File size: 335,598 Bytes
bbf9732 4a105bf bbf9732 d1292d8 bbf9732 4a105bf bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 4a105bf bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 4a105bf bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 4a105bf bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 4a105bf bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 4a105bf bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 d1292d8 bbf9732 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810 811 812 813 814 815 816 817 818 819 820 821 822 823 824 825 826 827 828 829 830 831 832 833 834 835 836 837 838 839 840 841 842 843 844 845 846 847 848 849 850 851 852 853 854 855 856 857 858 859 860 861 862 863 864 865 866 867 868 869 870 871 872 873 874 875 876 877 878 879 880 881 882 883 884 885 886 887 888 889 890 891 892 893 894 895 896 897 898 899 900 901 902 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941 942 943 944 945 946 947 948 949 950 951 952 953 954 955 956 957 958 959 960 961 962 963 964 965 966 967 968 969 970 971 972 973 974 975 976 977 978 979 980 981 982 983 984 985 986 987 988 989 990 991 992 993 994 995 996 997 998 999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113 1114 1115 1116 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1139 1140 1141 1142 1143 1144 1145 1146 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1168 1169 1170 1171 1172 1173 1174 1175 1176 1177 1178 1179 1180 1181 1182 1183 1184 1185 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 1199 1200 1201 1202 1203 1204 1205 1206 1207 1208 1209 1210 1211 1212 1213 1214 1215 1216 1217 1218 1219 1220 1221 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232 1233 1234 1235 1236 1237 1238 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1257 1258 1259 1260 1261 1262 1263 1264 1265 1266 1267 1268 1269 1270 1271 1272 1273 1274 1275 1276 1277 1278 1279 1280 1281 1282 1283 1284 1285 1286 1287 1288 1289 1290 1291 1292 1293 1294 1295 1296 1297 1298 1299 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347 1348 1349 1350 1351 1352 1353 1354 1355 1356 1357 1358 1359 1360 1361 1362 1363 1364 1365 1366 1367 1368 1369 1370 1371 1372 1373 1374 1375 1376 1377 1378 1379 1380 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 1392 1393 1394 1395 1396 1397 1398 1399 1400 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1419 1420 1421 1422 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 1438 1439 1440 1441 1442 1443 1444 1445 1446 1447 1448 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1461 1462 1463 1464 1465 1466 1467 1468 1469 1470 1471 1472 1473 1474 1475 1476 1477 1478 1479 1480 1481 1482 1483 1484 1485 1486 1487 1488 1489 1490 1491 1492 1493 1494 1495 1496 1497 1498 1499 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1539 1540 1541 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1598 1599 1600 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 1660 1661 1662 1663 1664 1665 1666 1667 1668 1669 1670 1671 1672 1673 1674 1675 1676 1677 1678 1679 1680 1681 1682 1683 1684 1685 1686 1687 1688 1689 1690 1691 1692 1693 1694 1695 1696 1697 1698 1699 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1714 1715 1716 1717 1718 1719 1720 1721 1722 1723 1724 1725 1726 1727 1728 1729 1730 1731 1732 1733 1734 1735 1736 1737 1738 1739 1740 1741 1742 1743 1744 1745 1746 1747 1748 1749 1750 1751 1752 1753 1754 1755 1756 1757 1758 1759 1760 1761 1762 1763 1764 1765 1766 1767 1768 1769 1770 1771 1772 1773 1774 1775 1776 1777 1778 1779 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 1799 1800 1801 1802 1803 1804 1805 1806 1807 1808 1809 1810 1811 1812 1813 1814 1815 1816 1817 1818 1819 1820 1821 1822 1823 1824 1825 1826 1827 1828 1829 1830 1831 1832 1833 1834 1835 1836 1837 1838 1839 1840 1841 1842 1843 1844 1845 1846 1847 1848 1849 1850 1851 1852 1853 1854 1855 1856 1857 1858 1859 1860 1861 1862 1863 1864 1865 1866 1867 1868 1869 1870 1871 1872 1873 1874 1875 1876 1877 1878 1879 1880 1881 1882 1883 1884 1885 1886 1887 1888 1889 1890 1891 1892 1893 1894 1895 1896 1897 1898 1899 1900 1901 1902 1903 1904 1905 1906 1907 1908 1909 1910 1911 1912 1913 1914 1915 1916 1917 1918 1919 1920 1921 1922 1923 1924 1925 1926 1927 1928 1929 1930 1931 1932 1933 1934 1935 1936 1937 1938 1939 1940 1941 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961 1962 1963 1964 1965 1966 1967 1968 1969 1970 1971 1972 1973 1974 1975 1976 1977 1978 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072 2073 2074 2075 2076 2077 2078 2079 2080 2081 2082 2083 2084 2085 2086 2087 2088 2089 2090 2091 2092 2093 2094 2095 2096 2097 2098 2099 2100 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2121 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 2135 2136 2137 2138 2139 2140 2141 2142 2143 2144 2145 2146 2147 2148 2149 2150 2151 2152 2153 2154 2155 2156 2157 2158 2159 2160 2161 2162 2163 2164 2165 2166 2167 2168 2169 2170 2171 2172 2173 2174 2175 2176 2177 2178 2179 2180 2181 2182 2183 2184 2185 2186 2187 2188 2189 2190 2191 2192 2193 2194 2195 2196 2197 2198 2199 2200 2201 2202 2203 2204 2205 2206 2207 2208 2209 2210 2211 2212 2213 2214 2215 2216 2217 2218 2219 2220 2221 2222 2223 2224 2225 2226 2227 2228 2229 2230 2231 2232 2233 2234 2235 2236 2237 2238 2239 2240 2241 2242 2243 2244 2245 2246 2247 2248 2249 2250 2251 2252 2253 2254 2255 2256 2257 2258 2259 2260 2261 2262 2263 2264 2265 2266 2267 2268 2269 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 2280 2281 2282 2283 2284 2285 2286 2287 2288 2289 2290 2291 2292 2293 2294 2295 2296 2297 2298 2299 2300 2301 2302 2303 2304 2305 2306 2307 2308 2309 2310 2311 2312 2313 2314 2315 2316 2317 2318 2319 2320 2321 2322 2323 2324 2325 2326 2327 2328 2329 2330 2331 2332 2333 2334 2335 2336 2337 2338 2339 2340 2341 2342 2343 2344 2345 2346 2347 2348 2349 2350 2351 2352 2353 2354 2355 2356 2357 2358 2359 2360 2361 2362 2363 2364 2365 2366 2367 2368 2369 2370 2371 2372 2373 2374 2375 2376 2377 2378 2379 2380 2381 2382 2383 2384 2385 2386 2387 2388 2389 2390 2391 2392 2393 2394 2395 2396 2397 2398 2399 2400 2401 2402 2403 2404 2405 2406 2407 2408 2409 2410 2411 2412 2413 2414 2415 2416 2417 2418 2419 2420 2421 2422 2423 2424 2425 2426 2427 2428 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 2455 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 2481 2482 2483 2484 2485 2486 2487 2488 2489 2490 2491 2492 2493 2494 2495 2496 2497 2498 2499 2500 2501 2502 2503 2504 2505 2506 2507 2508 2509 2510 2511 2512 2513 2514 2515 2516 2517 2518 2519 2520 2521 2522 2523 2524 2525 2526 2527 2528 2529 2530 2531 2532 2533 2534 2535 2536 2537 2538 2539 2540 2541 2542 2543 2544 2545 2546 2547 2548 2549 2550 2551 2552 2553 2554 2555 2556 2557 2558 2559 2560 2561 2562 2563 2564 2565 2566 2567 2568 2569 2570 2571 2572 2573 2574 2575 2576 2577 2578 2579 2580 2581 2582 2583 2584 2585 2586 2587 2588 2589 2590 2591 2592 2593 2594 2595 2596 2597 2598 2599 2600 2601 2602 2603 2604 2605 2606 2607 2608 2609 2610 2611 2612 2613 2614 2615 2616 2617 2618 2619 2620 2621 2622 2623 2624 2625 2626 2627 2628 2629 2630 2631 2632 2633 2634 2635 2636 2637 2638 2639 2640 2641 2642 2643 2644 2645 2646 2647 2648 2649 2650 2651 2652 2653 2654 2655 2656 2657 2658 2659 2660 2661 2662 2663 2664 2665 2666 2667 2668 2669 2670 2671 2672 2673 2674 2675 2676 2677 2678 2679 2680 2681 2682 2683 2684 2685 2686 2687 2688 2689 2690 2691 2692 2693 2694 2695 2696 2697 2698 2699 2700 2701 2702 2703 2704 2705 2706 2707 2708 2709 2710 2711 2712 2713 2714 2715 2716 2717 2718 2719 2720 2721 2722 2723 2724 2725 2726 2727 2728 2729 2730 2731 2732 2733 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2757 2758 2759 2760 2761 2762 2763 2764 2765 2766 2767 2768 2769 2770 2771 2772 2773 2774 2775 2776 2777 2778 2779 2780 2781 2782 2783 2784 2785 2786 2787 2788 2789 2790 2791 2792 2793 2794 2795 2796 2797 2798 2799 2800 2801 2802 2803 2804 2805 2806 2807 2808 2809 2810 2811 2812 2813 2814 2815 2816 2817 2818 2819 2820 2821 2822 2823 2824 2825 2826 2827 2828 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 2840 2841 2842 2843 2844 2845 2846 2847 2848 2849 2850 2851 2852 2853 2854 2855 2856 2857 2858 2859 2860 2861 2862 2863 2864 2865 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2876 2877 2878 2879 2880 2881 2882 2883 2884 2885 2886 2887 2888 2889 2890 2891 2892 2893 2894 2895 2896 2897 2898 2899 2900 2901 2902 2903 2904 2905 2906 2907 2908 2909 2910 2911 2912 2913 2914 2915 2916 2917 2918 2919 2920 2921 2922 2923 2924 2925 2926 2927 2928 2929 2930 2931 2932 2933 2934 2935 2936 2937 2938 2939 2940 2941 2942 2943 2944 2945 2946 2947 2948 2949 2950 2951 2952 2953 2954 2955 2956 2957 2958 2959 2960 2961 2962 2963 2964 2965 2966 2967 2968 2969 2970 2971 2972 2973 2974 2975 2976 2977 2978 2979 2980 2981 2982 2983 2984 2985 2986 2987 2988 2989 2990 2991 2992 2993 2994 2995 2996 2997 2998 2999 3000 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3013 3014 3015 3016 3017 3018 3019 3020 3021 3022 3023 3024 3025 3026 3027 3028 3029 3030 3031 3032 3033 3034 3035 3036 3037 3038 3039 3040 3041 3042 3043 3044 3045 3046 3047 3048 3049 3050 3051 3052 3053 3054 3055 3056 3057 3058 3059 3060 3061 3062 3063 3064 3065 3066 3067 3068 3069 3070 3071 3072 3073 3074 3075 3076 3077 3078 3079 3080 3081 3082 3083 3084 3085 3086 3087 3088 3089 3090 3091 3092 3093 3094 3095 3096 3097 3098 3099 3100 3101 3102 3103 3104 3105 3106 3107 3108 3109 3110 3111 3112 3113 3114 3115 3116 3117 3118 3119 3120 3121 3122 3123 3124 3125 3126 3127 3128 3129 3130 3131 3132 3133 3134 3135 3136 3137 3138 3139 3140 3141 3142 3143 3144 3145 3146 3147 3148 3149 3150 3151 3152 3153 3154 3155 3156 3157 3158 3159 3160 3161 3162 3163 3164 3165 3166 3167 3168 3169 3170 3171 3172 3173 3174 3175 3176 3177 3178 3179 3180 3181 3182 3183 3184 3185 3186 3187 3188 3189 3190 3191 3192 3193 3194 3195 3196 3197 3198 3199 3200 3201 3202 3203 3204 3205 3206 3207 3208 3209 3210 3211 3212 3213 3214 3215 3216 3217 3218 3219 3220 3221 3222 3223 3224 3225 3226 3227 3228 3229 3230 3231 3232 3233 3234 3235 3236 3237 3238 3239 3240 3241 3242 3243 3244 3245 3246 3247 3248 3249 3250 3251 3252 3253 3254 3255 3256 3257 3258 3259 3260 3261 3262 3263 3264 3265 3266 3267 3268 3269 3270 3271 3272 3273 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 3285 3286 3287 3288 3289 3290 3291 3292 3293 3294 3295 3296 3297 3298 3299 3300 3301 3302 3303 3304 3305 3306 3307 3308 3309 3310 3311 3312 3313 3314 3315 3316 3317 3318 3319 3320 3321 3322 3323 3324 3325 3326 3327 3328 3329 3330 3331 3332 3333 3334 3335 3336 3337 3338 3339 3340 3341 3342 3343 3344 3345 3346 3347 3348 3349 3350 3351 3352 3353 3354 3355 3356 3357 3358 3359 3360 3361 3362 3363 3364 3365 3366 3367 3368 3369 3370 3371 3372 3373 3374 3375 3376 3377 3378 3379 3380 3381 3382 3383 3384 3385 3386 3387 3388 3389 3390 3391 3392 3393 3394 3395 3396 3397 3398 3399 3400 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3422 3423 3424 3425 3426 3427 3428 3429 3430 3431 3432 3433 3434 3435 3436 3437 3438 3439 3440 3441 3442 3443 3444 3445 3446 3447 3448 3449 3450 3451 3452 3453 3454 3455 3456 3457 3458 3459 3460 3461 3462 3463 3464 3465 3466 3467 3468 3469 3470 3471 3472 3473 3474 3475 3476 3477 3478 3479 3480 3481 3482 3483 3484 3485 3486 3487 3488 3489 3490 3491 3492 3493 3494 3495 3496 3497 3498 3499 3500 3501 3502 3503 3504 3505 3506 3507 3508 3509 3510 3511 3512 3513 3514 3515 3516 3517 3518 3519 3520 3521 3522 3523 3524 3525 3526 3527 3528 3529 3530 3531 3532 3533 3534 3535 3536 3537 3538 3539 3540 3541 3542 3543 3544 3545 3546 3547 3548 3549 3550 3551 3552 3553 3554 3555 3556 3557 3558 3559 3560 3561 3562 3563 3564 3565 3566 3567 3568 3569 3570 3571 3572 3573 3574 3575 3576 3577 3578 3579 3580 3581 3582 3583 3584 3585 3586 3587 3588 3589 3590 3591 3592 3593 3594 3595 3596 3597 3598 3599 3600 3601 3602 3603 3604 3605 3606 3607 3608 3609 3610 3611 3612 3613 3614 3615 3616 3617 3618 3619 3620 3621 3622 3623 3624 3625 3626 3627 3628 3629 3630 3631 3632 3633 3634 3635 3636 3637 3638 3639 3640 3641 3642 3643 3644 3645 3646 3647 3648 3649 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3660 3661 3662 3663 3664 3665 3666 3667 3668 3669 3670 3671 3672 3673 3674 3675 3676 3677 3678 3679 3680 3681 3682 3683 3684 3685 3686 3687 3688 3689 3690 3691 3692 3693 3694 3695 3696 3697 3698 3699 3700 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 3719 3720 3721 3722 3723 3724 3725 3726 3727 3728 3729 3730 3731 3732 3733 3734 3735 3736 3737 3738 3739 3740 3741 3742 3743 3744 3745 3746 3747 3748 3749 3750 3751 3752 3753 3754 3755 3756 3757 3758 3759 3760 3761 3762 3763 3764 3765 3766 3767 3768 3769 3770 3771 3772 3773 3774 3775 3776 3777 3778 3779 3780 3781 3782 3783 3784 3785 3786 3787 3788 3789 3790 3791 3792 3793 3794 3795 3796 3797 3798 3799 3800 3801 3802 3803 3804 3805 3806 3807 3808 3809 3810 3811 3812 3813 3814 3815 3816 3817 3818 3819 3820 3821 3822 3823 3824 3825 3826 3827 3828 3829 3830 3831 3832 3833 3834 3835 3836 3837 3838 3839 3840 3841 3842 3843 3844 3845 3846 3847 3848 3849 3850 3851 3852 3853 3854 3855 3856 3857 3858 3859 3860 3861 3862 3863 3864 3865 3866 3867 3868 3869 3870 3871 3872 3873 3874 3875 3876 3877 3878 3879 3880 3881 3882 3883 3884 3885 3886 3887 3888 3889 3890 3891 3892 3893 3894 3895 3896 3897 3898 3899 3900 3901 3902 3903 3904 3905 3906 3907 3908 3909 3910 3911 3912 3913 3914 3915 3916 3917 3918 3919 3920 3921 3922 3923 3924 3925 3926 3927 3928 3929 3930 3931 3932 3933 3934 3935 3936 3937 3938 3939 3940 3941 3942 3943 3944 3945 3946 3947 3948 3949 3950 3951 3952 3953 3954 3955 3956 3957 3958 3959 3960 3961 3962 3963 3964 3965 3966 3967 3968 3969 3970 3971 3972 3973 3974 3975 3976 3977 3978 3979 3980 3981 3982 3983 3984 3985 3986 3987 3988 3989 3990 3991 3992 3993 3994 3995 3996 3997 3998 3999 4000 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4028 4029 4030 4031 4032 4033 4034 4035 4036 4037 4038 4039 4040 4041 4042 4043 4044 4045 4046 4047 4048 4049 4050 4051 4052 4053 4054 4055 4056 4057 4058 4059 4060 4061 4062 4063 4064 4065 4066 4067 4068 4069 4070 4071 4072 4073 4074 4075 4076 4077 4078 4079 4080 4081 4082 4083 4084 4085 4086 4087 4088 4089 4090 4091 4092 4093 4094 4095 4096 4097 4098 4099 4100 4101 4102 4103 4104 4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121 4122 4123 4124 4125 4126 4127 4128 4129 4130 4131 4132 4133 4134 4135 4136 4137 4138 4139 4140 4141 4142 4143 4144 4145 4146 4147 4148 4149 4150 4151 4152 4153 4154 4155 4156 4157 4158 4159 4160 4161 4162 4163 4164 4165 4166 4167 4168 4169 4170 4171 4172 4173 4174 4175 4176 4177 4178 4179 4180 4181 4182 4183 4184 4185 4186 4187 4188 4189 4190 4191 4192 4193 4194 4195 4196 4197 4198 4199 4200 4201 4202 4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213 4214 4215 4216 4217 4218 4219 4220 4221 4222 4223 4224 4225 4226 4227 4228 4229 4230 4231 4232 4233 4234 4235 4236 4237 4238 4239 4240 4241 4242 4243 4244 4245 4246 4247 4248 4249 4250 4251 4252 4253 4254 4255 4256 4257 4258 4259 4260 4261 4262 4263 4264 4265 4266 4267 4268 4269 4270 4271 4272 4273 4274 4275 4276 4277 4278 4279 4280 4281 4282 4283 4284 4285 4286 4287 4288 4289 4290 4291 4292 4293 4294 4295 4296 4297 4298 4299 4300 4301 4302 4303 4304 4305 4306 4307 4308 4309 4310 4311 4312 4313 4314 4315 4316 4317 4318 4319 4320 4321 4322 4323 4324 4325 4326 4327 4328 4329 4330 4331 4332 4333 4334 4335 4336 4337 4338 4339 4340 4341 4342 4343 4344 4345 4346 4347 4348 4349 4350 4351 4352 4353 4354 4355 4356 4357 4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369 4370 4371 4372 4373 4374 4375 4376 4377 4378 4379 4380 4381 4382 4383 4384 4385 4386 4387 4388 4389 4390 4391 4392 4393 4394 4395 4396 4397 4398 4399 4400 4401 4402 4403 4404 4405 4406 4407 4408 4409 4410 4411 4412 4413 4414 4415 4416 4417 4418 4419 4420 4421 4422 4423 4424 4425 4426 4427 4428 4429 4430 4431 4432 4433 4434 4435 4436 4437 4438 4439 4440 4441 4442 4443 4444 4445 4446 | """Append-only measurement runtimes. CHEM-001 uses synthetic PX224E-family behavior.
The XPR204E catalogue target and the reused OHAUS geometry are distinct. The
filtered runtime is an engineering model, not either manufacturer's firmware.
Only the trusted host supplies supported pan force and advances the common clock.
Session filtering is an API boundary, not a Python or filesystem sandbox.
"""
import copy as _xpr_copy
import hashlib as _xpr_hashlib
import json as _xpr_json
import math as _xpr_math
import random as _xpr_random
import threading as _xpr_threading
from collections import deque as _xpr_deque
from decimal import Decimal as _xpr_Decimal, ROUND_HALF_UP as _xpr_ROUND_HALF_UP
from datetime import datetime as _xpr_datetime, timezone as _xpr_timezone
from pathlib import Path as _xpr_Path
try:
from .balance_runtime import Balance as _XPRLegacyBalance
except ImportError:
from balance_runtime import Balance as _XPRLegacyBalance
XPR204E_TYPE = "instrument.mt_xpr204e"
XPR204E_CAPACITY_KG = 0.220
XPR204E_READABILITY_KG = 1e-7
XPR204E_TARGET_SETTLING_S = 1.5
XPR204E_DOOR_MAX_M = 0.109
XPR204E_CALIBRATION_MIN_KG = 1e-12 # Numerical input envelope, not a vendor standard-mass specification.
XPR204E_FILTERS = {
"Low": {"time_constant_s": 0.25, "stability_divisions": 512},
"Medium": {"time_constant_s": 1.0, "stability_divisions": 256},
"High": {"time_constant_s": 4.0, "stability_divisions": 128},
}
XPR204E_SCENE_KEYS = (
"power.enabled", "balance.filter_level", "balance.display_unit", "balance.status", "balance.stable",
"balance.gross_kg", "balance.net_kg", "balance.tare_kg", "balance.calibrated", "balance.task_ready",
"balance.synthetic", "balance.stability_elapsed_s", "pan.installed", "environment.tilt_rad", "environment.vibration",
"door.left.opening_m", "door.right.opening_m", "door.top.opening_m",
)
def _xpr_number(value):
try:
return type(value) in (int, float) and _xpr_math.isfinite(value)
except (TypeError, OverflowError):
return False
def _xpr_num_schema(unit, minimum=None, maximum=None, nullable=False):
spec = {"type": "number", "x-unit": unit}
if minimum is not None:
spec["minimum"] = minimum
if maximum is not None:
spec["maximum"] = maximum
return {"anyOf": [spec, {"type": "null"}]} if nullable else spec
def _xpr_object(properties):
return {"type": "object", "properties": properties, "required": list(properties), "additionalProperties": False}
def _xpr_quantize(value):
step = _xpr_Decimal(str(XPR204E_READABILITY_KG))
return float((_xpr_Decimal(str(value)) / step).quantize(_xpr_Decimal("1"), rounding=_xpr_ROUND_HALF_UP) * step)
class FilteredAnalyticalBalance(_XPRLegacyBalance):
"""Trusted force-input core. Direct read() is a debugging interface.
The manufacturer's Low/Medium/High ordering is documented in PX manual
section 5.3.3. All numeric tau/N values and the five-tau startup interval are
engineering assumptions for the specified white-contact-noise experiment.
N is a full peak-to-peak displayed range, NOT accuracy or repeatability.
The 1.5 s default holding window is the XPR catalogue target reused as a
simulation rule; it is not proof of a 1.5 s instrument response.
"""
def __init__(self, *, filter_level="Medium", settling_s=XPR204E_TARGET_SETTLING_S):
if not isinstance(filter_level, str) or filter_level not in XPR204E_FILTERS or not _xpr_number(settling_s) or not 0 < settling_s <= 60:
raise ValueError("Unknown filter or invalid finite settling interval")
super().__init__(XPR204E_CAPACITY_KG, XPR204E_READABILITY_KG, float(settling_s), True)
self.filter_level = filter_level
self.raw_force_N = 0.0
self.filtered_force_N = None
self.sample_time_s = 0.0
self.filter_age_s = 0.0
self._stability_samples = _xpr_deque()
self._window_range_kg = None
@classmethod
def for_model(cls, model):
if model == "XPR204E":
return cls()
if model == "PX224E":
return cls(settling_s=3.0)
raise ValueError("This filtered analytical family supports XPR204E and PX224E")
def reset_stability(self, *, clear_filter=False):
self.stable = False
self.elapsed_s = 0.0
self.last_environment_valid = False
self._stability_samples.clear()
self._window_range_kg = None
if clear_filter:
self.filtered_force_N = None
self.filter_age_s = 0.0
@property
def stability_band_kg(self):
return XPR204E_FILTERS[self.filter_level]["stability_divisions"] * self.readability_kg
def set_power(self, enabled):
if type(enabled) is not bool:
raise ValueError("Power is boolean")
if self.powered != enabled:
self.powered = enabled
self.reset_stability(clear_filter=True)
def set_filter(self, level):
if not isinstance(level, str) or level not in XPR204E_FILTERS:
raise ValueError("Unknown filter level")
if self.security_locked:
raise ValueError("Filter configuration is locked")
if level != self.filter_level:
self.filter_level = level
self.reset_stability(clear_filter=True)
def update(self, pan_load_force_N, dt_s, *, door_fraction=0.0, tilt_rad=0.0, vibration=False):
if (not _xpr_number(pan_load_force_N) or not _xpr_number(dt_s) or dt_s < 0
or not _xpr_number(door_fraction) or not 0 <= door_fraction <= 1
or not _xpr_number(tilt_rad) or type(vibration) is not bool):
raise ValueError("Finite SI force/time/environment and boolean vibration required")
if dt_s == 0:
return self.read()
self.sample_time_s += dt_s
self.raw_force_N = float(pan_load_force_N)
self.door_fraction, self.tilt_rad = float(door_fraction), float(tilt_rad)
if self.filtered_force_N is None:
self.filtered_force_N = self.raw_force_N
else:
tau = XPR204E_FILTERS[self.filter_level]["time_constant_s"]
alpha = -_xpr_math.expm1(-dt_s / tau)
# Convex form avoids overflow when two finite forces have opposite signs.
self.filtered_force_N = (1 - alpha) * self.filtered_force_N + alpha * self.raw_force_N
self.filter_age_s += dt_s
self.gross_kg = self.filtered_force_N / self.g_cal
hardware = self.powered and self.pan_installed and self.pan_latched and self.transport_unlocked
environment = door_fraction <= 0.01 and abs(tilt_rad) <= _xpr_math.radians(0.2) and not vibration
# Raw force rejects overload immediately: smoothing must not conceal it.
# Near-zero negative noise is handled by the filtered lower bound, not
# by resetting on every negative raw sample. The N*d tolerance is an
# engineering assumption; displayed negative values are not clipped.
range_valid = self.raw_force_N / self.g_cal <= self.capacity_kg and -self.stability_band_kg <= self.gross_kg <= self.capacity_kg
valid = hardware and environment and range_valid
if not valid:
self.reset_stability()
return self.read()
displayed = _xpr_quantize(self.gross_kg)
samples = self._stability_samples
samples.append((self.sample_time_s, displayed))
cutoff = self.sample_time_s - self.settling_s
# Retain a bracketing sample so the verified window is never too short.
while len(samples) > 1 and samples[1][0] <= cutoff + 1e-10:
samples.popleft()
self._window_range_kg = max(v for _, v in samples) - min(v for _, v in samples)
band = self.stability_band_kg
inside = self._window_range_kg <= band + 1e-15
self.elapsed_s = min(self.settling_s, self.sample_time_s - samples[0][0]) if inside else 0.0
warmed = self.filter_age_s + 1e-10 >= 5 * XPR204E_FILTERS[self.filter_level]["time_constant_s"]
self.last_environment_valid = True
self.stable = bool(inside and warmed and self.elapsed_s + 1e-10 >= self.settling_s)
return self.read()
def read(self):
if not self.powered:
status = "OFF"
elif not self.pan_installed:
status = "PAN_REMOVED"
elif not self.pan_latched:
status = "PAN_UNLATCHED"
elif not self.transport_unlocked:
status = "TRANSPORT_LOCKED"
elif self.raw_force_N / self.g_cal > self.capacity_kg or self.gross_kg > self.capacity_kg:
status = "OVERLOAD"
elif self.gross_kg < -self.stability_band_kg:
status = "UNDERLOAD"
else:
status = "STABLE" if self.stable else "UNSTABLE"
observable = status in ("STABLE", "UNSTABLE") and self.filtered_force_N is not None
# Do not quantize unbounded overloads or invent a reading before acquisition.
net = _xpr_quantize(self.gross_kg - self.zero_kg - self.tare_kg) if observable else None
stable = status == "STABLE"
return {"status": status, "stable": stable, "net_kg": net,
"value": None if net is None else net * (1000 if self.unit == "g" else 1),
"unit": self.unit, "gross_kg": self.gross_kg, "tare_kg": self.tare_kg,
"calibrated": self.calibrated, "task_ready": stable and self.calibrated,
"synthetic": True, "filter_level": self.filter_level, "raw_force_N": self.raw_force_N,
"filtered_force_N": self.filtered_force_N, "stability_window_range_kg": self._window_range_kg}
def press(self, key, hold_s=0.1):
if not _xpr_number(hold_s) or hold_s < 0:
raise ValueError("Finite nonnegative hold time required")
if key == "zero" and (hold_s >= 2 or not self.powered):
self.set_power(hold_s < 2)
return self.read()
return super().press(key, hold_s)
def calibrate_span(self, known_mass_kg, measured_load_force_N):
"""Validate trusted direct calibration inputs before changing any state."""
if (not _xpr_number(known_mass_kg) or not XPR204E_CALIBRATION_MIN_KG <= known_mass_kg <= self.capacity_kg
or not _xpr_number(measured_load_force_N) or measured_load_force_N <= 0
or self.filtered_force_N is None):
raise ValueError("Finite calibration mass/force within the numeric input envelope required")
gain = measured_load_force_N / known_mass_kg
if not _xpr_number(gain) or gain <= 0 or not _xpr_number(self.filtered_force_N / gain):
raise ValueError("Calibration would produce a non-finite numerical state")
super().calibrate_span(known_mass_kg, measured_load_force_N)
self.gross_kg = self.filtered_force_N / self.g_cal
self.reset_stability()
def calibrate_known_mass(self, known_mass_kg):
if not _xpr_number(known_mass_kg) or not XPR204E_CALIBRATION_MIN_KG <= known_mass_kg <= self.capacity_kg:
raise ValueError("Known calibration mass is outside capacity")
if self.filtered_force_N is None or self.filtered_force_N <= 0:
raise ValueError("A positive stable calibration load is required")
self.calibrate_span(known_mass_kg, self.filtered_force_N)
def export_xpr204e_contract_metadata():
"""Contract authoring metadata only. No live sample force or private state."""
def slot(unit, origin, schema, visibility="agent", route=None):
return {"unit": unit, "origin": origin, "visibility": visibility,
"access": "read_write" if route else "read_only", "value_schema": schema,
"write_via": route, "read_binding": "XPR204ESession.read(instance_id=..., state_ids=[state_id])",
"sampling": {"mode": "instant", "time_domain": "simulation", "window": None},
"reference_conditions": None}
def route(cap, parameter, fixed=None):
return {"capability_id": cap, "parameter": parameter, "fixed_arguments": fixed or {}}
boolean = {"type": "boolean"}
statuses = {"type": "string", "enum": ["OFF", "PAN_REMOVED", "PAN_UNLATCHED", "TRANSPORT_LOCKED", "OVERLOAD", "UNDERLOAD", "UNSTABLE", "STABLE"]}
levels = {"type": "string", "enum": list(XPR204E_FILTERS)}
units = {"type": "string", "enum": ["kg", "g"]}
slots = {
"power.enabled": slot("1", "setpoint", boolean, route=route("power.set", "enabled")),
"balance.filter_level": slot("1", "setpoint", levels, route=route("balance.set_filter", "level")),
"balance.display_unit": slot("1", "setpoint", units, route=route("balance.set_display_unit", "unit")),
"balance.status": slot("1", "derived", statuses),
"balance.stable": slot("1", "derived", boolean),
"balance.gross_kg": slot("kg", "derived", _xpr_num_schema("kg", nullable=True)),
"balance.net_kg": slot("kg", "derived", _xpr_num_schema("kg", nullable=True)),
"balance.tare_kg": slot("kg", "derived", _xpr_num_schema("kg")),
"balance.calibrated": slot("1", "derived", boolean),
"balance.task_ready": slot("1", "derived", boolean),
"balance.synthetic": slot("1", "derived", {"type": "boolean", "const": True}),
"balance.raw_force_n": slot("N", "process_truth", _xpr_num_schema("N"), "debug"),
"balance.filtered_force_n": slot("N", "process_truth", _xpr_num_schema("N", nullable=True), "debug"),
"balance.gain_n_kg": slot("N/kg", "process_truth", _xpr_num_schema("N/kg", 0), "debug"),
"balance.zero_kg": slot("kg", "process_truth", _xpr_num_schema("kg"), "debug"),
"balance.stability_elapsed_s": slot("s", "derived", _xpr_num_schema("s", 0)),
"pan.installed": slot("1", "scene", boolean, route=route("scene.set_pan", "installed")),
"environment.tilt_rad": slot("rad", "scene", _xpr_num_schema("rad")),
"environment.vibration": slot("1", "scene", boolean),
}
for side in ("left", "right", "top"):
slots[f"door.{side}.opening_m"] = slot("m", "scene", _xpr_num_schema("m", 0, XPR204E_DOOR_MAX_M),
route=route("scene.set_door", "opening_m", {"side": side}))
reading = {"status": statuses, "stable": boolean, "gross_kg": _xpr_num_schema("kg", nullable=True),
"net_kg": _xpr_num_schema("kg", nullable=True), "synthetic": {"type": "boolean", "const": True}}
definitions = {
"power.set": ({"enabled": boolean}, {"enabled": boolean}, {"enabled": True}, "设置本机供电;电源变化清空滤波启动与稳定历史。", ["power.enabled", "balance.stable", "balance.status", "balance.stability_elapsed_s"], ["power.enabled"]),
"balance.set_filter": ({"level": levels}, {"level": levels}, {"level": "High"}, "选择三档合成低通模型,改变设置后重新暖机。", ["balance.filter_level", "balance.stable", "balance.status", "balance.stability_elapsed_s"], ["balance.filter_level"]),
"balance.tare": ({}, {"tare_kg": _xpr_num_schema("kg")}, {}, "稳定时去皮;以后显示净重,毛重用于超载判定。", ["balance.tare_kg", "balance.net_kg"], ["balance.tare_kg"]),
"balance.zero": ({}, {"zeroed": boolean}, {}, "稳定且在假设的整机量程2%零点捕获范围内归零,并清除去皮。", ["balance.zero_kg", "balance.tare_kg", "balance.net_kg"], ["balance.net_kg"]),
"balance.set_display_unit": ({"unit": units}, {"unit": units}, {"unit": "g"}, "选择面板单位标签;公共质量接口始终以kg输出。", ["balance.display_unit"], ["balance.display_unit"]),
"balance.calibrate_span": ({"known_mass_kg": _xpr_num_schema("kg", XPR204E_CALIBRATION_MIN_KG, XPR204E_CAPACITY_KG)}, {"calibrated": boolean, "synthetic": {"type": "boolean", "const": True}}, {"known_mass_kg": 0.1}, "以已知标准砝码和当前滤波载荷进行简化单点增益校准;非厂家自动校准过程。", ["balance.gain_n_kg", "balance.zero_kg", "balance.tare_kg", "balance.calibrated", "balance.gross_kg", "balance.net_kg", "balance.stable", "balance.status", "balance.stability_elapsed_s"], ["balance.calibrated", "balance.synthetic"]),
"balance.reading": ({}, reading, {}, "读取同版本的量化滤波毛重、净重和稳定状态,不推进时钟。", [], ["balance.status", "balance.stable", "balance.gross_kg", "balance.net_kg", "balance.synthetic"]),
"scene.set_door": ({"side": {"type": "string", "enum": ["left", "right", "top"]}, "opening_m": _xpr_num_schema("m", 0, XPR204E_DOOR_MAX_M)}, {"side": {"type": "string", "enum": ["left", "right", "top"]}, "opening_m": _xpr_num_schema("m")}, {"side": "left", "opening_m": 0.05}, "同步设置复用PX224E滑门的+Y平移;改变门位后重新稳定。", ["door.left.opening_m", "door.right.opening_m", "door.top.opening_m", "balance.stable", "balance.status", "balance.stability_elapsed_s"], ["door.left.opening_m", "door.right.opening_m", "door.top.opening_m"]),
"scene.set_pan": ({"installed": boolean}, {"installed": boolean}, {"installed": False}, "仅在断电卸载后切换秤盘装配槽;不模拟机器人拆装或自由体接触。", ["pan.installed", "balance.stable", "balance.status", "balance.stability_elapsed_s"], ["pan.installed"]),
}
caps = {}
for name, (inputs, outputs, example, description, effects, observes) in definitions.items():
if name in ("power.set", "balance.set_filter"):
effects += ["balance.filtered_force_n", "balance.gross_kg", "balance.net_kg", "balance.task_ready"]
if name in ("balance.calibrate_span", "scene.set_door", "scene.set_pan"):
effects += ["balance.task_ready"]
if name == "scene.set_pan":
effects += ["balance.gross_kg", "balance.net_kg"]
caps[name] = {"availability": "implemented", "visibility": "agent",
"kind": "query" if name == "balance.reading" else "simulation" if name.startswith("scene.") else "device_command",
"description_zh": description, "input_schema": _xpr_object(inputs), "output_schema": _xpr_object(outputs),
"example_arguments": [example], "state_effects": [{"state_id": sid, "timing": "immediate", "description_zh": description} for sid in effects],
"observes": observes, "scene_backend_required": name.startswith("scene."),
"binding": f"basic40_runtime_measure.XPR204ESession.invoke(instance_id=..., capability_id='{name}', arguments=..., request_id=...)",
"completion_criterion_zh": "同步提交声明状态;读数稳定需等待宿主推进与随后观测。",
"preconditions_zh": ("稳定、供电、未锁定校准,且所选质量与滤波力能得到有限增益。" if name == "balance.calibrate_span" else
"稳定且供电。" if name in ("balance.tare", "balance.zero") else
"同步场景回调已注册。" if name.startswith("scene.") else "参数与声明范围匹配。")}
parameters = {
"capacity_kg": {"value": XPR204E_CAPACITY_KG, "unit": "kg", "evidence": "catalog", "source": "CHEM-001 XPR204E catalogue row; same as migrated PX224E"},
"readability_kg": {"value": XPR204E_READABILITY_KG, "unit": "kg", "evidence": "catalog", "source": "CHEM-001 XPR204E catalogue row; same as migrated PX224E; not accuracy"},
"target_repeatability_kg": {"value": 4e-8, "unit": "kg", "evidence": "catalog", "source": "XPR204E target only, not a fitted simulation noise parameter"},
"target_settling_s": {"value": XPR204E_TARGET_SETTLING_S, "unit": "s", "evidence": "catalog", "source": "XPR204E catalogue target; does not guarantee simulated total response time"},
"stability_hold_s": {"value": XPR204E_TARGET_SETTLING_S, "unit": "s", "evidence": "engineering_assumption", "source": "Reuse target value as synthetic rolling-window hold duration"},
"legacy_px224e_hold_s": {"value": 3.0, "unit": "s", "evidence": "code_behavior", "source": "Unmodified scripts/balance_runtime.py Balance.for_model('PX224E')"},
"filter_levels": {"value": _xpr_copy.deepcopy(XPR204E_FILTERS), "unit": "1", "evidence": "engineering_assumption", "source": "Only level names/order follow PX manual EN-27 section 5.3.3; tau and N are not provided by either manufacturer"},
"underload_lower_bound_kg": {"value": {level: -setting["stability_divisions"] * XPR204E_READABILITY_KG for level, setting in XPR204E_FILTERS.items()}, "unit": "kg", "evidence": "engineering_assumption", "source": "Underload is filtered gross below -N*d; near-zero negative noise is displayed without clipping and does not reset stability merely because a raw sample is negative"},
"manufacturer_underload_threshold_kg": {"value": None, "unit": "kg", "evidence": "unknown", "source": "No manufacturer lower detection threshold was supplied"},
"startup_time_constants": {"value": 5.0, "unit": "1", "evidence": "engineering_assumption", "source": "Five-tau startup bounds residual of first noisy sample; not vendor firmware"},
"zero_capture_fraction": {"value": 0.02, "unit": "1", "evidence": "engineering_assumption", "source": "Inherited legacy runtime capture rule"},
"minimum_calibration_input_kg": {"value": XPR204E_CALIBRATION_MIN_KG, "unit": "kg", "evidence": "engineering_assumption", "source": "Numerical API envelope prevents effectively zero denominator; not a practical or manufacturer calibration mass"},
"manufacturer_calibration_mass_kg": {"value": None, "unit": "kg", "evidence": "unknown", "source": "No manufacturer procedure or required calibration mass is implemented"},
"calibration_error_kg": {"value": None, "unit": "kg", "evidence": "unknown", "source": "No measured calibration error or fault data supplied"},
}
return {"asset_types": {XPR204E_TYPE: {"catalog_id": "CHEM-001", "model": "METTLER TOLEDO XPR204E target / PX224E geometry family",
"asset_version": "1.0.1", "state_slots": slots, "capabilities": caps, "parameters": parameters}},
"scene_snapshot_keys": list(XPR204E_SCENE_KEYS),
"scene_snapshot_schema": _xpr_object({sid: slots[sid]["value_schema"] for sid in XPR204E_SCENE_KEYS}),
"trusted_scene_callback": "scene_adapter(instance_id, updates): each call receives the full typed scene snapshot; raw force, unquantized filter, gain and zero truth are excluded",
"host_capabilities": {
"sim.step": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "XPR204ERuntime.step(dt_s, pan_load_forces_N=...)"},
"host.set_environment": {"kind": "configuration", "visibility": "trusted_host_only", "binding": "XPR204ERuntime.set_environment(instance_id, tilt_rad=..., vibration=...)"}},
"limitations": ["All reported measurement results are synthetic and quality=estimated.",
"N is full displayed peak-to-peak range, not manufacturer repeatability or accuracy.",
"High white-force noise requires coarse stability bands (Low 51.2mg, Medium 25.6mg, High 12.8mg).",
"Underload uses a synthetic filtered lower bound of -N*d so noisy empty-pan readings can settle; this is not a manufacturer underload specification.",
"AZT is not implemented; its 0.5d/1d/3d per-second drift settings are not stability thresholds.",
"No contact solver, supported-force aggregation, robot action, real balance driver or fault calibration.",
"No filesystem/process sandbox; deploy the trusted host separately from untrusted execution.",
"Deduplication is in-memory only and does not survive a restart."]}
class XPR204ERuntime:
"""Trusted multi-instance host; only sessions should be exposed to agents."""
