Download chips/yosys/passes/techmap/extract_counter.cc from STAR-future/Trinity-SciData: direct link, hf CLI and curl.
- Browser
- Download file 26 kB
-
https://huggingface.co/datasets/STAR-future/Trinity-SciData/resolve/main/chips/yosys/passes/techmap/extract_counter.cc
- Command line
-
hf download hf://datasets/STAR-future/Trinity-SciData/chips/yosys/passes/techmap/extract_counter.cc
-
curl -L -o extract_counter.cc https://huggingface.co/datasets/STAR-future/Trinity-SciData/resolve/main/chips/yosys/passes/techmap/extract_counter.cc
26 kB
| /* | |
| * yosys -- Yosys Open SYnthesis Suite | |
| * | |
| * Copyright (C) 2017 Claire Xenia Wolf <claire@yosyshq.com> | |
| * | |
| * Permission to use, copy, modify, and/or distribute this software for any | |
| * purpose with or without fee is hereby granted, provided that the above | |
| * copyright notice and this permission notice appear in all copies. | |
| * | |
| * THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES | |
| * WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF | |
| * MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR | |
| * ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES | |
| * WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN | |
| * ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF | |
| * OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. | |
| * | |
| */ | |
| USING_YOSYS_NAMESPACE | |
| PRIVATE_NAMESPACE_BEGIN | |
| //get the list of cells hooked up to at least one bit of a given net | |
| pool<Cell*> get_other_cells(const RTLIL::SigSpec& port, ModIndex& index, Cell* src) | |
| { | |
| pool<Cell*> rval; | |
| for(auto b : port) | |
| { | |
| pool<ModIndex::PortInfo> ports = index.query_ports(b); | |
| for(auto x : ports) | |
| { | |
| if(x.cell == src) | |
| continue; | |
| rval.insert(x.cell); | |
| } | |
| } | |
| return rval; | |
| } | |
| //return true if there is a full-width bus connection from cell a port ap to cell b port bp | |
| //if other_conns_allowed is false, then we require a strict point to point connection (no other links) | |
| bool is_full_bus( | |
| const RTLIL::SigSpec& sig, | |
| ModIndex& index, | |
| Cell* a, | |
| RTLIL::IdString ap, | |
| Cell* b, | |
| RTLIL::IdString bp, | |
| bool other_conns_allowed = false) | |
| { | |
| for(auto s : sig) | |
| { | |
| pool<ModIndex::PortInfo> ports = index.query_ports(s); | |
| bool found_a = false; | |
| bool found_b = false; | |
| for(auto x : ports) | |
| { | |
| if( (x.cell == a) && (x.port == ap) ) | |
| found_a = true; | |
| else if( (x.cell == b) && (x.port == bp) ) | |
| found_b = true; | |
| else if(!other_conns_allowed) | |
| return false; | |
| } | |
| if( (!found_a) || (!found_b) ) | |
| return false; | |
| } | |
| return true; | |
| } | |
| //return true if the signal connects to one port only (nothing on the other end) | |
| bool is_unconnected(const RTLIL::SigSpec& port, ModIndex& index) | |
| { | |
| for(auto b : port) | |
| { | |
| pool<ModIndex::PortInfo> ports = index.query_ports(b); | |
| if(ports.size() > 1) | |
| return false; | |
| } | |
| return true; | |
| } | |
| struct CounterExtraction | |
| { | |
| int width; //counter width | |
| bool count_is_up; //count up (else down) | |
| RTLIL::Wire* rwire; //the register output | |
| bool has_reset; //true if we have a reset | |
| bool has_ce; //true if we have a clock enable | |
| bool ce_inverted; //true if clock enable is active low | |
| RTLIL::SigSpec rst; //reset pin | |
| bool rst_inverted; //true if reset is active low | |
| bool rst_to_max; //true if we reset to max instead of 0 | |
| int count_value; //value we count from | |
