| Anatomy of a synthesized network | |
| ================================ | |
| :doc:`01_quickstart` reported what the network saved and :doc:`02_pinch_analysis` | |
| where those targets come from. Neither looked at the network itself. This | |
| chapter opens it: the flowsheet and ``System`` the facility builds for its own | |
| exchangers, the naming that makes them readable, the per-stream life cycles | |
| that record which exchangers each stream passes through and in what order, the | |
| per-stream pinch temperatures that split the design into its two sides, the | |
| options of the pinch diagram, and the cost and utility accounting the facility | |
| reports. | |
| Every number and figure below is output of the code shown on this page. The | |
| system built here is chapter 1's build repeated verbatim, so this page runs on | |
| its own. | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:imports] | |
| :end-before: # [end:imports] | |
| :dedent: | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:system] | |
| :end-before: # [end:system] | |
| :dedent: | |
| The network flowsheet | |
| --------------------- | |
| By default, the facility never touches the streams or exchangers of the system | |
| it integrates. Everything it synthesizes -- stream copies, process exchangers, | |
| utility exchangers -- is created in a flowsheet of its own, and gathered into a | |
| ``System`` of its own. | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:flowsheet] | |
| :end-before: # [end:flowsheet] | |
| :dedent: | |
| .. literalinclude:: /_generated/ch03_flowsheet.txt | |
| :language: text | |
| ``HXN.HXN_flowsheet`` is that flowsheet, a ``bst.Flowsheet`` named after the | |
| system it belongs to, ``sys.ID + '_HXN'`` -- here ``sys_HXN``. It is created | |
| each time the facility synthesizes a network, and its registries are cleared | |
| before synthesis, so the network's IDs neither collide with the original | |
| flowsheet's nor accumulate across repeated simulations. | |
| ``HXN.HXN_sys`` is the ``bst.System`` built from the synthesized units. It is | |
| named after the flowsheet, ``sys_HXN``, in whose system registry it is | |
| registered -- so ``HXN.HXN_flowsheet.system.sys_HXN`` resolves to it, just as | |
| the exchangers resolve through ``HXN.HXN_flowsheet.unit``. It is an ordinary | |
| ``System`` holding the nine units listed on the third line. They are listed in | |
| the order the system simulates them, which follows the streams: after | |
| synthesis every stream's stages are rewired in series, each stage feeding the | |
| next (where a stream splits, its branches run in parallel from the splitter | |
| chain to the mixer), and the path is a topological order of those connections, ties broken | |
| by the order in which the synthesis returned the exchangers -- the process | |
| exchangers in plan order, then the utility exchangers, hot streams first. | |
| ``HX_0_2_hs`` therefore runs first: it is the first stage of both of its | |
| streams, while ``HX_1_2_hs`` has to wait for stream 2 to leave it. Where the | |
| stages of a network form a loop -- a pair of streams matched on both sides of | |
| the pinch, or two streams matched repeatedly in alternation -- the loop is | |
| torn at a recycle stream and converged by the system's own fixed-point | |
| solver. | |
| The IDs carry the whole topology. A process exchanger is an ``HXprocess`` named | |
| ``HX_<cold>_<hot>_hs`` when it lies above the pinch, in the hot-side design, and | |
| ``HX_<hot>_<cold>_cs`` when it lies below the pinch, in the cold-side design -- | |
| note that the two orders differ: a cold-side exchanger names its hot stream | |
| first, a hot-side one its cold stream first, and in both the first number is | |
| the stream at port 0. When the same two streams are matched more than once on | |