def __init__(self, *, scene_adapter=None):
self.scene_adapter = scene_adapter
self.time_s = 0.0
self._instances = {}
self._principals = {"__public_agent__": ("agent", None)}
self._requests = {}
self._logs = {"__public_agent__": []}
self._lock = _xpr_threading.RLock()
self._metadata = export_xpr204e_contract_metadata()
self._agent = XPR204ESession(self, "__public_agent__")
def create_instance(self, instance_id, asset_type_id=XPR204E_TYPE):
with self._lock:
if not isinstance(instance_id, str) or not instance_id or instance_id in self._instances or asset_type_id != XPR204E_TYPE:
raise ValueError("Unique nonempty instance ID and declared asset type required")
inst = {"balance": FilteredAnalyticalBalance(), "doors": {side: 0.0 for side in ("left", "right", "top")},
"vibration": False, "tilt_rad": 0.0, "revision": 0}
if self.scene_adapter:
self.scene_adapter(instance_id, self._scene(inst))
self._instances[instance_id] = inst
def register_principal(self, principal_id, *, visibility, instance_ids=None):
with self._lock:
if not isinstance(principal_id, str) or not principal_id or principal_id in self._principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Invalid or already registered host identity")
scope = None if instance_ids is None else frozenset(instance_ids)
if scope is not None and not scope <= self._instances.keys():
raise ValueError("Unknown instance in identity scope")
self._principals[principal_id] = (visibility, scope)
self._logs[principal_id] = []
def session(self, principal_id):
if principal_id not in self._principals:
raise ValueError("Identity must be registered by trusted host")
return XPR204ESession(self, principal_id)
def describe(self, **kwargs):
return self._agent.describe(**kwargs)
def read(self, **kwargs):
return self._agent.read(**kwargs)
def invoke(self, **kwargs):
return self._agent.invoke(**kwargs)
def write(self, **kwargs):
return self._agent.write(**kwargs)
def describe_host(self):
return _xpr_copy.deepcopy(self._metadata["host_capabilities"])
@staticmethod
def _values(inst):
b = inst["balance"]
r = b.read()
observable = r["status"] in ("STABLE", "UNSTABLE") and b.filtered_force_N is not None
values = {"power.enabled": b.powered, "balance.filter_level": b.filter_level, "balance.display_unit": b.unit,
"balance.status": r["status"], "balance.stable": r["stable"],
"balance.gross_kg": _xpr_quantize(b.gross_kg) if observable else None,
"balance.net_kg": r["net_kg"], "balance.tare_kg": _xpr_quantize(b.tare_kg),
"balance.calibrated": b.calibrated, "balance.task_ready": r["task_ready"], "balance.synthetic": True,
"balance.raw_force_n": b.raw_force_N, "balance.filtered_force_n": b.filtered_force_N,
"balance.gain_n_kg": b.g_cal, "balance.zero_kg": b.zero_kg, "balance.stability_elapsed_s": b.elapsed_s,
"pan.installed": b.pan_installed, "environment.tilt_rad": inst["tilt_rad"], "environment.vibration": inst["vibration"]}
values.update({f"door.{side}.opening_m": value for side, value in inst["doors"].items()})
return values
def debug_snapshot(self):
with self._lock:
return {"time_s": self.time_s, "instances": {key: {"revision": inst["revision"], "state": _xpr_copy.deepcopy(self._values(inst)),
"filter_history": list(inst["balance"]._stability_samples), "filter_age_s": inst["balance"].filter_age_s}
for key, inst in self._instances.items()}}
def _scene(self, inst):
values = self._values(inst)
return {sid: values[sid] for sid in XPR204E_SCENE_KEYS}
def set_environment(self, instance_id, *, tilt_rad=0.0, vibration=False):
if not _xpr_number(tilt_rad) or abs(tilt_rad) > _xpr_math.pi / 2 or type(vibration) is not bool:
raise ValueError("Finite tilt within +/-pi/2 and boolean vibration required")
with self._lock:
if instance_id not in self._instances:
raise ValueError("Unknown instance")
inst = self._instances[instance_id]
inst["tilt_rad"], inst["vibration"] = float(tilt_rad), vibration
inst["balance"].tilt_rad = float(tilt_rad)
inst["balance"].reset_stability()
inst["revision"] += 1
def step(self, dt_s, *, pan_load_forces_N=None):
"""Force values are supported pan load (exclude pan weight), held for dt.
This call advances every registered instance under one clock. Missing
values retain the preceding trusted force input. Numerical substeps are
at most 0.01 s; they do not create new independent contact-force samples.
A callback failure leaves process/time advanced and raises RuntimeError.
"""
if not _xpr_number(dt_s) or not 0 <= dt_s <= 60:
raise ValueError("Finite host interval within 0..60 s required")
forces = {} if pan_load_forces_N is None else pan_load_forces_N
if not isinstance(forces, dict) or any(not isinstance(key, str) or not _xpr_number(value) for key, value in forces.items()):
raise ValueError("Supported force mapping must contain finite SI values")
with self._lock:
if any(key not in self._instances for key in forces):
raise ValueError("Unknown force target")
if dt_s == 0:
return
n = max(1, int(_xpr_math.ceil(dt_s / 0.01)))
h = dt_s / n
for key, inst in self._instances.items():
b = inst["balance"]
force = forces.get(key, b.raw_force_N)
door_fraction = max(inst["doors"].values()) / XPR204E_DOOR_MAX_M
for _ in range(n):
b.update(force, h, door_fraction=door_fraction, tilt_rad=inst["tilt_rad"], vibration=inst["vibration"])
inst["revision"] += 1
self.time_s += dt_s
if self.scene_adapter:
failed = []
for key, inst in self._instances.items():
try:
self.scene_adapter(key, self._scene(inst))
except Exception:
failed.append(key)
if failed:
raise RuntimeError("Process and common clock advanced; scene synchronization failed") from None
class XPR204ESession:
"""Uniform describe/read/invoke/write interface with host-assigned identity."""
def __init__(self, host, principal_id):
self.__host, self.__principal = host, principal_id
def _visible(self, slot):
return slot["visibility"] == "agent" or self.__host._principals[self.__principal][0] in ("debug", "evaluator")
def _instance(self, instance_id):
if not isinstance(instance_id, str):
return None
_, scope = self.__host._principals[self.__principal]
return self.__host._instances.get(instance_id) if scope is None or instance_id in scope else None
def _envelope(self, instance_id, request_id=None, *, result=None, observations=None, status="succeeded", error=None):
inst = self._instance(instance_id)
return {"protocol_version": "1.0.0", "instance_id": instance_id if isinstance(instance_id, str) else None,
"request_id": request_id if isinstance(request_id, str) else None, "operation_id": None, "status": status,
"state_revision": inst["revision"] if inst else None, "clock": {"domain": "simulation", "time_s": self.__host.time_s},
"result": {} if result is None else _xpr_copy.deepcopy(result), "observations": {} if observations is None else _xpr_copy.deepcopy(observations), "error": error}
def _error(self, instance_id, code, request_id=None, status="rejected"):
messages = {"UNKNOWN_INSTANCE": "Instance is unavailable in this session.", "UNKNOWN_CAPABILITY": "Capability is unavailable.",
"INVALID_ARGUMENT": "Arguments do not meet declared schema or limits.", "ACCESS_DENIED": "Request is outside session access policy.",
"PRECONDITION_FAILED": "Required operating state or configuration is unavailable.",
"REQUEST_CONFLICT": "Request ID already belongs to different arguments.", "UNSUPPORTED": "Execution is unavailable in this adapter.",
"DEVICE_ERROR": "Scene callback did not complete the command."}
return self._envelope(instance_id, request_id, status=status, error={"code": code, "message": messages[code],
"retryable": False, "side_effects": "unknown" if code == "DEVICE_ERROR" else "none", "progress": None})
def describe(self, *, asset_type_id=None, instance_id=None):
host = self.__host
with host._lock:
if (asset_type_id is None) == (instance_id is None):
return self._error(None, "INVALID_ARGUMENT")
if instance_id is not None and not self._instance(instance_id):
return self._error(instance_id, "UNKNOWN_INSTANCE")
if asset_type_id is not None and asset_type_id != XPR204E_TYPE:
return self._error(None, "INVALID_ARGUMENT")
_, scope = host._principals[self.__principal]
if scope is not None and not scope:
return self._error(instance_id, "ACCESS_DENIED")
spec = _xpr_copy.deepcopy(host._metadata["asset_types"][XPR204E_TYPE])
spec["state_slots"] = {sid: value for sid, value in spec["state_slots"].items() if self._visible(value)}
for cap in spec["capabilities"].values():
cap["state_effects"] = [effect for effect in cap["state_effects"] if effect["state_id"] in spec["state_slots"]]
cap["observes"] = [sid for sid in cap["observes"] if sid in spec["state_slots"]]
if cap["scene_backend_required"] and host.scene_adapter is None:
cap["availability"] = "unsupported"
return {"protocol_version": "1.0.0", "asset_type_id": XPR204E_TYPE, "instance_id": instance_id,
"adapter": "basic40_runtime_measure.XPR204ESession", **spec,
"limitations": _xpr_copy.deepcopy(host._metadata["limitations"])}
def read(self, *, instance_id, state_ids=None):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if not inst:
return self._error(instance_id, "UNKNOWN_INSTANCE")
slots = host._metadata["asset_types"][XPR204E_TYPE]["state_slots"]
if state_ids is None:
state_ids = [sid for sid, value in slots.items() if self._visible(value)]
if not isinstance(state_ids, list) or any(not isinstance(sid, str) for sid in state_ids) or len(state_ids) != len(set(state_ids)):
return self._error(instance_id, "INVALID_ARGUMENT")
if any(sid not in slots or not self._visible(slots[sid]) for sid in state_ids):
return self._error(instance_id, "ACCESS_DENIED")
values = host._values(inst)
observations = {sid: {"value": values[sid], "unit": slots[sid]["unit"],
"quality": "unavailable" if values[sid] is None else "estimated" if slots[sid]["origin"] == "derived" else "valid",
"sample_time_s": host.time_s, "sample_window_s": None,
"reason": "No reading is available in the current acquisition, power, pan or range state." if values[sid] is None else None,
"synthetic": slots[sid]["origin"] == "derived"} for sid in state_ids}
return self._envelope(instance_id, observations=observations)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if not inst:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
if not isinstance(capability_id, str) or not isinstance(arguments, dict) or not isinstance(request_id, str) or not request_id or len(request_id) > 256:
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
try:
digest = _xpr_hashlib.sha256(_xpr_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False).encode()).hexdigest()
except (TypeError, ValueError, OverflowError):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
key = (self.__principal, instance_id, request_id)
if key in host._requests:
old_digest, response = host._requests[key]
return _xpr_copy.deepcopy(response) if digest == old_digest else self._error(instance_id, "REQUEST_CONFLICT", request_id)
response = self._checked(instance_id, inst, capability_id, arguments, request_id)
host._requests[key] = (digest, _xpr_copy.deepcopy(response))
host._logs[self.__principal].append({"instance_id": instance_id, "capability_id": capability_id, "request_id": request_id,
"response": _xpr_copy.deepcopy(response)})
return response
def _checked(self, instance_id, inst, cap, args, request_id):
host = self.__host
fail = lambda code, status="rejected": self._error(instance_id, code, request_id, status)
spec = host._metadata["asset_types"][XPR204E_TYPE]
if cap not in spec["capabilities"]:
return fail("UNKNOWN_CAPABILITY")
if set(args) != set(spec["capabilities"][cap]["input_schema"]["properties"]):
return fail("INVALID_ARGUMENT")
if cap == "power.set" and type(args["enabled"]) is not bool:
return fail("INVALID_ARGUMENT")
if cap == "balance.set_filter" and (not isinstance(args["level"], str) or args["level"] not in XPR204E_FILTERS):
return fail("INVALID_ARGUMENT")
if cap == "balance.set_display_unit" and args["unit"] not in ("kg", "g"):
return fail("INVALID_ARGUMENT")
if cap == "balance.calibrate_span" and (not _xpr_number(args["known_mass_kg"]) or not XPR204E_CALIBRATION_MIN_KG <= args["known_mass_kg"] <= XPR204E_CAPACITY_KG):
return fail("INVALID_ARGUMENT")
if cap == "scene.set_door" and (args["side"] not in ("left", "right", "top") or not _xpr_number(args["opening_m"]) or not 0 <= args["opening_m"] <= XPR204E_DOOR_MAX_M):
return fail("INVALID_ARGUMENT")
if cap == "scene.set_pan" and type(args["installed"]) is not bool:
return fail("INVALID_ARGUMENT")
b = inst["balance"]
if cap in ("balance.tare", "balance.zero", "balance.calibrate_span") and (not b.powered or not b.stable):
return fail("PRECONDITION_FAILED")
if cap == "balance.zero" and abs(b.gross_kg) > 0.02 * b.capacity_kg:
return fail("PRECONDITION_FAILED")
if cap == "balance.calibrate_span" and (b.security_locked or b.filtered_force_N is None or b.filtered_force_N <= 0):
return fail("PRECONDITION_FAILED")
if cap == "balance.set_filter" and b.security_locked:
return fail("PRECONDITION_FAILED")
if cap == "scene.set_pan" and (b.powered or abs(b.raw_force_N / b.g_cal) > b.readability_kg):
return fail("PRECONDITION_FAILED")
if cap.startswith("scene.") and host.scene_adapter is None:
return fail("UNSUPPORTED", "unsupported")
if cap == "balance.reading":
values = host._values(inst)
return self._envelope(instance_id, request_id, result={"status": values["balance.status"], "stable": values["balance.stable"],
"gross_kg": values["balance.gross_kg"], "net_kg": values["balance.net_kg"], "synthetic": True})
candidate = _xpr_copy.deepcopy(inst)
b = candidate["balance"]
if cap == "power.set":
b.set_power(args["enabled"])
result = {"enabled": b.powered}
elif cap == "balance.set_filter":
b.set_filter(args["level"])
result = {"level": b.filter_level}
elif cap == "balance.tare":
b.press("tare")
result = {"tare_kg": _xpr_quantize(b.tare_kg)}
elif cap == "balance.zero":
b.press("zero")
result = {"zeroed": True}
elif cap == "balance.set_display_unit":
b.unit = args["unit"]
result = {"unit": b.unit}
elif cap == "balance.calibrate_span":
try:
b.calibrate_known_mass(args["known_mass_kg"])
except ValueError:
return fail("PRECONDITION_FAILED")
result = {"calibrated": True, "synthetic": True}
elif cap == "scene.set_door":
candidate["doors"][args["side"]] = float(args["opening_m"])
b.door_fraction = max(candidate["doors"].values()) / XPR204E_DOOR_MAX_M
b.reset_stability()
result = {"side": args["side"], "opening_m": float(args["opening_m"])}
else:
b.pan_installed = b.pan_latched = args["installed"]
b.reset_stability()
result = {"installed": b.pan_installed}
if host.scene_adapter:
try:
host.scene_adapter(instance_id, host._scene(candidate))
except Exception:
return fail("DEVICE_ERROR", "failed")
candidate["revision"] += 1
host._instances[instance_id] = candidate
return self._envelope(instance_id, request_id, result=result)
def write(self, *, instance_id, state_id, value, request_id):
host = self.__host
with host._lock:
if not self._instance(instance_id):
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
slots = host._metadata["asset_types"][XPR204E_TYPE]["state_slots"]
if not isinstance(state_id, str) or state_id not in slots or not self._visible(slots[state_id]) or not slots[state_id]["write_via"]:
return self._error(instance_id, "ACCESS_DENIED", request_id)
route = slots[state_id]["write_via"]
arguments = {**route["fixed_arguments"], route["parameter"]: value}
return self.invoke(instance_id=instance_id, capability_id=route["capability_id"], arguments=arguments, request_id=request_id)
def logs(self):
with self.__host._lock:
return _xpr_copy.deepcopy(self.__host._logs[self.__principal])
def xpr204e_filter_experiments(*, seeds=range(10), duration_s=60.0):
"""Specified 100 Hz Gaussian-force test, including baseline and display error.
These are fixed 100 g and empty-pan synthetic fixtures, not task/sample truth.
Results only characterize this uncorrelated-noise experiment, not arbitrary
contact noise.
"""
import platform
seeds = tuple(seeds)
trials, empty_pan_trials = [], []
dt = 0.01
for load, fixture_trials in ((0.1, trials), (0.0, empty_pan_trials)):
for level in XPR204E_FILTERS:
for sigma in (1e-6, 1e-4, 1e-3):
for seed in seeds:
rng = _xpr_random.Random(seed)
balance = FilteredAnalyticalBalance(filter_level=level)
balance.set_power(True)
first = None
stable_error = None
for index in range(1, int(duration_s / dt) + 1):
result = balance.update(load * 9.80665 + rng.gauss(0, sigma), dt)
if result["stable"]:
first = round(index * dt, 8)
stable_error = result["net_kg"] - load
break
fixture_trials.append({"level": level, "reference_load_kg": load, "sigma_force_N": sigma, "seed": seed,
"first_stable_s": first, "net_error_at_first_stable_kg": stable_error,
"filtered_peak_to_peak_at_stable_kg": balance._window_range_kg,
"result": "passed" if first is not None else "failed"})
baseline = []
for sigma in (1e-6, 1e-4, 1e-3):
rng = _xpr_random.Random(0)
balance = _XPRLegacyBalance.for_model("PX224E")
balance.press("zero")
first = None
for index in range(1, int(duration_s / dt) + 1):
if balance.update(0.1 * 9.80665 + rng.gauss(0, sigma), dt)["stable"]:
first = round(index * dt, 8)
break
baseline.append({"sigma_force_N": sigma, "first_stable_s": first, "duration_s": duration_s})
return {"catalog_id": "CHEM-001", "recorded_at": _xpr_datetime.now(_xpr_timezone.utc).isoformat(),
"environment": {"python": platform.python_version(), "platform": platform.platform()},
"method": "100 Hz independent Gaussian force noise on 0.1 kg and empty-pan synthetic fixtures; first STABLE within 60 s",
"synthetic": True, "noise_distribution": "independent Gaussian; zero mean", "dt_s": dt,
"duration_s": duration_s, "seed_values": list(seeds), "filter_parameters": _xpr_copy.deepcopy(XPR204E_FILTERS),
"numeric_filter_evidence": "engineering_assumption", "manufacturer_filter_numbers": None,
"manufacturer_level_evidence": "references/PX_manual.txt lines 1161-1168; section 5.3.3, EN-27",
"stability_hold_s": XPR204E_TARGET_SETTLING_S, "warmup": "5*tau from filter initialization",
"baseline_unmodified_px224e": baseline, "trials": trials, "empty_pan_trials": empty_pan_trials,
"result": "passed" if all(row["result"] == "passed" for row in trials + empty_pan_trials) else "failed",
"boundaries": "STABLE means a full filtered display window is within N divisions; coarse high-noise bands do not reproduce the XPR204E 0.04 mg typical repeatability. No correlated/bias/contact-solver noise, actual hardware, robot or process/filesystem isolation was validated."}
def write_xpr204e_runtime_reports(output_directory):
"""Write only the caller-designated asset output directory; no global files."""
import importlib.util
import io
import platform
import unittest
root = _xpr_Path(__file__).resolve().parents[1]
spec = importlib.util.spec_from_file_location("test_basic40_measure", root / "tests/test_basic40_measure.py")
module = importlib.util.module_from_spec(spec)
spec.loader.exec_module(module)
suite = unittest.defaultTestLoader.loadTestsFromTestCase(module.XPR204ERuntimeTests)
suite.addTests(unittest.defaultTestLoader.loadTestsFromTestCase(module.FilteredAnalyticalBalanceTests))
stream = io.StringIO()
result = unittest.TextTestRunner(stream=stream, verbosity=2).run(suite)
report = {"catalog_id": "CHEM-001", "recorded_at": _xpr_datetime.now(_xpr_timezone.utc).isoformat(),
"environment": {"python": platform.python_version(), "platform": platform.platform()},
"method": "unittest runtime inputs, state transitions, noise window, two instances, API truth filtering, request retry and scene callback failure",
"tests_run": result.testsRun, "failures": len(result.failures), "errors": len(result.errors),
"result": "passed" if result.wasSuccessful() else "failed", "output": stream.getvalue(),
"not_run": ["real_hardware", "robot_execution", "contact_solver", "process_filesystem_security_isolation"],
"scene_scope": "A recording callback checks synchronization, not evaluated Blender geometry."}
directory = _xpr_Path(output_directory)
directory.mkdir(parents=True, exist_ok=True)
for name, value in (("runtime_validation.json", report), ("filter_experiments.json", xpr204e_filter_experiments()),
("runtime_metadata.json", export_xpr204e_contract_metadata())):
(directory / name).write_text(_xpr_json.dumps(value, ensure_ascii=False, indent=2) + "\n", encoding="utf-8")
return report
# CHEM-103 append-only runtime: catalogue limits and synthetic command playback.
import copy as _gamry_copy
import hashlib as _gamry_hashlib
import json as _gamry_json
import math as _gamry_math
import threading as _gamry_threading
from fractions import Fraction as _gamry_Fraction
GAMRY_REFERENCE620_TYPE = "instrument.gamry_reference620"
GAMRY_REFERENCE620_PORTS = ("working_electrode", "reference_electrode", "counter_electrode", "cell")
GAMRY_REFERENCE620_MIN_INTERVAL_S = 3.333e-6
GAMRY_REFERENCE620_MAX_SAMPLES = 10000 # Runtime resource budget, not a vendor specification.
GAMRY_REFERENCE620_TEMPLATE_CAPABILITIES = ("template.list", "template.read", "electrochem.template_cv")
def _gamry_template_module():
"""Lazy import of the public-data template extension (scripts/basic40_templates/gamry_ref620.py)."""
try:
from .basic40_templates import gamry_ref620 as module
except ImportError:
from basic40_templates import gamry_ref620 as module
return module
def _gamry_number(value):
try:
return type(value) in (int, float) and _gamry_math.isfinite(value)
except (TypeError, OverflowError):
return False
def _gamry_object(properties):
return {"type": "object", "properties": properties, "required": list(properties), "additionalProperties": False}
def _gamry_num(unit, minimum=None, maximum=None, nullable=False):
spec = {"type": "number", "x-unit": unit}
if minimum is not None:
spec["minimum"] = minimum
if maximum is not None:
spec["maximum"] = maximum
return {"anyOf": [spec, {"type": "null"}]} if nullable else spec
def export_gamry_reference620_contract_metadata():
"""Static contract metadata. No live samples or host identities are exported."""
boolean = {"type": "boolean"}
synthetic = {"type": "boolean", "const": True}
nullable_id = {"anyOf": [{"type": "string", "minLength": 1}, {"type": "null"}]}
status_schema = {"type": "string", "enum": ["idle", "running", "completed", "stopped"]}
program_variants = []
for mode, unit, limit in (("potential", "V", 11.0), ("current", "A", 0.6)):
program_variants.append(_gamry_object({"mode": {"type": "string", "const": mode},
"sample_interval_s": _gamry_num("s", GAMRY_REFERENCE620_MIN_INTERVAL_S),
"values": {"type": "array", "items": _gamry_num(unit, -limit, limit),
"minItems": 1, "maxItems": GAMRY_REFERENCE620_MAX_SAMPLES}}))
program_schema = {"anyOf": program_variants}
sample_schema = _gamry_object({"time_s": _gamry_num("s", 0), "elapsed_s": _gamry_num("s", 0),
"commanded_potential_v": _gamry_num("V", -11, 11, True),
"commanded_current_a": _gamry_num("A", -0.6, 0.6, True),
"measured_potential_v": {"type": "null"}, "measured_current_a": {"type": "null"},
"synthetic": synthetic})
series_schema = {"type": "array", "items": sample_schema, "maxItems": GAMRY_REFERENCE620_MAX_SAMPLES}
slots = {}
def slot(sid, unit, origin, schema, description, route=None, visibility="agent", sampling="instant"):
slots[sid] = {"description_zh": description, "value_schema": schema, "unit": unit,
"origin": origin, "visibility": visibility, "access": "read_write" if route else "read_only",
"write_via": route, "reference_conditions": None,
"read_binding": "GamryReference620Session.read(instance_id=..., state_ids=[state_id])",
"sampling": {"mode": sampling, "time_domain": "simulation", "window": None}}
def route(capability_id, parameter, fixed_arguments=None):
return {"capability_id": capability_id, "parameter": parameter, "fixed_arguments": fixed_arguments or {}}
slot("power.enabled", "1", "setpoint", boolean, "供电逻辑状态;关电立即停止命令输出。", route("power.set", "enabled"))
for port in GAMRY_REFERENCE620_PORTS:
slot("slot." + port + ".connection_id", "1", "scene", nullable_id,
"宿主场景连接槽的逻辑引用;null表示未连接,不证明接触或机器人接线已完成。",
route("slot.set_connection", "connection_id", {"port_id": port}))
slot("waveform.program", "1", "setpoint", {"anyOf": program_variants + [{"type": "null"}]},
"显式离散命令程序;电位与电流互斥;采样间隔须不小于表列最小时间基准。",
route("electrochem.configure_waveform", "program"))
slot("waveform.status", "1", "derived", status_schema, "离散播放状态,不代表真实样本实验完成。")
slot("waveform.running", "1", "derived", boolean, "是否等待宿主推进来播放剩余命令。")
slot("waveform.sample_count", "1", "derived", {"type": "integer", "minimum": 0, "maximum": GAMRY_REFERENCE620_MAX_SAMPLES, "x-unit": "1"}, "已播放命令点数。")
slot("waveform.elapsed_s", "s", "derived", _gamry_num("s", 0), "本次播放已推进的有效时间,完成后停在最后命令点。")
slot("output.commanded_potential_v", "V", "derived", _gamry_num("V", -11, 11, True), "当前合成电位命令;停止或使用电流模式时为null。")
slot("output.commanded_current_a", "A", "derived", _gamry_num("A", -0.6, 0.6, True), "当前合成电流命令;停止或使用电位模式时为null。")
slot("acquisition.series", "1", "derived", series_schema, "按时间排列的命令回放序列;两种实测通道均为null。", sampling="series")
slot("acquisition.synthetic", "1", "derived", synthetic, "本适配器产生的序列始终标记synthetic。")
for sid, unit, desc in (("measurement.potential_v", "V", "未接入真实电位传感器;无响应模型。"),
("measurement.current_a", "A", "未接入真实电流传感器;无响应模型。"),
("method.scan_rate_v_s", "V/s", "未配置连续扫描速率;本批仅显式离散程序。"),
("method.frequency_hz", "Hz", "未配置EIS频率;EIS执行不支持。"),
("method.amplitude_v", "V", "未配置EIS振幅;无虚构默认值。"),
("method.ir_compensation_ohm", "ohm", "未提供iR补偿参数,保持未知。")):
slot(sid, unit, "sensor" if sid.startswith("measurement.") else "setpoint", {"type": "null"}, desc)
slot("scheduler.started_at_s", "s", "process_truth", _gamry_num("s", 0, nullable=True),
"宿主内部调度起点;仅debug/evaluator可见。", visibility="debug")
playback_effects = ["waveform.status", "waveform.running", "waveform.sample_count", "waveform.elapsed_s",
"output.commanded_potential_v", "output.commanded_current_a", "acquisition.series", "scheduler.started_at_s"]
stop_effects = ["waveform.status", "waveform.running", "output.commanded_potential_v", "output.commanded_current_a"]
connection_inputs = {"port_id": {"type": "string", "enum": list(GAMRY_REFERENCE620_PORTS)}, "connection_id": nullable_id}
series_result = {"samples": series_schema, "synthetic": synthetic,
"response_model": {"type": "null"}, "status": status_schema}
definitions = {
"power.set": ({"enabled": boolean}, {"enabled": boolean}, {"enabled": True},
"设置逻辑电源;关电保留已播放序列并停止输出。", ["power.enabled"] + stop_effects, ["power.enabled"], "device_command", ["body"], "参数为布尔值。"),
"slot.set_connection": (connection_inputs, connection_inputs, {"port_id": "working_electrode", "connection_id": "electrode_we_01"},
"登记或清除单个逻辑连接槽;不执行机械接线。", ["slot." + p + ".connection_id" for p in GAMRY_REFERENCE620_PORTS],
["slot." + p + ".connection_id" for p in GAMRY_REFERENCE620_PORTS], "configuration",
[p + "_slot" for p in GAMRY_REFERENCE620_PORTS], "不得处于播放状态;连接引用为非空字符串或null。"),
"electrochem.configure_waveform": ({"program": program_schema}, {"program": program_schema},
{"program": {"mode": "potential", "sample_interval_s": 0.01, "values": [-1.0, 0.0, 1.0]}},
"配置显式离散电位或电流命令,清空上一轮序列;不推导扫描速率或样本响应。",
["waveform.program"] + playback_effects, ["waveform.program"], "configuration", ["body"],
"不得处于播放状态;全部数值有限,电位±11V、电流±0.6A,间隔≥3.333e-6s。"),
"electrochem.start": ({}, {"status": status_schema, "synthetic": synthetic}, {},
"开始等待宿主时钟播放离散程序;此调用不产生样点也不推进时间。", playback_effects,
["waveform.status", "waveform.running"], "device_command", ["body"] + [p + "_slot" for p in GAMRY_REFERENCE620_PORTS],
"电源开启、四槽均已连接、程序已配置且当前未播放;整份计划的输出时间戳必须有限且逐点严格递增。"),
"electrochem.stop": ({}, {"status": status_schema, "synthetic": synthetic}, {},
"停止尚未播放的命令,保留已播放序列;输出设为null。", stop_effects,
["waveform.status", "waveform.running"], "device_command", ["body"], "实例可用;允许幂等停止。"),
"electrochem.read_series": ({}, series_result, {}, "只读合成命令序列;真实测量通道为null,不推进时间。",
[], ["acquisition.series", "acquisition.synthetic", "waveform.status"], "query", ["body"], "实例可用。"),
"electrochem.eis": ({}, {}, {}, "表中EIS范围保留为型号规格;本批不生成阻抗谱或虚构成功。",
[], [], "device_command", ["body"], "当前适配器不支持执行EIS。"),
}
caps = {}
for name, (inputs, outputs, example, description, effects, observes, kind, components, preconditions) in definitions.items():
supported = name != "electrochem.eis"
caps[name] = {"availability": "implemented" if supported else "unsupported", "visibility": "agent", "kind": kind,
"description_zh": description, "input_schema": _gamry_object(inputs), "output_schema": _gamry_object(outputs),
"example_arguments": [example], "state_effects": [{"state_id": sid, "timing": "immediate", "description_zh": description} for sid in effects],
"observes": observes, "component_ids": components, "preconditions_zh": preconditions,
"binding": f"basic40_runtime_measure.GamryReference620Session.invoke(instance_id=..., capability_id='{name}', arguments=..., request_id=...)",
"completion_criterion_zh": "同步提交所列逻辑状态;播放完成须由宿主推进并读取completed状态。" if supported else "返回unsupported且无状态变化。",
"model_effects": {"mode": "none", "binding_ids": [], "description_zh": "仅逻辑槽位与离散电命令,不驱动几何或接触求解。"},
"implementation": {"process": "implemented" if supported else "absent", "host": "implemented" if supported else "absent", "scene": "absent", "robot": "absent", "hardware": "absent"},
"error_codes": ["UNKNOWN_INSTANCE", "UNKNOWN_CAPABILITY", "INVALID_ARGUMENT", "ACCESS_DENIED", "PRECONDITION_FAILED", "BUSY", "REQUEST_CONFLICT", "UNSUPPORTED"],
"retry": "same_request_id; in-memory only"}
parameters = {
"potential_limit_v": {"value": 11.0, "unit": "V", "evidence": "catalog", "note_zh": "参数与来源第108行,整机±11V命令限幅。"},
"current_limit_a": {"value": 0.6, "unit": "A", "evidence": "catalog", "note_zh": "参数与来源第108行,±600mA换算SI;不是电极部件参数。"},
"minimum_time_base_s": {"value": GAMRY_REFERENCE620_MIN_INTERVAL_S, "unit": "s", "evidence": "catalog", "note_zh": "表列3.333µs;映射为最小程序点间隔为工程假设。"},
"eis_frequency_range_hz": {"value": [1e-5, 5e6], "unit": "Hz", "evidence": "catalog", "note_zh": "保留型号规格,未实现EIS执行。"},
"maximum_program_samples": {"value": GAMRY_REFERENCE620_MAX_SAMPLES, "unit": "1", "evidence": "engineering_assumption", "note_zh": "本地资源预算,不是厂家最大点数。"},
"cell_resistance_ohm": {"value": None, "unit": "ohm", "evidence": "unknown", "note_zh": "未提供真实电化学池参数。"},
"electrode_area_m2": {"value": None, "unit": "m^2", "evidence": "unknown", "note_zh": "未提供电极几何或有效面积。"},
"calibration_error_v": {"value": None, "unit": "V", "evidence": "unknown", "note_zh": "未提供校准或误差数据。"},
}
return {"asset_types": {GAMRY_REFERENCE620_TYPE: {"catalog_id": "CHEM-103", "model": "Gamry Reference 620", "asset_version": "1.1.0",
"state_slots": slots, "capabilities": caps, "parameters": parameters}},
"host_capabilities": {"sim.step": {"kind": "simulation", "visibility": "trusted_host_only",
"binding": "GamryReference620Runtime.step(dt_s)", "effects": playback_effects,
"semantics_zh": "显式推进所有实例共享时钟;输入数值的十进制表示转精确有理数进行累加和计划比较;正步进播放覆盖的计划点(包括起点),零步进不产生效果。输出仍为SI浮点数,完整计划须严格可分辨。"}},
"limitations": ["All sequence data are synthetic command playback, not electrochemical measurements.",
"Measured potential/current and unprovided cell/method parameters remain null.",
"No EIS, Nernst, Coulomb, sample response, iR compensation, noise, calibration or hardware driver is implemented.",
"Sample playback and minimum-time-base interpretation are engineering assumptions, not vendor firmware emulation.",
"Clock inputs use their shortest decimal string as an exact rational; this numerical convention makes decimal step partitions consistent. Exposed timestamps remain floats; non-monotonic or indistinguishable complete schedules are rejected before start.",
"Slot references are logical only; compatibility, electrical contact and robot connection are not validated.",
"Session filtering is an API boundary only; this is not a Python/filesystem security sandbox.",
"Request deduplication lasts only for this in-memory host lifetime."]}
class GamryReference620Runtime:
"""Trusted host for independent instances under an explicitly stepped clock."""
def __init__(self):
self._time_fraction = _gamry_Fraction(0)
self._instances = {}
self._principals = {"__public_agent__": ("agent", None)}
self._logs = {"__public_agent__": []}
self._requests = {}
self._lock = _gamry_threading.RLock()
self._metadata = export_gamry_reference620_contract_metadata()
self._agent = GamryReference620Session(self, "__public_agent__")
def create_instance(self, instance_id, asset_type_id=GAMRY_REFERENCE620_TYPE):
with self._lock:
if type(instance_id) is not str or not instance_id or instance_id in self._instances or asset_type_id != GAMRY_REFERENCE620_TYPE:
raise ValueError("A unique nonempty instance ID and the declared asset type are required")
self._instances[instance_id] = {"revision": 0, "enabled": False,
"connections": {p: None for p in GAMRY_REFERENCE620_PORTS}, "program": None,
"status": "idle", "running": False, "index": 0, "elapsed_s": 0.0,
"potential_v": None, "current_a": None, "samples": [], "started_at_s": None,
"started_at_fraction": None, "schedule": []}
@property
def time_s(self):
"""Public SI float view of the single authoritative rational host clock."""
return float(self._time_fraction)
def register_principal(self, principal_id, *, visibility, instance_ids=None):
with self._lock:
if type(principal_id) is not str or not principal_id or principal_id in self._principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Invalid or already registered host identity")
if instance_ids is not None and (type(instance_ids) not in (list, tuple, set, frozenset) or any(type(x) is not str for x in instance_ids)):
raise ValueError("Instance scope must be a collection of instance IDs")
scope = None if instance_ids is None else frozenset(instance_ids)
if scope is not None and not scope <= self._instances.keys():
raise ValueError("Unknown instance in identity scope")
self._principals[principal_id] = (visibility, scope)
self._logs[principal_id] = []
def session(self, principal_id):
if type(principal_id) is not str or principal_id not in self._principals:
raise ValueError("Identity must be registered by the trusted host")
return GamryReference620Session(self, principal_id)
def describe(self, **kwargs):
return self._agent.describe(**kwargs)
def read(self, **kwargs):
return self._agent.read(**kwargs)
def invoke(self, **kwargs):
return self._agent.invoke(**kwargs)
def write(self, **kwargs):
return self._agent.write(**kwargs)
def describe_host(self):
return _gamry_copy.deepcopy(self._metadata["host_capabilities"])
def host_load_template_cell(self, instance_id, cell):
"""Trusted host only: attach a template-backed cell (public redox library); agents never see its contents."""
with self._lock:
inst = self._instances.get(instance_id) if type(instance_id) is str else None
if inst is None or inst["running"]:
raise ValueError("A known instance without active playback is required")
inst["template_cell"] = _gamry_template_module().build_cell(cell)
return {"loaded": True, "template_backed": True, "synthetic": False}
@staticmethod
def _values(inst):
values = {"power.enabled": inst["enabled"], "waveform.program": inst["program"],
"waveform.status": inst["status"], "waveform.running": inst["running"],
"waveform.sample_count": inst["index"], "waveform.elapsed_s": inst["elapsed_s"],
"output.commanded_potential_v": inst["potential_v"], "output.commanded_current_a": inst["current_a"],
"acquisition.series": inst["samples"], "acquisition.synthetic": True,
"measurement.potential_v": None, "measurement.current_a": None,
"method.scan_rate_v_s": None, "method.frequency_hz": None,
"method.amplitude_v": None, "method.ir_compensation_ohm": None,
"scheduler.started_at_s": inst["started_at_s"]}
values.update({"slot." + p + ".connection_id": value for p, value in inst["connections"].items()})
return values
def debug_snapshot(self):
with self._lock:
return {"time_s": self.time_s, "instances": {key: {"revision": inst["revision"],
"state": _gamry_copy.deepcopy(self._values(inst))} for key, inst in self._instances.items()}}
def step(self, dt_s):
"""Positive host steps emit scheduled command points, never sample chemistry.
