Download data/DWSIM.Automation.Tests/Module1.vb from introvoyz041/Dwsim: direct link, hf CLI and curl.
- Browser
- Download file 2.46 kB
-
https://huggingface.co/datasets/introvoyz041/Dwsim/resolve/main/data/DWSIM.Automation.Tests/Module1.vb
- Command line
-
hf download hf://datasets/introvoyz041/Dwsim/data/DWSIM.Automation.Tests/Module1.vb
-
curl -L -o Module1.vb https://huggingface.co/datasets/introvoyz041/Dwsim/resolve/main/data/DWSIM.Automation.Tests/Module1.vb
2.46 kB
| Module Module1 | |
| Sub Main() | |
| 'create automation manager | |
| Dim interf As New DWSIM.Automation.Automation2() | |
| Dim sim As Interfaces.IFlowsheet | |
| sim = interf.CreateFlowsheet() | |
| 'load Cavett's Problem simulation file | |
| sim = interf.LoadFlowsheet("samples" & IO.Path.DirectorySeparatorChar & "Cavett's Problem.dwxml") | |
| 'set a listener to catch solver messages | |
| 'sim.SetMessageListener(Sub(msg As String) | |
| ' Console.WriteLine(msg) | |
| ' End Sub) | |
| 'use CAPE-OPEN interfaces to manipulate objects | |
| Dim feed, vap_out, liq_out As CapeOpen.ICapeThermoMaterialObject | |
| feed = sim.GetFlowsheetSimulationObject("2") | |
| vap_out = sim.GetFlowsheetSimulationObject("8") | |
| liq_out = sim.GetFlowsheetSimulationObject("18") | |
| 'mass flow rate values in kg/s | |
| Dim flows(3) As Double | |
| flows(0) = 170.0# | |
| flows(1) = 180.0# | |
| flows(2) = 190.0# | |
| flows(3) = 200.0# | |
| 'vapor and liquid flows | |
| Dim vflow, lflow As Double | |
| For i = 0 To flows.Length - 1 | |
| 'set feed mass flow | |
| feed.SetProp("totalflow", "overall", Nothing, "", "mass", New Double() {flows(i)}) | |
| 'calculate the flowsheet (run the simulation) | |
| Console.WriteLine("Running simulation with F = " & flows(i) & " kg/s, please wait...") | |
| interf.CalculateFlowsheet2(sim) | |
| 'check for errors during the last run | |
| If sim.Solved = False Then | |
| Console.WriteLine("Error solving flowsheet: " & sim.ErrorMessage) | |
| End If | |
| 'get vapor outlet mass flow value | |
| vflow = vap_out.GetProp("totalflow", "overall", Nothing, "", "mass")(0) | |
| 'get liquid outlet mass flow value | |
| lflow = liq_out.GetProp("totalflow", "overall", Nothing, "", "mass")(0) | |
| 'display results | |
| Console.WriteLine("Simulation run #" & (i + 1) & " results:" & vbCrLf & "Feed: " & flows(i) & ", Vapor: " & vflow & ", Liquid: " & lflow & " kg/s" & vbCrLf & "Mass balance error: " & (flows(i) - vflow - lflow) & " kg/s") | |
| Next | |
| interf.SaveFlowsheet2(sim, "/Users/Daniel/Desktop/savefile.dwxmz") | |
| Console.WriteLine("Finished OK! Press any key to close.") | |
| Console.ReadKey() | |
| End Sub | |
| End Module | |