| RTLIL::SigSpec ce; //clock signal | |
| RTLIL::SigSpec clk; //clock enable, if any | |
| RTLIL::SigSpec outsig; //counter overflow output signal | |
| RTLIL::SigSpec poutsig; //counter parallel output signal | |
| bool has_pout; //whether parallel output is used | |
| RTLIL::Cell* count_mux; //counter mux | |
| RTLIL::Cell* count_reg; //counter register | |
| RTLIL::Cell* overflow_cell; //cell for counter overflow (either inverter reduction or $eq) | |
| pool<ModIndex::PortInfo> pouts; //Ports that take a parallel output from us | |
| }; | |
| struct CounterExtractionSettings | |
| { | |
| pool<RTLIL::IdString>& parallel_cells; | |
| int maxwidth; | |
| int minwidth; | |
| bool allow_arst; | |
| int allowed_dirs; //0 = down, 1 = up, 2 = both | |
| }; | |
| //attempt to extract a counter centered on the given adder cell | |
| int counter_tryextract( | |
| ModIndex& index, | |
| Cell *cell, | |
| CounterExtraction& extract, | |
| CounterExtractionSettings settings) | |
| { | |
| SigMap& sigmap = index.sigmap; | |
| //Both inputs must be unsigned, so don't extract anything with a signed input | |
| bool a_sign = cell->getParam(ID::A_SIGNED).as_bool(); | |
| bool b_sign = cell->getParam(ID::B_SIGNED).as_bool(); | |
| if(a_sign || b_sign) | |
| return 3; | |
| //CO and X must be unconnected (exactly one connection to each port) | |
| if(!is_unconnected(sigmap(cell->getPort(ID::CO)), index)) | |
| return 7; | |
| if(!is_unconnected(sigmap(cell->getPort(ID::X)), index)) | |
| return 8; | |
| //true if $alu is performing A - B, else A + B | |
| bool alu_is_subtract; | |
| //BI and CI must be both constant 0 or both constant 1 as well | |
| const RTLIL::SigSpec bi_port = sigmap(cell->getPort(ID::BI)); | |
| const RTLIL::SigSpec ci_port = sigmap(cell->getPort(ID::CI)); | |
| if(bi_port.is_fully_const() && bi_port.as_int() == 1 && | |
| ci_port.is_fully_const() && ci_port.as_int() == 1) | |
| { | |
| alu_is_subtract = true; | |
| } | |
| else if(bi_port.is_fully_const() && bi_port.as_int() == 0 && | |
| ci_port.is_fully_const() && ci_port.as_int() == 0) | |
| { | |
| alu_is_subtract = false; | |
| } | |
| else | |
| { | |
| return 5; | |
| } | |
| //false -> port B connects to value | |
| //true -> port A connects to value | |
| bool alu_port_use_a = false; | |
| if(alu_is_subtract) | |
| { | |
| const int a_width = cell->getParam(ID::A_WIDTH).as_int(); | |
| const int b_width = cell->getParam(ID::B_WIDTH).as_int(); | |
| const RTLIL::SigSpec b_port = sigmap(cell->getPort(ID::B)); | |
| // down, cnt <= cnt - 1 | |
| if (b_width == 1 && b_port.is_fully_const() && b_port.as_int() == 1) | |
| { | |
| // OK | |
| alu_port_use_a = true; | |
| extract.count_is_up = false; | |
| } | |
| // up, cnt <= cnt - -1 | |
| else if (b_width == a_width && b_port.is_fully_const() && b_port.is_fully_ones()) | |
| { | |
| // OK | |
| alu_port_use_a = true; | |
| extract.count_is_up = true; | |
| } | |
| // ??? | |
| else | |
| { | |
| return 2; | |
| } | |
| } | |
| else | |
| { | |
| const int a_width = cell->getParam(ID::A_WIDTH).as_int(); | |
| const int b_width = cell->getParam(ID::B_WIDTH).as_int(); | |
| const RTLIL::SigSpec a_port = sigmap(cell->getPort(ID::A)); | |
| const RTLIL::SigSpec b_port = sigmap(cell->getPort(ID::B)); | |
| // down, cnt <= cnt + -1 | |
| if (b_width == a_width && b_port.is_fully_const() && b_port.is_fully_ones()) | |
| { | |
| // OK | |
| alu_port_use_a = true; | |
| extract.count_is_up = false; | |
| } | |
| else if (a_width == b_width && a_port.is_fully_const() && a_port.is_fully_ones()) | |
| { | |
| // OK | |
| alu_port_use_a = false; | |
| extract.count_is_up = false; | |
| } | |
| // up, cnt <= cnt + 1 | |
