content
stringlengths
500
1.99k
filename
stringclasses
5 values
Q
stringlengths
0
342
In assessing the THORs biofidelity, it is within the narrow scope of these seat accelerations and pulse axes. This investigation was not a systematic assessment of THOR across a range of conditions. While the THOR in part has been designed to optimally reproduce human responses to frontal impacts, it was anticipated th...
2013 Stapp papers(1)_content_list_text.csv
How does the limited scope of seat accelerations and pulse axes in the current study affect the ability to comprehensively assess the THOR dummy's biofidelity in simulating human spinal injury responses during frontal impacts?
CORA was used as a principal tool for comparing the THOR response to humans in this investigation. CORA is a useful tool for analyzing time series data as it compares entire response trajectories rather than just single peaks or zero-crossings. The objective rating of two curves (or families of curves) is based on two ...
2013 Stapp papers(1)_content_list_text.csv
How can the subjective weighting of sub-components in the CORA analysis impact the assessment of biomechanical responses in injury studies using the THOR anthropomorphic test device?
CORA scores are bounded between 0 and 1, and subweightings must add to 1. The overall score will depend on the combination of weights and the period of analysis. Generally, a very low CORA score would have very low values across all of the rating dimensions, and a very high CORA score likely rates well across all dimen...
2013 Stapp papers(1)_content_list_text.csv
How might different weight assignments within the CORA scoring system affect the interpretation of biomechanics data in assessing injury risks during a frontal impact?
For fontal impacts, the THOR matches the human peak head acceleration in the mathbfX -axis reasonably well. The initial acceleration response of the THOR lags that of humans by about 30 to 40mathrmms (Figure 7) while the peak acceleration response lags the human peak response by 20-30ms. By the recovery phase of the re...
2013 Stapp papers(1)_content_list_text.csv
How does the lag in initial acceleration response of the THOR dummy during frontal impacts affect its accuracy in predicting potential head injuries in lighter versus heavier individuals?
For the chest acceleration in the x-axis, the THOR exhibits greater peak accelerations than humans. The trajectory of the response is in phase with the human response. In the human trials, subjects were instructed to brace their hands against their lap and their feet against the seatsled to minimize the effects of the ...
2013 Stapp papers(1)_content_list_text.csv
How do the biomechanical differences in chest acceleration and bracing strategies between human subjects and the THOR dummy impact the assessment of injury risk in crash simulations?
For -mathbfZ -axis seat accelerations, the THOR head acceleration response in the z-axis attains higherpeak accelerations than humans. The phase of the peak acceleration depends upon the rise time of the seat acceleration. Faster rise times mathrm40ms) result in a lagging THOR response of about 5 to 10mathrmms ,70mathr...
2013 Stapp papers(1)_content_list_text.csv
How do differences in peak head acceleration and rotational displacement between the THOR dummy and human subjects during -Z-axis seat accelerations impact the accuracy of injury prediction for real-world scenarios?
Generally the THOR chest acceleration tends to slightly lead the human chest acceleration by a few milliseconds. The peak acceleration for the THOR chest in the z-axis is also larger than most human responses. The acceleration difference is likely due to the dynamic response of the thoraciclumbar spine elements of the ...
2013 Stapp papers(1)_content_list_text.csv
How do the structural differences in the thoracolumbar spine and shoulder connections between the THOR anthropomorphic test device and humans impact the assessment of injury risk, particularly in terms of chest and shoulder acceleration responses?
For spinal impacts, the seat pan force is another measure that can be compared between the THOR and humans. Some of the highest CORA scores overall were seen in the seat pan force, meaning that the THOR response is well matched to the human response. Performance was better for lighter subjects at lower peak acceleratio...
2013 Stapp papers(1)_content_list_text.csv
How do the material properties and energy attenuation characteristics of the THOR dummy's flesh impact its ability to accurately replicate human spinal impact responses during biomechanical testing, especially at varying peak acceleration levels?
Interestingly, one subject that was tested under multiple conditions matched quite well with the THOR in all measured parameters (accelerations, but especially kinematics). This male subject (J-5) weighed 225 pounds at the time of testing, and was the heaviest subject tested in the spinal acceleration battery. However,...
2013 Stapp papers(1)_content_list_text.csv
How does the variation in body weight and seated height, as seen in subject J-5, influence the accuracy of injury prediction models like THOR in assessing spinal accelerations and potential injury risks?
The THORs ability to replicate human volunteer responses to frontal and spinal impacts is highly variable. Depending on the application, the THOR may match quite well or very poorly. For example, if one is interested in z-axis chest accelerations to spinal impacts the THOR response is quite well matched to heavier subj...
2013 Stapp papers(1)_content_list_text.csv
How can the variability in THOR's ability to replicate human responses to different frontal and spinal impact scenarios, particularly across varying body sizes and impact forces, affect the accuracy of injury assessments for space flight conditions?
Given that future planned space capsule returns to Earth will include a significant spinal impact component, NASA is very interested in understanding the THOR response in this axis. Currently the nominal impulse for MPCV looks to be a combined x- z-axis impact. Despite the variability in THOR response, our continual u...
2013 Stapp papers(1)_content_list_text.csv
How might the biomechanical response of the THOR anthropomorphic test device (ATD) to combined x- z-axis impacts inform NASA's strategies for the assessment and mitigation of spinal injuries during space capsule landings?
Several limitations were evident in this assessment of the THOR. One that may have impacted our results is that the seat and restraints were not the same across all of the human volunteer studies. The spinal impact studies occurred in 1989, and the frontal impact data set was taken from one study in 1995 and another in...
2013 Stapp papers(1)_content_list_text.csv
How do differences in seat pan mass and setup configurations in biomechanical testing influence the accuracy of injury assessment and comparisons across different studies?