Inputs are interpreted by their shortest decimal representation, then
exact rational addition/comparison controls the host clock and schedule.
Each timestamp comes from the absolute start plus index*interval; chunk
boundaries do not set the sampling cadence. Zero is a pure no-op. The
first point is timestamped at the start but emitted only on a positive
host step. Completion de-energizes the command outputs and retains all
emitted samples. All registered instances share this host clock.
"""
if not _gamry_number(dt_s) or dt_s < 0:
raise ValueError("Finite nonnegative SI host interval required")
with self._lock:
target_fraction = self._time_fraction + _gamry_Fraction(str(dt_s))
try:
target = float(target_fraction)
except OverflowError:
raise ValueError("Host clock exceeds representable range") from None
if not _gamry_number(target) or (dt_s > 0 and target <= self.time_s):
raise ValueError("Host clock interval exceeds representable precision or range")
if dt_s == 0:
return
candidates = _gamry_copy.deepcopy(self._instances)
for inst in candidates.values():
if not inst["running"]:
continue
before = self._values(inst)
program = inst["program"]
duration = inst["schedule"][-1][1]
inst["elapsed_s"] = min(float(target_fraction - inst["started_at_fraction"]), duration)
while inst["index"] < len(program["values"]):
scheduled_fraction, offset = inst["schedule"][inst["index"]]
if scheduled_fraction > target_fraction:
break
timestamp = float(scheduled_fraction)
value = program["values"][inst["index"]]
potential = value if program["mode"] == "potential" else None
current = value if program["mode"] == "current" else None
inst["samples"].append({"time_s": timestamp, "elapsed_s": offset,
"commanded_potential_v": potential, "commanded_current_a": current,
"measured_potential_v": None, "measured_current_a": None, "synthetic": True})
inst["potential_v"], inst["current_a"] = potential, current
inst["index"] += 1
if inst["index"] == len(program["values"]):
inst["running"] = False
inst["status"] = "completed"
inst["potential_v"] = inst["current_a"] = None
if before != self._values(inst):
inst["revision"] += 1
self._instances = candidates
self._time_fraction = target_fraction
class GamryReference620Session:
"""Expose only this facade to agents; identities are assigned by the host."""
def __init__(self, host, principal_id):
self.__host, self.__principal = host, principal_id
def _visible(self, spec):
return spec["visibility"] == "agent" or self.__host._principals[self.__principal][0] in ("debug", "evaluator")
def _instance(self, instance_id):
if type(instance_id) is not str:
return None
_, scope = self.__host._principals[self.__principal]
return self.__host._instances.get(instance_id) if scope is None or instance_id in scope else None
def _envelope(self, instance_id, request_id=None, *, result=None, observations=None, status="succeeded", error=None):
inst = self._instance(instance_id)
return {"protocol_version": "1.0.0", "instance_id": instance_id if type(instance_id) is str else None,
"request_id": request_id if type(request_id) is str else None, "operation_id": None, "status": status,
"state_revision": None if inst is None else inst["revision"],
"clock": {"domain": "simulation", "time_s": self.__host.time_s},
"result": _gamry_copy.deepcopy({} if result is None else result),
"observations": _gamry_copy.deepcopy({} if observations is None else observations), "error": error}
def _error(self, instance_id, code, request_id=None, status="rejected"):
messages = {"UNKNOWN_INSTANCE": "Instance is unavailable in this session.", "UNKNOWN_CAPABILITY": "Capability is unavailable.",
"INVALID_ARGUMENT": "Arguments do not meet the declared schema, finite-number or resource limits.",
"ACCESS_DENIED": "Request is outside the session access policy.",
"PRECONDITION_FAILED": "Required operating state or representable clock configuration is unavailable.",
"BUSY": "Stop active waveform playback before changing this configuration.",
"REQUEST_CONFLICT": "Request ID already belongs to different arguments.",
"UNSUPPORTED": "This execution is unavailable in the current adapter."}
return self._envelope(instance_id, request_id, status=status,
error={"code": code, "message": messages[code], "retryable": False, "side_effects": "none", "progress": None})
def describe(self, *, asset_type_id=None, instance_id=None):
host = self.__host
with host._lock:
if (asset_type_id is None) == (instance_id is None):
return self._error(None, "INVALID_ARGUMENT")
if instance_id is not None and self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
if asset_type_id is not None and asset_type_id != GAMRY_REFERENCE620_TYPE:
return self._error(None, "INVALID_ARGUMENT")
_, scope = host._principals[self.__principal]
if scope is not None and not scope:
return self._error(instance_id, "ACCESS_DENIED")
spec = _gamry_copy.deepcopy(host._metadata["asset_types"][GAMRY_REFERENCE620_TYPE])
spec["state_slots"] = {sid: value for sid, value in spec["state_slots"].items() if self._visible(value)}
spec["capabilities"] = {cid: value for cid, value in spec["capabilities"].items() if self._visible(value)}
spec["capabilities"].update(_gamry_template_module().capability_metadata()) # additive public-data extension
for capability in spec["capabilities"].values():
capability["state_effects"] = [effect for effect in capability["state_effects"] if effect["state_id"] in spec["state_slots"]]
capability["observes"] = [sid for sid in capability["observes"] if sid in spec["state_slots"]]
return {"protocol_version": "1.0.0", "asset_type_id": GAMRY_REFERENCE620_TYPE, "instance_id": instance_id,
"adapter": "basic40_runtime_measure.GamryReference620Session", **spec,
"limitations": _gamry_copy.deepcopy(host._metadata["limitations"])}
def read(self, *, instance_id, state_ids=None):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
slots = host._metadata["asset_types"][GAMRY_REFERENCE620_TYPE]["state_slots"]
if state_ids is None:
state_ids = [sid for sid, value in slots.items() if self._visible(value)]
if type(state_ids) is not list or any(type(sid) is not str for sid in state_ids) or len(state_ids) != len(set(state_ids)):
return self._error(instance_id, "INVALID_ARGUMENT")
if any(sid not in slots or not self._visible(slots[sid]) for sid in state_ids):
return self._error(instance_id, "ACCESS_DENIED")
values = host._values(inst)
observations = {}
for sid in state_ids:
series = sid == "acquisition.series"
derived = slots[sid]["origin"] == "derived"
observations[sid] = {"value": values[sid], "unit": slots[sid]["unit"],
"quality": "unavailable" if values[sid] is None else "estimated" if derived else "valid",
"sample_time_s": host.time_s,
"sample_window_s": [inst["samples"][0]["time_s"], inst["samples"][-1]["time_s"]] if series and inst["samples"] else None,
"reason": slots[sid]["description_zh"] if values[sid] is None else None,
"synthetic": derived}
return self._envelope(instance_id, observations=observations)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
if type(capability_id) is not str or type(arguments) is not dict or type(request_id) is not str or not request_id or len(request_id) > 256:
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
try:
digest = _gamry_hashlib.sha256(_gamry_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False).encode()).hexdigest()
except (TypeError, ValueError, OverflowError, RecursionError):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
key = (self.__principal, instance_id, request_id)
if key in host._requests:
old_digest, response = host._requests[key]
return _gamry_copy.deepcopy(response) if old_digest == digest else self._error(instance_id, "REQUEST_CONFLICT", request_id)
response = self._checked(instance_id, inst, capability_id, arguments, request_id)
host._requests[key] = (digest, _gamry_copy.deepcopy(response))
host._logs[self.__principal].append({"instance_id": instance_id, "capability_id": capability_id,
"request_id": request_id, "response": _gamry_copy.deepcopy(response)})
return response
def _checked(self, instance_id, inst, cap, args, request_id):
host = self.__host
if cap in GAMRY_REFERENCE620_TEMPLATE_CAPABILITIES: # additive public-data extension; legacy capabilities unchanged
return _gamry_template_module().invoke(self, host, instance_id, inst, cap, args, request_id,
evaluator=self._visible({"visibility": "debug"}))
fail = lambda code, status="rejected": self._error(instance_id, code, request_id, status)
capabilities = host._metadata["asset_types"][GAMRY_REFERENCE620_TYPE]["capabilities"]
if cap not in capabilities or not self._visible(capabilities[cap]):
return fail("UNKNOWN_CAPABILITY")
if set(args) != set(capabilities[cap]["input_schema"]["properties"]):
return fail("INVALID_ARGUMENT")
if cap == "electrochem.eis":
return fail("UNSUPPORTED", "unsupported")
if cap == "power.set" and type(args["enabled"]) is not bool:
return fail("INVALID_ARGUMENT")
if cap == "slot.set_connection":
port, connection = args["port_id"], args["connection_id"]
if type(port) is not str or port not in GAMRY_REFERENCE620_PORTS or (connection is not None and (type(connection) is not str or not connection.strip())):
return fail("INVALID_ARGUMENT")
if cap == "electrochem.configure_waveform":
program = args["program"]
if type(program) is not dict or set(program) != {"mode", "sample_interval_s", "values"}:
return fail("INVALID_ARGUMENT")
mode, interval, values = program["mode"], program["sample_interval_s"], program["values"]
if type(mode) is not str or mode not in ("potential", "current") or not _gamry_number(interval) or interval < GAMRY_REFERENCE620_MIN_INTERVAL_S:
return fail("INVALID_ARGUMENT")
limit = 11.0 if mode == "potential" else 0.6
if type(values) is not list or not 1 <= len(values) <= GAMRY_REFERENCE620_MAX_SAMPLES or any(not _gamry_number(v) or not -limit <= v <= limit for v in values):
return fail("INVALID_ARGUMENT")
if not _gamry_number((len(values) - 1) * interval):
return fail("INVALID_ARGUMENT")
if cap in ("slot.set_connection", "electrochem.configure_waveform", "electrochem.start") and inst["running"]:
return fail("BUSY")
if cap == "electrochem.start":
if not inst["enabled"] or inst["program"] is None or not all(inst["connections"].values()):
return fail("PRECONDITION_FAILED")
program = inst["program"]
interval_fraction = _gamry_Fraction(str(program["sample_interval_s"]))
schedule = []
previous_timestamp = None
for index in range(len(program["values"])):
offset_fraction = index * interval_fraction
timestamp_fraction = host._time_fraction + offset_fraction
try:
timestamp = float(timestamp_fraction)
offset = float(offset_fraction)
except OverflowError:
return fail("PRECONDITION_FAILED")
if (not _gamry_number(timestamp) or not _gamry_number(offset)
or (previous_timestamp is not None and timestamp <= previous_timestamp)):
return fail("PRECONDITION_FAILED")
schedule.append((timestamp_fraction, offset))
previous_timestamp = timestamp
if cap == "electrochem.read_series":
return self._envelope(instance_id, request_id, result={"samples": inst["samples"], "synthetic": True,
"response_model": None, "status": inst["status"]})
candidate = _gamry_copy.deepcopy(inst)
if cap == "power.set":
candidate["enabled"] = args["enabled"]
if not args["enabled"]:
if candidate["running"]:
candidate["status"] = "stopped"
candidate["running"] = False
candidate["potential_v"] = candidate["current_a"] = None
result = {"enabled": candidate["enabled"]}
elif cap == "slot.set_connection":
candidate["connections"][args["port_id"]] = args["connection_id"]
result = _gamry_copy.deepcopy(args)
elif cap == "electrochem.configure_waveform":
candidate["program"] = _gamry_copy.deepcopy(args["program"])
candidate.update(status="idle", running=False, index=0, elapsed_s=0.0,
potential_v=None, current_a=None, samples=[], started_at_s=None,
started_at_fraction=None, schedule=[])
result = {"program": candidate["program"]}
elif cap == "electrochem.start":
candidate.update(status="running", running=True, index=0, elapsed_s=0.0,
potential_v=None, current_a=None, samples=[], started_at_s=host.time_s,
started_at_fraction=host._time_fraction, schedule=schedule)
result = {"status": "running", "synthetic": True}
else: # electrochem.stop
if candidate["running"]:
candidate["status"] = "stopped"
candidate["running"] = False
candidate["potential_v"] = candidate["current_a"] = None
result = {"status": candidate["status"], "synthetic": True}
if host._values(candidate) != host._values(inst):
candidate["revision"] += 1
host._instances[instance_id] = candidate
return self._envelope(instance_id, request_id, result=result)
def write(self, *, instance_id, state_id, value, request_id):
host = self.__host
with host._lock:
if self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
slots = host._metadata["asset_types"][GAMRY_REFERENCE620_TYPE]["state_slots"]
if type(state_id) is not str or state_id not in slots or not self._visible(slots[state_id]) or slots[state_id]["write_via"] is None:
return self._error(instance_id, "ACCESS_DENIED", request_id)
route = slots[state_id]["write_via"]
return self.invoke(instance_id=instance_id, capability_id=route["capability_id"],
arguments={**route["fixed_arguments"], route["parameter"]: value}, request_id=request_id)
def logs(self):
with self.__host._lock:
return _gamry_copy.deepcopy(self.__host._logs[self.__principal])
# BEGIN CHEM-005 METROHM 914 APPEND-ONLY RUNTIME
import copy as _m914_copy
import hashlib as _m914_hashlib
import json as _m914_json
import math as _m914_math
import threading as _m914_threading
from decimal import Decimal as _m914_Decimal, ROUND_HALF_UP as _m914_ROUND_HALF_UP
METROHM914_TYPE = "instrument.metrohm_914"
METROHM914_CHANNELS = {"ph": (-13.0, 20.0, "1"), "conductance": (1e-7, 0.5, "S"), "do": (0.0, 0.05, "kg/m3")}
METROHM914_TEMPLATE_CAPABILITIES = ("template.list", "template.read", "electrochemistry.template_reading")
def _m914_template_module():
"""Lazy import of the public-data template extension (scripts/basic40_templates/metrohm_914.py)."""
try:
from .basic40_templates import metrohm_914 as module
except ImportError:
from basic40_templates import metrohm_914 as module
return module
def _m914_number(value):
try:
return type(value) in (int, float) and _m914_math.isfinite(value)
except (TypeError, OverflowError):
return False
def _m914_num(unit, minimum=None, maximum=None, nullable=False):
schema = {"type": "number", "x-unit": unit}
if minimum is not None:
schema["minimum"] = minimum
if maximum is not None:
schema["maximum"] = maximum
return {"anyOf": [schema, {"type": "null"}]} if nullable else schema
def _m914_object(properties):
return {"type": "object", "properties": properties, "required": list(properties), "additionalProperties": False}
def export_metrohm914_contract_metadata():
"""Type metadata only: never contains an instance's host-supplied truth."""
boolean = {"type": "boolean"}
nullable_string = {"anyOf": [{"type": "string"}, {"type": "null"}]}
channel = {"type": "string", "enum": list(METROHM914_CHANNELS)}
def route(cap, parameter, fixed=None):
return {"capability_id": cap, "parameter": parameter, "fixed_arguments": fixed or {}}
def slot(unit, origin, schema, visibility="agent", write=None):
return {"unit": unit, "origin": origin, "visibility": visibility,
"access": "read_write" if write else "read_only", "value_schema": schema,
"write_via": write, "read_binding": "Metrohm914Session.read(instance_id=..., state_ids=[state_id])",
"sampling": {"mode": "instant", "time_domain": "simulation", "window": None}, "reference_conditions": None}
slots = {
"power.enabled": slot("1", "setpoint", boolean, write=route("power.set", "enabled")),
"probe.selected": slot("1", "setpoint", channel, write=route("electrochemistry.select_probe", "slot")),
"temperature.mode": slot("1", "setpoint", {"type": "string", "enum": ["automatic", "manual"]}),
"temperature.manual_k": slot("K", "setpoint", _m914_num("K", nullable=True)),
"temperature.compensation_k": slot("K", "derived", _m914_num("K", nullable=True)),
"endpoint.hold_s": slot("s", "setpoint", _m914_num("s", 0, 3600, nullable=True)),
"endpoint.tolerance_fraction": slot("1", "setpoint", _m914_num("1", 0, 1, nullable=True)),
"endpoint.stable": slot("1", "derived", boolean),
"endpoint.elapsed_s": slot("s", "derived", _m914_num("s", 0)),
"acquisition.interval_s": slot("s", "setpoint", _m914_num("s", 1, 86400), write=route("acquisition.set_interval", "interval_s")),
"acquisition.running": slot("1", "derived", boolean),
"acquisition.record_count": slot("1", "derived", {"type": "integer", "minimum": 0, "x-unit": "1"}),
"measurement.status": slot("1", "derived", {"type": "string", "enum": ["OFF", "PROBE_MISSING", "NO_SAMPLE", "MISSING_CONFIGURATION", "OUT_OF_RANGE", "UNSTABLE", "STABLE", "STALE"]}),
"measurement.ph": slot("1", "derived", _m914_num("1", -13, 20, nullable=True)),
"measurement.potential_v": slot("V", "derived", _m914_num("V", nullable=True)),
"measurement.conductance_s": slot("S", "derived", _m914_num("S", 1e-7, 0.5, nullable=True)),
"measurement.do_kg_m3": slot("kg/m3", "derived", _m914_num("kg/m3", 0, 0.05, nullable=True)),
"measurement.synthetic": slot("1", "derived", {"type": "boolean", "const": True}),
"measurement.sample_time_s": slot("s", "derived", _m914_num("s", 0, nullable=True)),
"display.text": slot("1", "derived", {"type": "string"}),
}
for name in METROHM914_CHANNELS:
slots[f"probe.{name}.installed"] = slot("1", "scene", boolean, write=route("probe.set_installed", "installed", {"slot": name}))
slots[f"probe.{name}.calibrated"] = slot("1", "derived", boolean)
slots[f"probe.{name}.calibration_time_s"] = slot("s", "derived", _m914_num("s", 0, nullable=True))
slots[f"calibration.{name}.offset"] = slot(METROHM914_CHANNELS[name][2], "process_truth", _m914_num(METROHM914_CHANNELS[name][2], nullable=True), "debug")
for sid, unit in (("ph", "1"), ("conductance_s", "S"), ("do_kg_m3", "kg/m3"), ("temperature_k", "K"), ("reference_ph", "1"), ("reference_potential_v", "V"), ("conductance_temp_coefficient_k_inv", "1/K"), ("conductance_reference_temperature_k", "K"), ("standard_ph", "1"), ("standard_conductance_s", "S"), ("standard_do_kg_m3", "kg/m3")):
slots[f"truth.{sid}"] = slot(unit, "process_truth", _m914_num(unit, nullable=True), "debug")
slots["truth.standard_slot"] = slot("1", "process_truth", nullable_string, "debug")
reading_fields = {"slot": channel, "status": slots["measurement.status"]["value_schema"], "stable": boolean,
"ph": slots["measurement.ph"]["value_schema"], "potential_v": _m914_num("V", nullable=True),
"conductance_s": slots["measurement.conductance_s"]["value_schema"],
"do_kg_m3": slots["measurement.do_kg_m3"]["value_schema"], "calibrated": boolean,
"sample_time_s": _m914_num("s", 0, nullable=True), "synthetic": {"type": "boolean", "const": True}}
measurement_effects = [sid for sid in slots if sid.startswith(("measurement.", "endpoint.stable", "endpoint.elapsed", "temperature.compensation", "display."))]
calibration_effects = [sid for sid in slots if ".calibrat" in sid or sid.startswith("calibration.")]
def cap(inputs, outputs, example, description, effects, observes, preconditions="参数与声明范围匹配。", kind="device_command"):
return {"availability": "implemented", "visibility": "agent", "kind": kind,
"description_zh": description, "input_schema": _m914_object(inputs), "output_schema": _m914_object(outputs),
"example_arguments": [example], "state_effects": [{"state_id": sid, "timing": "immediate", "description_zh": description} for sid in dict.fromkeys(effects)],
"observes": observes, "scene_backend_required": False, "preconditions_zh": preconditions,
"completion_criterion_zh": "同步提交状态;测量与终点只在宿主提供新样本并推进共同时间后更新。"}
caps = {
"power.set": cap({"enabled": boolean}, {"enabled": boolean}, {"enabled": True}, "设置供电;断电停止记录并清除当前读数与终点历史。", ["power.enabled", "acquisition.running"] + measurement_effects, ["power.enabled"]),
"probe.set_installed": cap({"slot": channel, "installed": boolean}, {"slot": channel, "installed": boolean}, {"slot": "ph", "installed": True}, "断电时更换逻辑探头槽;pH与DO共用digital接口且互斥,电导使用独立接口;更换清除该槽校准。", [f"probe.{n}.installed" for n in METROHM914_CHANNELS] + calibration_effects + measurement_effects, [f"probe.{n}.installed" for n in METROHM914_CHANNELS], "供电关闭;安装pH或DO时另一共用digital槽未安装。", "configuration"),
"electrochemistry.select_probe": cap({"slot": channel}, {"slot": channel}, {"slot": "ph"}, "选择已安装的单通道读数配置,切换后重新采样与稳定。", ["probe.selected"] + measurement_effects, ["probe.selected"], "所选槽已安装;未在记录。"),
"electrochemistry.configure_temperature": cap({"mode": {"type": "string", "enum": ["automatic", "manual"]}, "manual_temperature_k": _m914_num("K", nullable=True)}, {"mode": {"type": "string"}, "manual_temperature_k": _m914_num("K", nullable=True)}, {"mode": "automatic", "manual_temperature_k": None}, "自动模式使用宿主样品温度;手动模式必须明确给定正开尔文温度;Nernst及可选电导线性温补均为工程假设。", ["temperature.mode", "temperature.manual_k"] + measurement_effects, ["temperature.mode", "temperature.manual_k"], "未在记录;manual需正有限温度,automatic需null。"),
"electrochemistry.configure_endpoint": cap({"hold_s": _m914_num("s", 0, 3600), "tolerance_fraction": _m914_num("1", 0, 1)}, {"hold_s": _m914_num("s"), "tolerance_fraction": _m914_num("1")}, {"hold_s": 2, "tolerance_fraction": 0.001}, "显式设定稳定窗口与全量程比例阈值;同窗口最大最小值差不超过阈值时为稳定;上限仅为运行层资源边界。", ["endpoint.hold_s", "endpoint.tolerance_fraction"] + measurement_effects, ["endpoint.hold_s", "endpoint.tolerance_fraction"], "未在记录;hold_s必须大于零。"),
"acquisition.set_interval": cap({"interval_s": _m914_num("s", 1, 86400)}, {"interval_s": _m914_num("s")}, {"interval_s": 1}, "记录间隔为1s的整数倍;上限86400s是运行层资源边界,非厂家规格。", ["acquisition.interval_s"], ["acquisition.interval_s"], "未在记录;间隔为整数秒。"),
"electrochemistry.calibrate": cap({"slot": channel, "standard_value": _m914_num("1", -13, 20)}, {"slot": channel, "calibrated": boolean, "synthetic": {"type": "boolean", "const": True}}, {"slot": "ph", "standard_value": 7}, "有界单点合成校准:标准值按slot单位解释(ph=1、conductance=S、do=kg/m3);建立加性偏置修正,不声称厂家校准算法、精度或溯源。", calibration_effects + measurement_effects, [f"probe.{n}.calibrated" for n in METROHM914_CHANNELS], "供电、选中且安装槽、当前新鲜读数稳定、未记录;宿主明确标定匹配槽与已知标准值;标准值在该槽规格范围内。"),
"acquisition.start": cap({}, {"running": boolean}, {}, "开始记录后续实际宿主样本;不补造中间记录或推进时间。", ["acquisition.running"], ["acquisition.running"], "供电、已安装选中槽、已配置终点。"),
"acquisition.stop": cap({}, {"running": boolean}, {}, "停止后保留已记录数据。", ["acquisition.running"], ["acquisition.running"]),
"electrochemistry.reading": cap({}, reading_fields, {}, "返回所选配置的同版本合成读数;不暴露宿主真值,不推进时间。", [], [sid for sid in slots if sid.startswith("measurement.")] + ["endpoint.stable"], kind="query"),
"acquisition.records": cap({}, {"records": {"type": "array", "items": _m914_object(reading_fields)}, "synthetic": {"type": "boolean", "const": True}}, {}, "返回该实例已记录的可观察合成结果(最多1024条,满时停止),不含真值或宿主配置。", [], ["acquisition.record_count"], kind="query"),
}
# Disjoint schemas preserve each standard's SI unit, even though all are numeric.
caps["electrochemistry.calibrate"]["input_schema"] = _m914_object({"slot": channel, "standard_value": {"anyOf": [_m914_num(unit, lo, hi) for lo, hi, unit in METROHM914_CHANNELS.values()]}})
caps["electrochemistry.calibrate"]["input_schema"]["allOf"] = [{"anyOf": [_m914_object({"slot": {"type": "string", "const": n}, "standard_value": _m914_num(unit, lo, hi)}) for n, (lo, hi, unit) in METROHM914_CHANNELS.items()]}]
caps["electrochemistry.configure_endpoint"]["input_schema"]["properties"]["hold_s"]["exclusiveMinimum"] = 0
caps["acquisition.set_interval"]["input_schema"]["properties"]["interval_s"]["multipleOf"] = 1
caps["electrochemistry.configure_temperature"]["input_schema"]["allOf"] = [{"anyOf": [
_m914_object({"mode": {"type": "string", "const": "automatic"}, "manual_temperature_k": {"type": "null"}}),
_m914_object({"mode": {"type": "string", "const": "manual"}, "manual_temperature_k": {"type": "number", "exclusiveMinimum": 0, "x-unit": "K"}})]}]
for name, value in caps.items():
value["binding"] = f"basic40_runtime_measure.Metrohm914Session.invoke(instance_id=..., capability_id='{name}', arguments=..., request_id=...)"
def parameter(value, unit, evidence, source):
return {"value": value, "unit": unit, "evidence": evidence, "source": source}
params = {
"ph_range": parameter([-13, 20], "1", "catalog", "CHEM-005 参数与来源 row10"),
"ph_resolution": parameter(0.001, "1", "catalog", "仅用于显示量化,不是噪声或准确度"),
"ph_instrument_accuracy": parameter(0.003, "1", "catalog", "仪表±0.003、不含探头误差;未用作仿真精度"),
"conductance_range": parameter([1e-7, 0.5], "S", "catalog", "0.1µS..500mS,是电导而非电导率"),
"do_range": parameter([0, 0.05], "kg/m3", "catalog", "0..50mg/L按SI换算"),
"record_base_interval_s": parameter(1, "s", "catalog", "CHEM-005 数据间隔1s"),
"nernst_model": parameter("E=E_ref-ln(10)*R*T/F*(pH-pH_ref); pH_display=pH_ref+(E_ref-E)/(ln(10)*R*T_comp/F)", "1", "engineering_assumption", "理想Nernst响应,R=8.31446261815324 J/(mol K),F=96485.33212331001 C/mol;参考点和温度必须宿主显式提供"),
"endpoint_model": parameter("max(window)-min(window)<=tolerance_fraction*(channel_max-channel_min)", "1", "engineering_assumption", "窗口hold与容差初始null;以宿主给定样本零阶保持,每个实际样本才更新,不推断厂家终点算法"),
"calibration_model": parameter("corrected=raw+(standard-raw_at_calibration)", "1", "engineering_assumption", "单点合成偏置,仅当前安装探头;更换使校准失效"),
"conductance_temperature_model": parameter("G_ref=G/[1+alpha*(T_comp-T_ref)]", "1", "engineering_assumption", "仅当宿主明确给出alpha和T_ref才启用;否则报告原始电导且不声称完成电导温补"),
}
for n, unit in (("cell_constant_m_inv", "1/m"), ("contamination_coefficient", "1"), ("drift_rate", "1/s"), ("probe_mass_kg", "kg"), ("do_temperature_coefficient", "1/K"), ("reference_potential_v", "V"), ("reference_ph", "1"), ("endpoint_hold_s", "s"), ("endpoint_tolerance_fraction", "1"), ("conductance_temperature_coefficient", "1/K")):
params[n] = parameter(None, unit, "unknown", "表未给出;不默认生成数值或用整机参数代替")
return {"asset_types": {METROHM914_TYPE: {"catalog_id": "CHEM-005", "model": "Metrohm | 914 pH/DO/Conductometer", "asset_version": "1.1.0", "state_slots": slots, "capabilities": caps, "parameters": params}},
"host_capabilities": {"sim.host_step": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "Metrohm914Runtime.host_step(time_s, inputs={instance_id: sample})"}},
"limitations": ["All measurement outputs are synthetic and estimated; accuracy ±0.003 is an instrument specification, not simulated accuracy.", "pH and DO share one digital interface and cannot both be installed; conductance is an independent analog interface. Runtime selects one channel at a time; parallel acquisition is not implemented.", "No default cell constant, contamination/drift/noise or probe mass is invented. Conductance is S, not S/m; DO is kg/m3.", "Nernst, optional linear conductance compensation, single-point calibration and stability rules are engineering_assumption; DO temperature/pressure/salinity compensation is absent.", "Readings need explicit host samples; automatic temperature needs explicit host temperature. Missing values stay null. No intermediate samples are fabricated.", "Scene adapter receives only display/power/probe installation state; no robot, contact solver or hardware driver. A failing callback may partly modify the scene but leaves a command's process candidate uncommitted.", "Host-supplied principals enforce API visibility only. Python/process/filesystem sandbox isolation is not implemented.", "Request deduplication is in-memory and does not survive restart."]}
class Metrohm914Runtime:
"""Trusted host with absolute shared time; expose sessions, not this object."""
def __init__(self, *, scene_adapter=None):
self.scene_adapter, self.time_s = scene_adapter, 0.0
self._instances, self._principals, self._requests, self._logs = {}, {}, {}, {}
self._lock = _m914_threading.RLock()
self._metadata = export_metrohm914_contract_metadata()
self.register_principal("__public_agent__", visibility="agent")
self._agent = self.session("__public_agent__")
def create_instance(self, instance_id, asset_type_id=METROHM914_TYPE):
with self._lock:
if not isinstance(instance_id, str) or not instance_id or instance_id in self._instances or asset_type_id != METROHM914_TYPE:
raise ValueError("Unique instance ID and declared type required")
inst = {"revision": 0, "power": False, "selected": "ph", "installed": {n: False for n in METROHM914_CHANNELS},
"calibration": {n: {"calibrated": False, "time": None, "offset": None} for n in METROHM914_CHANNELS},
"temperature_mode": "automatic", "manual_temperature": None, "compensation_temperature": None,
"hold": None, "tolerance": None, "stable": False, "elapsed": 0.0, "history": [],
"interval": 1.0, "running": False, "records": [], "next_record": None,
"truth": {"ph": None, "conductance_s": None, "do_kg_m3": None, "temperature_k": None,
"reference_ph": None, "reference_potential_v": None, "conductance_temp_coefficient_k_inv": None,
"conductance_reference_temperature_k": None, "standard_slot": None, "standard_value": None},
"sample_time": None, "raw": None, "status": "OFF", "readings": {"ph": None, "potential_v": None, "conductance_s": None, "do_kg_m3": None}}
if self.scene_adapter:
self.scene_adapter(instance_id, self._scene(inst))
self._instances[instance_id] = inst
def register_principal(self, principal_id, *, visibility, instance_ids=None):
with self._lock:
if not isinstance(principal_id, str) or not principal_id or principal_id in self._principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Invalid or duplicate trusted identity")
if instance_ids is not None and (not isinstance(instance_ids, (list, tuple, set, frozenset)) or any(not isinstance(x, str) for x in instance_ids)):
raise ValueError("Instance scope must be a string collection")
scope = None if instance_ids is None else frozenset(instance_ids)
if scope is not None and not scope <= self._instances.keys():
raise ValueError("Unknown instance scope")
self._principals[principal_id], self._logs[principal_id] = (visibility, scope), []
def session(self, principal_id):
if principal_id not in self._principals:
raise ValueError("Identity must be registered by trusted host")
return Metrohm914Session(self, principal_id)
def describe(self, **kwargs):
return self._agent.describe(**kwargs)
def read(self, **kwargs):
return self._agent.read(**kwargs)
def invoke(self, **kwargs):
return self._agent.invoke(**kwargs)
def write(self, **kwargs):
return self._agent.write(**kwargs)
def describe_host(self):
return _m914_copy.deepcopy(self._metadata["host_capabilities"])
@staticmethod
def host_template_sample(solution):
"""Trusted host only: complete explicit truth sample (for host_step) built from public standards/pKa data."""
return _m914_template_module().build_sample(solution)["sample"]
def host_step_template(self, time_s, *, solutions, inputs=None):
"""Trusted host only: host_step with template-built samples, then attach their provenance to the instances."""
return _m914_template_module().host_step_template(self, time_s, solutions, inputs)
@staticmethod
def _reset(inst):
inst["stable"], inst["elapsed"], inst["history"], inst["sample_time"], inst["raw"] = False, 0.0, [], None, None
inst["readings"] = {"ph": None, "potential_v": None, "conductance_s": None, "do_kg_m3": None}
inst["compensation_temperature"] = None
inst["status"] = "OFF" if not inst["power"] else "PROBE_MISSING" if not inst["installed"][inst["selected"]] else "NO_SAMPLE"
@staticmethod
def _reading(inst):
return {"slot": inst["selected"], "status": inst["status"], "stable": inst["stable"], **inst["readings"],
"calibrated": inst["calibration"][inst["selected"]]["calibrated"], "sample_time_s": inst["sample_time"], "synthetic": True}
@staticmethod
def _display(inst):
r = Metrohm914Runtime._reading(inst)
key = {"ph": "ph", "conductance": "conductance_s", "do": "do_kg_m3"}[inst["selected"]]
value = r[key]
unit = METROHM914_CHANNELS[inst["selected"]][2]
return f"{inst['selected'].upper()} {'---' if value is None else format(value, '.6g')} {unit} | {inst['status']} | SYNTHETIC"
@staticmethod
def _scene(inst):
return {"power.enabled": inst["power"], "probe.selected": inst["selected"], "display.text": Metrohm914Runtime._display(inst),
**{f"probe.{n}.installed": v for n, v in inst["installed"].items()}}
@staticmethod
def _values(inst):
v = {"power.enabled": inst["power"], "probe.selected": inst["selected"], "temperature.mode": inst["temperature_mode"],
"temperature.manual_k": inst["manual_temperature"], "temperature.compensation_k": inst["compensation_temperature"],
"endpoint.hold_s": inst["hold"], "endpoint.tolerance_fraction": inst["tolerance"], "endpoint.stable": inst["stable"],
"endpoint.elapsed_s": inst["elapsed"], "acquisition.interval_s": inst["interval"], "acquisition.running": inst["running"],
"acquisition.record_count": len(inst["records"]), "measurement.status": inst["status"], "measurement.synthetic": True,
"measurement.sample_time_s": inst["sample_time"], "display.text": Metrohm914Runtime._display(inst)}
v.update({f"measurement.{k}": value for k, value in inst["readings"].items()})
for n in METROHM914_CHANNELS:
v[f"probe.{n}.installed"], v[f"probe.{n}.calibrated"], v[f"probe.{n}.calibration_time_s"] = inst["installed"][n], inst["calibration"][n]["calibrated"], inst["calibration"][n]["time"]
v[f"calibration.{n}.offset"] = inst["calibration"][n]["offset"]
v.update({f"truth.{key}": value for key, value in inst["truth"].items() if key != "standard_value"})
for name, suffix in (("ph", "ph"), ("conductance", "conductance_s"), ("do", "do_kg_m3")):
v[f"truth.standard_{suffix}"] = inst["truth"]["standard_value"] if inst["truth"]["standard_slot"] == name else None
return v
def debug_snapshot(self):
with self._lock:
return {"time_s": self.time_s, "instances": {n: {"revision": i["revision"], "state": self._values(i), "internal": _m914_copy.deepcopy(i)} for n, i in self._instances.items()}}
def _sample(self, inst, time_s, sample):
# Each mapping is a complete explicit sample. Omitted fields are unknown.
inst["truth"] = {k: sample.get(k) for k in inst["truth"]}
self._reset(inst)
if not inst["power"] or not inst["installed"][inst["selected"]]:
return
truth, name = inst["truth"], inst["selected"]
value = truth[{"ph": "ph", "conductance": "conductance_s", "do": "do_kg_m3"}[name]]
if value is None:
return
inst["sample_time"] = time_s
comp_t = truth["temperature_k"] if inst["temperature_mode"] == "automatic" else inst["manual_temperature"]
inst["compensation_temperature"] = comp_t
raw, potential = value, None
if name == "ph":
if any(v is None for v in (comp_t, truth["temperature_k"], truth["reference_ph"], truth["reference_potential_v"])):
inst["status"] = "MISSING_CONFIGURATION"
return
factor = _m914_math.log(10) * 8.31446261815324 / 96485.33212331001
potential = truth["reference_potential_v"] - factor * truth["temperature_k"] * (value - truth["reference_ph"])
raw = truth["reference_ph"] + (truth["temperature_k"] / comp_t) * (value - truth["reference_ph"])
elif name == "conductance":
alpha, reference_t = truth["conductance_temp_coefficient_k_inv"], truth["conductance_reference_temperature_k"]
if alpha is not None or reference_t is not None:
if alpha is None or reference_t is None or comp_t is None:
inst["status"] = "MISSING_CONFIGURATION"
return
denominator = 1 + alpha * (comp_t - reference_t)
if not _m914_number(denominator) or denominator <= 0:
raise ValueError("Invalid explicit conductance compensation configuration")
raw = value / denominator
if not _m914_number(raw) or (potential is not None and not _m914_number(potential)):
raise ValueError("Nonfinite synthetic calculation")
inst["raw"] = raw
offset = inst["calibration"][name]["offset"]
measured = raw if offset is None else raw + offset
lo, hi, _ = METROHM914_CHANNELS[name]
if not _m914_number(measured) or not lo <= measured <= hi:
inst["status"] = "OUT_OF_RANGE"
return
if name == "ph":
measured = float(_m914_Decimal(str(measured)).quantize(_m914_Decimal("0.001"), rounding=_m914_ROUND_HALF_UP))
inst["readings"][{"ph": "ph", "conductance": "conductance_s", "do": "do_kg_m3"}[name]] = measured
inst["readings"]["potential_v"] = potential
inst["status"] = "UNSTABLE"
def host_step(self, time_s, *, inputs=None):
"""One absolute external time, with no hidden integration or backfill.
Each supplied sample replaces its full truth record; omitted fields become
null. Omitted instances keep last reading marked stale. Repeated time is a
pure no-op only with no inputs; new samples require strictly greater time.
All validation/calculation precedes process commit. Callback failures after
host commit cannot roll back the shared world's elapsed time.
