Download data/Scripts_Data/Battery_Management_System_plot1state.m from introvoyz041/Battery-Pack-Model-Simscape: direct link, hf CLI and curl.
- Browser
- Download file 1.88 kB
-
https://huggingface.co/datasets/introvoyz041/Battery-Pack-Model-Simscape/resolve/main/data/Scripts_Data/Battery_Management_System_plot1state.m
- Command line
-
hf download hf://datasets/introvoyz041/Battery-Pack-Model-Simscape/data/Scripts_Data/Battery_Management_System_plot1state.m
-
curl -L -o Battery_Management_System_plot1state.m https://huggingface.co/datasets/introvoyz041/Battery-Pack-Model-Simscape/resolve/main/data/Scripts_Data/Battery_Management_System_plot1state.m
1.88 kB
| % Code to plot simulation results from Battery_Management_System | |
| %% Plot Description: | |
| % | |
| % Copyright 2021-2026 The MathWorks, Inc. | |
| % Generate new simulation results if they don't exist or if they need to be updated | |
| if ~exist('simlog_Battery_Management_System', 'var') | |
| sim('Battery_Management_System') | |
| end | |
| % Reuse figure if it exists, else create new figure | |
| if ~exist('h1_Battery_Management_System', 'var') || ... | |
| ~isgraphics(h1_Battery_Management_System, 'figure') | |
| h1_Battery_Management_System = figure('Name', 'Battery_Management_System'); | |
| end | |
| figure(h1_Battery_Management_System) | |
| clf(h1_Battery_Management_System) | |
| % Get simulation results | |
| simlog_t=simlog_Battery_Management_System.DC.Current_Source.i.series.time; | |
| simlog_I=simlog_Battery_Management_System.DC.Current_Source.i.series.values; | |
| simlog_minSOC_error=Battery_Management_System_Scope{5}.Values.Data(:,1)... | |
| -Battery_Management_System_Scope{5}.Values.Data(:,2); | |
| simlog_maxSOC_error=Battery_Management_System_Scope{6}.Values.Data(:,1)... | |
| -Battery_Management_System_Scope{6}.Values.Data(:,2); | |
| % Plot results | |
| simlog_handles(1) = subplot(3, 1, 1); | |
| plot(simlog_t, simlog_I, 'LineWidth', 1) | |
| title('Battery Pack Current') | |
| ylabel('Current (A)') | |
| xlabel('Time (s)') | |
| % | |
| simlog_handles(2) = subplot(3, 1, 2); | |
| plot(simlog_t, abs(simlog_minSOC_error),'r') | |
| title('Error in min. State of Charge (actual~prediction) prediction') | |
| ylabel('actual~prediction') | |
| xlabel('Time (s)') | |
| ylim([-0.05 0.05]) | |
| % | |
| simlog_handles(3) = subplot(3, 1, 3); | |
| plot(simlog_t, abs(simlog_maxSOC_error),'r') | |
| title('Error in max. State of Charge (actual~prediction) prediction') | |
| ylabel('actual~prediction') | |
| xlabel('Time (s)') | |
| ylim([-0.05 0.05]) | |
| % Remove temporary variables | |
| clear simlog_t simlog_SOC simlog_I simlog_minSOC_error simlog_maxSOC_error | |
| clear simlog_handles Battery_Management_System_Scope | |