For sled impulses, every attempt was made to match the THOR impact profiles to those of these previous studies, but as the CORA scores reflect, some pulses were better matched than others. In general, the peak acceleration and rise times matched quite well, but there was some difficulty associated with matching the lon...
2013 Stapp papers(1)_content_list_text.csv
How do the differences in measurement locations, such as the center of gravity of the head versus a bite bar and T6 versus a sternal accelerometer, affect the accuracy and reliability of biomechanical data in assessing injury risk and severity during sled impact tests?
Finally, the THOR itself had some limitations. We tested the only THOR available, which is a 50th percentile male representative. When comparing this THORs responses to a human volunteer population containing such a wide range of anthropometrics, it is not surprising to find significant comparison variability. The othe...
2013 Stapp papers(1)_content_list_text.csv
How might the lack of active bracing capabilities in the THOR 50th percentile male crash test dummy affect the accuracy of injury predictions in real-world scenarios, and what potential improvements could be made to enhance its biofidelity in these situations?
Future plans include determining whether the THOR responds closer to humans than the Hybrid III does for the dependent measures assessed in the current investigation. To accomplish this, a Hybrid III will be tested in matched conditions to the THOR, and CORA scores will then be determined for the HybridIII versus human...
2013 Stapp papers(1)_content_list_text.csv
How can dimensional scaling techniques be effectively utilized to improve the accuracy of comparing THOR and Hybrid III dummy responses to human injury responses in biomechanical assessments?
In addition, work is planned to assess the THOR in lateral impact conditions. Because of the unique landing profiles, multi-directional responses are likely, so an ATD that can respond in all three axes is highly desirable. Although the THOR is not designed for this use, Rangarajan et al demonstrated that simple modifi...
2013 Stapp papers(1)_content_list_text.csv
What biomechanical modifications could be considered to improve the THOR dummy’s response to multi-directional impacts, and how might these adjustments enhance its effectiveness in injury assessment during lateral impact simulations?
The results of this assessment show that the THOR response to frontal and spinal impacts has a wide variability compared with human responses. Chest responses tend to be a closer match to humans than head responses. Seat pan forces are quite well matched, especially for certain human subject types. The active bracing o...
2013 Stapp papers(1)_content_list_text.csv
How can the differences in active bracing between human subjects and the THOR anthropomorphic test device impact the accuracy of injury predictions in frontal and spinal impacts during biomechanics assessments?
Papers must be written in an objective, scholarly, and scientific manner, and must be free of commercialism, advertisement, and product identification. All papers must be written according to conventional English usage. Authors whose first language is not English should have their manuscript edited before submission an...
2013 Stapp papers(1)_content_list_text.csv
How do standardized guidelines and adherence to objective scientific writing impact the reliability and reproducibility of injury biomechanics research findings?
The scope of material contained in this journal includes new data on the biomechanics of injury and human tolerance, new methods and tools to study the biomechanics of injury, new developments in occupant protection systems, and new concepts on the biomechanics of injury based on experimental and analytical studies. Pa...
2014_58th_Stapp_final(1)_content_list_text.csv
How might the latest developments in occupant protection systems influence the thresholds of human tolerance to impact forces as reported in recent studies on injury biomechanics?
As one of todays leading researchers and scientists in the field of injury biomechanics, John had an unwavering dedication and enthusiasm to translate his unmatched knowledge and understanding of injury mechanisms and causation scenarios into practical and effective countermeasures that have saved unknown numbers of li...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the principles of injury biomechanics and the understanding of injury mechanisms be applied to develop more effective safety features in passenger and racecar vehicles to prevent serious injuries during crashes?
ABSTRACT The existence of devices to protect ones head from impact injury certainly predated any understanding we may have about the biomechanics of head injury. From the pioneering work of our own John Paul Stapp, of Gurdjian, and of Holbourne to the complex finite element models of today, incredible progress has bee...
2014_58th_Stapp_final(1)_content_list_text.csv
How can current finite element models of head protection be improved to more accurately assess and mitigate the risk of rotationally-induced brain injuries in modern helmet designs?
The development of protective headgear has been governed largely by test standards that have been adopted to quantify helmet performance requirements. To a great extent these standards are designed and promulgated by people with the absolute best of intentions. Yet the mechanical, and especially the biomechanical, base...
2014_58th_Stapp_final(1)_content_list_text.csv
How have biomechanical limitations in current test standards affected the ability to develop more advanced protective headgear for injury prevention, and what specific advancements in biomechanical understanding are needed to overcome these hurdles?
Multi-parameter impact dose thresholds cannot be developed until an accurate and precise single event dosimeter is created. Unfortunately, there is no accurate and precise single event dosimeter available. Lacking a single event dosimeter, frontline caregivers continue to rely on subjective identification of at-risk at...
2014_58th_Stapp_final(1)_content_list_text.csv
How might advances in biomechanical engineering contribute to the development of an accurate and precise single event dosimeter for better identification and assessment of concussive and subconcussive events in athletes?
where r_p is a vector of constant length from point O to point P, a_O is linear acceleration of a point O on the body, angular velocity is boldsymbolomega , and angular acceleration is boldsymbolomega . For a typical in vitro collision, acceleration increases from zero to peak in 5 to 10 milliseconds defined as Region...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the accurate evaluation of translational and tangential accelerations in Region 1 impact the assessment and prediction of injury during a typical in vitro collision?
Friction between the mouthguard and smooth aluminum dentition provided sensor-skull coupling force. We did not physically (finger pressure), visually (high-speed film) or temporally (comparing mouthguard and Reference data) observe significant mouthguard-dentition de-coupling, displacement or transient deformation in a...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the coupling force provided by the friction between the mouthguard and aluminum dentition impact the accuracy and reliability of biomechanical measurements during high-impact tests, particularly in assessing the risk of head and dental injuries?