| the same side, the second and later exchangers carry a suffix, ``_2``, | |
| ``_3``, ..., in the order the hot stream meets them (``HX_3_2_cs_2``, say). A | |
| utility exchanger is an ``HXutility`` named ``Util_<index>_hs`` for a cold | |
| stream, which is finished by a hot utility above the pinch, and | |
| ``Util_<index>_cs`` for a hot stream, which is finished by a cold utility below | |
| it. The indices are stream indices: positions in the rearranged utility list of | |
| :func:`~hensmith.synthesize_network`, cold streams first and then hot ones, as | |
| described in :doc:`02_pinch_analysis`. The stream copies are named after the | |
| exchanger they touch, ``s_<index>__<exchanger>`` on the way in and | |
| ``<exchanger>__s_<index>`` on the way out. This network has no stream split; | |
| one synthesized with ``stream_splitting=True`` can also hold, for each split, | |
| a chain of ``Splitter`` units named ``Split_<index>_<hs|cs>`` (with ``_b<c>`` | |
| for the chain's element *c* >= 2, and ``_<n>`` before it for a stream's | |
| *n*-th split on that side) and a ``Mixer`` named ``Mix_<index>_<hs|cs>`` where | |
| the branches re-join, both in ``HXN_sys`` and listed in ``HXN.new_splitters`` | |
| and ``HXN.new_mixers`` (:doc:`04_configuring` shows one). | |
| All four process exchangers of this network end in ``_hs``: every match lies | |
| above the pinch, which is the same fact as the pinch diagram of | |
| :doc:`01_quickstart` showing all four connectors to the right of the pinch | |
| line. Below the pinch there is nothing to design: no cold stream needs heat | |
| there (stream 1 enters exactly at the pinch temperature and stream 0 above | |
| it, as the pinch temperatures below show), so the only stream below it, hot | |
| stream 2, is finished by its cooler. | |
| .. code-block:: python | |
| HXN.HXN_sys.diagram() | |
| .. figure:: /_static/images/examples/tutorial_03_hxn_flowsheet_light.png | |
| :figclass: only-light | |
| :width: 720 | |
| :alt: Flowsheet of the synthesized quickstart network: nine units, the four process heat exchangers HX_0_2_hs, HX_1_2_hs, HX_1_4_hs and HX_1_3_hs drawn as two-inlet nodes in a chain feeding the utility exchangers Util_0_hs and Util_1_hs (heating), Util_2_cs (cooling), and the grey zero-duty nodes Util_3_cs and Util_4_cs. | |
| The synthesized network as its own flowsheet, ``sys_HXN``. The four | |
| two-inlet nodes are the process exchangers; each takes one cold and one hot | |
| stream copy and passes both on. The five single-inlet nodes are the utility | |
| exchangers that finish each stream: ``Util_0_hs`` and ``Util_1_hs`` are | |
| heating, ``Util_2_cs`` is cooling, and ``Util_3_cs`` and ``Util_4_cs`` are | |
| drawn grey because they carry no utility at all -- their inlet and outlet | |
| enthalpies are equal, 2.47e+06 and 7.18e+05 kJ/hr, so streams 3 and 4 are | |
| brought to their outlet states by process heat exchange alone. The stream | |
| names show the wiring: ``s_1__HX_1_2_hs`` enters ``HX_1_2_hs`` carrying | |
| stream 1, and ``HX_1_2_hs__s_1`` leaves it and enters ``HX_1_4_hs``. | |
| .. figure:: /_static/images/examples/tutorial_03_hxn_flowsheet_dark.png | |
| :figclass: only-dark | |
| :width: 720 | |
| :alt: Flowsheet of the synthesized quickstart network: nine units, the four process heat exchangers HX_0_2_hs, HX_1_2_hs, HX_1_4_hs and HX_1_3_hs drawn as two-inlet nodes in a chain feeding the utility exchangers Util_0_hs and Util_1_hs (heating), Util_2_cs (cooling), and the grey zero-duty nodes Util_3_cs and Util_4_cs. | |
| The synthesized network as its own flowsheet, ``sys_HXN``. The four | |
| two-inlet nodes are the process exchangers; each takes one cold and one hot | |
| stream copy and passes both on. The five single-inlet nodes are the utility | |
| exchangers that finish each stream: ``Util_0_hs`` and ``Util_1_hs`` are | |
