| function [indx1,indx2] = getGroupedModelIndexFinal(thermalLUT_selected,calcFinalIndices) | |
| % ------------------------------------------------------------------------- | |
| % calcFinalIndices=[isDataVarPresent_Coolant,indxCell1_CP,indxCell2_CP;... | |
| % isDataVarPresent_R0,indxCell1_R0,indxCell2_R0;... | |
| % isDataVarPresent_Q,indxCell1_Q,indxCell2_Q;... | |
| % isDataVarPresent_Rleak,indxCell1_Rleak,indxCell2_Rleak;... | |
| % isDataVarPresent_AH,indxCell1_AH,indxCell2_AH]; | |
| % ------------------------------------------------------------------------- | |
| % isDataVarPresent_xx = 0 IF NO VARIATION present | |
| % Preference Order : | |
| % 1) _Coolant = ROW 1 entry | |
| % 2) _R0 = ROW 2 entry | |
| % 3) _AH = ROW 5 entry | |
| % 4) Rleak = ROW 4 entry | |
| % 5) Q = ROW 3 entry | |
| % 6) No variation present => Choose based on _Coolant entry | |
| % ------------------------------------------------------------------------- | |
| % | |
| % Copyright 2020-2026 The MathWorks, Inc. | |
| if thermalLUT_selected == 1 | |
| if calcFinalIndices(1,1) > 0 | |
| indx1=calcFinalIndices(1,2); | |
| indx2=calcFinalIndices(1,3); | |
| else | |
| if calcFinalIndices(2,1) > 0 | |
| indx1=calcFinalIndices(2,2); | |
| indx2=calcFinalIndices(2,3); | |
| else | |
| if calcFinalIndices(5,1) > 0 | |
| indx1=calcFinalIndices(5,2); | |
| indx2=calcFinalIndices(5,3); | |
| else | |
| if calcFinalIndices(4,1) > 0 | |
| indx1=calcFinalIndices(4,2); | |
| indx2=calcFinalIndices(4,3); | |
| else | |
| if calcFinalIndices(3,1) > 0 | |
| indx1=calcFinalIndices(3,2); | |
| indx2=calcFinalIndices(3,3); | |
| else | |
| % Default is Cooling Eff. variation | |
| indx1=calcFinalIndices(1,2); | |
| indx2=calcFinalIndices(1,3); | |
| end | |
| end | |
| end | |
| end | |
| end | |
| else | |
| % ThermalManagement = Thermal Ports (only lumped thermal ports work | |
| % with the Grouped Battery Model and hence Cooling eff. is NOT | |
| % checked for) | |
| % OR | |
| % ThermalManagement = None | |
| % | |
| % Worst and best cells selected based on other cell-to-cell variations | |
| if calcFinalIndices(2,1) > 0 | |
| indx1=calcFinalIndices(2,2); | |
| indx2=calcFinalIndices(2,3); | |
| else | |
| if calcFinalIndices(5,1) > 0 | |
| indx1=calcFinalIndices(5,2); | |
| indx2=calcFinalIndices(5,3); | |
| else | |
| if calcFinalIndices(4,1) > 0 | |
| indx1=calcFinalIndices(4,2); | |
| indx2=calcFinalIndices(4,3); | |
| else | |
| if calcFinalIndices(3,1) > 0 | |
| indx1=calcFinalIndices(3,2); | |
| indx2=calcFinalIndices(3,3); | |
| else | |
| % Default is Resistance variation | |
| indx1=calcFinalIndices(2,2); | |
| indx2=calcFinalIndices(2,3); | |
| end | |
| end | |
| end | |
| end | |
| end | |