| else if (b_width == 1 && b_port.is_fully_const() && b_port.as_int() == 1) | |
| { | |
| // OK | |
| alu_port_use_a = true; | |
| extract.count_is_up = true; | |
| } | |
| else if (a_width == 1 && a_port.is_fully_const() && a_port.as_int() == 1) | |
| { | |
| // OK | |
| alu_port_use_a = false; | |
| extract.count_is_up = true; | |
| } | |
| // ??? | |
| else | |
| { | |
| return 2; | |
| } | |
| } | |
| if (extract.count_is_up && settings.allowed_dirs == 0) | |
| return 26; | |
| if (!extract.count_is_up && settings.allowed_dirs == 1) | |
| return 26; | |
| //Check if counter is an appropriate size | |
| int count_width; | |
| if (alu_port_use_a) | |
| count_width = cell->getParam(ID::A_WIDTH).as_int(); | |
| else | |
| count_width = cell->getParam(ID::B_WIDTH).as_int(); | |
| extract.width = count_width; | |
| if( (count_width < settings.minwidth) || (count_width > settings.maxwidth) ) | |
| return 1; | |
| //Y must have exactly one connection, and it has to be a $mux cell. | |
| //We must have a direct bus connection from our Y to their A. | |
| const RTLIL::SigSpec aluy = sigmap(cell->getPort(ID::Y)); | |
| pool<Cell*> y_loads = get_other_cells(aluy, index, cell); | |
| if(y_loads.size() != 1) | |
| return 9; | |
| Cell* count_mux = *y_loads.begin(); | |
| extract.count_mux = count_mux; | |
| if(count_mux->type != ID($mux)) | |
| return 10; | |
| if(!is_full_bus(aluy, index, cell, ID::Y, count_mux, ID::A)) | |
| return 11; | |
| if (extract.count_is_up) | |
| { | |
| //B connection of the mux must be 0 | |
| const RTLIL::SigSpec underflow = sigmap(count_mux->getPort(ID::B)); | |
| if(!(underflow.is_fully_const() && underflow.is_fully_zero())) | |
| return 12; | |
| } | |
| else | |
| { | |
| //B connection of the mux is our underflow value | |
| const RTLIL::SigSpec underflow = sigmap(count_mux->getPort(ID::B)); | |
| if(!underflow.is_fully_const()) | |
| return 12; | |
| extract.count_value = underflow.as_int(); | |
| } | |
| //S connection of the mux must come from an inverter if down, eq if up | |
| //(need not be the only load) | |
| const RTLIL::SigSpec muxsel = sigmap(count_mux->getPort(ID::S)); | |
| extract.outsig = muxsel; | |
| pool<Cell*> muxsel_conns = get_other_cells(muxsel, index, count_mux); | |
| Cell* overflow_cell = NULL; | |
| for(auto c : muxsel_conns) | |
| { | |
| if(extract.count_is_up && c->type != ID($eq)) | |
| continue; | |
| if(!extract.count_is_up && c->type != ID($logic_not)) | |
| continue; | |
| if(!is_full_bus(muxsel, index, c, ID::Y, count_mux, ID::S, true)) | |
| continue; | |
| overflow_cell = c; | |
| break; | |
| } | |
| if(overflow_cell == NULL) | |
| return 13; | |
| extract.overflow_cell = overflow_cell; | |
| //Y connection of the mux must have exactly one load, the counter's internal register, if there's no clock enable | |
| //If we have a clock enable, Y drives the B input of a mux. A of that mux must come from our register | |
| const RTLIL::SigSpec muxy = sigmap(count_mux->getPort(ID::Y)); | |
| pool<Cell*> muxy_loads = get_other_cells(muxy, index, count_mux); | |
| if(muxy_loads.size() != 1) | |
| return 14; | |
| Cell* muxload = *muxy_loads.begin(); | |
| Cell* count_reg = muxload; | |
| Cell* cemux = NULL; | |
| RTLIL::SigSpec cey; | |
| if(muxload->type == ID($mux)) | |
| { | |
| //This mux is probably a clock enable mux. | |
| //Find our count register (should be our only load) | |
| cemux = muxload; | |
| cey = sigmap(cemux->getPort(ID::Y)); | |
| pool<Cell*> cey_loads = get_other_cells(cey, index, cemux); | |
| if(cey_loads.size() != 1) | |
| return 24; | |
| count_reg = *cey_loads.begin(); | |
| if(sigmap(cemux->getPort(ID::Y)) != sigmap(count_reg->getPort(ID::D))) | |