"""
samples = {} if inputs is None else inputs
with self._lock:
if not _m914_number(time_s) or time_s < self.time_s or not isinstance(samples, dict) or any(not isinstance(n, str) or n not in self._instances or not isinstance(s, dict) for n, s in samples.items()):
raise ValueError("Finite monotonic common time and declared instance sample mapping required")
if time_s == self.time_s:
if samples:
raise ValueError("New samples require increasing common time")
return
allowed = set(next(iter(self._instances.values()))["truth"]) if self._instances else set()
for sample in samples.values():
if set(sample) - allowed:
raise ValueError("Unknown host sample field")
for key, value in sample.items():
if key == "standard_slot":
if value is not None and (not isinstance(value, str) or value not in METROHM914_CHANNELS):
raise ValueError("Unknown standard channel")
elif value is not None and not _m914_number(value):
raise ValueError("Host sample values must be finite numbers or null")
elif key.endswith("temperature_k") and value is not None and value <= 0:
raise ValueError("Temperature must be positive kelvin")
standard_slot, standard = sample.get("standard_slot"), sample.get("standard_value")
if (standard_slot is None) != (standard is None):
raise ValueError("Standard channel and explicit known value are a pair")
if standard_slot is not None and not METROHM914_CHANNELS[standard_slot][0] <= standard <= METROHM914_CHANNELS[standard_slot][1]:
raise ValueError("Synthetic standard is outside declared channel range")
candidates = _m914_copy.deepcopy(self._instances)
for n, inst in candidates.items():
if n in samples:
old_history = inst["history"]
self._sample(inst, float(time_s), samples[n])
if inst["status"] == "UNSTABLE" and inst["hold"] is not None:
value = inst["readings"][{"ph": "ph", "conductance": "conductance_s", "do": "do_kg_m3"}[inst["selected"]]]
history = old_history + [(float(time_s), value)]
cutoff = time_s - inst["hold"]
while len(history) > 1 and history[1][0] <= cutoff:
history.pop(0)
inst["history"] = history
span = METROHM914_CHANNELS[inst["selected"]][1] - METROHM914_CHANNELS[inst["selected"]][0]
inside = max(v for _, v in history) - min(v for _, v in history) <= inst["tolerance"] * span
inst["elapsed"] = min(inst["hold"], time_s - history[0][0]) if inside else 0.0
inst["stable"] = bool(inside and time_s - history[0][0] >= inst["hold"])
inst["status"] = "STABLE" if inst["stable"] else "UNSTABLE"
if inst["running"] and inst["status"] in ("UNSTABLE", "STABLE") and time_s >= inst["next_record"]:
inst["records"].append(self._reading(inst))
inst["next_record"] = float(time_s) + inst["interval"]
if len(inst["records"]) >= 1024:
inst["running"] = False
elif inst["sample_time"] is not None:
inst["stable"], inst["elapsed"], inst["history"], inst["status"] = False, 0.0, [], "STALE"
inst["revision"] += 1
self._instances, self.time_s = candidates, float(time_s)
if self.scene_adapter:
failed = False
for n, inst in candidates.items():
try:
self.scene_adapter(n, self._scene(inst))
except Exception:
failed = True
if failed:
raise RuntimeError("Host process/time committed; scene callback synchronization failed") from None
class Metrohm914Session:
"""Filtered API boundary. Python object privacy is not a security sandbox."""
def __init__(self, host, principal_id):
self.__host, self.__principal = host, principal_id
def _visible(self, slot):
return slot["visibility"] == "agent" or self.__host._principals[self.__principal][0] in ("debug", "evaluator")
def _instance(self, instance_id):
if not isinstance(instance_id, str):
return None
_, scope = self.__host._principals[self.__principal]
return self.__host._instances.get(instance_id) if scope is None or instance_id in scope else None
def _envelope(self, instance_id, request_id=None, *, result=None, observations=None, status="succeeded", error=None):
inst = self._instance(instance_id)
return {"protocol_version": "1.0.0", "instance_id": instance_id if isinstance(instance_id, str) else None,
"request_id": request_id if isinstance(request_id, str) else None, "operation_id": None, "status": status,
"state_revision": inst["revision"] if inst else None, "clock": {"domain": "simulation", "time_s": self.__host.time_s},
"result": _m914_copy.deepcopy(result or {}), "observations": _m914_copy.deepcopy(observations or {}), "error": error}
def _error(self, instance_id, code, request_id=None, status="rejected"):
messages = {"UNKNOWN_INSTANCE": "Instance unavailable to this session.", "UNKNOWN_CAPABILITY": "Capability unavailable.",
"INVALID_ARGUMENT": "Arguments do not match schema or bounded configuration.", "ACCESS_DENIED": "Request is outside session access policy.",
"PRECONDITION_FAILED": "Required operating state, calibration fixture or configuration unavailable.",
"REQUEST_CONFLICT": "Request ID already belongs to different arguments.", "DEVICE_ERROR": "Scene synchronization did not complete."}
return self._envelope(instance_id, request_id, status=status, error={"code": code, "message": messages[code], "retryable": False,
"side_effects": "unknown" if code == "DEVICE_ERROR" else "none", "progress": None})
def describe(self, *, asset_type_id=None, instance_id=None):
with self.__host._lock:
if (asset_type_id is None) == (instance_id is None) or (asset_type_id is not None and asset_type_id != METROHM914_TYPE):
return self._error(None, "INVALID_ARGUMENT")
if instance_id is not None and self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
_, scope = self.__host._principals[self.__principal]
if scope is not None and not scope:
return self._error(instance_id, "ACCESS_DENIED")
spec = _m914_copy.deepcopy(self.__host._metadata["asset_types"][METROHM914_TYPE])
spec["state_slots"] = {n: s for n, s in spec["state_slots"].items() if self._visible(s)}
spec["capabilities"].update(_m914_template_module().capability_metadata()) # additive public-data extension
for cap in spec["capabilities"].values():
cap["state_effects"] = [e for e in cap["state_effects"] if e["state_id"] in spec["state_slots"]]
cap["observes"] = [n for n in cap["observes"] if n in spec["state_slots"]]
return {"protocol_version": "1.0.0", "asset_type_id": METROHM914_TYPE, "instance_id": instance_id,
"adapter": "basic40_runtime_measure.Metrohm914Session", **spec, "limitations": _m914_copy.deepcopy(self.__host._metadata["limitations"])}
def read(self, *, instance_id, state_ids=None):
with self.__host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
slots = self.__host._metadata["asset_types"][METROHM914_TYPE]["state_slots"]
if state_ids is None:
state_ids = [n for n, s in slots.items() if self._visible(s)]
if not isinstance(state_ids, list) or any(not isinstance(n, str) for n in state_ids) or len(state_ids) != len(set(state_ids)):
return self._error(instance_id, "INVALID_ARGUMENT")
if any(n not in slots or not self._visible(slots[n]) for n in state_ids):
return self._error(instance_id, "ACCESS_DENIED")
values = self.__host._values(inst)
observations = {}
for n in state_ids:
derived = slots[n]["origin"] == "derived"
stale = inst["status"] == "STALE" and n.startswith(("measurement.", "temperature.compensation")) and n not in ("measurement.status", "measurement.synthetic")
observations[n] = {"value": values[n], "unit": slots[n]["unit"], "quality": "unavailable" if values[n] is None else "stale" if stale else "estimated" if derived else "valid",
"sample_time_s": inst["sample_time"] if n.startswith(("measurement.", "truth.", "temperature.compensation")) else self.__host.time_s,
"sample_window_s": None, "reason": "No explicit sample/configuration or this output is not selected." if values[n] is None else "No new host sample at current time." if stale else None,
"synthetic": derived}
return self._envelope(instance_id, observations=observations)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
if not isinstance(capability_id, str) or not isinstance(arguments, dict) or not isinstance(request_id, str) or not request_id or len(request_id) > 256:
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
try:
digest = _m914_hashlib.sha256(_m914_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False).encode()).hexdigest()
except (ValueError, TypeError, OverflowError):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
key = self.__principal, instance_id, request_id
if key in host._requests:
previous, response = host._requests[key]
return _m914_copy.deepcopy(response) if previous == digest else self._error(instance_id, "REQUEST_CONFLICT", request_id)
response = self._checked(instance_id, inst, capability_id, arguments, request_id)
host._requests[key] = digest, _m914_copy.deepcopy(response)
host._logs[self.__principal].append({"instance_id": instance_id, "capability_id": capability_id, "request_id": request_id, "response": _m914_copy.deepcopy(response)})
return response
def _checked(self, instance_id, inst, cap, args, request_id):
host = self.__host
if cap in METROHM914_TEMPLATE_CAPABILITIES: # additive public-data extension; legacy capabilities unchanged
return _m914_template_module().invoke(self, host, instance_id, inst, cap, args, request_id,
evaluator=self._visible({"visibility": "debug"}))
fail = lambda code, status="rejected": self._error(instance_id, code, request_id, status)
definitions = host._metadata["asset_types"][METROHM914_TYPE]["capabilities"]
if cap not in definitions:
return fail("UNKNOWN_CAPABILITY")
expected = {"power.set": {"enabled"}, "probe.set_installed": {"slot", "installed"}, "electrochemistry.select_probe": {"slot"},
"electrochemistry.configure_temperature": {"mode", "manual_temperature_k"}, "electrochemistry.configure_endpoint": {"hold_s", "tolerance_fraction"},
"acquisition.set_interval": {"interval_s"}, "electrochemistry.calibrate": {"slot", "standard_value"}}.get(cap, set())
if set(args) != expected:
return fail("INVALID_ARGUMENT")
if "slot" in args and (not isinstance(args["slot"], str) or args["slot"] not in METROHM914_CHANNELS):
return fail("INVALID_ARGUMENT")
if any(type(args[n]) is not bool for n in ("enabled", "installed") if n in args):
return fail("INVALID_ARGUMENT")
if cap == "electrochemistry.configure_temperature":
t = args["manual_temperature_k"]
if args["mode"] not in ("automatic", "manual") or (args["mode"] == "automatic" and t is not None) or (args["mode"] == "manual" and (not _m914_number(t) or t <= 0)):
return fail("INVALID_ARGUMENT")
if cap == "electrochemistry.configure_endpoint" and (not _m914_number(args["hold_s"]) or not 0 < args["hold_s"] <= 3600 or not _m914_number(args["tolerance_fraction"]) or not 0 <= args["tolerance_fraction"] <= 1):
return fail("INVALID_ARGUMENT")
if cap == "acquisition.set_interval" and (not _m914_number(args["interval_s"]) or not 1 <= args["interval_s"] <= 86400 or args["interval_s"] != int(args["interval_s"])):
return fail("INVALID_ARGUMENT")
if cap == "electrochemistry.calibrate":
lo, hi, _ = METROHM914_CHANNELS[args["slot"]]
if not _m914_number(args["standard_value"]) or not lo <= args["standard_value"] <= hi:
return fail("INVALID_ARGUMENT")
if cap == "probe.set_installed":
other = {"ph": "do", "do": "ph"}.get(args["slot"])
if inst["power"] or (args["installed"] and other and inst["installed"][other]):
return fail("PRECONDITION_FAILED")
if cap == "electrochemistry.select_probe" and (not inst["installed"][args["slot"]] or inst["running"]):
return fail("PRECONDITION_FAILED")
if cap in ("electrochemistry.configure_temperature", "electrochemistry.configure_endpoint", "acquisition.set_interval") and inst["running"]:
return fail("PRECONDITION_FAILED")
if cap == "electrochemistry.calibrate" and (inst["running"] or not inst["power"] or not inst["stable"] or inst["sample_time"] != host.time_s or inst["selected"] != args["slot"] or not inst["installed"][args["slot"]] or inst["truth"]["standard_slot"] != args["slot"] or inst["truth"]["standard_value"] != args["standard_value"]):
return fail("PRECONDITION_FAILED")
if cap == "acquisition.start" and (not inst["power"] or not inst["installed"][inst["selected"]] or inst["hold"] is None or len(inst["records"]) >= 1024):
return fail("PRECONDITION_FAILED")
if cap == "electrochemistry.reading":
return self._envelope(instance_id, request_id, result=host._reading(inst))
if cap == "acquisition.records":
return self._envelope(instance_id, request_id, result={"records": inst["records"], "synthetic": True})
candidate = _m914_copy.deepcopy(inst)
if cap == "power.set":
if candidate["power"] != args["enabled"]:
candidate["power"] = args["enabled"]
if not args["enabled"]:
candidate["running"] = False
host._reset(candidate)
result = {"enabled": candidate["power"]}
elif cap == "probe.set_installed":
n = args["slot"]
if candidate["installed"][n] != args["installed"]:
candidate["installed"][n] = args["installed"]
candidate["calibration"][n] = {"calibrated": False, "time": None, "offset": None}
host._reset(candidate)
result = {"slot": n, "installed": args["installed"]}
elif cap == "electrochemistry.select_probe":
if candidate["selected"] != args["slot"]:
candidate["selected"] = args["slot"]
host._reset(candidate)
result = {"slot": args["slot"]}
elif cap == "electrochemistry.configure_temperature":
candidate["temperature_mode"], candidate["manual_temperature"] = args["mode"], args["manual_temperature_k"]
host._reset(candidate)
result = dict(args)
elif cap == "electrochemistry.configure_endpoint":
candidate["hold"], candidate["tolerance"] = float(args["hold_s"]), float(args["tolerance_fraction"])
host._reset(candidate)
result = dict(args)
elif cap == "acquisition.set_interval":
candidate["interval"] = float(args["interval_s"])
result = dict(args)
elif cap == "electrochemistry.calibrate":
candidate["calibration"][args["slot"]] = {"calibrated": True, "time": host.time_s, "offset": float(args["standard_value"]) - candidate["raw"]}
host._reset(candidate)
result = {"slot": args["slot"], "calibrated": True, "synthetic": True}
else:
candidate["running"] = cap == "acquisition.start"
if candidate["running"] and not inst["running"]:
candidate["next_record"] = host.time_s + candidate["interval"]
result = {"running": candidate["running"]}
if host.scene_adapter and host._scene(candidate) != host._scene(inst):
try:
host.scene_adapter(instance_id, host._scene(candidate))
except Exception:
return fail("DEVICE_ERROR", "failed")
candidate["revision"] += 1
host._instances[instance_id] = candidate
return self._envelope(instance_id, request_id, result=result)
def write(self, *, instance_id, state_id, value, request_id):
with self.__host._lock:
if self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
slots = self.__host._metadata["asset_types"][METROHM914_TYPE]["state_slots"]
if not isinstance(state_id, str) or state_id not in slots or not self._visible(slots[state_id]) or slots[state_id]["write_via"] is None:
return self._error(instance_id, "ACCESS_DENIED", request_id)
route = slots[state_id]["write_via"]
return self.invoke(instance_id=instance_id, capability_id=route["capability_id"], arguments={**route["fixed_arguments"], route["parameter"]: value}, request_id=request_id)
def logs(self):
with self.__host._lock:
return _m914_copy.deepcopy(self.__host._logs[self.__principal])
def write_metrohm914_runtime_reports(output_directory):
import datetime
import importlib.util
import io
import pathlib
import platform
import unittest
root = pathlib.Path(__file__).resolve().parents[1]
spec = importlib.util.spec_from_file_location("test_basic40_measure_metrohm914", root / "tests/test_basic40_measure.py")
module = importlib.util.module_from_spec(spec)
spec.loader.exec_module(module)
suite = unittest.defaultTestLoader.loadTestsFromTestCase(module.Metrohm914RuntimeTests)
stream = io.StringIO()
result = unittest.TextTestRunner(stream=stream, verbosity=2).run(suite)
metadata = export_metrohm914_contract_metadata()
report = {"catalog_id": "CHEM-005", "recorded_at": datetime.datetime.now(datetime.timezone.utc).isoformat(),
"environment": {"python": platform.python_version(), "platform": platform.platform()},
"method": "unittest explicit synthetic host samples; all capability outputs/state effects; common external timestamp; three slot calibration; Nernst and SI boundaries; rejection atomicity; identities, deduplication and scene callback failure",
"tests_run": result.testsRun, "failures": len(result.failures), "errors": len(result.errors), "result": "passed" if result.wasSuccessful() else "failed",
"capabilities_verified": sorted(metadata["asset_types"][METROHM914_TYPE]["capabilities"]) if result.wasSuccessful() else [],
"output": stream.getvalue(), "not_run": ["real_hardware", "robot_execution", "contact_solver", "process_filesystem_security_isolation", "parallel_channel_acquisition", "manufacturer_calibration_accuracy", "do_temperature_pressure_salinity_compensation"],
"scene_scope": "Only a recording/failing callback is tested here; evaluated Blender geometry requires the separate scene verification record.",
"synthetic": True}
directory = pathlib.Path(output_directory)
directory.mkdir(parents=True, exist_ok=True)
for name, value in (("runtime_validation.json", report), ("runtime_metadata.json", metadata)):
(directory / name).write_text(_m914_json.dumps(value, ensure_ascii=False, indent=2) + "\n", encoding="utf-8")
return report
# END CHEM-005 METROHM 914 APPEND-ONLY RUNTIME
# BEGIN CHEM-102 METROHM 899 APPEND-ONLY RUNTIME
# All _kf899 names and classes in this block are independent of earlier assets.
import copy as _kf899_copy
import json as _kf899_json
import math as _kf899_math
import threading as _kf899_threading
METROHM899_TYPE = "instrument.metrohm_899"
KF899_FARADAY_C_MOL = 96485.33212331001
KF899_WATER_MOLAR_MASS_KG_MOL = 0.01801528
KF899_KG_PER_COULOMB = KF899_WATER_MOLAR_MASS_KG_MOL / (2 * KF899_FARADAY_C_MOL)
KF899_START_DRIFT_MIN_KG_S = 1e-9 / 60
KF899_START_DRIFT_MAX_KG_S = 999e-9 / 60
METROHM899_TEMPLATE_CAPABILITIES = ("template.list", "template.read", "coulometry.template_report")
def _kf899_template_module():
"""Lazy import of the public-data template extension (scripts/basic40_templates/metrohm_899.py)."""
try:
from .basic40_templates import metrohm_899 as module
except ImportError:
from basic40_templates import metrohm_899 as module
return module
def _kf899_number(value):
try:
return type(value) in (float, int) and _kf899_math.isfinite(value)
except (ValueError, TypeError, OverflowError):
return False
def _kf899_num(unit, lo=None, hi=None, nullable=False):
result = {"type": "number", "x-unit": unit}
if lo is not None:
result["minimum"] = lo
if hi is not None:
result["maximum"] = hi
return {"anyOf": [result, {"type": "null"}]} if nullable else result
def _kf899_object(properties, required=None):
return {"type": "object", "properties": properties,
"required": list(properties) if required is None else required, "additionalProperties": False}
def export_metrohm899_contract_metadata():
"""Type-only authoring metadata. Contains no live instance/sample truth.
This is a synthetic SI model, not Metrohm firmware. F and molecular mass
support an ideal two-electron/water stoichiometric engineering assumption;
precision, noise, current efficiency and electrode transfer functions are
unknown. Host identities and truth are protected at API boundaries only,
not from Python introspection or shared filesystem access.
"""
boolean = {"type": "boolean"}
enum_slot = {"type": "string", "enum": ["cell", "generator", "indicator"]}
current = {"type": "number", "enum": [0.1, 0.2, 0.4], "x-unit": "A"}
config = {
"current_a": current,
"drift_compensation_kg_s": _kf899_num("kg/s", 0, nullable=True),
"start_drift_threshold_kg_s": _kf899_num("kg/s", KF899_START_DRIFT_MIN_KG_S, KF899_START_DRIFT_MAX_KG_S),
"extraction_time_s": _kf899_num("s", 0, 999999),
"stirring_level": {"type": "integer", "minimum": -15, "maximum": 15, "x-unit": "1"},
"sample_mass_kg": _kf899_num("kg", 0, nullable=True),
"endpoint_hold_s": _kf899_num("s", 0, nullable=True),
}
routes = {name: {"capability_id": "coulometry.configure", "parameter": name, "fixed_arguments": {}} for name in config}
def slot(unit, origin, value_schema, visibility="agent", route=None, integral=False):
return {"unit": unit, "origin": origin, "value_schema": value_schema, "visibility": visibility,
"access": "read_write" if route else "read_only", "write_via": route,
"read_binding": "Metrohm899Session.read(instance_id=..., state_ids=[state_id])",
"reference_conditions": None,
"sampling": {"mode": "integral" if integral else "instant", "time_domain": "simulation",
"window": "自本次 coulometry.start 至当前或停止时刻" if integral else None}}
state = {
"power.enabled": slot("1", "setpoint", boolean, route={"capability_id": "power.set", "parameter": "enabled", "fixed_arguments": {}}),
"coulometry.running": slot("1", "derived", boolean),
"coulometry.status": slot("1", "derived", {"type": "string", "enum": ["OFF", "IDLE", "READY", "EXTRACTING", "TITRATING", "HOLDING", "COMPLETED", "STOPPED"]}),
"sample.present": slot("1", "scene", boolean),
"reagent.ready": slot("1", "scene", boolean),
"measurement.elapsed_s": slot("s", "derived", _kf899_num("s", 0)),
"measurement.charge_c": slot("C", "derived", _kf899_num("C", 0), integral=True),
"measurement.water_mass_kg": slot("kg", "derived", _kf899_num("kg", 0, nullable=True), integral=True),
"measurement.water_fraction": slot("1", "derived", _kf899_num("1", 0, nullable=True)),
"measurement.drift_kg_s": slot("kg/s", "derived", _kf899_num("kg/s", 0, nullable=True)),
"measurement.synthetic": slot("1", "derived", {"type": "boolean", "const": True}),
"measurement.sample_time_s": slot("s", "derived", _kf899_num("s", 0, nullable=True)),
"endpoint.hold_elapsed_s": slot("s", "derived", _kf899_num("s", 0)),
"truth.water_remaining_kg": slot("kg", "process_truth", _kf899_num("kg", 0, nullable=True), "debug"),
"truth.sample_water_kg": slot("kg", "process_truth", _kf899_num("kg", 0, nullable=True), "debug"),
"truth.background_drift_kg_s": slot("kg/s", "process_truth", _kf899_num("kg/s", 0, nullable=True), "debug"),
}
for name, spec in config.items():
state["settings." + name] = slot({"current_a": "A", "drift_compensation_kg_s": "kg/s", "start_drift_threshold_kg_s": "kg/s", "extraction_time_s": "s", "stirring_level": "1", "sample_mass_kg": "kg", "endpoint_hold_s": "s"}[name], "setpoint", spec, route=routes[name])
for name in ("cell", "generator", "indicator"):
state[f"slot.{name}.installed"] = slot("1", "scene", boolean, route={"capability_id": "slot.set_installed", "parameter": "installed", "fixed_arguments": {"slot": name}})
reading = {"status": state["coulometry.status"]["value_schema"], "running": boolean,
"elapsed_s": _kf899_num("s", 0), "charge_c": _kf899_num("C", 0),
"water_mass_kg": _kf899_num("kg", 0, nullable=True), "water_fraction": _kf899_num("1", 0, nullable=True),
"drift_kg_s": _kf899_num("kg/s", 0, nullable=True), "synthetic": {"type": "boolean", "const": True}}
result_states = ["coulometry.running", "coulometry.status", "measurement.elapsed_s", "measurement.charge_c",
"measurement.water_mass_kg", "measurement.water_fraction", "measurement.sample_time_s", "endpoint.hold_elapsed_s"]
defs = {
"power.set": ({"enabled": boolean}, {"enabled": boolean}, {"enabled": True}, ["power.enabled", "coulometry.running", "coulometry.status"], ["power.enabled"], "设置供电;断电停止运行并保留已发生的积分结果。", "device_command"),
"slot.set_installed": ({"slot": enum_slot, "installed": boolean}, {"slot": enum_slot, "installed": boolean}, {"slot": "cell", "installed": True}, [f"slot.{x}.installed" for x in ("cell", "generator", "indicator")], [f"slot.{x}.installed" for x in ("cell", "generator", "indicator")], "在关机闲置时声明滴定池或电极的场景装配槽位;不是机器人装卸。", "configuration"),
"coulometry.configure": (config, config, {"current_a": 0.2, "drift_compensation_kg_s": 0, "endpoint_hold_s": 1}, ["settings." + x for x in config], ["settings." + x for x in config], "配置手动发生电流、漂移补偿、启动漂移、萃取时间、搅拌档位、样品质量及假设终点保持时间;至少一个字段。", "configuration"),
"coulometry.start": ({}, reading, {}, result_states + ["truth.water_remaining_kg"], list(s for s in state if s.startswith("measurement.") or s.startswith("coulometry.")), "由已装配、具备试剂且漂移满足阈值的状态启动合成库仑过程;重置当前测量积分。", "device_command"),
"coulometry.stop": ({}, reading, {}, ["coulometry.running", "coulometry.status"], list(s for s in state if s.startswith("measurement.") or s.startswith("coulometry.")), "停止并保留部分电荷、漂移补偿结果与曲线。", "device_command"),
"coulometry.reading": ({}, reading, {}, [], list(s for s in state if s.startswith("measurement.") or s.startswith("coulometry.")), "返回合成可观测结果;不推进宿主时间。", "query"),
"coulometry.curve": ({}, {"records": {"type": "array", "items": _kf899_object({**reading, "sample_time_s": _kf899_num("s", 0)})}, "synthetic": {"type": "boolean", "const": True}}, {}, [], list(s for s in state if s.startswith("measurement.") or s.startswith("coulometry.")), "返回实际宿主步进时刻采样的合成滴定曲线,不插值补造采样。", "query"),
}
capabilities = {}
for name, (args, result, example, effects, observes, meaning, kind) in defs.items():
capabilities[name] = {"input_schema": _kf899_object(args, [] if name == "coulometry.configure" else None),
"output_schema": _kf899_object(result), "example_arguments": [example], "meaning_zh": meaning,
"kind": kind, "visibility": "agent", "availability": "implemented",
"state_effects": [{"state_id": sid, "meaning_zh": "由此调用更新;停止保留既有累计量。", "timing": "immediate"} for sid in effects],
"observes": observes,
"binding": {"backend": "python", "artifact_id": "runtime", "invocation": f"Metrohm899Session.invoke(instance_id=..., capability_id='{name}', arguments=..., request_id=...)"}}
return {"asset_type_id": METROHM899_TYPE, "catalog_id": "CHEM-102", "asset_version": "1.1.0", "state_slots": state,
"capabilities": capabilities, "scene_callback_keys": ["power.enabled", "coulometry.running", "display.text"] + [f"slot.{x}.installed" for x in ("cell", "generator", "indicator")],
"host_capabilities": {
"sim.load_sample": {"invocation": "Metrohm899Host.load_sample(instance_id=..., water_mass_kg=..., background_drift_kg_s=..., reagent_ready=True, request_id=...)", "visibility": "trusted_host_only", "meaning_zh": "初始化合成样品场景;不是物质转移或真实仪器进样。"},
"sim.step": {"invocation": "Metrohm899Host.step(dt_s)", "visibility": "trusted_host_only", "meaning_zh": "校验全部实例后,以公共世界时钟计算电荷、耗水、漂移和理想终点。"}},
"parameters": {
"current_choices_a": {"value": [0.1, 0.2, 0.4], "unit": "A", "evidence": "public_document", "source": "CHEM-102 参数与来源第107行;自动电流策略未实现"},
"initial_current_a": {"value": 0.1, "unit": "A", "evidence": "engineering_assumption", "source": "合成初始设定,不宣称厂家默认"},
"initial_extraction_time_s": {"value": 0.0, "unit": "s", "evidence": "engineering_assumption", "source": "合成初始设定;合法范围 0–999999 s"},
"start_drift_default_kg_s": {"value": 20e-9 / 60, "unit": "kg/s", "evidence": "public_document", "source": "CHEM-102 参数与来源第107行;20 µg/min"},
"faraday_c_mol": {"value": KF899_FARADAY_C_MOL, "unit": "C/mol", "evidence": "engineering_assumption", "source": "理想两电子库仑换算参数;不是厂家整机或部件测量"},
"water_molar_mass_kg_mol": {"value": KF899_WATER_MOLAR_MASS_KG_MOL, "unit": "kg/mol", "evidence": "engineering_assumption", "source": "约定水摩尔质量用于合成化学计量"},
"electrode_response_s": {"value": None, "unit": "s", "evidence": "unknown", "source": "缺实测响应"},
"current_efficiency": {"value": None, "unit": "1", "evidence": "unknown", "source": "未知真实电流效率;模型明确使用理想100%假设"},
"endpoint_hold_s": {"value": None, "unit": "s", "evidence": "unknown", "source": "由仿真任务显式配置,不套用厂家终点默认"},
"cell_capacity_m3": {"value": None, "unit": "m3", "evidence": "unknown", "source": "不得从照片推断容量"}},
"equations": ["Q = integral(I_effective dt)", "m_generated = Q*M_H2O/(2*F)", "m_indicated=max(0,m_generated-drift_compensation_kg_s*elapsed_s)", "water_fraction=m_indicated/sample_mass_kg (null when sample_mass_kg unknown)"],
"boundaries": ["All results synthetic; ideal stoichiometry, 100% modeled current efficiency and ideal depletion endpoint are engineering_assumption.", "Manual 100/200/400 mA only; automatic current firmware, reagent chemistry, electrode potential endpoint, noise, accuracy, hardware and robots not implemented.", "Stirring level is a setting only; no hydrodynamics or invented speed map. Cell capacity and component parameters stay null.", "API truth filtering is not a Python/filesystem sandbox. Keep trusted host and sample fixtures in a separate process for untrusted agents.", "Optional scene callback must be synchronous and atomic; callback tests do not prove evaluated Blender pose or contact physics."]}
class Metrohm899Host:
"""Trusted synthetic world. Only this object supplies truth or advances time."""
def __init__(self, scene_adapter=None):
self.scene_adapter = scene_adapter
self.time_s = 0.0
self._kf899_instances = {}
self._kf899_principals = {}
self._kf899_requests = {}
self._kf899_host_requests = {}
self._kf899_logs = []
self._kf899_lock = _kf899_threading.RLock()
def create_instance(self, instance_id):
with self._kf899_lock:
if not isinstance(instance_id, str) or not instance_id or instance_id in self._kf899_instances:
raise ValueError("A unique nonempty instance_id is required")
state = {"power.enabled": False, "coulometry.running": False, "coulometry.status": "OFF",
"sample.present": False, "reagent.ready": False, "measurement.elapsed_s": 0.0,
"measurement.charge_c": 0.0, "measurement.water_mass_kg": None, "measurement.water_fraction": None,
"measurement.drift_kg_s": None, "measurement.synthetic": True, "measurement.sample_time_s": None,
"endpoint.hold_elapsed_s": 0.0, "truth.water_remaining_kg": None, "truth.sample_water_kg": None,
"truth.background_drift_kg_s": None, "settings.current_a": 0.1,
"settings.drift_compensation_kg_s": None, "settings.start_drift_threshold_kg_s": 20e-9 / 60,
"settings.extraction_time_s": 0.0, "settings.stirring_level": 8, "settings.sample_mass_kg": None,
"settings.endpoint_hold_s": None,
**{f"slot.{x}.installed": False for x in ("cell", "generator", "indicator")}}
self._kf899_instances[instance_id] = {"state": state, "revision": 0, "curve": []}
return instance_id
def register_principal(self, principal_id, *, visibility="agent", instance_ids=None):
with self._kf899_lock:
if not isinstance(principal_id, str) or not principal_id or principal_id in self._kf899_principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Unique principal and host-assigned visibility required")
ids = set(self._kf899_instances if instance_ids is None else instance_ids)
if not ids <= set(self._kf899_instances):
raise ValueError("Unknown instance in policy")
self._kf899_principals[principal_id] = {"visibility": visibility, "instances": ids}
def session(self, principal_id):
if principal_id not in self._kf899_principals:
raise ValueError("Unregistered principal")
return Metrohm899Session(self, principal_id)
def debug_snapshot(self):
with self._kf899_lock:
return _kf899_copy.deepcopy({"time_s": self.time_s, "instances": self._kf899_instances})
def _kf899_sync(self, instance_id, state):
if self.scene_adapter is not None:
updates = {"power.enabled": state["power.enabled"], "coulometry.running": state["coulometry.running"],
"display.text": state["coulometry.status"], **{f"slot.{x}.installed": state[f"slot.{x}.installed"] for x in ("cell", "generator", "indicator")}}
self.scene_adapter(instance_id, _kf899_copy.deepcopy(updates))
def load_sample(self, *, instance_id, water_mass_kg, background_drift_kg_s, reagent_ready, request_id):
"""Host-only fixture initialization, never a robot or physical transfer.
A loaded sample may be started once. Loading another explicit fixture is
needed after any run, so restart cannot regenerate consumed water.
"""
with self._kf899_lock:
if not isinstance(instance_id, str) or instance_id not in self._kf899_instances:
raise ValueError("Unknown instance")
if not isinstance(request_id, str) or not request_id or not _kf899_number(water_mass_kg) or water_mass_kg < 0 or not _kf899_number(background_drift_kg_s) or background_drift_kg_s < 0 or type(reagent_ready) is not bool:
raise ValueError("Finite nonnegative SI truth, boolean reagent state and request_id required")
key = (instance_id, request_id)
fingerprint = (water_mass_kg, background_drift_kg_s, reagent_ready)
if key in self._kf899_host_requests:
if self._kf899_host_requests[key] != fingerprint:
raise ValueError("REQUEST_CONFLICT")
return {"status": "succeeded", "loaded": True, "synthetic": True}
instance = self._kf899_instances[instance_id]
if instance["state"]["coulometry.running"]:
raise ValueError("Cannot replace a running sample")
candidate = _kf899_copy.deepcopy(instance)
candidate.pop("template", None) # a new explicit fixture replaces any template-backed sample record
s = candidate["state"]
s.update({"sample.present": True, "reagent.ready": reagent_ready,
"truth.sample_water_kg": float(water_mass_kg), "truth.water_remaining_kg": float(water_mass_kg),
"truth.background_drift_kg_s": float(background_drift_kg_s), "measurement.drift_kg_s": float(background_drift_kg_s),
"measurement.water_mass_kg": None, "measurement.water_fraction": None,
"measurement.charge_c": 0.0, "measurement.elapsed_s": 0.0, "measurement.sample_time_s": None,
"endpoint.hold_elapsed_s": 0.0, "coulometry.status": "READY" if s["power.enabled"] else "OFF"})
candidate["curve"] = []
candidate["revision"] += 1
self._kf899_sync(instance_id, s)
self._kf899_instances[instance_id] = candidate
self._kf899_host_requests[key] = fingerprint
return {"status": "succeeded", "loaded": True, "synthetic": True}
def load_template_sample(self, *, instance_id, substance_id, sample_mass_kg, background_drift_kg_s, reagent_ready, request_id, temperature_k=None):
"""Host-only: weigh a public water-library material (hydrate, KF standard, water-saturated solvent) into the cell."""
return _kf899_template_module().load_template_sample(self, instance_id=instance_id, substance_id=substance_id,
sample_mass_kg=sample_mass_kg, background_drift_kg_s=background_drift_kg_s, reagent_ready=reagent_ready,
request_id=request_id, temperature_k=temperature_k)
def step(self, dt_s):
"""Integrate all devices against one clock; reads never call this method.
Exhaustion and endpoint hold are split analytically inside each step.
After water exhaustion, an ideal duty cycle supplies the drift current.
No electrode kinetics or manufacturer endpoint algorithm is asserted.
Failed callback leaves process/time unchanged; external scene side effects
remain unknown unless the callback actually satisfies its atomic contract.
"""
with self._kf899_lock:
if not _kf899_number(dt_s) or dt_s < 0 or not _kf899_number(self.time_s + dt_s):
raise ValueError("Finite nonnegative time increment required")
if dt_s == 0:
return {"time_s": self.time_s, "synthetic": True}
candidate = _kf899_copy.deepcopy(self._kf899_instances)
for iid, instance in candidate.items():
s = instance["state"]
if not s["coulometry.running"]:
continue
remaining_dt = float(dt_s)
advanced = 0.0
drift = s["truth.background_drift_kg_s"]
rate = s["settings.current_a"] * KF899_KG_PER_COULOMB
extract_remaining = max(0.0, s["settings.extraction_time_s"] - s["measurement.elapsed_s"])
extract = min(remaining_dt, extract_remaining)
s["truth.water_remaining_kg"] += drift * extract
remaining_dt -= extract
advanced += extract
s["coulometry.status"] = "EXTRACTING" if remaining_dt == 0 and extract_remaining > extract else "TITRATING"
if remaining_dt > 0:
water = s["truth.water_remaining_kg"]
net_rate = rate - drift
depletion_time = water / net_rate if net_rate > 0 else float("inf")
drive = min(remaining_dt, depletion_time)
s["measurement.charge_c"] += s["settings.current_a"] * drive
s["truth.water_remaining_kg"] = max(0.0, water - net_rate * drive)
remaining_dt -= drive
advanced += drive
if depletion_time <= drive:
s["truth.water_remaining_kg"] = 0.0
s["coulometry.status"] = "HOLDING"
hold_remaining = max(0.0, s["settings.endpoint_hold_s"] - s["endpoint.hold_elapsed_s"])
hold = min(remaining_dt, hold_remaining)
s["measurement.charge_c"] += drift * hold / KF899_KG_PER_COULOMB
s["endpoint.hold_elapsed_s"] += hold
advanced += hold
if s["endpoint.hold_elapsed_s"] >= s["settings.endpoint_hold_s"]:
s["coulometry.running"] = False
s["coulometry.status"] = "COMPLETED"
s["measurement.elapsed_s"] += advanced
generated = s["measurement.charge_c"] * KF899_KG_PER_COULOMB
compensation = s["settings.drift_compensation_kg_s"] * s["measurement.elapsed_s"]
s["measurement.water_mass_kg"] = max(0.0, generated - compensation)
mass = s["settings.sample_mass_kg"]
s["measurement.water_fraction"] = None if mass is None else s["measurement.water_mass_kg"] / mass
s["measurement.sample_time_s"] = self.time_s + advanced
if any(type(value) in (int, float) and not _kf899_number(value) for value in s.values()):
raise ValueError("Integration would exceed finite numerical range")
instance["revision"] += 1
record = _kf899_reading(s)
record["sample_time_s"] = s["measurement.sample_time_s"]
instance["curve"].append(record)
for iid, instance in candidate.items():
if instance != self._kf899_instances[iid]:
self._kf899_sync(iid, instance["state"])
self._kf899_instances = candidate
self.time_s += float(dt_s)
return {"time_s": self.time_s, "synthetic": True}
def _kf899_reading(state):
return {"status": state["coulometry.status"], "running": state["coulometry.running"],
"elapsed_s": state["measurement.elapsed_s"], "charge_c": state["measurement.charge_c"],
"water_mass_kg": state["measurement.water_mass_kg"], "water_fraction": state["measurement.water_fraction"],
"drift_kg_s": state["measurement.drift_kg_s"], "synthetic": True}
class Metrohm899Session:
"""API observation boundary for a host-registered principal; no hardware."""