For XYZ component linear regression calculations taken at time of peak, we desired slope and mathbfR2 near 1.00 with y-offset near zero. We also calculated accuracy and precision at the time of peak for XYZ component linear CG and angular acceleration. Finally, we calculated average temporal accuracy and precision in R...
2014_58th_Stapp_final(1)_content_list_text.csv
How do variations in the slope and R² values of XYZ component linear regression calculations at the time of peak influence the assessment and prediction of injury risk in biomechanical studies?
We made a custom Intelligent Mouthguard for each athletes dentition. During pressure forming the mouthguard material followed each athletes teeth and embrasure space contours. This ensured coupling to overhanging geometrical irregularities; custom forming is preferable to boil-and-bite forming because boil-and-bite for...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the significant mouthguard-dentition geometrical coupling force achieved through custom intelligent mouthguards compare to traditional boil-and-bite mouthguards in minimizing the risk of orofacial injuries during high-impact sports?
In dynamic rotation tests, our gyroscope correction data fit the linear model well. The gyroscope angular acceleration correction does not provide perfect temporal matching compared to Reference. This manifests itself in angular velocity mismatch between corrected Intelligent Mouthguard and Reference angular velocity. ...
2014_58th_Stapp_final(1)_content_list_text.csv
What are the implications of angular velocity mismatches in gyroscope data on injury assessment in regions where centripetal acceleration plays a negligible role?
With increasing frequency of harmonic content of a signal, we find increasing imprecision in calculated CG linear acceleration. Therefore, there is a practical limit to applicability of our 3mathrma3mathrmomega hardware platform due to gyroscope bandwidth limitations. We define this limit as less than 100mathrmHz in th...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the limitation of gyroscope bandwidth in the measurement platform impact the precision of angular and linear acceleration data, and what implications might this have for accurately assessing head injuries in contact sports like American football and boxing?
Our results are based on Intelligent Mouthguard comparison to Reference Hybrid III headform to determine whether Intelligent Mouthguard qualifies as a single event dosimeter within our tested ranges and configurations. These ranges are: American football and Boxing, first harmonic frequency less than 100mathrmHz , XYZ ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the comparison between Intelligent Mouthguard data and the Reference Hybrid III headform contribute to understanding the accuracy and reliability of the mouthguard as a biomechanical sensor for assessing head impacts in sports such as American football and boxing?
The Institute of Medicine recently recommended that research on age- and sex-related biomechanical determinants of injury risk for concussion in youth are critical for informing the development of rules of play, effective protective equipment and equipment safety standards, impact-monitoring systems, and athletic and m...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the development of a single event head impact dosimeter, which accounts for age- and sex-related biomechanical determinants and impact direction, contribute to more accurate injury risk assessments for concussions in youth sports?
We did not test the Intelligent Mouthguard components or system under every conceivable configuration. If in vitro or in vivo data are acquired in the future that reside outside the boundaries of validated range of harmonic content or sensor-skull coupling we studied, further validation may be needed to quantify data a...
2014_58th_Stapp_final(1)_content_list_text.csv
How can varying skull resonant frequencies between individuals impact the accuracy of biomechanical measurements in higher frequency impacts and influence injury assessment outcomes?
We also did not quantify mouthguard-dentition coupling force. Dentition geometry provides mouthguard coupling friction. All in vitro tests were performed on a smooth aluminum dentition with vertical sides, without lower jaw clamping. We have no data-based evidence of de-coupling in vitro. In vivo, our human subjects lu...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the variation in mouthguard-dentition coupling force, influenced by factors like saliva lubrication and dentition geometry, affect the biomechanical assessment of potential oral injuries during collisions in sports?
Our current results focus on accurately and precisely calculating peak acceleration and time traces for any point on the head during and immediately after impact in vitro. In the future we will expand these calculations to live athletes when single head impact event uncertainties in vivo must also be quantified. As par...
2014_58th_Stapp_final(1)_content_list_text.csv
What are the potential challenges and benefits of using subject-specific head kinematics, as derived from intelligent mouthguard sensors and MRI, in assessing head injuries in athletes during live events?
Effectiveness of our reconstruction method to a large degree depends on the appropriate selection of Omegafrac2piT. , where T is the time period when acceleration increases from zero to maximum value and goes back to zero (or angular velocity increases from zero to its maximum value). We made this process algorithmic a...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the selection of Omegafrac2piT and the implementation of yT_fit minimization in the reconstruction algorithm influence the accuracy of injury biomechanics models, particularly in the assessment of acceleration phases during an impact event?
Scanning output data contained point clouds of scanned object image in the Scanner Coordinate System. By selecting points of interest, we obtained sensor surface points, attachment point, and mathrmX_a ,mathrmY_mathrma, Z_mathrma vectors coordinates in the scanner coordinate system. We converted scanner coordinate syst...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the conversion of scanner coordinate system data to the J211 standard using vector translation impact the precision of biomechanical injury assessments?
Intelligent Mouthguard measures three linear accelerations and three orthogonal angular velocities. Sensitive axes are located at known points and orientations. We calculated headform CG rigid body kinematics as a function of time based on sensor measurements. Figure A4-1 depicts such a free rigid body moving in a glob...
2014_58th_Stapp_final(1)_content_list_text.csv
What potential injury mechanisms could be assessed by analyzing the rigid body kinematics of the headform, as calculated through the data from the Intelligent Mouthguard's accelerometers and gyroscopes?
Acceleration of point mathbfP is a sum of translational acceleration pmb R , centripetal acceleration pmbomegatimestextbfemomegatimestextbfemr ,and tangential acceleration omegatimes r . For an Intelligent Mouthguard based measurement scheme, not all variables on the right side of equation (A4-3) are known. Vector pmbo...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the limitations of the Intelligent Mouthguard, such as not directly measuring the translational acceleration \(\mathbf{R}\), impact the accuracy of injury assessments in sports-related concussion studies?
