PureOne's picture
Publish Neixarua release 3: manuscript, proofs, claim corpus and reproducibility
ee3d849 verified
Raw History Blame Contribute Delete
14 kB
\chapter{Reversal defects of observation protocols}
\label{chap:protocols}\label{ch:protocols}
\section{Physical reversal and reversal of a recorded string}
Let $X,Y$ be standard Borel spaces with measurable involutions $R:X\to X$ and $r:Y\to Y$. The input can be a complete microscopic history and the output a complete measurement record. For a Markov observation kernel $K:X\rightsquigarrow Y$, define
\begin{equation}
K^R(x,B)=K(Rx,r^{-1}B).
\label{eq:reverse-kernel}
\end{equation}
This conjugation includes reversal of both the physical input and the record convention. For a source law $P$ and $Q=R_*P$,
\begin{equation}
r_*(PK)=QK^R.
\label{eq:tape-vs-source}
\end{equation}
Consequently the same-detector source comparison $(PK,QK)$ differs in general from comparing a recording to its reversed recording $(PK,r_*PK)$. They coincide for every source law exactly when $K=K^R$. Whether a laboratory backward protocol realizes $K^R$ is an operational calibration question.
The distinction also applies to order reversal of trajectories. Momentum, magnetic fields, control waveforms, preparation of memory and stopping rules can transform under physical reversal. A map that merely reverses a list of timestamps need not implement that transformation. The following results make this issue algebraically testable.
\section{A composable even--odd decomposition}
Write
\begin{equation}
s=\frac{P+R_*P}{2},\qquad d=\frac{P-R_*P}{2},\qquad
K_+=\frac{K+K^R}{2},\qquad K_-=\frac{K-K^R}{2}.
\label{eq:parity-decomposition}
\end{equation}
Here $s$ is a symmetric probability, $d$ is an antisymmetric signed measure, and $d=a s$ with $|a|\leq1$. The kernel $K_+$ is Markov; $K_-$ is a signed kernel of total mass zero. Its pointwise variation satisfies $|K_-(x,\cdot)|\leq K_+(x,\cdot)$. Conversely $K_+\pm K_-\geq0$, normalization and the appropriate parity identities characterize admissible pairs.
\begin{theorem}[Protocol transport and composition]
\label{thm:parity-transport}
Set $P'=PK$, $s'=(P'+r_*P')/2$ and $d'=(P'-r_*P')/2$. Then
\begin{align}
s'&=sK_+ + dK_-,&
d'&=dK_+ + sK_-.
\label{eq:parity-transport}
\end{align}
For a subsequent observation kernel $L:Y\rightsquigarrow Z$ with a specified output involution,
\begin{align}
(KL)_+&=K_+L_++K_-L_-,\\
(KL)_-&=K_+L_-+K_-L_+.
\label{eq:parity-composition}
\end{align}
Composition is associative and preserves the cone $s\pm d\geq0$. With $\|\cdot\|_{\rm var}$ denoting full signed-measure variation,
\begin{align}
\big|\|dK_+\|_{\rm var}-\|sK_-\|_{\rm var}\big|
&\leq\|d'\|_{\rm var}
\leq\|dK_+\|_{\rm var}+\|sK_-\|_{\rm var},\\
\|dK_+\|_{\rm var}&\leq\|d\|_{\rm var},\\
\|sK_-\|_{\rm var}
&\leq\int\operatorname{TV}(K(x,\cdot),K^R(x,\cdot))\,s(dx).
\label{eq:protocol-bounds}
\end{align}
Since $d=(P-R_*P)/2$, $\|d\|_{\rm var}=\operatorname{TV}(P,R_*P)$.
