| %% Parameters for ev_thermal_management | |
| % | |
| % Copyright 2020-2026 The MathWorks, Inc. | |
| % Configure scenario (see code): | |
| % (1) drive cycle, set <user_selection> == 1 | |
| % (2) cool down, set <user_selection> == 2 | |
| % (3) cold weather, set <user_selection> == 3 | |
| user_selection = 3; | |
| if user_selection == 1 | |
| scenario = 'drive cycle'; | |
| elseif user_selection == 2 | |
| scenario = 'cool down'; | |
| elseif user_selection == 3 | |
| scenario = 'cold weather'; | |
| else | |
| scenario = 'none'; | |
| end | |
| % | |
| %% Initial conditions | |
| cabin_p_init = 0.101325; % [MPa] Initial air pressure | |
| cabin_T_init = 30; % [degC] Initial air temperature | |
| cabin_RH_init = 0.4; % Initial relative humidity | |
| cabin_CO2_init = 4e-4; % Initial CO2 mole fraction | |
| coolant_p_init = 0.101325; % [MPa] Initial coolant pressure | |
| coolant_T_init = 30; % [degC] Initial coolant temperature | |
| refrigerant_p_init = 0.8; % [MPa] Initial refrigerant pressure | |
| refrigerant_alpha_init = 0.6; % Initial refrigerant vapor void fraction | |
| battery_T_init = 30; % [degC] Initial battery temperature | |
| battery_SOC_init = 0.95; % [-] Initial state of charge of the battery | |
| %% Vehicle Cabin | |
| cabin_duct_area = 0.04; % [m^2] Air duct cross-sectional area | |
| %% Liquid Coolant System | |
| coolant_pipe_D = 0.019; % [m] Coolant pipe diameter | |
| coolant_channel_D = 0.0092; % [m] Coolant jacket channels diameter | |
| coolant_valve_displacement = 0.0063; % [m] Max spool displacement | |
| coolant_valve_offset = 0.001; % [m] Orifice opening offset when spool is neutral | |
| coolant_valve_D_ratio_max = 0.95; % Max orifice diameter to pipe diameter ratio | |
| coolant_valve_D_ratio_min = 1e-3; % Leakage orifice diameter to pipe diameter ratio | |
| pump_displacement = 0.02; % [l/rev] Coolant pump volumetric displacement | |
| pump_speed_max = 1000; % [rpm] Coolant pump max shaft speed | |
| coolant_tank_volume = 2.5 / 2; % [l] Volume of each coolant tank | |
| coolant_tank_area = 0.11^2; % [m^2] Area of one side of coolant tank | |
| %% Refrigeration System | |
| refrigerant_pipe_D = 0.01; % [m] Refrigerant pipe diameter | |
| % Compressor map table | |
| compressor_p_ratio_LUT = [0; 1; 4.28795213348131; 7.57590426696263; 10.8638564004439; 14.1518085339253]; % Pressure ratio | |
| compressor_rpm_LUT = [0, 1800, 3600]; % [rpm] Shaft speed | |
| compressor_mdot_corr_LUT = [ | |
| 0, 0, 0; | |
| 0, 0.0114121796814927, 0.0228243593629856; | |
| 0, 0.00855913476111960, 0.0171182695222391; | |
| 0, 0.00570608984074638, 0.0114121796814927; | |
| 0, 0.00285304492037319, 0.00570608984074636; | |
| 0, 0, 0]; % [kg/s] Corrected mass flow rate | |
| %% Radiator | |
| radiator_L = 0.6; % [m] Overall radiator length | |
| radiator_W = 0.015; % [m] Overall radiator width | |
| radiator_H = 0.2; % [m] Overal radiator height | |
| radiator_N_tubes = 25; % Number of coolant tubes | |
| radiator_tube_H = 0.0015; % [m] Height of each coolant tube | |
| radiator_fin_spacing = 0.002; % Fin spacing | |
| radiator_wall_thickness = 1e-4; % [m] Material thickness | |
| radiator_wall_conductivity = 240; % [W/m/K] Material thermal conductivity | |
| radiator_gap_H = (radiator_H - radiator_N_tubes*radiator_tube_H) / (radiator_N_tubes - 1); % [m] Height between coolant tubes | |