| return 24; | |
| //Mux should have A driven by count Q, and B by muxy | |
| //if A and B are swapped, CE polarity is inverted | |
| if(sigmap(cemux->getPort(ID::B)) == muxy && | |
| sigmap(cemux->getPort(ID::A)) == sigmap(count_reg->getPort(ID::Q))) | |
| { | |
| extract.ce_inverted = false; | |
| } | |
| else if(sigmap(cemux->getPort(ID::A)) == muxy && | |
| sigmap(cemux->getPort(ID::B)) == sigmap(count_reg->getPort(ID::Q))) | |
| { | |
| extract.ce_inverted = true; | |
| } | |
| else | |
| { | |
| return 24; | |
| } | |
| //Select of the mux is our clock enable | |
| extract.has_ce = true; | |
| extract.ce = sigmap(cemux->getPort(ID::S)); | |
| } | |
| else | |
| extract.has_ce = false; | |
| extract.count_reg = count_reg; | |
| if(count_reg->type == ID($dff)) | |
| extract.has_reset = false; | |
| else if(count_reg->type == ID($adff)) | |
| { | |
| if (!settings.allow_arst) | |
| return 25; | |
| extract.has_reset = true; | |
| //Check polarity of reset - we may have to add an inverter later on! | |
| extract.rst_inverted = (count_reg->getParam(ID::ARST_POLARITY).as_int() != 1); | |
| //Verify ARST_VALUE is zero or full scale | |
| int rst_value = count_reg->getParam(ID::ARST_VALUE).as_int(); | |
| if(rst_value == 0) | |
| extract.rst_to_max = false; | |
| else if(rst_value == extract.count_value) | |
| extract.rst_to_max = true; | |
| else | |
| return 23; | |
| //Save the reset | |
| extract.rst = sigmap(count_reg->getPort(ID::ARST)); | |
| } | |
| //TODO: support synchronous reset | |
| else | |
| return 15; | |
| //Sanity check that we use the ALU output properly | |
| if(extract.has_ce) | |
| { | |
| if(!extract.ce_inverted && !is_full_bus(muxy, index, count_mux, ID::Y, cemux, ID::B)) | |
| return 16; | |
| if(extract.ce_inverted && !is_full_bus(muxy, index, count_mux, ID::Y, cemux, ID::A)) | |
| return 16; | |
| if(!is_full_bus(cey, index, cemux, ID::Y, count_reg, ID::D)) | |
| return 16; | |
| } | |
| else if(!is_full_bus(muxy, index, count_mux, ID::Y, count_reg, ID::D)) | |
| return 16; | |
| //TODO: Verify count_reg CLK_POLARITY is 1 | |
| //Register output must have exactly two loads, the inverter and ALU | |
| //(unless we have a parallel output!) | |
| //If we have a clock enable, 3 is OK | |
| const RTLIL::SigSpec qport = count_reg->getPort(ID::Q); | |
| extract.poutsig = qport; | |
| extract.has_pout = false; | |
| const RTLIL::SigSpec cnout = sigmap(qport); | |
| pool<Cell*> cnout_loads = get_other_cells(cnout, index, count_reg); | |
| unsigned int max_loads = 2; | |
| if(extract.has_ce) | |
| max_loads = 3; | |
| if(cnout_loads.size() > max_loads) | |
| { | |
| for(auto c : cnout_loads) | |
| { | |
| if(c == overflow_cell) | |
| continue; | |
| if(c == cell) | |
| continue; | |
| if(c == muxload) | |
| continue; | |
| //If we specified a limited set of cells for parallel output, check that we only drive them | |
| if(!settings.parallel_cells.empty()) | |
| { | |
| //Make sure we're in the whitelist | |
| if( settings.parallel_cells.find(c->type) == settings.parallel_cells.end()) | |
| return 17; | |
| } | |
| //Figure out what port(s) are driven by it | |
| //TODO: this can probably be done more efficiently w/o multiple iterations over our whole net? | |
| //TODO: For what purpose do we actually need extract.pouts? | |
| for(auto b : qport) | |
| { | |
| pool<ModIndex::PortInfo> ports = index.query_ports(b); | |
| for(auto x : ports) | |
| { | |
| if(x.cell != c) | |
| continue; | |
| extract.pouts.insert(ModIndex::PortInfo(c, x.port, 0)); | |
| extract.has_pout = true; | |
| } | |
| } | |
| } | |
| } | |
| for (auto b : qport) | |
| { | |
