File size: 9,007 Bytes
eb1a751 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 | # -*- coding: utf-8 -*-
# hensmith: Heat Exchanger Network Synthesis, Modeling, Integration,
# Thermodynamics, and Heuristics
# Copyright (C) 2020-, Sarang Bhagwat <sarangbhagwat.developer@gmail.com>
#
# This module is under the UIUC open-source license. See
# github.com/BioSTEAMDevelopmentGroup/hensmith/blob/master/LICENSE.txt
# for license details.
"""Tutorial chapter 04 (docs/source/tutorial/04_configuring.rst): configuring a
HeatExchangerNetwork -- sweeping the minimum approach temperature to expose the
utility/capital trade-off, splitting streams where the targets need it
(``stream_splitting=True``), scoping the analysis with ``ignored=``, and
synthesizing a larger ten-stream system (the ten-stream case of the regression
suite, inlined here rather than imported from ``tests``). Regions between
``# [start:x]`` / ``# [end:x]`` are literalinclude'd by the page; everything
else is plumbing.
python docs/_demo_src/examples/ch04_configuring.py
"""
import sys
import pathlib
sys.path.insert(0, str(pathlib.Path(__file__).resolve().parents[1]))
import _common # noqa: E402 (sets NUMBA_DISABLE_JIT / DISABLE_PREFERENCES, Agg)
from _common import capturing, save
# [start:imports]
import matplotlib.pyplot as plt
import biosteam as bst
from hensmith import HeatExchangerNetwork
from hensmith.hxn_synthesis import problem_table
# [end:imports]
# [start:helpers]
def utility_hx(ID, T, P, phase, T_out, rigorous=None, **flow):
"""A simulated HXutility acting as one process stream (kmol/hr flows)."""
s = bst.Stream(ID + '_in', T=T, P=P, phase=phase, units='kmol/hr', **flow)
if rigorous is None: rigorous = phase == 'g'
hx = bst.HXutility(ID, ins=s, T=T_out, rigorous=rigorous)
hx.simulate()
return hx
def boiling_hx(ID, T, P, T_out, **flow):
"""A cold liquid stream heated past its bubble point (rigorous VLE)."""
return utility_hx(ID, T, P, 'l', T_out, rigorous=True, **flow)
# [end:helpers]
def main():
# [start:system]
import biosteam as bst
from hensmith import HeatExchangerNetwork
bst.settings.set_thermo(['Water', 'Methanol', 'Glycerol'], cache=True)
bst.main_flowsheet.set_flowsheet('quickstart')
feed1 = bst.Stream('feed1', flow=(8000, 100, 25))
feed2 = bst.Stream('feed2', flow=(10000, 1000, 10))
D1 = bst.ShortcutColumn('D1', ins=feed1,
outs=('distillate', 'bottoms_product'),
LHK=('Methanol', 'Water'),
y_top=0.99, x_bot=0.01, k=2,
is_divided=True)
D1_H1 = bst.HXutility('D1_H1', ins=D1.outs[1], T=300)
D1_H2 = bst.HXutility('D1_H2', ins=D1.outs[0], T=300)
F1 = bst.Flash('F1', ins=feed2, outs=('vapor', 'liquid'), V=0.9, P=101325)
HXN = HeatExchangerNetwork('HXN', T_min_app=5.)
sys = bst.System.from_units('sys', units=[D1, D1_H1, D1_H2, F1, HXN])
sys.simulate()
# [end:system]
with capturing('ch04_sweep'):
# [start:sweep]
rows = []
for T_min_app in (2., 5., 10., 15., 20., 30.):
HXN.T_min_app = T_min_app
sys.simulate()
rows.append((T_min_app, HXN.actual_heat_util_load, HXN.actual_cool_util_load,
HXN.installed_costs['Heat exchangers'], len(HXN.new_HXs),
dict(HXN.synthesis_info)))
print('T_min_app heating cooling added installed pinch process status')
print('[K] [kJ/hr] [kJ/hr] cost [USD] [K] exchangers')
for T, heat, cool, cost, n, info in rows:
pinch_T = info['plan_targets']['pinch_T'] # shifted scale
status = info['status']
if status != 'mer': # process-side hot utility above the MER target
status += f" (+{info['Q_hot'] - info['Q_hot_target']:.3g} kJ/hr)"
print(f'{T:<9.0f} {heat:<9.4g} {cool:<9.4g} {cost:<15.4g} {pinch_T:<8.2f} {n:<11d} {status}')
# [end:sweep]
# [start:sweep_plot]
T = [r[0] for r in rows]
fig, (ax1, ax2) = plt.subplots(1, 2, figsize=(9, 3.6))
ax1.plot(T, [r[1] / 1e6 for r in rows], 'o-', color='#d62728', label='heating utility')
ax1.plot(T, [r[2] / 1e6 for r in rows], 's-', color='#2e6db4', label='cooling utility')
ax1.set_xlabel('T_min_app [K]'); ax1.set_ylabel('utility load [GJ/hr]')
ax1.legend(fontsize=8); ax1.grid(alpha=0.3)
ax2.plot(T, [r[3] / 1e6 for r in rows], 'o-', color='k')
ax2.set_xlabel('T_min_app [K]'); ax2.set_ylabel('added installed cost [MUSD]'); ax2.grid(alpha=0.3)
fig.tight_layout()
# [end:sweep_plot]
save(fig, 'tutorial_04_T_min_app_sweep.png')
plt.close(fig)
with capturing('ch04_ignored'):
# [start:ignored]
HXN.T_min_app = 5.