\end{theorem}
\begin{proof}
Substitute $P=s+d$, $Q=s-d$, $K=K_++K_-$ and $K^R=K_+-K_-$ into $(PK\pm QK^R)/2$, using \eqref{eq:tape-vs-source}. This gives \eqref{eq:parity-transport}. In the composition integral, the substitution $y\mapsto r(y)$ proves $(KL)^R=K^RL^R$. Adding and subtracting the two expanded products gives \eqref{eq:parity-composition}. Associativity is ordinary kernel associativity. Positivity follows from
\[
s'+d'=(s+d)(K_++K_-)=PK,\qquad
s'-d'=(s-d)(K_+-K_-)=QK^R.
\]
The reverse and ordinary triangle inequalities give the first estimate. Variation contracts under the Markov kernel $K_+$, proving the second. Finally
\[
\|sK_-\|_{\rm var}\leq\int\|K_-(x,\cdot)\|_{\rm var}s(dx),
\]
and $\|K_-(x,\cdot)\|_{\rm var}=\operatorname{TV}(K(x,\cdot),K^R(x,\cdot))$.
\end{proof}
The theorem separates source oddness $dK_+$ and protocol oddness $sK_-$ as signed measures. It also shows that the symmetric reference measure changes through the coupling term $dK_-$. Treating that reference as fixed would generally give an incorrect normalized score. The algebra is the ordinary $\mathbb Z_2$ grading of kernels; the substantive use is its operational interpretation, composition across observation scales, and integration with the clock and branching constraints.
\section{An exact bounded source--protocol score law}
Because $|K_-|\leq K_+$, standard Borel Radon--Nikodym versions supply a jointly measurable function $\kappa$ satisfying
\begin{equation}
K_-(x,dy)=\kappa(x,y)K_+(x,dy),\qquad |\kappa|\leq1.
\end{equation}
For each input, $\int\kappa(x,y)K_+(x,dy)=0$. Define the reference joint law
\begin{equation}
\mu(dx,dy)=s(dx)K_+(x,dy).
\end{equation}
This is a reference for the algebraic decomposition, not the actual mixture of the two joint experiments unless the coupling term vanishes.
\begin{theorem}[Exact posterior transport with a reversal defect]
\label{thm:protocol-score}
The actual joint forward and reversed laws
\[
J_+(dx,dy)=P(dx)K(x,dy),\qquad
J_-(dx,dy)=Q(dx)K^R(x,dy)
\]
have densities relative to $\mu$
\begin{equation}
\frac{dJ_+}{d\mu}=(1+a)(1+\kappa),\qquad
\frac{dJ_-}{d\mu}=(1-a)(1-\kappa).
\label{eq:protocol-joint-densities}
\end{equation}
Their actual mixture is $(1+a\kappa)\mu$. Its orientation score is
\begin{equation}
a_{XY}=\frac{a+\kappa}{1+a\kappa}.
\label{eq:protocol-joint-score}
\end{equation}
After the source variable is hidden, the record score is exactly
\begin{equation}
a_Y(y)=
\frac{\mathbb E_\mu[a+\kappa\mid Y=y]}
{1+\mathbb E_\mu[a\kappa\mid Y=y]}.
\label{eq:protocol-output-score}
\end{equation}
Each ratio is used where its denominator is positive. A zero denominator forces a zero numerator and lies in a null set of the corresponding actual mixture. Hence the theorem includes singular experiments without an undefined infinity-minus-infinity expression.
\end{theorem}
\begin{proof}
Use $P=(1+a)s$, $Q=(1-a)s$, $K=(1+\kappa)K_+$ and $K^R=(1-\kappa)K_+$ to obtain \eqref{eq:protocol-joint-densities}. Half their sum is $1+a\kappa$ and half their difference is $a+\kappa$, proving \eqref{eq:protocol-joint-score}. Integrating the two densities conditionally against the $Y$ marginal of $\mu$ gives \eqref{eq:protocol-output-score}. Nonnegativity of both joint densities implies $|a+\kappa|\leq1+a\kappa$. The same inequality survives conditional expectation, proving the assertion at zero denominators.
\end{proof}
If $|a|,|\kappa|<1$ and no source variable is hidden, the joint formula gives the familiar log-odds addition
\[
\operatorname{artanh}a_{XY}
=\operatorname{artanh}a+\operatorname{artanh}\kappa.