| if(index.query_is_output(b)) | |
| { | |
| // Parallel out goes out of module | |
| extract.has_pout = true; | |
| } | |
| } | |
| if(!extract.count_is_up) | |
| { | |
| if(!is_full_bus(cnout, index, count_reg, ID::Q, overflow_cell, ID::A, true)) | |
| return 18; | |
| } | |
| else | |
| { | |
| if(is_full_bus(cnout, index, count_reg, ID::Q, overflow_cell, ID::A, true)) | |
| { | |
| // B must be the overflow value | |
| const RTLIL::SigSpec overflow = sigmap(overflow_cell->getPort(ID::B)); | |
| if(!overflow.is_fully_const()) | |
| return 12; | |
| extract.count_value = overflow.as_int(); | |
| } | |
| else if(is_full_bus(cnout, index, count_reg, ID::Q, overflow_cell, ID::B, true)) | |
| { | |
| // A must be the overflow value | |
| const RTLIL::SigSpec overflow = sigmap(overflow_cell->getPort(ID::A)); | |
| if(!overflow.is_fully_const()) | |
| return 12; | |
| extract.count_value = overflow.as_int(); | |
| } | |
| else | |
| { | |
| return 18; | |
| } | |
| } | |
| if(alu_port_use_a && !is_full_bus(cnout, index, count_reg, ID::Q, cell, ID::A, true)) | |
| return 19; | |
| if(!alu_port_use_a && !is_full_bus(cnout, index, count_reg, ID::Q, cell, ID::B, true)) | |
| return 19; | |
| //Look up the clock from the register | |
| extract.clk = sigmap(count_reg->getPort(ID::CLK)); | |
| if(!extract.count_is_up) | |
| { | |
| //Register output net must have an INIT attribute equal to the count value | |
| extract.rwire = cnout.as_wire(); | |
| if(extract.rwire->attributes.find(ID::init) == extract.rwire->attributes.end()) | |
| return 20; | |
| int rinit = extract.rwire->attributes[ID::init].as_int(); | |
| if(rinit != extract.count_value) | |
| return 21; | |
| } | |
| else | |
| { | |
| //Register output net must not have an INIT attribute or it must be zero | |
| extract.rwire = cnout.as_wire(); | |
| if(extract.rwire->attributes.find(ID::init) == extract.rwire->attributes.end()) | |
| return 0; | |
| int rinit = extract.rwire->attributes[ID::init].as_int(); | |
| if(rinit != 0) | |
| return 21; | |
| } | |
| return 0; | |
| } | |
| void counter_worker( | |
| ModIndex& index, | |
| Cell *cell, | |
| unsigned int& total_counters, | |
| pool<Cell*>& cells_to_remove, | |
| pool<pair<Cell*, string>>& cells_to_rename, | |
| CounterExtractionSettings settings) | |
| { | |
| SigMap& sigmap = index.sigmap; | |
| //Core of the counter must be an ALU | |
| if (cell->type != ID($alu)) | |
| return; | |
| //A input is the count value. Check if it has COUNT_EXTRACT set. | |
| //If it's not a wire, don't even try | |
| auto port = sigmap(cell->getPort(ID::A)); | |
| if(!port.is_wire()) | |
| { | |
| port = sigmap(cell->getPort(ID::B)); | |
| if(!port.is_wire()) | |
| return; | |
| } | |
| RTLIL::Wire* port_wire = port.as_wire(); | |
| bool force_extract = false; | |
| bool never_extract = false; | |
| string count_reg_src = port_wire->attributes[ID::src].decode_string().c_str(); | |
| if(port_wire->attributes.find(ID(COUNT_EXTRACT)) != port_wire->attributes.end()) | |
| { | |
| pool<string> sa = port_wire->get_strpool_attribute(ID(COUNT_EXTRACT)); | |
| string extract_value; | |
| if(sa.size() >= 1) | |
| { | |
| extract_value = *sa.begin(); | |
| log(" Signal %s declared at %s has COUNT_EXTRACT = %s\n", | |
| port_wire, | |
| count_reg_src, | |
| extract_value); | |
| if(extract_value == "FORCE") | |
| force_extract = true; | |
| else if(extract_value == "NO") | |
| never_extract = true; | |
| else if(extract_value == "AUTO") | |
| {} //default | |
| else | |
| log_error(" Illegal COUNT_EXTRACT value %s (must be one of FORCE, NO, AUTO)\n", | |
| extract_value); | |
| } | |
| } | |
| //If we're explicitly told not to extract, don't infer a counter | |
