■ If you earlier had configured speed 100 on an interface, the no speed command on that same interface reverts to the default speed setting (which happens to be speed auto). |
■ Same idea with the duplex command: an earlier configuration of duplex half or duplex full, followed by no duplex on the same interface, reverts the configuration back to the default of duplex auto. |
■ If you had configured a description command with some text, to go back to the default state of having no description command at all for that interface, use the no description command. |
Example 7-6 shows the process. In this case, switch SW1’s F0/2 port has been configured with speed 100, duplex half, description link to 2901-2, and shutdown. You can see |
evidence of all four settings in the command that begins the example. (This command lists |
the running-config, but only the part for that one interface.) The example then shows the 7 |
no versions of those commands and closes with a confirmation that all the commands have reverted to default. |
Example 7-6 Removing Various Configuration Settings Using the no Command |
SW1# show running-config interface f0/2 |
Building configuration... |
Current configuration : 95 bytes |
! |
interface FastEthernet0/2 |
description link to 2901-2 |
shutdown |
speed 100 |
duplex half |
end |
SW1# configure terminal |
Enter configuration commands, one per line. End with CNTL/Z. |
SW1(config)# interface fastethernet 0/2 |
SW1(config-if)# no speed |
SW1(config-if)# no duplex |
SW1(config-if)# no description |
SW1(config-if)# no shutdown |
|||||||||||||||||||| |
|||||||||||||||||||| |
158 CCNA 200-301 Official Cert Guide, Volume 1 |
SW1(config-if)# ^Z |
SW1# |
SW1# show running-config interface f0/2 |
Building configuration... |
Current configuration : 33 bytes |
! |
interface FastEthernet0/2 |
end |
SW1# |
NOTE The show running-config and show startup-config commands typically do not dis-play default configuration settings, so the absence of commands listed under interface F0/2 at the end of the example means that those commands now use default values. |
Autonegotiation |
For any 10/100 or 10/100/1000 interfaces—that is, interfaces that can run at different speeds—Cisco Catalyst switches default to a setting of duplex auto and speed auto. As a result, those interfaces attempt to automatically determine the speed and duplex setting to use. Alternatively, you can configure most devices, s... |
In practice, using autonegotiation is easy: just leave the speed and duplex at the default set-ting, and let the switch port negotiate what settings to use on each port. However, problems can occur due to unfortunate combinations of configuration. Therefore, this next topic walks through more detail about the concepts ... |
Autonegotiation Under Working Conditions |
Ethernet devices on the ends of a link must use the same standard; otherwise, they can-not correctly send data. For example, a NIC cannot use 100BASE-T, which uses a two-pair UTP cable with a 100-Mbps speed, while the switch port on the other end of the link uses |
1000BASE-T. Even if you used a cable that works with Gigabit Ethernet, the link would not work with one end trying to send at 100 Mbps while the other tried to receive the data at 1000 Mbps. |
Upgrading to new and faster Ethernet standards becomes a problem because both ends have to use the same standard. For example, if you replace an old PC with a new one, the old one might have been using 100BASE-T while the new one uses 1000BASE-T. The switch port on the other end of the link needs to now use 1000BASE-T,... |
|||||||||||||||||||| Technet24 |
|||||||||||||||||||| |
Chapter 7: Configuring and Verifying Switch Interfaces 159 |
The IEEE autonegotiation protocol helps makes it much easier to operate a LAN when NICs and switch ports support multiple speeds. IEEE autonegotiation (IEEE standard 802.3u) defines a protocol that lets the two UTP-based Ethernet nodes on a link negotiate so that they each choose to use the same speed and duplex settin... |
NOTE Autonegotiation relies on the fact that the IEEE uses the same wiring pinouts for 10BASE-T and 100BASE-T, and that 1000BASE-T simply adds to those pinouts, adding two pairs. |
Many networks use autonegotiation every day, particularly between user devices and the access layer LAN switches, as shown in Figure 7-1. The company installed four-pair cabling of the right quality to support 1000BASE-T, to be ready to support Gigabit Ethernet. As a result, the wiring supports 10-Mbps, 100-Mbps, and 1... |
Autonegotiation Enabled |
10 10/100 10/100/1000 7 |
1 |
Result: 10 Full |
10/100/1000 |
2 |
Result: 100 Full |