def __init__(self, host, principal_id):
if principal_id not in host._kf899_principals:
raise ValueError("Host-assigned principal required")
self._kf899_host = host
self._kf899_principal = principal_id
def _kf899_allowed(self, instance_id):
return isinstance(instance_id, str) and instance_id in self._kf899_host._kf899_principals[self._kf899_principal]["instances"]
def _kf899_visible(self, state_id):
return not state_id.startswith("truth.") or self._kf899_host._kf899_principals[self._kf899_principal]["visibility"] != "agent"
def _kf899_response(self, instance_id, request_id=None, status="succeeded", result=None, observations=None, code=None, side_effects="none"):
host = self._kf899_host
instance = host._kf899_instances.get(instance_id) if isinstance(instance_id, str) and self._kf899_allowed(instance_id) else None
return {"protocol_version": "1.0.0", "instance_id": instance_id if isinstance(instance_id, str) else None,
"request_id": request_id if isinstance(request_id, str) else None, "operation_id": None,
"status": status, "state_revision": instance["revision"] if instance else None,
"clock": {"domain": "simulation", "time_s": host.time_s}, "result": result or {},
"observations": observations or {}, "error": None if code is None else {"code": code,
"message": {"UNKNOWN_INSTANCE": "Instance unavailable to this session", "UNKNOWN_CAPABILITY": "Unknown capability", "INVALID_ARGUMENT": "Arguments do not satisfy capability requirements", "PRECONDITION_FAILED": "Required powered, idle, assembled, reagent and method conditions are not met", "ACCESS_DENIED": "Access denied", "BUSY": "Measurement is already running", "REQUEST_CONFLICT": "Request identifier was already used with other arguments", "UNSUPPORTED": "No hardware or automatic-current adapter is implemented", "DEVICE_ERROR": "Scene callback failed; external scene effects are unknown"}.get(code, code),
"retryable": False, "side_effects": side_effects}}
def describe(self, *, asset_type_id=None, instance_id=None):
with self._kf899_host._kf899_lock:
if (asset_type_id is None) == (instance_id is None):
return self._kf899_response(instance_id, status="rejected", code="INVALID_ARGUMENT")
if instance_id is not None and not self._kf899_allowed(instance_id):
return self._kf899_response(instance_id, status="rejected", code="UNKNOWN_INSTANCE")
if asset_type_id is not None and asset_type_id != METROHM899_TYPE:
return self._kf899_response(instance_id, status="rejected", code="UNKNOWN_INSTANCE")
meta = export_metrohm899_contract_metadata()
meta["state_slots"] = {k: v for k, v in meta["state_slots"].items() if self._kf899_visible(k)}
meta["capabilities"].update(_kf899_template_module().capability_metadata()) # additive public-data extension
for cap in meta["capabilities"].values():
cap["state_effects"] = [e for e in cap["state_effects"] if self._kf899_visible(e["state_id"])]
meta.pop("host_capabilities")
meta["instance_id"] = instance_id
return meta
def read(self, *, instance_id, state_ids=None):
with self._kf899_host._kf899_lock:
if not self._kf899_allowed(instance_id):
return self._kf899_response(instance_id, status="rejected", code="UNKNOWN_INSTANCE")
instance = self._kf899_host._kf899_instances[instance_id]
if state_ids is None:
state_ids = [sid for sid in instance["state"] if self._kf899_visible(sid)]
if not isinstance(state_ids, list) or not all(isinstance(x, str) and x in instance["state"] for x in state_ids):
return self._kf899_response(instance_id, status="rejected", code="INVALID_ARGUMENT")
if any(not self._kf899_visible(sid) for sid in state_ids):
return self._kf899_response(instance_id, status="rejected", code="ACCESS_DENIED")
meta = export_metrohm899_contract_metadata()["state_slots"]
obs = {}
s = instance["state"]
for sid in state_ids:
value = _kf899_copy.deepcopy(s[sid])
measurement = sid.startswith("measurement.") and sid not in ("measurement.synthetic", "measurement.drift_kg_s")
sampled_at = s["measurement.sample_time_s"] if measurement else self._kf899_host.time_s
obs[sid] = {"value": value, "unit": meta[sid]["unit"], "quality": "unavailable" if value is None else "estimated" if meta[sid]["origin"] == "derived" else "valid",
"sample_time_s": sampled_at, "sample_window_s": [sampled_at - s["measurement.elapsed_s"], sampled_at] if measurement and sampled_at is not None and meta[sid]["sampling"]["mode"] == "integral" else None}
if value is None:
obs[sid]["reason"] = "No configured or acquired synthetic value"
return self._kf899_response(instance_id, observations=obs)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self._kf899_host
with host._kf899_lock:
if not self._kf899_allowed(instance_id):
return self._kf899_response(instance_id, request_id, "rejected", code="UNKNOWN_INSTANCE")
if not isinstance(request_id, str) or not request_id or not isinstance(capability_id, str) or not isinstance(arguments, dict):
return self._kf899_response(instance_id, request_id, "rejected", code="INVALID_ARGUMENT")
try:
fingerprint = _kf899_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False)
except (ValueError, TypeError, OverflowError):
return self._kf899_response(instance_id, request_id, "rejected", code="INVALID_ARGUMENT")
key = (self._kf899_principal, instance_id, request_id)
if key in host._kf899_requests:
previous = host._kf899_requests[key]
if previous[0] != fingerprint:
return self._kf899_response(instance_id, request_id, "rejected", code="REQUEST_CONFLICT")
return _kf899_copy.deepcopy(previous[1])
if capability_id in METROHM899_TEMPLATE_CAPABILITIES: # additive public-data extension; legacy capabilities unchanged
response = _kf899_template_module().invoke(self, host, instance_id, capability_id, arguments, request_id,
evaluator=host._kf899_principals[self._kf899_principal]["visibility"] != "agent")
host._kf899_requests[key] = (fingerprint, _kf899_copy.deepcopy(response))
host._kf899_logs.append({"instance_id": instance_id, "principal_id": self._kf899_principal, "request_id": request_id, "capability_id": capability_id, "status": response["status"]})
return _kf899_copy.deepcopy(response)
meta = export_metrohm899_contract_metadata()
definition = meta["capabilities"].get(capability_id)
if definition is None:
code = "UNSUPPORTED" if capability_id.startswith("hardware.") or capability_id == "coulometry.auto_current" else "ACCESS_DENIED" if capability_id.startswith("sim.") else "UNKNOWN_CAPABILITY"
return self._kf899_response(instance_id, request_id, "unsupported" if code == "UNSUPPORTED" else "rejected", code=code)
def reject(code):
response = self._kf899_response(instance_id, request_id, "rejected", code=code)
host._kf899_requests[key] = (fingerprint, _kf899_copy.deepcopy(response))
return response
if not _kf899_arguments_valid(capability_id, arguments):
return reject("INVALID_ARGUMENT")
instance = host._kf899_instances[instance_id]
candidate = _kf899_copy.deepcopy(instance)
s = candidate["state"]
result = None
if capability_id == "power.set":
s["power.enabled"] = arguments["enabled"]
if not arguments["enabled"]:
s["coulometry.running"] = False
s["coulometry.status"] = "OFF"
elif s["coulometry.status"] == "OFF":
s["coulometry.status"] = "READY" if s["sample.present"] else "IDLE"
result = {"enabled": arguments["enabled"]}
elif capability_id == "slot.set_installed":
if s["power.enabled"] or s["coulometry.running"]:
return reject("PRECONDITION_FAILED")
slot = arguments["slot"]
if slot != "cell" and arguments["installed"] and not s["slot.cell.installed"]:
return reject("PRECONDITION_FAILED")
if slot == "cell" and not arguments["installed"] and (s["slot.generator.installed"] or s["slot.indicator.installed"]):
return reject("PRECONDITION_FAILED")
s[f"slot.{slot}.installed"] = arguments["installed"]
result = dict(arguments)
elif capability_id == "coulometry.configure":
if s["coulometry.running"]:
return reject("BUSY")
for name, value in arguments.items():
s["settings." + name] = value
result = {name: s["settings." + name] for name in definition["output_schema"]["properties"]}
elif capability_id == "coulometry.start":
if s["coulometry.running"]:
return reject("BUSY")
if not s["power.enabled"] or not s["sample.present"] or not s["reagent.ready"] or not all(s[f"slot.{x}.installed"] for x in ("cell", "generator", "indicator")) or s["settings.drift_compensation_kg_s"] is None or s["settings.endpoint_hold_s"] is None or s["measurement.drift_kg_s"] > s["settings.start_drift_threshold_kg_s"] or instance["curve"] or s["measurement.sample_time_s"] is not None:
return reject("PRECONDITION_FAILED")
s.update({"coulometry.running": True, "coulometry.status": "EXTRACTING" if s["settings.extraction_time_s"] else "TITRATING", "measurement.elapsed_s": 0.0,
"measurement.charge_c": 0.0, "measurement.water_mass_kg": 0.0,
"measurement.water_fraction": None if s["settings.sample_mass_kg"] is None else 0.0,
"measurement.sample_time_s": host.time_s, "endpoint.hold_elapsed_s": 0.0})
result = _kf899_reading(s)
elif capability_id == "coulometry.stop":
if s["coulometry.running"]:
s["coulometry.running"] = False
s["coulometry.status"] = "STOPPED"
result = _kf899_reading(s)
elif capability_id == "coulometry.reading":
result = _kf899_reading(s)
elif capability_id == "coulometry.curve":
result = {"records": _kf899_copy.deepcopy(instance["curve"]), "synthetic": True}
if candidate != instance:
candidate["revision"] += 1
try:
host._kf899_sync(instance_id, s)
except Exception:
return self._kf899_response(instance_id, request_id, "failed", code="DEVICE_ERROR", side_effects="unknown")
host._kf899_instances[instance_id] = candidate
response = self._kf899_response(instance_id, request_id, result=result)
host._kf899_requests[key] = (fingerprint, _kf899_copy.deepcopy(response))
host._kf899_logs.append({"instance_id": instance_id, "principal_id": self._kf899_principal, "request_id": request_id, "capability_id": capability_id, "status": response["status"]})
return response
def write(self, *, instance_id, state_id, value, request_id):
with self._kf899_host._kf899_lock:
if not self._kf899_allowed(instance_id):
return self._kf899_response(instance_id, request_id, "rejected", code="UNKNOWN_INSTANCE")
slots = export_metrohm899_contract_metadata()["state_slots"]
if not isinstance(state_id, str) or state_id not in slots:
return self._kf899_response(instance_id, request_id, "rejected", code="INVALID_ARGUMENT")
route = slots[state_id]["write_via"]
if not self._kf899_visible(state_id) or route is None:
return self._kf899_response(instance_id, request_id, "rejected", code="ACCESS_DENIED")
args = {**route["fixed_arguments"], route["parameter"]: value}
return self.invoke(instance_id=instance_id, capability_id=route["capability_id"], arguments=args, request_id=request_id)
def logs(self):
with self._kf899_host._kf899_lock:
return _kf899_copy.deepcopy([row for row in self._kf899_host._kf899_logs if row["principal_id"] == self._kf899_principal and self._kf899_allowed(row["instance_id"])])
def _kf899_arguments_valid(capability, arguments):
if capability in ("coulometry.start", "coulometry.stop", "coulometry.reading", "coulometry.curve"):
return not arguments
if capability == "power.set":
return set(arguments) == {"enabled"} and type(arguments["enabled"]) is bool
if capability == "slot.set_installed":
return set(arguments) == {"slot", "installed"} and isinstance(arguments["slot"], str) and arguments["slot"] in ("cell", "generator", "indicator") and type(arguments["installed"]) is bool
if capability != "coulometry.configure":
return False
allowed = {"current_a", "drift_compensation_kg_s", "start_drift_threshold_kg_s", "extraction_time_s", "stirring_level", "sample_mass_kg", "endpoint_hold_s"}
if not arguments or not set(arguments) <= allowed:
return False
for name, value in arguments.items():
if name in ("drift_compensation_kg_s", "sample_mass_kg", "endpoint_hold_s") and value is None:
continue
if not _kf899_number(value):
return False
if name == "current_a" and value not in (0.1, 0.2, 0.4):
return False
if name == "start_drift_threshold_kg_s" and not KF899_START_DRIFT_MIN_KG_S <= value <= KF899_START_DRIFT_MAX_KG_S:
return False
if name == "extraction_time_s" and not 0 <= value <= 999999:
return False
if name == "stirring_level" and (type(value) is not int or not -15 <= value <= 15):
return False
if name in ("drift_compensation_kg_s", "endpoint_hold_s") and value < 0:
return False
if name == "sample_mass_kg" and value <= 0:
return False
return True
# END CHEM-102 METROHM 899 APPEND-ONLY RUNTIME
# CHEM-102 additive numerical/schema clarifications (preserve append-only file).
_kf899_original_step = Metrohm899Host.step
def _kf899_finite_step(self, dt_s):
"""Reject overflow in hidden intermediate integrals before any mutation.
This is a floating-point domain check, not a manufacturer operating limit.
An excessively large requested world step is rejected conservatively even
when the ideal endpoint would complete earlier inside that interval.
"""
with self._kf899_lock:
if _kf899_number(dt_s) and dt_s > 0:
for item in self._kf899_instances.values():
s = item["state"]
if s["coulometry.running"]:
candidates = (s["measurement.elapsed_s"] + dt_s,
s["settings.current_a"] * dt_s,
s["truth.water_remaining_kg"] + s["truth.background_drift_kg_s"] * dt_s,
s["settings.drift_compensation_kg_s"] * (s["measurement.elapsed_s"] + dt_s))
if not all(_kf899_number(v) for v in candidates):
raise ValueError("Requested integration exceeds finite numerical range")
return _kf899_original_step(self, dt_s)
Metrohm899Host.step = _kf899_finite_step
_kf899_original_metadata = export_metrohm899_contract_metadata
def export_metrohm899_contract_metadata():
result = _kf899_original_metadata()
for schema in (result["state_slots"]["settings.sample_mass_kg"]["value_schema"],
result["capabilities"]["coulometry.configure"]["input_schema"]["properties"]["sample_mass_kg"],
result["capabilities"]["coulometry.configure"]["output_schema"]["properties"]["sample_mass_kg"]):
number = schema["anyOf"][0]
number.pop("minimum", None)
number["exclusiveMinimum"] = 0
result["capabilities"]["coulometry.curve"]["meaning_zh"] = "返回每次运行中宿主步进后记录的合成滴定曲线;最后一点可使用步内解析完成时刻,不插值补造采样。"
result["boundaries"].append("Floating-point overflow is rejected before state/time mutation; excessively large requested steps may be conservatively rejected before endpoint clipping.")
return result
# BEGIN CHEM-101 METROHM OMNIS APPEND-ONLY RUNTIME
import copy as _omnis_copy
import hashlib as _omnis_hashlib
import json as _omnis_json
import math as _omnis_math
import threading as _omnis_threading
METROHM_OMNIS_TYPE = "instrument.metrohm_omnis"
METROHM_OMNIS_CYLINDERS_M3 = (5e-6, 1e-5, 2e-5, 5e-5)
METROHM_OMNIS_STEPS_PER_CYLINDER = 100000
METROHM_OMNIS_MAX_SPEED_RAD_S = 60 * _omnis_math.pi
METROHM_OMNIS_MAX_POINTS = 1024
METROHM_OMNIS_TEMPLATE_CAPABILITIES = ("template.list", "template.read", "titration.template_report")
def _omnis_template_module():
"""Lazy import of the public-data template extension (scripts/basic40_templates/metrohm_omnis.py)."""
try:
from .basic40_templates import metrohm_omnis as module
except ImportError:
from basic40_templates import metrohm_omnis as module
return module
def _omnis_num(unit, minimum=None, maximum=None, nullable=False, positive=False):
s = {"type": "number", "x-unit": unit}
if minimum is not None:
s["minimum"] = minimum
if maximum is not None:
s["maximum"] = maximum
if positive:
s["exclusiveMinimum"] = 0
return {"anyOf": [s, {"type": "null"}]} if nullable else s
def _omnis_obj(properties):
return {"type": "object", "properties": properties, "required": list(properties), "additionalProperties": False}
def _omnis_finite(v):
try:
return type(v) in (int, float) and _omnis_math.isfinite(v)
except (OverflowError, TypeError):
return False
def _omnis_matches(s, v):
if "anyOf" in s:
return any(_omnis_matches(branch, v) for branch in s["anyOf"])
typ = s.get("type")
if typ == "null":
return v is None
if typ == "object":
return isinstance(v, dict) and set(v) == set(s["properties"]) and all(_omnis_matches(s["properties"][k], x) for k, x in v.items())
if typ == "array":
return isinstance(v, list) and len(v) <= s.get("maxItems", len(v)) and all(_omnis_matches(s["items"], x) for x in v)
if typ in ("number", "integer"):
if not _omnis_finite(v) or (typ == "integer" and type(v) is not int):
return False
if ("minimum" in s and v < s["minimum"]) or ("maximum" in s and v > s["maximum"]) or ("exclusiveMinimum" in s and v <= s["exclusiveMinimum"]):
return False
elif typ == "boolean":
if type(v) is not bool:
return False
elif typ == "string":
if not isinstance(v, str) or len(v) < s.get("minLength", 0) or len(v) > s.get("maxLength", len(v)):
return False
else:
return False
return ("enum" not in s or v in s["enum"]) and ("const" not in s or v == s["const"])
def export_metrohm_omnis_contract_metadata():
"""Static metadata only; no sample fixture or instance truth is exported."""
boolean, synthetic = {"type": "boolean"}, {"type": "boolean", "const": True}
nullable_id = {"anyOf": [{"type": "string", "minLength": 1, "maxLength": 256}, {"type": "null"}]}
status = {"type": "string", "enum": ["idle", "running", "completed", "stopped", "out_of_range", "limit_reached"]}
mode = {"type": "string", "enum": ["endpoint", "dynamic_equivalent"]}
point = _omnis_obj({"time_s": _omnis_num("s", 0), "volume_m3": _omnis_num("m^3", 0),
"potential_v": _omnis_num("V", -2.4, 2.4), "ph": _omnis_num("1"), "synthetic": synthetic})
curve_schema = {"type": "array", "items": point, "maxItems": METROHM_OMNIS_MAX_POINTS}
slots = {}
def route(cap, parameter, fixed=None):
return {"capability_id": cap, "parameter": parameter, "fixed_arguments": fixed or {}}
def slot(sid, unit, origin, schema, text, write=None, visibility="agent", sampling="instant"):
slots[sid] = {"description_zh": text, "unit": unit, "origin": origin, "value_schema": schema,
"visibility": visibility, "access": "read_write" if write else "read_only", "write_via": write,
"read_binding": "MetrohmOmnisSession.read(instance_id=..., state_ids=[state_id])",
"sampling": {"mode": sampling, "time_domain": "simulation", "window": None}, "reference_conditions": None}
slot("power.enabled", "1", "setpoint", boolean, "逻辑供电;断电停止滴定,保留已加体积与曲线。", route("power.set", "enabled"))
for p in ("electrode", "titration_cell"):
slot("slot." + p + ".connection_id", "1", "scene", nullable_id, "可替换槽逻辑连接;非机械插拔或兼容性验证。", route("slot.set_connection", "connection_id", {"port_id": p}))
slot("dosing.cylinder_volume_m3", "m^3", "setpoint", {"anyOf": [{"type": "number", "enum": list(METROHM_OMNIS_CYLINDERS_M3), "x-unit": "m^3"}, {"type": "null"}]}, "单个缸槽容量,5/10/20/50mL换算SI。", route("dosing.configure_cylinder", "volume_m3"))
slot("dosing.quantum_m3", "m^3", "derived", _omnis_num("m^3", nullable=True), "选定容量/100000;分辨率不代表准确度。")
slot("dosing.rate_m3_s", "m^3/s", "setpoint", _omnis_num("m^3/s", nullable=True, positive=True), "用户显式加液速率;厂家上限未知。", route("dosing.set_rate", "rate_m3_s"))
slot("dosing.delivered_volume_m3", "m^3", "derived", _omnis_num("m^3", 0), "当前单缸实验已经加入的量化体积。")
slot("dosing.piston_fraction", "1", "derived", _omnis_num("1", 0, 1), "已加入体积/缸容量;仅供示意视觉映射,不等于真实活塞长度。")
slot("stirring.angular_speed_rad_s", "rad/s", "setpoint", _omnis_num("rad/s", 0, METROHM_OMNIS_MAX_SPEED_RAD_S), "1800 rpm = 60π rad/s;实际旋转还需逻辑电源。", route("stirring.set_speed", "angular_speed_rad_s"))
slot("stirring.angle_rad", "rad", "derived", _omnis_num("rad", 0, 2 * _omnis_math.pi), "共同宿主时间积分后的示意搅拌角。")
slot("titrant.concentration_mol_m3", "mol/m^3", "setpoint", _omnis_num("mol/m^3", nullable=True, positive=True), "用户给定强碱滴定剂浓度;不从隐藏样品真值反推。", route("titration.configure_titrant", "concentration_mol_m3"))
slot("method.mode", "1", "setpoint", {"anyOf": [mode, {"type": "null"}]}, "endpoint或dynamic_equivalent,后者为自定义有限差分算法。")
for sid, unit, text, nullable in (("method.dose_increment_m3", "m^3", "最大名义单次增量,动态模式可细分。", True), ("method.maximum_volume_m3", "m^3", "本次单缸最大累积加液体积。", True), ("method.endpoint_potential_v", "V", "endpoint模式明确给定的目标电位,动态模式为null。", True), ("stability.hold_s", "s", "显式稳定保持窗口;没有厂家默认值。", True), ("stability.tolerance_v", "V", "窗口内合成电位最大最小差的允许值。", True)):
slot(sid, unit, "setpoint", _omnis_num(unit, nullable=nullable), text)
slot("stability.stable", "1", "derived", boolean, "停止加液后窗口内合成读数符合显式稳定规则。")
slot("titration.status", "1", "derived", status, "完成只表示本工程假设算法结束;limit_reached可能未得到终点。")
slot("titration.running", "1", "derived", boolean, "只由host_step推进过程。")
slot("titration.phase", "1", "derived", {"type": "string", "enum": ["idle", "settling", "dosing", "finished"]}, "分段加液/稳定采样状态。")
slot("measurement.potential_v", "V", "derived", _omnis_num("V", -2.4, 2.4, True), "理想强酸强碱Nernst合成电位;越界为null。")
slot("measurement.ph", "1", "derived", _omnis_num("1", nullable=True), "由强酸强碱电中性与水离解计算的合成读数。")
slot("measurement.sample_time_s", "s", "derived", _omnis_num("s", 0, nullable=True), "最近宿主生成的合成测量时刻。")
slot("measurement.synthetic", "1", "derived", synthetic, "所有测量与曲线均为synthetic。")
slot("titration.curve", "1", "derived", curve_schema, "仅已稳定采点的观测序列;不含样品真值。", sampling="series")
slot("titration.endpoint_volume_m3", "m^3", "derived", _omnis_num("m^3", 0, nullable=True), "从观测曲线估算的终点体积,不读取宿主酸摩尔数求终点。")
slot("titration.content_mol_m3", "mol/m^3", "derived", _omnis_num("mol/m^3", 0, nullable=True), "按显式用户样品体积和化学计量比计算的含量。")
slot("display.text", "1", "derived", {"type": "string"}, "合成结果与运行状态的显示文本。")
for key, unit in (("volume_m3", "m^3"), ("acid_moles", "mol"), ("temperature_k", "K"), ("reference_ph", "1"), ("reference_potential_v", "V")):
slot("truth." + key, unit, "process_truth", _omnis_num(unit, nullable=True), "宿主专有的合成样品条件;agent不可读。", visibility="debug")
process_effects = [s for s in slots if s.startswith(("dosing.delivered", "dosing.piston", "stability.stable", "titration.", "measurement.", "display.")) and s != "titration.content_mol_m3"]
reset_effects = process_effects + ["titration.content_mol_m3"]
defs = {
"power.set": ({"enabled": boolean}, {"enabled": boolean}, {"enabled": True}, ["power.enabled", "titration.running", "titration.status", "titration.phase", "stability.stable", "display.text"], ["housing"], "设置逻辑供电;断电保留已经加入的体积和曲线。", "实例可用。"),
"slot.set_connection": ({"port_id": {"type": "string", "enum": ["electrode", "titration_cell"]}, "connection_id": nullable_id}, {"port_id": {"type": "string"}, "connection_id": nullable_id}, {"port_id": "electrode", "connection_id": "electrode_01"}, ["slot.electrode.connection_id", "slot.titration_cell.connection_id"], ["electrode_slot", "titration_cell_slot"], "登记可替换部件的逻辑槽连接。", "未在滴定;不执行机械插拔。"),
"dosing.configure_cylinder": ({"volume_m3": {"type": "number", "enum": list(METROHM_OMNIS_CYLINDERS_M3), "x-unit": "m^3"}}, {"volume_m3": _omnis_num("m^3")}, {"volume_m3": 2e-5}, ["dosing.cylinder_volume_m3", "dosing.quantum_m3", "dosing.piston_fraction"], ["cylinder_slot", "dosing_module"], "选择唯一缸槽容量,尚未实验时可改;每缸100000步。", "未运行、尚无已加液体积;已有方法的最大体积不可超容量。"),
"titration.configure_titrant": ({"concentration_mol_m3": _omnis_num("mol/m^3", positive=True)}, {"concentration_mol_m3": _omnis_num("mol/m^3", positive=True)}, {"concentration_mol_m3": 100}, ["titrant.concentration_mol_m3"], ["dosing_module"], "显式配置强碱滴定剂浓度。", "未运行且尚未加液。"),
"titration.configure_method": ({"mode": mode, "dose_increment_m3": _omnis_num("m^3", positive=True), "maximum_volume_m3": _omnis_num("m^3", positive=True), "endpoint_potential_v": _omnis_num("V", -2.4, 2.4, True)}, {"mode": mode, "dose_increment_m3": _omnis_num("m^3", positive=True), "maximum_volume_m3": _omnis_num("m^3", positive=True), "endpoint_potential_v": _omnis_num("V", -2.4, 2.4, True)}, {"mode": "endpoint", "dose_increment_m3": 1e-7, "maximum_volume_m3": 1.5e-5, "endpoint_potential_v": 0}, ["method.mode", "method.dose_increment_m3", "method.maximum_volume_m3", "method.endpoint_potential_v"], ["dosing_module"], "配置定电位终点或动态等当点合成方法。", "未运行且尚未加液;已选缸,增量和上限必须是缸步长整数倍;endpoint需要目标电位,动态模式目标为null。"),
"dosing.set_rate": ({"rate_m3_s": _omnis_num("m^3/s", positive=True)}, {"rate_m3_s": _omnis_num("m^3/s", positive=True)}, {"rate_m3_s": 1e-7}, ["dosing.rate_m3_s"], ["dosing_module"], "显式设定合成加液速率,不推断厂商流量范围。", "未运行;有限正数。"),
"titration.configure_stability": ({"hold_s": _omnis_num("s", positive=True), "tolerance_v": _omnis_num("V", 0)}, {"hold_s": _omnis_num("s", positive=True), "tolerance_v": _omnis_num("V", 0)}, {"hold_s": 0.5, "tolerance_v": 0.001}, ["stability.hold_s", "stability.tolerance_v"], ["electrode_slot"], "稳定窗口与电位容差由调用者显式给定。", "未运行;窗口正且容差非负;理想瞬时混合假设下静止加液窗口电位不变。"),
"stirring.set_speed": ({"angular_speed_rad_s": _omnis_num("rad/s", 0, METROHM_OMNIS_MAX_SPEED_RAD_S)}, {"angular_speed_rad_s": _omnis_num("rad/s", 0, METROHM_OMNIS_MAX_SPEED_RAD_S)}, {"angular_speed_rad_s": 10}, ["stirring.angular_speed_rad_s"], ["stir_bar", "stirrer_platform"], "设定搅拌角速度,上限1800rpm;不虚构混合时间常数。", "滴定运行中不得关闭搅拌;实际角度仅宿主推进。"),
"titration.start": ({}, {"status": status, "synthetic": synthetic}, {}, reset_effects, ["dosing_module", "electrode_slot", "titration_cell_slot", "stir_bar"], "启动分段加液/稳定采样;调用不加液、不产生读数、不推进时钟。", "电源、两个槽、缸、滴定剂、方法、速率、稳定规则、正搅拌速度和宿主样品齐备;开始单次实验前已加体积为0。"),
"titration.stop": ({}, {"status": status, "synthetic": synthetic}, {}, ["titration.status", "titration.running", "titration.phase", "stability.stable", "display.text"], ["dosing_module"], "停止并保留已加液体积及采点,已转移液体不回滚。", "实例可用;不支持停止后的续跑,宿主换样后才能新实验。"),
"titration.read_curve": ({}, {"samples": curve_schema, "endpoint_volume_m3": _omnis_num("m^3", 0, nullable=True), "status": status, "synthetic": synthetic}, {}, [], ["housing"], "读取合成曲线及估算终点,不推进时间、不访问样品真值。", "实例可用。"),
"titration.calculate_content": ({"sample_volume_m3": _omnis_num("m^3", positive=True), "stoichiometric_ratio": _omnis_num("1", positive=True)}, {"content_mol_m3": _omnis_num("mol/m^3", 0), "synthetic": synthetic}, {"sample_volume_m3": 2.5e-5, "stoichiometric_ratio": 1}, ["titration.content_mol_m3"], ["housing"], "含量=终点体积×用户滴定剂浓度×用户计量比/用户样品体积。", "算法已得到终点,且结果为有限数。"),
}
caps = {}
scene_keys = ["power.enabled", "slot.electrode.connection_id", "slot.titration_cell.connection_id", "dosing.cylinder_volume_m3", "dosing.delivered_volume_m3", "dosing.piston_fraction", "stirring.angle_rad", "stirring.angular_speed_rad_s", "display.text"]
for name, (inputs, outputs, example, effects, components, desc, pre) in defs.items():
scene_effects = [s for s in effects if s in scene_keys]
kind = "query" if name == "titration.read_curve" else "analysis" if name == "titration.calculate_content" else "configuration" if "configure" in name or name == "slot.set_connection" else "device_command"
caps[name] = {"availability": "implemented", "visibility": "agent", "kind": kind, "description_zh": desc,
"input_schema": _omnis_obj(inputs), "output_schema": _omnis_obj(outputs), "example_arguments": [example],
"state_effects": [{"state_id": s, "timing": "immediate", "description_zh": desc} for s in effects],
"observes": list(effects), "component_ids": components, "preconditions_zh": pre,
"binding": "basic40_runtime_measure.MetrohmOmnisSession.invoke(instance_id=..., capability_id='" + name + "', arguments=..., request_id=...)",
"completion_criterion_zh": "同步提交命令;实验完成须由host_step推进到completed并读取推断终点。",
"model_effects": {"mode": "host_required" if scene_effects else "none", "binding_ids": [], "description_zh": "可选scene_adapter接收只含允许场景键的快照;具体几何求值另验。" if scene_effects else "配置、曲线读取或纯分析不改变几何。"},
"implementation": {"process": "implemented", "host": "implemented", "scene": "declared" if scene_effects else "not_applicable", "robot": "absent", "hardware": "absent"},
"error_codes": ["UNKNOWN_INSTANCE", "UNKNOWN_CAPABILITY", "INVALID_ARGUMENT", "ACCESS_DENIED", "PRECONDITION_FAILED", "BUSY", "REQUEST_CONFLICT", "DEVICE_ERROR"], "retry": "same_request_id; in-memory only"}
def parameter(value, unit, evidence, text):
return {"value": value, "unit": unit, "meaning_zh": text, "evidence": evidence, "source_ids": ["workbook_parameters" if evidence == "catalog" else "runtime_code"], "uncertainty": None}
params = {
"cylinder_volumes_m3": parameter(list(METROHM_OMNIS_CYLINDERS_M3), "m^3", "catalog", "表列5/10/20/50mL选项。"),
"steps_per_cylinder": parameter(100000, "1", "catalog", "每缸加液分辨率,不等于精度。"),
"maximum_stirring_speed_rad_s": parameter(METROHM_OMNIS_MAX_SPEED_RAD_S, "rad/s", "catalog", "1800rpm换算60πrad/s。"),
"potential_range_v": parameter([-2.4, 2.4], "V", "catalog", "整机±2400mV测量范围。"),
"dynamic_target_delta_v": parameter(0.02, "V", "engineering_assumption", "自定义动态增量算法的目标电位变化;非厂家方法参数。"),
"dynamic_peak_fraction": parameter(0.8, "1", "engineering_assumption", "峰后两个较低斜率小于峰值80%才确认有限差分终点。"),
"max_curve_points": parameter(METROHM_OMNIS_MAX_POINTS, "1", "engineering_assumption", "运行层资源上限,不是厂商数据容量。"),
"water_ionic_product": parameter(1e-14, "1", "engineering_assumption", "浓度按mol/L归一后的Kw,固定25°C近似,温度仅进入Nernst斜率。"),
}
for key, unit in (("manufacturer_max_flow_rate", "m^3/s"), ("electrode_response_time", "s"), ("electrode_mass", "kg"), ("mixing_time_constant", "s"), ("sample_noise", "V"), ("cylinder_actual_stroke", "m"), ("cylinder_mass", "kg"), ("calibration_accuracy", "V"), ("fault_probability", "1")):
params[key] = parameter(None, unit, "unknown", "清单未给出,保持null;不以整机规格代替部件参数。")
limitations = ["All measurements, curves and content are synthetic; no real hardware, robotics, chemical calibration, noise or fault model is implemented.",
"Only ideal monoprotic strong-acid/strong-base 1:1 titration is simulated; redox/complexometry, weak acids, real kinetics, activity corrections, temperature-dependent Kw and manufacturer endpoint firmware are not implemented.",
"Host explicitly supplies sample conditions and absolute shared time. The ideal instantaneous-mixing model has constant potential while dosing is stopped; stability is checked over the explicit hold window.",
"One cylinder per run, no refill, flushing, sample transfer or physical insertion. Integer volume steps represent catalog resolution, not metrological accuracy.",
"Session filtering is an API boundary only; the trusted host, Python runtime and filesystem require separate deployment isolation. Debug truth never enters agent read/invoke/describe/logs or scene snapshots.",
"Request deduplication is in-memory only. Scene callback failure leaves process uncommitted but a partially changed external scene may need reconciliation.",
"Unknown manufacturer flow/stability/calibration parameters remain null; explicitly configured simulation inputs are not manufacturer specifications."]
return {"asset_types": {METROHM_OMNIS_TYPE: {"catalog_id": "CHEM-101", "model": "Metrohm | OMNIS Professional Titrator 2.1001.0320", "asset_version": "1.1.0", "state_slots": slots, "capabilities": caps, "parameters": params}},
"host_capabilities": {"sim.host_step": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "MetrohmOmnisRuntime.host_step(time_s)", "effects": reset_effects + ["stirring.angle_rad"]},
"sim.load_sample": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "MetrohmOmnisRuntime.host_load_sample(instance_id, sample)", "semantics_zh": "宿主设置新实验的合成真值、清空旧实验与活塞累计;不代表实际自动换样或缸补液。"}},
"scene_snapshot_keys": scene_keys, "limitations": limitations,
"engineering_equations": ["d=(n_acid-c_base*V_dosed)/(1000*(V_sample+V_dosed)); H=(d+sqrt(d*d+4*Kw))/2 with cancellation-safe branch; pH=-log10(H)",
"E=E_ref-ln(10)*R*T/F*(pH-pH_ref); R=8.31446261815324 J/(mol K), F=96485.33212331001 C/mol",
"quantum=V_cylinder/100000; delivered=integer_steps*quantum; theta=(theta+omega*dt) mod 2pi",
"endpoint: linear interpolation of observed E crossing; dynamic_equivalent: maximum observed |dE/dV| segment midpoint, confirmed by two later slopes < 0.8*peak",
"dynamic step=min(nominal_step, max(quantum, floor(0.02/last_abs_slope/quantum)*quantum)); content=V_endpoint*c_titrant*stoichiometric_ratio/V_user_sample"]}
class MetrohmOmnisRuntime:
"""Trusted host; hand a scoped Session, never this host, to an agent."""
def __init__(self, *, scene_adapter=None):
self.scene_adapter, self.time_s = scene_adapter, 0.0
self._instances, self._principals, self._requests, self._logs = {}, {}, {}, {}
self._lock, self._metadata = _omnis_threading.RLock(), export_metrohm_omnis_contract_metadata()
self.register_principal("__public_agent__", visibility="agent")
self._agent = self.session("__public_agent__")
def create_instance(self, instance_id, asset_type_id=METROHM_OMNIS_TYPE):
with self._lock:
if not isinstance(instance_id, str) or not instance_id or instance_id in self._instances or asset_type_id != METROHM_OMNIS_TYPE:
raise ValueError("Unique instance and declared asset type required")
inst = {"revision": 0, "power": False, "connections": {"electrode": None, "titration_cell": None},
"cylinder": None, "quantum": None, "rate": None, "speed": 0.0, "angle": 0.0, "concentration": None,
"method": None, "hold": None, "tolerance": None,
"truth": {key: None for key in ("volume_m3", "acid_moles", "temperature_k", "reference_ph", "reference_potential_v")}}
self._reset_run(inst)
if self.scene_adapter:
self.scene_adapter(instance_id, self._scene(inst))
self._instances[instance_id] = inst
@staticmethod
def _reset_run(inst):
inst.update({"steps": 0, "running": False, "status": "idle", "phase": "idle", "stable": False,
"curve": [], "ph": None, "potential": None, "sample_time": None, "endpoint": None, "content": None,
"event_time": None, "phase_start": None, "phase_start_steps": 0, "target_steps": 0,
"slopes": [], "settling_potential": None})
def register_principal(self, principal_id, *, visibility, instance_ids=None):
with self._lock:
if not isinstance(principal_id, str) or not principal_id or principal_id in self._principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Invalid trusted principal")
if instance_ids is not None and (not isinstance(instance_ids, (list, tuple, set, frozenset)) or any(not isinstance(x, str) for x in instance_ids)):
raise ValueError("Invalid instance scope")
scope = None if instance_ids is None else frozenset(instance_ids)
if scope is not None and not scope <= self._instances.keys():
raise ValueError("Unknown instance scope")
self._principals[principal_id], self._logs[principal_id] = (visibility, scope), []
def session(self, principal_id):
if principal_id not in self._principals:
raise ValueError("Trusted registration required")
return MetrohmOmnisSession(self, principal_id)
def describe(self, **kwargs):
return self._agent.describe(**kwargs)
def read(self, **kwargs):
return self._agent.read(**kwargs)
def invoke(self, **kwargs):
return self._agent.invoke(**kwargs)
def write(self, **kwargs):
return self._agent.write(**kwargs)
def describe_host(self):
return _omnis_copy.deepcopy(self._metadata["host_capabilities"])
@staticmethod
def _volume(inst):
return inst["steps"] * inst["quantum"] if inst["quantum"] else 0.0
@staticmethod
def _display(inst):
return "OFF" if not inst["power"] else "SYNTHETIC " + inst["status"] + (" %.3f mL" % (MetrohmOmnisRuntime._volume(inst) * 1e6))
@staticmethod
def _scene(inst):
return {"power.enabled": inst["power"], "slot.electrode.connection_id": inst["connections"]["electrode"],
"slot.titration_cell.connection_id": inst["connections"]["titration_cell"], "dosing.cylinder_volume_m3": inst["cylinder"],
"dosing.delivered_volume_m3": MetrohmOmnisRuntime._volume(inst), "dosing.piston_fraction": inst["steps"] / METROHM_OMNIS_STEPS_PER_CYLINDER,
"stirring.angle_rad": inst["angle"], "stirring.angular_speed_rad_s": inst["speed"], "display.text": MetrohmOmnisRuntime._display(inst)}
def scene_snapshot(self, instance_id):
with self._lock:
if instance_id not in self._instances:
raise ValueError("Unknown instance")
return _omnis_copy.deepcopy(self._scene(self._instances[instance_id]))
def apply_scene(self, instance_id):
with self._lock:
if self.scene_adapter is None:
raise RuntimeError("No scene adapter registered")
snapshot = self.scene_snapshot(instance_id)
self.scene_adapter(instance_id, snapshot)
return snapshot
@staticmethod
def _values(inst):
method = inst["method"] or {}
vals = {**MetrohmOmnisRuntime._scene(inst), "dosing.quantum_m3": inst["quantum"], "dosing.rate_m3_s": inst["rate"],
"titrant.concentration_mol_m3": inst["concentration"], "stability.hold_s": inst["hold"], "stability.tolerance_v": inst["tolerance"],
"stability.stable": inst["stable"], "titration.status": inst["status"], "titration.running": inst["running"], "titration.phase": inst["phase"],
"measurement.potential_v": inst["potential"], "measurement.ph": inst["ph"], "measurement.sample_time_s": inst["sample_time"],
"measurement.synthetic": True, "titration.curve": inst["curve"], "titration.endpoint_volume_m3": inst["endpoint"], "titration.content_mol_m3": inst["content"]}
vals.update({"method." + key: method.get(key) for key in ("mode", "dose_increment_m3", "maximum_volume_m3", "endpoint_potential_v")})
vals.update({"truth." + key: value for key, value in inst["truth"].items()})
return vals
def host_load_sample(self, instance_id, sample):
"""Explicit synthetic fixture/reset only; never expose through a Session."""
with self._lock:
inst = self._instances.get(instance_id)
expected = {"volume_m3", "acid_moles", "temperature_k", "reference_ph", "reference_potential_v"}
if inst is None or inst["running"]:
raise ValueError("Available stopped instance required")
if not isinstance(sample, dict) or set(sample) != expected or any(not _omnis_finite(v) for v in sample.values()):
raise ValueError("All explicit finite sample fields required")
if sample["volume_m3"] <= 0 or sample["acid_moles"] < 0 or sample["temperature_k"] <= 0:
raise ValueError("Positive sample volume/temperature and nonnegative acid required")
candidate = _omnis_copy.deepcopy(inst)
candidate.pop("template", None) # a new explicit fixture replaces any template-backed analyte
candidate["truth"] = {k: float(v) for k, v in sample.items()}
self._reset_run(candidate)
candidate["revision"] += 1
if self.scene_adapter and self._scene(candidate) != self._scene(inst):
self.scene_adapter(instance_id, self._scene(candidate))
self._instances[instance_id] = candidate
def host_load_template_sample(self, instance_id, analyte):
"""Trusted host only: analyte/titrant from the public acid-base library (weak/polyprotic charge balance)."""
