File size: 313,570 Bytes
043dbdb
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
{"episode_index": 0, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 1, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 2, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 3, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 4, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 5, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 6, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 7, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 8, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 9, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 10, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 11, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 12, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 13, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 14, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 15, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 16, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 17, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 18, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 19, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 20, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 21, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 22, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 23, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 24, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 25, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 26, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 27, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 28, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 29, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 30, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 31, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 32, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 33, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 34, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 35, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 36, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 37, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 38, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 39, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 40, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 41, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 42, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 43, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 44, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 45, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 46, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 47, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 48, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 49, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 50, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 51, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 52, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 53, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 54, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 55, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 56, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 57, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 58, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 59, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 60, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 61, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 62, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 63, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 64, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 65, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 66, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 67, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 68, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 69, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 70, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 71, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 72, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 73, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 74, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 75, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 76, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 77, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 78, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 79, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 80, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 81, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 82, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 83, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 84, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 85, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 86, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 87, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 88, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 89, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 90, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 91, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 92, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 93, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 94, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 95, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 96, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 97, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 98, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 99, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 100, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 101, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 102, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 103, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 104, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 105, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 106, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 107, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 108, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 109, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 110, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 111, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 112, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 113, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 114, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 115, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 116, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 117, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 118, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 119, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 120, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 121, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 122, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 123, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 124, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 125, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 126, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 127, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 128, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 129, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 130, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 131, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 132, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 133, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 134, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 135, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 136, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 137, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 138, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 139, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 140, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 141, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 142, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 143, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 144, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 145, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 146, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 147, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 148, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 149, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 150, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 151, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 152, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 153, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 154, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 155, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 156, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 157, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 158, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 159, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 160, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 161, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 162, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 163, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 164, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 165, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 166, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 167, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 168, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 169, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 170, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 171, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 172, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 173, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 174, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 175, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 176, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 177, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 178, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 179, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 180, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 181, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 182, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 183, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 184, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 185, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 186, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 187, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 188, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 189, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 190, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 191, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 192, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 193, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 194, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 195, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 196, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 197, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 198, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 199, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 200, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 201, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 202, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 203, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 204, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 205, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 206, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 207, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 208, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 209, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 210, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 211, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 212, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 213, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 214, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 215, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 216, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 217, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 218, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 219, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 220, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 221, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 222, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 223, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 224, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 225, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 226, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 227, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 228, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 229, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 230, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 231, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 232, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 233, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 234, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 235, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 236, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 237, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 238, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 239, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 240, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 241, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 242, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 243, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 244, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 245, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 246, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 247, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 248, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 249, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 250, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 251, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 252, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 253, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 254, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 255, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 256, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 257, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 258, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 259, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 260, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 261, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 262, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 263, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 264, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 265, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 266, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 267, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 268, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 269, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 270, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 271, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 272, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 273, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 274, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 275, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 276, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 277, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 278, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 279, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 280, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 281, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 282, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 283, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 284, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 285, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 286, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 287, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 288, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 289, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 290, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 291, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 292, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 293, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 294, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 295, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 296, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 297, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 298, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 299, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 300, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 301, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 302, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 303, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 304, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 305, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 306, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 307, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 308, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 309, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 310, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 311, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 312, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 313, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 314, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 315, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 316, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 317, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 318, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 319, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 320, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 321, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 322, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 323, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 324, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 325, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 326, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 327, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 328, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 329, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 330, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 331, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 332, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 333, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 334, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 335, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 336, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 337, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 338, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 339, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 340, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 341, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 342, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 343, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 344, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 345, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 346, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 347, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 348, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 349, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 350, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 351, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 352, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 353, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 354, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 355, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 356, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 357, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 358, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 359, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 360, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 361, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 362, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 363, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 364, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 365, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 366, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 367, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 368, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 369, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 370, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 371, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 372, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 373, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 374, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 375, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 376, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 377, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 378, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 379, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 380, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 381, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 382, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 383, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 384, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 385, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 386, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 387, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 388, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 389, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 390, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 391, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 392, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 393, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 394, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 395, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 396, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 397, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 398, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 399, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 400, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 401, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 402, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 403, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 404, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 405, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 406, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 407, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 408, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 409, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 410, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 411, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 412, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 413, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 414, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 415, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 416, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 417, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 418, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 419, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 420, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 421, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 422, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 423, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 424, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 425, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 426, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 427, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 428, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 429, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 430, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 431, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 432, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 433, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 434, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 435, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 436, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 437, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 438, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 439, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 440, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 441, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 442, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 443, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 444, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 445, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 446, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 447, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 448, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 449, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}
{"episode_index": 450, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 4360}
{"episode_index": 451, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4752}
{"episode_index": 452, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 3540}
{"episode_index": 453, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 4042}
{"episode_index": 454, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 3644}
{"episode_index": 455, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 3540}
{"episode_index": 456, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3208}
{"episode_index": 457, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4652}
{"episode_index": 458, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3704}
