BubbleID-Flow / data_dictionary.json
hanhuark's picture
Add files using upload-large-folder tool
43c1d1a verified
Raw History Blame Contribute Delete
34.6 kB
{
"title": "BubbleID-Flow Multimodal Flow-Boiling Dataset Data Dictionary",
"schema_version": "1.0.0",
"global_missing_value_rule": "No dataset-wide numeric sentinel is defined. Blank spreadsheet cells and absent optional JSON keys are missing values.",
"schemas": [
{
"file_class": "annotation_image",
"paths": [
"AnnotatedImages/*.bmp"
],
"format": "BMP grayscale image",
"shape": "1024 x 1024 pixels",
"fields": []
},
{
"file_class": "labelme_annotation",
"paths": [
"AnnotatedImages/*.json"
],
"format": "LabelMe JSON",
"fields": [
{
"name": "version",
"dtype": "string",
"unit": "not applicable",
"definition": "LabelMe file-format version."
},
{
"name": "flags",
"dtype": "object",
"unit": "not applicable",
"definition": "Optional LabelMe image-level flags."
},
{
"name": "shapes[].label",
"dtype": "string",
"unit": "not applicable",
"definition": "Manual region label: bubble or bubble_cluster."
},
{
"name": "shapes[].points",
"dtype": "array[vertex,2]",
"unit": "pixel",
"definition": "Polygon vertices in source-image pixel coordinates."
},
{
"name": "shapes[].shape_type",
"dtype": "string",
"unit": "not applicable",
"definition": "LabelMe geometry type."
},
{
"name": "imagePath",
"dtype": "string",
"unit": "not applicable",
"definition": "Paired source BMP filename."
},
{
"name": "imageHeight",
"dtype": "integer",
"unit": "pixel",
"definition": "Source-image height."
},
{
"name": "imageWidth",
"dtype": "integer",
"unit": "pixel",
"definition": "Source-image width."
}
]
},
{
"file_class": "raw_optical_image",
"paths": [
"MultimodalData/Images/<case>/<state>/*.bmp"
],
"format": "BMP grayscale image",
"shape": "1024 x 1024 pixels",
"fields": []
},
{
"file_class": "camera_metadata",
"paths": [
"MultimodalData/Images/<case>/<state>/*.cihx"
],
"format": "camera metadata XML",
"fields": [],
"missing_value_rule": "Use camera-vendor metadata fields as supplied; no normalized schema is released."
},
{
"file_class": "thermal_reduced_workbook",
"example_path": "MultimodalData/FlowLoopThermalData/10gs_22C/10gs_22C.xlsx",
"shape": "variable rows x 47 columns",
"missing_value_rule": "Blank Excel cells represent missing source values; no numeric sentinel is documented.",
"fields": [
{
"name": "Time [h,m,s]",
"dtype": "numeric unless source cell is blank",
"unit": "h,m,s",
"definition": "Source time field; its absolute origin is not documented."
},
{
"name": "Time [s]",
"dtype": "numeric unless source cell is blank",
"unit": "s",
"definition": "Source time field; its absolute origin is not documented."
},
{
"name": "Mass Flow Rate [kg/s]",
"dtype": "numeric unless source cell is blank",
"unit": "kg/s",
"definition": "Measured or source-reduced mass-flow field."
},
{
"name": "Fluid Velocity [m/s]",
"dtype": "numeric unless source cell is blank",
"unit": "m/s",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Power [W]",
"dtype": "numeric unless source cell is blank",
"unit": "W",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Total Heat Flux [W/cm\u00b2]",
"dtype": "numeric unless source cell is blank",
"unit": "W/cm\u00b2",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Inlet Subcooling [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Inlet Pressure [kPa]",
"dtype": "numeric unless source cell is blank",
"unit": "kPa",
"definition": "Measured or source-reduced pressure field."
},
{
"name": "Outlet Pressure [kPa]",
"dtype": "numeric unless source cell is blank",
"unit": "kPa",
"definition": "Measured or source-reduced pressure field."