| heating, ``Util_2_cs`` is cooling, and ``Util_3_cs`` and ``Util_4_cs`` are | |
| drawn grey because they carry no utility at all -- their inlet and outlet | |
| enthalpies are equal, 2.47e+06 and 7.18e+05 kJ/hr, so streams 3 and 4 are | |
| brought to their outlet states by process heat exchange alone. The stream | |
| names show the wiring: ``s_1__HX_1_2_hs`` enters ``HX_1_2_hs`` carrying | |
| stream 1, and ``HX_1_2_hs__s_1`` leaves it and enters ``HX_1_4_hs``. | |
| Stream life cycles | |
| ------------------ | |
| A flowsheet of nine units says what exists; it does not say, for one stream, | |
| what happens to it. That is what a :class:`~hensmith.StreamLifeCycle` records. | |
| The facility builds one per stream after synthesis, aligned with | |
| ``HXN.original_heat_exchangers``, and stores them in | |
| ``HXN.stream_life_cycles``. | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:life_cycles] | |
| :end-before: # [end:life_cycles] | |
| :dedent: | |
| .. literalinclude:: /_generated/ch03_life_cycles.txt | |
| :language: text | |
| A life cycle has the attributes ``index``, the stream's index; ``name``, | |
| ``s_<index>``; ``cold``, ``True`` for a heated stream and ``False`` for a cooled | |
| one; and ``life_cycle``, the list of stages. It is recovered from IDs alone: | |
| each exchanger ID is parsed -- ``HX_<a>_<b>_<hs|cs>``, with an optional | |
| ``_<n>`` suffix, or ``Util_<a>_<hs|cs>`` -- the first number being the stream | |
| at port 0 and the second the stream at port 1, so a stream index is matched | |
| exactly and never as a substring of another index. The stages are then sorted | |
| by inlet enthalpy, ascending for a cold stream and descending for a hot one, | |
| which is flow direction in both cases since a cold stream gains enthalpy as it | |
| goes and a hot stream loses it (ties, which only stages without duty can | |
| produce, put the stream's first side of the pinch first and its utility | |
| last). A stream split with ``stream_splitting=True`` changes this only where | |
| it splits: its life cycle also holds the stream's splits (``splits``) and the | |
| port where the whole stream enters (``entry``, the first splitter if it splits | |
| at its inlet), and the stages of its branches, which run in parallel, follow | |
| the stages before the split branch by branch, each in flow order and marked | |
| with its branch and flow fraction. | |
| Read stream 1, the longest life cycle here: it passes ``HX_1_2_hs``, | |
| ``HX_1_4_hs`` and ``HX_1_3_hs`` and then its utility exchanger ``Util_1_hs``, | |
| its enthalpy rising 0, 5.05e+06, 5.08e+06, 2.3e+07 and finally 2.79e+08 kJ/hr. | |
| Its first exchanger is the match the pinch design method asks for: stream 1 | |
| enters exactly at the pinch temperature, and ``HX_1_2_hs`` pairs it there with | |
| stream 2, the only hot stream that reaches the pinch, from which the planner | |
| builds the hot-side design outward. Stream 2 runs the other way, 4.52e+07 to | |
| 8.12e+06 to 3.07e+06 kJ/hr through two process exchangers and then to | |
| 1.14e+06 kJ/hr through ``Util_2_cs``. Each | |
| stage's outlet enthalpy is the next stage's inlet enthalpy because the facility | |
| rewires the units after synthesis, making each stage's outlet stream the inlet | |
| of the following stage. Streams 3 and 4 end on a stage whose inlet and outlet | |
| enthalpies are equal, 2.47e+06 and 7.18e+05 kJ/hr: their utility exchangers | |
| have nothing left to do. | |
| One stage on its own: | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:stage] | |
| :end-before: # [end:stage] | |
| :dedent: | |
| .. literalinclude:: /_generated/ch03_stage.txt | |
| :language: text | |
| A ``LifeStage`` holds only two things, ``unit`` and ``index``; everything else | |
| is a property read from the unit when accessed. ``index`` is the position of | |
| this stream in the exchanger's ``ins`` and ``outs`` -- 0 or 1 for an | |