| if(never_extract) | |
| return; | |
| //Attempt to extract a counter | |
| CounterExtraction extract; | |
| int reason = counter_tryextract(index, cell, extract, settings); | |
| //Nonzero code - we could not find a matchable counter. | |
| //Do nothing, unless extraction was forced in which case give an error | |
| if(reason != 0) | |
| { | |
| static const char* reasons[]= | |
| { | |
| "no problem", //0 | |
| "counter is too large/small", //1 | |
| "counter does not count by one", //2 | |
| "counter uses signed math", //3 | |
| "RESERVED, not implemented", //4 | |
| "ALU is not an adder/subtractor", //5 | |
| "RESERVED, not implemented", //6 | |
| "ALU ports used outside counter", //7 | |
| "ALU ports used outside counter", //8 | |
| "ALU output used outside counter", //9 | |
| "ALU output is not a mux", //10 | |
| "ALU output is not full bus", //11 | |
| "Underflow value is not constant", //12 | |
| "No underflow detector found", //13 | |
| "Mux output is used outside counter", //14 | |
| "Counter reg is not DFF/ADFF", //15 | |
| "Counter input is not full bus", //16 | |
| "Count register is used outside counter, but not by an allowed cell", //17 | |
| "Register output is not full bus", //18 | |
| "Register output is not full bus", //19 | |
| "No init value found", //20 | |
| "Underflow value is not equal to init value", //21 | |
| "RESERVED, not implemented", //22, kept for compatibility but not used anymore | |
| "Reset is not to zero or COUNT_TO", //23 | |
| "Clock enable configuration is unsupported", //24 | |
| "Async reset used but not permitted", //25 | |
| "Count direction is not allowed" //26 | |
| }; | |
| if(force_extract) | |
| { | |
| log_error( | |
| "Counter extraction is set to FORCE on register %s, but a counter could not be inferred (%s)\n", | |
| port_wire, | |
| reasons[reason]); | |
| } | |
| return; | |
| } | |
| //Get new cell name | |
| string countname = string("$COUNTx$") + extract.rwire->name.unescape(); | |
| //Wipe all of the old connections to the ALU | |
| cell->unsetPort(ID::A); | |
| cell->unsetPort(ID::B); | |
| cell->unsetPort(ID::BI); | |
| cell->unsetPort(ID::CI); | |
| cell->unsetPort(ID::CO); | |
| cell->unsetPort(ID::X); | |
| cell->unsetPort(ID::Y); | |
| cell->unsetParam(ID::A_SIGNED); | |
| cell->unsetParam(ID::A_WIDTH); | |
| cell->unsetParam(ID::B_SIGNED); | |
| cell->unsetParam(ID::B_WIDTH); | |
| cell->unsetParam(ID::Y_WIDTH); | |
| //Change the cell type | |
| cell->type = ID($__COUNT_); | |
| //Hook up resets | |
| if(extract.has_reset) | |
| { | |
| //TODO: support other kinds of reset | |
| cell->setParam(ID(RESET_MODE), RTLIL::Const("LEVEL")); | |
| //If the reset is active low, infer an inverter ($__COUNT_ cells always have active high reset) | |
| if(extract.rst_inverted) | |
| { | |
| auto realreset = cell->module->addWire(NEW_ID); | |
| cell->module->addNot(NEW_ID, extract.rst, RTLIL::SigSpec(realreset)); | |
| cell->setPort(ID(RST), realreset); | |
| } | |
| else | |
| cell->setPort(ID(RST), extract.rst); | |
| } | |
| else | |
| { | |
| cell->setParam(ID(RESET_MODE), RTLIL::Const("RISING")); | |
| cell->setPort(ID(RST), RTLIL::SigSpec(false)); | |
| } | |
| //Hook up other stuff | |
| //cell->setParam(ID(CLKIN_DIVIDE), RTLIL::Const(1)); | |
| cell->setParam(ID(COUNT_TO), RTLIL::Const(extract.count_value)); | |
| cell->setParam(ID::WIDTH, RTLIL::Const(extract.width)); | |
| cell->setPort(ID::CLK, extract.clk); | |
| cell->setPort(ID(OUT), extract.outsig); | |
| //Hook up clock enable | |
| if(extract.has_ce) | |
| { | |
| cell->setParam(ID(HAS_CE), RTLIL::Const(1)); | |
| if(extract.ce_inverted) | |