return _omnis_template_module().load_template_sample(self, instance_id, analyte)
@staticmethod
def _potential(inst):
if inst.get("template") is not None: # template-backed analyte: library pKa(T) charge balance
return _omnis_template_module().potential(inst)
truth = inst["truth"]
volume = MetrohmOmnisRuntime._volume(inst)
d = (truth["acid_moles"] - inst["concentration"] * volume) / (1000 * (truth["volume_m3"] + volume))
root = _omnis_math.hypot(d, 2e-7)
h = (d + root) / 2 if d >= 0 else 2e-14 / (root - d)
ph = -_omnis_math.log10(h)
potential = truth["reference_potential_v"] - _omnis_math.log(10) * 8.31446261815324 * truth["temperature_k"] / 96485.33212331001 * (ph - truth["reference_ph"])
if not _omnis_finite(potential) or not _omnis_finite(ph):
raise ValueError("Synthetic response outside numeric domain")
return ph, potential
@staticmethod
def _measure(inst, time_s):
try:
ph, potential = MetrohmOmnisRuntime._potential(inst)
except (ValueError, OverflowError, ZeroDivisionError):
ph, potential = None, None
inst["sample_time"] = time_s
if potential is None or not -2.4 <= potential <= 2.4:
inst["ph"], inst["potential"], inst["status"], inst["running"], inst["phase"], inst["stable"] = None, None, "out_of_range", False, "finished", False
return False
inst["ph"], inst["potential"] = ph, potential
return True
@staticmethod
def _complete(inst, status):
inst["status"], inst["running"], inst["phase"], inst["event_time"] = status, False, "finished", None
@staticmethod
def _record(inst, time_s):
volume, potential = MetrohmOmnisRuntime._volume(inst), inst["potential"]
point = {"time_s": time_s, "volume_m3": volume, "potential_v": potential, "ph": inst["ph"], "synthetic": True}
previous = inst["curve"][-1] if inst["curve"] else None
inst["curve"].append(point)
method = inst["method"]
if method["mode"] == "endpoint":
target = method["endpoint_potential_v"]
if potential == target:
inst["endpoint"] = volume
elif previous and (previous["potential_v"] - target) * (potential - target) < 0:
inst["endpoint"] = previous["volume_m3"] + (volume - previous["volume_m3"]) * (target - previous["potential_v"]) / (potential - previous["potential_v"])
elif previous:
slope = abs((potential - previous["potential_v"]) / (volume - previous["volume_m3"]))
inst["slopes"].append({"slope": slope, "volume_m3": (volume + previous["volume_m3"]) / 2})
peak_index = max(range(len(inst["slopes"])), key=lambda n: inst["slopes"][n]["slope"])
peak = inst["slopes"][peak_index]
if peak_index >= 1 and len(inst["slopes"]) - peak_index >= 3 and all(s["slope"] < 0.8 * peak["slope"] for s in inst["slopes"][-2:]):
inst["endpoint"] = peak["volume_m3"]
if inst["endpoint"] is not None:
MetrohmOmnisRuntime._complete(inst, "completed")
elif inst["steps"] >= round(method["maximum_volume_m3"] / inst["quantum"]) or len(inst["curve"]) >= METROHM_OMNIS_MAX_POINTS:
MetrohmOmnisRuntime._complete(inst, "limit_reached")
else:
increment = round(method["dose_increment_m3"] / inst["quantum"])
if method["mode"] == "dynamic_equivalent" and inst["slopes"] and inst["slopes"][-1]["slope"] > 0:
increment = min(increment, max(1, int(0.02 / inst["slopes"][-1]["slope"] / inst["quantum"])))
target_steps = min(inst["steps"] + increment, round(method["maximum_volume_m3"] / inst["quantum"]))
inst["phase"], inst["phase_start"], inst["phase_start_steps"], inst["target_steps"] = "dosing", time_s, inst["steps"], target_steps
inst["event_time"] = time_s + (target_steps - inst["steps"]) * inst["quantum"] / inst["rate"]
inst["stable"] = False
def _advance(self, inst, start_time, end_time):
if inst["power"]:
inst["angle"] = (inst["angle"] + inst["speed"] * (end_time - start_time)) % (2 * _omnis_math.pi)
while inst["running"] and inst["event_time"] <= end_time:
event = inst["event_time"]
if inst["phase"] == "dosing":
inst["steps"] = inst["target_steps"]
if not self._measure(inst, event):
break
inst["phase"], inst["phase_start"] = "settling", event
inst["settling_potential"] = inst["potential"]
inst["event_time"] = event + inst["hold"]
else:
if not self._measure(inst, event):
break
first = inst["settling_potential"]
# The explicit ideal instantaneous-mixing process is constant during hold.
if first is None:
first = self._potential(inst)[1]
inst["stable"] = abs(inst["potential"] - first) <= inst["tolerance"]
if inst["stable"]:
self._record(inst, event)
else:
inst["settling_potential"], inst["event_time"] = inst["potential"], event + inst["hold"]
if inst["running"] and (not _omnis_finite(inst["event_time"]) or inst["event_time"] <= event):
raise ValueError("Host clock cannot resolve configured process interval")
if inst["running"] and inst["phase"] == "dosing":
elapsed = max(0.0, end_time - inst["phase_start"])
# Half-open step intervals prevent fractional catalog steps.
added = int(elapsed * inst["rate"] / inst["quantum"] + 1e-8)
inst["steps"] = min(inst["target_steps"], inst["phase_start_steps"] + added)
self._measure(inst, end_time)
def host_step(self, time_s):
"""Advance all instances atomically under one absolute simulation clock."""
with self._lock:
if not _omnis_finite(time_s) or time_s < self.time_s:
raise ValueError("Finite monotonic absolute host time required")
if time_s == self.time_s:
return {"time_s": self.time_s, "updated_instance_ids": []}
candidates = _omnis_copy.deepcopy(self._instances)
changed = []
for name, inst in candidates.items():
self._advance(inst, self.time_s, float(time_s))
if inst != self._instances[name]:
inst["revision"] += 1
changed.append(name)
if self.scene_adapter:
for name in changed:
if self._scene(candidates[name]) != self._scene(self._instances[name]):
self.scene_adapter(name, self._scene(candidates[name]))
self._instances, self.time_s = candidates, float(time_s)
return {"time_s": self.time_s, "updated_instance_ids": changed}
class MetrohmOmnisSession:
"""API filtering; not an in-process Python or filesystem security sandbox."""
def __init__(self, host, principal_id):
self.__host, self.__principal = host, principal_id
def _instance(self, instance_id):
_, scope = self.__host._principals[self.__principal]
return self.__host._instances.get(instance_id) if isinstance(instance_id, str) and (scope is None or instance_id in scope) else None
def _visible(self, slot):
visibility, _ = self.__host._principals[self.__principal]
return slot["visibility"] == "agent" or visibility in ("debug", "evaluator")
def _envelope(self, instance_id, request_id=None, *, status="succeeded", result=None, observations=None, error=None):
inst = self._instance(instance_id)
return {"protocol_version": "1.0.0", "instance_id": instance_id, "request_id": request_id, "operation_id": None,
"status": status, "state_revision": inst["revision"] if inst else None, "clock": {"domain": "simulation", "time_s": self.__host.time_s},
"result": _omnis_copy.deepcopy(result or {}), "observations": _omnis_copy.deepcopy(observations or {}), "error": error}
def _error(self, instance_id, code, request_id=None, status="rejected"):
text = {"UNKNOWN_INSTANCE": "Instance unavailable.", "UNKNOWN_CAPABILITY": "Capability unavailable.", "INVALID_ARGUMENT": "Invalid argument schema or numeric domain.", "ACCESS_DENIED": "Access policy denies this request.", "PRECONDITION_FAILED": "Required sample, configuration or operating state unavailable.", "BUSY": "Titration is running.", "REQUEST_CONFLICT": "Request identifier already used with different arguments.", "DEVICE_ERROR": "External scene synchronization failed; process was not committed."}
return self._envelope(instance_id, request_id, status=status, error={"code": code, "message": text[code], "retryable": False, "side_effects": "unknown" if code == "DEVICE_ERROR" else "none", "progress": None})
def describe(self, *, asset_type_id=None, instance_id=None):
with self.__host._lock:
if (asset_type_id is None) == (instance_id is None) or (asset_type_id is not None and asset_type_id != METROHM_OMNIS_TYPE):
return self._error(None, "INVALID_ARGUMENT")
if instance_id is not None and self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
_, scope = self.__host._principals[self.__principal]
if scope is not None and not scope:
return self._error(instance_id, "ACCESS_DENIED")
spec = _omnis_copy.deepcopy(self.__host._metadata["asset_types"][METROHM_OMNIS_TYPE])
spec["state_slots"] = {k: v for k, v in spec["state_slots"].items() if self._visible(v)}
spec["capabilities"].update(_omnis_template_module().capability_metadata()) # additive public-data extension
return {"protocol_version": "1.0.0", "asset_type_id": METROHM_OMNIS_TYPE, "instance_id": instance_id, "adapter": "basic40_runtime_measure.MetrohmOmnisSession", **spec,
"limitations": _omnis_copy.deepcopy(self.__host._metadata["limitations"])}
def read(self, *, instance_id, state_ids=None):
with self.__host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
slots = self.__host._metadata["asset_types"][METROHM_OMNIS_TYPE]["state_slots"]
if state_ids is None:
state_ids = [k for k, v in slots.items() if self._visible(v)]
if not isinstance(state_ids, list) or any(not isinstance(x, str) for x in state_ids) or len(state_ids) != len(set(state_ids)):
return self._error(instance_id, "INVALID_ARGUMENT")
if any(k not in slots or not self._visible(slots[k]) for k in state_ids):
return self._error(instance_id, "ACCESS_DENIED")
values = self.__host._values(inst)
observations = {k: {"value": _omnis_copy.deepcopy(values[k]), "unit": slots[k]["unit"], "quality": "unavailable" if values[k] is None else "estimated" if slots[k]["origin"] == "derived" else "valid",
"sample_time_s": inst["sample_time"] if k.startswith("measurement.") else self.__host.time_s, "sample_window_s": None,
"synthetic": slots[k]["origin"] == "derived", "reason": "No configured value or available synthetic result." if values[k] is None else None} for k in state_ids}
return self._envelope(instance_id, observations=observations)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
if not isinstance(capability_id, str) or not isinstance(arguments, dict) or not isinstance(request_id, str) or not 1 <= len(request_id) <= 256:
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
try:
digest = _omnis_hashlib.sha256(_omnis_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False).encode()).hexdigest()
except (TypeError, ValueError, OverflowError):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
key = self.__principal, instance_id, request_id
if key in host._requests:
old_digest, response = host._requests[key]
return _omnis_copy.deepcopy(response) if digest == old_digest else self._error(instance_id, "REQUEST_CONFLICT", request_id)
response = self._checked(instance_id, inst, capability_id, arguments, request_id)
host._requests[key] = digest, _omnis_copy.deepcopy(response)
host._logs[self.__principal].append({"instance_id": instance_id, "capability_id": capability_id, "request_id": request_id, "response": _omnis_copy.deepcopy(response)})
return response
def _checked(self, instance_id, inst, cap, args, request_id):
host = self.__host
if cap in METROHM_OMNIS_TEMPLATE_CAPABILITIES: # additive public-data extension; legacy capabilities unchanged
return _omnis_template_module().invoke(self, host, instance_id, inst, cap, args, request_id,
evaluator=self._visible({"visibility": "debug"}))
fail = lambda code, status="rejected": self._error(instance_id, code, request_id, status)
caps = host._metadata["asset_types"][METROHM_OMNIS_TYPE]["capabilities"]
if cap not in caps:
return fail("UNKNOWN_CAPABILITY")
if not _omnis_matches(caps[cap]["input_schema"], args):
return fail("INVALID_ARGUMENT")
idle_caps = ("slot.set_connection", "dosing.configure_cylinder", "titration.configure_titrant", "titration.configure_method", "dosing.set_rate", "titration.configure_stability", "titration.start")
if cap in idle_caps and inst["running"]:
return fail("BUSY")
if cap in ("dosing.configure_cylinder", "titration.configure_titrant", "titration.configure_method", "titration.start") and inst["steps"] > 0:
return fail("PRECONDITION_FAILED")
if cap == "dosing.configure_cylinder" and inst["method"] and inst["method"]["maximum_volume_m3"] > args["volume_m3"]:
return fail("PRECONDITION_FAILED")
if cap == "titration.configure_method":
q = inst["quantum"]
if q is None:
return fail("PRECONDITION_FAILED")
if (args["mode"] == "endpoint") != (args["endpoint_potential_v"] is not None):
return fail("INVALID_ARGUMENT")
if args["dose_increment_m3"] > args["maximum_volume_m3"] or args["maximum_volume_m3"] > inst["cylinder"]:
return fail("INVALID_ARGUMENT")
for key in ("dose_increment_m3", "maximum_volume_m3"):
steps = args[key] / q
if not _omnis_finite(steps) or steps < 1 or abs(steps - round(steps)) > 1e-7:
return fail("INVALID_ARGUMENT")
if cap == "stirring.set_speed" and inst["running"] and args["angular_speed_rad_s"] == 0:
return fail("PRECONDITION_FAILED")
if cap == "titration.start":
if not inst["power"] or not all(inst["connections"].values()) or any(inst[k] is None for k in ("cylinder", "rate", "concentration", "method", "hold", "tolerance")) or inst["speed"] <= 0 or inst["truth"]["volume_m3"] is None:
return fail("PRECONDITION_FAILED")
try:
period = inst["quantum"] / inst["rate"]
response = host._potential(inst)
if not _omnis_finite(period) or period <= 0 or host.time_s + period <= host.time_s or host.time_s + inst["hold"] <= host.time_s or not all(_omnis_finite(x) for x in response):
return fail("INVALID_ARGUMENT")
except (ValueError, OverflowError, ZeroDivisionError):
return fail("INVALID_ARGUMENT")
if cap == "titration.calculate_content":
if inst["endpoint"] is None or inst["running"]:
return fail("PRECONDITION_FAILED")
try:
content = inst["endpoint"] * inst["concentration"] * args["stoichiometric_ratio"] / args["sample_volume_m3"]
except (ValueError, OverflowError, ZeroDivisionError):
return fail("INVALID_ARGUMENT")
if not _omnis_finite(content):
return fail("INVALID_ARGUMENT")
if cap == "titration.read_curve":
return self._envelope(instance_id, request_id, result={"samples": inst["curve"], "endpoint_volume_m3": inst["endpoint"], "status": inst["status"], "synthetic": True})
candidate, result = _omnis_copy.deepcopy(inst), dict(args)
if cap == "power.set":
candidate["power"] = args["enabled"]
if not args["enabled"] and candidate["running"]:
host._complete(candidate, "stopped")
candidate["stable"] = False
elif cap == "slot.set_connection":
candidate["connections"][args["port_id"]] = args["connection_id"]
elif cap == "dosing.configure_cylinder":
candidate["cylinder"], candidate["quantum"] = args["volume_m3"], args["volume_m3"] / METROHM_OMNIS_STEPS_PER_CYLINDER
elif cap == "titration.configure_titrant":
candidate["concentration"] = args["concentration_mol_m3"]
elif cap == "titration.configure_method":
candidate["method"] = dict(args)
elif cap == "dosing.set_rate":
candidate["rate"] = args["rate_m3_s"]
elif cap == "titration.configure_stability":
candidate["hold"], candidate["tolerance"] = args["hold_s"], args["tolerance_v"]
elif cap == "stirring.set_speed":
candidate["speed"] = args["angular_speed_rad_s"]
elif cap == "titration.start":
host._reset_run(candidate)
candidate["running"], candidate["status"], candidate["phase"] = True, "running", "settling"
candidate["phase_start"], candidate["event_time"] = host.time_s, host.time_s + candidate["hold"]
result = {"status": candidate["status"], "synthetic": True}
elif cap == "titration.stop":
if candidate["running"]:
host._complete(candidate, "stopped")
candidate["stable"] = False
result = {"status": candidate["status"], "synthetic": True}
elif cap == "titration.calculate_content":
candidate["content"] = content
result = {"content_mol_m3": content, "synthetic": True}
if host.scene_adapter and host._scene(candidate) != host._scene(inst):
try:
host.scene_adapter(instance_id, host._scene(candidate))
except Exception:
return fail("DEVICE_ERROR", "failed")
if candidate != inst:
candidate["revision"] += 1
host._instances[instance_id] = candidate
return self._envelope(instance_id, request_id, result=result)
def write(self, *, instance_id, state_id, value, request_id):
with self.__host._lock:
if self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
slots = self.__host._metadata["asset_types"][METROHM_OMNIS_TYPE]["state_slots"]
if not isinstance(state_id, str) or state_id not in slots or not self._visible(slots[state_id]) or slots[state_id]["write_via"] is None:
return self._error(instance_id, "ACCESS_DENIED", request_id)
route = slots[state_id]["write_via"]
return self.invoke(instance_id=instance_id, capability_id=route["capability_id"], arguments={**route["fixed_arguments"], route["parameter"]: value}, request_id=request_id)
def logs(self):
with self.__host._lock:
return _omnis_copy.deepcopy(self.__host._logs[self.__principal])
def write_metrohm_omnis_runtime_reports(output_directory):
import datetime
import importlib.util
import io
import pathlib
import platform
import unittest
root = pathlib.Path(__file__).resolve().parents[1]
spec = importlib.util.spec_from_file_location("test_basic40_measure_omnis", root / "tests/test_basic40_measure.py")
module = importlib.util.module_from_spec(spec)
spec.loader.exec_module(module)
stream = io.StringIO()
result = unittest.TextTestRunner(stream=stream, verbosity=2).run(unittest.defaultTestLoader.loadTestsFromTestCase(module.MetrohmOmnisRuntimeTests))
metadata = export_metrohm_omnis_contract_metadata()
report = {"catalog_id": "CHEM-101", "checked_at": datetime.datetime.now(datetime.timezone.utc).isoformat(),
"environment": {"python": platform.python_version(), "platform": platform.platform(), "runtime": "standard-library Python; synthetic fixtures; no Blender"},
"method": "unittest: all 12 APIs and schemas/effects; synthetic endpoint and dynamic titration, dose quantization, stable hold, content, partial stop, host time partition equivalence, range rejection, atomic failure, scoped visibility, request deduplication, instance isolation and scene callbacks",
"tests_run": result.testsRun, "failures": len(result.failures), "errors": len(result.errors), "result": "passed" if result.wasSuccessful() else "failed",
"passed_capabilities": sorted(metadata["asset_types"][METROHM_OMNIS_TYPE]["capabilities"]) if result.wasSuccessful() else [],
"output": stream.getvalue(), "not_run": ["real_hardware", "robot_execution", "contact_solver", "Blender_evaluated_pose", "process_filesystem_security_isolation", "manufacturer_calibration_accuracy", "redox_complexometric_weak_acid_response", "real_response_noise_fault_probability"],
"scene_scope": "Only snapshot and recording/failing callbacks tested; parent provides evaluated Blender scene verification separately.", "synthetic": True}
directory = pathlib.Path(output_directory)
directory.mkdir(parents=True, exist_ok=True)
for name, value in (("runtime_validation.json", report), ("runtime_metadata.json", metadata)):
(directory / name).write_text(_omnis_json.dumps(value, ensure_ascii=False, indent=2) + "\n", encoding="utf-8")
return report
# END CHEM-101 METROHM OMNIS APPEND-ONLY RUNTIME
# CHEM-101 append-only numeric-domain guards and contract mechanism declarations.
_omnis_export_base = export_metrohm_omnis_contract_metadata
def export_metrohm_omnis_contract_metadata():
metadata = _omnis_export_base()
params = metadata["asset_types"][METROHM_OMNIS_TYPE]["parameters"]
def props(*names):
result = {name: _omnis_copy.deepcopy(params[name]) for name in names}
for prop in result.values():
prop["evidence"] = {"catalog": "documented", "engineering_assumption": "assumption"}.get(prop["evidence"], prop["evidence"])
return result
metadata["mechanisms"] = {
"ideal_acid_base_potentiometry": {
"component_ids": ["electrode_slot", "titration_cell_slot", "dosing_module"],
"state_ids": ["truth.acid_moles", "truth.volume_m3", "truth.temperature_k", "truth.reference_ph", "truth.reference_potential_v", "titrant.concentration_mol_m3", "dosing.delivered_volume_m3", "measurement.ph", "measurement.potential_v"],
"meaning_zh": "engineering_assumption:单元强酸强碱电中性/水离解理想响应及Nernst电位;所有输出synthetic。",
"implementation": "numerical", "equations": metadata["engineering_equations"][:2],
"parameters": props("water_ionic_product", "potential_range_v", "electrode_response_time", "sample_noise", "calibration_accuracy"),
"source_ids": ["runtime_code", "workbook_parameters"],
"limitations": ["固定Kw的25°C近似,仅Nernst斜率含显式温度;无活度、弱酸、氧化还原、络合和真实动力学。", "严格超过整机±2.4V时输出null并停止,不做限幅伪装读数;不声称厂家准确度。"]},
"quantized_dosing_and_stirring": {
"component_ids": ["dosing_module", "cylinder_slot", "piston_proxy", "stir_bar"],
"state_ids": ["dosing.cylinder_volume_m3", "dosing.quantum_m3", "dosing.rate_m3_s", "dosing.delivered_volume_m3", "dosing.piston_fraction", "stirring.angular_speed_rad_s", "stirring.angle_rad"],
"meaning_zh": "engineering_assumption:表列每缸100000步作为整数体积格点;宿主时钟推进恒定速率加液并积分搅拌角。",
"implementation": "numerical", "equations": [metadata["engineering_equations"][2]],
"parameters": props("cylinder_volumes_m3", "steps_per_cylinder", "maximum_stirring_speed_rad_s", "manufacturer_max_flow_rate", "mixing_time_constant", "cylinder_actual_stroke"),
"source_ids": ["runtime_code", "workbook_parameters"],
"limitations": ["单缸实验无补液和实际物质转移;host_load_sample仅显式重置合成实验。", "活塞占比为示意模型映射,不代表实际缸行程;搅拌未模拟磁耦合/失步/液体动力学。"]},
"stable_curve_and_endpoint": {
"component_ids": ["electrode_slot", "titration_cell_slot", "dosing_module"],
"state_ids": ["method.mode", "method.dose_increment_m3", "method.maximum_volume_m3", "method.endpoint_potential_v", "stability.hold_s", "stability.tolerance_v", "stability.stable", "titration.curve", "titration.endpoint_volume_m3", "titration.content_mol_m3"],
"meaning_zh": "engineering_assumption:停液后的显式稳定窗口采点,固定目标电位线性插值或动态有限差分峰值估算终点。",
"implementation": "numerical", "equations": ["stable=(max(E over hold window)-min(E over hold window)<=user tolerance); ideal instantaneous mixing keeps E constant while dosing is stopped", *metadata["engineering_equations"][3:]],
"parameters": props("dynamic_target_delta_v", "dynamic_peak_fraction", "max_curve_points", "fault_probability"),
"source_ids": ["runtime_code", "workbook_parameters"],
"limitations": ["动态方法为可复现教学算法,未复现Metrohm固件;终点可能因剂量上限/点数上限未找到,此时为null。", "结果仅基于代理可观察曲线;计算含量使用调用者明确给出的样品体积、滴定剂浓度和计量比。"]}}
metadata["limitations"].append("Finite numeric representability is checked at host boundaries; changing cylinder preserves the integer-step consistency of an already configured method.")
return metadata
class MetrohmOmnisRuntime(MetrohmOmnisRuntime):
"""Append-only hardening of the CHEM-101 host; public signature unchanged."""
def host_step(self, time_s):
with self._lock:
if not _omnis_finite(time_s) or time_s < self.time_s:
raise ValueError("Finite monotonic absolute host time required")
delta = time_s - self.time_s
if not _omnis_finite(delta) or any(inst["power"] and not _omnis_finite(inst["speed"] * delta) for inst in self._instances.values()):
raise ValueError("Step rotation exceeds finite numeric domain")
return super().host_step(time_s)
class MetrohmOmnisSession(MetrohmOmnisSession):
"""Append-only cylinder/method consistency guard; identity policy unchanged."""
def _checked(self, instance_id, inst, cap, args, request_id):
if cap == "dosing.configure_cylinder" and set(args) == {"volume_m3"} and _omnis_finite(args["volume_m3"]) and args["volume_m3"] in METROHM_OMNIS_CYLINDERS_M3 and inst["method"] is not None:
quantum = args["volume_m3"] / METROHM_OMNIS_STEPS_PER_CYLINDER
for key in ("dose_increment_m3", "maximum_volume_m3"):
steps = inst["method"][key] / quantum
if steps < 1 or abs(steps - round(steps)) > 1e-7:
return self._error(instance_id, "PRECONDITION_FAILED", request_id)
return super()._checked(instance_id, inst, cap, args, request_id)
# BEGIN CHEM-068 MAGRITEK SPINSOLVE 80 APPEND-ONLY RUNTIME
import copy as _sp80_copy
import cmath as _sp80_cmath
import hashlib as _sp80_hashlib
import json as _sp80_json
import math as _sp80_math
import threading as _sp80_threading
from datetime import datetime as _sp80_datetime, timezone as _sp80_timezone
from pathlib import Path as _sp80_Path
MAGRIΤEK_SPINSOLVE80_RESERVED = None # Names below use ASCII identifiers.
SPINSOLVE80_TYPE = "instrument.magritek_spinsolve80"
SPINSOLVE80_SCENE_KEYS = ("power.enabled", "slot.sample_tube.connection_id", "sample.insertion_fraction", "acquisition.running", "acquisition.progress", "display.text")
def _sp80_number(value):
try:
return type(value) in (int, float) and _sp80_math.isfinite(value)
except (TypeError, OverflowError):
return False
def _sp80_num(unit, lo=None, hi=None, *, integer=False, positive=False, nullable=False):
result = {"type": "integer" if integer else "number", "x-unit": unit}
if lo is not None:
result["minimum"] = lo
if hi is not None:
result["maximum"] = hi
if positive:
result["exclusiveMinimum"] = 0
return {"anyOf": [result, {"type": "null"}]} if nullable else result
def _sp80_obj(properties):
return {"type": "object", "properties": properties, "required": list(properties), "additionalProperties": False}
def _sp80_nullable(schema):
return {"anyOf": [schema, {"type": "null"}]}
def _sp80_matches(schema, value):
if "anyOf" in schema:
return any(_sp80_matches(s, value) for s in schema["anyOf"])
typ = schema.get("type")
if typ in ("number", "integer"):
if not _sp80_number(value) or (typ == "integer" and type(value) is not int):
return False
elif typ == "object":
if not isinstance(value, dict) or set(value) != set(schema["properties"]):
return False
return all(_sp80_matches(s, value[k]) for k, s in schema["properties"].items())
elif typ == "array":
return isinstance(value, list) and schema.get("minItems", 0) <= len(value) <= schema.get("maxItems", 100000) and all(_sp80_matches(schema["items"], v) for v in value)
elif typ == "boolean" and type(value) is not bool:
return False
elif typ == "string" and (not isinstance(value, str) or not schema.get("minLength", 0) <= len(value) <= schema.get("maxLength", 100000)):
return False
elif typ == "null" and value is not None:
return False
if "const" in schema and (type(value) is not type(schema["const"]) or value != schema["const"]):
return False
if "enum" in schema and value not in schema["enum"]:
return False
return all(value >= schema[k] if k == "minimum" else value <= schema[k] if k == "maximum" else value > schema[k] for k in ("minimum", "maximum", "exclusiveMinimum") if k in schema)
def export_magritek_spinsolve80_contract_metadata():
"""Contract-ready type metadata, with no runtime sample values or fixtures."""
boolean, synthetic = {"type": "boolean"}, {"type": "boolean", "const": True}
identifier = {"type": "string", "minLength": 1, "maxLength": 128}
nucleus = {"type": "string", "enum": ["1H", "13C"]}
status = {"type": "string", "enum": ["idle", "running", "completed", "stopped"]}
method = {"nucleus": nucleus, "pulse_sequence": {"type": "string", "enum": ["single_pulse"]},
"scans": _sp80_num("1", 1, 4096, integer=True), "relaxation_delay_s": _sp80_num("s", 0, 86400),
"acquisition_time_s": _sp80_num("s", 0.001, 60), "points": _sp80_num("1", 32, 512, integer=True),
"decoupling": boolean, "gradient_enabled": boolean}
fid = {"type": "array", "maxItems": 512, "items": _sp80_obj({"time_s": _sp80_num("s", 0), "real": _sp80_num("1"), "imaginary": _sp80_num("1"), "synthetic": synthetic})}
spectrum = {"type": "array", "maxItems": 512, "items": _sp80_obj({"frequency_offset_hz": _sp80_num("Hz"), "real": _sp80_num("1"), "imaginary": _sp80_num("1"), "amplitude": _sp80_num("1", 0), "synthetic": synthetic})}
resonance = _sp80_obj({"frequency_offset_hz": _sp80_num("Hz", -1e6, 1e6), "amplitude": _sp80_num("1", 0, 1e6), "t2_s": _sp80_num("s", 1e-6, 1e6)})
peaks = {"type": "array", "maxItems": 32, "items": resonance}
fixture = _sp80_obj({"1H": peaks, "13C": peaks})
registered = {"type": "array", "maxItems": 64, "items": _sp80_obj({"sample_id": identifier, "signals": fixture})}
slots = {}
def slot(sid, schema, unit, origin, text, components, *, visibility="agent", write=None, sampling="instant"):
slots[sid] = {"component_ids": components, "value_schema": schema, "unit": unit, "reference_conditions": None,
"meaning_zh": text, "origin": origin, "access": "read_write" if write else "read_only", "visibility": visibility,
"read_binding": {"backend": "process", "artifact_id": "runtime_code", "accessor": "MagritekSpinsolve80Session.read(instance_id=..., state_ids=['" + sid + "'])"},
"write_via": write, "sampling": {"mode": sampling, "time_domain": "simulation", "window_description": "已完成扫描的无噪声平均信号。" if sampling == "series" else None}, "source_ids": ["runtime_code"]}
slot("power.enabled", boolean, "1", "setpoint", "逻辑电源;关闭时停止采集并保留已完成扫描。", ["housing"], write={"capability_id": "power.set", "argument": "enabled", "fixed_arguments": {}})
slot("slot.sample_tube.connection_id", _sp80_nullable(identifier), "1", "scene", "唯一管槽的宿主注册样品标识;不暴露样品信号真值。", ["sample_port", "sample_tube"])
slot("sample.insertion_fraction", _sp80_num("1", 0, 1), "1", "scene", "放样为1、移除为0;几何插入深度另以假设声明,不是厂家行程。", ["sample_tube"])
for key, schema in method.items():
slot("method." + key, _sp80_nullable(schema), schema.get("x-unit", "1"), "setpoint", "用户显式合成采集设置;资源范围为engineering_assumption,不是厂家规格。", ["magnet_module"])
slot("method.carrier_frequency_hz", _sp80_num("Hz", nullable=True), "Hz", "derived", "1H载频为清单80 MHz;13C载频未知为null,合成横轴始终用Hz偏移。", ["magnet_module"])
for sid, schema, unit, text in (("acquisition.status", status, "1", "采集状态;完成不代表真实仪器采集。"), ("acquisition.running", boolean, "1", "宿主时间推进的合成采集是否运行。"), ("acquisition.progress", _sp80_num("1", 0, 1), "1", "本次采集计划的时间完成比例。"), ("acquisition.completed_scans", _sp80_num("1", 0, 4096, integer=True), "1", "已完整结束的扫描数量;未完成扫描不输出伪完整数据。"), ("acquisition.elapsed_s", _sp80_num("s", 0), "s", "宿主推进后的本次采集耗时。"), ("measurement.sample_time_s", _sp80_num("s", 0, nullable=True), "s", "最近完整扫描的结束时刻。"), ("measurement.synthetic", synthetic, "1", "FID、1D频谱与积分全部为synthetic。")):
slot(sid, schema, unit, "derived", text, ["magnet_module"])
slot("measurement.fid", fid, "1", "derived", "阻尼复正弦叠加的合成FID;信号幅值无量纲。", ["magnet_module"], sampling="series")
slot("measurement.spectrum", spectrum, "1", "derived", "对合成FID执行归一化DFT的1D频谱;频率偏移单位Hz,幅值无量纲。", ["magnet_module"], sampling="series")
slot("measurement.integral_hz", _sp80_num("Hz", 0, nullable=True), "Hz", "derived", "按指定频带对幅度做分段线性积分;不是核数、浓度或定量核磁结果。", ["control_panel"])
slot("display.text", {"type": "string"}, "1", "derived", "状态标签,始终带SYNTHETIC;未新增厂商自带屏幕主张。", ["control_panel"])
slot("truth.registered_samples", registered, "1", "process_truth", "宿主专有合成样品表;代理describe/read/invoke/logs/scene均不含这些真值。", ["sample_port"], visibility="debug", sampling="static")
reset = ["acquisition.status", "acquisition.running", "acquisition.progress", "acquisition.completed_scans", "acquisition.elapsed_s", "measurement.sample_time_s", "measurement.fid", "measurement.spectrum", "measurement.integral_hz", "display.text"]
example = {"nucleus": "1H", "pulse_sequence": "single_pulse", "scans": 2, "relaxation_delay_s": 1, "acquisition_time_s": 0.5, "points": 64, "decoupling": False, "gradient_enabled": False}
defs = {
"power.set": ("device_command", {"enabled": boolean}, {"enabled": boolean}, {"enabled": True}, ["housing", "control_panel"], ["power.enabled", "acquisition.running", "acquisition.status", "display.text"], "设置逻辑电源,关闭保留已完成扫描。", "实例存在。"),
"sample.insert": ("configuration", {"sample_id": identifier}, {"sample_id": identifier, "insertion_fraction": _sp80_num("1", 0, 1)}, {"sample_id": "sample_01"}, ["sample_port", "sample_tube"], ["slot.sample_tube.connection_id", "sample.insertion_fraction"] + reset, "将已由宿主注册的样品放入唯一逻辑管槽,示意场景同步由宿主适配器执行。", "槽为空、未采集、样品在本实例宿主注册表内;不执行真实机械插入。"),
"sample.remove": ("configuration", {}, {"sample_id": _sp80_nullable(identifier), "insertion_fraction": _sp80_num("1", 0, 1)}, {}, ["sample_port", "sample_tube"], ["slot.sample_tube.connection_id", "sample.insertion_fraction"] + reset, "清空逻辑槽及当前运行结果;不从世界删除样品。", "未采集。"),
"acquisition.configure": ("configuration", method, method, example, ["magnet_module", "control_panel"], ["method." + k for k in method] + ["method.carrier_frequency_hz"] + reset, "显式配置1H/13C单脉冲合成采集;解耦或梯度启用明确拒绝。", "未采集;所有数值有限且满足计算资源范围;decoupling和gradient_enabled须为false。"),
"acquisition.start": ("device_command", {}, {"status": status, "synthetic": synthetic}, {}, ["magnet_module", "control_panel"], reset, "启动采集计划;调用不推进时间,也不立即生成FID。", "逻辑供电、已插样、完整方法齐备、未运行;选定核的宿主信号存在且位于Nyquist范围内。"),
"acquisition.stop": ("device_command", {}, {"status": status, "completed_scans": _sp80_num("1", 0, 4096, integer=True), "synthetic": synthetic}, {}, ["magnet_module", "control_panel"], ["acquisition.running", "acquisition.status", "display.text"], "停止采集,保留已完整扫描及耗时;未完成扫描丢弃,不伪称完成。", "实例存在;未运行时为无操作。"),
"nmr.read_fid": ("query", {}, {"samples": fid, "completed_scans": _sp80_num("1", 0, 4096, integer=True), "status": status, "synthetic": synthetic}, {}, ["magnet_module"], [], "读取已有合成FID,不推进时间、不读取隐藏样品参数。", "实例存在;尚无完整扫描时数组为空。"),
"nmr.read_spectrum": ("query", {}, {"samples": spectrum, "nucleus": _sp80_nullable(nucleus), "carrier_frequency_hz": _sp80_num("Hz", nullable=True), "status": status, "synthetic": synthetic}, {}, ["magnet_module"], [], "读取已有1D合成DFT谱;不提供2D谱或结构约束。", "实例存在;尚无完整扫描时数组为空。"),
"nmr.integrate": ("analysis", {"frequency_min_hz": _sp80_num("Hz"), "frequency_max_hz": _sp80_num("Hz")}, {"integral_hz": _sp80_num("Hz", 0), "synthetic": synthetic}, {"frequency_min_hz": -10, "frequency_max_hz": 10}, ["control_panel"], ["measurement.integral_hz"], "对已观察到的合成频谱幅度执行梯形积分,不使用样品真值。", "已有完整扫描,积分下限小于上限,且整个区间在已采谱范围内。")}
caps = {}
error_texts = {"UNKNOWN_INSTANCE": "实例不可用。", "UNKNOWN_CAPABILITY": "能力不可用。", "INVALID_ARGUMENT": "参数结构、类型或有限数值范围无效。", "ACCESS_DENIED": "访问策略拒绝。", "PRECONDITION_FAILED": "样品、方法或运行状态前提未满足。", "BUSY": "采集正在运行。", "UNSUPPORTED": "当前模型未实现所选解耦或梯度功能。", "REQUEST_CONFLICT": "同一请求标识被用于不同参数。", "DEVICE_ERROR": "场景适配器失败;过程未提交,外部场景可能已有部分变化。"}
for name, (kind, inp, out, ex, components, effects, description, pre) in defs.items():
scene = any(k in SPINSOLVE80_SCENE_KEYS for k in effects)
caps[name] = {"function_zh": description, "kind": kind, "visibility": "agent", "component_ids": components, "availability": "implemented",
"input_schema": _sp80_obj(inp), "output_schema": _sp80_obj(out),
"implementation": {"process": "implemented", "scene": "declared" if scene else "not_applicable", "robot": "absent", "hardware": "absent", "host": "implemented"},
"binding": {"backend": "process", "artifact_id": "runtime_code", "entrypoint": "MagritekSpinsolve80Session.invoke", "invocation": "session.invoke(instance_id='spinsolve_01', capability_id='" + name + "', arguments=" + repr(ex) + ", request_id='unique_request')"},
"preconditions": [{"description_zh": pre, "state_ids": [], "enforced_by": "runtime", "check": "MagritekSpinsolve80Session._checked validates schema and preconditions before committing."}],
"state_effects": [{"state_id": k, "description_zh": description, "timing": "immediate"} for k in dict.fromkeys(effects)],
"observes": [k for k in effects if k != "measurement.synthetic"],
"model_effects": {"mode": "host_required" if scene else "none", "binding_ids": [], "description_zh": "可选scene_adapter接收六个允许的场景键;实际几何求值另验。" if scene else "纯查询或数值分析,无可见几何变化。"},
"execution": {"mode": "synchronous", "time_domain": "simulation", "completion_criterion": "命令同步提交;acquisition.start只表示计划启动,完成须宿主推进至acquisition.status=completed。", "completion_state_ids": ["acquisition.status"] if name.startswith("acquisition.") else [], "timeout_s": None, "cancellation": "unsupported", "retry": "same_request_id", "resources": ["instance.acquisition"], "partial_failure_zh": "拒绝不改过程;scene_adapter失败可能留下外部场景部分效果。acquisition.stop保留已完成扫描。"},
"errors": [{"code": code, "meaning_zh": text, "side_effects": "unknown" if code == "DEVICE_ERROR" else "none"} for code, text in error_texts.items()], "example_arguments": [ex], "verification": []}
def prop(value, unit, evidence, text):
return {"value": value, "unit": unit, "meaning_zh": text, "evidence": evidence, "source_ids": ["workbook_parameters"] if evidence == "documented" else ["runtime_code"], "uncertainty": None}
parameters = {"proton_carrier_frequency_hz": prop(80e6, "Hz", "documented", "清单1H频率80MHz;不代表部件工作响应。"),
"carbon_carrier_frequency_hz": prop(None, "Hz", "unknown", "清单未给13C载频,保持null。"), "fwhm_specification_hz": prop(0.4, "Hz", "documented", "Classic整机半高线宽严格小于0.4Hz;不用于生成合成T2。"),
"tail_linewidth_specification_hz": prop(16, "Hz", "documented", "Classic整机0.55%峰高线宽严格小于16Hz;不作为合成响应参数。"), "sensitivity_ratio_lower_bound": prop(200, "1", "documented", "整机双通道1H灵敏度>200:1,条件1%乙苯;未实现噪声与灵敏度验证。"),
"max_points": prop(512, "1", "assumption", "engineering_assumption:本Python DFT计算资源上限,不是厂商规格。")}
for name, unit in (("manufacturer_pulse_duration_s", "s"), ("manufacturer_t1_s", "s"), ("manufacturer_t2_s", "s"), ("noise_amplitude", "1"), ("calibration_accuracy_hz", "Hz"), ("fault_probability", "1")):
parameters[name] = prop(None, unit, "unknown", "清单未提供真实响应证据;保持null。")
limitations = ["所有FID、1D频谱与数值积分均为synthetic;工程假设教学模型不能声称复现Spinsolve响应、Classic线宽、灵敏度或真实测量。", "只实现1H/13C单脉冲1D、宿主显式扫描计时与无噪声平均;2D、耦合多重峰自动求解、解耦、梯度、结构约束、定量核磁、真实校准与故障概率未实现。", "每扫描耗时=用户弛豫延迟+用户采集时间;不模拟T1饱和恢复、脉冲时宽、接收器死区、磁场漂移或厂商固件。", "幅度任意且无量纲,积分单位Hz;积分不是浓度或核数。13C载频未知,不输出ppm横轴。", "样品槽仅逻辑关联;插入占比为示意映射,不执行机器人插入、接触或真实磁场作用。", "注册样品、共同绝对时钟由可信宿主管理;公开session过滤是API边界,不是同进程Python或文件系统沙箱。请求幂等缓存仅在内存中。", "可选scene_adapter失败时过程不提交;外部场景可能已部分修改,需宿主协调恢复。"]
mechanisms = {"synthetic_nmr_signal": {"component_ids": ["magnet_module", "sample_port"], "state_ids": ["truth.registered_samples", "method.nucleus", "method.acquisition_time_s", "method.points", "measurement.fid", "measurement.spectrum", "measurement.integral_hz"], "meaning_zh": "engineering_assumption:阻尼复正弦合成FID、归一化DFT和观测频带积分;全部输出synthetic。", "implementation": "numerical", "equations": ["FID[n]=sum(A_j*exp(-t_n/T2_j)*exp(i*2*pi*f_j*t_n)); t_n=n*T_acq/N", "S[k]=sum(FID[n]*exp(-i*2*pi*k*n/N))/N; f_k=(k-floor(N/2))/T_acq", "integral=piecewise-linear trapezoid integral of abs(S) over explicit observed frequency interval"], "parameters": parameters, "source_ids": ["runtime_code", "workbook_parameters"], "limitations": limitations[:4]},
"host_timed_scanning": {"component_ids": ["magnet_module", "control_panel"], "state_ids": ["method.scans", "method.relaxation_delay_s", "method.acquisition_time_s", "acquisition.elapsed_s", "acquisition.completed_scans", "acquisition.progress", "acquisition.status"], "meaning_zh": "engineering_assumption:由共享宿主绝对时钟推进离散完整扫描。", "implementation": "numerical", "equations": ["cycle=T_relax+T_acq; completed_scans=min(scans,floor((host_time-start_time)/cycle)); progress=min(1,elapsed/(scans*cycle))"], "parameters": {}, "source_ids": ["runtime_code"], "limitations": ["无自动世界推进;read/describe/query不推进时钟。", "未完成扫描不产生伪完整谱;取消保留已完成扫描。"]}}
return {"asset_types": {SPINSOLVE80_TYPE: {"catalog_id": "CHEM-068", "model": "Magritek | Spinsolve 80 Carbon", "asset_version": "1.1.0", "state_slots": slots, "capabilities": caps, "parameters": parameters}}, "mechanisms": mechanisms, "scene_snapshot_keys": list(SPINSOLVE80_SCENE_KEYS), "limitations": limitations,
"host_capabilities": {"sim.host_step": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "MagritekSpinsolve80Runtime.host_step(time_s)", "state_effects": reset}, "sim.register_sample": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "MagritekSpinsolve80Runtime.register_sample(instance_id, sample_id, signals)", "state_effects": ["truth.registered_samples"]}}, "host_sample_schema": fixture}
class MagritekSpinsolve80Runtime:
"""Trusted host. Distribute a scoped Session to agents, never this object."""
