Datasets:

ArXiv:
License:
tristan-deep commited on
Commit
0ba3ced
·
verified ·
1 Parent(s): a7e1ded

waterloo-muscle: restructure the data card to the common layout

Browse files
Files changed (1) hide show
  1. waterloo-muscle/README.md +36 -42
waterloo-muscle/README.md CHANGED
@@ -1,4 +1,5 @@
1
  ---
 
2
  pretty_name: UW-MuscleRF
3
  license: cc-by-4.0
4
  task_categories:
@@ -22,39 +23,23 @@ size_categories:
22
 
23
  ![Reconstructed cineloop from Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5](assets/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.gif)
24
 
25
- Cine loop of [`Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5`](https://huggingface.co/datasets/nvidia/OpenH-RF/blob/main/waterloo-muscle/data/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5), reconstructed from the raw
26
- channel data with the `pipeline.yaml` in this folder.
27
-
28
- `zea` renders it straight from the Hub:
29
-
30
- ```bash
31
- zea process \
32
- --dataset hf://nvidia/OpenH-RF/waterloo-muscle/data/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5 \
33
- --config hf://nvidia/OpenH-RF/waterloo-muscle/pipeline.yaml \
34
- --n-frames 1 \
35
- --save-as png
36
- ```
37
-
38
- Swap `--n-frames 1 --save-as png` for `--save-as gif` to get the cine loop.
39
-
40
-
41
- Dataset consisting of raw RF data and speed of sound measurements acquired in an in vivo speed of sound study conducted by LITMUS @ University of Waterloo.
42
 
43
  ## Dataset Description
44
 
45
- This is a dataset consisting of 18,720 raw RF frames (plane wave; 580,320 frame-transmits) and associated SoS measurements using a programmable research scanner configured for high frame rate imaging. We used a rigorous image collection protocol based on landmarking according to bone markers to ensure image consistency. This data was collected as part of the following study:
46
 
47
  D. Xiao, P. De La Torre, M. Saif El Nasr, A. J. Y. Chee, M. Mourtzakis, and A. C. H. Yu, “LivePulse-Echo Speed-of-Sound Estimation for Quality Assessment of Large Muscles in Humans,”Ultrasound in Medicine & Biology, vol. 51, no. 11, pp. 1925–1935, Nov. 2025.
48
 
49
-
50
  ## Dataset Contributor(s)
51
 
52
- Hassan Nahas, Di Xiao, Pat de la Torre, Adrian J.Y. Chee, Marina Mourtzakis, Alfred C.H. Yu
53
-
54
- Correspondence emails:
55
- hassan.nahas@uwaterloo.ca
56
- di.xiao@uwaterloo.ca
57
- alfred.yu@uwaterloo.ca
 
58
 
59
  ## Dataset Creation Date
60
 
@@ -62,10 +47,7 @@ alfred.yu@uwaterloo.ca
62
 
63
  ## License / Terms of Use
64
 
65
- [Creative Commons Attribution 4.0 International (CC BY 4.0)](https://creativecommons.org/licenses/by/4.0/legalcode.en).
66
-
67
- This human study was approved by the University of Waterloo’s Human Research Ethics Board (ORE #44778). All included data was acquired from participants who provided both written and verbal consent prior to participating in the study regarding public data sharing.
68
-
69
 
70
  ## Intended Usage
71
 
@@ -81,13 +63,31 @@ The algorithm for global speed of sound estimation can be found here:
81
  D. Xiao, P. D. l. Torre and A. C. H. Yu, "Real-Time Speed-of-Sound Estimation In Vivo via Steered Plane Wave Ultrasound," in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 71, no. 6, pp. 673-686, June 2024, doi: 10.1109/TUFFC.2024.3395490.
82
 
83
 
84
- - **Acquisition system:**
85
- Raw RF data was acquired from the US4R-Lite research scanner (US4US, Warsaw, Poland), equipped with an L14-5 linear array. For a subset of acquisitions, a through-transmission SoS estimation was made using a custom setup consisting of two single-element Olympus transducers (C567; Olympus; Tokyo, Japan).
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
86
 
87
  ## Dataset Format
88
 
89
- Submitted in the [`zea` file format](https://zea.readthedocs.io/en/latest/)
90
- (one HDF5 file per acquisition).
 