Equation (A4-3) contains unknown point scriptstyleobullet acceleration pmbR . By placing point P in the accelerometer locations and applying equation (A4-3) components of vector pmb R can be found as a solution of a system of three linear equations with three unknowns for each moment in time. The important condition fo...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the geometric arrangement of accelerometer axes, particularly orthogonal configurations, impact the accuracy of injury biomechanics assessments, especially when estimating accelerations at different points on a moving body?
The axis of rotation would be determined through measured vector pmbu_omega . Mass moment of inertia I_m around an arbitrary axis, defined by vector pmbu_omega , is ill defined. A table of I_m values for variety of axes going through head CG would have to be created. The effect of brain being a contained fluid, not a r...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the inclusion of the brain's fluid properties, as opposed to treating it as a rigid mass, influence the accuracy of injury assessments in terms of mass moment of inertia calculations during head impacts?
This method is valid for the situation when the head is experiencing rigid body acceleration due to a blow. It indicates location of the force of the blow on the head. For a helmet protected head, a line going from head CG to the predicted impact location point on the head may not go through actual contact area on a he...
2014_58th_Stapp_final(1)_content_list_text.csv
How do errors in the measurement of parameters like pmba_c g and pmbomega impact the accuracy of predicting impact direction and location in biomechanical analyses, particularly for smaller acceleration values in head injury scenarios?
(1) Separate test-specific time traces into frequency bins. (2) Divide the time traces of all XYZ components in a given test into Region 1, Region 2 and Region 3. (3) For a given test, and each time trace Region, use equation A6-2, but substitute all values in the time traces of Reference and Intelligent Mouthguard for...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the integration of frequency bin analysis and regional differentiation (Region 1, Region 2, and Region 3) of time traces improve the accuracy and reliability of detecting potential head injuries using linear CG and angular acceleration measurements from the Intelligent Mouthguard system?
ABSTRACT Finite element (FE) models are often used to study the biomechanical effects of traumatic brain injury (TBI). Measures based on mechanical responses, such as principal strain or invariants of the strain tensor, are used as a metric to predict the risk of injury. However, the reliability of inferences drawn fr...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the predictive accuracy of axonal strain as an indicator for traumatic brain injury (TBI) compare with other mechanical measures such as maximum principal strain (MPS), anisotropic equivalent strain (AESM), and cumulative strain damage measure (CSDM) in finite element models?
Logistic regression shows a statistical correlation between all the mechanical predictors and injury data for different regions of the brain. Peaks of axonal strain have the highest AUC and determine a strain threshold of 0.07 for corpus callosum and 0.15 for the brainstem, in agreement with previously experimentally d...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the strain threshold of 0.07 for the corpus callosum and 0.15 for the brainstem contribute to the understanding and prediction of reversible axonal injuries in different regions of the brain during impact in sports-related injuries?
In addition, observations by Tamura et al. (2007) suggest that the individual fiber in the white matter experiences smaller stretches than those applied to the bulk tissue, and that there is a close correlation between the alignment of nerve fibers and the neural fiber strain. Porcine brain specimens were subjected to ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the alignment of nerve fibers within the white matter influence their susceptibility to strain-related injuries, and what implications does this have for developing more accurate biomechanical models for predicting axonal injury risk?
The aimss of the curreent study are thus to evaluuate axonal strrain as a preddictor for mildd traumatic brrain injury, too compare it to previously proposed injjury metrics, and to establish locall axonal strrain thresholdds for injuriees. To this eend, a validaated anisotropic FE model oof the human head is used and ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the application of axonal strain as a predictor of mild traumatic brain injury compare to other injury metrics, such as maximum principal strain and cumulative strain damage, in terms of accuracy and reliability in predicting TBI from accident reconstructions?
All parametrical choices concerning the geometry of the head are based on a detailed analysis of previous studies (Kleiven, 2007) and the same constitutive laws as those used in the model proposed by Giordano et al. (2014) are used (Table 1). In fact, the enhanced model shows good correlation with experiments of skull-...
2014_58th_Stapp_final(1)_content_list_text.csv
How do the constitutive laws used in Giordano et al.'s model, which have shown good correlation with experiments of skull-brain relative motion, contribute to more accurate predictions of intracerebral acceleration and intra-cranial pressure in head injury biomechanics?
The bulk modulus K is lowered with respect to the acknowledged value of 2 mathrmGPa in account of stability reasons. Since K is still much larger than the shear modulus G, the brain exhibits nearly incompressible behavior and the same pressure and strain responses are calculated. Parameters G and k_1 are instead optima...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the variably optimized shear modulus G and fiber-reinforcement parameter k1 influence the mechanical response and potential for injury in different brain areas during traumatic brain injuries?
Before uutilization, thhe anisotropicc FE modell is validated against availaable post-morttem experimenntal data by HHardy et al. ((2001, 2007), for three imppact directionss (frontal, occipital, annd lateral). A comparisoon of the model predicctions with six experimennts of relativee brainskull mmotion and strrain is ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the incorporation of anisotropic material properties in the finite element (FE) model influence the accuracy of brain-skull motion and strain predictions during different impact directions, and what implications might this have for improving injury assessment?
In all the simulations, the original KTH head model constitutive laws are used (Table 1) with the exception of the brain, where the behavior is altered as previously reported. Fig.3, 4 and 5 illustrate the comparison between the simulated relative skull brain motion and the relative motion of the target for impacts C75...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the altered constitutive behavior of the brain in the simulations impact the accuracy of predictions related to skull and brain relative motion during impacts, and what implications does this have for injury assessment in biomechanics?