def __init__(self, *, scene_adapter=None):
self.time_s, self.scene_adapter = 0.0, scene_adapter
self._instances, self._principals, self._requests, self._logs = {}, {}, {}, {}
self._lock = _sp80_threading.RLock()
self._metadata = export_magritek_spinsolve80_contract_metadata()
self.register_principal("__public_agent__", visibility="agent")
self._agent = self.session("__public_agent__")
def create_instance(self, instance_id, asset_type_id=SPINSOLVE80_TYPE):
with self._lock:
if not isinstance(instance_id, str) or not 1 <= len(instance_id) <= 128 or instance_id in self._instances or asset_type_id != SPINSOLVE80_TYPE:
raise ValueError("Unique instance id and supported asset type required")
inst = {"revision": 0, "power": False, "sample_id": None, "method": None, "samples": {}}
self._reset(inst)
if self.scene_adapter:
self.scene_adapter(instance_id, self._scene(inst))
self._instances[instance_id] = inst
@staticmethod
def _reset(inst):
inst.update({"running": False, "status": "idle", "progress": 0.0, "completed_scans": 0, "elapsed": 0.0, "started_at": None, "sample_time": None, "fid": [], "spectrum": [], "integral": None})
def register_principal(self, principal_id, *, visibility, instance_ids=None):
with self._lock:
if not isinstance(principal_id, str) or not principal_id or principal_id in self._principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Invalid trusted principal registration")
if instance_ids is not None and (not isinstance(instance_ids, (list, tuple, set, frozenset)) or any(not isinstance(i, str) for i in instance_ids)):
raise ValueError("Invalid instance scope")
scope = None if instance_ids is None else frozenset(instance_ids)
if scope is not None and not scope <= self._instances.keys():
raise ValueError("Unknown instance scope")
self._principals[principal_id], self._logs[principal_id] = (visibility, scope), []
def session(self, principal_id):
if principal_id not in self._principals:
raise ValueError("Trusted registration required")
return MagritekSpinsolve80Session(self, principal_id)
def describe(self, **kwargs):
return self._agent.describe(**kwargs)
def read(self, **kwargs):
return self._agent.read(**kwargs)
def invoke(self, **kwargs):
return self._agent.invoke(**kwargs)
def write(self, **kwargs):
return self._agent.write(**kwargs)
def describe_host(self):
return _sp80_copy.deepcopy(self._metadata["host_capabilities"])
def register_sample(self, instance_id, sample_id, signals):
with self._lock:
if instance_id not in self._instances or not isinstance(sample_id, str) or not 1 <= len(sample_id) <= 128 or not _sp80_matches(self._metadata["host_sample_schema"], signals):
raise ValueError("Invalid instance, sample identifier or finite synthetic signal schema")
inst = self._instances[instance_id]
if sample_id in inst["samples"] or len(inst["samples"]) >= 64 or inst["running"]:
raise ValueError("Sample registration unavailable")
inst["samples"][sample_id] = _sp80_copy.deepcopy(signals)
inst["revision"] += 1
@staticmethod
def _display(inst):
return "SYNTHETIC " + ("OFF" if not inst["power"] else inst["status"].upper()) + " %d SCANS" % inst["completed_scans"]
@classmethod
def _scene(cls, inst):
return {"power.enabled": inst["power"], "slot.sample_tube.connection_id": inst["sample_id"], "sample.insertion_fraction": 1.0 if inst["sample_id"] is not None else 0.0, "acquisition.running": inst["running"], "acquisition.progress": inst["progress"], "display.text": cls._display(inst)}
def scene_snapshot(self, instance_id):
with self._lock:
return _sp80_copy.deepcopy(self._scene(self._instances[instance_id]))
def apply_scene(self, instance_id):
with self._lock:
if self.scene_adapter is None:
raise RuntimeError("No scene_adapter is configured")
snapshot = self.scene_snapshot(instance_id)
self.scene_adapter(instance_id, _sp80_copy.deepcopy(snapshot))
return snapshot
@classmethod
def _values(cls, inst):
values = cls._scene(inst)
config = inst["method"] or {}
for key in ("nucleus", "pulse_sequence", "scans", "relaxation_delay_s", "acquisition_time_s", "points", "decoupling", "gradient_enabled"):
values["method." + key] = config.get(key)
values.update({"method.carrier_frequency_hz": 80e6 if config.get("nucleus") == "1H" else None, "acquisition.status": inst["status"], "acquisition.completed_scans": inst["completed_scans"], "acquisition.elapsed_s": inst["elapsed"], "measurement.sample_time_s": inst["sample_time"], "measurement.synthetic": True, "measurement.fid": inst["fid"], "measurement.spectrum": inst["spectrum"], "measurement.integral_hz": inst["integral"], "truth.registered_samples": [{"sample_id": k, "signals": v} for k, v in sorted(inst["samples"].items()) if k not in inst.get("template_samples", {})]})
return _sp80_copy.deepcopy(values)
@staticmethod
def _signal(inst):
method = inst["method"]
n, duration = method["points"], method["acquisition_time_s"]
peaks = inst["samples"][inst["sample_id"]][method["nucleus"]]
samples, fid = [], []
for j in range(n):
t = j * duration / n
y = sum(p["amplitude"] * _sp80_cmath.exp(complex(-t / p["t2_s"], 2 * _sp80_math.pi * p["frequency_offset_hz"] * t)) for p in peaks)
samples.append(y)
fid.append({"time_s": t, "real": y.real, "imaginary": y.imag, "synthetic": True})
spectrum = []
for k in range(-(n // 2), n - n // 2):
value = sum(samples[j] * _sp80_cmath.exp(-2j * _sp80_math.pi * k * j / n) for j in range(n)) / n
spectrum.append({"frequency_offset_hz": k / duration, "real": value.real, "imaginary": value.imag, "amplitude": abs(value), "synthetic": True})
return fid, spectrum
def host_step(self, time_s):
"""Advance this host's registered instances to shared absolute SI time."""
with self._lock:
if not _sp80_number(time_s) or time_s < self.time_s:
raise ValueError("Finite monotonic absolute host time required")
if time_s == self.time_s:
return
staged = {}
for instance_id, old in self._instances.items():
if not old["running"]:
continue
new = _sp80_copy.deepcopy(old)
cfg = new["method"]
cycle = cfg["relaxation_delay_s"] + cfg["acquisition_time_s"]
total = cfg["scans"] * cycle
elapsed = time_s - new["started_at"]
if not _sp80_number(elapsed):
raise ValueError("Host interval is not numerically representable")
new["elapsed"] = min(elapsed, total)
new["progress"] = new["elapsed"] / total
count = cfg["scans"] if elapsed >= total else min(cfg["scans"], int(elapsed / cycle))
if count > old["completed_scans"]:
if not old["fid"]:
new["fid"], new["spectrum"] = self._signal(new)
new["completed_scans"] = count
new["sample_time"] = new["started_at"] + count * cycle
new["integral"] = None
if count == cfg["scans"]:
new["running"], new["status"] = False, "completed"
new["revision"] = old["revision"] + 1
staged[instance_id] = new
if self.scene_adapter:
for iid, new in staged.items():
if self._scene(new) != self._scene(self._instances[iid]):
self.scene_adapter(iid, self._scene(new))
self._instances.update(staged)
self.time_s = float(time_s)
class MagritekSpinsolve80Session:
"""Permission-scoped API view; not a Python object-capability sandbox."""
def __init__(self, host, principal_id):
self.__host, self.__principal = host, principal_id
def _instance(self, instance_id):
_, scope = self.__host._principals[self.__principal]
return self.__host._instances.get(instance_id) if isinstance(instance_id, str) and (scope is None or instance_id in scope) else None
def _visible(self, slot):
return slot["visibility"] == "agent" or self.__host._principals[self.__principal][0] in ("debug", "evaluator")
def _envelope(self, instance_id, request_id=None, *, status="succeeded", result=None, observations=None, error=None):
inst = self._instance(instance_id)
return {"protocol_version": "1.0.0", "instance_id": instance_id, "request_id": request_id, "operation_id": None, "status": status, "state_revision": inst["revision"] if inst else None, "clock": {"domain": "simulation", "time_s": self.__host.time_s}, "result": _sp80_copy.deepcopy(result or {}), "observations": _sp80_copy.deepcopy(observations or {}), "error": error}
def _error(self, instance_id, code, request_id=None):
return self._envelope(instance_id, request_id, status="failed" if code == "DEVICE_ERROR" else "rejected", error={"code": code, "message": "Request unavailable under current arguments, state or access policy." if code != "DEVICE_ERROR" else "External scene synchronization failed; process not committed.", "retryable": False, "side_effects": "unknown" if code == "DEVICE_ERROR" else "none", "progress": None})
def describe(self, *, asset_type_id=None, instance_id=None):
with self.__host._lock:
if (asset_type_id is None) == (instance_id is None) or (asset_type_id is not None and asset_type_id != SPINSOLVE80_TYPE):
return self._error(instance_id, "INVALID_ARGUMENT")
if instance_id is not None and self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
_, scope = self.__host._principals[self.__principal]
if scope is not None and not scope:
return self._error(instance_id, "ACCESS_DENIED")
spec = _sp80_copy.deepcopy(self.__host._metadata["asset_types"][SPINSOLVE80_TYPE])
spec["state_slots"] = {k: v for k, v in spec["state_slots"].items() if self._visible(v)}
spec["capabilities"].update(_sp80_template_module().capability_metadata()) # template-backed sample queries (additive)
return {"protocol_version": "1.0.0", "asset_type_id": SPINSOLVE80_TYPE, "instance_id": instance_id, "adapter": "basic40_runtime_measure.MagritekSpinsolve80Session", **spec, "limitations": _sp80_copy.deepcopy(self.__host._metadata["limitations"])}
def read(self, *, instance_id, state_ids=None):
with self.__host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
slots = self.__host._metadata["asset_types"][SPINSOLVE80_TYPE]["state_slots"]
if state_ids is None:
state_ids = [k for k, s in slots.items() if self._visible(s)]
if not isinstance(state_ids, list) or any(not isinstance(k, str) for k in state_ids) or len(set(state_ids)) != len(state_ids):
return self._error(instance_id, "INVALID_ARGUMENT")
if any(k not in slots or not self._visible(slots[k]) for k in state_ids):
return self._error(instance_id, "ACCESS_DENIED")
values = self.__host._values(inst)
observations = {k: {"value": values[k], "unit": slots[k]["unit"], "quality": "unavailable" if values[k] is None else "estimated" if slots[k]["origin"] == "derived" else "valid", "sample_time_s": inst["sample_time"] if k.startswith("measurement.") else self.__host.time_s, "sample_window_s": None, "synthetic": slots[k]["origin"] == "derived", "reason": "No available configured or synthetic value." if values[k] is None else None} for k in state_ids}
return self._envelope(instance_id, observations=observations)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
if not isinstance(capability_id, str) or not isinstance(arguments, dict) or not isinstance(request_id, str) or not 1 <= len(request_id) <= 256:
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
try:
digest = _sp80_hashlib.sha256(_sp80_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False).encode()).hexdigest()
except (TypeError, ValueError, OverflowError):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
key = self.__principal, instance_id, request_id
if key in host._requests:
old_digest, response = host._requests[key]
return _sp80_copy.deepcopy(response) if old_digest == digest else self._error(instance_id, "REQUEST_CONFLICT", request_id)
response = self._checked(instance_id, inst, capability_id, arguments, request_id)
host._requests[key] = digest, _sp80_copy.deepcopy(response)
host._logs[self.__principal].append({"instance_id": instance_id, "capability_id": capability_id, "request_id": request_id, "response": _sp80_copy.deepcopy(response)})
return response
def _checked(self, instance_id, inst, cap, args, request_id):
host = self.__host
if cap in ("template.read", "nmr.read_template_spectrum"): # additive template-backed queries (read-only)
return _sp80_template_module().session_query(self, host, instance_id, inst, cap, args, request_id)
definition = host._metadata["asset_types"][SPINSOLVE80_TYPE]["capabilities"].get(cap)
if definition is None:
return self._error(instance_id, "UNKNOWN_CAPABILITY", request_id)
if not _sp80_matches(definition["input_schema"], args):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
if cap == "acquisition.configure" and (args["decoupling"] or args["gradient_enabled"]):
return self._error(instance_id, "UNSUPPORTED", request_id)
if inst["running"] and cap in ("sample.insert", "sample.remove", "acquisition.configure", "acquisition.start"):
return self._error(instance_id, "BUSY", request_id)
if cap == "sample.insert" and (inst["sample_id"] is not None or args["sample_id"] not in inst["samples"]):
return self._error(instance_id, "PRECONDITION_FAILED", request_id)
if cap == "acquisition.start":
cfg = inst["method"]
if not inst["power"] or inst["sample_id"] is None or cfg is None:
return self._error(instance_id, "PRECONDITION_FAILED", request_id)
signals = inst["samples"][inst["sample_id"]][cfg["nucleus"]]
nyquist = cfg["points"] / cfg["acquisition_time_s"] / 2
if not signals or any(abs(p["frequency_offset_hz"]) >= nyquist for p in signals) or host.time_s + cfg["scans"] * (cfg["relaxation_delay_s"] + cfg["acquisition_time_s"]) <= host.time_s:
return self._error(instance_id, "PRECONDITION_FAILED", request_id)
if cap == "nmr.integrate":
a, b, spectrum = args["frequency_min_hz"], args["frequency_max_hz"], inst["spectrum"]
if not spectrum or not spectrum[0]["frequency_offset_hz"] <= a < b <= spectrum[-1]["frequency_offset_hz"]:
return self._error(instance_id, "PRECONDITION_FAILED", request_id)
new = _sp80_copy.deepcopy(inst)
if cap == "power.set":
new["power"] = args["enabled"]
if not new["power"] and new["running"]:
new["running"], new["status"] = False, "stopped"
result = {"enabled": new["power"]}
elif cap in ("sample.insert", "sample.remove"):
old_id = new["sample_id"]
new["sample_id"] = args["sample_id"] if cap == "sample.insert" else None
host._reset(new)
result = {"sample_id": new["sample_id"] if cap == "sample.insert" else old_id, "insertion_fraction": 1.0 if new["sample_id"] is not None else 0.0}
elif cap == "acquisition.configure":
new["method"] = _sp80_copy.deepcopy(args)
host._reset(new)
result = _sp80_copy.deepcopy(args)
elif cap == "acquisition.start":
host._reset(new)
new.update({"running": True, "status": "running", "started_at": host.time_s})
result = {"status": "running", "synthetic": True}
elif cap == "acquisition.stop":
if new["running"]:
new["running"], new["status"] = False, "stopped"
result = {"status": new["status"], "completed_scans": new["completed_scans"], "synthetic": True}
elif cap == "nmr.read_fid":
result = {"samples": new["fid"], "completed_scans": new["completed_scans"], "status": new["status"], "synthetic": True}
elif cap == "nmr.read_spectrum":
result = {"samples": new["spectrum"], "nucleus": (new["method"] or {}).get("nucleus"), "carrier_frequency_hz": host._values(new)["method.carrier_frequency_hz"], "status": new["status"], "synthetic": True}
elif cap == "nmr.integrate":
integral = 0.0
for p, q in zip(spectrum, spectrum[1:]):
x0, x1 = p["frequency_offset_hz"], q["frequency_offset_hz"]
lo, hi = max(x0, a), min(x1, b)
if hi <= lo:
continue
y0, y1 = p["amplitude"], q["amplitude"]
yl, yh = y0 + (y1 - y0) * (lo - x0) / (x1 - x0), y0 + (y1 - y0) * (hi - x0) / (x1 - x0)
integral += (yl + yh) * (hi - lo) / 2
new["integral"] = integral
result = {"integral_hz": integral, "synthetic": True}
if new != inst:
new["revision"] = inst["revision"] + 1
if host.scene_adapter and host._scene(new) != host._scene(inst):
try:
host.scene_adapter(instance_id, host._scene(new))
except Exception:
return self._error(instance_id, "DEVICE_ERROR", request_id)
host._instances[instance_id] = new
return self._envelope(instance_id, request_id, result=result)
def write(self, *, instance_id, state_id, value, request_id):
if state_id != "power.enabled":
return self._error(instance_id, "ACCESS_DENIED", request_id)
return self.invoke(instance_id=instance_id, capability_id="power.set", arguments={"enabled": value}, request_id=request_id)
def logs(self):
with self.__host._lock:
return _sp80_copy.deepcopy(self.__host._logs[self.__principal])
def write_magritek_spinsolve80_runtime_reports(output_directory):
"""Write static type information only; never export instance sample truth."""
directory = _sp80_Path(output_directory)
directory.mkdir(parents=True, exist_ok=True)
metadata = export_magritek_spinsolve80_contract_metadata()
(directory / "runtime_metadata.json").write_text(_sp80_json.dumps(metadata, ensure_ascii=False, indent=2) + "\n", encoding="utf-8")
return {"metadata": str(directory / "runtime_metadata.json"), "catalog_id": "CHEM-068", "test_status": "not_run_by_report_writer", "generated_at": _sp80_datetime.now(_sp80_timezone.utc).isoformat()}
# END CHEM-068 MAGRITEK SPINSOLVE 80 APPEND-ONLY RUNTIME
# CHEM-068 append-only contract normalization and exact decimal scan scheduling.
from decimal import Decimal as _sp80_Decimal
_sp80_export_contract_base = export_magritek_spinsolve80_contract_metadata
def export_magritek_spinsolve80_contract_metadata():
metadata = _sp80_export_contract_base()
specs = metadata["asset_types"][SPINSOLVE80_TYPE]["capabilities"]
observes = {
"power.set": ["power.enabled"],
"sample.insert": ["slot.sample_tube.connection_id", "sample.insertion_fraction"],
"sample.remove": ["slot.sample_tube.connection_id", "sample.insertion_fraction"],
"acquisition.configure": ["method." + k for k in specs["acquisition.configure"]["input_schema"]["properties"]],
"acquisition.start": ["acquisition.status", "measurement.synthetic"],
"acquisition.stop": ["acquisition.status", "acquisition.completed_scans", "measurement.synthetic"],
"nmr.read_fid": ["measurement.fid", "acquisition.completed_scans", "acquisition.status", "measurement.synthetic"],
"nmr.read_spectrum": ["measurement.spectrum", "method.nucleus", "method.carrier_frequency_hz", "acquisition.status", "measurement.synthetic"],
"nmr.integrate": ["measurement.integral_hz", "measurement.synthetic"]}
for name, spec in specs.items():
spec["example_arguments"] = spec["example_arguments"][0]
spec["source_ids"] = ["runtime_code"]
spec["limitations"] = ["synthetic工程假设;未执行真实仪器、机器人或接触验证。"]
spec["observes"] = observes[name]
metadata["mechanisms"]["synthetic_nmr_signal"]["equations"][1] = "S[k]=sum(FID[n]*exp(-i*2*pi*k*n/N))/N; k=-floor(N/2)..N-floor(N/2)-1; f_k=k/T_acq"
metadata["mechanisms"]["host_timed_scanning"]["limitations"].append("扫描边界以十进制输入时间计算,避免0.3/0.1等二进制舍入导致漏计扫描;信号与进度为浮点近似。")
return metadata
def _sp80_host_step_decimal(self, time_s):
"""Host-only absolute time: decimal scan boundaries, no query-side stepping."""
with self._lock:
if not _sp80_number(time_s) or time_s < self.time_s:
raise ValueError("Finite monotonic absolute host time required")
if time_s == self.time_s:
return
staged = {}
now = _sp80_Decimal(str(time_s))
for iid, old in self._instances.items():
if not old["running"]:
continue
new, cfg = _sp80_copy.deepcopy(old), old["method"]
start = _sp80_Decimal(str(new["started_at"]))
cycle = _sp80_Decimal(str(cfg["relaxation_delay_s"])) + _sp80_Decimal(str(cfg["acquisition_time_s"]))
total = cfg["scans"] * cycle
elapsed = now - start
bounded = min(elapsed, total)
count = cfg["scans"] if elapsed >= total else int(elapsed // cycle)
new["elapsed"], new["progress"] = float(bounded), float(bounded / total)
if count > old["completed_scans"]:
if not old["fid"]:
new["fid"], new["spectrum"] = self._signal(new)
new["completed_scans"] = count
new["sample_time"] = float(start + count * cycle)
new["integral"] = None
if count == cfg["scans"]:
new["running"], new["status"] = False, "completed"
new["revision"] = old["revision"] + 1
staged[iid] = new
if self.scene_adapter:
for iid, new in staged.items():
if self._scene(new) != self._scene(self._instances[iid]):
self.scene_adapter(iid, self._scene(new))
self._instances.update(staged)
self.time_s = float(time_s)
MagritekSpinsolve80Runtime.host_step = _sp80_host_step_decimal
# Remove unused sentinel from the first append without rewriting shared content.
del MAGRIΤEK_SPINSOLVE80_RESERVED
# CHEM-068 template-backed samples (HMDB peak lists, scripts/basic40_templates/magritek_spinsolve80.py); host-only, additive.
def _sp80_template_module():
"""Lazy import of the public-data NMR template extension."""
try:
from .basic40_templates import magritek_spinsolve80 as module
except ImportError:
from basic40_templates import magritek_spinsolve80 as module
return module
def _sp80_register_template_sample(self, instance_id, sample_id, composition, *, solvent=None):
_sp80_template_module().register_template_sample(self, instance_id, sample_id, composition, solvent=solvent)
def _sp80_template_sample_truth(self, instance_id):
return _sp80_template_module().template_sample_truth(self, instance_id)
MagritekSpinsolve80Runtime.register_template_sample = _sp80_register_template_sample
MagritekSpinsolve80Runtime.template_sample_truth = _sp80_template_sample_truth
# BEGIN CHEM-160 RIGAKU MINIFLEX600 APPEND-ONLY RUNTIME
import copy as _mf_copy
import hashlib as _mf_hashlib
import json as _mf_json
import math as _mf_math
import threading as _mf_threading
RIGAKU_MINIFLEX600_TYPE = "instrument.rigaku_miniflex600_external_cooling"
RIGAKU_MINIFLEX600_MIN_RAD = _mf_math.radians(-3)
RIGAKU_MINIFLEX600_MAX_RAD = _mf_math.radians(145)
RIGAKU_MINIFLEX600_STEP_RAD = _mf_math.radians(0.005)
RIGAKU_MINIFLEX600_DOOR_MAX_RAD = _mf_math.pi / 2
RIGAKU_MINIFLEX600_MAX_POINTS = 29601
def _mf_number(v):
try:
return type(v) in (int, float) and _mf_math.isfinite(v)
except (TypeError, ValueError, OverflowError):
return False
def _mf_num(unit, lo=None, hi=None, nullable=False, positive=False):
s = {"type": "number", "x-unit": unit}
if lo is not None:
s["minimum"] = lo
if hi is not None:
s["maximum"] = hi
if positive:
s["exclusiveMinimum"] = 0
return {"anyOf": [s, {"type": "null"}]} if nullable else s
def _mf_obj(properties):
return {"type": "object", "properties": properties, "required": list(properties), "additionalProperties": False}
def _mf_matches(s, v):
if "anyOf" in s:
return any(_mf_matches(branch, v) for branch in s["anyOf"])
typ = s.get("type")
if typ == "null":
return v is None
if typ == "object":
return isinstance(v, dict) and set(v) == set(s["properties"]) and all(_mf_matches(s["properties"][k], x) for k, x in v.items())
if typ == "array":
return isinstance(v, list) and s.get("minItems", 0) <= len(v) <= s.get("maxItems", len(v)) and all(_mf_matches(s["items"], x) for x in v)
if typ in ("number", "integer"):
if not _mf_number(v) or (typ == "integer" and type(v) is not int):
return False
if ("minimum" in s and v < s["minimum"]) or ("maximum" in s and v > s["maximum"]) or ("exclusiveMinimum" in s and v <= s["exclusiveMinimum"]):
return False
elif typ == "boolean":
if type(v) is not bool:
return False
elif typ == "string":
if not isinstance(v, str) or len(v) < s.get("minLength", 0) or len(v) > s.get("maxLength", len(v)):
return False
else:
return False
return ("enum" not in s or v in s["enum"]) and ("const" not in s or v == s["const"])
def _mf_grid(value, quantum):
ratio = value / quantum
return _mf_number(ratio) and abs(ratio - round(ratio)) <= 1e-7
def export_rigaku_miniflex600_contract_metadata():
"""Static catalogue, API and approximation metadata; contains no instance truth."""
boolean, synthetic = {"type": "boolean"}, {"type": "boolean", "const": True}
ident = {"type": "string", "minLength": 1, "maxLength": 256}
nullable_id = {"anyOf": [ident, {"type": "null"}]}
angle = _mf_num("rad", RIGAKU_MINIFLEX600_MIN_RAD, RIGAKU_MINIFLEX600_MAX_RAD)
status = {"type": "string", "enum": ["idle", "running", "completed", "stopped", "cooling_lost", "power_lost"]}
response_point = _mf_obj({"two_theta_rad": angle, "intensity_cps": _mf_num("1/s", 0)})
response = {"type": "array", "items": response_point, "minItems": 2, "maxItems": RIGAKU_MINIFLEX600_MAX_POINTS}
point = _mf_obj({"two_theta_rad": angle, "intensity_cps": _mf_num("1/s", 0), "expected_counts": _mf_num("1", 0),
"sample_time_s": _mf_num("s", 0), "integration_time_s": _mf_num("s", positive=True),
"sample_window_s": {"type": "array", "items": _mf_num("s", 0), "minItems": 2, "maxItems": 2}, "synthetic": synthetic})
pattern = {"type": "array", "items": point, "maxItems": RIGAKU_MINIFLEX600_MAX_POINTS}
slots = {}
def route(capability, parameter):
return {"capability_id": capability, "parameter": parameter, "fixed_arguments": {}}
def slot(sid, unit, origin, schema, text, component, write=None, visibility="agent", sampling="instant"):
slots[sid] = {"description_zh": text, "unit": unit, "origin": origin, "value_schema": schema, "component_ids": [component],
"visibility": visibility, "access": "read_write" if write else "read_only", "write_via": write,
"read_binding": "RigakuMiniFlex600Session.read(instance_id=..., state_ids=[state_id])",
"sampling": {"mode": sampling, "time_domain": "simulation", "window": "Each pattern point retains its explicit integration window." if sampling == "series" else "Last completed integration interval; returned as sample_window_s." if sampling == "interval_mean" else None},
"reference_conditions": "SI rad; instrument-local joint convention, +Z up." if unit == "rad" else None}
slot("power.enabled", "1", "setpoint", boolean, "逻辑供电;非真实高压电源控制。", "housing", route("power.set", "enabled"))
slot("access.door_angle_rad", "rad", "scene", _mf_num("rad", 0, RIGAKU_MINIFLEX600_DOOR_MAX_RAD), "门关节;0为关闭,π/2展示上限为engineering_assumption。", "door", route("access.set_door_angle", "angle_rad"))
slot("slot.sample.connection_id", "1", "scene", nullable_id, "粉末平片或适配样品架的逻辑槽占用,不执行机器人插拔。", "sample_holder", route("slot.set_sample", "connection_id"))
slot("cooling.connection_id", "1", "scene", nullable_id, "外置循环水依赖连接,只可由宿主登记。", "cooling_ports")
slot("cooling.ready", "1", "derived", boolean, "宿主明确提供的循环水就绪信号,未模拟水温/流量传感器。", "cooling_ports")
slot("xray.voltage_v", "V", "setpoint", _mf_num("V", 20000, 40000, True), "20–40kV,1kV步长,尚未设置时null。", "xray_tube")
slot("xray.current_a", "A", "setpoint", _mf_num("A", 0.002, 0.015, True), "2–15mA,1mA步长,尚未设置时null。", "xray_tube")
slot("xray.power_w", "W", "derived", _mf_num("W", 0, 600, True), "设定管压×管流;600W为整机管源最大输出约束。", "xray_tube")
slot("xray.active", "1", "derived", boolean, "仅扫描时为真的逻辑射线使能;不模拟辐射场或屏蔽性能。", "xray_tube")
slot("slit.configuration_id", "1", "setpoint", nullable_id, "显式方法狭缝标签;数值孔径未知,未计算其展宽效应。", "slit_assembly", route("xrd.set_slit", "slit_id"))
slot("goniometer.two_theta_rad", "rad", "scene", angle, "2θ权威机械角,范围−3..145°、量化0.005°后以rad公开。", "goniometer", route("motion.set_two_theta", "angle_rad"))
slot("goniometer.sample_theta_rad", "rad", "derived", _mf_num("rad", RIGAKU_MINIFLEX600_MIN_RAD / 2, RIGAKU_MINIFLEX600_MAX_RAD / 2), "θ=2θ/2是engineering_assumption的理想耦合展示。", "sample_holder")
for key, unit, text, schema in (("start_rad", "rad", "起点", {"anyOf": [angle, {"type": "null"}]}), ("stop_rad", "rad", "终点", {"anyOf": [angle, {"type": "null"}]}),
("step_rad", "rad", "步长", _mf_num("rad", RIGAKU_MINIFLEX600_STEP_RAD, nullable=True)), ("integration_time_s", "s", "显式积分时间,厂家范围未知", _mf_num("s", nullable=True, positive=True))):
slot("scan." + key, unit, "setpoint", schema, "用户配置扫描" + text + "。", "goniometer")
slot("scan.running", "1", "derived", boolean, "开始调用只置运行标志;采集仅在host_step推进。", "detector")
slot("scan.status", "1", "derived", status, "完成仅表示合成插值扫描已采集所有方法点。", "detector")
for name, text in (("completed_points", "已完成采集点数"), ("total_points", "配置方法的点数")):
slot("scan." + name, "1", "derived", {"type": "integer", "minimum": 0, "maximum": RIGAKU_MINIFLEX600_MAX_POINTS, "x-unit": "1"}, text + ";未积分完的点不计入。", "detector")
slot("measurement.pattern", "1", "derived", pattern, "仅已完成积分点的synthetic曲线;逐点含rad、1/s、期望计数与窗口,不含晶体学真实性声明。", "detector", sampling="series")
slot("measurement.last_intensity_cps", "1/s", "derived", _mf_num("1/s", 0, nullable=True), "最近完整积分窗口的synthetic平均计数率;没有数据时null。", "detector", sampling="interval_mean")
slot("measurement.synthetic", "1", "derived", synthetic, "所有输出结果均为synthetic。", "detector")
slot("truth.response", "1", "process_truth", {"anyOf": [response, {"type": "null"}]}, "宿主输入的合成响应网格,仅debug/evaluator可读。", "detector", visibility="debug")
slot("truth.sample_connection_id", "1", "process_truth", nullable_id, "宿主响应对应的样品槽身份;避免换样后沿用旧响应。", "sample_holder", visibility="debug")
scene_keys = ["power.enabled", "access.door_angle_rad", "slot.sample.connection_id", "goniometer.two_theta_rad", "goniometer.sample_theta_rad", "xray.active", "scan.running"]
reset_effects = ["scan.running", "scan.status", "scan.completed_points", "measurement.pattern", "measurement.last_intensity_cps", "xray.active"]
defs = {
"power.set": ({"enabled": boolean}, {"enabled": boolean}, {"enabled": True}, ["power.enabled", "scan.running", "scan.status", "xray.active"], ["housing", "xray_tube"], "设置逻辑电源;断电终止扫描并保留完整积分点。", [], "实例可用。"),
"access.set_door_angle": ({"angle_rad": _mf_num("rad", 0, RIGAKU_MINIFLEX600_DOOR_MAX_RAD)}, {"angle_rad": _mf_num("rad")}, {"angle_rad": 0.5}, ["access.door_angle_rad"], ["door"], "设置示意门角。", ["xray.active", "scan.running"], "扫描中拒绝开门;门角超出展示限位拒绝。"),
"slot.set_sample": ({"connection_id": nullable_id}, {"connection_id": nullable_id}, {"connection_id": "powder_holder_01"}, ["slot.sample.connection_id", "truth.response", "truth.sample_connection_id"] + reset_effects, ["sample_holder"], "登记样品槽连接;换样清除旧合成响应与旧曲线。", ["access.door_angle_rad", "scan.running"], "门打开且扫描停止;只登记逻辑连接。"),
"xray.configure": ({"voltage_v": _mf_num("V", 20000, 40000), "current_a": _mf_num("A", 0.002, 0.015)}, {"voltage_v": _mf_num("V"), "current_a": _mf_num("A")}, {"voltage_v": 40000, "current_a": 0.015}, ["xray.voltage_v", "xray.current_a", "xray.power_w"], ["xray_tube"], "配置管压/管流,分别验证1kV/1mA量化和600W上限。", ["scan.running"], "扫描停止。"),
"xrd.configure_scan": ({"start_rad": angle, "stop_rad": angle, "step_rad": _mf_num("rad", RIGAKU_MINIFLEX600_STEP_RAD), "integration_time_s": _mf_num("s", positive=True)}, {"start_rad": angle, "stop_rad": angle, "step_rad": _mf_num("rad"), "integration_time_s": _mf_num("s")}, {"start_rad": 0, "stop_rad": _mf_math.radians(1), "step_rad": _mf_math.radians(0.5), "integration_time_s": 1}, ["scan.start_rad", "scan.stop_rad", "scan.step_rad", "scan.integration_time_s", "scan.total_points"] + reset_effects, ["goniometer", "detector"], "配置递增等步长扫描;所有角度对0.005°网格量化,起止区间须整除步长。", ["scan.running"], "扫描停止;0.005°至全程的有限网格;积分时间须正且总时间可表示。"),
"xrd.set_slit": ({"slit_id": ident}, {"slit_id": ident}, {"slit_id": "host_selected_slit"}, ["slit.configuration_id"], ["slit_assembly"], "记录显式狭缝方法标签,不推断未知孔径。", ["scan.running"], "扫描停止。"),
"motion.set_two_theta": ({"angle_rad": angle}, {"angle_rad": angle}, {"angle_rad": _mf_math.radians(20)}, ["goniometer.two_theta_rad", "goniometer.sample_theta_rad"], ["goniometer", "sample_holder"], "设置2θ及θ/2展示耦合,无速度/加速度动态。", ["power.enabled", "access.door_angle_rad", "scan.running"], "供电、门关、扫描停止,角度符合0.005°网格。"),
"xrd.start_scan": ({}, {"status": status, "synthetic": synthetic}, {}, reset_effects + ["goniometer.two_theta_rad", "goniometer.sample_theta_rad"], ["goniometer", "sample_holder", "detector", "xray_tube", "cooling_ports", "door"], "开始合成扫描,定位起点但不推进宿主时间、不产生立即读数。", ["power.enabled", "access.door_angle_rad", "cooling.connection_id", "cooling.ready", "slot.sample.connection_id", "xray.voltage_v", "xray.current_a", "slit.configuration_id", "scan.total_points"], "门关闭、电源开启、循环水连接就绪、样品槽与对应宿主响应/全部方法参数齐备;响应覆盖整个扫描。"),
"xrd.stop_scan": ({}, {"status": status, "synthetic": synthetic}, {}, ["scan.running", "scan.status", "xray.active"], ["detector", "xray_tube"], "停止扫描,保留已完成积分点,未完成积分点丢弃。", [], "实例可用;不提供部分扫描续跑,重新start会清空先前曲线。"),
"xrd.read_pattern": ({}, {"samples": pattern, "status": status, "synthetic": synthetic}, {}, [], ["detector"], "读取现有合成曲线,不推进时间且不生成任何新点。", [], "实例可用。"),
"xrd.phase_search": ({}, {}, {}, [], ["detector"], "物相检索未实现;缺少晶体结构数据库与经过验证的响应。", [], "unsupported。"),
"xrd.refine": ({}, {}, {}, [], ["detector"], "精修未实现;未建立结构因子、仪器展宽、择优取向与计数噪声模型。", [], "unsupported。"),
}
caps = {}
for name, (inputs, outputs, example, effects, components, text, pre_states, pre) in defs.items():
unsupported = name in ("xrd.phase_search", "xrd.refine")
visible_effects = [s for s in effects if s in scene_keys]
caps[name] = {"availability": "unsupported" if unsupported else "implemented", "visibility": "agent",
"kind": "analysis" if unsupported else "query" if name == "xrd.read_pattern" else "configuration" if name in ("slot.set_sample", "xray.configure", "xrd.configure_scan", "xrd.set_slit") else "device_command",
"description_zh": text, "input_schema": _mf_obj(inputs), "output_schema": _mf_obj(outputs), "example_arguments": [example],
"state_effects": [{"state_id": s, "timing": "immediate", "description_zh": text} for s in effects],
"observes": ["measurement.pattern", "scan.status", "measurement.synthetic"] if name == "xrd.read_pattern" else [s for s in effects if not s.startswith("truth.")],
"component_ids": components, "preconditions_zh": pre, "precondition_state_ids": pre_states,
"binding": "basic40_runtime_measure.RigakuMiniFlex600Session.invoke(instance_id=..., capability_id='" + name + "', arguments=..., request_id=...)",
"completion_criterion_zh": "返回unsupported,无结果变化。" if unsupported else "同步命令已提交;扫描完成须另由host_step推进全部积分点并观察scan.status=completed。",
"partial_failure_zh": "拒绝无过程/场景变化。停止、掉电、冷却丢失保留已完成积分点,丢弃当前未完成积分。scene_adapter异常时过程不提交,但外部场景可能部分写入,需要宿主重新同步。",
"model_effects": {"mode": "host_required" if visible_effects else "none", "binding_ids": [], "description_zh": "scene_adapter接收公开场景快照;实际Blender求值由独立验证记录支撑。" if visible_effects else "配置、数据读取或未实现分析不改变几何。"},
"implementation": {"process": "absent" if unsupported else "implemented", "host": "absent" if unsupported else "implemented", "scene": "declared" if visible_effects else "not_applicable", "robot": "absent", "hardware": "absent"},
"error_codes": ["UNKNOWN_INSTANCE", "UNKNOWN_CAPABILITY", "INVALID_ARGUMENT", "ACCESS_DENIED", "PRECONDITION_FAILED", "BUSY", "REQUEST_CONFLICT", "DEVICE_ERROR", "UNSUPPORTED"], "retry": "same_request_id; in-memory only"}
def parameter(value, unit, evidence, text):
return {"value": value, "unit": unit, "meaning_zh": text, "evidence": evidence,
"source_ids": ["workbook_parameters"] if evidence == "documented" else ["runtime_code"], "uncertainty": None}
params = {
"voltage_range_v": parameter([20000, 40000], "V", "documented", "清单给定20–40kV。"),
"voltage_step_v": parameter(1000, "V", "documented", "清单给定1kV步长。"),
"current_range_a": parameter([0.002, 0.015], "A", "documented", "清单给定2–15mA。"),
"current_step_a": parameter(0.001, "A", "documented", "清单给定1mA步长。"),
"maximum_output_w": parameter(600, "W", "documented", "清单整机X射线管最大输出。"),
"goniometer_radius_m": parameter(0.15, "m", "documented", "清单给定测角仪半径150mm。"),
"two_theta_range_rad": parameter([RIGAKU_MINIFLEX600_MIN_RAD, RIGAKU_MINIFLEX600_MAX_RAD], "rad", "documented", "−3..145°换算SI。"),
"angle_quantum_rad": parameter(RIGAKU_MINIFLEX600_STEP_RAD, "rad", "documented", "0.005°最小步进;不代表角度准确度。"),
"door_display_limit_rad": parameter(RIGAKU_MINIFLEX600_DOOR_MAX_RAD, "rad", "assumption", "engineering_assumption:门限位演示上限,厂家未给实际角度。"),
"sample_theta_ratio": parameter(0.5, "1", "assumption", "engineering_assumption:理想θ–2θ展示耦合。"),
}
for key, unit in (("cooling_minimum_flow_m3_s", "m^3/s"), ("cooling_temperature_k", "K"), ("cooling_pressure_pa", "Pa"),
("slit_aperture_rad", "rad"), ("detector_quantum_efficiency", "1"), ("detector_dark_rate_cps", "1/s"),
("xray_wavelength_m", "m"), ("instrument_broadening_rad", "rad"), ("preferred_orientation", "1"),
("detector_mass_kg", "kg"), ("sample_stage_mass_kg", "kg"), ("tube_mass_kg", "kg"),
("integration_time_min_s", "s"), ("integration_time_max_s", "s"), ("motor_speed_rad_s", "rad/s"), ("actual_diffraction_response", "1/s")):
params[key] = parameter(None, unit, "unknown", "清单未提供;保留null,不将整机规格代替部件参数,不据此声明物理结果。")
limitations = ["All acquired intensities and expected counts are synthetic. The host supplies a response grid for workflow verification; no random peak generation, crystal structure calculation, phase search or refinement is implemented.",
"Linear interpolation and expected_counts=rate*integration_time are engineering_assumption. Counts are expectations, not simulated Poisson events. Tube settings and slit labels do not modify the host-supplied response; each response is valid only for the tube/slit configuration at host_load_synthetic_response.",
"Unknown manufacturer cooling, detector, response, slit aperture and motor parameters remain null. Cooling.ready is a host assertion, not a measured flow or temperature. No actual radiation, shielding or equipment safety certification is simulated.",
"Joint motion is instantaneous commanded pose; sample_theta=two_theta/2 and the 90-degree door display limit are engineering_assumption. No robot insertion, contact solver, acceleration or settling dynamics is implemented.",
"Only explicit absolute host_step advances a shared clock. read, describe and read_pattern do not advance time. Stops retain complete integration points and discard the unfinished interval; starting a new scan clears the previous pattern.",
"Session filtering is an API boundary only, not a Python/process/filesystem sandbox. Pass a scoped session to an agent; protect the trusted host and private response storage separately. No private instance truth is written to runtime report files.",
"Request deduplication is memory-local and does not survive restart. External scene callback failure can leave partial scene effects although process and clock are not committed. Evaluated geometry requires separate scene validation."]
