function [Nsamp] = EstimateRequiredSamples(Pc,acc,conf,maxiter)
%
% Estimate the number of samples required for a Monte Carlo (MC) simulation
% to achieve a Pc-estimation accuracy of 0 < acc < 1, to a confidence level
% of 0 < conf < 1.
%
% INPUT:
%
% Pc = Pc to use for estimation process (typically a 2DPc value)
% acc = Desired accuracy for the MC Pc estimate (typically 0.1 or 0.3)
% conf = Confidence level for the accuracy estimate (typically 0.95)
% maxiter = Maximum number of iterations for binofit analysis [optional]
% (maxiter <= 0) => Perform no binofit iterations
% (maxiter > 0) => Perform at most maxiter binofit iterations
% [default maxiter = 100; typical number of iterations 3 to 10]
%
% OUTPUT:
%
% Nsamp = Recommended number of MC samples to achieve an MC estimation
% of a probability value 'Pc' with an accuracy of 'acc' at a
% confidence level of 'conf.'
%
% Check for sufficient input
Nargin = nargin;
if Nargin < 3
error('Insufficient input');
end
% Return infinity for non-positive Pc
if Pc <= 0
Nsamp = Inf;
return;
end
% Check for valid accuracy and confidence inputs
if (acc <= 0) || (acc >= 1)
error('The input desired accuracy must be 0 <= acc <= 1, typically 0.1 or 0.3');
end
if (conf <= 0) || (conf >= 1)
error('The input desired confidence must be 0 <= confidence <= 1, typically 0.95 or 0.99');
end
% Set default maximum iterations
if (Nargin < 4) || isempty(maxiter) || isnan(maxiter)
maxiter = 100;
elseif (maxiter < 0) || isinf(maxiter)
error('Invalid maxiter parameter, typically 100');
end
% Calculate the number of sigmas correspond to the confidence interval
% (for a chi-squared distribution with one degree of freedom)
use_statistics_toolbox = license('test','statistics_toolbox');
if use_statistics_toolbox
% Calculate Nsig using chi2inv
Nsig = sqrt(chi2inv(conf,1));
else
% Use zeroth iteration estimate without stats toolbox
maxiter = 0;
% Approximate Nsig using table interpolations
if conf < 1e-2
% For very small confidences < 0.01
% (likely never used, but here for completeness)
Nsig = 1.2533*conf;
elseif conf <= 9.99e-01
% For intermediate range confidences: 0.01 to 0.999
cn = [ ...
1.0000e-02 1.2533e-02; ...
1.0000e-01 1.2566e-01; ...
2.0000e-01 2.5335e-01; ...
3.0000e-01 3.8532e-01; ...
4.0000e-01 5.2440e-01; ...
5.0000e-01 6.7449e-01; ...
6.0000e-01 8.4162e-01; ...
6.8269e-01 1.0000e+00; ...
7.0000e-01 1.0364e+00; ...
8.0000e-01 1.2816e+00; ...
8.5000e-01 1.4395e+00; ...
9.0000e-01 1.6449e+00; ...
9.3000e-01 1.8119e+00; ...
9.5000e-01 1.9600e+00; ...
9.6000e-01 2.0537e+00; ...
9.7000e-01 2.1701e+00; ...
9.8000e-01 2.3263e+00; ...
9.9000e-01 2.5758e+00; ...
9.9500e-01 2.8070e+00; ...
9.9900e-01 3.2905e+00];
Nsig = interp1(cn(:,1),cn(:,2),conf);
elseif 1-conf >= 1e-11
% For confidences within 1e-11 to 1e-3 of one
% (likely never used, but here for completeness)
c = log10(1-conf);
cn = [ ...
-3.0000e+00 3.2905e+00; ...
-4.0000e+00 3.8906e+00; ...
-5.0000e+00 4.4172e+00; ...
-6.0000e+00 4.8916e+00; ...
-7.0000e+00 5.3267e+00; ...
-8.0000e+00 5.7307e+00; ...
-9.0000e+00 6.1094e+00; ...
-1.0000e+01 6.4670e+00; ...
-1.1000e+01 6.8065e+00];
Nsig = interp1(cn(:,1),cn(:,2),c);
else
error('Confidence out of tabulated range');
end
end
% Calculate the approximate number of samples to achieve the accuracy at
% the 1-sigma confidence level
Nc1sig = 1/acc^2;
Ns1sig = Nc1sig/Pc;
% Adjust to calculate at the specified confidence interval
Ns0 = max(1,ceil(Nsig^2 * Ns1sig));
Ls = floor(log10(Ns0));
if (Ls > 1)
Ls = Ls-1;
end
Ms = 10^Ls;
Ns1 = ceil(Ns0/Ms);
Ns = Ns1*Ms;
% Adjust to make binofit return both one-sided accuracies to within the
% specified accuracy at the specified confidence
if (maxiter > 0)
% Calculate the alpha value from the confidence
alpha = (1-conf);
% Make the iteration increment for Nsamp approximately 3%
del = max(1,ceil(0.03*Ns1));
% Iterate until binofit indicates the desired accuracy has been
% achieved, or the maximum iteration number has been exceeded.
niter = 0;
iterating = true;
while iterating
% Calculate binofit confidence interval, Pclo < Pc < Pchi
if use_statistics_toolbox
[~,Pclohi] = binofit(round(Pc*Ns),Ns,alpha);
else
Pclohi = sqrt(round(Pc*Ns))/Ns;
end
% disp(['Ns = ' num2str(Ns) ' Acc = ' num2str(max(abs(Pclohi-Pc))/Pc)]);
niter = niter+1;
% Ensure the estimated accuracy is less than the desired accuracy
% on both the low and high sides of the interval
if max(abs(Pclohi-Pc)) > acc*Pc
% The desired accuracy has not been achieved, so increment
% the sample number
Ns = round(Ns/Ms+del)*Ms;
% Discontinue iterations if max value exceeded
if (niter >= maxiter)
iterating = false;
end
else
% The desired accuracy has been achieved, so stop iterating
iterating = false;
end
end
end
% Return final estimate for number of samples
Nsamp = Ns;
return;