In order to evaluate the effects of the inclusion of the anisotropy, the response of the anisotropic model is also compared with the prediction of the original isotropic head where the brain is described by a second-order Ogden-based hyper-viscoelastic law (Kleiven 2007). The results of the simulations show that the an...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the introduction of anisotropy in the biomechanical modeling of the brain affect the accuracy of predicting localized brain tissue motion in comparison to the isotropic model when assessing potential traumatic brain injuries?
As it can be seen from Fig.3 - 6, predictions from the frontal, occipital and lateral impacts for anisotropic and isotropic model are similar; both the Ogdenbased isotropic law and the GOH anisotropic material model were assigned values to reproduce experimental data from Franceschini (2006); therefore, a similar behav...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the superior-inferior axis motion prediction by the anisotropic material model impact injury assessment in comparison to the isotropic model, and what implications could this have for the development of protective gear?
The FE head model is imposed on the kinematics based on reconstructions of 58 sport accidents from the American National Football League (NFL), which include 25 concussions and 33 injury-free cases (Newman et al. 2000). The kinematics of each accident was reconstructed with the aid of analyses of video recordings of th...
2014_58th_Stapp_final(1)_content_list_text.csv
How do the measured linear and angular accelerations from the dummy head impacts correlate with the occurrence and severity of concussions in the reconstructed NFL sport accidents?
Considering the anatomy and physiology of the human head components, the interface between the dura mater and the skull is modeled with tied-surface contacts in LS-DYNA ensuremathmathcalR . Since the presence of the cerebrospinal fluid between the meningeal membranes and the brain is not negligible for large rotational...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the modeling of sliding-only contact at the meninges-brain interface in LS-DYNA impact the biomechanical understanding of brain injury mechanisms during high rotational loads, and what implications does this have for accurately assessing injury risk?
where varepsilon_a x o n represents the axonal strain, checkI_1 corresponds to the first invariant of the isochoric Cauchy-Green strain tensor, ۱෨is the isochoric Cauchy-Green strain tensor, pmbn_0alpha the fiber unit vector in the undeformed configuration and mathrmk the dispersion parameter. This measure is directly ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the anisotropic formulation of the brain tissue's constitutive model influence the measurement and assessment of axonal strain in traumatic brain injuries?
Cumulative strain damage measure was proposed by Bandak et al. (1995) to evaluate the extent and severity of the strain-related damage within the brain. This mechanical measure is based on the hypothesis that the injury is associated with the cumulative volume of brain matter experiencing tensile strain above a critica...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the cumulative strain damage measure (CSDM 10) correlate with the severity and extent of brain injuries when the first principal logarithmic strain threshold is set to a critical level, and what implications might this have for improving diagnostic and protective strategies in traumatic brain injury cases?
The HIC is a measure of the likelihood of head injury arising from an impact and takes into account the effects of translational head acceleration and the duration thereof. HIC is currently used in automotive impact regulations, where an mathrmHIC_15 of 700 is pointed out to be the limit above which a person may suffer...
2014_58th_Stapp_final(1)_content_list_text.csv
How might the inclusion of rotational acceleration in addition to translational acceleration provide a more comprehensive assessment of traumatic brain injuries in automotive impact scenarios, and what implications could this have on current head injury criteria like HIC?
In previous years, Hardy et al. (2001 and 2007) pointed out the importance of angular speed in experiments describing the motion of brain with respect to the overall motion of the skull. It has also been reported that HIC manage to predict the strain level in the brain of a finite element (FE) model for purely translat...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the Brain Injury Criterion (BrIC) utilize angular velocity components to predict brain injury risk, and how might this differ in its effectiveness compared to using angular acceleration or other traditional injury criteria?
Logistic regression analysis is employed to compare binary injury data (concussion1 no concussion textsuperscript-0 )with continuous maximum principal strain (MPS), maximum axonal strain (MAS), cumulative strain damage (CSDM), anisotropic equivalent strain (AESM), brain injury criterion (BrIC) and head injury criterio...
2014_58th_Stapp_final(1)_content_list_text.csv
How can logistic regression models that incorporate variables like maximum principal strain (MPS) and cumulative strain damage (CSDM) improve the accuracy of predicting concussion risk in individuals exposed to head impacts?
In the present work, the statistics toolbox of MATLAB software is used to perform the analysis. As first, the Wald chi-square test is used to verify whether there are significant relationships between risks of concussion and the mechanical responses. A null hypothesis is established, which assumes that mechanical respo...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the Wald chi-square test contribute to understanding the relationship between mechanical response parameters and the risk of concussion in biomechanical injury assessment?
The ROC curve is a plot that illustrates the specificity and sensitivity of a binary classifier as its discrimination threshold is varied (Bewick et al. 2004). It is constructed by plotting the true positive rate (sensitivity) vs. the false positive rate (1- specificity), at various threshold settings. The performance ...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the area under the ROC curve (AUC) be utilized to effectively evaluate and compare the predictive capabilities of strain-based versus head kinematics-based measures in assessing the risk of injury in athletes?
For the concussed player, areas of large principal strain can be seen in the corpus callosum as well as in the left temporal and parietal lobe and right superior parts of the cortex (Fig. 10). Fig. 11 shows that axonal strain is significantly lower and more localized than principal strain; the concussed player presents...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the relative orientation between principal and axonal strains influence the degree of axonal strain and its potential impact on brain injury severity, particularly in the corpus callosum, left parietal lobe, and superior cortex areas?
Fig. 13 illustrates a summary of the predicted injury probability for concussion based on the FE model mechanical response for the 58mathrmNFL cases. The six injury predictors are evaluated and compared for the region of the brain where they show the highest predictive power. Logistic regression complete results can be...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the predictive power of different injury predictors for concussion vary across different brain regions, and what implications does this variation have for accurately assessing concussion risk using finite element models?
