Datasets:
File size: 10,931 Bytes
6928500 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 | ---
license: cc-by-nc-4.0
task_categories:
- tabular-classification
- tabular-regression
- time-series-forecasting
language:
- en
tags:
- tsfile
- timeseries
- time-series
- synthetic
- oil-and-gas
- midstream
- pipeline
- hydraulics
- darcy-weisbach
- swamee-jain
- leak-detection
- scada
- flow-assurance
- xpertsystems
- format:tsfile
pretty_name: OIL-024 — Synthetic Pipeline Flow Dataset (Sample) (TsFile)
size_categories:
- 100K<n<1M
configs:
- config_name: default
data_files:
- split: compressor_operations
path: compressor_operations.tsfile
- split: corrosion_erosion
path: corrosion_erosion.tsfile
- split: flow_assurance
path: flow_assurance.tsfile
- split: hydraulic_profiles
path: hydraulic_profiles.tsfile
- split: leak_detection
path: leak_detection.tsfile
- split: optimization_labels
path: optimization_labels.tsfile
- split: pipeline_master
path: pipeline_master.tsfile
- split: pump_station_operations
path: pump_station_operations.tsfile
- split: scada_telemetry
path: scada_telemetry.tsfile
- split: thermal_profiles
path: thermal_profiles.tsfile
- split: transient_events
path: transient_events.tsfile
- split: valve_operations
path: valve_operations.tsfile
---
# OIL-024 — Synthetic Pipeline Flow Dataset (Sample) (TsFile)
Apache TsFile version of [`xpertsystems/oil024-sample`](https://huggingface.co/datasets/xpertsystems/oil024-sample).
## Overview
A free, schema-identical preview of XpertSystems.ai's enterprise pipeline flow dataset for **hydraulic modeling, leak detection, flow assurance, SCADA telemetry analytics, pump/compressor optimization, and pipeline reliability ML**. The sample covers **55 pipelines** with **369 segments** across **10 pipeline types**, **10 fluid families**, **10 global regions**, and **7 terrain types**, with **150,137 rows** linked across **12 tables** spanning **7 days of 180-minute time- series**.
- **Tables:** 12 TsFile table(s), 150,137 rows in total.
- `compressor_operations`: 1,344 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.023000 (UTC)
- `corrosion_erosion`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `flow_assurance`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `hydraulic_profiles`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `leak_detection`: 3 rows, 2025-01-03 09:00:00 → 2025-01-03 21:00:00 (UTC)
- `optimization_labels`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `pipeline_master`: 369 rows, 1970-01-01 00:00:00 → 1970-01-01 00:00:00.368000 (UTC)
- `pump_station_operations`: 3,752 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.066000 (UTC)
- `scada_telemetry`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `thermal_profiles`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
- `transient_events`: 21 rows, 2025-01-01 06:00:00 → 2025-01-07 12:00:00 (UTC)
- `valve_operations`: 20,664 rows, 2025-01-01 00:00:00 → 2025-01-07 21:00:00.368000 (UTC)
## Schema (TsFile structure)
### `compressor_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `compressor_id` (string), `suction_pressure_psi` (double), `discharge_pressure_psi` (double), `compression_ratio` (double), `efficiency_pct` (double), `fuel_gas_mscfd` (double)
### `corrosion_erosion.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `segment_id` (string), `corrosion_rate_mpy` (double), `erosion_index` (double), `wall_loss_pct_est` (double), `leak_probability_score` (double), `integrity_state` (string)
### `flow_assurance.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `segment_id` (string), `wax_risk_score` (double), `hydrate_risk_score` (double), `slugging_risk_score` (double), `wax_deposition_thickness_mm` (double), `flow_assurance_state` (string)
### `hydraulic_profiles.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (13): `profile_id` (string), `pipeline_id` (string), `segment_id` (string), `pressure_psi` (double), `downstream_pressure_psi` (double), `pressure_drop_psi` (double), `flow_bpd` (double), `velocity_fps` (double), `reynolds_number` (double), `friction_factor` (double), `flow_regime` (string), `mass_balance_error_pct` (double), `event_active` (int64)
### `leak_detection.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `leak_id` (string), `pipeline_id` (string), `segment_id` (string), `leak_rate_bpd` (double), `pressure_signature_score` (double), `detection_delay_sec` (int64), `isolated_flag` (int64), `estimated_loss_bbl` (double)
### `optimization_labels.