},
{
"name": "Inlet Temperature [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Outlet Temperature [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Saturation Temperature Inlet [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Saturation Temperature Outlet [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Location Inlet [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x1 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x2 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x3 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x4 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x5 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x6 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location x7 [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Location Outlet [m]",
"dtype": "numeric unless source cell is blank",
"unit": "m",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Temperature at Inlet [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x1 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x2 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x3 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x4 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x5 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x6 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x7 [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at Outlet [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Quality at Inlet",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x1",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x2",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x3",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x4",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x5",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x6",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at x7",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Quality at Outlet",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Heat Transfer Coefficient at x1 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x2 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x3 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x4 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x5 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x6 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x7 [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
}
]
},
{
"file_class": "thermal_input_workbook",
"example_path": "MultimodalData/FlowLoopThermalData/10gs_22C/10gs_22C_IN_with_units.xlsx",
"shape": "variable rows x 43 columns",
"missing_value_rule": "Blank Excel cells represent missing source values; no numeric sentinel is documented.",
"fields": [
{
"name": "Time [h,m,s]",
"dtype": "numeric unless source cell is blank",
"unit": "h,m,s",
"definition": "Source time field; its absolute origin is not documented."
},
{
"name": "Time [s]",
"dtype": "numeric unless source cell is blank",
"unit": "s",
"definition": "Source time field; its absolute origin is not documented."
},
{
"name": "Mass Flow Rate (M) [g/s]",
"dtype": "numeric unless source cell is blank",
"unit": "g/s",
"definition": "Measured or source-reduced mass-flow field."
},
{
"name": "Fluid Velocity (Vs) [m/s]",
"dtype": "numeric unless source cell is blank",
"unit": "m/s",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Inlet Temperature (Tin) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Outlet Temperature (Tout) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Inlet Pressure (Pin) [Pa]",
"dtype": "numeric unless source cell is blank",
"unit": "Pa",
"definition": "Measured or source-reduced pressure field."
},
{
"name": "Outlet Pressure (Pout) [Pa]",
"dtype": "numeric unless source cell is blank",
"unit": "Pa",
"definition": "Measured or source-reduced pressure field."
},
{
"name": "Voltage (V) [V]",
"dtype": "numeric unless source cell is blank",
"unit": "V",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Power (P) [W]",
"dtype": "numeric unless source cell is blank",
"unit": "W",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Temperature at x1 (T1) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x2 (T2) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x3 (T3) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x4 (T4) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x5 (T5) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x6 (T6) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature at x7 (T7) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Average Temperature (Ta) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Temperature Difference (dT) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Saturation Temperature Inlet (Tsat_in) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Subcooling Inlet (Tsub_in) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Saturation Temperature Outlet (Tsat_out) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Subcooling Outlet (Tsub_out) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Inlet Vapor Quality (xin)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x1 (xf1)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x2 (xf2)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x3 (xf3)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x4 (xf4)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x5 (xf5)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x6 (xf6)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Vapor Quality at x7 (xf7)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Outlet Vapor Quality (xout)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced vapor-quality field; its reconstruction assumptions are not documented in this release."
},
{
"name": "Heat Transfer Coefficient at x1 (h1) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x2 (h2) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x3 (h3) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x4 (h4) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x5 (h5) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x6 (h6) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Transfer Coefficient at x7 (h7) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Total Heat Flux (Qm) [W/m\u00b2]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Temperature Difference (dTw) [\u00b0C]",
"dtype": "numeric unless source cell is blank",
"unit": "\u00b0C",
"definition": "Measured or source-reduced temperature-related field."
},
{
"name": "Heat Flux (Q) [W/m\u00b2]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Average Heat Transfer Coefficient (havg) [W/m\u00b2\u00b7K]",
"dtype": "numeric unless source cell is blank",
"unit": "W/m\u00b2\u00b7K",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
}
]
},
{
"file_class": "thermal_auxiliary_workbook",
"example_path": "MultimodalData/FlowLoopThermalData/10gs_22C/10gs_22C_u_with_units.xlsx",
"shape": "variable rows x 14 columns",
"missing_value_rule": "Blank Excel cells represent missing source values; no numeric sentinel is documented.",
"fields": [
{
"name": "Time [h,m,s]",
"dtype": "numeric unless source cell is blank",
"unit": "h,m,s",
"definition": "Source time field; its absolute origin is not documented."