| { | |
| auto realce = cell->module->addWire(NEW_ID); | |
| cell->module->addNot(NEW_ID, extract.ce, RTLIL::SigSpec(realce)); | |
| cell->setPort(ID(CE), realce); | |
| } | |
| else | |
| cell->setPort(ID(CE), extract.ce); | |
| } | |
| else | |
| { | |
| cell->setParam(ID(HAS_CE), RTLIL::Const(0)); | |
| cell->setPort(ID(CE), RTLIL::Const(1)); | |
| } | |
| if(extract.count_is_up) | |
| { | |
| cell->setParam(ID(DIRECTION), RTLIL::Const("UP")); | |
| //XXX: What is this supposed to do? | |
| cell->setPort(ID(UP), RTLIL::Const(1)); | |
| } | |
| else | |
| { | |
| cell->setParam(ID(DIRECTION), RTLIL::Const("DOWN")); | |
| cell->setPort(ID(UP), RTLIL::Const(0)); | |
| } | |
| //Hook up hard-wired ports, default to no parallel output | |
| cell->setParam(ID(HAS_POUT), RTLIL::Const(0)); | |
| cell->setParam(ID(RESET_TO_MAX), RTLIL::Const(0)); | |
| //Hook up any parallel outputs | |
| for(auto load : extract.pouts) | |
| { | |
| log(" Counter has parallel output to cell %s port %s\n", cell, PooledName(load.cell->module, load.port).unescape()); | |
| } | |
| if(extract.has_pout) | |
| { | |
| //Connect it to our parallel output | |
| cell->setPort(ID(POUT), extract.poutsig); | |
| cell->setParam(ID(HAS_POUT), RTLIL::Const(1)); | |
| } | |
| //Delete the cells we've replaced (let opt_clean handle deleting the now-redundant wires) | |
| cells_to_remove.insert(extract.count_mux); | |
| cells_to_remove.insert(extract.count_reg); | |
| cells_to_remove.insert(extract.overflow_cell); | |
| //Log it | |
| total_counters ++; | |
| string reset_type = "non-resettable"; | |
| if(extract.has_reset) | |
| { | |
| if(extract.rst_inverted) | |
| reset_type = "negative"; | |
| else | |
| reset_type = "positive"; | |
| //TODO: support other kind of reset | |
| reset_type += " async resettable"; | |
| } | |
| log(" Found %d-bit (%s) %s counter %s (counting %s %d) for register %s, declared at %s\n", | |
| extract.width, | |
| reset_type, | |
| extract.count_is_up ? "up" : "down", | |
| countname, | |
| extract.count_is_up ? "to" : "from", | |
| extract.count_value, | |
| extract.rwire->name.unescape(), | |
| count_reg_src); | |
| //Optimize the counter | |
| //If we have no parallel output, and we have redundant bits, shrink us | |
| if(!extract.has_pout) | |
| { | |
| //TODO: Need to update this when we add support for counters with nonzero reset values | |
| //to make sure the reset value fits in our bit space too | |
| //Optimize it | |
| int newbits = ceil(log2(extract.count_value)); | |
| if(extract.width != newbits) | |
| { | |
| cell->setParam(ID::WIDTH, RTLIL::Const(newbits)); | |
| log(" Optimizing out %d unused high-order bits (new width is %d)\n", | |
| extract.width - newbits, | |
| newbits); | |
| } | |
| } | |
| //Finally, rename the cell | |
| cells_to_rename.insert(pair<Cell*, string>(cell, countname)); | |
| } | |
| struct ExtractCounterPass : public Pass { | |
| ExtractCounterPass() : Pass("extract_counter", "Extract GreenPak4 counter cells") { } | |
| void help() override | |
| { | |
| // |---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---| | |
| log("\n"); | |
| log(" extract_counter [options] [selection]\n"); | |
| log("\n"); | |
| log("This pass converts non-resettable or async resettable counters to counter cells.\n"); | |
| log("Use a target-specific 'techmap' map file to convert those cells to the actual\n"); | |
| log("target cells.\n"); | |
| log("\n"); | |
| log(" -maxwidth N\n"); | |
| log(" Only extract counters up to N bits wide (default 64)\n"); | |
| log("\n"); | |
| log(" -minwidth N\n"); | |
| log(" Only extract counters at least N bits wide (default 2)\n"); | |
| log("\n"); | |