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `pipeline_id` (string), `segment_id` (string), `optimization_score` (double), `failure_risk_score` (double), `efficiency_grade` (string), `recommended_action` (string), `event_type` (string)
### `pipeline_master.tsfile`
- **Time** (INT64, milliseconds) — synthetic row index over the stable source order; this table has no clock column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (21): `pipeline_id` (string), `segment_id` (string), `pipeline_type` (string), `primary_fluid` (string), `region` (string), `terrain` (string), `segment_order` (int64), `length_km` (double), `diameter_in` (double), `wall_thickness_in` (double), `roughness_mm` (double), `elevation_start_ft` (double), `elevation_end_ft` (double), `material_grade` (string), `coating_type` (string), `insulation_type` (string), `install_year` (int64), `maop_psi` (double), `design_flow_bpd` (double), `pigging_capable` (int64), `scada_enabled` (int64)
### `pump_station_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `pipeline_id` (string), `station_id` (string), `rpm` (double), `efficiency_pct` (double), `suction_pressure_psi` (double), `discharge_pressure_psi` (double), `power_kw` (double), `cavitation_risk_score` (double)
### `scada_telemetry.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (9): `pipeline_id` (string), `segment_id` (string), `sensor_id` (string), `sensor_type` (string), `signal_value` (double), `engineering_unit` (string), `telemetry_latency_ms` (int64), `quality_flag` (string), `drift_flag` (int64)
### `thermal_profiles.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (8): `thermal_id` (string), `pipeline_id` (string), `segment_id` (string), `temperature_f` (double), `ambient_temp_f` (double), `heat_loss_btu_hr_ft` (double), `thermal_gradient_f_per_km` (double), `joule_thomson_cooling_f` (double)
### `transient_events.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (7): `event_id` (string), `pipeline_id` (string), `event_type` (string), `event_duration_min` (int64), `operator_response_delay_sec` (double), `severity_score` (double), `root_cause` (string)
### `valve_operations.tsfile`
- **Time** (INT64, milliseconds) — the source `timestamp` column.
- **TAG**: none — the table is stored as a single device.
- **FIELD** (6): `pipeline_id` (string), `segment_id` (string), `valve_id` (string), `valve_position_pct` (double), `throttling_state` (int64), `response_latency_sec` (double)
## Conversion notes
- One TsFile per source CSV (12 tables); each table is stored as a single device, so the rig / well / tank / equipment / sensor identifiers stay ordinary FIELDs.
- Time = the table's own clock column as INT64 milliseconds (event timestamps, sample or inspection dates, and daily record dates). The clock columns used here are `timestamp`.
- Tables with no clock column (`pipeline_master`) use a synthetic row index over their stable source order as Time.
- No column is dropped. Rows that share a timestamp are ordered by a 1 ms step in stable source order, so daily tables keep their exact calendar day.
## Usage
> **Read this dataset with the Java SDK.** It is written with the `zstd` compressor. The Apache TsFile Java SDK reads every compressor, but the Python SDK (`pip install tsfile`) implements only `UNCOMPRESSED`, `SNAPPY`, `GZIP` and `LZ4`; opening this file with it yields no rows.
Read a converted file with the Apache TsFile Java SDK (`org.apache.tsfile:tsfile`):
```java
import org.apache.tsfile.file.metadata.IDeviceID;
import org.apache.tsfile.read.TsFileReader;
import org.apache.tsfile.read.TsFileSequenceReader;
import org.apache.tsfile.read.common.Path;
import org.apache.tsfile.read.expression.QueryExpression;
import org.apache.tsfile.read.query.dataset.QueryDataSet;
import org.apache.tsfile.write.schema.MeasurementSchema;
import java.util.ArrayList;
import java.util.List;
String path = "compressor_operations.tsfile";
try (TsFileSequenceReader sequenceReader = new TsFileSequenceReader(path);
TsFileReader reader = new TsFileReader(sequenceReader)) {
// Devices are enumerated as IDeviceID objects. Tables with TAG columns
// have multi-segment device ids that cannot be rebuilt from their string
// form, so always use getAllDevices() rather than getAllDeviceIds().
for (IDeviceID device : sequenceReader.getAllDevices()) {
List<Path> paths = new ArrayList<>();
for (MeasurementSchema schema : reader.getMeasurement(device)) {
String name = schema.getMeasurementName();
if (name != null && !name.isEmpty() && !name.equalsIgnoreCase("Time")) {
paths.add(new Path(device, name, true));
}
}
QueryDataSet dataSet = reader.query(QueryExpression.create(paths, null));
while (dataSet.hasNext()) {
System.out.println(dataSet.next());
}
}
}
```
## Source & license
- Original dataset: [`xpertsystems/oil024-sample`](https://huggingface.co/datasets/xpertsystems/oil024-sample)
- Source card title: OIL-024 — Synthetic Pipeline Flow Dataset (Sample)
- License: cc-by-nc-4.0 (as declared by the original dataset).
|