},
{
"name": "Time [s]",
"dtype": "numeric unless source cell is blank",
"unit": "s",
"definition": "Source time field; its absolute origin is not documented."
},
{
"name": "Mass Flow Rate (M) [g/s]",
"dtype": "numeric unless source cell is blank",
"unit": "g/s",
"definition": "Measured or source-reduced mass-flow field."
},
{
"name": "Power (P) [W]",
"dtype": "numeric unless source cell is blank",
"unit": "W",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Calculated Heat Rate (Qsp) [W]",
"dtype": "numeric unless source cell is blank",
"unit": "W",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Heat Rate Difference (dq) [W]",
"dtype": "numeric unless source cell is blank",
"unit": "W",
"definition": "Source-reduced thermal performance field; calibration and heat-loss evidence are not included."
},
{
"name": "Percentage Difference (qq) [%]",
"dtype": "numeric unless source cell is blank",
"unit": "%",
"definition": "Source workbook field; see the original header for its source label."
},
{
"name": "Experimental Friction Factor (fexp)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
},
{
"name": "Friction Factor (f)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
},
{
"name": "Friction Factor (Troniewski-Ulbrich, ftu)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
},
{
"name": "Friction Factor (Sadatomi, fs)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
},
{
"name": "Friction Factor (Kakac-Yener, fk)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
},
{
"name": "Friction Factor (Bhatti-Shah, fbs)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
},
{
"name": "Friction Factor (Kandlikar, fka)",
"dtype": "numeric unless source cell is blank",
"unit": "dimensionless or not stated",
"definition": "Source-reduced friction-factor field; not used as a validated manuscript endpoint."
}
]
},
{
"file_class": "ae_text_record",
"paths": [
"MultimodalData/AcousticDatta/<case>/HIT_*.TXT",
"MultimodalData/AcousticDatta/<case>/TIME_*.TXT"
],
"format": "EasyAE fixed-width text export",
"shape": "variable rows x vendor-defined fields",
"missing_value_rule": "No numeric sentinel is documented by the export.",
"fields": [
{
"name": "ID",
"dtype": "integer",
"unit": "not applicable",
"definition": "EasyAE record identifier."
},
{
"name": "SSSSSSSS.mmmuuun",
"dtype": "float",
"unit": "s",
"definition": "EasyAE source time field; absolute origin is not documented."
},
{
"name": "PARA1, PARA2",
"dtype": "float",
"unit": "vendor-defined",
"definition": "EasyAE source fields; units are not documented in this release."
},
{
"name": "CH",
"dtype": "integer",
"unit": "channel",
"definition": "EasyAE acquisition channel identifier."
},
{
"name": "RISE, COUN, ENER, DURATION, A-FRQ, RMS, PCNTS, THR, R-FRQ, I-FRQ, SIG STRNGTH, ABS-ENERGY, FRQ-C, P-FRQ, AMP, ASL",
"dtype": "numeric",
"unit": "vendor-defined",
"definition": "EasyAE event or continuous-summary fields retained with the vendor labels; calibration and unit definitions are not included."
}
]
},
{
"file_class": "raw_ae_waveform",
"paths": [
"MultimodalData/AcousticDatta/<case>/Raw Data/*.wfs"
],
"format": "EasyAE waveform binary",
"shape": "vendor-defined binary waveform sequence",
"fields": [],
"missing_value_rule": "Not applicable; decode with a compatible WFS decoder."
},
{
"file_class": "ae_acquisition_export",
"paths": [
"MultimodalData/AcousticDatta/<case>/Raw Data/*.DTA"
],
"format": "EasyAE text acquisition export",
"shape": "variable rows x vendor-defined fields",
"fields": []
},
{
"file_class": "model_checkpoint",
"paths": [
"ModelWeights/model_final.pth"
],
"format": "PyTorch checkpoint",
"shape": "model parameter tensors",
"fields": []
},
{
"file_class": "derived_presentation_video",
"paths": [
"Videos/*.mp4"
],
"format": "MP4 presentation video",
"shape": "1920 x 720 pixels, 5 frames/s, 80 frames for the included 45 V videos",
"fields": [],
"missing_value_rule": "Not applicable; the videos are derived visual summaries, not native-time records."
}
]
}