\]
The ratio formula is preferable because it also treats singular endpoints and observation-induced cancellation. Averaging the separate log odds does not in general produce the observable log odds.
\section{Information accounting without false scalar attribution}
\begin{theorem}[Exact joint-to-record information budget]
\label{thm:protocol-js-budget}
Under the equal-prior label $T$ with conditional joint laws $J_+,J_-$ above,
\begin{equation}
\operatorname{JS}(PK,QK^R)
=\operatorname{JS}(P,Q)+I(T;Y\mid X)-I(T;X\mid Y).
\label{eq:protocol-js-budget}
\end{equation}
Every term is finite. The conditional protocol contribution $I(T;Y\mid X)$ uses the posterior label probabilities given $X$; it is not generally an average of equal-prior conditional JS divergences.
For KL divergence the correct extended statement is
\begin{align}
D(J_+\Vert J_-)
&=D(P\Vert Q)+\int D(K(x,\cdot)\Vert K^R(x,\cdot))\,P(dx)\\
&=D(PK\Vert QK^R)
+\int D(J_+(dx\mid y)\Vert J_-(dx\mid y))\,PK(dy).
\label{eq:protocol-kl-budget}
\end{align}
The two equalities involve only sums of nonnegative extended values. Subtraction is justified only when the joint divergence is finite.
\end{theorem}
\begin{proof}
Expand the same mutual information in the two orders:
\[
I(T;X,Y)=I(T;X)+I(T;Y\mid X)
=I(T;Y)+I(T;X\mid Y).
\]
The marginal pairs identify $I(T;X)$ and $I(T;Y)$ with the two JS terms. Since $T$ is one binary label, all terms are bounded by $\log2$, so rearrangement is valid. The two KL equalities follow by applying Proposition~\ref{prop:kl-chain} to the same joint pair in its two marginal orders.
\end{proof}
This identity supplies an exact separation at the level of a fully specified experiment. It does not permit one to infer source preparation or detector calibration solely from output data. Those quantities can be nonidentifiable.
\begin{example}[Exact cancellation between source and apparatus]
\label{ex:protocol-cancellation}
Let $X=Y=\{+,-\}$ with sign-exchange involutions. Take
\[
P=(0.8,0.2),\qquad Q=(0.2,0.8),\qquad
K=\begin{pmatrix}0.6&0.4\\0.1&0.9\end{pmatrix}.
\]
Then
\[
K^R=\begin{pmatrix}0.9&0.1\\0.4&0.6\end{pmatrix},\quad
K_+=\begin{pmatrix}0.75&0.25\\0.25&0.75\end{pmatrix},\quad
K_-=\begin{pmatrix}-0.15&0.15\\-0.15&0.15\end{pmatrix}.
\]
The input components are $s=(0.5,0.5)$ and $d=(0.3,-0.3)$. Thus
\[
dK_+=(0.15,-0.15),\qquad sK_-=(-0.15,0.15),
\]
so $d'=0$. Both signed contributions have variation $0.3$, but the actual output is uniform and has no record-reversal arrow. The source arrow has total variation $0.6$. Therefore a universal formula of the form ``nonnegative source arrow plus nonnegative apparatus arrow'' cannot represent the observed arrow.
\end{example}
\begin{proposition}[Output-only attribution is impossible]
\label{prop:attribution-impossibility}
No functional of $(PK,r_*PK)$ alone can universally determine whether its asymmetry originated in the source or in the protocol.
\end{proposition}
\begin{proof}
Fix any nonsymmetric output law $H$ on $(Y,r)$. One realization uses $X=Y$, $P=H$, $R=r$ and the identity channel, which is equivariant. All asymmetry is then source asymmetry. A second realization uses a one-point input with its symmetric law and a constant kernel that emits $H$. All asymmetry is then protocol asymmetry. Both realizations have exactly the output pair $(H,r_*H)$, proving the claim.