91
 
92
  Per-sample contents of the converted HDF5:
93
 
@@ -107,8 +107,8 @@ Per-sample contents of the converted HDF5:
107
  | `custom/baecke_sport_index` | `[1]` | float32 | /5 | Baecke sport activity score |
108
  | `custom/baecke_leisure_index` | `[1]` | float32 | /5 | Baecke leisure activity score |
109
  | `custom/baecke_score` | `[1]` | float32 | /15 | Total baecke score |
110
- All `coordinates` arrays are per-pixel Cartesian positions in metres, last axis
111
- `[x, y, z]` (y = 0 for these 2-D maps).
112
 
113
  ## Dataset Quantification
114
 
@@ -134,13 +134,7 @@ All 1,248 HDF5 files are uploaded; current stored size and format version are re
134
 
135
  ## Data Validation
136
 
137
- [`reconstruct.py`](reconstruct.py) builds a `zea.Pipeline` of DAS beamforming →
138
- envelope detection → normalization → log-compression **in code** and reconstructs
139
- a B-mode directly from `raw_data` — showing the raw-to-image flow without any
140
- config file. It also saves the pipeline to [`pipeline.yaml`](pipeline.yaml) as a
141
- shareable recipe. Comparing the reconstruction against the stored B-mode is a
142
- sanity check that the acquisition parameters and probe geometry are recorded
143
- correctly, and serves as a reproducible reference reconstruction.
144
 
145
  ## Known Issues
146
  - Scan.sound_speed uses default 1540 m/s used for computing tx delays as was done during acquisition. This is different from the estimated global speed of sound which is currently stored as a custom element.
 
1
  ---
2
+ name: waterloo-muscle
3
  pretty_name: UW-MuscleRF
4
  license: cc-by-4.0
5
  task_categories:
 
23
 
24
  ![Reconstructed cineloop from Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5](assets/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.gif)
25
 
26
+ *Cine loop of the relaxed left calf (lateral, longitudinal), [`data/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5`](https://huggingface.co/datasets/nvidia/OpenH-RF/blob/main/waterloo-muscle/data/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5), reconstructed from the raw channel data with the `pipeline.yaml` in this folder.*
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
27
 
28
  ## Dataset Description
29
 
30
+ 18,720 raw RF frames (plane wave; 580,320 frame-transmits) with associated speed-of-sound (SoS) measurements, acquired in vivo by LITMUS at the University of Waterloo with a programmable research scanner configured for high-frame-rate imaging. Images were collected with a rigorous protocol based on landmarking according to bone markers to ensure image consistency. This data was collected as part of the following study:
31
 
32
  D. Xiao, P. De La Torre, M. Saif El Nasr, A. J. Y. Chee, M. Mourtzakis, and A. C. H. Yu, “LivePulse-Echo Speed-of-Sound Estimation for Quality Assessment of Large Muscles in Humans,”Ultrasound in Medicine & Biology, vol. 51, no. 11, pp. 1925–1935, Nov. 2025.
33
 
 
34
  ## Dataset Contributor(s)
35
 
36
+ - Hassan Nahas <hassan.nahas@uwaterloo.ca>
37
+ - Di Xiao <di.xiao@uwaterloo.ca>
38
+ - Pat de la Torre
39
+ - Adrian J.Y. Chee
40
+ - Marina Mourtzakis
41
+ - Alfred C.H. Yu <alfred.yu@uwaterloo.ca>
42
+ - LITMUS, University of Waterloo
43
 
44
  ## Dataset Creation Date
45
 
 
47
 
48
  ## License / Terms of Use
49
 
50
+ [Creative Commons Attribution 4.0 International (CC BY 4.0)](https://creativecommons.org/licenses/by/4.0/legalcode.en). Retain attribution and identify modifications when reusing the data.
 