A statistical correlationn between maaximum principal strain, mmaximum axoonal strain, ccumulative strrain damage mmeasure and anisotropic equivalent strrain measure is found for these regions of the brain for each tisssue injury ppredictor. Acccording to the Hosmer-LLemeshow tesst, the maximmum axonal strrain in the c...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the maximum axonal strain compare to other tissue injury predictors in assessing traumatic brain injury in anisotropic regions such as the corpus callosum, and what implications does this have for improving injury models?
MMoreover, acccording to thhe Wald Chi--square test, AAESM has the highest corrrelation with injury data (WWT mathrmp,1.41mathrme-004) in thhe corpus calllosum. This inndicates that the anisotroopic predictoors (AESM, MMAS) are moore suitable ffor creating aa model for thhese data at thhe 95 or higgher confidennce leve...
2014_58th_Stapp_final(1)_content_list_text.csv
What biomechanical mechanisms might explain the high correlation between anisotropic predictors such as AESM and injury data in the corpus callosum, particularly in the context of mTBI?
Althoughh MAS in thee corpus calllosum shows the highest value of correlation with thee injury data, iit is MAS in the brainstemm that has thhe highest AAUC (Table 5)). With a straain threshold of 0.15, 93 of cases aree correctly classified (cooncussion no concussioon) and the proobability that an injured plaayer expe...
2014_58th_Stapp_final(1)_content_list_text.csv
How does maximal axonal strain (MAS) compare to other biomechanical metrics, such as maximum principal strain (MPS), in accurately predicting concussions, particularly in anisotropic regions of the brain like the corpus callosum and brainstem?
AAssuming the over-predictioon, this also eexplains the laarge principaal strain assoociated with concussion, wwhich is founnd in the pressent work andd in studies reported by Zhhang et al. (20004) and Kleiiven (2007). Inn those studiees, loading coonditions assoociated with cconcussion alsso resulted inn principal str...
2014_58th_Stapp_final(1)_content_list_text.csv
How do the differences in principal strain thresholds between anisotropic and isotropic models affect the assessment of concussion risk in various brain regions?
For the anisotropic equivalent strain measure, strain in the corpus callosum shows the highest correlation with injury scriptstyle(mathrmp1.41mathrme-004 for the Wald test). This is interesting when considering the capability of AESM to predict TBI because the anisotropic measure seems to better correlate with mechanic...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the anisotropic equivalent strain measure (AESM) enhance our understanding of traumatic brain injury (TBI) risk in anisotropic brain regions such as the corpus callosum compared to traditional strain measures?
A possibility to explain the slightly poorer performance of AESM lies in the method used to calculate the value of the coefficients that transfer tissue deformation into axonal strain (Cloots et al. 2013). A drawback in the usage of AESM is that it derives axonal stretching from tissue deformation through a set of 9 ma...
2014_58th_Stapp_final(1)_content_list_text.csv
How might the use of region-specific coefficients, rather than generalized values from previous studies like those optimized for the brainstem, improve the accuracy of axonal strain predictions in injury biomechanics studies?
Looking at the CSDM 10 , the best statistical correlation is found for the white matter (WT mathbfpmathrm. -value mathbf1.27mathrme-003) ) with a 50 risk injury level of 0.21. The logistic regression analysis shows that, in order to have the 50 of probability of concussion, 21 in volume of the white matter should be st...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the threshold for a 50% risk of concussion in white matter strain (10%) compare with the thresholds identified for other brain regions such as the corpus callosum, brainstem, midbrain, and thalamus, and what does this suggest about the variability in susceptibility to strain-induced injury across different bra...
Two head kinematics-based injury criteria are also investigated in the current study, which assess the likelihood of sustaining a head injury by providing a direct relationship between the global kinematics and the possible occurrence of injury. As a matter of fact, at present, the usage of FE models is limited in its ...
2014_58th_Stapp_final(1)_content_list_text.csv
How do head kinematics-based injury criteria compare to finite element (FE) models in terms of effectiveness and applicability for assessing head injury risk in regulatory testing?
The HIC shows a higher or similar correlation with injury than other evaluated strain-based predictors for different areas of the brain (Table 5, WT p-values). However, MAS has higher values of LH p-values and AUC, which indicate a better fit for the regression models and higher predictive power, respectively. Similar ...
2014_58th_Stapp_final(1)_content_list_text.csv
How do the Head Injury Criterion (HIC) and Maximum Angular Strain (MAS) differ in their effectiveness for predicting brain injuries, and what implications might this have for improving injury assessment models?
The poorer performance in injury analysis could be attributable to the inability of HIC to account for rotational motion, which is debated to be the primary cause for various type of TBI (Holbourn 1943). Even if angular acceleration shows a good correlation with mechanical injury data, there are other parameters that m...
2014_58th_Stapp_final(1)_content_list_text.csv
How can incorporating angular velocity measurements into head injury criteria enhance the prediction and assessment of traumatic brain injuries compared to using linear acceleration metrics like the Head Injury Criterion (HIC)?
Logistic regression has been widely used in injury analysis and results can have significant impact. However, the reliability of inferences drawn from these models depends on sample size (Bland 2000). In the present study, 58 cases, including 25 concussions and 33 injury-free cases, are analyzed. The sample is not opti...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the sample size in this study impact the reliability of strain threshold predictions for concussions using logistic regression in injury biomechanics analysis?
A crucial assumption - perhaps the most important - is that the exact velocity and direction of impact is known. It should be noted that game video footage was captured at only 30 frames per second, and that there was rarely a video frame of the actual point of impact, only one before and one after. In these cases, som...