| radiator_air_area_flow = (radiator_N_tubes - 1) * radiator_L * radiator_gap_H; % [m^2] Air flow cross-sectional area | |
| radiator_air_area_primary = 2 * (radiator_N_tubes - 1) * radiator_W * (radiator_L + radiator_gap_H); % [m^2] Primary air heat transfer surface area | |
| radiator_N_fins = (radiator_N_tubes - 1) * radiator_L / radiator_fin_spacing; % Total number of fins | |
| radiator_air_area_fins = 2 * radiator_N_fins * radiator_W * radiator_gap_H; % [m^2] Total fin surface area | |
| radiator_tube_Leq = 2*(radiator_H + 20*radiator_tube_H*radiator_N_tubes); % [m] Additional equivalent tube length for losses due to manifold and splits | |
| fan_area = 0.25 * 2; % [m^2] Fan flow area (2 fans) | |
| %% Condenser | |
| condenser_L = 0.63 * 2; % [m] Overall condenser length (2 condensers) | |
| condenser_W = 0.015; % [m] Overall condenser width | |
| condenser_H = 0.39; % [m] Overall condenser height | |
| condenser_N_tubes = 40; % Number of refrigerant tubes | |
| condenser_N_tube_channels = 12; % Number of channels per refrigerant tube | |
| condenser_tube_H = 0.002; % [m] Height of each refrigerant tube | |
| condenser_fin_spacing = 0.0005; % [m] Fin spacing | |
| condenser_wall_thickness = 1e-4; % [m] Material thickness | |
| condenser_wall_conductivity = 240; % [W/m/K] Material thermal conductivity | |
| condenser_gap_H = (condenser_H - condenser_N_tubes*condenser_tube_H) / (condenser_N_tubes - 1); % [m] Height between refrigerant tubes | |
| condenser_air_area_flow = (condenser_N_tubes - 1) * condenser_L * condenser_gap_H; % [m^2] Air flow cross-sectional area | |
| condenser_air_area_primary = 2 * (condenser_N_tubes - 1) * condenser_W * (condenser_L + condenser_gap_H); % [m^2] Primary air heat transfer surface area | |
| condenser_N_fins = (condenser_N_tubes - 1) * condenser_L / condenser_fin_spacing; % Total number of fins | |
| condenser_air_area_fins = 2 * condenser_N_fins * condenser_W * condenser_gap_H; % [m^2] Total fin surface area | |
| condenser_tube_area_webs = 2 * condenser_N_tubes * (condenser_N_tube_channels - 1) * condenser_tube_H * condenser_L; % [m^2] Total surface area of webs in refrigerant tubes | |
| condenser_tube_Leq = 2*(condenser_H + 20*condenser_tube_H*condenser_N_tubes) ... | |
| + (condenser_N_tube_channels - 1)*condenser_L*condenser_tube_H/(condenser_W + condenser_tube_H); % [m] Additional equivalent tube length for losses due to manifold, splits, and webs | |
| %% Evaporator | |
| evaporator_L = 0.63; % [m] Overall evaporator length | |
| evaporator_W = 0.015; % [m] Overall evaporator width | |
| evaporator_H = 0.2; % [m] Overall evaporator height | |
| evaporator_N_tubes = 20; % Number of refrigerant tubes | |
| evaporator_N_tube_channels = 12; % Number of channels per refrigerant tube | |
| evaporator_tube_H = 0.002; % [m] Height of each refrigerant tube | |
| evaporator_fin_spacing = 0.0005; % Fin spacing | |
| evaporator_wall_thickness = 1e-4; % [m] Material thickness | |
| evaporator_wall_conductivity = 240; % [W/m/K] Material thermal conductivity | |
| evaporator_gap_H = (evaporator_H - evaporator_N_tubes*evaporator_tube_H) / (evaporator_N_tubes - 1); % [m] Height between refrigerant tubes | |