 
 
51
 
52
  ## Intended Usage
53
 
 
63
  D. Xiao, P. D. l. Torre and A. C. H. Yu, "Real-Time Speed-of-Sound Estimation In Vivo via Steered Plane Wave Ultrasound," in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 71, no. 6, pp. 673-686, June 2024, doi: 10.1109/TUFFC.2024.3395490.
64
 
65
 
66
+ - **Acquisition system:** Raw RF data was acquired from the US4R-Lite research scanner (US4US, Warsaw, Poland), equipped with an L14-5 linear array. For a subset of acquisitions, a through-transmission SoS estimation was made using a custom setup consisting of two single-element Olympus transducers (C567; Olympus; Tokyo, Japan).
67
+
68
+ ## Processing the Dataset
69
+
70
+ The acquisitions can be processed with the `pipeline.yaml` definition in this folder and the [zea library](https://github.com/tue-bmd/zea).
71
+
72
+ `zea` streams the data from the Hugging Face Hub and processes it according to the pipeline. You can try it out with the following command:
73
+
74
+ ```bash
75
+ zea process \
76
+ --dataset hf://nvidia/OpenH-RF/waterloo-muscle/data/Acq_p35_Calf_left_calf_lateral_longitudinal_relaxed_pressure.hdf5 \
77
+ --config hf://nvidia/OpenH-RF/waterloo-muscle/pipeline.yaml \
78
+ --n-frames 1 \
79
+ --save-as png
80
+ ```
81
+
82
+ Alternatively, you can use the `reconstruct.py` [script](https://github.com/open-h/OpenH-RF/blob/main/datasets/waterloo-muscle/reconstruct.py) as provided in the [OpenH-RF GitHub repository](https://github.com/open-h/OpenH-RF).
83
+
84
+ Swap `--n-frames 1 --save-as png` for `--save-as gif` to get the cine loop. In the script, `ZEA_FILE` and `FRAME` at the top select what is reconstructed.
85
 
86
  ## Dataset Format
87
 
88
+ [zea v0.1.6](https://github.com/tue-bmd/zea)
89
+
90
+ Submitted in the [`zea` file format](https://zea.readthedocs.io/en/latest/) (one HDF5 file per acquisition).
91
 
92
  Per-sample contents of the converted HDF5:
93
 
 
107
  | `custom/baecke_sport_index` | `[1]` | float32 | /5 | Baecke sport activity score |
108
  | `custom/baecke_leisure_index` | `[1]` | float32 | /5 | Baecke leisure activity score |
109
  | `custom/baecke_score` | `[1]` | float32 | /15 | Total baecke score |
110
+
111
+ All `coordinates` arrays are per-pixel Cartesian positions in metres, last axis `[x, y, z]` (y = 0 for these 2-D maps).
112
 
113
  ## Dataset Quantification
114
 
 
134
 
135
  ## Data Validation
136
 
137
+ `reconstruct.py` builds a `zea.Pipeline` of DAS beamforming → envelope detection → normalization → log-compression **in code** and reconstructs a B-mode directly from `raw_data` — showing the raw-to-image flow without any config file. It also saves the pipeline to `pipeline.yaml` as a shareable recipe. Comparing the reconstruction against the stored B-mode is a sanity check that the acquisition parameters and probe geometry are recorded correctly, and serves as a reproducible reference reconstruction.
 
 
 
 
 
 
138
 
139
  ## Known Issues
140
  - Scan.sound_speed uses default 1540 m/s used for computing tx delays as was done during acquisition. This is different from the estimated global speed of sound which is currently stored as a custom element.