2014_58th_Stapp_final(1)_content_list_text.csv
How do the limitations in video frame capture rates and camera positioning affect the accuracy of biomechanical assessments of impact-related injuries, and what methods can be employed to mitigate these sources of error?
Moreover, Newman et al. (2005) reported a maximum estimation error of 17 for translational accelerations, while the error for a typical reconstruction could occasionally be as high as 25 for the rotational accelerations. A major variation in acceleration could result in a significant variation of the mechanical respons...
2014_58th_Stapp_final(1)_content_list_text.csv
How do variations in linear and rotational acceleration errors impact the accuracy of brain injury reconstruction models, and what implications might this have for assessing brain strain and potential injuries in different scenarios?
The coupling between head and helmet may also affect the accuracy of the accident reconstruction. In the study it was assumed that the helmet was tight to the bald head of the dummy: however, many players prefer to wear the helmet loosely and do not fasten the strap. Also, the majority of players are not bald and the h...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the variability in head-helmet coupling, due to factors such as hair and strap tension, impact the biomechanical accuracy of predictive models for head injuries in sports?
Even if the current coarse model seems to well represent localized brain-skull motion, the low mesh density represents a severe limitation for the DTI coupling technique because it does not allow any detailed description of the distribution of the neuronal fibers in the brain. Finite elements with a mean length of 5.8;...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the coarse mesh density in current finite element models of brain-skull motion impact the precision of injury assessments, particularly in relation to the anisotropic behavior of neuronal fibers as represented by DTI data?
For the time being, a weighted averaging procedure is applied in order to reduce the loss of information. First, a correlation based on spatial coordinates is established between each final element in the model and the DTI voxels that correspond to it. Then, the normalized distance from the center of the DTI voxel to t...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the weighted averaging procedure and the correlation between spatial coordinates and DTI voxels improve the accuracy of predicting axonal strain and potential brain injury in finite element models?
KKeeping the GG value fixed at 2990 mathrmPa , tthe value of k_1 is identifiedd for differennt areas of the brain and ddifferent degreee of anisotroopy of the neeural fibers, ddepending onn the available locationns of the eexperimental ddata. Occipitall lobe, frontal and parietal loobes, thalamuus, corona raddiata and ...
2014_58th_Stapp_final(1)_content_list_text.csv
How do the varying degrees of anisotropy, as measured by the parameter k_1, affect the biomechanical response and potential injury outcomes in different regions of the brain, such as the occipital lobe versus the corpus callosum?
ABSTRACT Pedestrians are one of the least protected groups in urban traffic and frequently suffer fatal head injuries. An important boundary condition for the head is the cervical spine, and it has previously been demonstrated that neck muscle activation is important for head kinematics during inertial loading. It has...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the level of neck muscle activation impact the strain patterns observed in the brain during pedestrian-to-vehicle impacts, and what implications does this have for developing better protective measures for pedestrians in urban traffic environments?
To cope with these more complex demands and facilitate a larger span of testing conditions and parameter studies, a powerful tool that is being used increasingly often in this field is computational human body models. These can be Rigid Body Models (RBM) that are relatively fast to solve and easy to use, or Finite Elem...
2014_58th_Stapp_final(1)_content_list_text.csv
How do variations in muscle activation implemented in computational human body models, such as Rigid Body Models and Finite Element Models, impact the accuracy of injury predictions in pedestrian accidents?
Alvarez presented an activation scheme where a constant, neck muscle tonus was implemented with all the flexors at 100 and in total using over 50 of the available force generation. This tonus led to a retraction of the head, keeping it relatively stable until collision initiation mathbft_0 . The idea was to ascertain w...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the implementation of a constant neck muscle tonus, using over 50% of available force generation in neck flexors, alter the head kinematics during a collision event, and what implications does this have for assessing the potential severity and nature of head injuries?
As the pedestrian may fall towards the hood or windshield in a vast number of ways, this would result in a large variation of impact locations to the head. The muscle activation can here be used to tune a human model to hit in a specific posture or location as in injury reconstruction studies. In other studies, when a ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does muscle tonus in the neck affect head kinematics and resulting injury metrics during pedestrian accidents, and what implications might this have for developing more effective pedestrian safety systems?
Neck Model. The head and cervical spine of the THUMS was removed and replaced with the KTH head and neck model. The T1 vertebrae from both models were placed in the same position and tied with a rigid constraint. The model contains the cervical vertebrae and all important surrounding tissues as discs, facet joints and ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the modification of the neck muscle model by adjusting the discrete springs to align with anatomical landmarks in the THUMS model influence the accuracy of injury prediction in cervical spine biomechanics?
In previous studies the kinematics of the T1 vertebra were used to simulate the experiments since no body was attached to the neck (Brolin et al., 2005). In the present study, the acceleration pulse of the sled was used instead. Since the THUMS model was not in the seated position, the legs were removed and the pelvis ...
2014_58th_Stapp_final(1)_content_list_text.csv
How does constraining the motion of the pelvis and lower vertebrae in the bf Z-direction affect the biomechanical assessment of spinal injuries in frontal impacts, and what are the potential ramifications for real-world injury prediction using the THUMS model?
Startle Activation. In the previous study an activation scheme was developed that mimicked the startle reaction of a pedestrian in response to an oncoming danger, leading to a retraction of the neck but keeping the head relatively horizontal (Alvarez et al., 2013), see Figure 3. While the same activation levels were us...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the startle activation scheme affect the level of brain strain in pedestrians during collisions, and what role does muscle tension play in altering these biomechanical outcomes?
Evasive Activation. Since the startle activation was symmetric in the sagittal plane, forces would be acting in the direction of head movement relative to the T1 vertebra, as well as in the opposite direction. Another theoretically high level tonus was implemented to simulate the possibility that the pedestrians reacti...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the asymmetric muscle activation in response to head movement, relative to the T1 vertebra, influence the biomechanical assessment of potential cervical spine injuries in pedestrian-vehicle collision simulations?
