Keep denoise README focused on datasets and repository ownership
Browse files- denoise/README.md +16 -38
denoise/README.md
CHANGED
|
@@ -1,43 +1,21 @@
|
|
| 1 |
-
#
|
| 2 |
|
| 3 |
-
**
|
| 4 |
-
|
|
|
|
|
|
|
|
|
|
| 5 |
|
| 6 |
-
|
| 7 |
-
| --- | --- | ---: |
|
| 8 |
-
| [01_tv.ipynb](01_tv.ipynb) | Download, inspect, calibrate, TV1, compare and save | **35–36 s** for TV; about 42 s across cells before download |
|
| 9 |
-
| [02_shine.ipynb](02_shine.ipynb) | Same workflow with one self-supervised neural model | **4½–9 min** (271–523 s observed), 64 epochs × 128 steps |
|
| 10 |
-
| [03_generate_abtem.ipynb](03_generate_abtem.ipynb) | Optional regeneration of the specimen | **12 s** across code cells |
|
| 11 |
|
| 12 |
-
|
| 13 |
-
|
| 14 |
-
|
| 15 |
-
|
| 16 |
|
| 17 |
-
|
| 18 |
-
|
| 19 |
-
|
| 20 |
-
notebooks do not require abTEM.
|
| 21 |
|
| 22 |
-
|
| 23 |
-
|
| 24 |
-
version containing it has not been verified. Tested installed versions:
|
| 25 |
-
QuantEM.GPU 0.0.1rc15 and QuantEM.Widget 0.0.1rc41. Select an available CUDA
|
| 26 |
-
GPU before starting Jupyter, for example `CUDA_VISIBLE_DEVICES=0 jupyter lab`.
|
| 27 |
-
Run the notebook from top to bottom.
|
| 28 |
-
|
| 29 |
-
The [shared input](simulated_au_nanobeam_pg_dose1/) is only the **noiseless
|
| 30 |
-
abTEM expectation plus geometry and a noise recipe**, about 120 MiB.
|
| 31 |
-
The notebook creates noisy science observations, independent dark/flat
|
| 32 |
-
exposures and `.pt` calibration artifacts locally. QuantEM.GPU loads/saves
|
| 33 |
-
the data; Show4DSTEM displays native patterns and allows scan-region inspection.
|
| 34 |
-
|
| 35 |
-
**Quality status is explicit.** TV improves RMSE but fails the central residual
|
| 36 |
-
gate. SHINE worsens RMSE on this example and remains experimental. Both
|
| 37 |
-
currently return `no_feasible_candidate`; neither is certified to add zero
|
| 38 |
-
false peaks. Read the regional audit before treating an image as quantitative.
|
| 39 |
-
|
| 40 |
-
The Poisson–Gaussian recipe is an assumed synthetic detector, not validated
|
| 41 |
-
ARINA electronics or a new experimental result. Experimental inspiration:
|
| 42 |
-
**Serin Lee and Andrew Barnum**, [Au liquid-cell data](https://doi.org/10.5281/zenodo.18167694).
|
| 43 |
-
No experimental observations are shared here.
|
|
|
|
| 1 |
+
# Denova denoising datasets
|
| 2 |
|
| 3 |
+
**Hugging Face is for data and its descriptive metadata only.** Scientific
|
| 4 |
+
code, TV/SHINE tutorial notebooks, helper modules, result comparisons and
|
| 5 |
+
research reports belong in the [denoise repository](https://github.com/bobleesj/denoise).
|
| 6 |
+
Use the matching development checkout for the calibrated 4D-STEM workflow;
|
| 7 |
+
a released package containing that workflow has not been qualified.
|
| 8 |
|
| 9 |
+
## Available input
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
| 11 |
+
[simulated_au_nanobeam_pg_dose1](simulated_au_nanobeam_pg_dose1/) contains one
|
| 12 |
+
losslessly compressed synthetic Au nanobeam expectation, geometry, numeric
|
| 13 |
+
noise-generation parameters, provenance and checksums. It is approximately
|
| 14 |
+
120 MiB, shaped 32×32 scan positions × 192×192 detector pixels.
|
| 15 |
|
| 16 |
+
Generate noisy observations, calibration exposures and `.pt` artifacts locally
|
| 17 |
+
using the code in the software repository. No experimental ARINA observations
|
| 18 |
+
or independently measured hardware calibration are included.
|
|
|
|
| 19 |
|
| 20 |
+
Experimental inspiration and data credit: **Serin Lee and Andrew Barnum**,
|
| 21 |
+
[Au liquid-cell dataset](https://doi.org/10.5281/zenodo.18167694), CC BY 4.0.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|