\end{proof}
\section{No false positives, calibration, and faithful detection}
It is useful to separate three operational requirements: a detector may avoid generating an arrow from symmetric input; it may correctly commute with reversal on every input; or it may reveal every asymmetric input. These requirements are different.
\begin{theorem}[Exact universal neutrality and calibration criteria]
\label{thm:protocol-neutrality}
For a kernel $K:X\rightsquigarrow Y$ the following are equivalent:
\begin{enumerate}
\item $PK$ is $r$-invariant for every $R$-invariant probability $P$;
\item $K(x,\cdot)+K(Rx,\cdot)$ is $r$-invariant for every $x$;
\item $sK_-=0$ for every $R$-invariant probability $s$.
\end{enumerate}
The stronger calibration condition
\begin{equation}
r_*(PK)=(R_*P)K\quad\hbox{for every probability }P
\label{eq:universal-calibration}
\end{equation}
holds if and only if $K=K^R$. Calibration implies neutrality; its converse is false.
\end{theorem}
\begin{proof}
For necessity of the second condition, apply the first to the symmetric orbit law $(\delta_x+\delta_{Rx})/2$. Conversely, integrate the second condition against an invariant $P$; the two summands give the same output law, so that law is invariant. For invariant $s$, the odd output part in \eqref{eq:parity-transport} is $sK_-$, proving equivalence with the third condition. Testing \eqref{eq:universal-calibration} on $P=\delta_x$ gives $r_*K(x,\cdot)=K(Rx,\cdot)$, exactly $K=K^R$. Integrating that equality proves sufficiency. The counterexample below separates calibration from neutrality.
\end{proof}
\begin{example}[Neutral but not calibrated]
Let $X=\{+,-\}$ with exchange, $Y=\{-1,0,1\}$ with $r(y)=-y$, and
\[
K(+)=\delta_0,\qquad K(-)=\tfrac12(\delta_{-1}+\delta_1).
\]
Every output law is $r$-invariant, so the detector is neutral. But $K(+)$ is not $r_*K(-)$, so it is not calibrated. It also hides every source arrow. By contrast a constant detector that always prints $+1$ from a symmetric source produces a maximal apparatus arrow, with no source information at all.
\end{example}
\begin{proposition}[Faithfulness on the antisymmetric sector]
\label{prop:odd-faithfulness}
Assume universal neutrality. Then $PK$ is symmetric if and only if $P$ is symmetric, for every input probability $P$, exactly when the map
\begin{equation}
d\longmapsto dK_+
\end{equation}
is injective on finite signed measures satisfying $R_*d=-d$. Such measures automatically have total mass zero.
\end{proposition}
\begin{proof}
Neutrality gives $sK_-=0$, so the odd output measure is $dK_+$. Injectivity therefore implies the stated equivalence. For necessity let a nonzero antisymmetric signed measure $d$ satisfy $dK_+=0$. Its Jordan parts are exchanged by $R$ and have equal positive mass $m$. Set $P=d^+/m$, so $R_*P=d^-/m$ and $(P-R_*P)/2=d/(2m)$. This nonsymmetric probability has symmetric output, contradicting faithful detection. Hence the map must be injective.
\end{proof}
Neutrality is a condition against false positive arrows, faithfulness a condition against completely hidden arrows, and Theorem~\ref{thm:hidden-decomposition} gives the stronger pair-specific condition for retaining all decision information. They should not be conflated. An observation can reveal a weak but nonzero arrow while losing most of the available directional information.
\section{What the protocol theorem adds to the structural problem}
The protocol algebra identifies exactly where observational asymmetry can enter and how it composes. It permits cancellation, singular supports and arbitrary record memory. It also specifies the minimal calibration required to interpret reversal of a measured history as a test of the underlying source. Together with the clock-measure law and the causal-descent obstruction reconstructed from X\={o}riun \cite{Xoriun2026}, it rules out several apparent explanations that merely transfer temporal orientation into a clock, an apparatus, a future-only geometry or a selection rule. It does not supply the probability law whose asymmetric boundary conditions still require physical explanation.