| ``HXprocess``, always 0 for an ``HXutility``. Here it is 0, because a hot-side | |
| process exchanger is constructed with its cold stream first. ``s_in`` and | |
| ``s_out`` are ``unit.ins[index]`` and ``unit.outs[index]``, and ``H_in`` and | |
| ``H_out`` are their enthalpies, so a life cycle always reflects the current | |
| state of the network rather than a snapshot taken at synthesis. This stage | |
| takes stream 1 from 0 to 5.051e+06 kJ/hr. | |
| Per-stream pinch temperatures | |
| ----------------------------- | |
| The pinch analysis produces three arrays indexed like the life cycles, which | |
| the facility stores as ``HXN.inlet_Ts``, ``HXN.outlet_Ts`` and | |
| ``HXN.pinch_Ts``. The first two are each stream's inlet temperature and its | |
| quenched outlet temperature (:doc:`02_pinch_analysis`). The third is the | |
| temperature at which a stream crosses the process pinch on its own scale, | |
| where it passes from the cold-side design into the hot-side design. It is | |
| reported for information: the synthesizer cuts every stream at the pinch on | |
| the stream's temperature-enthalpy curve itself, and ``pinch_Ts`` summarizes | |
| where that cut lies. | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:pinch_Ts] | |
| :end-before: # [end:pinch_Ts] | |
| :dedent: | |
| .. literalinclude:: /_generated/ch03_pinch_Ts.txt | |
| :language: text | |
| The process pinch of this system is a single shifted temperature, 298.15 K | |
| (:doc:`02_pinch_analysis`), which stands for two real ones: 25.0 °C for cold | |
| streams and, ``T_min_app`` higher, 30.0 °C for hot streams. Each stream is then | |
| classified against the pinch temperature of its own kind. | |
| - A stream that reaches the pinch is cut there, and its ``pinch_T`` is the | |
| pinch temperature of its kind. Stream 2 crosses it, 98.2 to 26.8 °C, and | |
| stream 1 enters exactly at it, 25.0 °C; they are cut at 30.0 and 25.0 °C | |
| respectively. | |
| - A stream whose outlet stops short of the pinch never reaches it, and its | |
| ``pinch_T`` is its own *outlet* temperature: it lies wholly on one side, and | |
| the cut is a formality at its far end. Streams 3 and 4 are hot streams that | |
| cool only to 64.9 and 64.8 °C, far above the 30.0 °C hot-stream pinch, and | |
| those outlet temperatures are exactly what ``pinch_Ts`` reports for them. | |
| - A stream whose *inlet* is already past the pinch is likewise not cut, and | |
| its ``pinch_T`` is its inlet temperature. Stream 0 is a cold stream entering | |
| at 33.2 °C, above the 25.0 °C cold-stream pinch, so its ``pinch_T`` is | |
| 33.2 °C. | |
| That last clause also catches isothermal and non-monotone streams -- a stream | |
| whose outlet lies on the wrong side of its inlet for the sign of its duty, such | |
| as a cold stream whose equilibrium outlet ends up cooler than it entered. | |
| These get ``pinch_T = T_in`` too, but only as a label. The synthesis treats | |
| them as the problem table does, as a point load: their whole duty sits at their | |
| outlet temperature, on whichever side of the pinch that temperature lies (and, | |
| exactly at the pinch, on the side the problem table's cascade assigns the | |
| point loads there), and such a stream enters its first process exchanger in | |
| the equilibrium state at its inlet enthalpy. | |
| Reading the pinch diagram | |
| ------------------------- | |
| :func:`~hensmith.plot_pinch_diagram` draws the life cycles above. Called as | |
| ``HXN.plot_pinch_diagram``, the facility supplies the life cycles, the inlet | |
| and outlet temperatures, the hot-side and cold-side exchanger lists, its | |
| ``Qmin`` and the original exchangers, and forwards ``file`` and every other | |
| keyword argument. Those remaining arguments are: | |
| ``show_units``, ``show_auxiliary_units`` and ``show_stream_IDs`` | |