HXN.ignored = [D1_H1] # leave the bottoms cooler out of the analysis
sys.simulate()
print(f'streams in the network: {len(HXN.stream_life_cycles)}')
print(f'heating utility: {HXN.original_heat_util_load:.4g} -> {HXN.actual_heat_util_load:.4g} kJ/hr')
print(f'cooling utility: {HXN.original_cool_util_load:.4g} -> {HXN.actual_cool_util_load:.4g} kJ/hr')
HXN.ignored = None
# [end:ignored]
with capturing('ch04_splitting'):
# [start:splitting]
HXN.T_min_app = 15. # the sweep's first best-effort network
for stream_splitting in (False, True):
HXN.stream_splitting = stream_splitting
sys.simulate()
info = HXN.synthesis_info
print(f'stream_splitting={stream_splitting}: {info["status"]}, '
f'{len(HXN.new_HXs)} process exchangers, '
f'{HXN.installed_costs["Heat exchangers"]:.4g} USD added installed cost')
print('splitters:', [u.ID for u in HXN.new_splitters])
print('mixers: ', [u.ID for u in HXN.new_mixers])
print('process exchangers:', [hx.ID for hx in HXN.new_HXs])
print(info['splits'])
print(HXN.stream_life_cycles[3])
HXN.stream_splitting = False
HXN.T_min_app = 5.
# [end:splitting]
with capturing('ch04_ten_streams'):
# [start:ten_streams]
bst.settings.set_thermo(['Water', 'Ethanol'], cache=True)
bst.main_flowsheet.set_flowsheet('ten_streams')
units = [utility_hx('H1', 355., 101325., 'g', 320., Ethanol=300.),
utility_hx('H2', 420., 5e5, 'g', 340., Water=150.),
utility_hx('H3', 395., 5e5, 'l', 330., Water=1000.),
utility_hx('H4', 370., 101325., 'l', 310., Ethanol=700.),
utility_hx('H5', 380., 101325., 'g', 372.5, Water=100.), # partial condensation
utility_hx('C1', 300., 101325., 'l', 360., Water=2000.),
boiling_hx('C2', 330., 101325., 380., Water=200.),
boiling_hx('C3', 320., 101325., 352., Ethanol=400.),
utility_hx('C4', 310., 101325., 'l', 345., Water=400., Ethanol=400.),
utility_hx('C5', 340., 101325., 'l', 390., Water=600.)]
HXN10 = HeatExchangerNetwork('HXN', T_min_app=5.)
sys10 = bst.System.from_units('sys10', units=[*units, HXN10])
sys10.simulate()
hus = HXN10.original_heat_utils
streams_inlet = [hu.unit.ins[0].copy() for hu in hus]
streams_quenched = [hu.unit.outs[0].copy() for hu in hus]
for s in streams_quenched: s.vle(H=s.H, P=s.P)
table = problem_table(streams_inlet, streams_quenched, [hu.duty < 0 for hu in hus], 5.)
print(f'process exchangers: {len(HXN10.new_HXs)}')
print(f'hot utility: target {table.hot_util_load:.4g}, network {HXN10.actual_heat_util_load:.4g} kJ/hr')
print(f'cold utility: target {table.cold_util_load:.4g}, network {HXN10.actual_cool_util_load:.4g} kJ/hr')
# Those loads are utility-side (duty = unit_duty / heat transfer
# efficiency); the targets are process-side enthalpy differences, so
# sum the process-side duties of the network's utility exchangers too.
new_hus = [hu for hx in HXN10.new_HX_utils for hu in hx.heat_utilities]
heat = sum(hu.unit_duty for hu in new_hus if hu.unit_duty > 0)
cool = -sum(hu.unit_duty for hu in new_hus if hu.unit_duty < 0)
print(f'hot utility, process side: target {table.hot_util_load:.4g}, network {heat:.4g} kJ/hr')
print(f'cold utility, process side: target {table.cold_util_load:.4g}, network {cool:.4g} kJ/hr')
print(f'energy balance error: {HXN10.energy_balance_percent_error:.2g} %')
print(f"synthesis status: {HXN10.synthesis_info['status']}")
fig, ax = HXN10.plot_pinch_diagram()
# [end:ten_streams]
save(fig, 'tutorial_04_ten_streams_pinch_diagram.png')
plt.close(fig)
assert len(HXN10.new_HXs) == 10, len(HXN10.new_HXs)
assert HXN10.synthesis_info['status'] == 'mer'
assert HXN10.actual_heat_util_load >= table.hot_util_load * (1 - 1e-3)
if __name__ == '__main__':
main()
|