For comparison, the startle activation as it was applied in the previous study (Alvarez et al., 2013) was also simulated (termed PreStartled in the remainder of this paper), i.e so that the model attained the neck posture shown in the right image in Head Model. The head model includes the scalp, the skull, the brain, t...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the use of a second-order Ogden hyperelastic constitutive model, combined with a linear viscoelastic model, improve the accuracy of injury assessment in simulations involving large elastic deformations of brain tissue?
A selectively reduced (SR) integration scheme, which uses reduced integration for the volumetric (pressure) terms and full integration for the deviatoric (shear) terms, was used for the brain tissue and the CSF. The SR scheme was used in order to avoid hourglass instabilities associated with reduced integration, and th...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the use of a selectively reduced integration scheme impact the accuracy and reliability of biomechanical models in assessing brain injuries, particularly in scenarios involving large degrees of rotation and deformation?
Based on the anatomy and physiology of the brainskull interface, the dura mater was tied to the skull using a tied- surface-to-surface contact definition in LS-DYNA (Livermore Software Technology Corporation, 2007). On account of the presence of CSF between the meningeal membranes and the brain, a sliding-only contact ...
2014_58th_Stapp_final(1)_content_list_text.csv
How might the simplification of the brain-skull interface contact definition in LS-DYNA from sliding-only to a tied interface impact the accuracy of injury predictions in biomechanical simulations?
The bulk modulus of brain tissue is roughly five to six orders of magnitude larger than the shear modulus (McElhaney et al., 1976), meaning that for a given impact it tends to deform primarily in shear. Therefore, distortional strain was used as an indicator of the risk of traumatic brain injury in the current study. T...
2014_58th_Stapp_final(1)_content_list_text.csv
How can the maximal principal Green Lagrange strain be effectively utilized to assess and predict the severity of diffuse axonal injuries and mechanical injury to the blood-brain barrier in traumatic brain injury cases?
Generalized Hood. Since the structure under the bonnet of the vehicle model is highly complex, the stiffness properties can vary greatly as a result of very small changes in impact location. Therefore, a generalized hood was created in order for the stiffness properties to be more similar among the pedestrian collision...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the generalized hood model, which utilizes differences in material layers and structural constraints, affect the outcomes of injury severity assessments in pedestrian head-form impact simulations compared to simulations using vehicle-specific hoods?
To capture a range of possible impact conditions, parameters that affect head kinematics were varied. The vehicle speed was varied since all kinematic parameters have a direct influence of the vehicle speed (Elliott et al., 2012; Tamura and Duma, 2011). The vehicle speed was selected as 40 and 20;mathrmkmh , as 70 of p...
2014_58th_Stapp_final(1)_content_list_text.csv
How do variations in pedestrian posture, specifically the Struck Leg Backward (SLB) and Struck Leg Forward (SLF) positions, influence head rotation and the potential for traumatic brain injury in vehicle collisions at different speeds?
Volunteer Sled Accelerations. The resulting head kinematics in the form of translations and rotations from the THUMS-KTH model with and without activation are plotted together with the volunteer corridors (Ewing et al. 1976, 1977) and PMHS tests (Wismans et al., 1987), and described in more detail in Appendix E. The re...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the presence or absence of musculature activation in biomechanical models influence the alignment of head kinematics with observed volunteer and PMHS test corridors in sled acceleration experiments?
Muscle Force Generation. All of the data extracted from the different studies on MVC are for male adults and are subsequently compared with the results from the MVC simulations. The results are given as the contact force on the head strap in the direction of the motion, as well as the equivalent moment about the T1 ver...
2014_58th_Stapp_final(1)_content_list_text.csv
How do variations in muscle force generation during extension and lateral flexion affect the risk of neck injuries in male adults during vehicle collisions?
The upper plot in Figure 8 shows the result from the NCAP upper leg impactor test performed on the physical version of the FE-vehicle, compared to the simulation. The result for the upper leg impactor is presented as the sum of the forces in the y-direction of the coordinate system seen in Figure 5. The forces are extr...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the difference in maximum force observed between the physical NCAP upper leg impactor test and the FE simulation influence the assessment of potential injury risk in real-world crash scenarios?
Pedestrian-to-Vehicle Collision. In Figure 9, the maximum strain value in the brain at each time point is plotted for the simulations with a vehicle speed of 20mathrmkmh . The first peaks seen in the plots, with the second reaching about 0.1 in strain, are due to the movement of the head as the pedestrian model is stru...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the observed pattern of brain strain variation during a pedestrian-to-vehicle collision correlate with potential injury outcomes, such as concussion or traumatic brain injury?
The image on the left in Figure 9 shows the results from the SLB posture, comparing the passive neck muscles with the startle and evasive activations. The head impact is at approximately 190,mathrmms , indicated with a vertical dashed line in the plots. The right image shows the same comparison but with the SLF posture...
2014_58th_Stapp_final(1)_content_list_text.csv
How do variations in neck muscle activation states, such as passive, startle, and evasive reactions, influence the biomechanical response and potential risk of injury during head impacts in different postures like SLB and SLF?
In Figure 11, maximum strain in the brain is plotted for the simulations with a vehicle speed of 40mathrmkmh .The first peaks, prior to the head impact, now reaches about 0.2 in strain. The left image shows the results from the SLB posture, comparing the passive neck muscles with the startle and evasive activations wit...
2014_58th_Stapp_final(1)_content_list_text.csv
How does the activation of neck muscles, particularly in the SLB and SLF postures, influence the maximum strain observed in the brain during pre-impact and impact phases at a vehicle speed of 40 km/h, and what implications might this have for injury prevention strategies?