| The three parts of each stream's label, built from its *original* heat | |
| exchanger and joined as ``<unit> - <auxiliary> (<inlet stream ID>)``: | |
| respectively the ID of the unit owning that exchanger, the name of the | |
| exchanger within its owner when it is an auxiliary one (``condenser`` and | |
| the like), and the ID of that exchanger's inlet stream. All three default | |
| to ``True``; with all three off no label is drawn and the original | |
| exchangers are not needed, while turning any of them on without those | |
| exchangers raises ``ValueError``. | |
| ``show_legend`` | |
| Adds a legend of the six symbols -- cold stream, hot stream, process heat | |
| exchange, hot utility, cold utility, pinch -- below the axes. | |
| ``ax`` | |
| Draws into a ``matplotlib`` axes provided by the caller instead of creating | |
| a figure; the figure returned is then the one that axes belongs to. | |
| ``file`` and ``dpi`` | |
| Save the figure to a path, at the given resolution. | |
| Turning off the labels and the legend leaves the quantitative skeleton of the | |
| diagram: | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:minimal] | |
| :end-before: # [end:minimal] | |
| :dedent: | |
| .. figure:: /_static/images/examples/tutorial_03_pinch_diagram_minimal.png | |
| :class: white-bg | |
| :width: 100% | |
| :alt: Minimal pinch diagram of the synthesized quickstart network, drawn into a caller-provided axes with the stream labels and the legend suppressed: two blue cold streams indexed 0 and 1 running left to right above three red hot streams indexed 2, 3 and 4 running right to left, T and H columns on both sides reading 33.2 °C and 5.38E6 kJ/hr to 99.5 °C and 6.92E7 kJ/hr for stream 0, four vertical process-exchanger connectors with boxed duties between the streams, a dashed pinch line with all four connectors on its hot side, and the Cold side and Hot side captions along the bottom. | |
| The same network as the pinch diagram of :doc:`01_quickstart`, with | |
| ``show_stream_IDs=False`` and ``show_legend=False`` -- and the two unit-label | |
| options off as well -- drawn into an axes created by the caller. Only the | |
| stream annotations and the legend are gone: the ``T`` and ``H`` columns on | |
| both sides remain, and so do the boxed exchanger duties in the ``ΔH`` row, | |
| the bold stream index at the inlet of each stream, the dashed pinch line and | |
| the ``Cold side`` and ``Hot side`` captions. The columns read off the life | |
| cycles above: stream 1 enters at 25.0 °C with 0.00E0 kJ/hr and leaves at | |
| 95.9 °C with 2.79E8 kJ/hr, and the first connector it meets carries the | |
| 5.05E6 kJ/hr of its first stage. The four duties are the same four as in | |
| :doc:`01_quickstart`. | |
| Exchanger columns are ordered independently on each side of the pinch, by | |
| ``_order_exchanger_columns``. Every stream's stage order is a chain of | |
| precedence constraints between the exchangers it meets -- reversed for hot | |
| streams, which are drawn right to left -- and a topological sort of that graph | |
| (Kahn's algorithm, ties broken by the order in which the synthesis returned the | |
| exchangers, the plan order from the pinch outward) lays them out so that every | |
| stream meets its exchangers in flow direction. That is why stream 1 reads its | |
| three connectors left to right in exactly the order of its life cycle. | |
| Constraints that contradict each other, which would require some stream to | |
| flow backwards, cannot be satisfied by any ordering; the given order is then | |
| used unchanged. | |
| Energy balance and cost accounting | |
| ---------------------------------- | |
| What the facility reports about itself is one consistency check and a set of | |
| differences. | |
| .. literalinclude:: /../_demo_src/examples/ch03_network_anatomy.py | |
| :language: python | |