| evaporator_air_area_flow = (evaporator_N_tubes - 1) * evaporator_L * evaporator_gap_H; % [m^2] Air flow cross-sectional area | |
| evaporator_air_area_primary = 2 * (evaporator_N_tubes - 1) * evaporator_W * (evaporator_L + evaporator_gap_H); % [m^2] Primary air heat transfer surface area | |
| evaporator_N_fins = (evaporator_N_tubes - 1) * evaporator_L / evaporator_fin_spacing; % Total number of fins | |
| evaporator_air_area_fins = 2 * evaporator_N_fins * evaporator_W * evaporator_gap_H; % [m^2] Total fin surface area | |
| evaporator_tube_area_webs = 2 * evaporator_N_tubes * (evaporator_N_tube_channels - 1) * evaporator_L * evaporator_tube_H; % [m^2] Total surface area of webs in refrigerant tubes | |
| evaporator_tube_Leq = 2*(evaporator_H + 20*evaporator_tube_H*evaporator_N_tubes); ... | |
| + (evaporator_N_tube_channels - 1)*evaporator_L*evaporator_tube_H/(evaporator_W + evaporator_tube_H); % [m] Additional equivalent tube length for losses due to manifold, splits, and webs | |
| %% Chiller | |
| chiller_N_tubes = 100; % Number of refrigerant tubes | |
| chiller_tube_L = 0.4; % [m] Length of each refrigerant tube | |
| chiller_tube_D = 0.0035; % [m] Diameter of each refrigerant tube | |
| chiller_wall_thickness = 1e-4; % [m] Material thickness | |
| chiller_wall_conductivity = 240; % [W/m/K] Material thermal conductivity | |
| chiller_N_baffles = 3; % Number of coolant baffles | |
| chiller_area_primary = chiller_N_tubes * pi * chiller_tube_D * chiller_tube_L; % [m^2] Primary heat transfer surface area | |
| chiller_area_baffles = chiller_N_baffles * 0.7 * 2 * chiller_N_tubes*((2*chiller_tube_D)^2 - pi*chiller_tube_D^2/4); % [m^2] Total surface area of coolant baffles | |
| chiller_tube_Leq = 2*0.2*chiller_tube_D*chiller_N_tubes; % [m] Additonal equivalent tube length for losses due to manifold and splits. | |
| %% Battery Pack | |
| battery_Np = 2; % Number of parallel cells in a string | |
| battery_Ns = 20; % Number of series connected strings | |
| battery_N_cells = battery_Np*battery_Ns; % Number of cells per module | |
| % | |
| battery_cell_mass = 0.125; % [kg] Cell mass | |
| battery_cell_cp = 795; % [J/kg/K] Cell specific heat | |
| battery_SOC_LUT = [0 0.1 0.25 0.5 0.75 0.9 1]'; % State of charge table breakpoints S | |
| battery_temperature_LUT = [278 293 313]; % Temperature table breakpoints T | |
| battery_capacity_Ahr = 27.8; % Battery cell capacity [Ahr] | |
| battery_Em_LUT = [ | |
| 3.4966 3.5057 3.5148 | |
| 3.5519 3.5660 3.5653 | |
| 3.6183 3.6337 3.6402 | |
| 3.7066 3.7127 3.7213 | |
| 3.9131 3.9259 3.9376 | |
| 4.0748 4.0777 4.0821 | |
| 4.1923 4.1928 4.1930]; % [V] Em open-circuit voltage vs SOC rows and T columns | |
| battery_R0_LUT = [ | |
| 0.0117 0.0085 0.0090 | |
| 0.0110 0.0085 0.0090 | |
| 0.0114 0.0087 0.0092 | |
| 0.0107 0.0082 0.0088 | |
| 0.0107 0.0083 0.0091 | |
| 0.0113 0.0085 0.0089 | |
| 0.0116 0.0085 0.0089]; % [Ohm] R0 resistance vs SOC rows and T columns | |
| battery_R1_LUT = [ | |
| 0.0109 0.0029 0.0013 | |
| 0.0069 0.0024 0.0012 | |
| 0.0047 0.0026 0.0013 | |
| 0.0034 0.0016 0.0010 | |
| 0.0033 0.0023 0.0014 | |
| 0.0033 0.0018 0.0011 | |
| 0.0028 0.0017 0.0011]; % [Ohm] R1 Resistance vs SOC rows and T columns | |
| battery_C1_LUT = [ | |
| 1913.6 12447 30609 | |
| 4625.7 18872 32995 | |
| 23306 40764 47535 | |
| 10736 18721 26325 | |
