Exposure_min for dose-modulated acquisitions (MAX across all instances)"
},
{
"name": "ExposureTime_min",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "minimum duration of the X-ray exposure in ms across all instances in the series, derived from DICOM ExposureTime attribute (MIN across all instances)"
},
{
"name": "ExposureTime_max",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "maximum duration of the X-ray exposure in ms across all instances in the series, derived from DICOM ExposureTime attribute (MAX across all instances)"
},
{
"name": "DataCollectionDiameter",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "diameter of the region over which data were collected in mm as defined in DICOM DataCollectionDiameter attribute; constant across instances \u2014 aggregated with ANY_VALUE"
},
{
"name": "ReconstructionDiameter",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "diameter of the reconstruction field of view in mm as defined in DICOM ReconstructionDiameter attribute; aggregated with ANY_VALUE \u2014 constant across instances within a series"
},
{
"name": "SpiralPitchFactor",
"type": "FLOAT",
"mode": "NULLABLE",
"description": "ratio of the beam pitch for helical CT as defined in DICOM SpiralPitchFactor attribute; NULL for non-helical (sequential/axial) acquisitions; constant across instances \u2014 aggregated with ANY_VALUE"
}
]
} |