| :start-after: # [start:accounting] | |
| :end-before: # [end:accounting] | |
| :dedent: | |
| .. literalinclude:: /_generated/ch03_accounting.txt | |
| :language: text | |
| ``energy_balance_percent_error`` compares the heat the synthesized network | |
| moves with the heat the original exchangers moved. The numerator is twice the | |
| absolute duty of every new process exchanger -- twice, because each process | |
| match takes that heat off one stream and puts it onto another -- plus the | |
| process-side duty of the new utility exchangers, each agent's ``duty`` | |
| multiplied by its ``heat_transfer_efficiency``. The denominator is the same | |
| product summed over the original utilities. The ratio less one, times 100, is | |
| the reported percentage: -1.8e-11 % here, which is round-off. | |
| The tolerance it is checked against, ``acceptable_energy_balance_error``, is a | |
| *fraction*, not a percentage: the class attribute is ``0.02``, that is 2 %, and | |
| the constructor argument of the same name defaults to ``None``, meaning that | |
| the class value is kept. The check is on the absolute error. Exceeding it warns | |
| with a ``RuntimeWarning`` naming the error and the tolerance, or raises a | |
| ``RuntimeError`` instead if the class attribute ``raise_energy_balance_error`` | |
| is set to ``True``. | |
| The costs are differences, clipped at zero. ``original_purchase_costs`` is the | |
| purchase cost of each *original* exchanger, one entry per stream, 3.365e+05 USD | |
| in total here; ``new_purchase_costs_HXp`` and ``new_purchase_costs_HXu`` are | |
| the same for the synthesized process and utility exchangers, 4.734e+05 and | |
| 2.095e+05 USD. The facility's own ``purchase_costs['Heat exchangers']`` -- and | |
| its identical ``baseline_purchase_costs`` entry -- is ``max(0, new - original)`` | |
| over those three sums, 4.734e+05 + 2.095e+05 - 3.365e+05 = 3.464e+05 USD. Its | |
| ``installed_costs['Heat exchangers']`` is formed exactly the same way from the | |
| installed costs of the same exchangers rather than their purchase costs, and | |
| is the larger figure here, 1.112e+06 USD. Clipping at zero means a network | |
| whose exchangers happen to be cheaper than the ones they replace is reported as | |
| adding nothing rather than as a capital credit; and if the synthesis produced | |
| no process exchangers at all, both entries are set to zero and the facility | |
| reports no utilities either. | |
| The utilities are differences too. ``original_utility_costs`` holds the | |
| original heat utilities summed by agent -- reversed in sign, since they are the | |
| very objects that were negated to form the difference -- and | |
| ``new_utility_costs`` holds the new utility exchangers' utilities summed by | |
| agent. ``HXN.heat_utilities`` is the sum of the two, that is new - original, | |
| which is why every cost printed above is negative: -388.8 USD/hr of low | |
| pressure steam, -210.7 USD/hr of chilled water and -5.976 USD/hr of cooling | |
| water are savings. The duties carry the sign convention of their agent, so the | |
| steam duty is negative, -6.324e+07 kJ/hr, while the chilled and cooling water | |
| duties are positive, 4.214e+07 and 1.794e+07 kJ/hr, because cooling duties are | |
| negative to begin with and a positive difference again means less of them. | |
| Setting ``replace_unit_heat_utilities=True`` moves this reporting onto the | |
| process units instead, as :doc:`04_configuring` describes. | |
| Where to next | |
| ------------- | |
| - :doc:`04_configuring` -- the constructor options of the facility, what | |
| ``T_min_app`` and ``ignored`` change, and a ten-stream network. | |
| - :doc:`../concepts` -- the pinch concepts, the MER planner, and what | |
| a synthesized network is and is not guaranteed to be. | |
| - :doc:`../API/api` -- the full API reference. | |