Datasets:
Download tasks/mr/L4_4ch/task.json from neutral-123/MedImageOSWorld: direct link, hf CLI and curl.
- Browser
- Download file 2.4 kB
-
https://huggingface.co/datasets/neutral-123/MedImageOSWorld/resolve/main/tasks/mr/L4_4ch/task.json
- Command line
-
hf download hf://datasets/neutral-123/MedImageOSWorld/tasks/mr/L4_4ch/task.json
-
curl -L -o task.json https://huggingface.co/datasets/neutral-123/MedImageOSWorld/resolve/main/tasks/mr/L4_4ch/task.json
2.4 kB
| { | |
| "schema": "medimageosworld-public-task-v1", | |
| "task_id": "L4_4ch", | |
| "modality": "MR", | |
| "level": "L3", | |
| "goal_text": "A two-chamber localizer has been acquired. Accurately prescribe the initial four-chamber long-axis localizer; its row is open.\n\nANATOMICAL CRITERIA:\nBoth ventricles and both atria should be represented in one long-axis plane without foreshortening the LV apex. The LV apex and midpoint of the LV–LA junction should be in plane. Where available, basal ventricular SAX anatomy should support a four-chamber orientation across the interventricular septum toward the RV free wall, rather than an oblique two-chamber or outflow-tract view. The plane should be approximately perpendicular to the SAX planes and consistent with any acquired long-axis references.\nThese XCAT reference images are diastolic; valve leaflets may not be visible. Use the midpoint of the LV–LA junction and the LV apex to define the LV long axis. A short-axis plane is perpendicular to that long axis.\n\nENDPOINT: The requested prescription has been successfully submitted. Return done at that point; later workline rows are outside this task. Completion of later acquisitions is not required.", | |
| "budgets": { | |
| "max_steps": 60, | |
| "wall_budget_s": 3600.0 | |
| }, | |
| "observation": { | |
| "mode": "pixels_only", | |
| "viewport_px": [ | |
| 1600, | |
| 1000 | |
| ], | |
| "notes": "Screenshot of the console each step plus one history image and a compact text history of the last four actions; the full text operator manual; geometry tasks also get reference images of a correctly planned view from a different phantom. The model may request zoomed crops of the current screenshot." | |
| }, | |
| "allowed_actions": [ | |
| "click", | |
| "double_click", | |
| "drag", | |
| "move", | |
| "scroll", | |
| "key", | |
| "type", | |
| "wait", | |
| "done", | |
| "abstain" | |
| ], | |
| "initial_setup": "The two-chamber localizer has been acquired; the 4-Chamber Localizer row is open in the editor. Any editable draft prescription starts from a per-episode randomised position and orientation.", | |
| "visualization": { | |
| "start_png": false, | |
| "success_png": false, | |
| "success_gif": false, | |
| "note": "visualization pending: this start state is built from upstream acquisitions whose geometry comes from private reference planning that does not exist for the public development phantom", | |
| "status": "visualization pending" | |
| } | |
| } | |