mechanisms = {
"synthetic_scan": {"name_zh": "宿主合成响应的定时采集", "meaning_zh": "engineering_assumption:将显式宿主响应按角度线性插值,每个积分窗口仅生成确定性期望计数;不等于衍射物理模型。",
"component_ids": ["detector", "goniometer", "xray_tube"], "state_ids": ["measurement.pattern", "scan.running", "goniometer.two_theta_rad", "truth.response"],
"implementation": "numerical", "equations": ["theta_i=start+i*step; t_i=t_start+(i+1)*integration_time", "rate(theta)=piecewise_linear(host_response); expected_counts=rate*integration_time"],
"parameters": {k: params[k] for k in ("angle_quantum_rad", "actual_diffraction_response", "detector_quantum_efficiency", "instrument_broadening_rad")}, "source_ids": ["workbook_parameters", "runtime_code"], "limitations": limitations[:2]},
"theta_two_theta": {"name_zh": "理想θ–2θ展示", "meaning_zh": "engineering_assumption:样品台随2θ按一半角度显示,不模拟驱动器或惯性。", "component_ids": ["sample_holder", "goniometer"],
"state_ids": ["goniometer.two_theta_rad", "goniometer.sample_theta_rad"], "implementation": "numerical", "equations": ["sample_theta_rad=0.5*two_theta_rad"],
"parameters": {"sample_theta_ratio": params["sample_theta_ratio"], "motor_speed_rad_s": params["motor_speed_rad_s"]}, "source_ids": ["runtime_code"], "limitations": ["不宣称厂家实际传动、角度精度或动力学。"]}}
return {"asset_types": {RIGAKU_MINIFLEX600_TYPE: {"catalog_id": "CHEM-160", "model": "Rigaku | MiniFlex600,外置循环水配置", "asset_version": "1.1.0", "state_slots": slots, "capabilities": caps, "parameters": params}},
"scene_snapshot_keys": scene_keys, "host_capabilities": {
"sim.host_step": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "RigakuMiniFlex600Runtime.host_step(time_s)", "effects": reset_effects + ["goniometer.two_theta_rad", "goniometer.sample_theta_rad"]},
"sim.set_cooling": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "RigakuMiniFlex600Runtime.host_set_cooling(instance_id, connection_id=..., ready=...)", "semantics_zh": "外置循环水逻辑依赖;失去ready时立即停止扫描,保留完整点。"},
"sim.load_synthetic_response": {"kind": "simulation", "visibility": "trusted_host_only", "binding": "RigakuMiniFlex600Runtime.host_load_synthetic_response(instance_id, response)", "semantics_zh": "给当前样品、管压/管流与狭缝配置绑定合成响应网格;没有任何真实样品响应默认值。"}},
"mechanisms": mechanisms, "limitations": limitations}
class RigakuMiniFlex600Runtime:
"""Trusted simulation host. Give agents scoped sessions, never this host."""
def __init__(self, *, scene_adapter=None):
self.time_s, self.scene_adapter = 0.0, scene_adapter
self._instances, self._principals, self._requests, self._logs = {}, {}, {}, {}
self._lock, self._metadata = _mf_threading.RLock(), export_rigaku_miniflex600_contract_metadata()
self.register_principal("__public_agent__", visibility="agent")
self._agent = self.session("__public_agent__")
def create_instance(self, instance_id, asset_type_id=RIGAKU_MINIFLEX600_TYPE):
with self._lock:
if not isinstance(instance_id, str) or not instance_id or instance_id in self._instances or asset_type_id != RIGAKU_MINIFLEX600_TYPE:
raise ValueError("Unique instance and declared asset type required")
inst = {"revision": 0, "power": False, "door": 0.0, "sample": None, "cooling": None, "cooling_ready": False,
"voltage": None, "current": None, "slit": None, "two_theta": 0.0, "method": None,
"response": None, "response_sample": None, "response_configuration": None}
self._reset(inst)
if self.scene_adapter:
self.scene_adapter(instance_id, self._scene(inst))
self._instances[instance_id] = inst
@staticmethod
def _reset(inst):
inst.update({"running": False, "status": "idle", "pattern": [], "started_at": None})
@staticmethod
def _stop(inst, status):
inst["running"], inst["status"] = False, status
def register_principal(self, principal_id, *, visibility, instance_ids=None):
with self._lock:
if not isinstance(principal_id, str) or not principal_id or principal_id in self._principals or visibility not in ("agent", "debug", "evaluator"):
raise ValueError("Invalid trusted principal")
if instance_ids is not None and (not isinstance(instance_ids, (list, tuple, set, frozenset)) or any(not isinstance(s, str) for s in instance_ids)):
raise ValueError("Invalid instance scope")
scope = None if instance_ids is None else frozenset(instance_ids)
if scope is not None and not scope <= self._instances.keys():
raise ValueError("Unknown instance scope")
self._principals[principal_id], self._logs[principal_id] = (visibility, scope), []
def session(self, principal_id):
if principal_id not in self._principals:
raise ValueError("Trusted registration required")
return RigakuMiniFlex600Session(self, principal_id)
def describe(self, **kwargs):
return self._agent.describe(**kwargs)
def read(self, **kwargs):
return self._agent.read(**kwargs)
def invoke(self, **kwargs):
return self._agent.invoke(**kwargs)
def write(self, **kwargs):
return self._agent.write(**kwargs)
def _values(self, inst):
method = inst["method"]
values = {"power.enabled": inst["power"], "access.door_angle_rad": inst["door"], "slot.sample.connection_id": inst["sample"],
"cooling.connection_id": inst["cooling"], "cooling.ready": inst["cooling_ready"], "xray.voltage_v": inst["voltage"], "xray.current_a": inst["current"],
"xray.power_w": None if inst["voltage"] is None else inst["voltage"] * inst["current"], "xray.active": inst["running"], "slit.configuration_id": inst["slit"],
"goniometer.two_theta_rad": inst["two_theta"], "goniometer.sample_theta_rad": inst["two_theta"] / 2,
"scan.running": inst["running"], "scan.status": inst["status"], "scan.completed_points": len(inst["pattern"]),
"scan.total_points": 0 if method is None else method["point_count"], "measurement.pattern": inst["pattern"],
"measurement.last_intensity_cps": inst["pattern"][-1]["intensity_cps"] if inst["pattern"] else None,
"measurement.synthetic": True, "truth.response": inst["response"], "truth.sample_connection_id": inst["response_sample"]}
values.update({"scan." + k: None if method is None else method[k] for k in ("start_rad", "stop_rad", "step_rad", "integration_time_s")})
return values
def _scene(self, inst):
values = self._values(inst)
return _mf_copy.deepcopy({k: values[k] for k in self._metadata["scene_snapshot_keys"]})
def scene_snapshot(self, instance_id):
with self._lock:
return self._scene(self._instances[instance_id])
def apply_scene(self, instance_id):
with self._lock:
if self.scene_adapter is None:
raise RuntimeError("No scene adapter registered")
snapshot = self.scene_snapshot(instance_id)
self.scene_adapter(instance_id, _mf_copy.deepcopy(snapshot))
return snapshot
def _commit(self, instance_id, candidate):
old = self._instances[instance_id]
if old != candidate:
if self.scene_adapter and self._scene(old) != self._scene(candidate):
self.scene_adapter(instance_id, self._scene(candidate))
candidate["revision"] = old["revision"] + 1
self._instances[instance_id] = candidate
def host_set_cooling(self, instance_id, *, connection_id, ready):
with self._lock:
if instance_id not in self._instances or (connection_id is not None and (not isinstance(connection_id, str) or not 1 <= len(connection_id) <= 256)) or type(ready) is not bool or (ready and connection_id is None):
raise ValueError("Valid instance and explicit cooling connection/ready required")
candidate = _mf_copy.deepcopy(self._instances[instance_id])
candidate["cooling"], candidate["cooling_ready"] = connection_id, ready
if not ready and candidate["running"]:
self._stop(candidate, "cooling_lost")
self._commit(instance_id, candidate)
def host_load_synthetic_response(self, instance_id, response):
with self._lock:
inst = self._instances.get(instance_id)
schema = self._metadata["asset_types"][RIGAKU_MINIFLEX600_TYPE]["state_slots"]["truth.response"]["value_schema"]["anyOf"][0]
if inst is None or inst["running"] or inst["sample"] is None or any(inst[k] is None for k in ("voltage", "current", "slit")) or not _mf_matches(schema, response):
raise ValueError("Stopped configured sample and finite synthetic response grid required")
if any(a["two_theta_rad"] >= b["two_theta_rad"] for a, b in zip(response, response[1:])):
raise ValueError("Response angles must strictly increase")
candidate = _mf_copy.deepcopy(inst)
candidate["response"], candidate["response_sample"] = _mf_copy.deepcopy(response), inst["sample"]
candidate["response_configuration"] = (inst["voltage"], inst["current"], inst["slit"])
self._reset(candidate)
self._commit(instance_id, candidate)
@staticmethod
def _intensity(inst, angle):
response = inst["response"]
if not response[0]["two_theta_rad"] <= angle <= response[-1]["two_theta_rad"]:
raise ValueError("Synthetic response does not cover scan angle")
left, right = 0, len(response) - 1
while right - left > 1:
middle = (left + right) // 2
if response[middle]["two_theta_rad"] <= angle:
left = middle
else:
right = middle
a, b = response[left], response[right]
f = (angle - a["two_theta_rad"]) / (b["two_theta_rad"] - a["two_theta_rad"])
return (1 - f) * a["intensity_cps"] + f * b["intensity_cps"]
@staticmethod
def _angle(method, index):
if index == method["point_count"] - 1:
return method["stop_rad"]
return method["start_rad"] + index * method["step_rad"]
def host_step(self, time_s):
"""Advance absolute shared simulation time; a read never calls this."""
with self._lock:
if not _mf_number(time_s) or time_s < self.time_s:
raise ValueError("Finite monotonic absolute host time required")
if time_s == self.time_s:
return
candidates = _mf_copy.deepcopy(self._instances)
for inst in candidates.values():
if not inst["running"]:
continue
method = inst["method"]
while len(inst["pattern"]) < method["point_count"]:
idx = len(inst["pattern"])
end = inst["started_at"] + (idx + 1) * method["integration_time_s"]
if end > time_s:
break
start = inst["started_at"] + idx * method["integration_time_s"]
angle = self._angle(method, idx)
rate = self._intensity(inst, angle)
counts = rate * method["integration_time_s"]
if not all(_mf_number(x) for x in (end, start, rate, counts)) or end <= start:
raise ValueError("Synthetic integration exceeds finite numeric domain")
inst["pattern"].append({"two_theta_rad": angle, "intensity_cps": rate, "expected_counts": counts, "sample_time_s": end,
"integration_time_s": method["integration_time_s"], "sample_window_s": [start, end], "synthetic": True})
done = len(inst["pattern"])
inst["two_theta"] = self._angle(method, min(done, method["point_count"] - 1))
if done == method["point_count"]:
self._stop(inst, "completed")
# All process changes and the common clock commit together. An external
# callback may itself have partial effects and must be reconciled by host.
if self.scene_adapter:
for key, candidate in candidates.items():
if self._scene(candidate) != self._scene(self._instances[key]):
self.scene_adapter(key, self._scene(candidate))
for key, candidate in candidates.items():
if candidate != self._instances[key]:
candidate["revision"] = self._instances[key]["revision"] + 1
self._instances, self.time_s = candidates, float(time_s)
class RigakuMiniFlex600Session:
"""Identity-scoped API view; not an in-process Python security sandbox."""
def __init__(self, host, principal_id):
self.__host, self.__principal = host, principal_id
def _instance(self, instance_id):
_, scope = self.__host._principals[self.__principal]
return self.__host._instances.get(instance_id) if isinstance(instance_id, str) and (scope is None or instance_id in scope) else None
def _visible(self, definition):
visibility, _ = self.__host._principals[self.__principal]
return definition["visibility"] == "agent" or visibility in ("debug", "evaluator")
def _envelope(self, instance_id, request_id=None, *, status="succeeded", result=None, observations=None, error=None):
inst = self._instance(instance_id)
return {"protocol_version": "1.0.0", "instance_id": instance_id, "request_id": request_id, "operation_id": None, "status": status,
"state_revision": inst["revision"] if inst is not None else None, "clock": {"domain": "simulation", "time_s": self.__host.time_s},
"result": _mf_copy.deepcopy(result or {}), "observations": _mf_copy.deepcopy(observations or {}), "error": error}
def _error(self, instance_id, code, request_id=None, status="rejected"):
messages = {"UNKNOWN_INSTANCE": "Instance unavailable.", "UNKNOWN_CAPABILITY": "Capability unavailable.", "INVALID_ARGUMENT": "Invalid argument schema or numeric domain.",
"ACCESS_DENIED": "Access policy denies this request.", "PRECONDITION_FAILED": "Required sample, response, cooling or configuration unavailable.", "BUSY": "Scan is running.",
"REQUEST_CONFLICT": "Request identifier already used with different arguments.", "DEVICE_ERROR": "External scene synchronization failed; process was not committed.", "UNSUPPORTED": "This analysis is not implemented."}
return self._envelope(instance_id, request_id, status=status, error={"code": code, "message": messages[code], "retryable": False,
"side_effects": "unknown" if code == "DEVICE_ERROR" else "none", "progress": None})
def describe(self, *, asset_type_id=None, instance_id=None):
with self.__host._lock:
if (asset_type_id is None) == (instance_id is None) or (asset_type_id is not None and asset_type_id != RIGAKU_MINIFLEX600_TYPE):
return self._error(None, "INVALID_ARGUMENT")
if instance_id is not None and self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
_, scope = self.__host._principals[self.__principal]
if scope is not None and not scope:
return self._error(instance_id, "ACCESS_DENIED")
spec = _mf_copy.deepcopy(self.__host._metadata["asset_types"][RIGAKU_MINIFLEX600_TYPE])
visible = {k: v for k, v in spec["state_slots"].items() if self._visible(v)}
spec["state_slots"] = visible
spec["capabilities"].update(_mf_template_module().capability_metadata()) # template-backed sample queries (additive)
for cap in spec["capabilities"].values():
cap["state_effects"] = [e for e in cap["state_effects"] if e["state_id"] in visible]
cap["observes"] = [s for s in cap["observes"] if s in visible]
return {"protocol_version": "1.0.0", "asset_type_id": RIGAKU_MINIFLEX600_TYPE, "instance_id": instance_id,
"adapter": "basic40_runtime_measure.RigakuMiniFlex600Session", **spec, "limitations": _mf_copy.deepcopy(self.__host._metadata["limitations"])}
def read(self, *, instance_id, state_ids=None):
with self.__host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE")
slots = self.__host._metadata["asset_types"][RIGAKU_MINIFLEX600_TYPE]["state_slots"]
if state_ids is None:
state_ids = [s for s, d in slots.items() if self._visible(d)]
if not isinstance(state_ids, list) or any(not isinstance(s, str) for s in state_ids) or len(state_ids) != len(set(state_ids)):
return self._error(instance_id, "INVALID_ARGUMENT")
if any(s not in slots or not self._visible(slots[s]) for s in state_ids):
return self._error(instance_id, "ACCESS_DENIED")
values = self.__host._values(inst)
observations = {}
for sid in state_ids:
value = values[sid]
sample_time = self.__host.time_s
window = None
if sid == "measurement.last_intensity_cps":
sample_time = inst["pattern"][-1]["sample_time_s"] if inst["pattern"] else None
window = inst["pattern"][-1]["sample_window_s"] if inst["pattern"] else None
observations[sid] = {"value": _mf_copy.deepcopy(value), "unit": slots[sid]["unit"],
"quality": "unavailable" if value is None else "estimated" if slots[sid]["origin"] == "derived" else "valid",
"sample_time_s": sample_time, "sample_window_s": window, "synthetic": sid.startswith("measurement."),
"reason": "No explicitly configured value or completed synthetic measurement." if value is None else None}
return self._envelope(instance_id, observations=observations)
def invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self.__host
with host._lock:
inst = self._instance(instance_id)
if inst is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
if not isinstance(capability_id, str) or not isinstance(arguments, dict) or not isinstance(request_id, str) or not 1 <= len(request_id) <= 256:
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
try:
digest = _mf_hashlib.sha256(_mf_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False).encode()).hexdigest()
except (TypeError, ValueError, OverflowError):
return self._error(instance_id, "INVALID_ARGUMENT", request_id)
key = self.__principal, instance_id, request_id
if key in host._requests:
old_digest, result = host._requests[key]
return _mf_copy.deepcopy(result) if old_digest == digest else self._error(instance_id, "REQUEST_CONFLICT", request_id)
response = self._checked(instance_id, inst, capability_id, arguments, request_id)
host._requests[key] = digest, _mf_copy.deepcopy(response)
host._logs[self.__principal].append({"instance_id": instance_id, "capability_id": capability_id, "request_id": request_id, "response": _mf_copy.deepcopy(response)})
return response
def _checked(self, instance_id, inst, cap, args, request_id):
host = self.__host
fail = lambda code, status="rejected": self._error(instance_id, code, request_id, status)
if cap in ("template.read", "xrd.read_template_pattern"): # additive template-backed queries (read-only)
return _mf_template_module().session_query(self, host, instance_id, inst, cap, args, request_id)
caps = host._metadata["asset_types"][RIGAKU_MINIFLEX600_TYPE]["capabilities"]
if cap not in caps:
return fail("UNKNOWN_CAPABILITY")
if not _mf_matches(caps[cap]["input_schema"], args):
return fail("INVALID_ARGUMENT")
if caps[cap]["availability"] == "unsupported":
return fail("UNSUPPORTED", "unsupported")
if inst["running"] and cap not in ("power.set", "xrd.stop_scan", "xrd.read_pattern"):
return fail("BUSY")
if cap == "slot.set_sample" and inst["door"] <= 0:
return fail("PRECONDITION_FAILED")
if cap == "xray.configure" and (not _mf_grid(args["voltage_v"], 1000) or not _mf_grid(args["current_a"], 0.001) or args["voltage_v"] * args["current_a"] > 600):
return fail("INVALID_ARGUMENT")
if cap == "motion.set_two_theta":
if not _mf_grid(args["angle_rad"], RIGAKU_MINIFLEX600_STEP_RAD):
return fail("INVALID_ARGUMENT")
if not inst["power"] or inst["door"] != 0:
return fail("PRECONDITION_FAILED")
if cap == "xrd.configure_scan":
if args["start_rad"] > args["stop_rad"] or not all(_mf_grid(args[k], RIGAKU_MINIFLEX600_STEP_RAD) for k in ("start_rad", "stop_rad", "step_rad")):
return fail("INVALID_ARGUMENT")
intervals = (args["stop_rad"] - args["start_rad"]) / args["step_rad"]
if not _mf_number(intervals) or abs(intervals - round(intervals)) > 1e-7 or round(intervals) + 1 > RIGAKU_MINIFLEX600_MAX_POINTS:
return fail("INVALID_ARGUMENT")
count = round(intervals) + 1
duration = count * args["integration_time_s"]
if not _mf_number(duration) or duration <= 0:
return fail("INVALID_ARGUMENT")
if cap == "xrd.start_scan":
if not inst["power"] or inst["door"] != 0 or not inst["cooling_ready"] or inst["cooling"] is None or inst["sample"] is None or inst["sample"] != inst["response_sample"] or inst["response"] is None or inst["method"] is None or any(inst[k] is None for k in ("voltage", "current", "slit")):
return fail("PRECONDITION_FAILED")
if inst["response_configuration"] != (inst["voltage"], inst["current"], inst["slit"]):
return fail("PRECONDITION_FAILED")
method, response = inst["method"], inst["response"]
if response[0]["two_theta_rad"] > method["start_rad"] or response[-1]["two_theta_rad"] < method["stop_rad"]:
return fail("PRECONDITION_FAILED")
first_end = host.time_s + method["integration_time_s"]
last_end = host.time_s + method["point_count"] * method["integration_time_s"]
max_counts = max(p["intensity_cps"] for p in response) * method["integration_time_s"]
if not all(_mf_number(v) for v in (first_end, last_end, max_counts)) or first_end <= host.time_s or (method["point_count"] > 1 and last_end <= first_end):
return fail("INVALID_ARGUMENT")
if cap == "xrd.read_pattern":
return self._envelope(instance_id, request_id, result={"samples": inst["pattern"], "status": inst["status"], "synthetic": True})
candidate, result = _mf_copy.deepcopy(inst), dict(args)
if cap == "power.set":
candidate["power"] = args["enabled"]
if not args["enabled"] and candidate["running"]:
host._stop(candidate, "power_lost")
elif cap == "access.set_door_angle":
candidate["door"] = args["angle_rad"]
elif cap == "slot.set_sample":
if candidate["sample"] != args["connection_id"]:
candidate["sample"] = args["connection_id"]
candidate["response"], candidate["response_sample"], candidate["response_configuration"] = None, None, None
host._reset(candidate)
elif cap == "xray.configure":
candidate["voltage"], candidate["current"] = args["voltage_v"], args["current_a"]
elif cap == "xrd.configure_scan":
candidate["method"] = {**args, "point_count": count}
host._reset(candidate)
elif cap == "xrd.set_slit":
candidate["slit"] = args["slit_id"]
elif cap == "motion.set_two_theta":
candidate["two_theta"] = args["angle_rad"]
elif cap == "xrd.start_scan":
host._reset(candidate)
candidate["started_at"], candidate["running"], candidate["status"] = host.time_s, True, "running"
candidate["two_theta"] = candidate["method"]["start_rad"]
result = {"status": "running", "synthetic": True}
elif cap == "xrd.stop_scan":
if candidate["running"]:
host._stop(candidate, "stopped")
result = {"status": candidate["status"], "synthetic": True}
try:
host._commit(instance_id, candidate)
except Exception:
return fail("DEVICE_ERROR", "failed")
return self._envelope(instance_id, request_id, result=result)
def write(self, *, instance_id, state_id, value, request_id):
with self.__host._lock:
if self._instance(instance_id) is None:
return self._error(instance_id, "UNKNOWN_INSTANCE", request_id)
slots = self.__host._metadata["asset_types"][RIGAKU_MINIFLEX600_TYPE]["state_slots"]
if not isinstance(state_id, str) or state_id not in slots or not self._visible(slots[state_id]) or slots[state_id]["write_via"] is None:
return self._error(instance_id, "ACCESS_DENIED", request_id)
route = slots[state_id]["write_via"]
return self.invoke(instance_id=instance_id, capability_id=route["capability_id"], arguments={**route["fixed_arguments"], route["parameter"]: value}, request_id=request_id)
def logs(self):
with self.__host._lock:
return _mf_copy.deepcopy(self.__host._logs[self.__principal])
def write_rigaku_miniflex600_runtime_reports(output_directory):
import datetime
import importlib.util
import io
import pathlib
import platform
import unittest
root = pathlib.Path(__file__).resolve().parents[1]
spec = importlib.util.spec_from_file_location("test_basic40_measure_rigaku_miniflex600", root / "tests/test_basic40_measure.py")
module = importlib.util.module_from_spec(spec)
spec.loader.exec_module(module)
stream = io.StringIO()
result = unittest.TextTestRunner(stream=stream, verbosity=2).run(unittest.defaultTestLoader.loadTestsFromTestCase(module.RigakuMiniFlex600RuntimeTests))
metadata = export_rigaku_miniflex600_contract_metadata()
caps = metadata["asset_types"][RIGAKU_MINIFLEX600_TYPE]["capabilities"]
report = {"catalog_id": "CHEM-160", "checked_at": datetime.datetime.now(datetime.timezone.utc).isoformat(),
"environment": {"python": platform.python_version(), "platform": platform.platform(), "runtime": "standard-library Python; synthetic fixtures only; no Blender"},
"method": "unittest: uniform entrypoints, SI limits/quantization, door/sample/cooling/tube interlocks, deterministic explicit-host scans, count integration, partial stops, monotonic shared time, rejection atomicity, instance/session isolation, in-memory idempotency, schemas and declared effects, scene callback boundaries",
"tests_run": result.testsRun, "failures": len(result.failures), "errors": len(result.errors), "result": "passed" if result.wasSuccessful() else "failed",
"passed_capabilities": sorted(k for k, v in caps.items() if v["availability"] == "implemented") if result.wasSuccessful() else [],
"verified_unsupported": ["xrd.phase_search", "xrd.refine"] if result.wasSuccessful() else [],
"output": stream.getvalue(), "synthetic": True,
"not_run": ["real_hardware", "robot_execution", "contact_solver", "Blender_evaluated_pose", "process_filesystem_security_isolation", "real_diffraction_accuracy", "phase_identification", "rietveld_refinement", "instrument_broadening", "preferred_orientation", "poisson_count_noise", "radiation_shielding", "coolant_thermal_hydraulics"],
"scene_scope": "Only recording/failing callbacks and scene snapshot mapping are tested here; the parent owns evaluated Blender validation separately.",
"boundaries": metadata["limitations"]}
directory = pathlib.Path(output_directory)
directory.mkdir(parents=True, exist_ok=True)
for name, value in (("runtime_validation.json", report), ("runtime_metadata.json", metadata)):
(directory / name).write_text(_mf_json.dumps(value, ensure_ascii=False, indent=2) + "\n", encoding="utf-8")
return report
# CHEM-160 template-backed powder samples (RRUFF/COD XRD library, scripts/basic40_templates/rigaku_miniflex600.py); host-only, additive.
def _mf_template_module():
"""Lazy import of the public-data XRD template extension."""
try:
from .basic40_templates import rigaku_miniflex600 as module
except ImportError:
from basic40_templates import rigaku_miniflex600 as module
return module
def _mf_host_load_template_sample(self, instance_id, phases):
return _mf_template_module().load_template_sample(self, instance_id, phases)
def _mf_template_sample_truth(self, instance_id):
return _mf_template_module().template_sample_truth(self, instance_id)
RigakuMiniFlex600Runtime.host_load_template_sample = _mf_host_load_template_sample
RigakuMiniFlex600Runtime.template_sample_truth = _mf_template_sample_truth
# END CHEM-160 RIGAKU MINIFLEX600 APPEND-ONLY RUNTIME
# CHEM-102 independent review: append-only fixes for failed-request replay and
# representable host time; no prior asset classes or blocks are modified.
_kf899_review_original_invoke = Metrohm899Session.invoke
def _kf899_reviewed_invoke(self, *, instance_id, capability_id, arguments, request_id):
host = self._kf899_host
with host._kf899_lock:
response = _kf899_review_original_invoke(self, instance_id=instance_id,
capability_id=capability_id, arguments=arguments, request_id=request_id)
if self._kf899_allowed(instance_id) and isinstance(request_id, str) and request_id and isinstance(capability_id, str) and isinstance(arguments, dict):
try:
fingerprint = _kf899_json.dumps([capability_id, arguments], sort_keys=True, allow_nan=False)
except (ValueError, TypeError, OverflowError):
return response
key = (self._kf899_principal, instance_id, request_id)
if key not in host._kf899_requests:
# In particular cache DEVICE_ERROR/unknown outcomes: repeating
# a logical request must not replay external scene side effects.
host._kf899_requests[key] = (fingerprint, _kf899_copy.deepcopy(response))
return response
Metrohm899Session.invoke = _kf899_reviewed_invoke
def _kf899_reviewed_step(self, dt_s):
"""Common-clock step with precommit finite/representable-time validation.
Process states and time commit together after all callbacks return. The
callbacks are per-instance, not a transaction across scene instances: an
exception may leave earlier external scene callbacks applied. The trusted
host must reconcile all affected scene instances after any callback error.
"""
with self._kf899_lock:
if not _kf899_number(dt_s) or dt_s < 0 or not _kf899_number(self.time_s + dt_s):
raise ValueError("Finite nonnegative time increment required")
if dt_s == 0:
return {"time_s": self.time_s, "synthetic": True}
end_time = self.time_s + float(dt_s)
if end_time <= self.time_s:
raise ValueError("Positive increment is not representable at current host time")
candidates = _kf899_copy.deepcopy(self._kf899_instances)
for iid, instance in candidates.items():
s = instance["state"]
if not s["coulometry.running"]:
continue
pre_elapsed = s["measurement.elapsed_s"]
checks = (pre_elapsed + dt_s, s["settings.current_a"] * dt_s,
s["truth.water_remaining_kg"] + s["truth.background_drift_kg_s"] * dt_s,
s["settings.drift_compensation_kg_s"] * (pre_elapsed + dt_s))
if not all(_kf899_number(v) for v in checks):
raise ValueError("Requested integration exceeds finite numerical range")
remaining_dt, advanced = float(dt_s), 0.0
drift = s["truth.background_drift_kg_s"]
rate = s["settings.current_a"] * KF899_KG_PER_COULOMB
extract_remaining = max(0.0, s["settings.extraction_time_s"] - pre_elapsed)
extract = min(remaining_dt, extract_remaining)
s["truth.water_remaining_kg"] += drift * extract
remaining_dt -= extract
advanced += extract
s["coulometry.status"] = "EXTRACTING" if remaining_dt == 0 and extract_remaining > extract else "TITRATING"
if remaining_dt > 0:
water, net_rate = s["truth.water_remaining_kg"], rate - drift
depletion_time = water / net_rate if net_rate > 0 else float("inf")
drive = min(remaining_dt, depletion_time)
s["measurement.charge_c"] += s["settings.current_a"] * drive
s["truth.water_remaining_kg"] = max(0.0, water - net_rate * drive)
remaining_dt -= drive
advanced += drive
if depletion_time <= drive:
s["truth.water_remaining_kg"] = 0.0
s["coulometry.status"] = "HOLDING"
hold_remaining = max(0.0, s["settings.endpoint_hold_s"] - s["endpoint.hold_elapsed_s"])
hold = min(remaining_dt, hold_remaining)
s["measurement.charge_c"] += drift * hold / KF899_KG_PER_COULOMB
s["endpoint.hold_elapsed_s"] += hold
advanced += hold
if s["endpoint.hold_elapsed_s"] >= s["settings.endpoint_hold_s"]:
s["coulometry.running"] = False
s["coulometry.status"] = "COMPLETED"
s["measurement.elapsed_s"] = pre_elapsed + advanced
s["measurement.sample_time_s"] = self.time_s + advanced
if advanced > 0 and (s["measurement.elapsed_s"] <= pre_elapsed or s["measurement.sample_time_s"] <= self.time_s):
raise ValueError("Acquisition interval is not representable at current host time")
generated = s["measurement.charge_c"] * KF899_KG_PER_COULOMB
compensation = s["settings.drift_compensation_kg_s"] * s["measurement.elapsed_s"]
if not _kf899_number(generated) or not _kf899_number(compensation):
raise ValueError("Integration exceeds finite numerical range")
s["measurement.water_mass_kg"] = max(0.0, generated - compensation)
mass = s["settings.sample_mass_kg"]
s["measurement.water_fraction"] = None if mass is None else s["measurement.water_mass_kg"] / mass
if any(type(value) in (int, float) and not _kf899_number(value) for value in s.values()):
raise ValueError("Integration exceeds finite numerical range")
instance["revision"] += 1
instance["curve"].append({**_kf899_reading(s), "sample_time_s": s["measurement.sample_time_s"]})
# No callback runs before all instances pass numerical validation.
for iid, instance in candidates.items():
if instance != self._kf899_instances[iid]:
self._kf899_sync(iid, instance["state"])
self._kf899_instances = candidates
self.time_s = end_time
return {"time_s": self.time_s, "synthetic": True}
Metrohm899Host.step = _kf899_reviewed_step
_kf899_review_original_metadata = export_metrohm899_contract_metadata
def export_metrohm899_contract_metadata():
result = _kf899_review_original_metadata()
result["boundaries"].extend([
"Failed scene callback outcomes are cached by logical request ID; retry does not replay the callback. A new request after reconciliation is explicit host/operator action.",
"Host step commits process/time together, but callbacks across scene instances are not transactional. A later callback failure can leave earlier scene instances changed; host must reconcile every affected scene instance.",
"Positive host increments and nonzero acquisition intervals that cannot be represented at the current floating-point time are rejected before callbacks or process mutation.",
"Slot installation/removal is a powered-off, idle scene configuration with cell-before-electrode dependencies. It does not simulate handling force, reagent spills, physical transfers or sample-container identity changes."])
return result
# CHEM-102 reproducible dedicated report writer; no other asset outputs touched.
def write_metrohm899_runtime_reports(output_directory):
import datetime
import importlib.util
import io
import pathlib
import platform
import subprocess
import unittest
root = pathlib.Path(__file__).resolve().parents[1]
spec = importlib.util.spec_from_file_location("test_basic40_measure_metrohm899", root / "tests/test_basic40_measure.py")
module = importlib.util.module_from_spec(spec)
spec.loader.exec_module(module)
stream = io.StringIO()
suite = unittest.defaultTestLoader.loadTestsFromTestCase(module.Metrohm899RuntimeTests)
result = unittest.TextTestRunner(stream=stream, verbosity=2).run(suite)
meta = export_metrohm899_contract_metadata()
report = {"catalog_id": "CHEM-102", "asset_type_id": METROHM899_TYPE,
"recorded_at": datetime.datetime.now(datetime.timezone.utc).isoformat(),
"shell_utc_at_recording": subprocess.check_output(["date", "-u", "+%Y-%m-%dT%H:%M:%SZ"], text=True).strip(),
"environment": {"python": platform.python_version(), "platform": platform.platform()},
"method": "unittest Metrohm899RuntimeTests: SI I/Q/m conservation, analytic extraction/depletion/hold with drift compensation and step partitioning; every API output schema and state effect; slots and null drift; retained stop/power effects; two active instances and common representable clock; request idempotency including callback failures; truth/curve/copy filtering; process rollback and explicitly partial external scene callback failure",
"command": "PYTHONDONTWRITEBYTECODE=1 PYTHONPATH=scripts:tests python3 -m unittest test_basic40_measure.Metrohm899RuntimeTests -v",
"report_writer": "scripts.basic40_runtime_measure.write_metrohm899_runtime_reports(output_directory)",
"tests_run": result.testsRun, "failures": len(result.failures), "errors": len(result.errors),
"result": "passed" if result.wasSuccessful() else "failed", "synthetic": True,
"verified_layers": ["process", "host"] if result.wasSuccessful() else [],
"capabilities_verified": sorted(meta["capabilities"]) if result.wasSuccessful() else [],
"scene_scope": "Recording/failing callback tests only; evaluated Blender pose requires a separate geometry verification record. Cross-instance callbacks are not an external scene transaction.",
"not_run": ["real_hardware", "robot_execution", "contact_solver", "real_reagent_or_electrode_kinetics", "manufacturer_accuracy_or_noise", "automatic_current_firmware", "process_filesystem_sandbox", "evaluated_blender_pose_in_runtime_tests"],
"boundaries": meta["boundaries"], "output": stream.getvalue()}
directory = pathlib.Path(output_directory)
directory.mkdir(parents=True, exist_ok=True)
for name, value in (("runtime_validation.json", report), ("runtime_manifest.json", meta)):
(directory / name).write_text(_kf899_json.dumps(value, ensure_ascii=False, indent=2) + "\n", encoding="utf-8")
(directory / "runtime_test_report.txt").write_text(stream.getvalue(), encoding="utf-8")
return report
|