| % Code to plot simulation results from Battery_Pack_Thermal_Management | |
| %% Plot Description: | |
| % | |
| % Copyright 2020-2026 The MathWorks, Inc. | |
| % Generate new simulation results if they don't exist or if they need to be updated | |
| if ~exist('simlog_Battery_Pack_Thermal_Management', 'var') || ... | |
| pm_simlogNeedsUpdate(simlog_Battery_Pack_Thermal_Management) | |
| sim('Battery_Pack_Thermal_Management') | |
| end | |
| % Reuse figure if it exists, else create new figure | |
| if ~exist('h1_Battery_Pack_Thermal_Management', 'var') || ... | |
| ~isgraphics(h1_Battery_Pack_Thermal_Management, 'figure') | |
| h1_Battery_Pack_Thermal_Management = figure('Name', 'Battery_Pack_Thermal_Management'); | |
| end | |
| figure(h1_Battery_Pack_Thermal_Management) | |
| clf(h1_Battery_Pack_Thermal_Management) | |
| % Get simulation results | |
| sim_t = simlog_Battery_Pack_Thermal_Management.Current_Source.i.series.time; | |
| dc_curr = simlog_Battery_Pack_Thermal_Management.Current_Source.i.series.values; | |
| pump_pow = simlog_Battery_Pack_Thermal_Management.Power.P.series.values; | |
| SOC1 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_1.outputCellSOC.series.values; | |
| SOC2 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_2.outputCellSOC.series.values; | |
| SOC3 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_3.outputCellSOC.series.values; | |
| SOC4 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_4.outputCellSOC.series.values; | |
| SOC5 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_5.outputCellSOC.series.values; | |
| SOC6 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_6.outputCellSOC.series.values; | |
| SOC7 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_7.outputCellSOC.series.values; | |
| SOC8 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_8.outputCellSOC.series.values; | |
| T1 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_1.outputCellTemp.series.values; | |
| T2 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_2.outputCellTemp.series.values; | |
| T3 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_3.outputCellTemp.series.values; | |
| T4 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_4.outputCellTemp.series.values; | |
| T5 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_5.outputCellTemp.series.values; | |
| T6 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_6.outputCellTemp.series.values; | |
| T7 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_7.outputCellTemp.series.values; | |
| T8 = simlog_Battery_Pack_Thermal_Management.Battery_Pack.Module_8.outputCellTemp.series.values; | |
| % Plot results | |
| simlog_handles(1) = subplot(4, 1, 1); | |
| plot(sim_t, dc_curr, 'LineWidth', 1) | |
| grid on | |
| title('Battery Pack Current') | |
| ylabel('Current (A)') | |
| xlabel('Time (s)') | |
| % | |
| simlog_handles(2) = subplot(4, 1, 2); | |
| plot(sim_t, pump_pow, 'LineWidth', 1) | |
| grid on | |
| title('Pump Power') | |
| ylabel('Power (W)') | |
| xlabel('Time (s)') | |
| % | |
| simlog_handles(3) = subplot(4, 1, 3); | |
| plot(sim_t, T1, 'LineWidth', 1) | |
| hold on | |
| plot(sim_t, T2, 'LineWidth', 1) | |
| plot(sim_t, T3, 'LineWidth', 1) | |
| plot(sim_t, T4, 'LineWidth', 1) | |
| plot(sim_t, T5, 'LineWidth', 1) | |
| plot(sim_t, T6, 'LineWidth', 1) | |
| plot(sim_t, T7, 'LineWidth', 1) | |
| plot(sim_t, T8, 'LineWidth', 1) | |
| hold off | |
| grid on | |
| title('Cell Temperatures') | |
| ylabel('Temperature (K)') | |
| xlabel('Time (s)') | |
| % | |
| simlog_handles(4) = subplot(4, 1, 4); | |
| plot(sim_t, SOC1, 'LineWidth', 1) | |
| hold on | |
| plot(sim_t, SOC2, 'LineWidth', 1) | |
| plot(sim_t, SOC3, 'LineWidth', 1) | |
| plot(sim_t, SOC4, 'LineWidth', 1) | |
| plot(sim_t, SOC5, 'LineWidth', 1) | |
| plot(sim_t, SOC6, 'LineWidth', 1) | |
| plot(sim_t, SOC7, 'LineWidth', 1) | |
| plot(sim_t, SOC8, 'LineWidth', 1) | |
| hold off | |
| grid on | |
| title('Cell SOC') | |
| ylabel('SOC (-)') | |
| xlabel('Time (s)') | |
| linkaxes(simlog_handles, 'x') | |
| % Remove temporary variables | |
| clear sim_t pump_pow dc_curr T1 T2 T3 T4 T5 T6 T7 T8 | |
| clear SOC1 SOC2 SOC3 SOC4 SOC5 SOC6 SOC7 SOC8 | |
| clear simlog_handles | |