| log(" -allow_arst yes|no\n"); | |
| log(" Allow counters to have async reset (default yes)\n"); | |
| log("\n"); | |
| log(" -dir up|down|both\n"); | |
| log(" Look for up-counters, down-counters, or both (default down)\n"); | |
| log("\n"); | |
| log(" -pout X,Y,...\n"); | |
| log(" Only allow parallel output from the counter to the listed cell types\n"); | |
| log(" (if not specified, parallel outputs are not restricted)\n"); | |
| log("\n"); | |
| log("\n"); | |
| } | |
| void execute(std::vector<std::string> args, RTLIL::Design *design) override | |
| { | |
| log_header(design, "Executing EXTRACT_COUNTER pass (find counters in netlist).\n"); | |
| pool<RTLIL::IdString> _parallel_cells; | |
| CounterExtractionSettings settings | |
| { | |
| _parallel_cells, // parallel_cells | |
| 64, // maxwidth | |
| 2, // minwidth | |
| true, // allow_arst | |
| 0, // allowed_dirs | |
| }; | |
| size_t argidx; | |
| for (argidx = 1; argidx < args.size(); argidx++) | |
| { | |
| if (args[argidx] == "-pout") | |
| { | |
| if(argidx + 1 >= args.size()) | |
| { | |
| log_error("extract_counter -pout requires an argument\n"); | |
| return; | |
| } | |
| std::string pouts = args[++argidx]; | |
| std::string tmp; | |
| for(size_t i=0; i<pouts.length(); i++) | |
| { | |
| if(pouts[i] == ',') | |
| { | |
| settings.parallel_cells.insert(design->twines().add(RTLIL::escape_id(tmp))); | |
| tmp = ""; | |
| } | |
| else | |
| tmp += pouts[i]; | |
| } | |
| settings.parallel_cells.insert(design->twines().add(RTLIL::escape_id(tmp))); | |
| continue; | |
| } | |
| if (args[argidx] == "-maxwidth" && argidx+1 < args.size()) | |
| { | |
| settings.maxwidth = atoi(args[++argidx].c_str()); | |
| continue; | |
| } | |
| if (args[argidx] == "-minwidth" && argidx+1 < args.size()) | |
| { | |
| settings.minwidth = atoi(args[++argidx].c_str()); | |
| continue; | |
| } | |
| if (args[argidx] == "-allow_arst" && argidx+1 < args.size()) | |
| { | |
| auto arg = args[++argidx]; | |
| if (arg == "yes") | |
| settings.allow_arst = true; | |
| else if (arg == "no") | |
| settings.allow_arst = false; | |
| else | |
| log_error("Invalid -allow_arst value \"%s\"\n", arg); | |
| continue; | |
| } | |
| if (args[argidx] == "-dir" && argidx+1 < args.size()) | |
| { | |
| auto arg = args[++argidx]; | |
| if (arg == "up") | |
| settings.allowed_dirs = 1; | |
| else if (arg == "down") | |
| settings.allowed_dirs = 0; | |
| else if (arg == "both") | |
| settings.allowed_dirs = 2; | |
| else | |
| log_error("Invalid -dir value \"%s\"\n", arg); | |
| continue; | |
| } | |
| } | |
| extra_args(args, argidx, design); | |
| if (settings.minwidth < 2) | |
| { | |
| //A counter with less than 2 bits makes no sense | |
| log_warning("Minimum counter width is 2 bits wide\n"); | |
| settings.minwidth = 2; | |
| } | |
| //Extract all of the counters we could find | |
| unsigned int total_counters = 0; | |
| for (auto module : design->selected_modules()) | |
| { | |
| pool<Cell*> cells_to_remove; | |
| pool<pair<Cell*, string>> cells_to_rename; | |
| ModIndex index(module); | |
| for (auto cell : module->selected_cells()) | |
| counter_worker(index, cell, total_counters, cells_to_remove, cells_to_rename, settings); | |
| for(auto cell : cells_to_remove) | |
| { | |
| //log("Removing cell %s\n", cell); | |
| module->remove(cell); | |
| } | |
| for(auto cpair : cells_to_rename) | |
| { | |
| //log("Renaming cell %s to %s\n", cpair.first, cpair.second); | |
| module->rename(cpair.first, cpair.second); | |
| } | |
| } | |
| if(total_counters) | |
| log("Extracted %u counters\n", total_counters); | |
| } | |
| } ExtractCounterPass; | |
| PRIVATE_NAMESPACE_END | |