| 18036 33630 48274 | |
| 12251 18360 26839 | |
| 9022.9 23394 30606]; % [F] C1 Capacitance vs SOC rows and T columns | |
| battery_Tau1_LUT = battery_R1_LUT.*battery_C1_LUT; | |
| battery_cell_H = 0.2; % Battery cell height [m] | |
| battery_cell_T = 0.012; % Battery cell thickness [m] | |
| battery_cell_W = 0.12; % Battery cell width [m] | |
| battery_extR = 0; % Battery Module ascessory resistance (Ohm) | |
| battery_moduleCellR0_ini = ones(1,battery_N_cells); % Cell-to-cell capacity variation (-) | |
| battery_moduleCellSOC_ini = battery_SOC_init*ones(1,battery_N_cells); % Cell-to-cell initial SOC variation (-) | |
| battery_moduleCellT_ini = (battery_T_init+273)*ones(1,battery_N_cells);% Cell-to-cell initial temperature variation (K) | |
| battery_moduleExtHeat = zeros(1,battery_N_cells); % Cell-to-cell external heat flux variation (W) | |
| % Cell-to-cell variation in Resistance R0 | |
| battery_moduleCellAhr_ini01 = ones(1,battery_N_cells); % Cell-to-cell resistance variation (-) for 1st Module | |
| battery_moduleCellAhr_ini02 = ones(1,battery_N_cells); % Cell-to-cell resistance variation (-) for 2nd Module | |
| battery_moduleCellAhr_ini03 = ones(1,battery_N_cells); % Cell-to-cell resistance variation (-) for 3rd Module | |
| battery_moduleCellAhr_ini04 = ones(1,battery_N_cells); % Cell-to-cell resistance variation (-) for 4th Module | |
| sampleDistribution160=load('num160Data.txt'); | |
| battery_moduleCellAhr_ini01(1:battery_N_cells)=sort(sampleDistribution160(1:battery_N_cells)'); | |
| battery_moduleCellAhr_ini02(1:battery_N_cells)=sort(sampleDistribution160(battery_N_cells+1:2*battery_N_cells)'); | |
| battery_moduleCellAhr_ini03(1:battery_N_cells)=sort(sampleDistribution160(2*battery_N_cells+1:3*battery_N_cells)'); | |
| battery_moduleCellAhr_ini04(1:battery_N_cells)=sort(sampleDistribution160(3*battery_N_cells+1:4*battery_N_cells)'); | |
| % | |
| battery_moduleSideHTC = 1; % Heat transfer coefficient on module sides | |
| battery_thermal_K1 = 0.8; % Battery cell (through-plane) thermal conductivity [W/mK] | |
| battery_thermal_K2 = 800; % Battery cell (in-plane) thermal conductivity [W/mK] | |
| % | |
| %% Parameter changes as per selected secnario | |
| subsys = [bdroot '/Scenario']; | |
| if user_selection == 1 | |
| % Switch signal builder group | |
| %signalbuilder([subsys '/Vehicle Speed [km//hr]'], 'ActiveGroup', 1) % Drive cycle | |
| set_param([subsys '/Vehicle Speed'], 'ActiveScenario', 'Drive_Cycle') % Drive cycle | |
| % Update constant block values | |
| set_param([subsys '/Pressure [MPa]'], 'Value', '0.101325') % [MPa] Environment pressure | |
| set_param([subsys '/Temperature [degC]'], 'Value', '30') % [degC] Environment temperature | |
| set_param([subsys '/Relative Humidity'], 'Value', '0.4') % Environment relative humidity | |
| set_param([subsys '/CO2 Fraction'], 'Value', '4e-4') % Environment CO2 mole fraction | |
| set_param([subsys '/Temperature Setpoint [degC]'], 'Value', '21') % [degC] Cabin AC setpoint | |
| set_param([subsys '/AC On//Off'], 'Value', '1') % Cabin AC on or off | |
| set_param([subsys '/Recirculation On//Off'], 'Value', '0') % Cabin AC recirculation on or off | |
| set_param([subsys '/Number of Occupants'], 'Value', '1') % Number of occupants in cabin | |
| % Workspace variables | |