{"episode_index": 459, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5138}
{"episode_index": 460, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4698}
{"episode_index": 461, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3960}
{"episode_index": 462, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 4612}
{"episode_index": 463, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3940}
{"episode_index": 464, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4070}
{"episode_index": 465, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4482}
{"episode_index": 466, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 4408}
{"episode_index": 467, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4360}
{"episode_index": 468, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5304}
{"episode_index": 469, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4552}
{"episode_index": 470, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 3380}
{"episode_index": 471, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4314}
{"episode_index": 472, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4406}
{"episode_index": 473, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 3662}
{"episode_index": 474, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5238}
{"episode_index": 475, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 4534}
{"episode_index": 476, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 4906}
{"episode_index": 477, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3910}
{"episode_index": 478, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4668}
{"episode_index": 479, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 3792}
{"episode_index": 480, "tasks": ["With the left gripper, grasp the middle portion of the test tube and lift it away from the test tube rack. Move the test tube to the heated water-filled beaker and align it with the center of the beaker. Place the test tube into the water bath without allowing it to contact the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid level below the beaker water level. Wait until the reaction produces brick-red cuprous oxide. Pick up the test tube from the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4024}
{"episode_index": 481, "tasks": ["Grasp the test tube with the left robotic arm, lift it completely clear of the test tube rack, and move it toward the center of the heated water bath. Align the test tube with the center of the water-filled beaker and lower it into the water while preventing contact with the beaker wall and bottom. The test tube opening must remain above the beaker water surface, and the liquid level inside the test tube must remain below the beaker water level. Wait until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 5156}
{"episode_index": 482, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle section. Pick up the test tube from the rack and align it with the central region of the water-filled beaker. Place the test tube in the heated water bath without allowing the test tube to touch the beaker wall or bottom. Maintain the test tube with its opening above the water surface and its internal liquid surface below the water level in the beaker. Wait until the solution becomes brick red due to the formation of cuprous oxide. Then pick up the test tube from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3508}
{"episode_index": 483, "tasks": ["Grasp the test tube with the left gripper, lift it from the test tube rack, and move it to the heated water-filled beaker. Align the test tube with the center of the beaker before lowering it into the water bath. Place the test tube so that it does not touch the beaker wall or bottom, with the test tube opening above the beaker water surface and the liquid level inside the test tube below the beaker water level. Wait for brick-red cuprous oxide to form in the reaction mixture. After the brick-red precipitate forms, lift the test tube out of the water bath, return it toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3928}
{"episode_index": 484, "tasks": ["Using the left robotic arm, grasp the middle region of the test tube containing Fehling's reagent and standard sugar solution. Lift the test tube from the rack and align it with the central region of the heated water-filled beaker. Lower the test tube into the water bath without allowing it to contact the beaker wall or bottom. Ensure that the opening of the test tube remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms. Then lift the test tube from the water bath, move it back to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4776}
{"episode_index": 485, "tasks": ["Use the left gripper to grasp the test tube, pick it up from the test tube rack, and move it above the center of the heated water-filled beaker. Align the test tube with the center of the beaker and lower it into the water bath. Do not allow the test tube to contact the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water level in the beaker. Wait until brick-red cuprous oxide is produced. Then pick up the test tube, remove it from the water bath, move it to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3898}
{"episode_index": 486, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution using the left robotic arm, lift it away from the test tube rack, and move it toward the heated water-filled beaker. Align the test tube with the central region of the beaker and place it into the water bath without contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid level inside the test tube below the water surface. Maintain this position until a brick-red cuprous oxide precipitate forms. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the appropriate rack position, and insert it into the rack."], "length": 5654}
{"episode_index": 487, "tasks": ["Using the left robotic arm, grasp the middle portion of the test tube, lift it from the test tube rack, and align it with the center of the heated water bath. Lower the test tube into the water-filled beaker while ensuring that the test tube does not touch the beaker wall or bottom. Position the test tube so that the opening remains above the beaker water surface and the liquid inside the test tube remains below the beaker water level. Wait until brick-red cuprous oxide forms as the reaction proceeds. Then lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 3720}
{"episode_index": 488, "tasks": ["Use the left gripper to grasp the test tube containing Fehling's reagent and standard sugar solution at its middle region. Lift the test tube from the test tube rack, align it with the central region of the heated water-filled beaker, and lower it into the water bath without touching the beaker wall or bottom. Keep the test tube opening above the water surface while keeping the liquid level inside the test tube below the surrounding water level. Wait until a brick-red cuprous oxide precipitate is formed. Then grasp and lift the test tube from the water bath, move it toward the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 4364}
{"episode_index": 489, "tasks": ["Grasp the test tube containing Fehling's reagent and the standard sugar solution with the left robotic arm at its middle region. Lift the test tube so that it is completely separated from the test tube rack, move it to the center of the heated water-filled beaker, and align it with the center of the water bath. Lower the test tube into the water bath without allowing contact with the beaker wall or bottom. Ensure that the liquid level inside the test tube is below the water level in the beaker and that the test tube opening remains above the beaker water surface. Maintain the test tube in this position until brick-red cuprous oxide forms. After the reaction produces the brick-red precipitate, lift the test tube out of the water bath, move it back to the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4436}
{"episode_index": 490, "tasks": ["Move the test tube containing Fehling's reagent and the standard sugar solution from the test tube rack into the heated water bath, wait until a brick-red cuprous oxide precipitate forms, and return the test tube to the test tube rack."], "length": 5512}
{"episode_index": 491, "tasks": ["Use the robotic arm to grasp the test tube containing Fehling's reagent and the standard sugar solution, lift it from the test tube rack, place it in the heated water bath, wait until the solution becomes brick red, then remove the test tube and insert it back into the test tube rack."], "length": 4606}
{"episode_index": 492, "tasks": ["Use the left robotic arm to grasp the test tube, lift it clear of the test tube rack, align it with the center of the water-filled beaker, lower it into the heated water bath without touching the beaker wall or bottom, wait until brick-red cuprous oxide forms, then lift the test tube out and return it to the test tube rack."], "length": 4888}
{"episode_index": 493, "tasks": ["Grasp the test tube containing Fehling's reagent and standard sugar solution with the left gripper, pick it up from the test tube rack, align it with the central region of the heated water bath, place it in the water without touching the beaker wall or bottom, wait for the formation of brick-red cuprous oxide, then pick it up from the water bath and insert it into the test tube rack."], "length": 5724}
{"episode_index": 494, "tasks": ["Use the left gripper to grasp the middle region of the test tube, lift the test tube from the rack, move it to the center of the water-filled beaker, and lower it into the heated water bath while keeping the test tube away from the beaker wall and bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide forms, then remove the test tube from the water bath and insert it back into the test tube rack."], "length": 5646}
{"episode_index": 495, "tasks": ["Grasp the test tube with the left robotic arm and lift it from the test tube rack. Move the test tube above the center of the heated water-filled beaker, align it with the center of the water bath, and place it into the water without allowing contact with the beaker wall or bottom. Keep the test tube opening above the beaker water surface and the liquid inside the test tube below the beaker water level. Wait until the reaction produces brick-red cuprous oxide, then lift the test tube out of the water bath, align it with the test tube rack, and insert it into the rack."], "length": 5614}
{"episode_index": 496, "tasks": ["Using the left robotic arm, grasp the test tube containing Fehling's reagent and the standard sugar solution at its middle region. Lift it completely away from the test tube rack, align it with the central region of the heated water bath, and lower it into the water-filled beaker without touching the beaker wall or bottom. Ensure that the test tube opening remains above the water surface and that the liquid level inside the test tube remains below the water level in the beaker. Wait until brick-red cuprous oxide forms, then grasp and lift the test tube out of the water bath, move it back to the test tube rack, align it with an appropriate rack position, and insert it into the rack."], "length": 3688}
{"episode_index": 497, "tasks": ["Use the left robotic arm to grasp the test tube containing the Fehling reaction mixture, pick it up from the test tube rack, and move it toward the heated beaker. Align the test tube with the center of the beaker and place it into the water bath without contact between the test tube and the beaker wall or bottom. Position the test tube so that its opening is above the water surface and the liquid level inside the test tube is below the surrounding water level. Maintain this position until a brick-red cuprous oxide precipitate forms. Then pick up the test tube, remove it completely from the water bath, move it to the test tube rack, align it with the rack opening, and insert it into the rack."], "length": 3510}
{"episode_index": 498, "tasks": ["Grasp the test tube using the left gripper, lift it vertically from the test tube rack, and align the test tube with the central area of the heated water-filled beaker. Lower the test tube into the water bath while preventing contact with both the beaker wall and the beaker bottom. Keep the test tube opening above the beaker water surface and keep the liquid level inside the test tube below the beaker water level. Wait for the formation of brick-red cuprous oxide. After the color change occurs, lift the test tube out of the water bath, move it back toward the test tube rack, align it with the rack position, and insert it into the rack."], "length": 4904}
{"episode_index": 499, "tasks": ["Use the left robotic arm to grasp the test tube containing Fehling's reagent and standard sugar solution, lift it from the test tube rack, and position it above the center of the heated water-filled beaker. Align the test tube with the center of the water bath and lower it until the test tube is immersed without touching the beaker wall or bottom. Keep the test tube opening above the water surface and the liquid level inside the test tube below the water surface. Wait until brick-red cuprous oxide is generated. Then lift the test tube out of the heated water bath, move it to the test tube rack, align it with the corresponding rack position, and insert it into the rack."], "length": 5832}