| cabin_p_init = 0.101325; | |
| cabin_T_init = 30; | |
| cabin_RH_init = 0.4; | |
| cabin_CO2_init = 4e-4; | |
| coolant_p_init = 0.101325; | |
| coolant_T_init = 30; | |
| refrigerant_p_init = 0.8; | |
| refrigerant_alpha_init = 0.6; | |
| battery_T_init = 30; | |
| battery_SOC_init = 0.95; | |
| % | |
| elseif user_selection == 2 | |
| % Switch signal builder group | |
| % signalbuilder([subsys '/Vehicle Speed [km//hr]'], 'ActiveGroup', 2) % Zero speed | |
| set_param([subsys '/Vehicle Speed'], 'ActiveScenario', 'Zero_Speed') % Zero speed | |
| % Update constant block values | |
| set_param([subsys '/Pressure [MPa]'], 'Value', '0.101325') % [MPa] Environment pressure | |
| set_param([subsys '/Temperature [degC]'], 'Value', '40') % [degC] Environment temperature | |
| set_param([subsys '/Relative Humidity'], 'Value', '0.5') % Environment relative humidity | |
| set_param([subsys '/CO2 Fraction'], 'Value', '4e-4') % Environment CO2 mole fraction | |
| set_param([subsys '/Temperature Setpoint [degC]'], 'Value', '21') % [degC] Cabin AC setpoint | |
| set_param([subsys '/AC On//Off'], 'Value', '1') % Cabin AC on or off | |
| set_param([subsys '/Recirculation On//Off'], 'Value', '1') % Cabin AC recirculation on or off | |
| set_param([subsys '/Number of Occupants'], 'Value', '1') % Number of occupants in cabin | |
| % Workspace variables | |
| cabin_p_init = 0.101325; | |
| cabin_T_init = 40; | |
| cabin_RH_init = 0.5; | |
| cabin_CO2_init = 4e-4; | |
| coolant_p_init = 0.101325; | |
| coolant_T_init = 40; | |
| refrigerant_p_init = 1; | |
| refrigerant_alpha_init = 0.76; | |
| battery_T_init = 40; | |
| battery_SOC_init = 0.95; | |
| % | |
| elseif user_selection == 3 | |
| % Switch signal builder group | |
| %signalbuilder([subsys '/Vehicle Speed [km//hr]'], 'ActiveGroup', 1) % Drive cycle | |
| set_param([subsys '/Vehicle Speed'], 'ActiveScenario', 'Drive_Cycle') % Drive cycle | |
| % Update constant block values | |
| set_param([subsys '/Pressure [MPa]'], 'Value', '0.101325') % [MPa] Environment pressure | |
| set_param([subsys '/Temperature [degC]'], 'Value', '-10') % [degC] Environment temperature | |
| set_param([subsys '/Relative Humidity'], 'Value', '0.5') % Environment relative humidity | |
| set_param([subsys '/CO2 Fraction'], 'Value', '4e-4') % Environment CO2 mole fraction | |
| %set_param([subsys '/Temperature Setpoint [degC]'], 'Value', '21') % [degC] Cabin AC setpoint | |
| set_param([subsys '/AC On//Off'], 'Value', '0') % Cabin AC on or off | |
| set_param([subsys '/Recirculation On//Off'], 'Value', '1') % Cabin AC recirculation on or off | |
| set_param([subsys '/Number of Occupants'], 'Value', '1') % Number of occupants in cabin | |
| cabin_p_init = 0.101325; | |
| cabin_T_init = -10; | |
| cabin_RH_init = 0.5; | |
| cabin_CO2_init = 4e-4; | |
| coolant_p_init = 0.101325; | |
| coolant_T_init = -10; | |
| refrigerant_p_init = 0.2; | |
| refrigerant_alpha_init = 0.15; | |
| battery_T_init = -10; | |
| battery_SOC_init = 0.95; | |
| % | |
| else | |
| % Error | |
| end | |
| battery_moduleCellSOC_ini = battery_SOC_init*ones(1,battery_N_cells); | |
| battery_moduleCellT_ini = (battery_T_init+273)*ones(1,battery_N_cells); | |
| % Update Scenario subsystem tag for annotation | |
| set_param(subsys, 'Tag', scenario) | |